[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-8":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":653},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,8,50,2960,[13,34,52,64,76,88,100,115,127,139,154,169,183,195,207,219,231,243,255,267,279,291,303,315,330,342,357,369,381,393,405,420,435,447,459,474,486,498,510,522,534,546,560,572,586,598,610,618,629,641],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},932040,1,"单选题","（2018真题）某建筑高度为110m的35层住宅建筑,首层设有商业服务网点,该住宅建筑构件耐火极限设计方中，错误的是（）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","居住部分与商业服务网点之间墙的耐火极限为2.00h",false,{"key":24,"text":25,"correct":26},"B","居住部分与商业服务网点之间楼板的耐火极限为1.50h",true,{"key":28,"text":29,"correct":22},"C","居住部分疏散走道两侧墙的耐火极限为1.00h",{"key":31,"text":32,"correct":22},"D","居住部分分户墙的而火极限为2.00h","",{"id":35,"libraryId":5,"type":36,"typeLabel":37,"stem":38,"options":39,"answer":51,"analysis":33},932041,2,"多选题","（2018真题）根据现行国家标准《建筑设计防火规范》，下列民用建筑防火间距设计方案中，正确的有（ ）。",[40,42,44,46,48],{"key":20,"text":41,"correct":26},"建筑高度为 32m 住宅建筑与建筑高度 25m 办公楼，相邻侧外墙均设有普通门窗，建筑之间的间距为 13m",{"key":24,"text":43,"correct":26},"建筑高度为 22m 的商场建筑与 10KV 的预装式变电站，相邻侧商场建筑外墙设有普通门窗， 建筑之间的间距为 3m",{"key":28,"text":45,"correct":22},"建筑高度为 22m 的商场建筑与建筑高度为 120m 酒店，相邻外墙为防火墙，建筑之间间距不限",{"key":31,"text":47,"correct":22},"建筑高度为 32m 住宅建筑与木结构体育馆，相邻侧外墙均设有普通门窗，建筑之间间距不限",{"key":49,"text":50,"correct":22},"E","建筑高度为 32m 住宅建筑与建筑高度 22m 的二级耐火等级商场建筑，相邻侧外墙均设有普通门窗，建筑之间间距为 6m","AB",{"id":53,"libraryId":5,"type":15,"typeLabel":16,"stem":54,"options":55,"answer":31,"analysis":33},932042,"（2018真题）根据现行国家标准《建筑设计防火规范》（GB50016），不宜布置在民用建筑附近的厂房是（）。",[56,58,60,62],{"key":20,"text":57,"correct":22},"橡胶制品硫化厂房",{"key":24,"text":59,"correct":22},"苯甲酸生产厂房",{"key":28,"text":61,"correct":22},"甘油制备厂房",{"key":31,"text":63,"correct":26},"活性炭制造厂房",{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":24,"analysis":33},932043,"（2016真题）关于建筑防火分隔的做法中，错误的是( )。",[68,70,72,74],{"key":20,"text":69,"correct":22},"卡拉OK厅各厅室之间采用耐火极限为2.00h的防火墙面和1.5h的不燃性楼板和乙级防火门分隔",{"key":24,"text":71,"correct":26},"柴油发电机房内的储油问(柴油储量为0.8m3)，采用耐火极限为2.50h的防火隔墙和1.50h的不燃性楼板和甲级防火门与其他部位分隔",{"key":28,"text":73,"correct":22},"高层住宅建筑下部设置的商业服务网点，采用耐火极限为2.50h且无门、窗、洞口的防火隔墙和1.50h的不燃性楼板与其他部位分隔",{"key":31,"text":75,"correct":22},"医院病房内相邻护理单元之间采用耐火极限为2.00h的防火隔墙和乙级防火门分隔",{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":28,"analysis":33},932044,"（2016真题）下列关于建筑的总平面布局中，错误的是（ ）。",[80,82,84,86],{"key":20,"text":81,"correct":22},"桶装乙醇仓库与相邻高层仓库的防火间距为15m",{"key":24,"text":83,"correct":22},"电解食盐水厂房与相邻多层厂区办公楼的防火间距为27m",{"key":28,"text":85,"correct":26},"发生炉煤气净化车间的总控制室与车间贴邻，并采用钢筋混凝土防爆墙分隔",{"key":31,"text":87,"correct":22},"空分厂房专用10KV变配电站采用设置甲级防火窗的防火墙与空分厂房一面贴邻",{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":20,"analysis":33},932045,"（2017真题）下列设置在公共建筑内的柴油发电机房的设计方案中，错误的是（ ）",[92,94,96,98],{"key":20,"text":93,"correct":26},"采用轻柴油作为柴油发电机燃料",{"key":24,"text":95,"correct":22},"燃料管道在进入建筑物前设置自动和手动切断阀",{"key":28,"text":97,"correct":22},"火灾自动报警系统采用感温探测器",{"key":31,"text":99,"correct":22},"设置湿式自动喷水灭火系统",{"id":101,"libraryId":5,"type":36,"typeLabel":37,"stem":102,"options":103,"answer":114,"analysis":33},932046,"（2018真题）下列办公建筑内会议厅的平面布置方案中，正确的有（ ）。",[104,106,108,110,112],{"key":20,"text":105,"correct":22},"耐火等级为二级的办公建筑，将建筑面积为 300 ㎡的会议厅布置在地下一层",{"key":24,"text":107,"correct":22},"耐火等级为一级的办公建筑，将建筑面积为 600 ㎡的会议厅布置在地上四层",{"key":28,"text":109,"correct":26},"耐火等级为一级的办公建筑，将建筑面积为 200 ㎡的会议厅布置在地下二层",{"key":31,"text":111,"correct":26},"耐火等级为二级的办公建筑，将建筑面积为 500 ㎡的会议厅布置在地上三层",{"key":49,"text":113,"correct":22},"耐火等级为三级的办公建筑，将建筑面积为 200 ㎡的会议厅布置在地上三层","CD",{"id":116,"libraryId":5,"type":15,"typeLabel":16,"stem":117,"options":118,"answer":28,"analysis":33},932047,"（2019年真题）某加油站，拟设埋地汽油罐及柴油罐各3个，每个汽油罐容积为30㎡。该加油站的下列设计中，正确的是（）。",[119,121,123,125],{"key":20,"text":120,"correct":22},"罩棚设置在杆高8m的架空电线下方，埋地油罐与该储罐的水平间距为13m",{"key":24,"text":122,"correct":22},"汽油罐与柴油罐的通气管道分开设置，通气管口高出地面3.6m",{"key":28,"text":124,"correct":26},"布置在城市中心区，靠近城市道路，并远离城市干道交叉路口",{"key":31,"text":126,"correct":22},"站内道路转弯半径9m，站内停车场及道路路面采用沥青路面",{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":24,"analysis":33},932048,"（2019年真题）用于收集火灾工况下受污染的消防水、污染的雨水及可能泄露的可燃液体的事故水池，宜布置在厂区边缘较低处。事故水池距明火地点的防火间距不应小于（）",[131,133,135,137],{"key":20,"text":132,"correct":22},"100m",{"key":24,"text":134,"correct":26},"25m",{"key":28,"text":136,"correct":22},"60m",{"key":31,"text":138,"correct":22},"50m",{"id":140,"libraryId":5,"type":36,"typeLabel":37,"stem":141,"options":142,"answer":153,"analysis":33},932049,"（2019年真题）某综合楼高度为110m,设置自动喷水灭火系统。该综合楼内柴油发电机房的下列设计方案中,正确的有( )。",[143,145,147,149,151],{"key":20,"text":144,"correct":26},"机房内设置自动喷水灭火系统",{"key":24,"text":146,"correct":22},"机房与周围场所采用耐火极限2. 0h的防火隔墙和1. 0h的不燃性楼板分隔",{"key":28,"text":148,"correct":22},"为柴油发电机共有的12m3储罐直埋于室外距综合楼外墙3m处，毗邻油罐的外墙4m范围为防火墙",{"key":31,"text":150,"correct":22},"储油间采用耐火极限为2. 5h的防火隔墙与发电机间分隔，隔墙上设置甲级防火门",{"key":49,"text":152,"correct":26},"柴油发电机房布置在地下二层","AE",{"id":155,"libraryId":5,"type":36,"typeLabel":37,"stem":156,"options":157,"answer":168,"analysis":33},932050,"（2020年真题）下列建筑的耐火等级均为二级，建筑间的防火间距符合现行国家标准《建筑设计防火规范》（GB 50016）要求的有（ ）。",[158,160,162,164,166],{"key":20,"text":159,"correct":26},"单层氟利昂厂房与建筑高度为33m的住宅建筑的距离为12m",{"key":24,"text":161,"correct":22},"变压器总油量为20t的室外变电站与建筑高度为33m的住宅建筑的距离为14m",{"key":28,"text":163,"correct":26},"单层煤粉厂房与建筑高度为20m的住宅建筑的距离为25m",{"key":31,"text":165,"correct":26},"单层造纸厂房与建筑高度为20m的住宅建距离为10m",{"key":49,"text":167,"correct":26},"供热锅炉房与建筑高度为33m的住宅建筑的距离为14m","ACDE",{"id":170,"libraryId":5,"type":36,"typeLabel":37,"stem":171,"options":172,"answer":114,"analysis":33},932051,"（2017真题）某商业建筑，建筑高度23.3m，地上标准层每层划分为面积相近的2个防火分区，防火分隔部位的宽度为60m，该商业建筑的下列防火分隔做法中，正确的有（）。",[173,175