[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-934665":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},934665,605,1,"单选题","(2015年真题) 某石油化工企业的厂区设置办公区、动力设备用房、消防站、甲类和乙类液体储蓄罐、液体烃储存罐、装卸设施和桶装油品堆场。下列关于工厂总平面布置的做法中，正确的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","全厂性的高架火炬设置在生产区全年最小频率风向的上风侧",true,{"key":16,"text":17,"correct":18},"B","采用架空电力线路进出厂区的总变电所布置在厂区中心",false,{"key":20,"text":21,"correct":18},"C","消防站位于生产区全年最小频率风向的上风侧",{"key":23,"text":24,"correct":18},"D","散发可燃气体的工艺装置和罐组布置在人员集中场所全年最小频率风向的下风侧","本题主要考查石油化工工厂总平面布置 全厂性的高架火炬宜位于生产区全年最小频率风向的上风侧。A正确； 采用架空电力线路进出厂区的总变电所应布置在厂区边缘。B错误； 消防站的位置宜位于生产区全年最小频率风向的下风侧。C错误； 可能散发可燃气体的工艺装置、罐组、装卸区或全厂性污水处理场等设施宜布置在人员集中场所及明火或散发火花地点的全年最小频率风向的上风侧。D错误。",{"id":6,"name":27,"category":28,"favorite":29},"消防技术综合能力(一级、二级)","建筑工程",0]