[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-935743":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},935743,605,2,"多选题","下列关于建筑的外墙保温系统防护层的做法正确的是（ ）。",[11,15,18,21,25],{"key":12,"text":13,"correct":14},"A","某建筑采用内保温系统，保温材料为A级，未设置防护层",false,{"key":16,"text":17,"correct":14},"B","某建筑采用内保温系统，保温材料为B2级，防护层厚度10mm",{"key":19,"text":20,"correct":14},"C","某建筑采用外保温系统，保温材料为B2级，首层的防护层厚度10mm",{"key":22,"text":23,"correct":24},"D","某建筑采用外保温系统，保温材料为B1级，非首层的防护层厚度5mm",true,{"key":26,"text":27,"correct":24},"E","某建筑的屋面保温系统，采用B2级保温材料，防护层厚度10mm","DE","根据《建筑设计防火规范》GB50016-6．7．8，建筑的外墙外保温系统应采用不燃材料在其表面设置防护层，防护层厚度首层不应小于15mm，其他层不应小于5mm，C选项错误，D选项正确； 根据6．7．2—3，内保温系统应采用不燃材料做防护层。采用燃烧性能为B1级的保温材料时，防护层的厚度不应小于10mm。A选项未做防护层错误，B选项内保温系统不能使用B2级，B选项错误； 根据6．7．10，建筑的屋面外保温系统，当采用B1、B2级保温材料的外保温系统应采用不燃材料作防护层，防护层的厚度不应小于10mm，E选项正确。本题答案DE。",{"id":6,"name":31,"category":32,"favorite":33},"消防技术综合能力(一级、二级)","建筑工程",0]