[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-9":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":667},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,9,50,2960,[13,34,46,58,70,82,92,104,116,128,146,161,176,191,206,221,230,244,256,268,283,295,310,325,340,355,370,382,394,406,418,430,442,456,468,480,492,506,518,532,541,553,565,579,591,602,614,629,641,655],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},932090,1,"单选题","（2016真题）某二级耐火等级且设置自动喷水灭火系统的旅馆，建筑高度为23.2m。“一”字形疏散内走道的东、西两端外墙上均设置采光、通风窗，在走道的两端各设置了一座疏散楼梯间，其中一座紧靠东侧外墙，另一座与西侧外墙有一定距离。建筑在该走道西侧尽端的房间门与最近一座疏散楼梯间入口门的允许最大直线距离为（）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","15",false,{"key":24,"text":25,"correct":22},"B","20",{"key":27,"text":28,"correct":22},"C","22",{"key":30,"text":31,"correct":32},"D","27.5",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},932091,"（2018真题）某耐火极限为二级的会议中心,地上5层,建筑高度为30m,第二层采用敞开式外廊作为疏散走道。该外廊的最小净宽度应为（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":32},"1.3m",{"key":24,"text":41,"correct":22},"1.1m",{"key":27,"text":43,"correct":22},"1.2m",{"key":30,"text":45,"correct":22},"1.4m",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},932092,"（2018真题）某耐火等级为二级的印刷厂房，地上5层建筑高度30m，厂房内设有自动喷水灭火系统。根据现行囯家标准《建钪设计防火规范》(GB50016)，该厂房首层任一点至最近安全出口的最大直线距离应为（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":32},"40m",{"key":24,"text":53,"correct":22},"45m",{"key":27,"text":55,"correct":22},"50m",{"key":30,"text":57,"correct":22},"60m",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},932093,"（2018真题）下列民用建筑房间中，可设一个疏散门的是（）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"老年人日间照料中心内位于走道尽端，建筑面积为 50m2 的房间",{"key":24,"text":65,"correct":22},"托儿所内位于袋形走道一侧，建筑面积为 60m2 的房间",{"key":27,"text":67,"correct":32},"教学楼内位于袋形走道一侧，建筑面积为 70m2 的教室",{"key":30,"text":69,"correct":22},"病房楼内位于两个安全出口之间，建筑面积为 80m2 的病房",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":30,"analysis":33},932094,"（2015真题）某建筑高度98.9m的大楼，使用功能为办公、宾馆、商业和娱乐。一至四层的裙房设有营业厅和办公室；地下一层夜总会疏散走道两侧和尽端设有5个卡拉OK小包间；营业厅的2个疏散门需要通过疏散走道至疏散楼梯间。该建筑按照规范要求设置消防设施。下列建筑 内疏散走道的设计中，错误的是（）",[74,76,78,80],{"key":20,"text":75,"correct":22},"办公区域疏散走道两侧的隔墙采用加气混凝土块砌筑，耐火极限为1.50h",{"key":24,"text":77,"correct":22},"宾馆区域疏散走道采用轻钢龙骨纸面石膏板吊顶，耐火极限为0.30h",{"key":27,"text":79,"correct":22},"夜总会疏散走道尽端房间房门至最近的安全出口的疏散走道长度为11m",{"key":30,"text":81,"correct":32},"裙房内营业厅的疏散门至最近的安全出口的疏散走道长度为15m",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},932095,"（2015真题）某集成电路工厂新建一个化学清洗间，建筑面积为100m2,设置一个安全出口，清洗作业使用火灾危险性为甲类的易燃液体，该清洗间同一时间内清洗操作人员应该不超过()人",[86,88,90,91],{"key":20,"text":87,"correct":22},"10",{"key":24,"text":89,"correct":32},"5",{"key":27,"text":21,"correct":22},{"key":30,"text":25,"correct":22},{"id":93,"libraryId":5,"type":15,"typeLabel":16,"stem":94,"options":95,"answer":24,"analysis":33},932096,"（2016真题）下列关于建筑内疏散楼梯间的做法中，错误的是（ ）。",[96,98,100,102],{"key":20,"text":97,"correct":22},"设置敞开式外廊的4层教学楼，每层核定人数500人，设置3部梯段净宽度均为2.00m的敞开式疏散楼梯间",{"key":24,"text":99,"correct":32},"建筑高度为15m的3层商用建筑，总建筑面积为2400㎡，一、二层为美术教室和体形训练室，三层为卡拉OK厅和舞厅，设置2座梯段净宽度均为2.00m的敞开式疏散楼梯间",{"key":27,"text":101,"correct":22},"电子厂综合装配大楼，建筑高度为31.95m，每层作业人数100人，设置2座净宽度均为1.2m的防烟楼梯间",{"key":30,"text":103,"correct":22},"建筑高度为31.9m的住宅建筑，每个单元的建筑面积为500㎡，户门至楼梯间的最大水平距离为2m，每个单元设置一座梯段净宽度为1.10m的封闭楼梯间",{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":24,"analysis":33},932097,"（2017真题）避难走道楼板及防火隔墙的最低耐火极极限分别为（ ）",[108,110,112,114],{"key":20,"text":109,"correct":22},"1.00h、2.00h",{"key":24,"text":111,"correct":32},"1.50h、3.00h",{"key":27,"text":113,"correct":22},"1.50h、2.00h",{"key":30,"text":115,"correct":22},"1.00h、3.00h",{"id":117,"libraryId":5,"type":15,"typeLabel":16,"stem":118,"options":119,"answer":20,"analysis":33},932098,"（2018真题）某建筑高度为36m的病房楼,共9层,每层建筑面枳3000m2,划分为3个护理单元。该病房避难间的下列设计方案中,正确的是（ ）",[120,122,124,126],{"key":20,"text":121,"correct":32},"将满足避难要求的监护室兼作避难间",{"key":24,"text":123,"correct":22},"在二至九层每层设置1个避难间",{"key":27,"text":125,"correct":22},"避难间的门采用乙级防火门",{"key":30,"text":127,"correct":22},"不靠外墙的避难间采用机械加压送风方式防烟",{"id":129,"libraryId":5,"type":130,"typeLabel":131,"stem":132,"options":133,"answer":145,"analysis":33},932099,2,"多选题","（2015真题）某地上18层、地下3层的建筑，每层建筑面积为1500m2,首层为大堂，二层至五层为商店，地上六层及以上各层为办公区，地下一层层高4.5米，设置设备用房和夜总会。下列关于该夜总会的消防设计中，正确的有（）。",[134,136,138,140,142],{"key":20,"text":135,"correct":32},"豪华包间的建筑面积为200m2,设置2个疏散门",{"key":24,"text":137,"correct":22},"建筑面积为60m2的房间设置1个疏散门",{"key":27,"text":139,"correct":32},"夜总会所在空间划分3个防烟分区，设置一套机械排烟风机",{"key":30,"text":141,"correct":22},"每个房间采用耐火极限1.00h的防火隔墙与其它房间分隔",{"key":143,"text":144,"correct":32},"E","夜总会所在空间采用耐火极限为2.00h的防火隔墙与设备区分隔","ACE",{"id":147,"libraryId":5,"type":130,"typeLabel":131,"stem":148,"options":149,"answer":160,"analysis":33},932100,"（2017真题）下列设置在商业综合体建筑地下一层的场所中，疏散门应直通室外或安全出口的有（ ）",[150,152,154,156,158],{"key":20,"text":151,"correct":22},"锅炉房",{"key":24,"text":153,"correct":22},"柴油发电机房",{"key":27,"text":155,"correct":22},"油浸变压器室",{"key":30,"text":157,"correct":32},"消防水泵房",{"key":143,"text":159,"correct":32},"消防控制室","DE",{"id":162,"libraryId":5,"type":130,"typeLabel":131,"stem":163,"options":164,"answer":175,"analysis":33},932101,"（2018真题）下列住宅建筑安全出口，疏散楼梯和户门的设计方案，正确的有（ ）。",[165,167,169,171,173],{"key":20,"text":166,"correct":22},"建筑高度 27m 住宅，各单元每层建筑面积 700 ㎡，每层设 1 个安全出口",{"key":24,"text":168,"correct":32},"建筑高度 18m 住宅，敞开楼梯间与电梯井相邻，户门采用乙级防火门",{"key":27,"text":170,"correct":22},"建筑高度 36m 住宅，采用封闭楼梯间",{"key":30,"text":172,"correct":22},"建筑高度 56m 住宅，每个单元设置 1 个安全出口，户门采用乙级防火门",{"key":143,"text":174,"correct":32},"建筑高度 30m 住宅，采用敞开楼梯间，户门采用乙级门","BE",{"id":177,"libraryId":5,"type":130,"typeLabel":131,"stem":178,"options":179,"answer":190,"analysis":33},932102,"（2018真题）某公共建筑，共 4 层，建筑高度 22m，其中一至三层为商店，四层为电影院；电影院的独立疏散楼梯采用室外疏散楼梯。