[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-934671":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":22,"analysis":25},934671,605,1,"单选题","(2015年真题) 某机加工企业需在生产车间内设置中间仓库储存硝酸。下列设置要求中，符合规范规定的是（ ）。",[11,15,18,21],{"key":12,"text":13,"correct":14},"A","中间仓库靠外墙布置，采用防火墙及耐火极限不低于1.0h的楼板与其他部位分隔，硝酸储量不超过1昼夜用量",false,{"key":16,"text":17,"correct":14},"B","中间仓库靠外墙布置，采用耐火极限不低于2.5h的防火墙和1.5h的楼板与其他部位分隔，硝酸储量不超过1昼夜用量",{"key":19,"text":20,"correct":14},"C","中间仓库靠外墙布置，采用耐火极限不低于2.0h的防火墙和1.5h的楼板与生产部位分隔，硝酸储量不超过1昼夜用量",{"key":22,"text":23,"correct":24},"D","中间仓库靠外墙布置，采用防火墙及耐火极限不低于1.5h的不燃性楼板与其他部位分隔，硝酸储量不超过1昼夜用量",true,"硝酸的火灾危险性为乙类，根据《建筑设计防火规范》3.3.6 厂房内设置中间仓库时，应符合下列规定： 1 甲、乙类中间仓库应靠外墙布置，其储量不宜超过1昼夜的需要量； 2 甲、乙、丙类中间仓库应采用防火墙和耐火极限不低于1.50h的不燃性楼板与其他部位分隔； 3 丁、戊类中间仓库应采用耐火极限不低于2.00h的防火隔墙和1.00h的楼板与其他部位分隔； 4 仓库的耐火等级和面积应符合本规范第3.3.2条和第3.3.3条的规定。 4．中间储罐的布置",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]