[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-48":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":612},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,48,50,2960,[13,34,45,57,69,81,93,105,117,129,141,153,163,175,187,199,211,222,233,245,257,274,289,304,319,331,343,351,359,371,381,389,397,407,419,431,443,453,465,477,489,501,511,523,535,547,562,576,588,600],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},934057,1,"单选题","人防工程内医院房间门至最近安全出口的最大距离应为（ ）m。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","15",false,{"key":24,"text":25,"correct":26},"B","24",true,{"key":28,"text":29,"correct":22},"C","30",{"key":31,"text":32,"correct":22},"D","40","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},934058,"歌舞娱乐放映游艺场所不应设置在人防工程内地下二层及以下层。当设置在地下一层时，室内地面与室外出入口地坪高差不应大于（ ）m。",[38,40,42,44],{"key":20,"text":39,"correct":22},"3",{"key":24,"text":41,"correct":22},"6",{"key":28,"text":43,"correct":26},"10",{"key":31,"text":25,"correct":22},{"id":46,"libraryId":5,"type":15,"typeLabel":16,"stem":47,"options":48,"answer":28,"analysis":33},934059,"人防工程中设置下沉式广场，当确需设置防风雨棚时，棚不得封闭，当敞开部分采用防风雨百叶时，百叶的有效通风排烟面积可按百叶洞口面积的（ ）％计算。",[49,51,53,55],{"key":20,"text":50,"correct":22},"25",{"key":24,"text":52,"correct":22},"50",{"key":28,"text":54,"correct":26},"60",{"key":31,"text":56,"correct":22},"75",{"id":58,"libraryId":5,"type":15,"typeLabel":16,"stem":59,"options":60,"answer":28,"analysis":33},934060,"某人防工程地下一层设有夜总会，下列说法中，错误的是（ ）。",[61,63,65,67],{"key":20,"text":62,"correct":22},"隔墙上的门应采用乙级防火门",{"key":24,"text":64,"correct":22},"当设有自动喷水灭火系统时，每个防火分区的最大允许建筑面积为1000m2",{"key":28,"text":66,"correct":26},"不应布置在袋形走道的两侧或尽端",{"key":31,"text":68,"correct":22},"建筑面积大于50m2的厅、室，疏散出口不应少于2个",{"id":70,"libraryId":5,"type":15,"typeLabel":16,"stem":71,"options":72,"answer":20,"analysis":33},934061,"下列设置在人防工程内的场所中，其疏散距离不符合规范要求的是（ ）。",[73,75,77,79],{"key":20,"text":74,"correct":26},"观众厅内任一点至最近房间门的直线距离不宜大于30m",{"key":24,"text":76,"correct":22},"位于袋形走道两侧或尽端的房间，其房间门至最近安全出口的最大距离应减半",{"key":28,"text":78,"correct":22},"医院房间门至最近安全出口的最大距离为24m",{"key":31,"text":80,"correct":22},"旅馆房间门至最近安全出口的最大距离为30m",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":31,"analysis":33},934062,"某人防工程内设有商店营业厅、展览厅、电影院和礼堂等多个场所，场所内均设有火灾自动报警系统和自动喷水灭火系统，并采用A级装修材料装修，下列防火分区划分中，错误的是（ ）。",[85,87,89,91],{"key":20,"text":86,"correct":22},"商店营业厅的防火分区中最大一个的建筑面积为1600m2",{"key":24,"text":88,"correct":22},"展览厅的防火分区中最大一个的建筑面积为2000m2",{"key":28,"text":90,"correct":22},"电影院的防火分区中最大一个的建筑面积为1000m2",{"key":31,"text":92,"correct":26},"礼堂观众厅的防火分区中最大一个的建筑面积为1200m2",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":28,"analysis":33},934063,"下列有关人防工程疏散楼梯设置形式的说法中，错误的是（ ）。",[97,99,101,103],{"key":20,"text":98,"correct":22},"设有电影院的人防工程，当底层室内地面与室外出入口地坪高差大于10m时，应设置防烟楼梯间",{"key":24,"text":100,"correct":22},"设有建筑面积大于1000m2的商场的人防工程，当地下为两层，且地下第二层的室内地面与室外出入口地坪高差不大于10m时，应设置封闭楼梯间",{"key":28,"text":102,"correct":26},"设有建筑面积大于500m2的展览厅的人防工程，当底层室内地面与室外出入口地坪高差大于10m时，应设置防烟楼梯间",{"key":31,"text":104,"correct":22},"设有礼堂的人防工程，当地下为两层，且地下第二层的室内地面与室外出入口地坪高差不大于10m时，应设置封闭楼梯间",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":24,"analysis":33},934064,"下列关于人防工程内防烟分区划分的说法中，错误的是（ ）。",[109,111,113,115],{"key":20,"text":110,"correct":22},"室内地面至顶棚或顶板的高度在6m以上的场所，当划分防烟分区时，建筑面积不限",{"key":24,"text":112,"correct":26},"每个防烟分区的建筑面积不宜大于1000m2，当设置自动喷水灭火系统时也不应增加",{"key":28,"text":114,"correct":22},"防烟分区不应跨越防火分区",{"key":31,"text":116,"correct":22},"可采用挡烟垂壁、隔墙或从顶棚突出不小于0．50m的梁划分防烟分区",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":28,"analysis":33},934065,"人防工程内不得使用和储存闪点（ ）的液体燃料。",[121,123,125,127],{"key":20,"text":122,"correct":22},"小于28℃",{"key":24,"text":124,"correct":22},"大于或等于28℃",{"key":28,"text":126,"correct":26},"小于60℃",{"key":31,"text":128,"correct":22},"大于或等于60℃",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":20,"analysis":33},934066,"某地下商场的总建筑面积为 10000 ㎡,采用一个下沉式广场将商场分隔为 A,B,C 三个独立的区域。下列关于该下沉式广场的设计中,错误是（ ）。",[133,135,137,139],{"key":20,"text":134,"correct":26},"直通地面的疏散楼梯不应少于 2 部",{"key":24,"text":136,"correct":22},"A 区域通向下沉式广场的开口与 B 区域通向下沉式广场的开口最近边缘之间的水平距离为16m",{"key":28,"text":138,"correct":22},"下沉式广场的室外开敞空间中用于疏散的净面积为 172 ㎡",{"key":31,"text":140,"correct":22},"疏散楼梯的总宽度不应小于相邻最大防火分区通向下沉式广场计算疏散总宽度",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":28,"analysis":33},934067,"下列场所中，不应设置在人防工程内的是（ ）。",[145,147,149,151],{"key":20,"text":146,"correct":22},"医院病房",{"key":24,"text":148,"correct":22},"消防控制室",{"key":28,"text":150,"correct":26},"幼儿园",{"key":31,"text":152,"correct":22},"KTV",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":31,"analysis":33},934068,"某地下人防工程，地下一层室内地面与室外出入口地坪高差为12m，下列场所中，可设置在人防工程地下一层的是（ ）。",[157,159,161,162],{"key":20,"text":158,"correct":22},"放映厅",{"key":24,"text":160,"correct":22},"夜总会",{"key":28,"text":146,"correct":22},{"key":31,"text":148,"correct":26},{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":165,"options":166,"answer":31,"analysis":33},934069,"下列有关人防工程防火分区划分的说法中，错误的是（ ）。",[167,169,171,173],{"key":20,"text":168,"correct":22},"当采用防火墙确有困难时，可采用防火卷帘等防火分隔设施分隔",{"key":24,"text":170,"correct":22},"水泵房、污水泵房、水池、厕所、盥洗间等无可燃物的房间，其面积可不计人防火分区的面积之内",{"key":28,"text":172,"correct":22},"与柴油发电机配套的储油间，应与柴油发电机一起划分为一个防火分区",{"key":31,"text":174,"correct":26},"人防工程内的旅店、病房和宿舍可与其他区域划分为一个防火分区，但其疏散楼梯应独立设置",{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":28,"analysis":33},934070,"下列关于人防工程内丙、丁、戊类库房的防火分区划分的说法中，正确的是（ ）。",[179,181,183,185],{"key":20,"text":180,"correct":22},"当设置自动喷水灭火系统时，允许最大建筑面积可增加1倍",{"key":24,"text":182,"correct":22},"当设置火灾自动报警系统时，允许最大建筑面积可增加1倍",{"key":28,"text":184,"correct":26},"当设置火灾自动报警系统和自动喷水灭火系统时，允许最大建筑面积可增加1倍",{"key":31,"text":186,"correct":22},"当局部设置火灾自动报警系统时，增加的面积可按局部面积的1倍计算",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":24,"analysis":33},934071,"下列关于人防工程室内消防给水管道的说法中，错误的是（ ）。",[191,193,195,197],{"key":20,"text":192,"correct":22},"室内消防给水管道宜与其他用水管道分开设置",{"key":24,"text":194,"correct":26},"室内消火栓总数大于8个时，其给水管道应布置成环状",{"key":28,"text":196,"correct":22},"同层的室内消防给水管道，应采用阀门分成若干独立段，当某段损坏时，停止使用的消火栓数不应大于5个",{"key":31,"text":198,"correct":22},"室内消火栓给水管道应与自动喷水灭火系统的给水管道分开独立设置",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":28,"analysis":33},934072,"人防工程每个防火分区的允许最大建筑面积，除另有规定者外，不应大于（ ）m2。",[203,205,207,209],{"key":20,"text":204,"correct":22},"150",{"key":24,"text":206,"correct":22},"300",{"key":28,"text":208,"correct":26},"500",{"key":31,"text":210,"correct":22},"1000",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":24,"analysis":33},934073,"某电影院设置在人防工程的地下一层，建筑面积为1500m2，建筑内全部设置自动喷水灭火系统和火灾自动报警系统，并采用不燃或难燃装修材料装修，该电影院至少应划分为（）个防火分区。",[215,217,219,220],{"key":20,"text":216,"correct":22},"1",{"key":24,"text":218,"correct":26},"2",{"key":28,"text":39,"correct":22},{"key":31,"text":221,"correct":22},"4",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":20,"analysis":33},934074,"商业营业厅、展览厅等，当设置有火灾自动报警系统和自动灭火系统，且采用（ ）级装修材料装修时，防火分区允许最大建筑面积不应大于2000m2。",[226,227,229,231],{"key":20,"text":20,"correct":26},{"key":24,"text":228,"correct":22},"B1",{"key":28,"text":230,"correct":22},"B2",{"key":31,"text":232,"correct":22},"B3",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":20,"analysis":33},934075,"下列关于人防工程地下商店说法错误的是（ ）。",[237,239,241,243],{"key":20,"text":238,"correct":26},"地下一层商店售卖的商品中包括漆布",{"key":24,"text":240,"correct":22},"营业厅布置在地下二层",{"key":28,"text":242,"correct":22},"总建筑面积大于20000m2的地下一层采用防火墙进行分隔",{"key":31,"text":244,"correct":22},"地下一层相邻区域确需局部连通时，采取防火隔间进行分隔",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":24,"analysis":33},934076,"人防工程内设置有旅店、病房、员工宿舍时，不得设置在地下（ ）及以下层，并应划分为独立的防火分区，其疏散楼梯不得与其他防火分区的疏散楼梯共用。",[249,251,253,255],{"key":20,"text":250,"correct":22},"一层",{"key":24,"text":252,"correct":26},"二层",{"key":28,"text":254,"correct":22},"三层",{"key":31,"text":256,"correct":22},"四层",{"id":258,"libraryId":5,"type":259,"typeLabel":260,"stem":261,"options":262,"answer":273,"analysis":33},934077,2,"多选题","下列设置在人防工程内的场所中，疏散门应采用乙级防火门的是（ ）。",[263,265,267,268,270],{"key":20,"text":264,"correct":26},"游戏厅",{"key":24,"text":266,"correct":26},"厨房",{"key":28,"text":148,"correct":22},{"key":31,"text":269,"correct":22},"通信机房",{"key":271,"text":272,"correct":26},"E","食品加工房","ABE",{"id":275,"libraryId":5,"type":259,"typeLabel":260,"stem":276,"options":277,"answer":288,"analysis":33},934078,"关于人防工程内的防火分隔要求，下列说法正确的是（ ）。",[278,280,282,284,286],{"key":20,"text":279,"correct":26},"电影院的观众厅与舞台之间的墙耐火极限不应低于2．50h",{"key":24,"text":281,"correct":26},"消防控制室应采用耐火极限不低于2．00h的隔墙和1．50h的楼板与其他场所隔开，墙上应设置常闭的甲级防火门",{"key":28,"text":283,"correct":26},"柴油发电机房的储油间，墙上应设置常闭的甲级防火门",{"key":31,"text":285,"correct":22},"同一防火分区内厨房、食品加工等用火用电用气场所，墙上应设置不低于甲级的防火门",{"key":271,"text":287,"correct":22},"歌舞娱乐放映游艺场所，一个厅、室的建筑面积不应大于200m2，且应采用耐火极限不低于2．00h的隔墙和1．00h的楼板与其他场所隔开","ABC",{"id":290,"libraryId":5,"type":259,"typeLabel":260,"stem":291,"options":292,"answer":303,"analysis":33},934079,"消防安全管理水平的评估主要包含（ ）。",[293,295,297,299,301],{"key":20,"text":294,"correct":26},"消防管理制度评估",{"key":24,"text":296,"correct":22},"消防人员素质评估",{"key":28,"text":298,"correct":26},"火灾应急救援预案评估",{"key":31,"text":300,"correct":22},"消除火灾发生评估",{"key":271,"text":302,"correct":26},"消防演练计划评估","ACE",{"id":305,"libraryId":5,"type":259,"typeLabel":260,"stem":306,"options":307,"answer":318,"analysis":33},934080,"火灾风险评估按照建筑所处状态可分为（ ）。",[308,310,312,314,316],{"key":20,"text":309,"correct":26},"预先评估",{"key":24,"text":311,"correct":26},"现状评估",{"key":28,"text":313,"correct":22},"事后评估",{"key":31,"text":315,"correct":22},"临时评估",{"key":271,"text":317,"correct":22},"专项评估","AB",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":28,"analysis":33},934081,"下列火灾风险评估的分类中，不属于按照指标处理方式分类的是（ ）。",[323,325,327,329],{"key":20,"text":324,"correct":22},"定性评估",{"key":24,"text":326,"correct":22},"半定量评估",{"key":28,"text":328,"correct":26},"半定性评估",{"key":31,"text":330,"correct":22},"定量评估",{"id":332,"libraryId":5,"type":15,"typeLabel":16,"stem":333,"options":334,"answer":31,"analysis":33},934082,"风险评估的步骤不包括（ ）。",[335,337,339,341],{"key":20,"text":336,"correct":22},"风险识别",{"key":24,"text":338,"correct":22},"风险分析",{"key":28,"text":340,"correct":22},"风险评价",{"key":31,"text":342,"correct":26},"风险应对",{"id":344,"libraryId":5,"type":15,"typeLabel":16,"stem":345,"options":346,"answer":24,"analysis":33},934083,"依靠人的观察分析能力，借助经验和判断能力进行评估指的是（ ）。",[347,348,349,350],{"key":20,"text":309,"correct":22},{"key":24,"text":324,"correct":26},{"key":28,"text":311,"correct":22},{"key":31,"text":330,"correct":22},{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":20,"analysis":33},934084,"在风险评估过程中，将风险分析的结果与组织的风险准则比较指的是（ ）。",[355,356,357,358],{"key":20,"text":340,"correct":26},{"key":24,"text":338,"correct":22},{"key":28,"text":342,"correct":22},{"key":31,"text":336,"correct":22},{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":31,"analysis":33},934085,"风险管理过程是组织管理的有机组成部分，嵌入组织文化和实践当中，贯穿于组织的整个经营过程。