[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-935368":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},935368,605,2,"多选题","下列关于建筑物内建筑构件的耐火极限的说法，符合规范要求的是（ ）。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","二级耐火等级的办公建筑，其吊顶采用不燃材料，耐火极限0．10h",true,{"key":16,"text":17,"correct":14},"B","三级耐火等级的儿童游乐厅，其吊顶采用难燃材料，耐火极限0．25h",{"key":19,"text":20,"correct":21},"C","二级耐火等级建筑的门厅的吊顶，采用难燃材料，耐火极限0．25h",false,{"key":23,"text":24,"correct":21},"D","三级耐火等级建筑的走道的吊顶，采用难燃材料，耐火极限0．25h",{"key":26,"text":27,"correct":14},"E","三级耐火等级的中学教学楼，其吊顶采用不燃材料，耐火极限0．25h","ABE","根据《建筑设计防火规范》GB 50016—20145．1．8（2018年版）5．1．8，二级耐火等级建筑内采用不燃材料的吊顶，其耐火极限不限。三级耐火等级的医疗建筑、中小学校的教学建筑、老年人建筑及托儿所、幼儿园的儿童用房和儿童游乐厅等儿童活动场所的吊顶，应采用不燃材料；当采用难燃材料时，其耐火极限不应低于0．25h。二、三级耐火等级建筑内门厅、走道的吊顶应采用不燃材料。本题答案为ABE。",{"id":6,"name":31,"category":32,"favorite":33},"消防技术综合能力(一级、二级)","建筑工程",0]