[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-5":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":652},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,5,50,2960,[13,34,46,58,70,82,94,112,124,139,151,163,175,190,204,216,228,240,252,264,278,290,302,314,326,338,350,362,375,390,405,419,431,443,455,467,479,491,503,517,529,541,553,568,580,592,604,616,628,640],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},931884,1,"单选题","（2017真题）下列场所中，不需要设置火灾自动报警系统的是（ ） 。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","高层建筑首层停车数为200辆的汽车库",false,{"key":24,"text":25,"correct":22},"B","采用汽车专用升降机做汽车疏散出口的汽车库",{"key":27,"text":28,"correct":22},"C","停车数为350辆的单层汽车库",{"key":30,"text":31,"correct":32},"D","采用机械设备进行垂直或水平移动形式停放汽车的敞开汽车库",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":30,"analysis":33},931885,"（2018真题）根据现行国家标准《火灾自动报警系统设计规范》（GB50116），（ ）不应作为联动启动火灾声光警报器的触发器件。",[38,40,42,44],{"key":20,"text":39,"correct":22},"手动火灾报警按钮",{"key":24,"text":41,"correct":22},"红紫外线复合火灾探测器",{"key":27,"text":43,"correct":22},"吸气式火灾探测器",{"key":30,"text":45,"correct":32},"输出模块",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":30,"analysis":33},931886,"（2018真题）根据现行国家标准《火灾自动报警系统设计规范》（GB50116），关于火灾探测器设置的说法正确的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"在2.8m宽的走道顶棚上安装的点型感温火灾探测器之间的间距不应超过15m",{"key":24,"text":53,"correct":22},"相邻两组线型光束感烟火灾探测器的水平距离不应超过15m",{"key":27,"text":55,"correct":22},"管路采样吸气式感烟火灾探测器的一个探测单元的采样管总长不宜超过100m",{"key":30,"text":57,"correct":32},"点型感烟火灾探测器距墙壁的水平距离不应小于0.5m",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":30,"analysis":33},931887,"（2018真题）根据现行国家标准《火灾自动报警系统设计规范》GB50116，关于电气火灾监控探测器设置的说法，正确的是（ ）",[62,64,66,68],{"key":20,"text":63,"correct":22},"剩余电流式电气火灾监控探测器应以设置在低压配电系统的末端配电柜内",{"key":24,"text":65,"correct":22},"在无消防控制室且电气火灾监控探测器设置数量不超过10只时，非独立式电气火灾监控探测器可接入火灾报警控制器的探测器回路",{"key":27,"text":67,"correct":22},"电气火灾监控探测器发出报警信号后，应在3s内联动电气火灾监控器切断保护对象的供电电源",{"key":30,"text":69,"correct":32},"设有消防控制室时，电气火灾监控器的报警信息应在集中火灾报警控制器上显示",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},931888,"（2018真题）根据现行囯家标准《火灾自动报警系统设计规范》（GB50116）（ ）属于线型火灾探测器。",[74,76,78,80],{"key":20,"text":75,"correct":22},"红紫外线符合火灾探测器",{"key":24,"text":77,"correct":32},"红外光束火灾探测器",{"key":27,"text":79,"correct":22},"图像型火灾探测器",{"key":30,"text":81,"correct":22},"管路吸气式火灾探测器",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},931889,"（2015真题）根据《火灾自动报警系统设计规范》（GB50116-2013）的规定，消防控制室内的设备面盘至墙的距离不应小于( )m。",[86,88,90,92],{"key":20,"text":87,"correct":22},"1.5",{"key":24,"text":89,"correct":32},"3",{"key":27,"text":91,"correct":22},"2",{"key":30,"text":93,"correct":22},"2.5",{"id":95,"libraryId":5,"type":96,"typeLabel":97,"stem":98,"options":99,"answer":111,"analysis":33},931890,2,"多选题","（2018真题）根据现行国家标准《火灾自动报警系统设计规范》（GB 50116），消防联动控制器应具有切断火灾区域及相关区域非消防电源的功能。