[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-53":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":717},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,53,50,2960,[13,34,42,54,66,78,86,98,110,128,143,158,172,187,202,216,230,244,259,274,289,303,317,331,346,360,374,388,403,418,433,447,461,475,490,504,518,532,546,561,575,589,604,618,633,647,660,674,689,703],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},934311,1,"单选题","热通过直接接触的物体从温度较高部位传递到温度较低部位的现象，称为（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","热传导",true,{"key":24,"text":25,"correct":26},"B","热对流",false,{"key":28,"text":29,"correct":26},"C","热辐射",{"key":31,"text":32,"correct":26},"D","热传播","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},934312,"以电磁波形式传递热量的现象，称为（ ）。",[38,39,40,41],{"key":20,"text":21,"correct":26},{"key":24,"text":29,"correct":22},{"key":28,"text":25,"correct":26},{"key":31,"text":32,"correct":26},{"id":43,"libraryId":5,"type":15,"typeLabel":16,"stem":44,"options":45,"answer":24,"analysis":33},934313,"由于雷击引燃了汽油储罐导致火灾，根据《火灾分类》（GB\u002FT4968-2008），此次火灾属于（ ）。",[46,48,50,52],{"key":20,"text":47,"correct":26},"A类火灾",{"key":24,"text":49,"correct":22},"B类火灾",{"key":28,"text":51,"correct":26},"C类火灾",{"key":31,"text":53,"correct":26},"D类火灾",{"id":55,"libraryId":5,"type":15,"typeLabel":16,"stem":56,"options":57,"answer":20,"analysis":33},934314,"2004年12月21日，湖南省常德市鼎城区桥南市场发生火灾，大火蔓延，烧毁3220个门面、3029个摊位、30个仓库，过火建筑面积83276m2，造成了5人死亡14人重伤，直接财产损失1.876亿元，受灾5200余户，整个市场烧毁殆尽。一些精密仪器、棉纺织物等还因受火灾烟气的侵蚀造成永久性破坏。按照火灾事故所造成的灾害损失程度分类，这是（ ）。",[58,60,62,64],{"key":20,"text":59,"correct":22},"特别重大火灾",{"key":24,"text":61,"correct":26},"重大火灾",{"key":28,"text":63,"correct":26},"较大火灾",{"key":31,"text":65,"correct":26},"一般火灾",{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":24,"analysis":33},934315,"下列关于建筑火灾蔓延传热基础的叙述中，错误的是（ ）。",[70,72,74,76],{"key":20,"text":71,"correct":26},"导热率大的材料利于火势蔓延",{"key":24,"text":73,"correct":22},"工程上常把具有相对位移的流体与所接触的固体表面之间的热传递过程称为热传导",{"key":28,"text":75,"correct":26},"热辐射不需要通过接触即可进行",{"key":31,"text":77,"correct":26},"热对流中，热量传递与流体流动关系密切",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":24,"analysis":33},934316,"造成3人死亡，9人重伤，直接经济损失5100万元，按照事故造成的损失程度分类，该事故可以定性为（ ）。",[82,83,84,85],{"key":20,"text":59,"correct":26},{"key":24,"text":61,"correct":22},{"key":28,"text":63,"correct":26},{"key":31,"text":65,"correct":26},{"id":87,"libraryId":5,"type":15,"typeLabel":16,"stem":88,"options":89,"answer":24,"analysis":33},934317,"以下常见原因中，发生火灾概率最高的是（ ）。",[90,92,94,96],{"key":20,"text":91,"correct":26},"吸烟",{"key":24,"text":93,"correct":22},"生活用火不慎",{"key":28,"text":95,"correct":26},"玩火",{"key":31,"text":97,"correct":26},"生产作业不慎",{"id":99,"libraryId":5,"type":15,"typeLabel":16,"stem":100,"options":101,"answer":28,"analysis":33},934318,"在防火的基本方法中，静电消除设备、接地避雷、设置火星熄灭装置等方法属于（ ）。",[102,104,106,108],{"key":20,"text":103,"correct":26},"控制可燃物",{"key":24,"text":105,"correct":26},"隔绝助燃物",{"key":28,"text":107,"correct":22},"控制引火源",{"key":31,"text":109,"correct":26},"阻止化学抑制",{"id":111,"libraryId":5,"type":112,"typeLabel":113,"stem":114,"options":115,"answer":127,"analysis":33},934319,2,"多选题","下列符合重大火灾标准的是（ ）。",[116,118,120,122,124],{"key":20,"text":117,"correct":22},"15人死亡",{"key":24,"text":119,"correct":22},"60人重伤",{"key":28,"text":121,"correct":26},"1000万元财产损失",{"key":31,"text":123,"correct":22},"直接经济损失7000万元",{"key":125,"text":126,"correct":26},"E","直接经济损失1亿元","ABD",{"id":129,"libraryId":5,"type":112,"typeLabel":113,"stem":130,"options":131,"answer":142,"analysis":33},934320,"烟气扩散流动速度与烟气温度和流动方向有关。下列关于烟气流动的驱动力的说法中正确的是（ ）。",[132,134,136,138,140],{"key":20,"text":133,"correct":22},"烟气流动的驱动力包括室内外温差引起的烟囱效应、外界风和火风压的影响",{"key":24,"text":135,"correct":22},"烟囱效应是发生在建筑竖井内，室内空气温度高于室外，引发浮力作用引起的空气向上运动的现象",{"key":28,"text":137,"correct":22},"在火灾过程中，烟囱效应是造成烟气向上蔓延的主要因素",{"key":31,"text":139,"correct":26},"火灾时，室内气流总的方向是自上而下，着火层的位置越高，影响的层数越多",{"key":125,"text":141,"correct":22},"如果火风压大于房间外墙窗口的压力，则大量的烟气将通过外墙窗口向室外蔓延","ABCE",{"id":144,"libraryId":5,"type":112,"typeLabel":113,"stem":145,"options":146,"answer":157,"analysis":33},934321,"水是一种经济的灭火方式，下列关于水灭火的灭火机理说法正确的是（ ）。",[147,149,151,153,155],{"key":20,"text":148,"correct":22},"用水扑灭一般固体物质引起的火灾，主要通过冷却作用来实现",{"key":24,"text":150,"correct":22},"水具有较大的比热容和很高的汽化热，冷却性能很好",{"key":28,"text":152,"correct":22},"水雾的水滴直径细小，比表面积大，和空气接触范围大，极易吸收热气流的热量",{"key":31,"text":154,"correct":22},"水雾能很快地降低温度，效果比水灭火更为明显",{"key":125,"text":156,"correct":26},"水、水喷雾、细水雾灭火均具有冷却、窒息的灭火机理","ABCD",{"id":159,"libraryId":5,"type":112,"typeLabel":113,"stem":160,"options":161,"answer":157,"analysis":33},934322,"建筑物的安全疏散设施有（ ）。",[162,164,166,168,170],{"key":20,"text":163,"correct":22},"疏散楼梯",{"key":24,"text":165,"correct":22},"疏散走道",{"key":28,"text":167,"correct":22},"安全出口",{"key":31,"text":169,"correct":22},"应急广播",{"key":125,"text":171,"correct":26},"防盗门",{"id":173,"libraryId":5,"type":112,"typeLabel":113,"stem":174,"options":175,"answer":186,"analysis":33},934323,"《建筑设计防火规范》GB50016-2014不适用于（ ）。",[176,178,180,182,184],{"key":20,"text":177,"correct":22},"炸药厂",{"key":24,"text":179,"correct":22},"花炮厂",{"key":28,"text":181,"correct":26},"炼钢厂",{"key":31,"text":183,"correct":26},"炼油厂",{"key":125,"text":185,"correct":26},"木材厂","AB",{"id":188,"libraryId":5,"type":112,"typeLabel":113,"stem":189,"options":190,"answer":201,"analysis":33},934324,"甲类生产的火灾危险性类别的火灾危险性特征包括（ ）。",[191,193,195,197,199],{"key":20,"text":192,"correct":26},"闪点≤28℃的液体",{"key":24,"text":194,"correct":22},"爆炸下限＜10%的气体",{"key":28,"text":196,"correct":22},"常温下能自行分解或在空气中氧化即能导致迅速自燃或爆炸的物质",{"key":31,"text":198,"correct":22},"常温下受到水或空气中水蒸气的作用，能产生可燃气体并引起燃烧或爆炸的物质",{"key":125,"text":200,"correct":26},"在密闭设备内操作温度小于物质本身自燃点的生产","BCD",{"id":203,"libraryId":5,"type":112,"typeLabel":113,"stem":204,"options":205,"answer":186,"analysis":33},934325,"以下常温下使用或加工不燃烧物质的生产场所是（ ）。",[206,208,210,212,214],{"key":20,"text":207,"correct":22},"消防水泵房",{"key":24,"text":209,"correct":22},"地下污水处理站",{"key":28,"text":211,"correct":26},"镁合金冷加工车间",{"key":31,"text":213,"correct":26},"化肥焙烧炉",{"key":125,"text":215,"correct":26},"造纸厂",{"id":217,"libraryId":5,"type":112,"typeLabel":113,"stem":218,"options":219,"answer":157,"analysis":33},934326,"下列使用或产生爆炸下限＜10%的气体的场所包括（ ）。",[220,222,224,226,228],{"key":20,"text":221,"correct":22},"液化石油气灌瓶间",{"key":24,"text":223,"correct":22},"乙炔站",{"key":28,"text":225,"correct":22},"氢气",{"key":31,"text":227,"correct":22},"电解水或电解食盐厂房",{"key":125,"text":229,"correct":26},"氨压缩机房",{"id":231,"libraryId":5,"type":112,"typeLabel":113,"stem":232,"options":233,"answer":142,"analysis":33},934327,"下列使用或产生闪点＜28℃的液体的场所包括（ ）。",[234,236,238,240,242],{"key":20,"text":235,"correct":22},"橡胶制品的涂胶和胶浆部位",{"key":24,"text":237,"correct":22},"二硫化碳的粗馏、精馏工段及其应用部位",{"key":28,"text":239,"correct":22},"农药乐果厂房、敌敌畏的合成厂房",{"key":31,"text":241,"correct":26},"植物油加工厂的精炼部位",{"key":125,"text":243,"correct":22},"酒精度为60度的白酒勾兑车间、灌装车间、酒泵房",{"id":245,"libraryId":5,"type":112,"typeLabel":113,"stem":246,"options":247,"answer":258,"analysis":33},934328,"下列储存物品的火灾危险性属于甲类的是（ ）。",[248,250,252,254,256],{"key":20,"text":249,"correct":22},"闪点为20℃的液体",{"key":24,"text":251,"correct":26},"爆炸下限为12%的气体",{"key":28,"text":253,"correct":26},"可燃固体",{"key":31,"text":255,"correct":26},"常温下与空气接触能缓慢氧化，积热不散引起自燃的物品",{"key":125,"text":257,"correct":22},"常温下遇水产生可燃气体并引起燃烧或爆炸的物质","AE",{"id":260,"libraryId":5,"type":112,"typeLabel":113,"stem":261,"options":262,"answer":273,"analysis":33},934329,"商业服务网点可经营的功能有哪些（ ）。",[263,265,267,269,271],{"key":20,"text":264,"correct":26},"经营甲类物品的商店",{"key":24,"text":266,"correct":22},"副食店",{"key":28,"text":268,"correct":22},"邮政所",{"key":31,"text":270,"correct":22},"理发店",{"key":125,"text":272,"correct":22},"粮店","BCDE",{"id":275,"libraryId":5,"type":112,"typeLabel":113,"stem":276,"options":277,"answer":288,"analysis":33},934330,"安全疏散距离是安全疏散设计的一项重要内容，关于安全疏散距离的设置，下列说法中，符合现行国家消防技术标准要求的有（ ）。（2016-能力）",[278,280,282,284,286],{"key":20,"text":279,"correct":22},"商场营业厅内任一点至疏散门的距离不应大于30m",{"key":24,"text":281,"correct":22},"设置自动喷水灭火系统的场所，室内任一点至安全出口的安全疏散距离可在规范规定值的基础上增加25%",{"key":28,"text":283,"correct":26},"高层建筑在首层未采用防烟楼梯间前室时，可将直通室外的门设置在离楼梯间不大于15m处",{"key":31,"text":285,"correct":22},"采用敞开式外廊的建筑，安全疏散距离可以在规范规定值的基础上增加5m",{"key":125,"text":287,"correct":22},"位于二级耐火等级建筑内的卡拉0K厅，厅内任一点至直通疏散走道的疏散门的直线距离不应大于9m","ABDE",{"id":290,"libraryId":5,"type":112,"typeLabel":113,"stem":291,"options":292,"answer":142,"analysis":33},934331,"除剧场、电影院、礼堂、体育馆外的其他公共建筑，其房间疏散门、安全出口、疏散走道和疏散楼梯的各自总净宽度，应符合下列规定（ ）。",[293,295,297,299,301],{"key":20,"text":294,"correct":22},"当每层疏散人数不等时，疏散楼梯的总净宽度可分层计算，地上建筑内下层楼梯的总净宽度应按该层及以上疏散人数最多一层的人数计算",{"key":24,"text":296,"correct":22},"地下建筑内上层楼梯的总净宽度应按该层及以下疏散人数最多一层的人数计算",{"key":28,"text":298,"correct":22},"首层外门的总净宽度应按该建筑疏散人数最多一层的人数计算确定，不供其他楼层人员疏散的外门，可按本层的疏散人数计算确定",{"key":31,"text":300,"correct":26},"地下或半地下人员密集的厅、室和歌舞娱乐放映游艺场所，其房间疏散门、安全出口、疏散走道和疏散楼梯的各自总净宽度，应根据疏散人数按每100人不小于0.75m计算确定",{"key":125,"text":302,"correct":22},"高层建筑的房间疏散门、安全出口、疏散走道和疏散楼梯的各自总净宽度，应根据疏散人数按每100人不小于1.00m计算确定",{"id":304,"libraryId":5,"type":112,"typeLabel":113,"stem":305,"options":306,"answer":273,"analysis":33},934332,"对于建筑高度的检查，下列说法正确的是（ ）。",[307,309,311,313,315],{"key":20,"text":308,"correct":26},"同一座建筑有多种形式的屋面时，建筑高度分别计算后，取其中的最小值",{"key":24,"text":310,"correct":22},"楼梯出口小间等辅助用房占屋面面积不大于1\u002F4时，不需计入建筑高度",{"key":28,"text":312,"correct":22},"建筑屋面为坡屋面时，建筑高度为建筑室外设计地面至檐口与屋脊的平均高度",{"key":31,"text":314,"correct":22},"建筑屋面为平屋面时，建筑高度为建筑室外设计地面至屋面面层的高度",{"key":125,"text":316,"correct":22},"对于住宅建筑，设置在底部且室内高度不大于2.2m的自行车库不计入建筑高度",{"id":318,"libraryId":5,"type":112,"typeLabel":113,"stem":319,"options":320,"answer":330,"analysis":33},934333,"以下（ ）生产的火灾危险性类别属于丙类。",[321,323,324,326,328],{"key":20,"text":322,"correct":26},"甲醇合成厂房",{"key":24,"text":223,"correct":26},{"key":28,"text":325,"correct":26},"煤油灌装间",{"key":31,"text":327,"correct":22},"沥青加工厂房",{"key":125,"text":329,"correct":22},"印刷厂房","DE",{"id":332,"libraryId":5,"type":112,"typeLabel":113,"stem":333,"options":334,"answer":345,"analysis":33},934334,"下列关于生产火灾危险性分类的叙述中，正确的有（ ）。",[335,337,339,341,343],{"key":20,"text":336,"correct":22},"闪点为28℃的液体的厂房火灾危险性为乙类，闪点为60℃的液体为丙类",{"key":24,"text":338,"correct":22},"爆炸下限为10%的气体的厂房火灾危险性为乙类",{"key":28,"text":340,"correct":26},"易燃固体的厂房火灾危险性都为甲类",{"key":31,"text":342,"correct":26},"可燃固体以及使用可燃固体进行的生产作业，其火灾危险性都为丙类",{"key":125,"text":344,"correct":22},"强氧化剂火灾危险性要么为甲类，要么为乙类","ABE",{"id":347,"libraryId":5,"type":112,"typeLabel":113,"stem":348,"options":349,"answer":359,"analysis":33},934335,"下列厂房中属于甲类火灾危险性的有（ ）。",[350,352,354,356,358],{"key":20,"text":351,"correct":22},"甲醇生产厂房",{"key":24,"text":353,"correct":26},"松节油生产厂房",{"key":28,"text":355,"correct":22},"植物油浸出厂房",{"key":31,"text":357,"correct":26},"甘油制备厂房",{"key":125,"text":327,"correct":26},"AC",{"id":361,"libraryId":5,"type":112,"typeLabel":113,"stem":362,"options":363,"answer":157,"analysis":33},934337,"以下（ ）的火灾危险性类别属于甲类。",[364,366,368,370,372],{"key":20,"text":365,"correct":22},"白酒液态法酿酒车间",{"key":24,"text":367,"correct":22},"酒精蒸馏塔",{"key":28,"text":369,"correct":22},"白兰地蒸馏车间",{"key":31,"text":371,"correct":22},"酒精度为40度的勾兑车间",{"key":125,"text":373,"correct":26},"酒精度为37度的灌装车间",{"id":375,"libraryId":5,"type":112,"typeLabel":113,"stem":376,"options":377,"answer":157,"analysis":33},934338,"同一座厂房或厂房的任一防火分区内有不同火灾危险性生产时，厂房或防火分区内的生产火灾危险性类别应按火灾危险性较大的部分确定。