[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-56":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":601},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,56,50,2960,[13,34,46,58,70,82,94,106,118,130,142,154,166,178,190,202,214,226,238,246,258,269,281,293,305,317,329,338,350,362,374,386,398,410,418,427,439,451,462,474,486,498,510,522,534,546,558,570,579,591],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},934463,1,"单选题","地下、半地下厂房或厂房的地下室、半地下室，当有多个防火分区相邻布置，并采用防火墙分隔时，每个防火分区可利用防火墙上通向相邻防火分区的甲级防火门作为第二安全出口，但每个防火分区必须至少有（ ）个直通室外的安全出口。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","1",true,{"key":24,"text":25,"correct":26},"B","2",false,{"key":28,"text":29,"correct":26},"C","3",{"key":31,"text":32,"correct":26},"D","4","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},934464,"仓库内每个防火分区通向疏散走道、楼梯或室外的出口不宜少于2个，当防火分区的建筑面积小于等于（ ）m2时，可设置1个。",[38,40,42,44],{"key":20,"text":39,"correct":26},"60",{"key":24,"text":41,"correct":26},"50",{"key":28,"text":43,"correct":22},"100",{"key":31,"text":45,"correct":26},"120",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},934465,"每座仓库的安全出口不应少于2个，当一座仓库的占地面积小于等于（ ）m2时，可设置1个安全出口。",[50,52,54,56],{"key":20,"text":51,"correct":26},"250",{"key":24,"text":53,"correct":22},"300",{"key":28,"text":55,"correct":26},"200",{"key":31,"text":57,"correct":26},"150",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},934466,"地下、半地下仓库或仓库的地下室、半地下室当有多个防火分区相邻布置，并采用防火墙分隔时，每个防火分区可利用防火墙上通向相邻防火分区的（ ）作为第二安全出口，但每个防火分区必须至少有1个直通室外的安全出口。",[62,64,66,68],{"key":20,"text":63,"correct":22},"甲级防火门",{"key":24,"text":65,"correct":26},"乙级防火门",{"key":28,"text":67,"correct":26},"丙级防火门",{"key":31,"text":69,"correct":26},"钢制防火门",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},934467,"高层仓库应设置（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":26},"防烟楼梯间",{"key":24,"text":77,"correct":26},"室外疏散楼梯间",{"key":28,"text":79,"correct":22},"封闭楼梯间",{"key":31,"text":81,"correct":26},"敞开楼梯间",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":28,"analysis":33},934468,"二级耐火等级建筑的主要构件，除（ ）为难燃性外，其余构件燃烧性能都是不燃性。",[86,88,90,92],{"key":20,"text":87,"correct":26},"墙体",{"key":24,"text":89,"correct":26},"隔墙",{"key":28,"text":91,"correct":22},"吊顶",{"key":31,"text":93,"correct":26},"地面",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},934469,"下列不属于一类高层民用建筑的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"建筑高度为58米的住宅建筑（含2层商业服务网点）",{"key":24,"text":101,"correct":26},"建筑高度为25米的医疗建筑",{"key":28,"text":103,"correct":26},"高层网局级电力调度楼",{"key":31,"text":105,"correct":22},"建筑高度为49米，每层面积为980m2的电信楼",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},934470,"下列说法不正确的是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"24m以上的住宅为高层",{"key":24,"text":113,"correct":