当局部区域发生电气设备火灾时，不可立即切断的非消防电源有（）。",[100,102,104,106,108],{"key":20,"text":101,"correct":32},"客用电梯电源",{"key":24,"text":103,"correct":22},"空调电源",{"key":27,"text":105,"correct":32},"生活给水泵电源",{"key":30,"text":107,"correct":22},"自动扶梯电源",{"key":109,"text":110,"correct":32},"E","正常照明电源","ACE",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":30,"analysis":33},931891,"（2017真题）根据规范要求，剩余电流式电气火灾监控探测器应设置在（ ）",[116,118,120,122],{"key":20,"text":117,"correct":22},"高压配电系统末端",{"key":24,"text":119,"correct":22},"采用IT、TN系统的配电线路上",{"key":27,"text":121,"correct":22},"泄露电流大于500mA的供电线路上",{"key":30,"text":123,"correct":32},"低压配电系统首端",{"id":125,"libraryId":5,"type":96,"typeLabel":97,"stem":126,"options":127,"answer":138,"analysis":33},931892,"（2018真题）根据现行国家标准《火灾自动报警系统设计规范》（GB50116），关于火灾自动报警系统线缆选择的说法，正确的有（ ）。",[128,130,132,134,136],{"key":20,"text":129,"correct":22},"消防联动控制线路应选择阻燃铜芯电缆",{"key":24,"text":131,"correct":22},"消防专用电话传输线路应选择耐高温铜芯导线",{"key":27,"text":133,"correct":32},"供电线路应选择耐火铜芯电缆",{"key":30,"text":135,"correct":32},"火灾探测器报警总线应选择阻燃铜芯导线",{"key":109,"text":137,"correct":22},"消防应急广播传输线路应选择耐火铜芯导线","CD",{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":141,"options":142,"answer":20,"analysis":33},931894,"（2019年真题）关于控制中心报警系统组成的说法，错误的是（ ）",[143,145,147,149],{"key":20,"text":144,"correct":32},"只设置一个消防控制室时，可只设置一台起集中控制功能的火灾报警控制器（联动型）",{"key":24,"text":146,"correct":22},"采用火灾报警控制器（联动型）时，可不设置消防联动控制器",{"key":27,"text":148,"correct":22},"不可采用火警传输设备替代消防控制室图形显示装置",{"key":30,"text":150,"correct":22},"不可采用背景音乐系统替代消防应急广播系统",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":30,"analysis":33},931895,"（2019年真题）关于火灾探测器分类的说法，正确的是（）",[155,157,159,161],{"key":20,"text":156,"correct":22},"点型感温火灾探测器按其应用和动作温度不同，分为A1、A2、 B、D型",{"key":24,"text":158,"correct":22},"线型感温火灾探测器按其敏感部件形式不同，分为缆式、分布光纤式和空气管式",{"key":27,"text":160,"correct":22},"吸气式感烟火灾探测器按其响应阈值范围不同，分为普通型和灵敏型",{"key":30,"text":162,"correct":32},"吸气式感烟火灾探测器按其采样方式不同，分为管路采样式和点型采样式",{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":165,"options":166,"answer":30,"analysis":33},931897,"（2019年真题）集中控制型消防应急照明和疏通指示系统灯具采用集中电源供电方式时，正确的做法是()。",[167,169,171,173],{"key":20,"text":168,"correct":22},"应急照明集中电源仅为灯具提供蓄电池电源",{"key":24,"text":170,"correct":22},"应急照明控制器直接控制灯具的应急启动",{"key":27,"text":172,"correct":22},"应急照明集中电源不直接连锁控制消防应急灯具的工作状态",{"key":30,"text":174,"correct":32},"应急照明控制器通过应急照明集中电源连接灯具",{"id":176,"libraryId":5,"type":96,"typeLabel":97,"stem":177,"options":178,"answer":189,"analysis":33},931898,"（2019年真题）某大型商业综合体首层某防火分区采用机械排烟系统，共划分4个防烟分区。防烟分区间采用电动档烟垂壁分隔，每个防烟分区均设5个排烟口。