[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-45":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":626},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,45,50,2960,[13,34,46,58,70,79,91,109,124,138,152,167,179,191,203,215,227,236,248,260,272,281,292,304,316,328,337,352,366,378,390,402,414,426,438,446,454,466,478,487,499,511,523,535,547,559,571,583,597,611],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},933905,1,"单选题","下列关于加油加气站的平面布置的说法，不正确的是（）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","在加油加气合建站内，宜将柴油罐布置在LPG储罐或CNG储气瓶（组）、LNG储罐与汽油罐之间",false,{"key":24,"text":25,"correct":26},"B","加油加气站内的爆炸危险区域，不应超出站区围墙和可用地界线2m范围",true,{"key":28,"text":29,"correct":22},"C","柴油尾气处理液加注设施不符合防爆要求的，应布置在爆炸危险区域之外，且与爆炸危险区域边界线的距离不应小于3m",{"key":31,"text":32,"correct":22},"D","柴油尾气处理液加注设施符合防爆要求的，在进行平面布置时可按加油机对待","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},933906,"加油站卸油时常见的事故不包括（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"油罐满溢",{"key":24,"text":41,"correct":22},"静电起火",{"key":28,"text":43,"correct":22},"油品滴漏",{"key":31,"text":45,"correct":26},"雷击",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},933907,"下列关于加油站区内停车位和道路的说法正确的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"站内车道或停车位宽度应按车辆类型确定",{"key":24,"text":53,"correct":22},"站内的道路转弯半径应按行驶车型确定，且不宜小于8m",{"key":28,"text":55,"correct":22},"站内停车位应为平坡，道路坡度不应大于6％，且宜坡向站外",{"key":31,"text":57,"correct":22},"加油加气作业区内的停车位和道路路面宜采用沥青路面",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},933908,"加油站站内的道路转弯半径应按行驶车型确定，且不宜小于（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"4m",{"key":24,"text":65,"correct":22},"6m",{"key":28,"text":67,"correct":26},"9m",{"key":31,"text":69,"correct":22},"10m",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},933909,"加油站卸油时可能发生的火灾不包括（ ）。",[74,75,77,78],{"key":20,"text":39,"correct":22},{"key":24,"text":76,"correct":26},"电气火灾",{"key":28,"text":41,"correct":22},{"key":31,"text":43,"correct":22},{"id":80,"libraryId":5,"type":15,"typeLabel":16,"stem":81,"options":82,"answer":28,"analysis":33},933910,"下列关于汽车加油加气站防雷防静电接地电阻说法错误的是（）。",[83,85,87,89],{"key":20,"text":84,"correct":22},"LPG储罐采用阴极保护防腐，接地电阻不应大于10Ω",{"key":24,"text":86,"correct":22},"地上或管沟敷设的油品的管道、LPG管道、LNG管道共用接地，接地电阻不应大于30Ω",{"key":28,"text":88,"correct":26},"电气系统的工作和保护接地电阻不大于10Ω",{"key":31,"text":90,"correct":22},"防静电接地装置不应大于100Ω",{"id":92,"libraryId":5,"type":93,"typeLabel":94,"stem":95,"options":96,"answer":108,"analysis":33},933911,2,"多选题","加油加气站的站址选择，应符合城乡规划、环境保护和防火安全的要求，并应选在交通便利的地方。