[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-47":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":646},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,47,50,2960,[13,34,46,58,70,82,94,106,118,130,142,160,174,186,198,210,222,234,246,257,269,281,293,305,317,329,341,353,368,380,392,404,416,428,443,458,472,487,501,515,529,541,553,565,577,589,601,613,625,634],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},934006,1,"单选题","洁净厂房每一生产层，每一防火分区或每一洁净区的安全出口数量不应少于2个。下列可设1个安全出口的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","对甲类生产厂房每层的洁净生产区总建筑面积不超过100m2，且同一时间内的生产人员总数不超过5人",true,{"key":24,"text":25,"correct":26},"B","对甲类生产厂房每层的洁净生产区总建筑面积不超过150m2，且同一时间内的生产人员总数不超过5人",false,{"key":28,"text":29,"correct":26},"C","对乙类生产厂房每层的洁净生产区总建筑面积不超过100m2，且同一时间内的生产人员总数不超过10人",{"key":31,"text":32,"correct":26},"D","对乙类生产厂房每层的洁净生产区总建筑面积不超过150m2，且同一时间内的生产人员总数不超过5人","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},934007,"洁净室的顶棚、壁板及夹芯材料应为不燃烧体，且不得采用有机复合材料。顶棚和壁板的耐火极限不应低于（ ）h。",[38,40,42,44],{"key":20,"text":39,"correct":22},"0．4",{"key":24,"text":41,"correct":26},"0．5",{"key":28,"text":43,"correct":26},"1．0",{"key":31,"text":45,"correct":26},"1．5",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},934008,"某胶片厂的洗印车间，采用单层厂房，耐火等级为一级。该车间内防火墙间最大允许占地面积为（ ）m2。",[50,52,54,56],{"key":20,"text":51,"correct":26},"2000",{"key":24,"text":53,"correct":22},"3000",{"key":28,"text":55,"correct":26},"4000",{"key":31,"text":57,"correct":26},"5000",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},934009,"洁净室的排风系统设计应符合的规定不包括（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"应防止室外气流倒灌",{"key":24,"text":65,"correct":26},"含有易燃、易爆物质的局部排风系统应按物理化学性质采取相应的防火防爆措施",{"key":28,"text":67,"correct":26},"排风介质中有害物浓度及排放速率超过国家或地区有害物排放浓度及排放速率规定时，应进行无害化处理",{"key":31,"text":69,"correct":22},"对含有水蒸气和凝结性物质的排风系统，不应设坡度及排放口",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},934010,"下列有关洁净厂房的说法中，不正确的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":26},"洁净厂房内应少设隔间",{"key":24,"text":77,"correct":26},"洁净厂房内不同生产火灾危险性区域应采取分隔措施",{"key":28,"text":79,"correct":26},"甲、乙类与非甲、乙类相邻的生产区段之间应采取分隔措施",{"key":31,"text":81,"correct":22},"空气洁净度等级相同的工序和工作室宜分散布置",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":28,"analysis":33},934011,"下列关于洁净厂房内洁净室装修材料的说法中，错误的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"洁净室的顶棚应为不燃烧体，且不得采用有机复合材料",{"key":24,"text":89,"correct":26},"洁净室的壁板及夹芯材料应为不燃烧体，且不得采用有机复合材料",{"key":28,"text":91,"correct":22},"顶棚和壁板的耐火极限不应低于0．50h",{"key":31,"text":93,"correct":26},"疏散走道顶棚的耐火极限不应低于1．