26},"住宅超过54m时为一类高层",{"key":28,"text":115,"correct":26},"非单层公共建筑超过24m的建筑为高层",{"key":31,"text":117,"correct":26},"非单层公共建筑超过50m时为一类高层",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":31,"analysis":33},934471,"下列关于建筑物分类的叙述中，错误的是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":26},"宿舍、公寓等非住宅类居住建筑，根据公共建筑的相关要求确定其类别",{"key":24,"text":125,"correct":26},"对建筑高度大于24m的存在单层和多层组合建造的公共建筑，需要根据建筑的主要使用功能部分的层数和建筑高度来确定是高层还是单层建筑",{"key":28,"text":127,"correct":26},"当难以区分建筑的主要功能，并且单层部分与多层或高层部分又没有采用防火墙分开时，则将该建筑确定为多层或高层建筑",{"key":31,"text":129,"correct":22},"在实际建筑防火检查中，如遇到规范中未列举的建筑，需要根据建筑功能的具体情况，通过专家论证来确定建筑类别",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":31,"analysis":33},934472,"建筑物耐火等级共分为（ ）级，二级耐火等级楼板的耐火极限为（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":26},"四级，1.5h",{"key":24,"text":137,"correct":26},"三级，1.0h",{"key":28,"text":139,"correct":26},"四级，2.0h",{"key":31,"text":141,"correct":22},"四级，1.0h",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},934473,"一类高层民用建筑楼板耐火极限不应小于（ ）h。",[146,148,150,152],{"key":20,"text":147,"correct":26},"1.00",{"key":24,"text":149,"correct":22},"1.50",{"key":28,"text":151,"correct":26},"2.50",{"key":31,"text":153,"correct":26},"3.00",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":20,"analysis":33},934474,"一、二级耐火等级建筑的屋面板应采用不燃材料。屋面防水层宜采用不燃、难燃材料，当采用可燃防水材料且铺设在可燃、难燃保温材料上时，防水材料或可燃、难燃保温材料可采用（ ）作防护层。",[158,160,162,164],{"key":20,"text":159,"correct":22},"不燃材料",{"key":24,"text":161,"correct":26},"可燃材料",{"key":28,"text":163,"correct":26},"难燃材料",{"key":31,"text":165,"correct":26},"易燃材料",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":24,"analysis":33},934475,"下列建筑的吊顶可采用难燃材料的是（ ）。",[170,172,174,176],{"key":20,"text":171,"correct":26},"二级耐火等级建筑的门厅",{"key":24,"text":173,"correct":22},"三级耐火等级的儿童游乐厅",{"key":28,"text":175,"correct":26},"三级耐火等级建筑的门厅",{"key":31,"text":177,"correct":26},"三级耐火等级建筑的走道",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":20,"analysis":33},934476,"某建筑的一层至三层主楼与裙房为商场，层高为4.5m，四层至十七层主楼为办公，层高3.8m，地下一层为商场，地下二层部分为汽车库，其余部分为设备区。下列防火设置中，不正确的是（ ）。",[182,184,186,188],{"key":20,"text":183,"correct":22},"该建筑与周围一相同高度的办公楼通过连廊连接，防火间距为11m",{"key":24,"text":185,"correct":26},"该建筑东面设置一座10kV及以下的预装式变电站，间距为5m",{"key":28,"text":187,"correct":26},"若裙房与高层建筑主体之间设置防火墙，墙上开设甲级防火门，则裙房的防火分区与疏散楼梯可按多层建筑的要求确定",{"key":31,"text":189,"correct":26},"某会议室设置在六层，一个厅、室的疏散门不少于2个，且建筑面积不宜大于400m2",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":20,"analysis":33},934477,"某四层24m商业建筑，设置自动灭火系统和火灾自动报警系统并采用不燃或难燃装修材料，首层每个防火分区的最大允许建筑面积为（ ）。",[194,196,198,200],{"key":20,"text":195,"correct":22},"5000m2",{"key":24,"text":197,"correct":26},"4000m2",{"key":28,"text":199,"correct":26},"10000m2",{"key":31,"text":201,"correct":26},"2000m2",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":20,"analysis":33},934478,"丙类厂房地下一层某防火分区内，未设置自动灭火系统的建筑面积为200m2，其设置自动灭火系统的建筑面积不应超过（ ）m2。",[206,208,210,212],{"key":20,"text":207,"correct":22},"600",{"key":24,"text":209,"correct":26},"500",{"key":28,"text":211,"correct":26},"700",{"key":31,"text":213,"correct":26},"800",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":28,"analysis":33},934479,"对防火分区进行检查时，应检查防火分区的建筑面积。根据现行国家消防技术标准的规定，下列因素中，不影响防火分区的建筑面积划分的是（ ）。",[218,220,222,224],{"key":20,"text":219,"correct":26},"使用性质",{"key":24,"text":221,"correct":26},"耐火等级",{"key":28,"text":223,"correct":22},"防火间距",{"key":31,"text":225,"correct":26},"建筑高度",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":20,"analysis":33},934480,"某大型餐饮建筑地上6层，地下3层，每层层高均为4m。建筑高度为24m，框架结构，耐火等级一级，地下三层室内地面与室外出入口地坪的高差为12m，每层建筑面积均为4000m2。该建筑的地下一层至地上六层设有一个中庭，中庭底部投影建筑面积为200m2，中庭与周围相连通的空间进行防火分隔，采用防火隔墙时，其耐火极限不应低于（ ）h，采用防火卷帘时，其耐火极限不应低于3.0h。",[230,232,234,236],{"key":20,"text":231,"correct":22},"1.0",{"key":24,"text":233,"correct":26},"1.5",{"key":28,"text":235,"correct":26},"2.0",{"key":31,"text":237,"correct":26},"3.0",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":28,"analysis":33},934481,"一、二级耐火等级建筑内的商店营业厅、展览厅设置在单层建筑或仅设置在多层建筑的首层内时，设置自动灭火系统和火灾自动报警系统并采用不燃或难燃装修材料，其每个防火分区的最大允许建筑面积为（ ）m2。",[242,243,244,245],{"key":20,"text":195,"correct":26},{"key":24,"text":197,"correct":26},{"key":28,"text":199,"correct":22},{"key":31,"text":201,"correct":26},{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":20,"analysis":33},934482,"某建筑的一层至三层为商场，四层至十七层为办公，地下一层为商场，地下二层部分为商场，其余部分为设备区。室内装修及消防设施设备均符合相关规定。下列关于该建筑地下商场及设备区最大防火分区建筑面积，正确的是（ ）。",[250,252,254,256],{"key":20,"text":251,"correct":22},"商场营业厅2000m2，设备区2000m2",{"key":24,"text":253,"correct":26},"商场营业厅3000m2，设备区2000m2",{"key":28,"text":255,"correct":26},"商场营业厅4000m2，设备区1000m2",{"key":31,"text":257,"correct":26},"商场营业厅4000m2，设备区2000m2",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":28,"analysis":33},934483,"高层民用建筑内的地下商业营业厅若设有自动报警与灭火系统，并用不燃或难燃材料装修，其一个防火分区的最大允许建筑面积为（ ）m2。",[262,263,265,267],{"key":20,"text":209,"correct":26},{"key":24,"text":264,"correct":26},"1000",{"key":28,"text":266,"correct":22},"2000",{"key":31,"text":268,"correct":26},"4000",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":31,"analysis":33},934484,"对民用建筑的附属用房进行防火检查，下列检查结果中，不符合现行国家消防技术标准的是（ ）。",[273,275,277,279],{"key":20,"text":274,"correct":26},"住宅建筑地下车库的疏散楼梯与地上部分共用楼梯间，并按规范采取分隔措施",{"key":24,"text":276,"correct":26},"将常压燃油锅炉房设置在高层建筑地下二层",{"key":28,"text":278,"correct":26},"将常压燃气锅炉布置在商业建筑的地下二层",{"key":31,"text":280,"correct":22},"将油浸变压器室设置在剧场建筑的地下二层",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":20,"analysis":33},934485,"燃气、燃油锅炉房设置在高层建筑物内，下述不符合规定的是（ ）。",[285,287,289,291],{"key":20,"text":286,"correct":22},"不应布置在人员密集场所的上一层、下一层，但采用耐火极限不低于2.00h的隔墙可贴邻布置",{"key":24,"text":288,"correct":26},"采用无门窗洞口的耐火极限不低于2.00h的隔墙和1.50h的楼板与其他部位隔开。