在城市中心区不应建（ ）。",[97,99,101,103,105],{"key":20,"text":98,"correct":26},"一级加油站",{"key":24,"text":100,"correct":26},"一级加气站",{"key":28,"text":102,"correct":22},"二级加油加气合建站",{"key":31,"text":104,"correct":26},"CNG加气母站",{"key":106,"text":107,"correct":22},"E","二级加油站","ABD",{"id":110,"libraryId":5,"type":93,"typeLabel":94,"stem":111,"options":112,"answer":123,"analysis":33},933912,"变电站的主要火灾包括（ ）",[113,115,117,119,121],{"key":20,"text":114,"correct":26},"电力变压器火灾",{"key":24,"text":116,"correct":26},"油断路器火灾",{"key":28,"text":118,"correct":26},"电缆火灾",{"key":31,"text":120,"correct":26},"其他原因引发火灾",{"key":106,"text":122,"correct":22},"工作人员吸烟引发的火灾","ABCD",{"id":125,"libraryId":5,"type":93,"typeLabel":94,"stem":126,"options":127,"answer":108,"analysis":33},933913,"下列关于火力发电厂防火设计的描述中，正确的有（ ）。",[128,130,132,134,136],{"key":20,"text":129,"correct":26},"电子计算机室的墙面、顶棚装修应用A级材料",{"key":24,"text":131,"correct":26},"电子计算机室的机械排烟系统的排烟量可按房间换气次数每小时不小于6次计算",{"key":28,"text":133,"correct":22},"原煤仓宜采用组合分配气体灭火系统，灭火剂应200％备用",{"key":31,"text":135,"correct":26},"单机容量在25MW以上的火力发电厂应按Ⅰ级负荷供电",{"key":106,"text":137,"correct":22},"在主要通道地面上的应急照明照度不应低于5lx",{"id":139,"libraryId":5,"type":93,"typeLabel":94,"stem":140,"options":141,"answer":151,"analysis":33},933914,"火力发电厂运煤系统中除尘系统的风道与部件以及室内采暖系统的管道、管件及保温材料不应采用（ ）级材料。",[142,143,145,147,149],{"key":20,"text":20,"correct":22},{"key":24,"text":144,"correct":26},"B1",{"key":28,"text":146,"correct":26},"B2",{"key":31,"text":148,"correct":26},"B3",{"key":106,"text":150,"correct":26},"F","BCDE",{"id":153,"libraryId":5,"type":93,"typeLabel":94,"stem":154,"options":155,"answer":166,"analysis":33},933915,"消防控制设备对除湿式系统外的自动喷水和水喷雾灭火系统应当有（ ）等控制、显示功能。",[156,158,160,162,164],{"key":20,"text":157,"correct":26},"控制系统的启、停",{"key":24,"text":159,"correct":26},"显示消防水泵的工作、故障状态",{"key":28,"text":161,"correct":26},"显示水流指示器、安全信号阀的工作状态",{"key":31,"text":163,"correct":22},"末端试水出口压力",{"key":106,"text":165,"correct":26},"报警阀的工作状态","ABCE",{"id":168,"libraryId":5,"type":15,"typeLabel":16,"stem":169,"options":170,"answer":24,"analysis":33},933916,"变电站的地上层与地下室共用楼梯间时，应在地上首层采用耐火极限不低于2h的不燃烧体隔墙和（ ）级防火门将地下或半地下部分与地上部分的连通部分完全隔开，并应有明显标志。",[171,173,175,177],{"key":20,"text":172,"correct":22},"甲",{"key":24,"text":174,"correct":26},"乙",{"key":28,"text":176,"correct":22},"丙",{"key":31,"text":178,"correct":22},"丁",{"id":180,"libraryId":5,"type":15,"typeLabel":16,"stem":181,"options":182,"answer":20,"analysis":33},933917,"不符合火力发电厂耐火构造设计要求的是（ ）。",[183,185,187,189],{"key":20,"text":184,"correct":26},"管道井、电缆井、排气道、垃圾道等竖向管井必须独立建造，其井壁应为耐火极限不低于0．75h的不燃烧体",{"key":24,"text":186,"correct":22},"建筑构件允许采用难燃烧材料（难燃烧体），但耐火极限不应低于0．