[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-934814":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},934814,605,2,"多选题","（2019年真题）某二级耐火等级的服装加工厂房，地上5层，建筑高度为30m，每层建筑面积为6000㎡。该厂房首层、二层的人数均为600人，三至五层的人数均为300人。对该厂房的下列防火检查结果中，不符合现行国家标准要求的有（）",[11,15,19,22,25],{"key":12,"text":13,"correct":14},"A","疏散楼梯采用封闭楼梯间",false,{"key":16,"text":17,"correct":18},"B","第四层最大的疏散距离为60m",true,{"key":20,"text":21,"correct":14},"C","楼梯间的门采用常开乙级防火门",{"key":23,"text":24,"correct":14},"D","办公室与车间连通的门采用乙级防火门",{"key":26,"text":27,"correct":18},"E","首层外门的总净宽度为3.6m","BE","P77-82 服装加工厂房为丙类厂房，故本题中建筑为二级耐火等级的丙类高层厂房，二级丙类高层厂房疏散距离不大于40m，故B选项说法错误。 层数四层的厂房每百人疏散净宽度为1.0m\u002F百人。 首层外门的总净宽度应该按该层及以上疏散人数最多一层疏散人数计算，且该门的最小净宽度不应小于1.2m。故本体建筑首层外门总净宽度应为6m，确E选项错误",{"id":6,"name":31,"category":32,"favorite":33},"消防技术综合能力(一级、二级)","建筑工程",0]