当必须开门时，应设甲级防火门",{"key":28,"text":290,"correct":26},"应布置在首层或地下一层靠外墙部位",{"key":31,"text":292,"correct":26},"锅炉房内设置储油间时，其总储存量不应大于1m3",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":24,"analysis":33},934486,"关于建筑防火设计的说法中，错误的是（ ）。",[297,299,301,303],{"key":20,"text":298,"correct":26},"卡拉0K厅各厅室之间采用耐火极限为2.00h的防火隔墙和1.5h的不燃烧性楼板及乙级防火门分隔",{"key":24,"text":300,"correct":22},"柴油发电机房内的储油间（柴油储量为0.8m3），采用耐火极限为2.50h的防火隔墙和1.50h的不燃烧性楼板及甲级防火门与其他部位分隔",{"key":28,"text":302,"correct":26},"高层住宅建筑下部设置的商业服务网点，采用耐火极限为2.50h且无门、窗、洞口的防火隔墙和1.50h的不燃烧性楼板与其他部位分隔",{"key":31,"text":304,"correct":26},"医院病房楼内相邻护理单元之间采用耐火极限为2.00h的防火隔墙和乙级防火门分隔",{"id":306,"libraryId":5,"type":15,"typeLabel":16,"stem":307,"options":308,"answer":20,"analysis":33},934487,"某民用建筑，地上16层，地下2层，层高均为4.5m，每层建筑面积为3000m3，一至三层为商场，四至十六层为酒店。地下一层设置设备用房、酒店后勤管理办公用房及汽车库，地下二层设置设备用房及汽车库。根据《建筑设计防火规范》GB50016-2014，以下平面布置不正确的是（ ）。",[309,311,313,315],{"key":20,"text":310,"correct":22},"常负压燃油锅炉房、干式变配电房设置在地下一层",{"key":24,"text":312,"correct":26},"空调机房、消防水池及水泵房、柴油发电机房设置在地下二层",{"key":28,"text":314,"correct":26},"锅炉房、空调机房、消防水泵房、柴油发电机房应设置自动喷水灭火系统",{"key":31,"text":316,"correct":26},"若地下二层设备房建筑面积不大于2000m2，则设备用房可划分为一个防火分区",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":31,"analysis":33},934488,"经营、存放和使用甲、乙类物品的商店、作坊和储藏间，（ ）设置在民用建筑内。",[321,323,325,327],{"key":20,"text":322,"correct":26},"总量小于1m3可以",{"key":24,"text":324,"correct":26},"不宜",{"key":28,"text":326,"correct":26},"不应",{"key":31,"text":328,"correct":22},"严禁",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":28,"analysis":33},934489,"关于将幼儿生活用房设在地下室或半地下室的做法，规范规定是（ ）。",[333,335,336,337],{"key":20,"text":334,"correct":26},"可以",{"key":24,"text":324,"correct":26},{"key":28,"text":326,"correct":22},{"key":31,"text":328,"correct":26},{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":28,"analysis":33},934490,"老年人建筑及托儿所、幼儿园的儿童用房、儿童游乐厅等儿童活动场所宜设置在独立的建筑内。当必须设置在其它高层民用建筑内时（ ）。",[342,344,346,348],{"key":20,"text":343,"correct":26},"可不设置独立的安全出口",{"key":24,"text":345,"correct":26},"宜设置独立的安全出口",{"key":28,"text":347,"correct":22},"应设置独立的安全出口",{"key":31,"text":349,"correct":26},"应设置直通楼梯的出口",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":20,"analysis":33},934491,"某医院高层病房楼地上9层，地下1层，建筑高度为43.50m，框架剪力墙结构，采用玻璃幕墙作为外围护墙体，耐火等级一级，共设有290床病床，首层至地上九层设有一个中庭。