75h",{"key":28,"text":188,"correct":22},"火力发电厂主厂房（包括汽轮发电机房、除氧间、煤仓间和锅炉房），其生产过程中的火灾危险性为丁级，要求厂房的建筑构件的耐火等级为二级",{"key":31,"text":190,"correct":22},"对钢结构，在容易发生火灾的部位需采取必要的防火保护措施，以达到防火要求",{"id":192,"libraryId":5,"type":15,"typeLabel":16,"stem":193,"options":194,"answer":24,"analysis":33},933918,"火力发电厂主控制楼、配电装置楼各层及电缆夹层的安全出口不应少于 （ ）个。",[195,197,199,201],{"key":20,"text":196,"correct":22},"一",{"key":24,"text":198,"correct":26},"二",{"key":28,"text":200,"correct":22},"三",{"key":31,"text":202,"correct":22},"四",{"id":204,"libraryId":5,"type":15,"typeLabel":16,"stem":205,"options":206,"answer":24,"analysis":33},933919,"我国的发电厂主要是（ ）发电厂。",[207,209,211,213],{"key":20,"text":208,"correct":22},"水力",{"key":24,"text":210,"correct":26},"燃煤机组火力",{"key":28,"text":212,"correct":22},"太阳能",{"key":31,"text":214,"correct":22},"核电",{"id":216,"libraryId":5,"type":15,"typeLabel":16,"stem":217,"options":218,"answer":31,"analysis":33},933920,"电缆从室外进入室内的入口处、电缆竖井的出入口处、电缆接头处、主控制室与电缆夹层之间以及长度超过（ ）m的电缆沟或电缆隧道，均应采取防止电缆火灾蔓延的阻燃或分隔措施。",[219,221,223,225],{"key":20,"text":220,"correct":22},"50",{"key":24,"text":222,"correct":22},"60",{"key":28,"text":224,"correct":22},"80",{"key":31,"text":226,"correct":26},"100",{"id":228,"libraryId":5,"type":15,"typeLabel":16,"stem":229,"options":230,"answer":28,"analysis":33},933921,"总油量超过（ ）kg的室内油浸变压器，应设置单独的变压器室。",[231,232,233,234],{"key":20,"text":220,"correct":22},{"key":24,"text":224,"correct":22},{"key":28,"text":226,"correct":26},{"key":31,"text":235,"correct":22},"150",{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":238,"options":239,"answer":28,"analysis":33},933922,"根据《火力发电厂与变电站设计防火规范》规定，变电站消防给水量应按（）计算。",[240,242,244,246],{"key":20,"text":241,"correct":22},"火灾时室内最大用水量",{"key":24,"text":243,"correct":22},"火灾时室外最大消防用水量",{"key":28,"text":245,"correct":26},"火灾时一次最大室内和室外消防用水量之和",{"key":31,"text":247,"correct":22},"火灾时二次最大室内和室外消防用水量之和",{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":31,"analysis":33},933923,"设置自动灭火系统的地下变电站每个防火分区的建筑面积不应大于（ ）m2。",[252,254,256,258],{"key":20,"text":253,"correct":22},"500",{"key":24,"text":255,"correct":22},"1000",{"key":28,"text":257,"correct":22},"1500",{"key":31,"text":259,"correct":26},"2000",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":28,"analysis":33},933924,"下列不属于火力发电厂火灾危险性的是（ ）。",[264,266,268,270],{"key":20,"text":265,"correct":22},"煤的自燃",{"key":24,"text":267,"correct":22},"锅炉爆炸",{"key":28,"text":269,"correct":26},"液氧泄漏",{"key":31,"text":271,"correct":22},"油料泄漏",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":28,"analysis":33},933925,"燃煤电厂主厂房的火灾危险性为（ ）类。",[276,277,278,279],{"key":20,"text":174,"correct":22},{"key":24,"text":176,"correct":22},{"key":28,"text":178,"correct":26},{"key":31,"text":280,"correct":22},"戊",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":31,"analysis":33},933926,"燃煤电厂锅炉房内最远工作地点到外部出口或楼梯的距离不应超过（ ）m。",[285,287,288,290],{"key":20,"text":286,"correct":22},"35",{"key":24,"text":220,"correct":22},{"key":28,"text":289,"correct":22},"45",{"key":31,"text":291,"correct":26},"75",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":31,"analysis":33},933927,"某200MW燃煤电厂，有4台50MW发电机组，则发电机组应划分成（ ）个报警区域。",[296,298,300,302],{"key":20,"text":297,"correct":22},"1",{"key":24,"text":299,"correct":22},"2",{"key":28,"text":301,"correct":22},"3",{"key":31,"text":303,"correct":26},"4",{"id":305,"libraryId":5,"type":15,"typeLabel":16,"stem":306,"options":307,"answer":28,"analysis":33},933928,"火力发电厂主厂房生产过程中的火灾危险性为（ ），要求厂房的建筑构件的耐火等级为（ ）。",[308,310,312,314],{"key":20,"text":309,"correct":22},"甲级，一级",{"key":24,"text":311,"correct":22},"乙级，二级",{"key":28,"text":313,"correct":26},"丁级，二级",{"key":31,"text":315,"correct":22},"丙级，一级",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":31,"analysis":33},933929,"火力发电厂总平面设计的关键在于（ ）。",[320,322,324,326],{"key":20,"text":321,"correct":22},"合理进行总体规划布局",{"key":24,"text":323,"correct":22},"采取针对性的防火技术措施",{"key":28,"text":325,"correct":22},"配置有效的消防设施",{"key":31,"text":327,"correct":26},"合理划定重点防火区域",{"id":329,"libraryId":5,"type":15,"typeLabel":16,"stem":330,"options":331,"answer":20,"analysis":33},933930,"燃煤电厂人员疏散用的应急照明，在主要通道地面上的最低照度值，不应低于（ ）lx。",[332,333,335,336],{"key":20,"text":297,"correct":26},{"key":24,"text":334,"correct":22},"1．5",{"key":28,"text":299,"correct":22},{"key":31,"text":301,"correct":22},{"id":338,"libraryId":5,"type":93,"typeLabel":94,"stem":339,"options":340,"answer":351,"analysis":33},933931,"下列飞机库中，其消防电源负荷等级应采用一级的是（ ）。",[341,343,345,347,349],{"key":20,"text":342,"correct":26},"Ⅰ类飞机库",{"key":24,"text":344,"correct":26},"Ⅱ类飞机库",{"key":28,"text":346,"correct":22},"Ⅲ类飞机库",{"key":31,"text":348,"correct":22},"Ⅳ类飞机库",{"key":106,"text":350,"correct":22},"Ⅴ类飞机库","AB",{"id":353,"libraryId":5,"type":93,"typeLabel":94,"stem":354,"options":355,"answer":123,"analysis":33},933932,"飞机库的火灾危险性主要表现在（ ）",[356,358,360,362,364],{"key":20,"text":357,"correct":26},"燃油流散遇火源引发火灾",{"key":24,"text":359,"correct":26},"清洗飞机座舱引发火灾",{"key":28,"text":361,"correct":26},"电气系统弓|发火灾",{"key":31,"text":363,"correct":26},"静电引发火灾",{"key":106,"text":365,"correct":22},"液氨泄漏",{"id":367,"libraryId":5,"type":15,"typeLabel":16,"stem":368,"options":369,"answer":28,"analysis":33},933933,"关于飞机库耐火等级和防火分区的说法，正确的是（ ）。",[370,372,374,376],{"key":20,"text":371,"correct":22},"Ⅲ类飞机库内飞机停放和维修区的防火分区最大允许建筑面积不应大于5000m2",{"key":24,"text":373,"correct":22},"Ⅰ类、Ⅱ类飞机库的耐火等级不应低于二级",{"key":28,"text":375,"correct":26},"飞机库建筑构件的燃烧性能均应为不燃烧性",{"key":31,"text":377,"correct":22},"飞机停放和维修区屋顶金属承重构件即使采用自动喷水灭火系统保护后，屋顶也仍应采用相应的措施进行防火保护",{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":28,"analysis":33},933934,"某飞机库为Ⅱ类飞机库，下列关于该飞机库消防车道的说法，错误的是（ ）。",[382,384,386,388],{"key":20,"text":383,"correct":22},"不能沿飞机库的两个长边设置消防车道",{"key":24,"text":385,"correct":22},"消防车道的净宽度不应小于6．