该室外疏散楼梯的下列设计方案中，正确的有( )。",[180,182,184,186,188],{"key":20,"text":181,"correct":22},"室外楼梯平台的耐火极限为 0.50h",{"key":24,"text":183,"correct":32},"室外楼梯栏杆扶手的高度为 1.10m",{"key":27,"text":185,"correct":32},"室外楼梯倾斜角度为 45°",{"key":30,"text":187,"correct":22},"室外楼梯周围 2m 内的墙面上不设置门、窗、洞口",{"key":143,"text":189,"correct":22},"建筑二、三、四层通向该室外楼梯的门采用乙级防火门","BC",{"id":192,"libraryId":5,"type":130,"typeLabel":131,"stem":193,"options":194,"answer":205,"analysis":33},932103,"（2018真题）下列厂房中，可设1个安全出口的有（）。",[195,197,199,201,203],{"key":20,"text":196,"correct":32},"每层建筑面积80m2，同一时间的作业人数为4人的赤磷制备厂房",{"key":24,"text":198,"correct":32},"每房建筑面积160m2，时间的作业人数为8人的木工厂房",{"key":27,"text":200,"correct":22},"每层建筑面积240m2，同一时间的作业人数为12人的空分厂房",{"key":30,"text":202,"correct":22},"每层建筑面积400m2，同一时间的作业人数为32人的制砖年间",{"key":143,"text":204,"correct":32},"每层建筑面积320m2，同一时间的作业人数为16人的热处理厂房","ABE",{"id":207,"libraryId":5,"type":130,"typeLabel":131,"stem":208,"options":209,"answer":220,"analysis":33},932104,"（2019年真题）某体育馆，耐火等级二级，可容纳8600人，若疏散门净宽为2.2m，则下列设计参数中，适用于该体育馆疏散门设计的有（）",[210,212,214,216,218],{"key":20,"text":211,"correct":32},"允许疏散时间不大于3.0min",{"key":24,"text":213,"correct":32},"允许疏散时间不大于3.5min",{"key":27,"text":215,"correct":32},"疏散门的设置数量为17个",{"key":30,"text":217,"correct":32},"每100人所需最小疏散净宽度为0.43m",{"key":143,"text":219,"correct":22},"通向疏散门的纵向走道的通行人流股数为5股","ABCD",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":20,"analysis":33},932105,"（2019年真题）某建筑高度为50m的大型公共建筑，若避难走道一 端设置安全出口且仅在避难走道前室设置机械加压送风系统，则避难走道的总长度应小于（） 。",[225,227,228,229],{"key":20,"text":226,"correct":32},"30m",{"key":24,"text":57,"correct":22},{"key":27,"text":51,"correct":22},{"key":30,"text":55,"correct":22},{"id":231,"libraryId":5,"type":130,"typeLabel":131,"stem":232,"options":233,"answer":205,"analysis":33},932106,"（2019年真题）某一级耐火等级的服装厂，共7层，建筑高度32m，每层划分为一个防火分区。各层使用人数为：第二层300人，第三层260人，第四层280人，第五层至第七层每层290人。关于该厂房疏散楼梯的说法，正确的有（）",[234,236,238,240,242],{"key":20,"text":235,"correct":32},"四层至三层的疏散楼梯总净宽度不应小于2.90m",{"key":24,"text":237,"correct":32},"二层至一层的疏散楼梯总净宽度不应小于3.00m",{"key":27,"text":239,"correct":22},"五层至四层的疏散楼梯总净宽度不应小于3.00m",{"key":30,"text":241,"correct":22},"三层至二层的疏散楼梯总净宽度不应小于2.40m",{"key":143,"text":243,"correct":32},"疏散楼梯应采用封闭楼梯间或室外楼梯",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":27,"analysis":33},932107,"（2020年真题）某建筑总高度为35m，首层及二层为商场营业厅，营业厅每层层高为4.5m，三层及以上为住宅,住宅各单元每层的建筑面积均为600m2，关于该建筑住宅部分疏散设施设置的说法，错误的是（ ）。",[248,250,252,254],{"key":20,"text":249,"correct":22},"疏散楼梯间应采用防烟楼梯间",{"key":24,"text":251,"correct":22},"户门的净宽度不应小于0.9m",{"key":27,"text":253,"correct":32},"任一户门至最近安全出口的距离不大于15m时，每个单元每层的安全出口可为1个",{"key":30,"text":255,"correct":22},"任一户门至最近疏散楼梯间入口的距离不大10m时，住宅单元可采用剪刀楼梯间",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":27,"analysis":33},932108,"（2020年真题）某商场三层划分为2个防火分区，防火分区1的建筑面积为3600m2，防火分区2的建筑面积为900m2，防火分区2利用通向防火分区1的甲级防火门作为安全出口，关于该商场防火分隔和疏散设施的的设置，错误的是（ ）。",[260,262,264,266],{"key":20,"text":261,"correct":22},"防火分区2设有1个直通室外的安全出口",{"key":24,"text":263,"correct":22},"防火分区1和防火分区2之间的防火墙的长度为27m，墙上设9m宽的防火卷帘",{"key":27,"text":265,"correct":32},"防火分区2通向防火分区1的甲级防火门净宽度为1.4m",{"key":30,"text":267,"correct":22},"三层安全出口总净宽度为防火分区1和防火2各自计算所需疏散净宽度之和",{"id":269,"libraryId":5,"type":130,"typeLabel":131,"stem":270,"options":271,"answer":282,"analysis":33},932109,"（2020年真题）某耐火等级为二级的商场，地上3层，建筑高度为13m，总建筑面积为22000m2，商场无敞开式外廊，商场营业厅内任一点均可直通疏散楼梯间。关于该商场疏散楼梯间的说法，错误的有（ ）。",[272,274,276,278,280],{"key":20,"text":273,"correct":22},"商场应采用封闭楼梯间",{"key":24,"text":275,"correct":22},"疏散楼梯间的门应采用乙级防火门",{"key":27,"text":277,"correct":32},"三层营业厅内任一点至最近疏散楼梯间的直线距离不应大于30m",{"key":30,"text":279,"correct":22},"商场可将直通室外的门设置在距疏散楼梯间不大于15m处",{"key":143,"text":281,"correct":32},"开向疏散楼梯间的储藏室门应采用乙级防火门","CE",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":30,"analysis":33},932110,"（2020年真题）下列建筑中,应设置消防电梯的是（ ）。",[287,289,291,293],{"key":20,"text":288,"correct":22},"建筑高度为30m,每层层高为3m、建筑面积为1500m2的住宅建筑",{"key":24,"text":290,"correct":22},"建筑高度为30m,每层层高为5m、建筑面积为3000m2的企业办公楼",{"key":27,"text":292,"correct":22},"埋深为9m,每层层高为4.5m,总建筑面积为6000m2的独立建造的地下服装仓库",{"key":30,"text":294,"correct":32},"建筑高度为30m,每层层高为5m、建筑面积为2000m2的石材批发商场",{"id":296,"libraryId":5,"type":130,"typeLabel":131,"stem":297,"options":298,"answer":309,"analysis":33},932111,"（2020年真题）某地下1层商场划分为3个防火分区，并设有1条避难走道，各防火分区通向避难走道的设计疏散总净宽度分别为2m、3m、2m。关于该避难走道的说法，错误的有（ ）。",[299,301,303,305,307],{"key":20,"text":300,"correct":32},"避难走道直通地面的出口不应少于3个",{"key":24,"text":302,"correct":32},"通向避难走道的门至该避难走道任一通向地面出口的距离不应大于60m",{"key":27,"text":304,"correct":32},"避难走道的净宽度不应小于5m",{"key":30,"text":306,"correct":22},"避难走道防火隔墙的耐火极限不应低于3.00h",{"key":143,"text":308,"correct":22},"各防火分区至避难走道入口处应设置防烟前室","ABC",{"id":311,"libraryId":5,"type":130,"typeLabel":131,"stem":312,"options":313,"answer":324,"analysis":33},932112,"（2020年真题）某宾馆在疏散走道外窗处设有缓降器。关于该缓降器的说法，错误的有（ ）。",[314,316,318,320,322],{"key":20,"text":315,"correct":32},"缓降器的下降速度应为1m\u002Fs~2m\u002Fs",{"key":24,"text":317,"correct":22},"缓降器由摩擦棒、套筒、自救绳和绳盒等组成",{"key":27,"text":319,"correct":22},"使用缓降器时应将自救绳和安全钩牢固地系在固定物上",{"key":30,"text":321,"correct":32},"缓降器不应由地面人员控制",{"key":143,"text":323,"correct":22},"消防救援人员可利用缓降器带着一人滑至地面","AD",{"id":326,"libraryId":5,"type":130,"typeLabel":131,"stem":327,"options":328,"answer":339,"analysis":33},932113,"（2020年真题）某建筑高度为135m的办公楼,设置有避难层。