医院和疗养院的病房楼内相邻护理单元之间应采用耐火极限不低于2.00h的防火隔墙分隔，隔墙上的门应采用（ ）防火门，设置在走道上的防火门应采用常开防火门。",[354,356,358,360],{"key":20,"text":355,"correct":22},"乙级",{"key":24,"text":357,"correct":26},"甲级",{"key":28,"text":359,"correct":26},"丙级",{"key":31,"text":361,"correct":26},"常闭",{"id":363,"libraryId":5,"type":15,"typeLabel":16,"stem":364,"options":365,"answer":20,"analysis":33},934492,"高层建筑中的多功能厅设在三层以上时应符合的规定，以下不正确的是（ ）。",[366,368,370,372],{"key":20,"text":367,"correct":22},"一个厅室的使用面积不宜超过500m2",{"key":24,"text":369,"correct":26},"一个厅、室的疏散门不应少于两个",{"key":28,"text":371,"correct":26},"应设置自动报警系统",{"key":31,"text":373,"correct":26},"应设置自动灭火系统",{"id":375,"libraryId":5,"type":15,"typeLabel":16,"stem":376,"options":377,"answer":31,"analysis":33},934493,"当歌舞娱乐游艺放映场所必须设置在建筑的地上一、二、三层以外的其他楼层时，以下描述不正确的是（ ）。",[378,380,382,384],{"key":20,"text":379,"correct":26},"不应设置在地下二层及以下层：当设置在地下一层时，地下一层地面与室外出入口地坪的高差不应大于10m",{"key":24,"text":381,"correct":26},"一个厅、室的建筑面积不应大于200m2",{"key":28,"text":383,"correct":26},"一个厅、室的疏散门不少于2个，但建筑面积不大于50m2且经常停留人数不超过15人的厅、室可设置1个疏散门",{"key":31,"text":385,"correct":22},"厅、室之间及与建筑的其他部位之间，应采取耐火极限不低于2.5h的防火隔墙和不低于1.0h的不燃性楼板分隔，设置在厅、室墙上的门和该场所内其他部位相通的门均应采用乙级防火门",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":20,"analysis":33},934494,"某地上10层、地下3层的建筑，每层建筑面积为1200m2，首层为大堂，二层至五层为商店.地上六层以上各层为办公区，地下一层层高5m，设置设备用房和夜总会。下列关于该夜总会的设置及消防设计的说法中，正确的有（ ）。",[390,392,394,396],{"key":20,"text":391,"correct":22},"豪华包间的建筑面积为200m2",{"key":24,"text":393,"correct":26},"每个房间采用耐火极限为1.00h的防火隔墙与其他房间分隔",{"key":28,"text":395,"correct":26},"夜总会所在空间采用耐火极限为1.50h的防火隔墙和1.00h的楼板与其他场所分隔",{"key":31,"text":397,"correct":26},"夜总会也可设置在地下二层，但需采用防火墙与其他区域分隔",{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":24,"analysis":33},934495,"设置剪刀楼梯是当相邻两个安全出口的间距难以满足不应小于5m时的变通措施，对底部楼层为商场和步行购物街、上部为塔楼的建筑进行防火检查时，检查人员应注意核对设置剪刀楼梯的合理性，任一门户或疏散门至最近疏散楼梯间入口的距离不应大于（ ）米。",[402,404,406,408],{"key":20,"text":403,"correct":26},"5",{"key":24,"text":405,"correct":22},"10",{"key":28,"text":407,"correct":26},"7",{"key":31,"text":409,"correct":26},"12",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":24,"analysis":33},934496,"设置不少于2部疏散楼梯的一、二级耐火等级多层公共建筑，如顶层局部升高，当高出部分的层数不超过2层、人数之和不超过50人且每层建筑面积不大于（ ）m2时，高出部分可设置1部疏散楼梯，但至少应另外设置1个直通建筑主体上人平屋面的安全出口，且上人屋面应符合人员安全疏散的要求。",[414,415,416,417],{"key":20,"text":53,"correct":26},{"key":24,"text":55,"correct":22},{"key":28,"text":43,"correct":26},{"key":31,"text":41,"correct":26},{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":20,"analysis":33},934497,"某一类高层综合楼设有裙房；裙房地上5层，使用功能为办公楼；裙房与高层建筑主体之间设置防火墙。则该高层主体的疏散楼梯可采用（ ）。",[422,423,424,426],{"key":20,"text":75,"correct":22},{"key":24,"text":79,"correct":26},{"key":28,"text":425,"correct":26},"设机械加压送风系统的封闭楼梯间",{"key":31,"text":81,"correct":26},{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":24,"analysis":33},934498,"歌舞娱乐游艺放映场所当必须设置在建筑地下或半地下室时，除面积满足一定条件外，其经常停留人数不超过（ ）时可设置一个疏散门。",[431,433,435,437],{"key":20,"text":432,"correct":26},"10人",{"key":24,"text":434,"correct":22},"15人",{"key":28,"text":436,"correct":26},"20人",{"key":31,"text":438,"correct":26},"30人",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":31,"analysis":33},934499,"一座容纳人数为10000人的体育馆，疏散门数量至少为（ ）个。",[443,445,447,449],{"key":20,"text":444,"correct":26},"34",{"key":24,"text":446,"correct":26},"25",{"key":28,"text":448,"correct":26},"19",{"key":31,"text":450,"correct":22},"15",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":20,"analysis":33},934500,"某已建办公楼的建筑高度为66m，一级耐火等级，己按现行有关国家工程建设消防技术标准设置了消防设施。