,177,179,181],{"key":20,"text":174,"correct":22},"防火墙设置两个不可开启的乙级防火窗",{"key":24,"text":176,"correct":22},"防火墙上设置两樘常闭式乙级防火门",{"key":28,"text":178,"correct":26},"设置总宽度为18m，耐火极限为3.00h的特级防火卷帘",{"key":31,"text":180,"correct":26},"采用耐火极限为3.00h的不燃性墙体从楼地面基层隔断至梁或楼板底面基层",{"key":49,"text":182,"correct":22},"通风管道在穿越防火墙处设置一个排烟防火阀",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":20,"analysis":33},932052,"（2017真题）关于中庭与周围连通空间进行防火分隔的做法，错误的是（）。",[187,189,191,193],{"key":20,"text":188,"correct":26},"采用乙级防火门、窗，且火灾时能自行关闭",{"key":24,"text":190,"correct":22},"采用耐火极限为1.00h的防火隔墙",{"key":28,"text":192,"correct":22},"采用耐火隔热性和耐火完整性为1.00h的防火玻璃墙",{"key":31,"text":194,"correct":22},"采用耐火完整性为1.00h的非隔热性防火玻璃墙，并设置自动喷水灭火系统保护",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":24,"analysis":33},932053,"（2017真题）在对某化工厂的电解食盐车间进行防火检查时，查阅资料得知，该车间耐火等级为一级。该车间的下列做法中，不符合现行国家消防技术标准的是（ ）。",[199,201,203,205],{"key":20,"text":200,"correct":22},"丙类中间仓库设置在该车间的地上二层",{"key":24,"text":202,"correct":26},"该车间生产线贯通地下一层到地上三层",{"key":28,"text":204,"correct":22},"丙类中间仓库与其他部位的分隔墙为耐火极限 3.00h 的防火墙",{"key":31,"text":206,"correct":22},"丙类中间仓库无独立的安全出口",{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":20,"analysis":33},932054,"（2017真题）某商业综合体建筑，裙房与高层建筑主体采用防火墙分隔，地上4层，地下2 层。地下二层为汽车库，地下一层为超市及设备用房。地上各层功能包括商业营业厅、餐厅及电影院。下列场所对应的防火分区建筑面积中，错误的是（ ）。",[211,213,215,217],{"key":20,"text":212,"correct":26},"地下超市，2100 ㎡",{"key":24,"text":214,"correct":22},"商业营业厅，4800 ㎡",{"key":28,"text":216,"correct":22},"集中餐饮区，4200 ㎡",{"key":31,"text":218,"correct":22},"电影院区域，3100 ㎡",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":20,"analysis":33},932055,"（2016真题）某建筑采用防火墙进行防火分区分隔，下列防火墙的说法中，不符合要求的是（ ）。",[223,225,227,229],{"key":20,"text":224,"correct":26},"高层厂房屋面板的耐火极限低于1.00h 时，防火墙应高出屋面板0.3m",{"key":24,"text":226,"correct":22},"当防火墙设置在建筑内的转角时，内转角两侧墙上开设普通门窗，两侧门窗之间最近边缘水平距离不应小于4m",{"key":28,"text":228,"correct":22},"天然气管道严禁穿过防火墙",{"key":31,"text":230,"correct":22},"建筑外墙为难燃性或可燃性墙体时，防火墙应凸出墙的外表面0.4m 以上",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":31,"analysis":33},932056,"（2017真题）某三层内廊式办公楼，建筑高度12.5m，三级耐火等级，设置自动喷水灭火系统，每层建筑面积均为1400m3，有2部采用双向弹簧门的封闭式楼梯间。该办公楼每层一个防火分区的最大建筑面积为（）",[235,237,239,241],{"key":20,"text":236,"correct":22},"1200",{"key":24,"text":238,"correct":22},"2400",{"key":28,"text":240,"correct":22},"2800",{"key":31,"text":242,"correct":26},"1400",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":31,"analysis":33},932057,"（2015真题）某大垄地下商场，建筑面积为 40000 ㎡，采用兼做人员疏散的下沉广场进行防火分隔。下列关于下沉式广场的做法中，正确的是（ ）。",[247,249,251,253],{"key":20,"text":248,"correct":22},"用于疏散的净面积为125 ㎡",{"key":24,"text":250,"correct":22},"设置防风雨棚，四周开口高度为0.5m",{"key":28,"text":252,"correct":22},"不同区域通向下沉式广场等室外开敞空间的开口的的最大水平距离为10m",{"key":31,"text":254,"correct":26},"有一部满足疏散宽度要求并直通地面的疏散楼梯",{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":257,"options":258,"answer":20,"analysis":33},932058,"（2016真题）某钢筋混凝土结构的商场，建筑高度为23．