[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-935385":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},935385,605,1,"单选题","下列关于厚型钢结构防火涂料的检查说法中，错误的是（ ）。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","现场选取至少五个不同的涂层部位，用测厚仪分别测量其厚度",false,{"key":16,"text":17,"correct":14},"B","涂层厚度应为测点厚度的平均值",{"key":19,"text":20,"correct":14},"C","目测涂层无开裂、脱落，则涂层外观合格",{"key":22,"text":23,"correct":24},"D","现场已施工的涂层厚度不应大于型式检验报告描述的厚度",true,"根据《消防产品现场检查判定规则》GA588—2012 6．14．2．2检查方法：防火涂料涂层外观目测无开裂、脱落；现场选取至少五个不同的涂层部位，用测厚仪分别测量其厚度。涂层厚度为测点厚度的平均值。与型式检验报告描述的厚度相比较，不低于型式检验报告描述的对应厚度，本题答案为D。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]