00h",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":28,"analysis":33},934012,"下列关于洁净厂房安全疏散的说法中，错误的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"甲类生产厂房每层的洁净生产区总建筑面积不超过100㎡，且同一时间内的生产人员总数不超过5人时，可设置一个安全出口",{"key":24,"text":101,"correct":26},"乙类生产厂房每层的洁净生产区总建筑面积不超过100m2，且同一时间内的生产人员总数不超过5人时，可设置一个安全出口",{"key":28,"text":103,"correct":22},"洁净厂房专用消防口的宽度不应小于750mm，高度不应小于1800mm，并应有明显标志，楼层的专用消防口应设置阳台，并从首层开始向上层架设钢梯",{"key":31,"text":105,"correct":26},"洁净厂房同层洁净室（区）外墙应设可供消防人员通往厂房洁净室（区）的门窗，其门窗洞口间距大于80m时，应在该段外墙的适当部位设置专用消防口",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":31,"analysis":33},934013,"下列关于洁净厂房内静电防护措施及接地措施的说法中错误的是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":26},"洁净室的净化空调系统应采取防静电接地措施",{"key":24,"text":113,"correct":26},"在防静电接地系统各个连接部位之间电阻值应小于0．1Ω",{"key":28,"text":115,"correct":26},"接地系统采用综合接地方式时接地电阻值应小于或等于1Ω",{"key":31,"text":117,"correct":22},"选择分散接地方式时，各种功能接地系统的接地体必须远离防雷接地系统的接地体，两者应保持30m以上的间距",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":28,"analysis":33},934014,"某制药厂中的洁净厂区可设置为一个安全出口的为（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":26},"甲类生产厂房每层建筑面积为 80 ㎡，且同一时间内的生产人员总数为 6 人",{"key":24,"text":125,"correct":26},"乙类生产厂房每层建筑面积为 110 ㎡，且同一时间内的生产人员总数为 8 人",{"key":28,"text":127,"correct":22},"丙类生产厂房每层建筑面积为 220 ㎡，且同一时间内的生产人员总数为 15 人",{"key":31,"text":129,"correct":26},"地下厂房每层建筑面积为 48m2，且同一时间的作业人数为 10 人",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":20,"analysis":33},934015,"甲、乙类生产厂房每层的洁净区总建筑面积不超过100m2，且同一时间内的生产人员总数不超过5人的洁净厂房可以（ ）安全出口。",[134,136,138,140],{"key":20,"text":135,"correct":22},"设置1个",{"key":24,"text":137,"correct":26},"设置2个",{"key":28,"text":139,"correct":26},"设置3个",{"key":31,"text":141,"correct":26},"不设",{"id":143,"libraryId":5,"type":144,"typeLabel":145,"stem":146,"options":147,"answer":159,"analysis":33},934016,2,"多选题","下列关于信息机房的接地说法不正确的是（ ）。",[148,150,152,154,156],{"key":20,"text":149,"correct":26},"交流工作接地：接地电阻小于4Ω",{"key":24,"text":151,"correct":26},"直流工作接地：接地电阻小于1Ω",{"key":28,"text":153,"correct":22},"综合接地系统：接地电阻小于4Ω",{"key":31,"text":155,"correct":22},"防雷接地：接地电阻小于8Ω",{"key":157,"text":158,"correct":26},"E","机房活动地板下须设置静电泄漏洞","CD",{"id":161,"libraryId":5,"type":144,"typeLabel":145,"stem":162,"options":163,"answer":173,"analysis":33},934017,"下列符合信息机房接地电阻取值规定的有（ ）。",[164,166,168,169,171],{"key":20,"text":165,"correct":22},"不间断电源（UPS）输出零地电压应小于1V",{"key":24,"text":167,"correct":26},"安全保护接地电阻为8Ω",{"key":28,"text":158,"correct":22},{"key":31,"text":170,"correct":26},"接地体引出线横截面面积为10mm2",{"key":157,"text":172,"correct":22},"交流工作接地电阻小于4Ω","ACE",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":24,"analysis":33},934018,"下列关于数据中心主机房内通道与设备间的距离，不符合规范要求的是（ ）。",[178,180,182,184],{"key":20,"text":179,"correct":26},"用于搬运设备的通道净宽为1．5m",{"key":24,"text":181,"correct":22},"背对背布置的机柜（架）背面之间的距离为0．7m",{"key":28,"text":183,"correct":26},"面对面布置的机柜（架）正面之间的距离为1．2m",{"key":31,"text":185,"correct":26},"成行排列的机柜（架），其长度为7m，两端设有通道",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":31,"analysis":33},934019,"下列关于数据中心建筑与结构的说法中错误的是（ ）。",[190,192,194,196],{"key":20,"text":191,"correct":26},"新建数据中心时，主机房净高不宜小于3．