[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-935086":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},935086,605,2,"多选题","（2019年真题）对某樟脑油提炼车间配置的灭火器进行检查，下列检查结果中，不符合现行国家标准要求的有（）",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","用挂钩将灭火器悬挂在墙上，挂钩最大承载力为45kg",false,{"key":16,"text":17,"correct":14},"B","灭火器套用防护外罩",{"key":19,"text":20,"correct":21},"C","灭火器铭牌朝向墙面",true,{"key":23,"text":24,"correct":21},"D","灭火器顶部高离地面距离为1.60m",{"key":26,"text":27,"correct":21},"E","配置的灭火器类型为磷酸铵盐干粉灭火器和炭酸氢钠干粉灭火器","CDE","P258-262 灭火器的铭牌应朝外，故C选项错误。 挂钩、托架的安装高度满足手提式灭火器顶部与地面距离不大于1.5m，底部与地面距离不小于0.08m。故D选项错误 磷酸铵盐干粉灭火器和炭酸氢钠干粉灭火器为不相容灭火器，不能在同一地点配置，故E选项错误",{"id":6,"name":31,"category":32,"favorite":33},"消防技术综合能力(一级、二级)","建筑工程",0]