[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-58":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":592},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,58,50,2960,[13,34,46,58,70,81,93,105,116,126,138,147,159,171,183,195,205,214,222,234,242,254,266,278,290,302,314,322,334,346,354,366,377,389,401,413,425,437,449,460,472,484,496,508,520,532,544,556,568,580],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},934604,1,"单选题","一座一类高层民用建筑，其地上某层设有两个防火分区，每个防火分区均有一个疏散楼梯，两分区之间的防火墙上有甲级防火门相连通，如果不设自动灭火系统，此层建筑面积不应大于（ ）m2。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","3000",true,{"key":24,"text":25,"correct":26},"B","1500",false,{"key":28,"text":29,"correct":26},"C","2500",{"key":31,"text":32,"correct":26},"D","6000","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},934606,"敞开式外廊的二级耐火等级的多层教学楼、位于两个楼梯之间的教室，其房门至楼梯间最大距离为（ ）m。",[38,40,42,44],{"key":20,"text":39,"correct":26},"22",{"key":24,"text":41,"correct":26},"30",{"key":28,"text":43,"correct":26},"35",{"key":31,"text":45,"correct":22},"40",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},934608,"下列耐火等级为一二级的多层民用建筑中的大房间，室内最远一点到房门的最大距离，哪条是错误的（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"医院病房楼中位于两座楼梯间之间的大房间，其室内最远一点到房门的最大距离为20m",{"key":24,"text":53,"correct":26},"医院病房楼中位于走道尽端的大房间，其室内最远一点到房门的最大距离为20m",{"key":28,"text":55,"correct":22},"教学楼中位于两座楼梯间之间的大房间，其室内最远一点到房门的最大距离为35m",{"key":31,"text":57,"correct":26},"办公楼中位于袋形走道两侧的大房间，其室内最远一点到房间的最大距离为22m",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},934610,"高层医院建筑中其首层每个疏散外门的净宽不应小于（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"1.10m",{"key":24,"text":65,"correct":22},"1.30m",{"key":28,"text":67,"correct":26},"1.50m",{"key":31,"text":69,"correct":26},"1.60m",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},934612,"高层医院的病房部设有自动喷淋系统，分位于两个安全出口之间的房间门至最近的外部出口或楼梯间的最大距离为（ ）m。",[74,76,78,80],{"key":20,"text":75,"correct":26},"15",{"key":24,"text":77,"correct":26},"20",{"key":28,"text":79,"correct":26},"24",{"key":31,"text":41,"correct":22},{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":28,"analysis":33},934614,"某超高层综合楼，地下三层，层高均为4m。地上50层，其中1-4层为商业用途，层高7m;5～49层为办公用房，层高均为4.5m;50层为高位消防水池、水泵房、空调机房等设备用房，层高4.8m。室外设计地面低于首层地面0.3m。根据《建筑设计防火规范》（GB50016-2014），该建筑高度为（ ）m。",[85,87,89,91],{"key":20,"text":86,"correct":26},"230.5",{"key":24,"text":88,"correct":26},"230.8",{"key":28,"text":90,"correct":22},"235.6",{"key":31,"text":92,"correct":26},"235.3",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":28,"analysis":33},934616,"某居住小区，其边缘某高层住宅建筑地上31层，地下2层。地上一层为高度4.5m的绿化架空层，架空层地面至平屋面面层的高度为97.5m，地下室顶板高出室外设计地面1.0m。根据《建筑设计防火规范》（GB50016-2014），该建筑高度为（ ）m。",[97,99,101,103],{"key":20,"text":98,"correct":26},"98.5",{"key":24,"text":100,"correct":26},"93",{"key":28,"text":102,"correct":22},"97.5",{"key":31,"text":104,"correct":26},"94",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":24,"analysis":33},934618,"某商业中心地上4层，地下1层，层高均为5m，耐火等级一级，建筑屋面为平屋面。