0m",{"key":24,"text":193,"correct":26},"变形缝不宜穿过主机房",{"key":28,"text":195,"correct":26},"数据中心内通道的宽度及门的尺寸应满足设备和材料的运输要求，建筑人口至主机房的通道净宽不应小于1．5m",{"key":31,"text":197,"correct":22},"主机房和辅助区不应布置在用水区域的直接上方",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":20,"analysis":33},934020,"当电子信息系统机房位于其他建筑物内时，在主机房与其他部位之间应设置耐火极限不低于2h的隔墙，隔墙上的门应采用（ ）。",[202,204,206,208],{"key":20,"text":203,"correct":22},"甲级防火门",{"key":24,"text":205,"correct":26},"乙级防火门",{"key":28,"text":207,"correct":26},"丙级防火门",{"key":31,"text":209,"correct":26},"防火卷帘",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":24,"analysis":33},934021,"当信息机房位于其他建筑物内时，在主机房与其他部位之间应设置耐火极限不低于（ ）h的隔墙。",[214,216,218,220],{"key":20,"text":215,"correct":26},"1",{"key":24,"text":217,"correct":22},"2",{"key":28,"text":219,"correct":26},"2．5",{"key":31,"text":221,"correct":26},"3",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":20,"analysis":33},934022,"信息机房主机房及基本工作间内当防护区个数大于8个时，为了经济实用，可采用（ ）或其他新型、环保的哈龙替代技术。",[226,228,230,232],{"key":20,"text":227,"correct":22},"细水雾灭火系统",{"key":24,"text":229,"correct":26},"IG—541灭火系统",{"key":28,"text":231,"correct":26},"二氧化碳灭火系统",{"key":31,"text":233,"correct":26},"自动喷水灭火系统",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":31,"analysis":33},934023,"信息机房内电气设备多，电气线路及机房信号线较多，为确保用电安全及数据传送安全，迅速而准确地探测出被保护区内发生火灾的部位，应在综合布线区、电缆井道、桥架处设置（ ）。",[238,240,242,244],{"key":20,"text":239,"correct":26},"空气采样烟雾报警器",{"key":24,"text":241,"correct":26},"分布式火灾探测器",{"key":28,"text":243,"correct":26},"分布式感烟光缆探测报警系统",{"key":31,"text":245,"correct":22},"分布式感温光缆温度探测报警系统",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":31,"analysis":33},934024,"主机房内的导体必须与大地做可靠的连接，其中防雷接地电阻应小于（ ）Ω。",[250,251,253,255],{"key":20,"text":215,"correct":26},{"key":24,"text":252,"correct":26},"4",{"key":28,"text":254,"correct":26},"5",{"key":31,"text":256,"correct":22},"10",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":20,"analysis":33},934025,"下列信息机房的设置，不符合规范要求的是（ ）。",[261,263,265,267],{"key":20,"text":262,"correct":22},"数据中心内放置计算机的机房不宜超过六层",{"key":24,"text":264,"correct":26},"信息机房的耐火等级不应低于二级",{"key":28,"text":266,"correct":26},"计算机房的室内装修均应采用不燃或难燃材料",{"key":31,"text":268,"correct":26},"面积为80m2的主机房，设置1个安全出口",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":28,"analysis":33},934026,"下列关于数据中心安全疏散的说法中，错误的是（ ）。",[273,275,277,279],{"key":20,"text":274,"correct":26},"当主机房设有高灵敏度的吸气式烟雾探测火灾报警系统时，主机房内任一点到最近安全出口的直线距离可增加50％",{"key":24,"text":276,"correct":26},"单层数据中心室内任一点至最近安全出口的直线距离不应大于80m",{"key":28,"text":278,"correct":22},"多层数据中心室内任一点至最近安全出口的直线距离不应大于70m",{"key":31,"text":280,"correct":26},"建筑面积不大于100m2的主机房可设置一个疏散门",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":20,"analysis":33},934027,"下列关于数据中心的说法中，错误的是（ ）。",[285,287,289,291],{"key":20,"text":286,"correct":22},"当数据中心位于其他建筑物内时，数据中心与建筑内其他功能用房之间应采用耐火极限不低于2．