丁、戊类厂房内的油漆工段，当同时满足（ ）条件时，可按火灾危险性较小的部分确定。",[378,380,382,384,386],{"key":20,"text":379,"correct":22},"采用封闭喷漆工艺",{"key":24,"text":381,"correct":22},"封闭喷漆空间内保持负压",{"key":28,"text":383,"correct":22},"油漆工段设置可燃气体探测报警系统或自动抑爆系统",{"key":31,"text":385,"correct":22},"且油漆工段占所在防火分区建筑面积的比例不大于20%",{"key":125,"text":387,"correct":26},"油漆工段设置自动灭火系统",{"id":389,"libraryId":5,"type":112,"typeLabel":113,"stem":390,"options":391,"answer":402,"analysis":33},934339,"下列关于确定厂房火灾危险性分类的叙述中，错误的有哪些（ ）。",[392,394,396,398,400],{"key":20,"text":393,"correct":22},"同一座厂房或厂房的任一防火分区内有不同火灾危险性生产时，厂房或防火分区内的生产火灾危险性类别应按面积较大的部分确定",{"key":24,"text":395,"correct":26},"当生产过程中使用或产生易燃、可燃物的量较少，不足以构成爆炸或火灾危险时，可按实际情况确定",{"key":28,"text":397,"correct":26},"火灾危险性较大的生产部分占本层或本防火分区面积的比例小于5%，且发生火灾事故时不足以蔓延到其他部位时，可按火灾危险性较小的部分确定",{"key":31,"text":399,"correct":22},"丁、戊类厂房内的油漆工段小于15%，且发生火灾事故时不足以蔓延到其他部位时，可按火灾危险性较小的部分确定",{"key":125,"text":401,"correct":22},"火灾危险性较大的生产部分占本层或本防火分区面积的比例小于10%，且火灾危险性较大的生产部分采取了有效的防火措施，可按火灾危险性较小的部分确定","ADE",{"id":404,"libraryId":5,"type":112,"typeLabel":113,"stem":405,"options":406,"answer":417,"analysis":33},934340,"下列关于储存物品火灾危险性的叙述中，错误的是（ ）。",[407,409,411,413,415],{"key":20,"text":408,"correct":26},"同一座仓库或仓库的任一防火分区内储存不同火灾危险性物品时，仓库或防火分区的火灾危险性应按火灾危险性最大的物品确定",{"key":24,"text":410,"correct":26},"丁、戊类储存物品仓库的火灾危险性，当可燃包装重量大于物品本身重量1\u002F4时，应按丙类确定",{"key":28,"text":412,"correct":22},"丁、戊类储存物品仓库的火灾危险性，当可燃包装体积大于物品本身体积的1\u002F2时，应按丁类确定",{"key":31,"text":414,"correct":22},"难燃烧固体物品储存的火灾危险性为戊类",{"key":125,"text":416,"correct":22},"助燃气体物品储存的火灾危险性丙类","CDE",{"id":419,"libraryId":5,"type":112,"typeLabel":113,"stem":420,"options":421,"answer":432,"analysis":33},934341,"下列关于建筑物耐火等级的叙述中，正确的是（ ）。",[422,424,426,428,430],{"key":20,"text":423,"correct":26},"某七层乙类厂房，耐火等级采用二级",{"key":24,"text":425,"correct":22},"某建筑高度为10m的单层丙类厂房，耐火等级采用三级",{"key":28,"text":427,"correct":26},"某建筑高度为10m的三层丙类厂房，耐火等级采用三级",{"key":31,"text":429,"correct":22},"某建筑高度为10m的单层戊类厂房，耐火等级采用四级",{"key":125,"text":431,"correct":22},"耐火等级为一级的戊类厂房，其建筑层数不限","BDE",{"id":434,"libraryId":5,"type":112,"typeLabel":113,"stem":435,"options":436,"answer":142,"analysis":33},934342,"下列关于工业建筑层数设置的叙述中，哪些是正确的（ ）。",[437,439,441,443,445],{"key":20,"text":438,"correct":22},"所有甲类厂房都宜单层",{"key":24,"text":440,"correct":22},"耐火等级为一级的乙类厂房、一二级丙类厂房以及一二级丁戊类厂房最多允许的层数不限",{"key":28,"text":442,"correct":22},"乙类二级厂房最多允许的层数为6层",{"key":31,"text":444,"correct":26},"丙、丁类三级厂房最多允许的层数为2层",{"key":125,"text":446,"correct":22},"戊类三级厂房最多允许的层数为3层",{"id":448,"libraryId":5,"type":112,"typeLabel":113,"stem":449,"options":450,"answer":273,"analysis":33},934343,"以下（ ）建筑允许层数不限。",[451,453,455,457,459],{"key":20,"text":452,"correct":26},"一级耐火等级甲类厂房",{"key":24,"text":454,"correct":22},"一级耐火等级乙类厂房",{"key":28,"text":456,"correct":22},"一、二级耐火等级丙类厂房",{"key":31,"text":458,"correct":22},"一、二级耐火等级丁类厂房",{"key":125,"text":460,"correct":22},"一、二级耐火等级戊类厂房",{"id":462,"libraryId":5,"type":112,"typeLabel":113,"stem":463,"options":464,"answer":258,"analysis":33},934344,"以下（ ）厂房可设1个安全出口。",[465,467,469,471,473],{"key":20,"text":466,"correct":22},"甲类厂房，每层面积小于100m2，且同时作业人数≤5人",{"key":24,"text":468,"correct":26},"乙类厂房，每层面积小于150m2，且同时作业人数≤15人",{"key":28,"text":470,"correct":26},"丙类厂房，每层面积小于250m2，且同时作业人数≤25人",{"key":31,"text":472,"correct":26},"丁类厂房，每层面积小于500m2，且同时作业人数≤30人",{"key":125,"text":474,"correct":22},"地下丙类厂房，每层面积小于50m2，且同时作业人数≤15人",{"id":476,"libraryId":5,"type":112,"typeLabel":113,"stem":477,"options":478,"answer":489,"analysis":33},934345,"设置在建筑物内的柴油发电机，其进入建筑物内的燃料供给管道应符合（ ）规定。",[479,481,483,485,487],{"key":20,"text":480,"correct":22},"应在进入建筑物前设置自动和手动切断阀",{"key":24,"text":482,"correct":22},"储油间的油箱应密闭且应设置通向室外的通气管，通气管应设置带阻火器的呼吸阀，油箱的下部应设置防止油品流散的设施",{"key":28,"text":484,"correct":22},"应在设备间内设置自动和手动切断阀",{"key":31,"text":486,"correct":26},"火灾危险无法靠近，可不设置手动切断阀",{"key":125,"text":488,"correct":26},"储油间的油箱应密闭且应设置通向室内通道的通气管","ABC",{"id":491,"libraryId":5,"type":112,"typeLabel":113,"stem":492,"options":493,"answer":157,"analysis":33},934346,"下列关于商店、展览建筑平面布置的叙述中正确的是（ ）。",[494,496,498,500,502],{"key":20,"text":495,"correct":22},"采用三级耐火等级建筑时，不应超过2层",{"key":24,"text":497,"correct":22},"采用四级耐火等级建筑时，应为单层",{"key":28,"text":499,"correct":22},"设置在三级耐火等级的建筑内时，应布置在首层或二层",{"key":31,"text":501,"correct":22},"设置在四级耐火等级的建筑内时，应布置在首层",{"key":125,"text":503,"correct":26},"不应设置在地下二层及以下楼层",{"id":505,"libraryId":5,"type":112,"typeLabel":113,"stem":506,"options":507,"answer":330,"analysis":33},934347,"以下（ ）用房可以设置在地下二层。",[508,510,512,514,516],{"key":20,"text":509,"correct":26},"老年人活动场所",{"key":24,"text":511,"correct":26},"医院住院部",{"key":28,"text":513,"correct":26},"歌舞娱乐游艺放映场所",{"key":31,"text":515,"correct":22},"电影院、剧院、礼堂",{"key":125,"text":517,"correct":22},"商店、展览建筑",{"id":519,"libraryId":5,"type":112,"typeLabel":113,"stem":520,"options":521,"answer":157,"analysis":33},934348,"建筑高度大于27m、不大于54m的住宅建筑，当满足（ ）等条件时，每个单元可设1部疏散楼梯。",[522,524,526,528,530],{"key":20,"text":523,"correct":22},"每个单元任一层的建筑面积不大于650m2",{"key":24,"text":525,"correct":22},"任一户门至最近安全出口的距离不大于10m",{"key":28,"text":527,"correct":22},"每个单元的疏散楼梯应通至屋面",{"key":31,"text":529,"correct":22},"单元之间的疏散楼梯应能通过屋面连通",{"key":125,"text":531,"correct":26},"户门应采用甲级防火门",{"id":533,"libraryId":5,"type":112,"typeLabel":113,"stem":534,"options":535,"answer":330,"analysis":33},934349,"住宅建筑符合以下（ ）条件时，可设1个安全出口。",[536,538,540,542,544],{"key":20,"text":537,"correct":26},"多层建筑：每个单元任一层的建筑面积＞650m2，且任一户门至最近安全出口的距离≤15m",{"key":24,"text":539,"correct":26},"二类高层建筑：每个单元任一层的建筑面积≤650m2，且任一户门至最近安全出口的距离≤15m，且楼梯能通至屋面",{"key":28,"text":541,"correct":26},"一类高层建筑：每个单元任一层的建筑面积≤650m2，且任一户门至最近安全出口的距离≤15m",{"key":31,"text":543,"correct":22},"多层建筑：每个单元任一层的建筑面积≤650m2，且任一户门至最近安全出口的距离≤15m",{"key":125,"text":545,"correct":22},"二类高层建筑：每个单元任一层的建筑面积≤650m2，且任一户门至最近安全出口的距离≤10m，且楼梯能通至屋面，户门采用乙级防火门",{"id":547,"libraryId":5,"type":112,"typeLabel":113,"stem":548,"options":549,"answer":560,"analysis":33},934350,"当建筑的外墙外保温系统规范的规定采用燃烧性能为B1、B2级的保温材料时，除（ ）外，建筑的外墙上门、窗的耐火完整性不应低于0.50h。",[550,552,554,556,558],{"key":20,"text":551,"correct":26},"建筑高度大于27m、不大于54m且采用B1级保温材料的住宅建筑",{"key":24,"text":553,"correct":22},"建筑高度不大于27m且采用B1级保温材料的住宅建筑",{"key":28,"text":555,"correct":22},"建筑高度不大于24m且采用B1级保温材料的公共建筑",{"key":31,"text":557,"correct":26},"建筑高度不大于24m且采用B2级保温材料的公共建筑",{"key":125,"text":559,"correct":26},"建筑高度不大于27m且采用B2级保温材料的住宅建筑","BC",{"id":562,"libraryId":5,"type":112,"typeLabel":113,"stem":563,"options":564,"answer":489,"analysis":33},934351,"高层民用建筑应设环形消防车道。