室外设计地面低于地上一层地面0.3m。根据《建筑设计防火规范》（GB50016-2014），该建筑高度为（ ）m。",[109,111,113,114],{"key":20,"text":110,"correct":26},"25.3",{"key":24,"text":112,"correct":22},"20.3",{"key":28,"text":77,"correct":26},{"key":31,"text":115,"correct":26},"25",{"id":117,"libraryId":5,"type":15,"typeLabel":16,"stem":118,"options":119,"answer":24,"analysis":33},934620,"某商业中心地上4层，地下1层，耐火等级一级，建筑屋面为坡屋面，首层地面至其檐口的高度为20m，檐口至屋脊的高度为4m，室外设计地面低于地上一层地面0.3m。根据《建筑设计防火规范》（GB50016-2014），该建筑高度为（ ）m。",[120,121,123,124],{"key":20,"text":77,"correct":26},{"key":24,"text":122,"correct":22},"22.3",{"key":28,"text":39,"correct":26},{"key":31,"text":125,"correct":26},"24.3",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":31,"analysis":33},934622,"下列关于防火间距测量的叙述中，哪项是错误的（ ）。",[130,132,134,136],{"key":20,"text":131,"correct":26},"选择相对较近处测量间距，测量值的允许负偏差不得大于规定值的5%",{"key":24,"text":133,"correct":26},"建筑之间：从外墙的最近水平距离进行测量，当外墙有凸出的可燃或难燃构件时，从凸出部分的外缘进行测量",{"key":28,"text":135,"correct":26},"建筑与储罐之间的防火间距，按建筑外墙至储罐外壁的最近水平距离测量",{"key":31,"text":137,"correct":22},"铁路与建筑物的防火间距，从铁路线外缘距建筑外墙的最小水平距离测量",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":24,"analysis":33},934624,"一座二级耐火等级的非高层教学楼，平面为内走廊式布置，楼梯间为开敞式，袋形走道两侧的房门至楼梯间的最大距离应为（ ）m。",[142,143,144,145],{"key":20,"text":39,"correct":26},{"key":24,"text":77,"correct":22},{"key":28,"text":115,"correct":26},{"key":31,"text":146,"correct":26},"18",{"id":148,"libraryId":5,"type":15,"typeLabel":16,"stem":149,"options":150,"answer":24,"analysis":33},934626,"《建筑内部装修设计防火规范》规定，隔断系指不到顶的隔断，到顶的固定隔断装修应与（ ）规定相同。",[151,153,155,157],{"key":20,"text":152,"correct":26},"顶棚",{"key":24,"text":154,"correct":22},"墙面",{"key":28,"text":156,"correct":26},"地面",{"key":31,"text":158,"correct":26},"柱面",{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":161,"options":162,"answer":20,"analysis":33},934628,"《建筑内部装修设计防火规范》规定，装修材料按其使用部位和功能，可划分为顶棚装修材料、墙面装修材料、地面装修材料、（ ）、固定家具、装饰织物、其他装饰材料七类。",[163,165,167,169],{"key":20,"text":164,"correct":22},"隔断装修材料",{"key":24,"text":166,"correct":26},"柱面装修材料",{"key":28,"text":168,"correct":26},"移动家具",{"key":31,"text":170,"correct":26},"吊顶装修材料",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":24,"analysis":33},934630,"《建筑内部装修设计防火规范》GB50222-95规定，装修材料按其燃烧性能应划分为（ ）。",[175,177,179,181],{"key":20,"text":176,"correct":26},"三级",{"key":24,"text":178,"correct":22},"四级",{"key":28,"text":180,"correct":26},"五级",{"key":31,"text":182,"correct":26},"六级",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":28,"analysis":33},934631,"《建筑内部装修设计防火规范》中装修材料的燃烧性能等级，应按本规范的规定，由专业检测机构检测确定。