00h的防火隔墙和1．50h的楼板隔开，隔墙上开门应采用乙级防火门",{"key":24,"text":288,"correct":26},"建筑面积大于120m2的主机房，疏散门不应少于两个，且应分散布置",{"key":28,"text":290,"correct":26},"多层数据中心内直通疏散走道的房间疏散门至最近安全出口的直线距离当位于两个安全出口之间的疏散门时，不应大于40m",{"key":31,"text":292,"correct":26},"多层数据中心内直通疏散走道的房间疏散门至最近安全出口的直线距离当位于袋形走道两侧或尽端的疏散门时，不应大于22m",{"id":294,"libraryId":5,"type":15,"typeLabel":16,"stem":295,"options":296,"answer":24,"analysis":33},934028,"电子信息系统机房的耐火等级不应低于（ ）。",[297,299,301,303],{"key":20,"text":298,"correct":26},"一级",{"key":24,"text":300,"correct":22},"二级",{"key":28,"text":302,"correct":26},"三级",{"key":31,"text":304,"correct":26},"四级",{"id":306,"libraryId":5,"type":15,"typeLabel":16,"stem":307,"options":308,"answer":31,"analysis":33},934029,"下列数据中心为A级数据中心的是（ ）。",[309,311,313,315],{"key":20,"text":310,"correct":26},"电子信息系统运行中断将造成较大的经济损失",{"key":24,"text":312,"correct":26},"电子信息系统运行中断将造成公共场所秩序的混乱",{"key":28,"text":314,"correct":26},"电子信息系统运行中断将造成一般的经济损失",{"key":31,"text":316,"correct":22},"电子信息系统运行中断将造成公共场所秩序严重混乱",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":24,"analysis":33},934030,"数据中心的组成应根据系统运行特点及设备具体要求确定，宜由主机房、辅助区、支持区、（ ）等功能区组成。",[321,323,325,327],{"key":20,"text":322,"correct":26},"办公区",{"key":24,"text":324,"correct":22},"行政管理区",{"key":28,"text":326,"correct":26},"档案区",{"key":31,"text":328,"correct":26},"值班区",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":20,"analysis":33},934031,"数据中心用户工作室的使用面积可按（ ）计算。",[333,335,337,339],{"key":20,"text":334,"correct":22},"4m2／人～5m2／人",{"key":24,"text":336,"correct":26},"4m2／人～6m2／人",{"key":28,"text":338,"correct":26},"5m2／人～7m2／人",{"key":31,"text":340,"correct":26},"3m2／人～5m2／人",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":31,"analysis":33},934032,"下列关于数据中心灭火系统选择的说法中，错误的是（ ）。",[345,347,349,351],{"key":20,"text":346,"correct":26},"A级数据中心的主机房宜设置气体灭火系统",{"key":24,"text":348,"correct":26},"A级数据中心的主机房可设置细水雾灭火系统",{"key":28,"text":350,"correct":26},"B级数据中心的主机房可设置自动喷水灭火系统",{"key":31,"text":352,"correct":22},"总控中心等长期有人工作的区域应设置细水雾灭火系统",{"id":354,"libraryId":5,"type":144,"typeLabel":145,"stem":355,"options":356,"answer":367,"analysis":33},934033,"信息机房的火灾特点（ ）",[357,359,361,363,365],{"key":20,"text":358,"correct":22},"信息机房的火灾特点",{"key":24,"text":360,"correct":22},"用电量大，电气火灾多",{"key":28,"text":362,"correct":22},"无人值守，遇警处置慢",{"key":31,"text":364,"correct":22},"环境特殊，扑救难度大",{"key":157,"text":366,"correct":26},"设备精密，火灾损失较小","ABCD",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":28,"analysis":33},934034,"距离公安消防队较远、被列为全国重点文物保护单位的古建筑群的管理单位，应当建立（ ），承担本单位的火灾扑救工作。",[372,374,376,378],{"key":20,"text":373,"correct":26},"兼职消防队",{"key":24,"text":375,"correct":26},"社会消防队",{"key":28,"text":377,"correct":22},"专职消防队",{"key":31,"text":379,"correct":26},"义务消防队",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":31,"analysis":33},934035,"下列建筑中不属于我国古建筑按照建筑物的用途分类的是（ ）。",[384,386,388,390],{"key":20,"text":385,"correct":26},"宫殿建筑",{"key":24,"text":387,"correct":26},"宗教建筑",{"key":28,"text":389,"correct":26},"民居建筑",{"key":31,"text":391,"correct":22},"城池建筑",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":24,"analysis":33},934036,"下列不属于古建筑按照结构形式分类的是（ ）。",[396,398,400,402],{"key":20,"text":397,"correct":26},"抬梁式",{"key":24,"text":399,"correct":22},"木物架式",{"key":28,"text":401,"correct":26},"穿斗式",{"key":31,"text":403,"correct":26},"干阑式",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":24,"analysis":33},934038,"某寺庙在配置灭火器时，计算单元的最小需配灭火级别应比住宅建筑增加（ ）。",[408,410,412,414],{"key":20,"text":409,"correct":26},"100％",{"key":24,"text":411,"correct":22},"30％",{"key":28,"text":413,"correct":26},"20％",{"key":31,"text":415,"correct":26},"50％",{"id":417,"libraryId":5,"type":144,"typeLabel":145,"stem":418,"options":419,"answer":427,"analysis":33},934039,"古建筑按其结构形式可分为（ ）。",[420,421,422,424,425],{"key":20,"text":397,"correct":22},{"key":24,"text":401,"correct":22},{"key":28,"text":423,"correct":26},"木架式",{"key":31,"text":403,"correct":22},{"key":157,"text":426,"correct":26},"层叠式","ABD",{"id":429,"libraryId":5,"type":144,"typeLabel":145,"stem":430,"options":431,"answer":442,"analysis":33},934040,"下列场所中，不可设置在人防工程地下二层的是（ ）。",[432,434,436,438,440],{"key":20,"text":433,"correct":22},"医院病房",{"key":24,"text":435,"correct":22},"桑拿浴室",{"key":28,"text":437,"correct":26},"地下商店",{"key":31,"text":439,"correct":22},"网吧",{"key":157,"text":441,"correct":22},"旅店","ABDE",{"id":444,"libraryId":5,"type":144,"typeLabel":145,"stem":445,"options":446,"answer":457,"analysis":33},934041,"下列关于人防工程防火设计要求的说法，正确的是（ ）。",[447,449,451,453,455],{"key":20,"text":448,"correct":22},"人防工程内应采用防火墙划分防火分区，当采用防火墙确有困难时，可采用防火卷帘代替",{"key":24,"text":450,"correct":26},"人防工程内的旅馆与其他防火分区共用疏散楼梯时，可以设置在地下三层",{"key":28,"text":452,"correct":26},"人防工程内的电影院，当设有火灾自动报警系统和自动灭火系统时，防火分区的最大允许建筑面积不应大于2000m2",{"key":31,"text":454,"correct":22},"人防工程内的消防控制室，应采用耐火极限不低于2．0h的隔墙和1．5h的楼板与其他场所隔开",{"key":157,"text":456,"correct":26},"人防工程的耐火等级应不低于二级","AD",{"id":459,"libraryId":5,"type":144,"typeLabel":145,"stem":460,"options":461,"answer":159,"analysis":33},934042,"某商业建筑，建筑高度为23．3m，地上标准层每层划分为面积相近的2个防火分区，防火分隔部位的宽度为60m，该商业建筑的下列防火分隔做法中，正确的有（ ）。",[462,464,466,468,470],{"key":20,"text":463,"correct":26},"防火墙设置两个不可开启的乙级防火窗",{"key":24,"text":465,"correct":26},"防火墙上设置两樘常闭式乙级防火门",{"key":28,"text":467,"correct":22},"设置总宽度为18m、耐火极限为3．00h的特级防火卷帘",{"key":31,"text":469,"correct":22},"采用耐火极限为3．