8m。其中，地下一层至地上五层为商业营业厅，地下二层为汽车库和设备用房，建筑全部设置自动喷水灭火系统和火 灾自动报警系统，并采用不燃性材料进行内部装修。下列关于防火分区划分的做法中，错误的是（ ）。",[259,261,263,265],{"key":20,"text":260,"correct":26},"地上一层的防火分区中最大一个的建筑面积为9900㎡",{"key":24,"text":262,"correct":22},"地下一层的防火分区中最大一个的建筑面积为1980㎡",{"key":28,"text":264,"correct":22},"地上二层的防火分区中最大一个的建筑面积为4950㎡",{"key":31,"text":266,"correct":22},"地下二层的设备用房划分为一个防火分区，建筑面积为1090㎡",{"id":268,"libraryId":5,"type":15,"typeLabel":16,"stem":269,"options":270,"answer":24,"analysis":33},932059,"（2015真题）某购物中心，地下 2 层，建筑面积 65000 ㎡，设置南、北 2 个开敞的下沉式广场，下列做法中正确的是（ ）。",[271,273,275,277],{"key":20,"text":272,"correct":22},"分离后的购物中心不同区域通向北下沉式广场开口最近边缘的水平距离宜为 12m",{"key":24,"text":274,"correct":26},"南、北下沉式广场各设置 1 部直通室外地面并满足疏散宽度指标的疏散通道",{"key":28,"text":276,"correct":22},"南下沉式广场上方设雨棚，其开口面积为该空间地面面积的 20%",{"key":31,"text":278,"correct":22},"下沉式广场设置商业零售点，但不影响人员疏散",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":20,"analysis":33},932060,"（2015真题）某建筑采用防火墙划分防火分区，下列防火墙的设置中，错误的是（）。",[283,285,287,289],{"key":20,"text":284,"correct":26},"输送柴油（闪点高于60℃）的管道穿过该防火墙，穿墙管道四周缝隙采用防火堵料严密封堵",{"key":24,"text":286,"correct":22},"防火墙直接采用加气混凝土砌块砌筑，耐火极限为4.00h",{"key":28,"text":288,"correct":22},"防火墙直接设置在耐火极限为3.00h的框架梁上",{"key":31,"text":290,"correct":22},"防火墙上设置常开的甲级防火门，火灾时能够自行关闭",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":24,"analysis":33},932061,"（2015真题）对建筑划分防烟分区时，下列构件和设备中，不应用做防烟分区分隔构件和设施的是（）。",[295,297,299,301],{"key":20,"text":296,"correct":22},"特级防火卷帘",{"key":24,"text":298,"correct":26},"防火水幕",{"key":28,"text":300,"correct":22},"防火隔墙",{"key":31,"text":302,"correct":22},"高度不小于50cm的建筑结构梁",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":24,"analysis":33},932062,"（2018真题）某耐火等级为一级的公共建筑，地下 1 层，地上 5 层，建筑高度23m。地下一层为设备用房，地上一、二层为商店营业厅，三至五层为办公用房，该建筑设有自动喷水灭火系统和火灾自动报警系统，并采用不燃和难燃材料装修。该建筑下列防火分区划分方案中，错误的是（ ）。",[307,309,311,313],{"key":20,"text":308,"correct":22},"地下一层防火分区建筑面积最大为 1000m2",{"key":24,"text":310,"correct":26},"首层防火分区建筑面积最大为 10000m2",{"key":28,"text":312,"correct":22},"二层防火分区建筑面积最大为 5000m2",{"key":31,"text":314,"correct":22},"三层防火分区建筑面积最大为 4000m2",{"id":316,"libraryId":5,"type":36,"typeLabel":37,"stem":317,"options":318,"answer":329,"analysis":33},932063,"（2016真题）下列关于防火分隔的做法中，正确的有（ ）",[319,321,323,325,327],{"key":20,"text":320,"correct":26},"棉防织厂房在防火墙上设置一宽度为1.6m且耐火极限为2.0h的双扇防火门",{"key":24,"text":322,"correct":26},"5层宾馆共用一套通风空调系统，在竖向风管与每层水平风管交接处的水平管段上设置防火阀，平时处于常开状态",{"key":28,"text":324,"correct":22},"桶装甲醇仓库采用耐火极限为4.00h的防火墙划分防火分区，防火墙上设置1m宽的甲级防火门",{"key":31,"text":326,"correct":22},"分层商场内防火分区处的一个分隔部位的宽度为50m，该分隔部位使用防火卷帘进行分隔的最大宽度为20m",{"key":49,"text":328,"correct":26},"可停放300辆汽车的地下车库，每5个防烟分区共用一套的有排烟系统，排烟风管穿越防烟分区时设置排烟防火阀","ABE",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":20,"analysis":33},932064,"（2017真题）某商业综合体建筑，裙房与高层建筑主体采用防火墙分隔，地上4层，地下2层，地下二层为汽车库，地下一层为超市及设备用房，地上各层功能包括商业营业厅、餐厅及电影院，下列场所对应的防火分区建筑面积中，错误的是（ ）",[334,336,338,340],{"key":20,"text":335,"correct":26},"地下超市，2100m2",{"key":24,"text":337,"correct":22},"商业营业厅，4800m2",{"key":28,"text":339,"correct":22},"自助餐饮区，4200m2",{"key":31,"text":341,"correct":22},"电影院区域，3100m2",{"id":343,"libraryId":5,"type":36,"typeLabel":37,"stem":344,"options":345,"answer":356,"analysis":33},932065,"（2015真题）生产厂房在划分防火分区时，确定防火分区的建筑面积的主要因素有（）。",[346,348,350,352,354],{"key":20,"text":347,"correct":26},"生产的火灾危险性类别",{"key":24,"text":349,"correct":22},"厂房内火灾自动报警系统设置情况",{"key":28,"text":351,"correct":26},"厂房的层数和建筑高度",{"key":31,"text":353,"correct":26},"厂房的耐火等级",{"key":49,"text":355,"correct":22},"特殊生产工艺需要和灭火技术措施","ACD",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":24,"analysis":33},932066,"（2016真题）下列关于防烟分区划分的说法中，错误的是（）。",[361,363,365,367],{"key":20,"text":362,"correct":22},"防烟分区可采用防火隔墙划分",{"key":24,"text":364,"correct":26},"设置防烟系统的场所应划分防烟分区",{"key":28,"text":366,"correct":22},"一个防火分区可划分为多个防烟分区",{"key":31,"text":368,"correct":22},"防烟分区可采用在楼板下突出0.8m的结构梁划分",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":28,"analysis":33},932067,"（2019年真题）某燃煤电厂主厂房内的煤仓间带式输送机层采隔墙与其他部位隔开，防火隔墙的耐火极限不应小于（）。",[373,375,377,379],{"key":20,"text":374,"correct":22},"2.0h",{"key":24,"text":376,"correct":22},"1.5h",{"key":28,"text":378,"correct":26},"1.0h",{"key":31,"text":380,"correct":22},"0.5h",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":28,"analysis":33},932068,"（2019年真题）集中布置的电动汽车充电设施区设置在单层、多层、地下汽车库内时，根据现行国家标准《电动汽车分散充电设施工程技术标准》（GB\u002FTS1313），每个防火单元最大允许建筑面积分别不应大于（）?",[385,387,389,391],{"key":20,"text":386,"correct":22},"3000㎡、2500㎡、2000㎡",{"key":24,"text":388,"correct":22},"3000㎡、2000㎡、1000㎡",{"key":28,"text":390,"correct":26},"1500㎡、1250㎡、1000㎡",{"key":31,"text":392,"correct":22},"2500㎡、1200㎡、600㎡",{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":24,"analysis":33},932069,"（2020年真题）某单层建材商场，耐火等级为二级，建筑面积20000m2,商场营业厅采用不燃或难燃装修材料，该建材商场营业厅每个防火分区的最大允许建筑面积为（ ）m2。",[397,399,401,403],{"key":20,"text":398,"correct":22},"2500",{"key":24,"text":400,"correct":26},"10000",{"key":28,"text":402,"correct":22},"5000",{"key":31,"text":404,"correct":22},"4000",{"id":406,"libraryId":5,"type":36,"typeLabel":37,"stem":407,"options":408,"answer":419,"analysis":33},932070,"（2020年真题）某博物馆展厅相邻防火分区间的防火墙长30m,为满足展品运送的需要，防火墙上的开口部位采用防火卷帘进行分隔，该防火卷帘的功能和设置，正确的有（ ）。",[409,411,413,415,417],{"key":20,"text":410,"correct":26},"防火卷帘具有火灾时靠自重自动关闭功能",{"key":24,"text":412,"correct":26},"防火卷帘具有防烟性能",{"key":28,"text":414,"correct":26},"防火卷帘具有限位信号反馈的功能",{"key":31,"text":416,"correct":26},"防火卷帘的耐火极限为3.00h",{"key":49,"text":418,"correct":22},"防火卷帘的宽度为15m","ABCD",{"id":421,"libraryId":5,"type":36,"typeLabel":37,"stem":422,"options":423,"answer":434,"analysis":33},932071,"（2020年真题）关于防烟分区最大允许面积的说法,错误的有（ ）。",[424,426,428,430,432],{"key":20,"text":425,"correct":26},"商场内空间净高为5m时,防烟分区的面积不应大于1500㎡",{"key":24,"text":427,"correct":26},"丙类厂房内空间净高为6m时,防烟分区的面积不应大于2000㎡",{"key":28,"text":429,"correct":26},"丁类厂房内空间净高为7m时,防烟分区的面积不应大于2500㎡",{"key":31,"text":431,"correct":22},"宿舍建筑内空间净高为3m时,防烟分区的面积不应大于500㎡",{"key":49,"text":433,"correct":22},"办公建筑内空间净高为4m时,防烟分区的面积不应大于1000㎡","ABC",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":20,"analysis":33},932072,"（2015真题）建筑高度超过100m的公共建筑应设置避难层。下列关于避难层设置的说法中，错误的是（）。",[439,441,443,445],{"key":20,"text":440,"correct":26},"第一个避难层的楼地面至灭火救援场地地面的高度不应大于60m",{"key":24,"text":442,"correct":22},"封闭的避难层应设置独立的机械防烟系统",{"key":28,"text":444,"correct":22},"通向避难层的疏散楼梯应使人员需经过避难层方能上下",{"key":31,"text":446,"correct":22},"避难层可兼做设备层",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":20,"analysis":33},932073,"（2017真题）下列多层厂房中，设置机械加压送风系统的封闭楼梯间应采用乙级防火门的是（）。",[451,453,455,457],{"key":20,"text":452,"correct":26},"服装加工厂房",{"key":24,"text":454,"correct":22},"机械修理厂",{"key":28,"text":456,"correct":22},"汽车厂总装厂房",{"key":31,"text":458,"correct":22},"金属冶炼厂房",{"id":460,"libraryId":5,"type":36,"typeLabel":37,"stem":461,"options":462,"answer":473,"analysis":33},932074,"（2016真题）下列关于建筑中疏散门的做法中，正确的有()。",[463,465,467,469,471],{"key":20,"text":464,"correct":26},"建筑高度为31.5m的办公楼，封闭楼梯间在每层均设置甲级防火门并向疏散方向开启，防火门完全开启时不减少楼梯平台的有效宽度",{"key":24,"text":466,"correct":22},"宾馆首层大堂480㎡,在南北两面均设置1个净宽1.8m并双向开启的普通玻璃外门和1个直径3m的转门",{"key":28,"text":468,"correct":26},"建筑面积为360㎡的单层制氧机房，设置2个净宽1.4m的外开门",{"key":31,"text":470,"correct":22},"位于走道两侧的教室，每间教室的建筑面积为120㎡，核定人数70人，设置两个净宽为1.2m并向教室内开启的门",{"key":49,"text":472,"correct":26},"建筑面枳为1500㎡的单层轮胎仓库，在墙的外侧设置2个净宽4m的推拉门","ACE",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":28,"analysis":33},932075,"（2016真题）某建筑高度为300m的办公建筑，首层室内地面标高为±0.000m，消防车登高操作场地的地面标高为-0.600m，首层层高为6.0m，地上其余楼层的层高均为4.8m。下列关于该建筑避难层的做法中，错误的是（）。",[478,480,482,484],{"key":20,"text":479,"correct":22},"第二个避难层与第一个避难层相距10层设置",{"key":24,"text":481,"correct":22},"第一个避难层的避难净面积按其担负的避难人数乘以0.25㎡\u002F人计算确定",{"key":28,"text":483,"correct":26},"将第一个避难层设置在第十二层",{"key":31,"text":485,"correct":22},"第二个避难层的避难净面积按其负担的避难人数乘以0.2㎡\u002F人计算确定",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":28,"analysis":33},932076,"（2016真题）下列建筑中的消防应急照明备用电源的连续供电时间按1.0h设置，其中不符合规范要求的是（）。",[490,492,494,496],{"key":20,"text":491,"correct":22},"医疗建筑、老年人建筑",{"key":24,"text":493,"correct":22},"总建筑面积大于100000㎡的商业建筑",{"key":28,"text":495,"correct":26},"建筑高度大于100m的住宅建筑",{"key":31,"text":497,"correct":22},"总建筑面积大于20000㎡的地下汽车库",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":28,"analysis":33},932077,"（2015真题）某商业建筑，地上4 层、地下2 层，耐火等级一级，建筑高度为20.6m。地上各层为百货、小商品和餐饮，地下一层为超市，地下二层为汽车库。地下一层设计疏散人数为1500 人，地上一至三层每层设计疏散人数为2000 人，四层设计疏散人数为1800 人。