（ ）装修材料可不进行检测。",[187,189,191,193],{"key":20,"text":188,"correct":26},"B1级",{"key":24,"text":190,"correct":26},"B2级",{"key":28,"text":192,"correct":22},"B3级",{"key":31,"text":194,"correct":26},"A级",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":20,"analysis":33},934633,"《建筑内部装修设计防火规范》规定，当胶合板表面涂覆（ ）饰面型防火涂料时，可做为B1级装修材料使用。",[199,201,203,204],{"key":20,"text":200,"correct":22},"一级",{"key":24,"text":202,"correct":26},"二级",{"key":28,"text":176,"correct":26},{"key":31,"text":178,"correct":26},{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":20,"analysis":33},934635,"当胶合板表面涂覆一级饰面型防火涂料时，可作为（ ）级装修材料使用。当胶合板用于顶棚和墙面装修并且不内含电器、电线等物体时，宜仅在胶合板外表面涂覆防火涂料；当胶合板用于顶棚和墙面装修并且内含电器、电线等物体时，胶合板的内、外表面以及相应的木龙骨应涂覆防火涂料，或采用阻燃浸渍处理达到（ ）级。 A.B1，B1",[209,211,213],{"key":20,"text":210,"correct":22},"B2，B2",{"key":24,"text":212,"correct":26},"B1，A",{"key":28,"text":20,"correct":26},{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":24,"analysis":33},934637,"《建筑内部装修设计防火规范》规定，施涂于A级基材上的无机装饰涂料，可做为A级装修材料使用；施涂于A级基材上，湿涂覆比小于1.5kg\u002Fm2的有机装饰涂料，可做为（ ）装修材料使用。",[218,219,220,221],{"key":20,"text":194,"correct":26},{"key":24,"text":188,"correct":22},{"key":28,"text":190,"correct":26},{"key":31,"text":192,"correct":26},{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":20,"analysis":33},934639,"《建筑内部装修设计防火规范》规定，复合型装修材料应由专业检测机构进行（ ）并划分其燃烧性能等级。",[226,228,230,232],{"key":20,"text":227,"correct":22},"整体测试",{"key":24,"text":229,"correct":26},"分层测试",{"key":28,"text":231,"correct":26},"全面测试",{"key":31,"text":233,"correct":26},"抽样测试",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":24,"analysis":33},934640,"《建筑内部装修设计防火规范》规定，大中型电子计算机房、中央控制室、电话总机房等放置特殊贵重设备的房间，地面及其他装修应采用不低于（ ）的装修材料。",[238,239,240,241],{"key":20,"text":194,"correct":26},{"key":24,"text":188,"correct":22},{"key":28,"text":190,"correct":26},{"key":31,"text":192,"correct":26},{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":24,"analysis":33},934642,"《建筑内部装修设计规范》规定，建筑材料的燃烧性能分为（ ）个等级。",[246,248,250,252],{"key":20,"text":247,"correct":26},"3",{"key":24,"text":249,"correct":22},"4",{"key":28,"text":251,"correct":26},"5",{"key":31,"text":253,"correct":26},"6",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":28,"analysis":33},934644,"《住宅建筑规范》中，二级耐火等级住宅建筑的防火墙采用耐火极限不低于（ ）h的不燃性材料。",[258,260,262,264],{"key":20,"text":259,"correct":26},"2.00",{"key":24,"text":261,"correct":26},"2.50",{"key":28,"text":263,"correct":22},"3.00",{"key":31,"text":265,"correct":26},"4.00",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":24,"analysis":33},934646,"在18层单元式住宅中，单元之间的墙应为耐火极限不低于（ ）h的不燃性墙体，并应砌至屋面板底部。",[270,272,274,276],{"key":20,"text":271,"correct":26},"1.5",{"key":24,"text":273,"correct":22},"2.0",{"key":28,"text":275,"correct":26},"3.0",{"key":31,"text":277,"correct":26},"4.0",{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":24,"analysis":33},934648,"一个800人的电影院观众厅，在平整地面的门厅和休息厅向外疏散，则外门的总宽度最小为（ ）m。",[282,284,286,288],{"key":20,"text":283,"correct":26},"4.8",{"key":24,"text":285,"correct":22},"5.2",{"key":28,"text":287,"correct":26},"6.0",{"key":31,"text":289,"correct":26},"7.2",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":31,"analysis":33},934650,"某建筑高度98.9m的大楼，使用功能为办公、宾馆、商业和娱乐。