该防火分区机械排烟系统的下列控制设计方案中，错误的有()",[179,181,183,185,187],{"key":20,"text":180,"correct":32},"由防火分区内1只感烟火灾探测器和1只手动火灾报警按钮的报警信号(“与”逻辑)作为排烟口开启的联动出发信号",{"key":24,"text":182,"correct":32},"消防联动控制器接收到符合排烟口联动开启控制逻辑的出发信号后,联动控制开启排烟口的数量为10个",{"key":27,"text":184,"correct":32},"消防联动控制器接收到房后分区内2只感烟火灾探测器的报警信号后,应联动控制排烟口的开启和排烟风机的启动",{"key":30,"text":186,"correct":32},"由防火分区内2只感烟火灾探测器的报警信号(“与”逻辑)作为电动档烟垂壁下降的联动出发信",{"key":109,"text":188,"correct":22},"消防联动控制器分时联动控制排烟口的开启和电动档烟垂壁的下降","ABCD",{"id":191,"libraryId":5,"type":96,"typeLabel":97,"stem":192,"options":193,"answer":203,"analysis":33},931899,"（2019年真题）某办公楼的自动喷水灭火系统采用湿式系统。通过（）可直接自动启动该湿式系统的消防水泵。",[194,195,197,199,201],{"key":20,"text":39,"correct":22},{"key":24,"text":196,"correct":22},"每个楼层设置的水流指示器",{"key":27,"text":198,"correct":32},"消防水泵出水干管上设置的压力开关",{"key":30,"text":200,"correct":32},"高位消防水箱出水管上的流量开关",{"key":109,"text":202,"correct":32},"报警阀组压力开关","CDE",{"id":205,"libraryId":5,"type":15,"typeLabel":16,"stem":206,"options":207,"answer":30,"analysis":33},931900,"（2019年真题）某商场设置火灾自动报警系统，首层2个防火分区共用火灾报警控制器的2#回路总线。其中防火分区-设置30只感烟火灾探测器、10只手动火灾报警按钮、10只总线模块（②输入2输出）；防火分区二设置28只感烟火灾探测器、8只手动火灾报警按钮、10只总线模块（2输入2输出）。控制器2#回路总线设置短路隔离器的数量至少为（）。",[208,210,212,214],{"key":20,"text":209,"correct":22},"3只",{"key":24,"text":211,"correct":22},"6只",{"key":27,"text":213,"correct":22},"5只",{"key":30,"text":215,"correct":32},"4只",{"id":217,"libraryId":5,"type":15,"typeLabel":16,"stem":218,"options":219,"answer":30,"analysis":33},931901,"（2019年真题）某住宅小区，建有10栋建筑高度为110m的住宅，在小区物业服务中心设置消防控制室。该小区的火灾自动报警系统（）",[220,222,224,226],{"key":20,"text":221,"correct":22},"应采用集中报警系统",{"key":24,"text":223,"correct":22},"应采用区域报警系统",{"key":27,"text":225,"correct":22},"应采用区域集中报警系统",{"key":30,"text":227,"correct":32},"应采用控制中心报警系统",{"id":229,"libraryId":5,"type":15,"typeLabel":16,"stem":230,"options":231,"answer":20,"analysis":33},931902,"（2019年真题）关于消防控制室控制和显示功能的说法，错误的是（）",[232,234,236,238],{"key":20,"text":233,"correct":32},"消防联动控制器应能控制并显示信号阀的工作状态",{"key":24,"text":235,"correct":22},"通过消防联动控制器手动直接控制消防水泵的控制信号的电压等级不应采用DC36V",{"key":27,"text":237,"correct":22},"消防控制室应能手动或按预设控制逻辑联动控制选择广播分区并显示广播分区的工作状态",{"key":30,"text":239,"correct":22},"消防联动控制器应能显示喷淋泵电源的工作状态",{"id":241,"libraryId":5,"type":15,"typeLabel":16,"stem":242,"options":243,"answer":27,"analysis":33},931903,"（2019年真题）某化工厂主控楼设置了消防控制室，生产装置拟设置可燃气体探测报警系统。该火灾可燃气体探测报警系统的下列设计方案中，错误的是（）",[244,246,248,250],{"key":20,"text":245,"correct":22},"可燃气体探测器设置在可燃气体管道阀门、进料口等部位附近",{"key":24,"text":247,"correct":22},"可燃气体探测器同时接入生产装置的DCS系统和可燃气体报警控制器",{"key":27,"text":249,"correct":32},"可燃气体探测器直接将报警信号传输至消防控制室图形显示装置",{"key":30,"text":251,"correct":22},"可燃气体报警控制器设置在防护区附近",{"id":253,"libraryId":5,"type":15,"typeLabel":16,"stem":254,"options":255,"answer":20,"analysis":33},931904,"（2019年真题）某三层办公建筑在底层设有低压配电间，每个楼层设有1个楼层配电箱，实测高压配电间的出线端固定准漏电流为800m