[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-934881":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},934881,605,1,"单选题","(2017年真题)关于基层墙体与装饰层之间无空间的建筑外墙体外保温系统的做法中，不符合现行国家消防技术标准的是（??）",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","建筑高度为18m的大学教学楼， 保温系统采用燃烧性能为B1l级的保温材料",true,{"key":16,"text":17,"correct":18},"B","建筑高度为54m的底层设置商业网点的住宅， 保温系统采用燃烧性能为B1级的保温材料",false,{"key":20,"text":21,"correct":18},"C","建筑高度50m的办公楼， 保温系统采用燃烧性能为B1级的保温材料",{"key":23,"text":24,"correct":18},"D","建筑高度24m的办公楼， 保温系统采用燃烧性能为B2级的保温材料","根据《建筑设计防火规范》(GB 50016—2014)，与基层墙体、装饰层之间无空腔的建筑外墙的外保温系统，其保温材料应符合下列规定： (1)住宅建筑 (2)除住宅建筑和设置人员密集场所的建筑外的其他建筑 人员密集的室内场所保温材料采用燃烧性能为A级的保温材料，A错误。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]