地上一至三层疏散楼梯的最小总净宽度应是（）m。",[502,504,506,508],{"key":20,"text":503,"correct":22},"13",{"key":24,"text":505,"correct":22},"15",{"key":28,"text":507,"correct":26},"20",{"key":31,"text":509,"correct":22},"18",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":24,"analysis":33},932078,"（2017真题）某7层商业综合体建筑，裙房与塔楼连通部位采用防火卷帘分隔。裙房地上3层，地下2层，建筑面积35000m2，耐火等级为一级，商业业务包括商业营业厅及餐厅等。裙房第三层的百人疏散宽度指标应为（）m\u002F百人。",[514,516,518,520],{"key":20,"text":515,"correct":22},"0.65",{"key":24,"text":517,"correct":26},"1.00",{"key":28,"text":519,"correct":22},"0.75",{"key":31,"text":521,"correct":22},"0.85",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":31,"analysis":33},932079,"（2016真题）下列关于建筑安全出口或疏散楼梯间的做法中，错误的是（ ）",[526,528,530,532],{"key":20,"text":527,"correct":22},"位于地下一层，总建筑面积为 1000 ㎡的卡拉 OK 厅和舞厅，设置了 3 个净宽度均为 2m 的安全出口",{"key":24,"text":529,"correct":22},"每层为一个防火分区且每层使用人数不超过 180 人的多层制衣厂，设置了 2 座梯段净宽度均为 1.2m 的封闭楼梯间",{"key":28,"text":531,"correct":22},"每层办公楼的每层使用人数为 60 人，设置了 2 座防烟疏散楼梯间，楼梯间的净宽度及楼梯间在首层的门的净宽度均为 1.2m",{"key":31,"text":533,"correct":26},"单层二级耐火等级且设置自动喷水灭火系统的电影院，其中一个1000 座的观众厅设置了 4 个净宽度均为 1.50m 的安全出口",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":24,"analysis":33},932080,"（2017真题）避难走道楼板及防火隔墙的最低耐火极限应分别为（ ）。",[538,540,542,544],{"key":20,"text":539,"correct":22},"1.00h、2.00h",{"key":24,"text":541,"correct":26},"1.50h、3.00h",{"key":28,"text":543,"correct":22},"1.50h、2.00h",{"key":31,"text":545,"correct":22},"1.00h、3.00h",{"id":547,"libraryId":5,"type":36,"typeLabel":37,"stem":548,"options":549,"answer":419,"analysis":33},932081,"（2015真题）下列无敞开式外廊的建筑中，可设置封闭楼梯间的有（）。",[550,552,554,556,558],{"key":20,"text":551,"correct":26},"4层且建筑高度为21m的医院门诊楼",{"key":24,"text":553,"correct":26},"3层且建筑高度为12m、每层建筑面积为500㎡的小型商店",{"key":28,"text":555,"correct":26},"3层且建筑高度为19.8m的纺织厂房",{"key":31,"text":557,"correct":26},"6层且建筑高度为21.6m的办公楼",{"key":49,"text":559,"correct":22},"宾馆建筑下部设置的3层地下设备房和汽车库",{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":28,"analysis":33},932082,"（2017真题）关于高层办公楼疏散楼梯设置的说法中，错误的是（ ）。",[564,566,568,570],{"key":20,"text":565,"correct":22},"疏散楼梯间内不得设置烧水间、可燃材料储存室、垃圾道",{"key":24,"text":567,"correct":22},"疏散楼梯间不得设置影响疏散的凸出物或其他障碍物",{"key":28,"text":569,"correct":26},"疏散楼梯间必须靠外墙设置并开设外窗",{"key":31,"text":571,"correct":22},"公共建筑的疏散楼梯间不得敷设可燃气体管道",{"id":573,"libraryId":5,"type":36,"typeLabel":37,"stem":574,"options":575,"answer":356,"analysis":33},932083,"（2015真题）某纺织厂房，地上 3 层，耐火等级为二级，建筑高度 18m，建筑面积 16800 ㎡，设置 4 部疏散楼梯间。下列关于疏散楼梯间的做法正确的有（ ）。",[576,578,580,582,584],{"key":20,"text":577,"correct":26},"厂房的3 部疏散楼梯间靠外墙布置，并具备天然采光和自然通风条件，设置为封闭楼梯间",{"key":24,"text":579,"correct":22},"厂房的1 部疏散楼梯间不能自然通风采光，因厂房的建筑高度小于32m，防烟楼梯间可不设置前室",{"key":28,"text":581,"correct":26},"厂房的1 部疏散楼梯间不能自然通风采光，将其改为防烟楼梯间",{"key":31,"text":583,"correct":26},"封闭楼梯间的门应采用乙级防火门",{"key":49,"text":585,"correct":22},"其中1 