00h的不燃性墙体从楼地面基层隔断至梁或楼板地面基层",{"key":157,"text":471,"correct":26},"通风管道在穿越防火墙处设置一个排烟防火阀",{"id":473,"libraryId":5,"type":144,"typeLabel":145,"stem":474,"options":475,"answer":486,"analysis":33},934043,"符合人民防空工程防火分区安全出口规定的有（ ）。",[476,478,480,482,484],{"key":20,"text":477,"correct":26},"房间建筑面积不大于60m2，且经常停留人数不超过20人时，可设置一个疏散出口",{"key":24,"text":479,"correct":22},"建筑面积不大于200m2，且经常停留人数不超过3人的防火分区，可只设置一个通向相邻防火分区的防火门",{"key":28,"text":481,"correct":22},"防火分区建筑面积不大于1000m2的商业营业厅、展览厅等场所，设置通向室外、直通室外的疏散楼梯间或避难走道的安全出口个数不得少于一个",{"key":31,"text":483,"correct":26},"在一个防火分区内，设置通向室外、直通室外的疏散楼梯间或避难走道的安全出口宽度之和，不宜小于规范规定的安全出口总宽度的50％",{"key":157,"text":485,"correct":22},"防火分区建筑面积大于1000m2的商业营业厅、展览厅等场所，设置通向室外、直通室外的疏散楼梯间或避难走道的安全出口个数不得少于两个","BCE",{"id":488,"libraryId":5,"type":144,"typeLabel":145,"stem":489,"options":490,"answer":500,"analysis":33},934044,"人防工程内不应设置（ ）。",[491,493,494,496,498],{"key":20,"text":492,"correct":22},"哺乳室",{"key":24,"text":433,"correct":26},{"key":28,"text":495,"correct":22},"游乐厅",{"key":31,"text":497,"correct":22},"幼儿园",{"key":157,"text":499,"correct":26},"卡拉OK厅","ACD",{"id":502,"libraryId":5,"type":144,"typeLabel":145,"stem":503,"options":504,"answer":442,"analysis":33},934045,"人民防空工程也称为人防工程，是指为保障人民防空指挥、通信、掩蔽等需要而建造的防护建筑，其按构筑形式分为（ ）。",[505,507,509,511,513],{"key":20,"text":506,"correct":22},"地道工程",{"key":24,"text":508,"correct":22},"坑道工程",{"key":28,"text":510,"correct":26},"平战工程",{"key":31,"text":512,"correct":22},"单建掘开式工程",{"key":157,"text":514,"correct":22},"人民防空地下室",{"id":516,"libraryId":5,"type":144,"typeLabel":145,"stem":517,"options":518,"answer":528,"analysis":33},934046,"为减少火灾时喷水灭火对电气设备和贵重物品的水溃影响，人防工程中图书、资料、档案等特藏库房，重要通信机房和电子计算机机房，变配电室和其他特殊重要的设备房间应设置（ ）。",[519,521,523,524,526],{"key":20,"text":520,"correct":26},"固定式泡沫灭火系统",{"key":24,"text":522,"correct":22},"气体灭火系统",{"key":28,"text":227,"correct":22},{"key":31,"text":525,"correct":26},"半固定式泡沫灭火系统",{"key":157,"text":527,"correct":26},"移动式泡沫灭火系统","BC",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":31,"analysis":33},934047,"下列有关人防工程中水泵接合器和室外消火栓的说法中，不正确的是（ ）。",[533,535,537,539],{"key":20,"text":534,"correct":26},"当人防工程内消防用水总量大于10L／s时，应在人防工程外设置水泵接合器",{"key":24,"text":536,"correct":26},"每个水泵接合器和室外消火栓的流量应按10～15L／s计算",{"key":28,"text":538,"correct":26},"水泵接合器与室外消火栓的距离不应大于40m",{"key":31,"text":540,"correct":22},"水泵接合器距人防工程出入口不宜小于15m",{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":28,"analysis":33},934048,"下列人防工程消防电源及配电的说法中，正确的是（ ）。",[545,547,549,551],{"key":20,"text":546,"correct":26},"建筑面积为3000m2的人防工程应按一级负荷供电",{"key":24,"text":548,"correct":26},"建筑面积为5000m2的人防工程应按一级负荷供电",{"key":28,"text":550,"correct":22},"消防水泵的供电回路应引自专用消防配电柜或专用供电回路，其配电和控制线路宜按防火分区划分",{"key":31,"text":552,"correct":26},"消防用电设备的配电线路即使采用矿物类不燃性电缆时，也不应明敷设",{"id":554,"libraryId":5,"type":15,"typeLabel":16,"stem":555,"options":556,"answer":20,"analysis":33},934049,"人防工程内沿墙面设置的疏散标志距地面不应大于（ ）m，间距不应大于（ ）m。",[557,559,561,563],{"key":20,"text":558,"correct":22},"1，15",{"key":24,"text":560,"correct":26},"0．5，10",{"key":28,"text":562,"correct":26},"1，20",{"key":31,"text":564,"correct":26},"0．