一至四层的裙房设有营业厅和办公室；地下一层夜总会疏散走道两侧和尽端设有5个卡拉0K小包间；营业厅的2个疏散门需要通过疏散走道至疏散楼梯间。该建筑按照规范要求设置消防设施。下列建筑内疏散走道的设计中，错误的是（ ）。",[294,296,298,300],{"key":20,"text":295,"correct":26},"办公区域疏散走道两侧的隔墙采用加气混凝土块砌筑，耐火极限为1.50h",{"key":24,"text":297,"correct":26},"宾馆区域疏散走道采用轻钢龙骨纸面石膏板吊顶，耐火极限为0.30h",{"key":28,"text":299,"correct":26},"夜总会疏散走道尽端房间房门至最近的安全出口的疏散走道长度为11m",{"key":31,"text":301,"correct":22},"裙房内营业厅的疏散门至最近的安全出口的疏散走道长度为15m",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":24,"analysis":33},934652,"对防火卷帘进行自重恒速下降功能检查时，防火卷帘卷门机具有依靠防火卷帘自重恒速下降的功能，操作臂力不得大于（ ）N。",[306,308,310,312],{"key":20,"text":307,"correct":26},"80",{"key":24,"text":309,"correct":22},"70",{"key":28,"text":311,"correct":26},"100",{"key":31,"text":313,"correct":26},"50",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":20,"analysis":33},934654,"有一民用建筑，地上4层，地下1层，地下1层净高为5m且室内外地坪高差为3m，该建筑地下1层的耐火等级不低于（ ）。",[318,319,320,321],{"key":20,"text":200,"correct":22},{"key":24,"text":202,"correct":26},{"key":28,"text":176,"correct":26},{"key":31,"text":178,"correct":26},{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":20,"analysis":33},934656,"某市政府办公大楼，建筑高度26m，建筑层数为7层，该建筑分类应为（ ）公共建筑。",[326,328,330,332],{"key":20,"text":327,"correct":22},"一类高层",{"key":24,"text":329,"correct":26},"二类高层",{"key":28,"text":331,"correct":26},"单多层",{"key":31,"text":333,"correct":26},"其它",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":31,"analysis":33},934658,"某百货大楼，地上4层，局部6层，建筑高度36m，建筑面积28700m2，下列做法中，错误的是（ ）。",[338,340,342,344],{"key":20,"text":339,"correct":26},"防火墙上的防火门采用向疏散方向开启的平开门，并在关闭后能从任何一侧手动开启",{"key":24,"text":341,"correct":26},"办公区走道上的甲级防火门采用常开防火门，在火灾情况下能自动关闭并反馈信号",{"key":28,"text":343,"correct":26},"变形缝附近的防火门设置在六层建筑一侧",{"key":31,"text":345,"correct":22},"因消防电梯前室的门洞尺寸较大，防火门使用和安装不便，改用防火卷帘",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":28,"analysis":33},934660,"根据《建筑设计防火规范》（GB50016-2014）的规定，某占地面积为400m2的单层花生油精炼厂房（层高12m）的耐火等级不应低于（ ）。",[350,351,352,353],{"key":20,"text":200,"correct":26},{"key":24,"text":202,"correct":26},{"key":28,"text":176,"correct":22},{"key":31,"text":178,"correct":26},{"id":355,"libraryId":5,"type":15,"typeLabel":16,"stem":356,"options":357,"answer":31,"analysis":33},934662,"某机械加工企业需在生产车间内设置中间仓库储存硝酸。