部防烟楼梯间开设防火门确有困难，采用防火卷帘代替",{"id":587,"libraryId":5,"type":15,"typeLabel":16,"stem":588,"options":589,"answer":31,"analysis":33},932084,"（2017真题）关于疏散楼梯间设置的做法，错误的是（）。",[590,592,594,596],{"key":20,"text":591,"correct":22},"2层展览建筑无自然通风条件的封闭楼梯间，在楼梯间直接设置机械加压送风系统",{"key":24,"text":593,"correct":22},"与高层办公主体建筑之间设置防火墙的商业裙房，其疏散楼梯间采用封闭楼梯间",{"key":28,"text":595,"correct":22},"建筑高度为33m的住宅建筑，户门均采用乙级防火门，其疏散楼梯间采用敞开楼梯间",{"key":31,"text":597,"correct":26},"建筑高度为32m，标准层建筑面积为1500m2的电信楼，其疏散楼梯间采用封闭楼梯间",{"id":599,"libraryId":5,"type":15,"typeLabel":16,"stem":600,"options":601,"answer":28,"analysis":33},932085,"（2015真题）某超高层办公建筑，建筑总高度为180m，共设置有3 个避难层。投入使用前对避难层进行检查，下列检查结果中，正确的是（ ）。",[602,604,606,608],{"key":20,"text":603,"correct":22},"设置了独立的机械排烟设施",{"key":24,"text":605,"correct":22},"第一个避难层的楼地面与灭火救援地地面的高差为55m",{"key":28,"text":607,"correct":26},"通向避难层的避难楼梯在避难层进行了分隔",{"key":31,"text":609,"correct":22},"避难层兼作设备层，避难区域与设备管道采用耐火极限1.0h 的防火墙分隔",{"id":611,"libraryId":5,"type":15,"typeLabel":16,"stem":612,"options":613,"answer":31,"analysis":33},932086,"（2016真题）建筑高度超过 100m 的公共建筑应设置避难层，下列有关避难层设置的说法中，错误的是（ ）。",[614,615,616,617],{"key":20,"text":442,"correct":22},{"key":24,"text":444,"correct":22},{"key":28,"text":446,"correct":22},{"key":31,"text":440,"correct":26},{"id":619,"libraryId":5,"type":15,"typeLabel":16,"stem":620,"options":621,"answer":20,"analysis":33},932087,"（2015真题）某高度为120m的高层办公建筑，其消防应急照明备用电源的连续供电时间不应低于（）min。",[622,624,625,627],{"key":20,"text":623,"correct":26},"90",{"key":24,"text":507,"correct":22},{"key":28,"text":626,"correct":22},"30",{"key":31,"text":628,"correct":22},"60",{"id":630,"libraryId":5,"type":15,"typeLabel":16,"stem":631,"options":632,"answer":31,"analysis":33},932088,"（2015真题）某多功能建筑，建筑高度为54.8m，2座楼梯间分别位于“一”字形内走廊的尽端，楼梯间形式和疏散宽度符合相关规范规定。地下一层建筑面积为2600m2，用途为餐厅、设备房；地上共14层，建筑面积为24000m2，用途为歌舞娱乐、宾馆、办公。该建筑按照规范要求设置建筑消防设施。下列关于该建筑房间疏散门的设置中，错误的是（ ）。",[633,635,637,639],{"key":20,"text":634,"correct":22},"九至十四层每层的会议室相邻两个疏散门最近边缘之间的水平距离为6m",{"key":24,"text":636,"correct":22},"位于地下一层的一个建筑面积为50m2、使用人数为10人的小餐厅，设置1个向内开启的疏散门",{"key":28,"text":638,"correct":22},"位于三层的一个建筑面积为80m2、使用人数为50人的会议室，设置2个向内开启的疏散门",{"key":31,"text":640,"correct":26},"位于一层的一个建筑面积为60m2、使用人数为16人的录像厅，设置1个向外开启的疏散门",{"id":642,"libraryId":5,"type":15,"typeLabel":16,"stem":643,"options":644,"answer":20,"analysis":33},932089,"（2017真题）大学生集体宿舍楼疏散走道内设置的疏散照明，其地面水平照度不应低于（）lx。",[645,647,649,651],{"key":20,"text":646,"correct":26},"3.0",{"key":24,"text":648,"correct":22},"1.0",{"key":28,"text":650,"correct":22},"5.0",{"key":31,"text":652,"correct":22},"10.0",[654,657,660,663,666,669],{"id":15,"name":655,"category":7,"favorite":656},"领导干部任职前廉政法规知识测试题",92,{"id":658,"name":659,"category":7,"favorite":15},595,"建筑结构与设备",{"id":661,"name":662,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":664,"name":665,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":667,"name":668,"category":7,"favorite":8},534,"BIM工程师",{"id":670,"name":668,"category":7,"favorite":8},535]