[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-935041":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},935041,605,1,"单选题","(2017年真题)某七氟丙烷气体灭火系统防护区的灭火剂储存容器，在20℃时容器内压力为2.5MPa,50℃时的容器内压力为4.2Mpa，对该防护区灭火剂输送管道采用气压强度试验代替水压强度试验时，最小试验压力应为（??）MPa",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","3.75",false,{"key":16,"text":17,"correct":14},"B","4.62",{"key":19,"text":20,"correct":21},"C","4.83",true,{"key":23,"text":24,"correct":14},"D","6.3","《气体灭火系统施工及验收规范》(GB50263—2007)附录E．1．3规定，当水压强度试验条件不具备时，可采用气压强度试验代替。气压强度试验压力取值：二氧化碳灭火系统取80％水压强度试验压力，IG541混合气体灭火系统取10．5MPa，卤代烷1301灭火系统和七氟丙烷灭火系统取1．15倍最大工作压力。故4．2×1．15=4．83(MPa)。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]