下列设置要求中，符合规范规定的有（ ）。",[358,360,362,364],{"key":20,"text":359,"correct":26},"中间仓库靠外墙布置，采用防火墙及耐火极限不低于1.0h的楼板与其它部位分隔，硝酸储量不超过1昼夜用量",{"key":24,"text":361,"correct":26},"中间仓库靠外墙布置，采用耐火极限不低于2.5h的防火隔墙及1.5h的楼板与其它部位分隔，硝酸储量不超过1昼夜用量",{"key":28,"text":363,"correct":26},"中间仓库靠外墙布置，采用耐火极限不低于2.0h的防火隔墙和1.5h的楼板与生产部位分隔，硝酸储量不超过1昼夜用量",{"key":31,"text":365,"correct":22},"中间仓库靠外墙布置，采用防火墙及耐火极限不低于1.5h的不燃性楼板与其它部位分隔，硝酸储量不超过1昼夜用量",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":20,"analysis":33},934664,"某住宅楼建筑地上7层，建筑高度24m，建筑内的疏散走道和安全出口的门厅，其顶棚装饰材料应采用（ ）级装修材料。",[370,371,373,375],{"key":20,"text":20,"correct":22},{"key":24,"text":372,"correct":26},"B1",{"key":28,"text":374,"correct":26},"B2",{"key":31,"text":376,"correct":26},"B3",{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":31,"analysis":33},934666,"某民用建筑地上19层，地下3层，消防水泵房设置在地下二层，关于消防水泵房的内部装修材料，下列说法正确的是（ ）。",[381,383,385,387],{"key":20,"text":382,"correct":26},"顶棚应为A级",{"key":24,"text":384,"correct":26},"顶棚和墙面应为A级，其他部位不低于B1",{"key":28,"text":386,"correct":26},"顶棚、墙面和地面应为A级，其他部位不低于B1级",{"key":31,"text":388,"correct":22},"内部所有装修材料均应为A级",{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":28,"analysis":33},934668,"下列建筑或楼层中，不需要对疏散楼梯、疏散门进行改造就能设置为歌舞娱乐游艺放映场所的是（ ）。",[393,395,397,399],{"key":20,"text":394,"correct":26},"建筑面积为500m2且埋深为5m的地下室，设1个安全出口及一个金属竖向梯",{"key":24,"text":396,"correct":26},"防火分区建筑面积为50m2且设置1个安全出口的地下室",{"key":28,"text":398,"correct":22},"建筑面积为50m2，经常停留人数不超过15人且设置1个疏散门的地下房间",{"key":31,"text":400,"correct":26},"耐火等级为二级，每层建筑面积均为200m2，第二、三层的人数之和不超过50人，至设置1部疏散楼梯的3层建筑",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":24,"analysis":33},934678,"下列关于消防电梯前室或合用前室使用面积的说法，错误的是（ ）。",[405,407,409,411],{"key":20,"text":406,"correct":26},"某住宅的疏散楼梯采用防烟楼梯间，该楼梯间前室与消防电梯前室合用时，合用前室的使用面积为7㎡",{"key":24,"text":408,"correct":22},"某住宅的疏散楼梯采用剪刀楼梯间，该楼梯问的共用前室与消防电梯的前室合用时，合用前室的使用面积为11㎡",{"key":28,"text":410,"correct":26},"某公共建筑的疏散楼梯采用防烟楼梯间，该楼梯间前室与消防电梯前室合用时，合用前室的使用面积为13㎡",{"key":31,"text":412,"correct":26},"某高层厂房的疏散楼梯采用防烟楼梯间，该楼梯问前室与消防电梯前室合用时，合用前室的使用面积为11㎡",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":31,"analysis":33},934680,"某商业建筑，建筑屋面为坡屋面，建筑室内设计地面标高±0.00，室外设计地面标高-0.1m，檐口的标高+60m，屋脊的标高+63m，该建筑的建筑高度为（ ）m。",[417,419,421,423],{"key":20,"text":418,"correct":26},"60",{"key":24,"text":420,"correct":26},"63",{"key":28,"text":422,"correct":26},"61.5",{"key":31,"text":424,"correct":22},"61.6",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":28,"analysis":33},934682,"民用建筑类别是根据建筑高度、使用功能、火灾危险性和扑救难易程度进行确定，主要分为住宅建筑和公共建筑两大类。下列关于民用建筑类别划分说法中，不正确的是（ ）。",[429,431,433,435],{"key":20,"text":430,"correct":26},"在防火方面，宿舍、公寓等防火要求按公共建筑的有关规定执行",{"key":24,"text":432,"correct":26},"对建筑高度大于24m的单层公共建筑主要使用功能为单层时，该建筑为单层建筑",{"key":28,"text":434,"correct":22},"对建筑高度大于24m的单层公共建筑主要使用功能难以区分时，并且单层部分与多层或高层部分采用防火墙分开时，该建筑为多层或高层建筑",{"key":31,"text":436,"correct":26},"30m高层医疗建筑，其划分为一类高公共建筑",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":31,"analysis":33},934684,"某住宅建筑，建筑屋面为坡屋面，建筑室外设计地面标高为±0.000m，屋脊标高为+58.000m，檐口标高为54.000m，首层室内地面标高为+1.500m，则该住宅建筑的建筑高度为（ ）m。",[441,443,445,447],{"key":20,"text":442,"correct":26},"58m",{"key":24,"text":444,"correct":26},"54m",{"key":28,"text":446,"correct":26},"56m",{"key":31,"text":448,"correct":22},"54.5m",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":31,"analysis":33},934686,"某新建剧场，设计容纳人数为2800人，按2min内人员疏散完毕的原则设计建筑的安全疏散，每股人流的通过能力为40人\u002Fmin，该剧场每个出口的最小宽度宜为（ ）m。",[453,455,457,458],{"key":20,"text":454,"correct":26},"1.6",{"key":24,"text":456,"correct":26},"1.8",{"key":28,"text":273,"correct":26},{"key":31,"text":459,"correct":22},"2.2",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":31,"analysis":33},934687,"下列关于装修材料分级分类的叙述中，错误的是（ ）。",[464,466,468,470],{"key":20,"text":465,"correct":26},"石膏板燃烧性能为A级，但纸面石膏板和纤维石膏板燃烧性能为B1级",{"key":24,"text":467,"correct":26},"难燃木材燃烧性能为B1级，但天然木材燃烧性能为B2级",{"key":28,"text":469,"correct":26},"硬PVC塑料地板燃烧性能为B1级，但半硬质PVC塑料地板燃烧性能为B2级",{"key":31,"text":471,"correct":22},"经阻燃处理的织物燃烧性能都为B2级",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":31,"analysis":33},934689,"某商业楼底面建筑投影为长方形，呈东、西向布置，地上6层，建筑高度24m，二级耐火等级，每层建筑面积均为8000m2，每层均按建筑面积平均划分为东、西两个防火分区，每层使用功能均为百货商场，已按现行有关国家工程建设消防技术标准的规定设置消防设施。该建筑每层东侧防火分区利用通向相邻西侧防火分区的甲级防火门作为安全出口的疏散净宽度均为5m。请问该建筑地上二层东侧防火分区内直通室外安全出口的最小疏散净宽度应为（ ）m。",[476,478,480,482],{"key":20,"text":477,"correct":26},"34.4",{"key":24,"text":479,"correct":26},"22.2",{"key":28,"text":481,"correct":26},"17.2",{"key":31,"text":483,"correct":22},"12.2",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":20,"analysis":33},934691,"下列关于建筑高度的叙述中，正确的是（ ）。",[488,490,492,494],{"key":20,"text":489,"correct":22},"某商业中心地上4层，地下1层，耐火等级一级，建筑屋面为坡屋面，地上一层地面至其檐口的高度为20m，地上一层地面至其屋脊的高度为24m，室外设计地面低于地上一层地面0.3m，则其建筑高度为22.3m",{"key":24,"text":491,"correct":26},"某6层酒店建筑建于台阶式地坪上，按台阶梯段分成甲、乙两部分，两部分之间有防火隔墙分隔，各自有符合规范规定的安全出口，且可沿建筑的两个长边设置贯通式或尽头式消防车道，其中甲部分室外地面标高为0.00m，屋面面层标高为24.00m;乙部分室外地面标高为4.00m，屋面面层标高为29.00m，则该建筑高度为25m",{"key":28,"text":493,"correct":26},"某酒店建筑，一层层高4m（室内外地面高差为0.3m），为大堂、餐厅、洗衣房，二至五层层高3.2m，均为客房，屋顶设有局部突出屋顶的辅助用房面积占屋面面积的1\u002F4，高度均为4.5m，则该酒店建筑高度为21.6m，层数为6层",{"key":31,"text":495,"correct":26},"某多层住宅建筑，一层为高度2.2m的自行车库，自行车库地面至平屋面面层的高度为26.2m，室外设计地面低于自行车库地面1.0m，则该住宅建筑高度为23m",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":31,"analysis":33},934693,"对工业建筑进行防火检查时，应注意检查工业建筑的火灾危险性、耐火等级和建筑面积，在检查的下列工业建筑中，可以采用三级耐火等级的是（ ）。",[500,502,504,506],{"key":20,"text":501,"correct":26},"建筑面积为1500m2的金属冶炼车间",{"key":24,"text":503,"correct":26},"建筑面积为350m2氨压缩机房",{"key":28,"text":505,"correct":26},"蒸发量为7t\u002Fh的燃煤锅炉房",{"key":31,"text":507,"correct":22},"独立建造的建筑面积为280m2的单层制氧车间",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":20,"analysis":33},934695,"下列关于建筑中疏散门宽度的说法中，错误的是（ ）。