[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-935702":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},935702,605,2,"多选题","某一级耐火等级影剧院观众厅，容纳人数为 2500 人，百人宽度指标为 0.65m\u002F百人，在防火检查中，下列做法符合规定的（ ）。",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","该观众厅设了 10 个疏散门，每个疏散门的宽度为 1.8m",true,{"key":16,"text":17,"correct":18},"B","观众厅内，横走道之间的座位排数为 22 排",false,{"key":20,"text":21,"correct":14},"C","纵走道之间的座位数每排为 22 个",{"key":23,"text":24,"correct":14},"D","仅一侧有纵走道的座区，每排座位数为 10 个",{"key":26,"text":27,"correct":14},"E","观众厅内疏散走道的最小净宽为 1m","ACDE","A选项，疏散门总宽度：2500人*0.65m\u002F百人=16.25m .按单股人流的宽度为 0.55m，每个疏散门三股，每个疏散门宽度至少1.65m, A 符合 BCDE选项：观众厅内疏散走道的净宽度应按每 100 人不小于0.60m 计算，且不应小于1.00m；边走道的净宽度不宜小于 0.80m。 布置疏散走道时，横走道之间的座位排数不宜超过 20排；纵走道之间的座位数：剧场、电影院、礼堂等，每排不宜超过 22个；体育馆，每排不宜超过 26个；前后排座椅的排距不小于 0.90m 时，可增加1.0 倍，但不得超过 50个；仅一侧有纵走道时，座位数应减少一半；",{"id":6,"name":31,"category":32,"favorite":33},"消防技术综合能力(一级、二级)","建筑工程",0]