该建筑内疏散门数量不少于2个的开敞式办公区，其室内任一点至最近疏散门的直线距离不应大于（ ）m。",[455,457,459,460],{"key":20,"text":456,"correct":22},"37.5",{"key":24,"text":458,"correct":26},"30",{"key":28,"text":446,"correct":26},{"key":31,"text":461,"correct":26},"20",{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":20,"analysis":33},934501,"耐火等级为一级的多层教学建筑位于两封闭楼梯之间的房间安全疏散距离为（ ）m；若设自动喷淋灭火系统其安全疏散距离可增加到（ ）。",[466,468,470,472],{"key":20,"text":467,"correct":22},"35，43",{"key":24,"text":469,"correct":26},"40，50",{"key":28,"text":471,"correct":26},"40，46",{"key":31,"text":473,"correct":26},"35，45",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":28,"analysis":33},934502,"高层建筑内的观众厅、展览厅、多功能厅、餐厅、营业厅和阅览室等，其室内任何一点至最近的疏散出口的直线距离，不宜超过（ ）。",[478,480,482,484],{"key":20,"text":479,"correct":26},"21m",{"key":24,"text":481,"correct":26},"25m",{"key":28,"text":483,"correct":22},"30m",{"key":31,"text":485,"correct":26},"35m",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":24,"analysis":33},934503,"办公建筑的开放式、半开放式办公楼，其室内任何一点至最近安全出口的直线距离应（ ）",[490,492,494,496],{"key":20,"text":491,"correct":26},"≤40m",{"key":24,"text":493,"correct":22},"≤30m",{"key":28,"text":495,"correct":26},"≤25m",{"key":31,"text":497,"correct":26},"≤20m",{"id":499,"libraryId":5,"type":15,"typeLabel":16,"stem":500,"options":501,"answer":28,"analysis":33},934504,"第一个避难层（间）的楼地面至灭火救援场地地面的高度不应大于（ ）m，两个避难层（间）之间的高度不宜大于（ ）m。",[502,504,506,508],{"key":20,"text":503,"correct":26},"45，45",{"key":24,"text":505,"correct":26},"45，50",{"key":28,"text":507,"correct":22},"50，50",{"key":31,"text":509,"correct":26},"50，45",{"id":511,"libraryId":5,"type":15,"typeLabel":16,"stem":512,"options":513,"answer":28,"analysis":33},934505,"某超高层办公建筑，建筑总高度为180m，共设置3个避难层，投入使用前对避难层进行检查，下列检查结果中，正确的是（ ）。",[514,516,518,520],{"key":20,"text":515,"correct":26},"设置了独立的机械排烟设施",{"key":24,"text":517,"correct":26},"第一个避难层的楼地面与灭火救援场地地面的高差为55m",{"key":28,"text":519,"correct":22},"通向避难层的疏散楼梯在避难层进行了分隔",{"key":31,"text":521,"correct":26},"避难层兼作设备层，避难区域与设备管道采用耐火极限1.0h的防火隔墙分隔",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":20,"analysis":33},934506,"高层病房楼应在二层及以上的病房楼层和洁净手术部设置避难间。下列设置不正确的是（ ）。",[526,528,530,532],{"key":20,"text":527,"correct":22},"避难间服务的护理单元不应超过2个，其净面积应按每个避难间不小于25.0m2确定",{"key":24,"text":529,"correct":26},"应靠近楼梯间，并应采用耐火极限不低于2.00h的防火隔墙和甲级防火门与其他部位分隔",{"key":28,"text":531,"correct":26},"应设置消防专线电话和消防应急广播",{"key":31,"text":533,"correct":26},"应设置直接对外的可开启窗口或独立的机械防烟设施，外窗应采用乙级防火窗",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":24,"analysis":33},934507,"跃廊式住宅的安全疏散距离，应按如下规则中的（ ）计算。