5，20",{"id":566,"libraryId":5,"type":15,"typeLabel":16,"stem":567,"options":568,"answer":28,"analysis":33},934050,"人民防空工程中的单建掘开式工程是单独建设的采用（ ）施工，且大部分结构处于原地表以下的工程。",[569,571,573,575],{"key":20,"text":570,"correct":26},"盾构法",{"key":24,"text":572,"correct":26},"盖挖法",{"key":28,"text":574,"correct":22},"明挖法",{"key":31,"text":576,"correct":26},"喷锚暗挖法",{"id":578,"libraryId":5,"type":15,"typeLabel":16,"stem":579,"options":580,"answer":31,"analysis":33},934051,"人防工程内不得使用和储存液化石油气、相对密度（与空气密度比值）大于或等于（ ）的可燃气体。",[581,583,585,587],{"key":20,"text":582,"correct":26},"0．35",{"key":24,"text":584,"correct":26},"0．55",{"key":28,"text":586,"correct":26},"0．6",{"key":31,"text":588,"correct":22},"0．75",{"id":590,"libraryId":5,"type":15,"typeLabel":16,"stem":591,"options":592,"answer":24,"analysis":33},934052,"人防工程每个防火分区的安全出口数量不应少于（ ）个。",[593,595,597,599],{"key":20,"text":594,"correct":26},"一",{"key":24,"text":596,"correct":22},"二",{"key":28,"text":598,"correct":26},"三",{"key":31,"text":600,"correct":26},"四",{"id":602,"libraryId":5,"type":15,"typeLabel":16,"stem":603,"options":604,"answer":24,"analysis":33},934053,"人防工程中设置自然排烟设施的场所，自然排烟口底部距室内地面不应小于（ ）。",[605,607,609,611],{"key":20,"text":606,"correct":26},"1m",{"key":24,"text":608,"correct":22},"2m",{"key":28,"text":610,"correct":26},"3m",{"key":31,"text":612,"correct":26},"4m",{"id":614,"libraryId":5,"type":15,"typeLabel":16,"stem":615,"options":616,"answer":20,"analysis":33},934054,"下列关于人防工程平面布置的说法，错误的是（）。",[617,619,621,623],{"key":20,"text":618,"correct":22},"人防工程内不得使用和储存相对密度（与空气密度比值）大于或等于0．70的可燃气体和闪点小于60℃的液体燃料",{"key":24,"text":620,"correct":26},"人防工程内的地下商店营业厅不应设置在地下三层及以下",{"key":28,"text":622,"correct":26},"医院病房设置在地下一层时，室内地面与室外出入口地坪高差不应大于10m",{"key":31,"text":624,"correct":26},"员工宿舍设置在地下一层时应划分为独立的防火分区",{"id":626,"libraryId":5,"type":15,"typeLabel":16,"stem":627,"options":628,"answer":24,"analysis":33},934055,"某人防工程内设有建筑面积为2100m2的宾馆，并设有自动喷水灭火系统，该宾馆应至少划分为（ ）个防火分区。",[629,630,631,632],{"key":20,"text":217,"correct":26},{"key":24,"text":221,"correct":22},{"key":28,"text":252,"correct":26},{"key":31,"text":633,"correct":26},"6",{"id":635,"libraryId":5,"type":15,"typeLabel":16,"stem":636,"options":637,"answer":28,"analysis":33},934056,"柴油发电机房的储油间应设置高（ ）mm的不燃烧、不渗漏的门槛，地面不得设置地漏。",[638,640,642,644],{"key":20,"text":639,"correct":26},"50",{"key":24,"text":641,"correct":26},"100",{"key":28,"text":643,"correct":22},"150",{"key":31,"text":645,"correct":26},"200",[647,650,653,656,659,662],{"id":15,"name":648,"category":7,"favorite":649},"领导干部任职前廉政法规知识测试题",92,{"id":651,"name":652,"category":7,"favorite":15},595,"建筑结构与设备",{"id":654,"name":655,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":657,"name":658,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":660,"name":661,"category":7,"favorite":8},534,"BIM工程师",{"id":663,"name":661,"category":7,"favorite":8},535]