A，每层准漏电流相同，该建筑设置电气火灾监控系统，未设置消防控制室，剩余电流式电气火灾监控探测器的下列设计方案中，错误的是（）",[256,258,260,262],{"key":20,"text":257,"correct":32},"低压配电间的出线端设置1只探测器，探测器的报警电流设为1200mA",{"key":24,"text":259,"correct":22},"各楼层配电箱的进线端分别设置一只探测器，探测器的报警电流设为400mA",{"key":27,"text":261,"correct":22},"探测器采用独立式探测器",{"key":30,"text":263,"correct":22},"探测器报警时，不切断楼层配电箱的电源",{"id":265,"libraryId":5,"type":96,"typeLabel":97,"stem":266,"options":267,"answer":138,"analysis":33},931905,"（2019年真题）关于建筑供配电系统电器防火要求的说法，正确的有()",[268,270,272,274,276],{"key":20,"text":269,"correct":22},"空调器具、防排烟风机的配电回路应设置过载保护装置",{"key":24,"text":271,"correct":22},"服装仓库内设置的配电箱与周边可燃物的距离不应小于5m或采取相应的隔热措施",{"key":27,"text":273,"correct":32},"在采用金属导管保护时，墙壁插座的配电线路可紧贴通风管道外壁敷设",{"key":30,"text":275,"correct":32},"在有可燃物的闷顶敷设时，照明灯具的配电线路应采用金属导管保护",{"key":109,"text":277,"correct":22},"建筑面积为300㎡的老年照料设施的非消防用电负荷可不设置电气火灾监控系统",{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":24,"analysis":33},931906,"（2020年真题）某饭店的厨房采用液化石油气作为燃料，关于厨房内可燃气体探测器的选型和设置，正确的是（ ）。",[282,284,286,288],{"key":20,"text":283,"correct":22},"探测器采用甲烷可燃气体探测器",{"key":24,"text":285,"correct":32},"探测器设置在厨房的下部",{"key":27,"text":287,"correct":22},"探测器采用一氧化碳可燃气体探测器",{"key":30,"text":289,"correct":22},"探测器设置在厨房的顶棚",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":20,"analysis":33},931907,"（2020年真题）环境噪声为65dB的生产车间中，火灾声光警报器的最小声压级为（ ）dB。",[294,296,298,300],{"key":20,"text":295,"correct":32},"80",{"key":24,"text":297,"correct":22},"70",{"key":27,"text":299,"correct":22},"75",{"key":30,"text":301,"correct":22},"85",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":27,"analysis":33},931908,"（2020年真题）某病房楼，手术室、重症监护室配电回路的接地系统局部采用IT系统，其余部位用电设备配电回路的接地系统采用TN-S系统。下列部位或用电设备中，配电回路适宜设置剩余电流式电气火灾监控探测器的是（ ）。",[306,308,310,312],{"key":20,"text":307,"correct":22},"手术室",{"key":24,"text":309,"correct":22},"排烟风机",{"key":27,"text":311,"correct":32},"排污泵",{"key":30,"text":313,"correct":22},"喷淋泵",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":20,"analysis":33},931909,"（2020年真题）根据探测的火灾特征参数分类，火灾探测器不包括（ ）。",[318,320,322,324],{"key":20,"text":319,"correct":32},"电气火灾监控探测器",{"key":24,"text":321,"correct":22},"感烟感温复合火灾探测器",{"key":27,"text":323,"correct":22},"气体火灾探测器",{"key":30,"text":325,"correct":22},"感光火灾探测器",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":27,"analysis":33},931910,"（2020年真题）某大型商业综合体中设置了3个独立的功能区，关于该商业综合体消防控制室的设置和功能，错误的是（ ）。",[330,332,334,336],{"key":20,"text":331,"correct":22},"该综合体设有1个主消防控制室和2个分消防控制室",{"key":24,"text":333,"correct":22},"分消防控制室可控制该功能区内设置的消防设备",{"key":27,"text":335,"correct":32},"主消防控制室可控制分消防控制室管辖功能区设置的消防设备",{"key":30,"text":337,"correct":22},"分消防控制室可显示另一个分消防控制室设各的运行状态信息",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":27,"analysis":33},931911,"（2020年真题）关于消防联动控制器对机械排烟系统的控制及其显示功能的说法，错误的是（ ）。",[342,344,346,348],{"key":20,"text":343,"correct":22},"消防联动控制器应直接手动远程控制排烟风机的启动",{"key":24,"text":345,"correct":22},"消防联动控制器应显示排烟口开启的动作反馈信号",{"key":27,"text":347,"correct":32},"消防联动控制器应直接手动远程控制排烟阀的开启",{"key":30,"text":349,"correct":22},"消防联动控制器应显示排烟防火阀的反馈信号",{"id":351,"libraryId":5,"type":15,"typeLabel":16,"stem":352,"options":353,"answer":27,"analysis":33},931912,"（2020年真题）根据探测火灾特征参数和供电方式分类,独立式火灾探测报警器不包括（ ）。",[354,356,358,360],{"key":20,"text":355,"correct":22},"内部电池供电的感烟探测报警器",{"key":24,"text":357,"correct":22},"外部电池供电的感温探测报警器",{"key":27,"text":359,"correct":32},"外部电源供电的感烟探测报警器",{"key":30,"text":361,"correct":22},"外部电源供电且配有内部备用电池的感温探测报警器",{"id":363,"libraryId":5,"type":96,"typeLabel":97,"stem":364,"options":365,"answer":189,"analysis":33},931913,"（2020年真题）下列设备中,属于消防联动控制系统组成部件的有（ ）。",[366,368,370,372,374],{"key":20,"text":367,"correct":32},"消防电动装置",{"key":24,"text":369,"correct":32},"消防电话",{"key":27,"text":371,"correct":32},"消火栓按钮",{"key":30,"text":373,"correct":32},"消防水泵控制柜",{"key":109,"text":39,"correct":22},{"id":376,"libraryId":5,"type":96,"typeLabel":97,"stem":377,"options":378,"answer":389,"analysis":33},931914,"（2020年真题）某办公楼设有闭式自动喷水灭火系统，地下一层为消防水泵房，消防水泵房内设置两台喷淋泵。关于喷淋泵控制的说法，正确的有（ ）。",[379,381,383,385,387],{"key":20,"text":380,"correct":32},"喷淋泵应能手动启、停",{"key":24,"text":382,"correct":22},"喷淋泵应能自动启、停",{"key":27,"text":384,"correct":32},"喷淋泵控制柜在平时应设置在自动控制状态",{"key":30,"text":386,"correct":32},"喷淋泵控制柜应设置机械应急启泵功能",{"key":109,"text":388,"correct":32},"消防控制柜应设置专用线路连接的手动直接启泵按钮","ACDE",{"id":391,"libraryId":5,"type":96,"typeLabel":97,"stem":392,"options":393,"answer":404,"analysis":33},931915,"（2020年真题）某数据中心的机房设置了气体灭火系统，气体灭火控制器设置在瓶组间内，关于该数据中心消防控制室对气体灭火系统的控制及其显示功能的说法，正确的有（ ）。",[394,396,398,400,402],{"key":20,"text":395,"correct":32},"消防控制室应能显示系统的手动、自动工作状态",{"key":24,"text":397,"correct":22},"消防控制室应能远程手动控制驱动装置启动",{"key":27,"text":399,"correct":32},"消防控制室应能显示防护区内火灾声光警报器启动的反馈信号",{"key":30,"text":401,"correct":22},"消防控制室应能显示防护区域防火门的关闭反馈信号",{"key":109,"text":403,"correct":22},"消防控制室应能显示紧急启动按钮的启动信号","AC",{"id":406,"libraryId":5,"type":96,"typeLabel":97,"stem":407,"options":408,"answer":111,"analysis":33},931916,"（2020年真题）火灾自动报警系统的传输线路暗敷时，系统线路采取的防护措施中，正确的有（ ）。",[409,411,413,415,417],{"key":20,"text":410,"correct":32},"线路采用金属管保护",{"key":24,"text":412,"correct":22},"线路采用B1级刚性塑料封闭线槽保护",{"key":27,"text":414,"correct":32},"线路采用可挠（金属）电气导管保护",{"key":30,"text":416,"correct":22},"线路采用金属封闭线槽保护",{"key":109,"text":418,"correct":32},"线路采用B1级刚性塑料管保护",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":27,"analysis":33},931917,"（2017真题）建筑的场所或部位中,应设置排烟设施的是（ ）。",[423,425,427,429],{"key":20,"text":424,"correct":22},"设置在二层,房间建筑面积为50m2的歌舞娱乐放映游艺场所",{"key":24,"text":426,"correct":22},"地下一层的防烟楼梯间前室",{"key":27,"text":428,"correct":32},"建筑面积120m2的中庭",{"key":30,"text":430,"correct":22},"建筑内长度为15m的疏散走道",{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":27,"analysis":33},931918,"（2016真题）下列建筑中，当其楼梯间的前室或合用前室采用敞开阳台时，楼梯间可不设置防烟系统的是（ ）。",[435,437,439,441],{"key":20,"text":436,"correct":22},"建筑高度为68m的旅馆建筑",{"key":24,"text":438,"correct":22},"建筑高度为52m的生产建筑",{"key":27,"text":440,"correct":32},"建筑高度为81m的住宅建筑",{"key":30,"text":442,"correct":22},"建筑高度为52m的办公建筑",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":27,"analysis":33},931919,"（2015真题）下列关于高层建筑中设置机械加压送风系统的说法，错误的是（ ）。",[447,449,451,453],{"key":20,"text":448,"correct":22},"地下室的楼梯间和地上部分的防烟楼梯间均需设置机械加压送风系统时，机械加压送风系统宜分别独立设置",{"key":24,"text":450,"correct":22},"建筑高度大于50m的公共建筑，其防烟楼梯间、消防电梯前室应设置机械加压送风",{"key":27,"text":452,"correct":32},"建筑高度大于50m的住宅建筑，其防烟楼梯间、消防电梯前室应设置机械加压送风系统",{"key":30,"text":454,"correct":22},"建筑高度大于50m的工业建筑，其防烟楼梯间、消防电梯前室应设置机械加压送风",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":20,"analysis":33},931920,"（2018真题）关于建筑机械防烟系统联动控制的说法，正确的是（ ）。",[459,461,463,465],{"key":20,"text":460,"correct":32},"由同一防火分区内的两只独立火灾探测器作为相应机械加压送风机开启的联动触发信号",{"key":24,"text":462,"correct":22},"火灾确认后，火灾自动报警系统应能在30s内联动开启相应的机械加压送风机",{"key":27,"text":464,"correct":22},"加压送风口所在防火分区确认火灾后，火灾自动报警系统应仅联动开启所在楼层前室送风口",{"key":30,"text":466,"correct":22},"火灾确认后，火灾自动报警系统应能在20s内联动开启相应的常压加压送风口",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":30,"analysis":33},931921,"（2018真题）根据现行国家标准《建筑防烟排烟系统技术标准》（GB51251）下列民用建筑楼梯间的防烟设计方案中,错误的是（ ）。",[471,473,475,477],{"key":20,"text":472,"correct":22},"建筑高度97m的住宅建筑,防烟楼梯间及其前室均采用自然通风方式防烟",{"key":24,"text":474,"correct":22},"建高度48m的办公楼,防烟楼梯间及其前室均采用自然通风方式防烟",{"key":27,"text":476,"correct":22},"采用自然通风的防烟楼梯间,楼间外墙上开设的可开启外窗最大布置间隔为3层",{"key":30,"text":478,"correct":32},"采用自然通风方式的封闭楼梯间，在最高部位设置1.0㎡的固定窗",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":20,"analysis":33},931922,"（2018真题）某建筑高度为156m的公共建筑设有机械加压送风系统。根据现行囯家标准《建筑防烟排烟系统技术标准》（GB51251），该机械加压送风系统的下列设计方案中，错误的是（ ）。",[483,485,487,489],{"key":20,"text":484,"correct":32},"封闭避难层的送风是按避难层净面积每平方米不小于25m3\u002Fh确定",{"key":24,"text":486,"correct":22},"楼梯间与走道之间的压差为40Pa",{"key":27,"text":488,"correct":22},"前室与走道之间的压差为25Pa",{"key":30,"text":490,"correct":22},"机械加压送风系统按服务区段高度分段独立设置",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":24,"analysis":33},931923,"（2018真题）某建筑净空高度为5m的商业营业厅，设有机械排烟系统，共划分为4个防烟分区，最小防烟分区面积为500㎡。