（2016-能力）",[512,514,516,518],{"key":20,"text":513,"correct":22},"电影院观众厅的疏散门，其净宽度不应小于1.2m",{"key":24,"text":515,"correct":26},"多层办公建筑内的疏散门，其净宽度不应小于0.9m",{"key":28,"text":517,"correct":26},"地下歌舞娱乐场所的疏散门，其总净宽应根据疏散人数按每100人不小于1.0m计算",{"key":31,"text":519,"correct":26},"住宅建筑的户门，其净宽度不应小于0.9m",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":28,"analysis":33},934697,"某燃煤锅炉房，锅炉的总蒸发量为20t\u002Fh，建筑高度10m，建筑面积5600m2，以下关于锅炉房防火设计，不正确的是（ ）。",[524,526,528,530],{"key":20,"text":525,"correct":26},"锅炉房的耐火等级不应低于二级",{"key":24,"text":527,"correct":26},"锅炉房与甲类厂房的防火间距不应小于30m",{"key":28,"text":529,"correct":22},"锅炉房与超高层办公楼的防火间距，当办公楼相邻外墙为防火墙，且墙上开口部位设置甲级防火窗，防火间距可为4m",{"key":31,"text":531,"correct":26},"燃气锅炉房应设置爆炸泄压设施，燃油或燃气锅炉房应设置独立的通风系统",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":20,"analysis":33},934699,"以下（ ）用房可设置在三级耐火等级的五层。",[536,538,540,542],{"key":20,"text":537,"correct":22},"办公用房",{"key":24,"text":539,"correct":26},"商店、展览馆",{"key":28,"text":541,"correct":26},"老年人活动场所及儿童活动场所",{"key":31,"text":543,"correct":26},"教学建筑",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":20,"analysis":33},934701,"以下建筑设计防火的论述中（ ）不准确。",[548,550,552,554],{"key":20,"text":549,"correct":22},"高层民用建筑内的商业营业厅，当设有火灾自动报警系统时，地上部分允许最大建筑面积为4000m2",{"key":24,"text":551,"correct":26},"高层民用建筑与其裙房之间设有防火墙时，其裙房的防火分区允许最大建筑面积不应大于2500m2",{"key":28,"text":553,"correct":26},"高层民用建筑内设有上、下连通的敞开楼梯、自动扶梯时，其防火分区的建筑面积应按上、下层相连通的建筑面积叠加计算",{"key":31,"text":555,"correct":26},"当自动扶梯周围设有耐火极限＞3h防火卷帘或水幕等分隔设施时，其面积可不叠加计算",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":20,"analysis":33},934703,"某市民广场下为二层地下商业，建筑面积近40000m2，下列关于该地下商业的平面布置，说法不正确的是（ ）。",[560,562,564,566],{"key":20,"text":561,"correct":22},"地上无建筑，地下可设置经营、存放和使用甲乙类火灾危险性物品的商店",{"key":24,"text":563,"correct":26},"地下二层设置电影院，最大观众厅的建筑面积为800m2",{"key":28,"text":565,"correct":26},"采用无门、窗、洞口的防火墙、耐火极限不低于2.0h的楼板分隔为两个建筑面积不大于20000m2的区域",{"key":31,"text":567,"correct":26},"疏散楼梯可采用防烟楼梯间",{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":20,"analysis":33},934705,"以下（ ）建筑可采用敞开楼梯作为疏散楼梯。",[572,574,576,578],{"key":20,"text":573,"correct":22},"与敞开式走廊直接相连的医疗建筑、旅馆、老年人建筑及类似使用功能的多层建筑",{"key":24,"text":575,"correct":26},"高层厂房",{"key":28,"text":577,"correct":26},"高层仓库",{"key":31,"text":579,"correct":26},"户门采用普通木门的建筑高度为30m的高层住宅",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":28,"analysis":33},934706,"建筑高度超过100m的公共建筑、住宅建筑应设置避难层。下列关于避难层设置的说法中，正确的是（ ）。",[584,586,588,590],{"key":20,"text":585,"correct":26},"所有普通电梯都应在避难层设出口",{"key":24,"text":587,"correct":26},"避难层都应设置机械防烟设施",{"key":28,"text":589,"correct":22},"避难层应设置消火栓、消防软管卷盘、消防应急专线电话、应急广播",{"key":31,"text":591,"correct":26},"人员疏散必须经过避难区方能上下",[593,596,599,602,605,608],{"id":15,"name":594,"category":7,"favorite":595},"领导干部任职前廉政法规知识测试题",92,{"id":597,"name":598,"category":7,"favorite":15},595,"建筑结构与设备",{"id":600,"name":601,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":603,"name":604,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":606,"name":607,"category":7,"favorite":8},534,"BIM工程师",{"id":609,"name":607,"category":7,"favorite":8},535]