[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-934690":3},{"question":4,"library":30},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":28,"analysis":29},934690,605,2,"多选题","（2019年真题）某二级耐火等级建筑，地上12层，地下2层，建筑总高度为3000m，一至二层为商业服务网点，三至十二层为住宅。对该建筑的下列防火检査结果中，符合现行国家标准《建筑设计防火规范》(GB50016)要求的有（）",[11,15,18,22,25],{"key":12,"text":13,"correct":14},"A","商业服务网点采用敞开楼梯间",true,{"key":16,"text":17,"correct":14},"B","商业服务网点内疏散楼梯净宽为1.1m",{"key":19,"text":20,"correct":21},"C","该楼梯间內的地下部分与地上部分在首层采用耐火极限为1.00h的隔墙分隔",false,{"key":23,"text":24,"correct":14},"D","商业服务网点内的最大疏散距离为22m",{"key":26,"text":27,"correct":21},"E","住宅的疏散楼梯采用封闭楼梯间","ABD","P48-57 建筑的地下或半地下部分与地上部分不应共用楼梯间，确需共用楼梯间时，应在首层采用耐火极限不低于2.00h的防火隔墙和乙级防火门将地下或半地下部分与地上部分的连通部位完全分隔，并应设置明显的标志。故C选项说法错误 高度大于33m的住宅建筑需要设置防烟楼梯间，故E选项说法错误",{"id":6,"name":31,"category":32,"favorite":33},"消防技术综合能力(一级、二级)","建筑工程",0]