根据《建筑防烟排烟系统技术标准》（GB51251），该机械排烟系统设置的下列方案中，正确的是（ ）。",[495,497,499,501],{"key":20,"text":496,"correct":22},"排烟口与最近安全出口的距离为1.2m",{"key":24,"text":498,"correct":32},"最小防烟分区的排烟量为30000m3\u002Fh",{"key":27,"text":500,"correct":22},"防烟分区的最大长边长度为40m",{"key":30,"text":502,"correct":22},"最大防烟分区的建筑面积为1500㎡",{"id":504,"libraryId":5,"type":96,"typeLabel":97,"stem":505,"options":506,"answer":203,"analysis":33},931924,"（2015真题）某建筑高度为23米的5层商业建筑，长度100米，宽度50米，每层建筑面积5000m2,设置有自动喷水灭火系统、火灾自动报警系统和防排烟系统等消防设施。下列关于机械排烟系统应满足要求的说法中，正确的有（ ）。",[507,509,511,513,515],{"key":20,"text":508,"correct":22},"与垂直管道连接的每层水平支管上自由切换应设置在楼层配电间内",{"key":24,"text":510,"correct":22},"排烟风机配电线路的末端自动切换应设置在楼层配电间内",{"key":27,"text":512,"correct":32},"采用的排烟风机应能在280°C时连续工作30min",{"key":30,"text":514,"correct":32},"火灾时应有火灾自动报警系统联动开启排烟口",{"key":109,"text":516,"correct":32},"排烟口应设置现场手动开启装置",{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":20,"analysis":33},931925,"（2016真题）自然排烟是利用火灾烟气的热浮力和外部风压等作用，通过建筑物的外墙或屋顶开口讲烟气排至室外的排烟方式。下列关于自然排烟的说法中，错误的是（ ）。",[521,523,525,527],{"key":20,"text":522,"correct":32},"自然排烟窗的开启方向应采用上悬外开式",{"key":24,"text":524,"correct":22},"具备自然排烟条件的多层建筑，宜采用自然排烟方式",{"key":27,"text":526,"correct":22},"排烟窗应设置在建筑排烟空间室内净高的1\u002F2以上",{"key":30,"text":528,"correct":22},"排烟口的排放速率主要取决于烟气的厚度和温度",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":20,"analysis":33},931926,"（2016真题）下列厂房或仓库中，按规范应设置防排烟设施的是（ ）。",[533,535,537,539],{"key":20,"text":534,"correct":32},"每层建筑面积为1200㎡的2层丙类仓库",{"key":24,"text":536,"correct":22},"丙类厂房内建筑面积为120㎡的生产监控室",{"key":27,"text":538,"correct":22},"建筑面积为3000㎡的丁类生产车间",{"key":30,"text":540,"correct":22},"单层丙类厂房内长度为35m的疏散走道",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":27,"analysis":33},931927,"（2015真题）下列关于自然排烟的说法，错误的是（ ）。",[545,547,549,551],{"key":20,"text":546,"correct":22},"建筑面积为800m2的地下停车库可采用自然排烟方式",{"key":24,"text":548,"correct":22},"采用自然排烟的场所可不划分防烟分区",{"key":27,"text":550,"correct":32},"防烟楼梯间及其前室不应采用自然排烟方式",{"key":30,"text":552,"correct":22},"建筑高度小于50m的公共建筑，宜优先考虑采用自然排烟方式",{"id":554,"libraryId":5,"type":96,"typeLabel":97,"stem":555,"options":556,"answer":567,"analysis":33},931928,"（2017真题）关于防烟排烟系统联动控制的做法，符合规范要求的有（ ）",[557,559,561,563,565],{"key":20,"text":558,"correct":32},"同一防烟分区内的一只感烟探测器和一只感温探测器报警，联动控制该防烟分区的排烟口开启",{"key":24,"text":560,"correct":22},"同一防烟分区内的两只感烟探测器报警，联动控制该防烟分区及相邻防烟分区的排烟口开启",{"key":27,"text":562,"correct":22},"排烟口附近的一只手动报警按钮报警，控制该排烟口开启",{"key":30,"text":564,"correct":32},"排烟阀开启动作信号联动控制排烟风机启动",{"key":109,"text":566,"correct":32},"通过消防联动控制器上的手动控制盘直接控制排烟风机启动、停止","ADE",{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":24,"analysis":33},931929,"（2017真题）根据防排烟系统的联动控制设计要求，当（ ）时，送风口不会动作。",[572,574,576,578],{"key":20,"text":573,"correct":22},"同一防护区内一只火灾探测器和一只手动报警按钮报警",{"key":24,"text":575,"correct":32},"联动控制器接收到送风机启动的反馈信号",{"key":27,"text":577,"correct":22},"同一防护区内两只独立的感烟探测器报警",{"key":30,"text":579,"correct":22},"在联动控制器上手动控制送风口开启",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":30,"analysis":33},931930,"（2017真题）采用t2火模型描述火灾发展过程时，装满书籍的厚布邮袋火灾是（ ）t2火",[584,586,588,590],{"key":20,"text":585,"correct":22},"超快速",{"key":24,"text":587,"correct":22},"中速",{"key":27,"text":589,"correct":22},"慢速",{"key":30,"text":591,"correct":32},"快速",{"id":593,"libraryId":5,"type":15,"typeLabel":16,"stem":594,"options":595,"answer":27,"analysis":33},931931,"（2017真题）机械加压送风系统启动后，按照余压值从大到小排列，排序正确的是（ ）",[596,598,600,602],{"key":20,"text":597,"correct":22},"走道、前室、防烟楼梯间",{"key":24,"text":599,"correct":22},"前室、防烟楼梯间、走道",{"key":27,"text":601,"correct":32},"防烟楼梯间、前室、走道",{"key":30,"text":603,"correct":22},"防烟楼梯间、走道、前室",{"id":605,"libraryId":5,"type":15,"typeLabel":16,"stem":606,"options":607,"answer":30,"analysis":33},931932,"（2017真题）净空高度不大于6.0m的民用建筑采用自然排烟的防烟分区内任一点至最近排烟窗的水平距离不应大于（ ）m",[608,610,612,614],{"key":20,"text":609,"correct":22},"20",{"key":24,"text":611,"correct":22},"35",{"key":27,"text":613,"correct":22},"50",{"key":30,"text":615,"correct":32},"30",{"id":617,"libraryId":5,"type":15,"typeLabel":16,"stem":618,"options":619,"answer":30,"analysis":33},931933,"（2019年真题）某建筑高度为248m的公共建筑，避难层设置机械加压送风系统。关于该建筑避难层防火设计的说法，错误的是（）",[620,622,624,626],{"key":20,"text":621,"correct":22},"设备间应采用耐火极限不低于2.0h的防火隔墙与避难区分隔。",{"key":24,"text":623,"correct":22},"避难层应在外墙上设置可开启外窗，该外窗的有限面积不应小于该避难层地面面积的1%",{"key":27,"text":625,"correct":22},"设备管道去应采用耐火极限不低于3.0h的防火隔墙与避难区分隔",{"key":30,"text":627,"correct":32},"避难层应在外墙上设置固定窗，窗口面积不应小于该避难层地面面积的2%",{"id":629,"libraryId":5,"type":15,"typeLabel":16,"stem":630,"options":631,"answer":27,"analysis":33},931934,"（2019年真题）某4层商场，建筑高度为21m。每层建筑面积为10000㎡,划分为2个防火分区，每层净高为4m,走道净高为3m,设有自动喷水灭火系统、机械排烟系统、该商场机械排烟系统的下列设计方案中，正确的是()。",[632,634,636,638],{"key":20,"text":633,"correct":22},"设置在屋顶的固定窗采用可熔性采光窗，采光窗的有效面积为楼地面面积的10%",{"key":24,"text":635,"correct":22},"排烟口设置在开孔率20%的非封闭式吊顶内",{"key":27,"text":637,"correct":32},"走道侧墙上的排烟口，其上缘距吊顶0.5m",{"key":30,"text":639,"correct":22},"每层采用一套机械排烟系统",{"id":641,"libraryId":5,"type":15,"typeLabel":16,"stem":642,"options":643,"answer":30,"analysis":33},931935,"（2019年真题）某多层商业建筑，营业厅净高5.5m，采用自然排烟方式。该营业厅的防烟分区内任一点与最近的自然排烟窗之间的水平距离不应大于（）。",[644,646,648,650],{"key":20,"text":645,"correct":22},"37.5m",{"key":24,"text":647,"correct":22},"室内净高的2.8倍",{"key":27,"text":649,"correct":22},"室内净高的3倍",{"key":30,"text":651,"correct":32},"30m",[653,656,659,662,665,668],{"id":15,"name":654,"category":7,"favorite":655},"领导干部任职前廉政法规知识测试题",92,{"id":657,"name":658,"category":7,"favorite":15},595,"建筑结构与设备",{"id":660,"name":661,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":663,"name":664,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":666,"name":667,"category":7,"favorite":8},534,"BIM工程师",{"id":669,"name":667,"category":7,"favorite":8},535]