风险管理过程包括（ ）、风险评估、风险应对、监督和检查。",[363,365,367,369],{"key":20,"text":364,"correct":22},"环境依赖",{"key":24,"text":366,"correct":22},"持续改进",{"key":28,"text":368,"correct":22},"创造价值",{"key":31,"text":370,"correct":26},"明确环境信息",{"id":372,"libraryId":5,"type":15,"typeLabel":16,"stem":373,"options":374,"answer":24,"analysis":33},934086,"贯穿于风险管理全过程的是（ ）。",[375,377,379,380],{"key":20,"text":376,"correct":22},"风险评估",{"key":24,"text":378,"correct":26},"沟通与记录",{"key":28,"text":342,"correct":22},{"key":31,"text":370,"correct":22},{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":28,"analysis":33},934087,"下列不属于风险评估内容的是（ ）。",[385,386,387,388],{"key":20,"text":336,"correct":22},{"key":24,"text":338,"correct":22},{"key":28,"text":342,"correct":26},{"key":31,"text":340,"correct":22},{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":24,"analysis":33},934088,"（ ）是在建筑（区域）建设工程已经竣工，即将投入运行前或已经投入运行时所处的阶段进行的风险评估，用于了解建筑（区域）的现实风险，以采取降低风险的措施。",[393,394,395,396],{"key":20,"text":309,"correct":22},{"key":24,"text":311,"correct":26},{"key":28,"text":324,"correct":22},{"key":31,"text":330,"correct":22},{"id":398,"libraryId":5,"type":259,"typeLabel":260,"stem":399,"options":400,"answer":406,"analysis":33},934089,"根据建筑所处的不同状态，可以将火灾风险评估分为（ ）。",[401,402,403,404,405],{"key":20,"text":309,"correct":26},{"key":24,"text":324,"correct":22},{"key":28,"text":311,"correct":26},{"key":31,"text":330,"correct":22},{"key":271,"text":326,"correct":22},"AC",{"id":408,"libraryId":5,"type":259,"typeLabel":260,"stem":409,"options":410,"answer":418,"analysis":33},934090,"风险管理的过程主要包括（ ）以及沟通和记录等。",[411,413,414,415,416],{"key":20,"text":412,"correct":22},"管理资料收集",{"key":24,"text":370,"correct":26},{"key":28,"text":376,"correct":26},{"key":31,"text":342,"correct":26},{"key":271,"text":417,"correct":26},"监督和检查","BCDE",{"id":420,"libraryId":5,"type":15,"typeLabel":16,"stem":421,"options":422,"answer":31,"analysis":33},934091,"下列有关火灾危险源与火灾风险源的说法，不正确的是（ ）。",[423,425,427,429],{"key":20,"text":424,"correct":22},"第一类危险源的存在是事故发生的前提",{"key":24,"text":426,"correct":22},"第一类危险源决定着事故后果的严重程度",{"key":28,"text":428,"correct":22},"第二类危险源出现的难易决定事故发生的可能性大小",{"key":31,"text":430,"correct":26},"危险源来自于实践的需要，而风险源则来自于理论上的定义",{"id":432,"libraryId":5,"type":15,"typeLabel":16,"stem":433,"options":434,"answer":24,"analysis":33},934092,"下列属于主动防火措施的是（ ）。",[435,437,439,441],{"key":20,"text":436,"correct":22},"防火间距",{"key":24,"text":438,"correct":26},"灭火器材",{"key":28,"text":440,"correct":22},"防火分区",{"key":31,"text":442,"correct":22},"消防扑救条件",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":28,"analysis":33},934093,"在建筑防火中，防火卷帘属于（ ）。",[447,448,450,452],{"key":20,"text":440,"correct":22},{"key":24,"text":449,"correct":22},"疏散设施",{"key":28,"text":451,"correct":26},"防火分隔设施",{"key":31,"text":442,"correct":22},{"id":454,"libraryId":5,"type":15,"typeLabel":16,"stem":455,"options":456,"answer":31,"analysis":33},934094,"下列关于火灾危险、火灾危险性与火灾风险的说法，正确的是（ ）。",[457,459,461,463],{"key":20,"text":458,"correct":22},"危险表达的是某事物对人们构成的不良影响或后果等，强调的是主体",{"key":24,"text":460,"correct":22},"风险表达的是人们采取了某种行动后可能面临的有害后果，强调的是客体",{"key":28,"text":462,"correct":22},"火灾风险的大小通常用火灾发生的几率除以火灾后果的期望值来衡量",{"key":31,"text":464,"correct":26},"火灾危险是客观存在的随机现象",{"id":466,"libraryId":5,"type":15,"typeLabel":16,"stem":467,"options":468,"answer":24,"analysis":33},934095,"评估建筑物或活动场地内的人员能否安全疏散，要考虑建筑物或活动场地内人员自身的一些特点对安全疏散的影响，主要表现在人员荷载、人员素质、（ ）和人员体质几个方面。",[469,471,473,475],{"key":20,"text":470,"correct":22},"人员关系",{"key":24,"text":472,"correct":26},"人员熟知度",{"key":28,"text":474,"correct":22},"人员年龄",{"key":31,"text":476,"correct":22},"人员密度",{"id":478,"libraryId":5,"type":15,"typeLabel":16,"stem":479,"options":480,"answer":24,"analysis":33},934096,"导致约束、限制能量屏蔽措施失效或破坏的各种不安全因素是指（ ）。",[481,483,485,487],{"key":20,"text":482,"correct":22},"第一类危险源",{"key":24,"text":484,"correct":26},"第二类危险源",{"key":28,"text":486,"correct":22},"第三类危险源",{"key":31,"text":488,"correct":22},"第四类危险源",{"id":490,"libraryId":5,"type":15,"typeLabel":16,"stem":491,"options":492,"answer":20,"analysis":33},934098,"火灾隐患首先是一种（ ）。",[493,495,497,499],{"key":20,"text":494,"correct":26},"违反法律法规的行为",{"key":24,"text":496,"correct":22},"忽视法律法规的行为",{"key":28,"text":498,"correct":22},"忽视人身财产安全的行为",{"key":31,"text":500,"correct":22},"违反道德观念的行为",{"id":502,"libraryId":5,"type":15,"typeLabel":16,"stem":503,"options":504,"answer":28,"analysis":33},934099,"产生能量的能量源或拥有能量的载体指的是（ ）。",[505,507,509,510],{"key":20,"text":506,"correct":22},"火灾隐患",{"key":24,"text":508,"correct":22},"火灾风险",{"key":28,"text":482,"correct":26},{"key":31,"text":484,"correct":22},{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":31,"analysis":33},934100,"依据危险源在事故发生、发展过程中的作用，下列属于第二类危险源的是（ ）。",[515,517,519,521],{"key":20,"text":516,"correct":22},"可燃物",{"key":24,"text":518,"correct":22},"火灾烟气",{"key":28,"text":520,"correct":22},"火灾中有毒气体",{"key":31,"text":522,"correct":26},"应急广播",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":20,"analysis":33},934101,"在消防工作对五个要素进行控制的过程中，人们最容易控制的要素是（ ）。",[527,529,531,533],{"key":20,"text":528,"correct":26},"引火源",{"key":24,"text":530,"correct":22},"助燃物",{"key":28,"text":532,"correct":22},"可燃剂",{"key":31,"text":534,"correct":22},"时间",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":24,"analysis":33},934102,"（ ）危险源是指导致约束、限制能量屏蔽措施失效或破坏的各种不安全因素。",[539,541,543,545],{"key":20,"text":540,"correct":22},"第一类",{"key":24,"text":542,"correct":26},"第二类",{"key":28,"text":544,"correct":22},"第三类",{"key":31,"text":546,"correct":22},"第四类",{"id":548,"libraryId":5,"type":259,"typeLabel":260,"stem":549,"options":550,"answer":561,"analysis":33},934103,"安全检查表的特点包括（ ）。",[551,553,555,557,559],{"key":20,"text":552,"correct":26},"有利于安全教育",{"key":24,"text":554,"correct":26},"有利于明确责任，避免在发生事故时责任纠缠不清",{"key":28,"text":556,"correct":22},"具有特殊性",{"key":31,"text":558,"correct":26},"可以随科学发展和标准规范的变化而不断完善",{"key":271,"text":560,"correct":26},"可以事先编制，集思广益","ABDE",{"id":563,"libraryId":5,"type":259,"typeLabel":260,"stem":564,"options":565,"answer":561,"analysis":33},934104,"事件树分析法是一种按事故发展的时间顺序，由初始事件开始推论可能的后果，从而进行危险源辨识的方法，事件树的编制程序包括（ ）。",[566,568,570,572,574],{"key":20,"text":567,"correct":26},"确定初始事件",{"key":24,"text":569,"correct":26},"判定安全功能",{"key":28,"text":571,"correct":22},"找出危险点",{"key":31,"text":573,"correct":26},"绘制事件树",{"key":271,"text":575,"correct":26},"简化事件树",{"id":577,"libraryId":5,"type":15,"typeLabel":16,"stem":578,"options":579,"answer":24,"analysis":33},934105,"在事故树中，引起顶事件发生的基本事件的集合称为（ ）。",[580,582,584,586],{"key":20,"text":581,"correct":22},"径集",{"key":24,"text":583,"correct":26},"割集",{"key":28,"text":585,"correct":22},"最小径集",{"key":31,"text":587,"correct":22},"最小割集",{"id":589,"libraryId":5,"type":15,"typeLabel":16,"stem":590,"options":591,"answer":20,"analysis":33},934106,"火灾风险评估的试验方法不包括（ ）。",[592,594,596,598],{"key":20,"text":593,"correct":26},"模拟实验",{"key":24,"text":595,"correct":22},"相似试验",{"key":28,"text":597,"correct":22},"实体试验",{"key":31,"text":599,"correct":22},"热烟试验",{"id":601,"libraryId":5,"type":15,"typeLabel":16,"stem":602,"options":603,"answer":31,"analysis":33},934107,"下列关于火灾风险评估的说法中，错误的是（ ）。",[604,606,608,610],{"key":20,"text":605,"correct":22},"事故连锁越多，系统越危险",{"key":24,"text":607,"correct":22},"事故连锁中事件越少，系统越危险",{"key":28,"text":609,"correct":22},"成功连锁越多，系统越安全",{"key":31,"text":611,"correct":26},"成功连锁中事件越少，系统越危险",[613,616,619,622,625,628],{"id":15,"name":614,"category":7,"favorite":615},"领导干部任职前廉政法规知识测试题",92,{"id":617,"name":618,"category":7,"favorite":15},595,"建筑结构与设备",{"id":620,"name":621,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":623,"name":624,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":626,"name":627,"category":7,"favorite":8},534,"BIM工程师",{"id":629,"name":627,"category":7,"favorite":8},535]