Ⅰ、应从户门算起；Ⅱ、应从小楼梯算起；Ⅲ、小楼梯的一段距离按1倍水平投影计算；Ⅳ、小楼梯的一段距离按1.5倍水平投影计算",[538,540,542,544],{"key":20,"text":539,"correct":26},"Ⅰ、Ⅲ",{"key":24,"text":541,"correct":22},"Ⅰ、Ⅳ",{"key":28,"text":543,"correct":26},"Ⅱ、Ⅲ",{"key":31,"text":545,"correct":26},"Ⅱ、Ⅳ",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":24,"analysis":33},934508,"耐火等级为三级的办公楼，其最多允许层数为（ ）。",[550,552,554,556],{"key":20,"text":551,"correct":26},"4层",{"key":24,"text":553,"correct":22},"5层",{"key":28,"text":555,"correct":26},"6层",{"key":31,"text":557,"correct":26},"7层",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":31,"analysis":33},934509,"如受条件限制，必须将油浸电力变压器室布置在民用建筑主体建筑内时，下列防火措施（ ）是错误的。",[562,564,566,568],{"key":20,"text":563,"correct":26},"不应布置在人员密集场所的上一层、下一层或贴临",{"key":24,"text":565,"correct":26},"疏散门应直通室外或安全出口",{"key":28,"text":567,"correct":26},"与其他部位之间应采用耐火极限不低于2.00h的防火隔墙和1.50h的不燃性楼板分隔",{"key":31,"text":569,"correct":22},"储油间应采用耐火极限不低于2.00h的防火隔墙与锅炉间分隔",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":28,"analysis":33},934510,"根据《建筑设计防火规范》，防火墙横截面中心线距天窗端面的水平距离小于（ ）且天窗端面为可燃性时，应采取防止火势蔓延的措施。",[574,575,577,578],{"key":20,"text":403,"correct":26},{"key":24,"text":576,"correct":26},"6",{"key":28,"text":32,"correct":22},{"key":31,"text":25,"correct":26},{"id":580,"libraryId":5,"type":15,"typeLabel":16,"stem":581,"options":582,"answer":24,"analysis":33},934511,"按《建筑设计防火规范》GB50016-2014对防火墙的要求，以下错误的是（ ）。",[583,585,587,589],{"key":20,"text":584,"correct":26},"应直接设置在基础上或钢筋混凝土框架上",{"key":24,"text":586,"correct":22},"民用建筑如必须在防火墙内设排气道时，其两侧的墙身厚度均不应小于12cm",{"key":28,"text":588,"correct":26},"防火墙必须开门窗洞时，应设置不可开启或火灾时能自动关闭的甲级防火门、窗",{"key":31,"text":590,"correct":26},"如设在转角附近，内转角两侧墙上的门窗洞口之间最近边缘的水平距离不应小于4m",{"id":592,"libraryId":5,"type":15,"typeLabel":16,"stem":593,"options":594,"answer":31,"analysis":33},934512,"根据《建筑设计防火规范》，医院中的洁净手术室或洁净手术部、附设在建筑中的歌舞娱乐放映游艺场所以及附设在居住建筑中的托儿所、幼儿园的儿童用房和儿童游乐厅等儿童活动场所、老年人建筑，应采用耐火极限不低于（ ）h的不燃性墙和耐火极限不低于1.00h的楼板与其它场所或部位隔开，当墙上必须开门时应设置乙级防火门。",[595,596,597,599],{"key":20,"text":147,"correct":26},{"key":24,"text":153,"correct":26},{"key":28,"text":598,"correct":26},"4.00",{"key":31,"text":600,"correct":22},"2.00",[602,605,608,611,614,617],{"id":15,"name":603,"category":7,"favorite":604},"领导干部任职前廉政法规知识测试题",92,{"id":606,"name":607,"category":7,"favorite":15},595,"建筑结构与设备",{"id":609,"name":610,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":612,"name":613,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":615,"name":616,"category":7,"favorite":8},534,"BIM工程师",{"id":618,"name":616,"category":7,"favorite":8},535]