关于该避层的说法，错误的有（ ）。",[329,331,333,335,337],{"key":20,"text":330,"correct":22},"第一个避难层的楼地面至灭火救援场地地面的高度不应大于50m",{"key":24,"text":332,"correct":32},"建筑至少应设置3个避难层",{"key":27,"text":334,"correct":22},"避难层应急疏散照明的地面最低水平照度不应低于3.0lx",{"key":30,"text":336,"correct":32},"避难层的设备间应采用耐火极限不低于1.50h的防火隔墙与避难区分隔",{"key":143,"text":338,"correct":32},"管道井直接开向避难区的门，与避难区出入口的距离不应小于4m","BDE",{"id":341,"libraryId":5,"type":130,"typeLabel":131,"stem":342,"options":343,"answer":354,"analysis":33},932114,"（2020年真题）某耐火等级为二级的办公楼，地上5层，建筑高度为18m,各层使用人数为:二层350人,三层400人，四层300人，五层280人。关于该办公楼疏散楼梯的说法，错误的有（ ）。",[344,346,348,350,352],{"key":20,"text":345,"correct":22},"五层至四层的疏散楼梯总净宽度不应小于2.8m",{"key":24,"text":347,"correct":32},"疏散楼梯应采用封闭楼梯间",{"key":27,"text":349,"correct":32},"三层至二层的疏散楼梯总净宽度不应小于3.0m",{"key":30,"text":351,"correct":22},"四层至三层的疏散楼梯总净宽度不应小于3.0m",{"key":143,"text":353,"correct":32},"二层至一层的疏散楼梯总净宽度不应小于3.0m","BCE",{"id":356,"libraryId":5,"type":130,"typeLabel":131,"stem":357,"options":358,"answer":369,"analysis":33},932115,"（2017真题）下列照明灯具的防火措施中，符合规范要求的有（ ）。",[359,361,363,365,367],{"key":20,"text":360,"correct":32},"燃气锅炉房内固定安装任意一种防爆类型的照明灯具",{"key":24,"text":362,"correct":22},"照明线路接头采用钎焊焊接并用绝缘布包好，配电盘后线路接头数量不限",{"key":27,"text":364,"correct":32},"潮湿的厂房内外采用封闭型灯具或有防水型灯座的开启型灯具",{"key":30,"text":366,"correct":22},"木制吊顶上安装附带镇流器的荧光灯具",{"key":143,"text":368,"correct":22},"舞池脚灯的电源导线采用截面积不小于2.5mm2阻燃电缆明敷","AC",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":30,"analysis":33},932116,"（2015真题）在火焰中被燃烧，一定时间内仍能正常运行的电缆是（ ）。",[374,376,378,380],{"key":20,"text":375,"correct":22},"一般阻燃电缆",{"key":24,"text":377,"correct":22},"低烟无卤阻燃电缆",{"key":27,"text":379,"correct":22},"无卤阻燃电缆",{"key":30,"text":381,"correct":32},"耐火电缆",{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":20,"analysis":33},932117,"（2015真题）下列内容中，不属于电气防爆检查的是（ ）。",[386,388,390,392],{"key":20,"text":387,"correct":32},"可燃粉尘干式除尘器是否布置在系统的负压段上",{"key":24,"text":389,"correct":22},"导线材质",{"key":27,"text":391,"correct":22},"电气线路敷设方式",{"key":30,"text":393,"correct":22},"带电部件的接地",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":24,"analysis":33},932118,"（2015真题）某棉纺织厂的纺织联合厂房，在通风机的前端设置滤尘器对空气进行净化处理。如需将过滤后的空气循环使用，应使空气中的含尘浓度低于其爆炸下限的（ ）。",[398,400,402,404],{"key":20,"text":399,"correct":22},"15%",{"key":24,"text":401,"correct":32},"25%",{"key":27,"text":403,"correct":22},"50%",{"key":30,"text":405,"correct":22},"100%",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":27,"analysis":33},932119,"（2017真题）某氯酸钾厂房通风、空调系统的下列做法中，不符合现行国家消防技术标准的是（ ）。",[410,412,414,416],{"key":20,"text":411,"correct":22},"通风设施设置导除静电的接地装置",{"key":24,"text":413,"correct":22},"排风系统采用防爆型通风设备",{"key":27,"text":415,"correct":32},"厂房内的空气在循环使用前经过净化处理，并使空气中的含尘浓度低于其爆炸下限的25%",{"key":30,"text":417,"correct":22},"厂房内选用不发生火花的除尘器",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":30,"analysis":33},932120,"（2017真题）根据现行国家消防技术标准，下列净化或输送有爆炸危险粉尘和碎屑的设施上，不需要设置泄压装置的是（ ）。",[422,424,426,428],{"key":20,"text":423,"correct":22},"除尘器",{"key":24,"text":425,"correct":22},"过滤器",{"key":27,"text":427,"correct":22},"管道",{"key":30,"text":429,"correct":32},"风机",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":27,"analysis":33},932121,"（2016真题）下列关于电气装置设置的做法中，错误的是（）。",[434,436,438,440],{"key":20,"text":435,"correct":22},"在照明灯具靠近可燃物处采取隔热防火措施",{"key":24,"text":437,"correct":22},"额定功率为150W的吸顶白炽灯的引入线采用陶瓷管保护",{"key":27,"text":439,"correct":32},"额定功率为60W的白炽灯直接安装在木梁上",{"key":30,"text":441,"correct":22},"可燃材料仓库内使用密闭型荧光灯具",{"id":443,"libraryId":5,"type":130,"typeLabel":131,"stem":444,"options":445,"answer":145,"analysis":33},932122,"（2018真题）聚氯乙烯电缆燃烷时,燃烧产物有( )",[446,448,450,452,454],{"key":20,"text":447,"correct":32},"炭瘤",{"key":24,"text":449,"correct":22},"氮氧化物",{"key":27,"text":451,"correct":32},"腐蚀性气体",{"key":30,"text":453,"correct":22},"熔滴",{"key":143,"text":455,"correct":32},"水蒸气",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":20,"analysis":33},932123,"（2015真题）燃煤发电厂的碎煤机房设置照明灯具时，应迭择( )灯具。",[460,462,464,466],{"key":20,"text":461,"correct":32},"密闭型",{"key":24,"text":463,"correct":22},"隔爆型",{"key":27,"text":465,"correct":22},"增安型",{"key":30,"text":467,"correct":22},"充砂型",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":24,"analysis":33},932124,"（2017真题）某地上4层乙类厂房，其有爆炸危险的生产部位宜设置在第（ ）层靠外墙泄压设施附近。",[472,474,476,478],{"key":20,"text":473,"correct":22},"三",{"key":24,"text":475,"correct":32},"四",{"key":27,"text":477,"correct":22},"二",{"key":30,"text":479,"correct":22},"一",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":30,"analysis":33},932125,"（2017真题）下列建筑防爆措施中，不属于预防性措施的是（ ）。",[484,486,488,490],{"key":20,"text":485,"correct":22},"生产过程中尽量不用具有爆炸性危险的可燃物质",{"key":24,"text":487,"correct":22},"消除静电火花",{"key":27,"text":489,"correct":22},"设置可燃气体浓度报警装置",{"key":30,"text":491,"correct":32},"设置泄压构件",{"id":493,"libraryId":5,"type":130,"typeLabel":131,"stem":494,"options":495,"answer":160,"analysis":33},932126,"（2017真题）对某动物饲料加工厂的谷物碾磨车间进行防火检查，查阅资料得知，该车间耐火等级为一级，防火分区划分符合规范要求。该车间的下列做法中，符合现行国家消防技术标准要求的有 （ ）。",[496,498,500,502,504],{"key":20,"text":497,"correct":22},"配电站设于厂房内的一层，采用防火墙和耐火极限 1.50h 的楼板与其他区域分隔，墙上的门为甲级防火门",{"key":24,"text":499,"correct":22},"位于厂房三层的运行调度监控室采用防火墙和耐火极限 1. 50h 的楼板与其他部分分隔，且设有独立使用的防烟楼梯间",{"key":27,"text":501,"correct":22},"车间办公室贴邻厂房外墙设置，采用耐火极限 4.00h 的防火墙与厂房分隔，并设有独立的 安全出口",{"key":30,"text":503,"correct":32},"设置在一层的产品临时存放仓库单独划分防火分区",{"key":143,"text":505,"correct":32},"位于二层的饲料添加剂仓库（丙类）采用防火墙和耐火极限为 1.5h的楼板与其他部分分 隔，墙上的门为甲级防火门",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":20,"analysis":33},932127,"（2016真题）有爆炸危险区域内的楼梯间、室外楼梯或有爆炸危险的区域与相邻区域连通处，应设置门斗等防护措施，下列门斗的做法中，符合现行国家消防技术标准规定的是（ ）。",[510,512,514,516],{"key":20,"text":511,"correct":32},"门斗隔墙的耐火极限为2.0h，门采用甲级防火门并与楼梯间门错位",{"key":24,"text":513,"correct":22},"门斗隔墙的耐火极限为1.5h，门采用甲级防火门并与楼梯间门正对",{"key":27,"text":515,"correct":22},"门斗隔墙的耐火极限为2.0h，门采用乙级防火门并与楼梯间门正对",{"key":30,"text":517,"correct":22},"门斗隔墙的耐火极限为2.5h，门采用乙级防火门并与楼梯间门错位",{"id":519,"libraryId":5,"type":130,"typeLabel":131,"stem":520,"options":521,"answer":220,"analysis":33},932128,"（2017真题）某设计院对有爆炸危险的甲类厂房进行设计，下列防爆设计方案中，符合现行国家标准《建筑设计防火规范》GB50016 的有（ ）。",[522,524,526,528,530],{"key":20,"text":523,"correct":32},"厂房承重结构采用钢筋混凝土结构",{"key":24,"text":525,"correct":32},"厂房的总控制室独立设置",{"key":27,"text":527,"correct":32},"厂房的地面采用不发火花地面",{"key":30,"text":529,"correct":32},"厂房的分控制室贴邻厂房外墙设置，并采用耐火极限不低于3.00h 的防火隔墙与其他部位分离",{"key":143,"text":531,"correct":22},"厂房利用门窗座位泄压设施，窗玻璃采用普通玻璃",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":24,"analysis":33},932129,"（2016真题）燃煤发电厂的碎煤机房设置照明灯具时，应选择（ ）灯具。",[536,538,539,540],{"key":20,"text":537,"correct":22},"外壳保护型",{"key":24,"text":463,"correct":32},{"key":27,"text":465,"correct":22},{"key":30,"text":467,"correct":22},{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":24,"analysis":33},932130,"（2017真题）下列甲醇生产车间内电缆、导线的选型及敷设的做法中，不符合现行国家消防技术标准要求的是（ ）。",[545,547,549,551],{"key":20,"text":546,"correct":22},"低压电力线路绝缘导线的额定电压等于工作电压",{"key":24,"text":548,"correct":32},"在1 区内的供电线路采用铝芯电缆",{"key":27,"text":550,"correct":22},"接线箱内的供配电线路采用无护套的电线",{"key":30,"text":552,"correct":22},"电气线路在较高处敷设",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":30,"analysis":33},932131,"（2017真题）某金属原件抛光车间的下列做法中，不符合规范要求的是（ ）。",[557,559,561,563],{"key":20,"text":558,"correct":22},"采用铜芯绝缘导线做配线",{"key":24,"text":560,"correct":22},"导线的链接采用压接方式",{"key":27,"text":562,"correct":22},"带电部件的接地干线有两处与接地体相连",{"key":30,"text":564,"correct":32},"电气设备按潮湿环境选用",{"id":566,"libraryId":5,"type":130,"typeLabel":131,"stem":567,"options":568,"answer":220,"analysis":33},932132,"（2015真题）某食用油加工厂，拟新建一单层大豆油浸出车间厂房，其耐火等级为一级，车间需设置与生产配套的浸出溶剂中间仓库、分控制室、办公室和专用10KV变电所。对该厂房进行总平面布局和平面布置时，正确的措施有（）。",[569,571,573,575,577],{"key":20,"text":570,"correct":32},"车间专用10KV变电所贴邻厂房建造，并用无门窗洞口的防火墙与厂房分隔",{"key":24,"text":572,"correct":32},"中间仓库在厂房内靠外墙布置，并用防火墙与其他部位分隔",{"key":27,"text":574,"correct":32},"分控制室贴邻厂房外墙设置，并采用耐火极限为4.00h的防火墙与厂房分隔",{"key":30,"text":576,"correct":32},"厂房平面采用矩形布置",{"key":143,"text":578,"correct":22},"办公室设置在厂房内，并与其他区域之间设耐火极限为2.00h的隔墙分隔",{"id":580,"libraryId":5,"type":15,"typeLabel":16,"stem":581,"options":582,"answer":27,"analysis":33},932133,"（2016真题）下列关于建筑防爆的基本措施中，不属于减轻性技术措施的是（ ）",[583,585,587,589],{"key":20,"text":584,"correct":22},"设置防爆墙",{"key":24,"text":586,"correct":22},"设置泄压面积",{"key":27,"text":588,"correct":32},"采用不发火花的地面",{"key":30,"text":590,"correct":22},"采用合理的平面布置",{"id":592,"libraryId":5,"type":15,"typeLabel":16,"stem":593,"options":594,"answer":30,"analysis":33},932134,"（2015真题）某金属部件加工厂的滤芯抛光车间厂房内设有一地沟，该厂所采取的下列防爆措施中，不符合要求的是( )。",[595,597,598,600],{"key":20,"text":596,"correct":22},"用盖板将车间内的地沟严密封闭",{"key":24,"text":588,"correct":22},{"key":27,"text":599,"correct":22},"设置除尘设施",{"key":30,"text":601,"correct":32},"采用粗糙的防滑地板",{"id":603,"libraryId":5,"type":15,"typeLabel":16,"stem":604,"options":605,"answer":24,"analysis":33},932135,"（2015真题）下列建筑电气防爆基本措施中，错误的是( )。",[606,608,610,612],{"key":20,"text":607,"correct":22},"选用与爆炸危险区域和范围相适应的防爆电气设备",{"key":24,"text":609,"correct":32},"在同时存在爆炸性气体和粉尘的区域，按照爆炸性气体的防爆要求电气设备",{"key":27,"text":611,"correct":22},"设置防爆型剩余电流式电气火灾监控报警系统和紧急断电装置",{"key":30,"text":613,"correct":22},"将在正常运行时会产生火花，电孤的电气设备和线路布置在爆炸危险性小或没有爆炸危险性的环境内",{"id":615,"libraryId":5,"type":130,"typeLabel":131,"stem":616,"options":617,"answer":628,"analysis":33},932136,"（2018真题）某植物油加工厂的浸出车间，地上3层，建筑物高度为15m，漫出车间设计方案中，正确的有()",[618,620,622,624,626],{"key":20,"text":619,"correct":32},"车间地面采用不发火花的地面",{"key":24,"text":621,"correct":22},"漫出车间与工厂总控制室贴邻设置",{"key":27,"text":623,"correct":22},"车间管、沟釆取保护措施后与相邻厂房的管、沟相通",{"key":30,"text":625,"correct":32},"浸出工段内的封闭楼梯间设置门斗",{"key":143,"text":627,"correct":32},"泄压设施采用安全玻璃","ADE",{"id":630,"libraryId":5,"type":15,"typeLabel":16,"stem":631,"options":632,"answer":27,"analysis":33},932137,"（2020年真题）下列防爆措施中，属于减轻性技术措施的是（ ）。",[633,635,637,639],{"key":20,"text":634,"correct":22},"防止撞击产生火花",{"key":24,"text":636,"correct":22},"加强通风除尘",{"key":27,"text":638,"correct":32},"采用抗爆性能良好的结构",{"key":30,"text":640,"correct":22},"利用惰性介质进行保护",{"id":642,"libraryId":5,"type":130,"typeLabel":131,"stem":643,"options":644,"answer":369,"analysis":33},932138,"（2017真题）关于锅炉房防火防爆设计的做法,正确的有（ ）。",[645,647,649,651,653],{"key":20,"text":646,"correct":32},"燃气锅炉房选用防爆型事故排风机",{"key":24,"text":648,"correct":22},"锅炉房设置在地下一层靠外墙部位，上一层为西餐厅,下一层为汽车库",{"key":27,"text":650,"correct":32},"设点型感温火灾探测器",{"key":30,"text":652,"correct":22},"总储存量为3m3的储油间与锅炉房之间用3h的防火墙和甲级防火门分隔",{"key":143,"text":654,"correct":22},"电力线路采用绝缘线明敷",{"id":656,"libraryId":5,"type":15,"typeLabel":16,"stem":657,"options":658,"answer":20,"analysis":33},932139,"（2017真题）下列设置在公共建筑内的柴油发电机房的设计方案中，错误的是（ ）。",[659,661,663,665],{"key":20,"text":660,"correct":32},"采用轻柴油作为柴油发电机燃料",{"key":24,"text":662,"correct":22},"燃料管道在进入建筑物前设置自动和手动切断阀",{"key":27,"text":664,"correct":22},"储油间的通气管上设置带阻火器的呼吸阀，油箱的下部应设置防止油品流散的设施。",{"key":30,"text":666,"correct":22},"可设置湿式自动喷水灭火系统",[668,671,674,677,680,683],{"id":15,"name":669,"category":7,"favorite":670},"领导干部任职前廉政法规知识测试题",92,{"id":672,"name":673,"category":7,"favorite":15},595,"建筑结构与设备",{"id":675,"name":676,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":678,"name":679,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":681,"name":682,"category":7,"favorite":8},534,"BIM工程师",{"id":684,"name":682,"category":7,"favorite":8},535]