[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-934923":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":19,"analysis":25},934923,605,1,"单选题","(2018年真题) 在消防给水系统减压阀的维护管理中，应定期对减压阀进行检测 。其中对减压阀组进行放水试验，并检测和记录减压阀前后的压力，应（ ）。",[11,15,18,22],{"key":12,"text":13,"correct":14},"A","每季度一次",false,{"key":16,"text":17,"correct":14},"B","每半年一次",{"key":19,"text":20,"correct":21},"C","每月一次",true,{"key":23,"text":24,"correct":14},"D","每年一次","《消防给水及消火栓系统技术规范规》14.0.5 减压阀的维护管理应符合下列规定： 1)每月应对减压阀组进行一次放水试验，并应检测和记录减压阀前后的压力，当不符合设计值时应采取满足系统要求的调试和维修等措施； 2)每年应对减压阀的流量和压力进行一次试验。P132-133",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]