[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-934883":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},934883,605,2,"多选题","(2018年真题)某建筑高度为98m的多功能建筑，在进行室内装修工程施工时，不符合现行国家标准要求的做法有( )。",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","对现场阻燃处理后的木质材料，每种取2m2检验燃烧性能",true,{"key":16,"text":17,"correct":14},"B","对木质材料表面进行防火涂料处理时，均匀涂刷一次防火涂料",{"key":19,"text":20,"correct":21},"C","对B1级木质材料进场进行见证取样检验",false,{"key":23,"text":24,"correct":21},"D","对木质材料进行阻燃处理时，将木质材料的含水率控制在10%以下",{"key":26,"text":27,"correct":14},"E","对木质材料表面涂刷防火涂料的用量为450g\u002F㎡","ABE","现场阻燃处理后的木质材料，每种取4㎡检验燃烧性能，木质材料表面进行防火涂料处理时，应对木质材料的所有表面进行均匀涂刷，且不应少于2次，第二次涂刷应在第一次涂层表面干后进行；涂刷防火涂料用量不应少于500g\u002F㎡，木质材料在进行阻燃处理时，木质材料含水率不应大于12%。 下列材料进场应进行见证取样检验： 1 B1级木质材料； 2 现场进行阻燃处理所使用的阻燃剂及防火涂料。P96-98",{"id":6,"name":31,"category":32,"favorite":33},"消防技术综合能力(一级、二级)","建筑工程",0]