对于（ ），可沿建筑的一个长边设置消防车道，但该长边所在建筑立面应为消防车登高操作面。",[565,567,569,571,573],{"key":20,"text":566,"correct":22},"高层住宅建筑",{"key":24,"text":568,"correct":22},"山坡地临空建造的高层民用建筑",{"key":28,"text":570,"correct":22},"河道边临空建造的高层民用建筑",{"key":31,"text":572,"correct":26},"高层厂房",{"key":125,"text":574,"correct":26},"高层仓库",{"id":576,"libraryId":5,"type":112,"typeLabel":113,"stem":577,"options":578,"answer":142,"analysis":33},934352,"下列关于消防救援入口的描述，正确的是（ ）。",[579,581,583,585,587],{"key":20,"text":580,"correct":22},"单层厂房的外墙应在适当位置设置可供消防救援人员进入的窗口",{"key":24,"text":582,"correct":22},"单层仓库的外墙应在适当位置设置可供消防救援人员进入的窗口",{"key":28,"text":584,"correct":22},"高层公共建筑的外墙应在每层的适当位置设置可供消防救援人员进入的窗口",{"key":31,"text":586,"correct":26},"超高层住宅建筑的外墙应在每层的适当位置设置可供消防救援人员进入的窗口",{"key":125,"text":588,"correct":22},"多层厂房、仓库的外墙应在每层的适当位置设置可供消防救援人员进入的窗口",{"id":590,"libraryId":5,"type":112,"typeLabel":113,"stem":591,"options":592,"answer":603,"analysis":33},934353,"下列关于消防电梯的叙述中，错误的是（ ）。",[593,595,597,599,601],{"key":20,"text":594,"correct":26},"消防电梯应分别设置在不同防火分区内，且每个防火分区不应少于1台",{"key":24,"text":596,"correct":22},"消防电梯可以作为一个安全出口",{"key":28,"text":598,"correct":22},"建筑高度大于32m的高层厂房（仓库），每个防火分区内宜设置1台消防电梯",{"key":31,"text":600,"correct":26},"消防电梯前室的使用面积不应小于6m2",{"key":125,"text":602,"correct":22},"与防烟楼梯间合用的前室，不应小于10m2","BCE",{"id":605,"libraryId":5,"type":112,"typeLabel":113,"stem":606,"options":607,"answer":127,"analysis":33},934354,"除（ ）外，消防电梯前室内不应开设其他门、窗、洞口。",[608,610,612,614,616],{"key":20,"text":609,"correct":22},"前室的出入口",{"key":24,"text":611,"correct":22},"前室内设置的正压送风口",{"key":28,"text":613,"correct":26},"管道井检修门",{"key":31,"text":615,"correct":22},"住宅建筑每层开向同一防烟楼梯间与消防电梯合用前室不大于3樘的户门（乙级防火门）",{"key":125,"text":617,"correct":26},"住宅建筑每层开向同一防烟楼梯间与消防电梯合用前室不大于5樘的户门（乙级防火门）",{"id":619,"libraryId":5,"type":112,"typeLabel":113,"stem":620,"options":621,"answer":632,"analysis":33},934355,"下列关于耐火极限调整的叙述中，正确的有哪些（ ）。",[622,624,626,628,630],{"key":20,"text":623,"correct":22},"二级耐火等级建筑，当房间的建筑面积不大于100m2时，房间的隔墙可采用耐火极限不低于0.50h的难燃性墙体或耐火极限不低于0.30h的不燃性墙体",{"key":24,"text":625,"correct":26},"二级耐火等级建筑，当房间的建筑面积大于100m2时，房间隔墙不能采用难燃性墙体",{"key":28,"text":627,"correct":22},"一、二级耐火等级建筑的上人平屋顶，屋面板的耐火极限同相应耐火等级的楼板要求一致",{"key":31,"text":629,"correct":22},"二级耐火等级建筑内采用不燃材料的吊顶，其耐火极限不限",{"key":125,"text":631,"correct":22},"二、三级耐火等级建筑中门厅、走道的吊项应采用不燃材料","ACDE",{"id":634,"libraryId":5,"type":112,"typeLabel":113,"stem":635,"options":636,"answer":142,"analysis":33},934356,"以下属于外墙外保温系统防火检查内容的是（ ）。",[637,639,641,643,645],{"key":20,"text":638,"correct":22},"保温材料的燃烧性能",{"key":24,"text":640,"correct":22},"电气线路与电器配件的安装",{"key":28,"text":642,"correct":22},"每层楼板处的防火封堵",{"key":31,"text":644,"correct":26},"广告牌的设置",{"key":125,"text":646,"correct":22},"防护层的设置",{"id":648,"libraryId":5,"type":112,"typeLabel":113,"stem":649,"options":650,"answer":489,"analysis":33},934357,"以下（ ）场所应直通室外或安全出口。",[651,653,655,656,658],{"key":20,"text":652,"correct":22},"锅炉房、变压器室",{"key":24,"text":654,"correct":22},"消防控制室",{"key":28,"text":207,"correct":22},{"key":31,"text":657,"correct":26},"柴油发电机房",{"key":125,"text":659,"correct":26},"气体灭火设备房",{"id":661,"libraryId":5,"type":112,"typeLabel":113,"stem":662,"options":663,"answer":345,"analysis":33},934358,"以下（ ）建筑应采用封闭楼梯间作为疏散楼梯。",[664,666,668,670,672],{"key":20,"text":665,"correct":22},"甲、乙、丙类厂房",{"key":24,"text":667,"correct":22},"丁、戊类高层仓库",{"key":28,"text":669,"correct":26},"建筑高度为38m的医疗建筑",{"key":31,"text":671,"correct":26},"与敞开式外廊直接相连的五层教学楼",{"key":125,"text":673,"correct":22},"建筑高度为28m的办公楼，与电梯井相邻布置的疏散楼梯",{"id":675,"libraryId":5,"type":112,"typeLabel":113,"stem":676,"options":677,"answer":688,"analysis":33},934359,"下列关于二级耐火等级办公楼内消防电梯的说法中，描述正确的是（ ）。",[678,680,682,684,686],{"key":20,"text":679,"correct":22},"设置消防电梯的建筑物的地下室应设置消防电梯",{"key":24,"text":681,"correct":26},"消防电梯轿厢的内部装修采用岩棉装饰板",{"key":28,"text":683,"correct":22},"消防电梯前室墙采用加气混凝土砌块砌筑，其耐火极限为2.0h",{"key":31,"text":685,"correct":22},"消防电梯前室的使用面积为6m2",{"key":125,"text":687,"correct":26},"消防电梯应每层停靠","ACD",{"id":690,"libraryId":5,"type":112,"typeLabel":113,"stem":691,"options":692,"answer":186,"analysis":33},934360,"某办公楼，设置1部消防电梯和2部防烟楼梯间，消防电梯单独设置。在检查消防电梯及其前室时，下列做法中，符合规定的有（ ）。",[693,695,697,699,701],{"key":20,"text":694,"correct":22},"消防电梯从首层到顶层的运行时间时60s",{"key":24,"text":696,"correct":22},"在首层的消防电梯入口处设置供消防队员专用的操作按钮",{"key":28,"text":698,"correct":26},"消防电梯的前室的入口处采用防火卷帘分隔",{"key":31,"text":700,"correct":26},"地下层为无人员经常停留的汽车库，消防电梯不停靠",{"key":125,"text":702,"correct":26},"消防电梯前室的建筑面积为6m2",{"id":704,"libraryId":5,"type":112,"typeLabel":113,"stem":705,"options":706,"answer":560,"analysis":33},934361,"下列关于防火卷帘设置的叙述中错误的是（ ）。",[707,709,711,713,715],{"key":20,"text":708,"correct":26},"替代防火墙的防火卷帘其两侧设置的冷却水幕，计算水量时，其火灾延续时间按不小于3.00h考虑",{"key":24,"text":710,"correct":22},"除中庭外，当防火分隔部位的宽度为72m时，防火卷帘的宽度为22m",{"key":28,"text":712,"correct":22},"除中庭外，当防火分隔部位的宽度为36m时，防火卷帘的宽度为13m",{"key":31,"text":714,"correct":26},"除中庭外，当防火分隔部位的宽度为24m时，防火卷帘的宽度为10m",{"key":125,"text":716,"correct":26},"需在火灾时自动降落的防火卷帘，应具有信号反馈的功能",[718,721,724,727,730,733],{"id":15,"name":719,"category":7,"favorite":720},"领导干部任职前廉政法规知识测试题",92,{"id":722,"name":723,"category":7,"favorite":15},595,"建筑结构与设备",{"id":725,"name":726,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":728,"name":729,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":731,"name":732,"category":7,"favorite":8},534,"BIM工程师",{"id":734,"name":732,"category":7,"favorite":8},535]