0m",{"key":28,"text":387,"correct":26},"飞机库的长边长度不应大于220m",{"key":31,"text":389,"correct":22},"应设置环形消防车道",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":20,"analysis":33},933935,"下列关于飞机库设置自动喷水灭火系统的说法，不正确的是（ ）。",[394,396,398,400],{"key":20,"text":395,"correct":26},"飞机库大厅自动喷水灭火系统宜采用干式或预作用灭火系统",{"key":24,"text":397,"correct":22},"飞机库飞机停放区和维修区设置的自动喷水灭火系统的设计喷水强度不应小于7．0L／（minm2）",{"key":28,"text":399,"correct":22},"自动喷水灭火系统的连续供水时间不应小于45min",{"key":31,"text":401,"correct":22},"Ⅱ类飞机库设置自动喷水灭火系统时，系统作用面积不应小于480m2",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":20,"analysis":33},933936,"下列关于飞机库内供配电说法不正确的是（ ）。",[406,408,410,412],{"key":20,"text":407,"correct":26},"Ⅰ、Ⅱ类飞机库的消防电源负荷等级不应低于二级",{"key":24,"text":409,"correct":22},"当飞机库设有变电所时、消防用电的正常电源宜单独引自变电所",{"key":28,"text":411,"correct":22},"当电线、电缆成束集中敷设时，应采用阻燃型铜芯电线、电缆",{"key":31,"text":413,"correct":22},"飞机停放和维修区内电源插座距离地面的安装高度不应小于1．0m",{"id":415,"libraryId":5,"type":15,"typeLabel":16,"stem":416,"options":417,"answer":20,"analysis":33},933937,"一般情况下，两座相邻飞机库之间的防火间距不应小于（ ）m。但当两座飞机库其相邻的较高一面的外墙为防火墙时，其防火间距不限。",[418,420,422,424],{"key":20,"text":419,"correct":26},"13",{"key":24,"text":421,"correct":22},"14",{"key":28,"text":423,"correct":22},"16",{"key":31,"text":425,"correct":22},"30",{"id":427,"libraryId":5,"type":15,"typeLabel":16,"stem":428,"options":429,"answer":28,"analysis":33},933938,"Ⅰ类飞机库是指飞机停放和维修区内一个防火分区的建筑面积为（ ）的飞机库。",[430,432,434,436],{"key":20,"text":431,"correct":22},"1000～3000m2",{"key":24,"text":433,"correct":22},"3001～5000m2",{"key":28,"text":435,"correct":26},"5001～50000m2",{"key":31,"text":437,"correct":22},"50001～100000m2",{"id":439,"libraryId":5,"type":15,"typeLabel":16,"stem":440,"options":441,"answer":31,"analysis":33},933939,"飞机库的每个防火分区至少应有两个直通室外的安全出口，其最远工作地点到安全出口的距离不应大于（ ）m。",[442,443,444,445],{"key":20,"text":425,"correct":22},{"key":24,"text":289,"correct":22},{"key":28,"text":222,"correct":22},{"key":31,"text":291,"correct":26},{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":20,"analysis":33},933940,"飞机库应采用防火墙与办公楼、飞机部件喷漆间、飞机座椅维修间、航材库、配电室和动力站等生产辅助用房隔开，防火墙上的门窗应采用（ ）级防火门窗，或耐火极限不低于3．00h的防火卷帘。",[450,451,452,453],{"key":20,"text":172,"correct":26},{"key":24,"text":174,"correct":22},{"key":28,"text":176,"correct":22},{"key":31,"text":178,"correct":22},{"id":455,"libraryId":5,"type":15,"typeLabel":16,"stem":456,"options":457,"answer":20,"analysis":33},933941,"飞机库与其他建筑物之间应保持一定的防火间距，下列关于其防火间距的说法中，不正确的是（）。",[458,460,462,464],{"key":20,"text":459,"correct":26},"飞机库与高层航材库的防火间距不应小于15m",{"key":24,"text":461,"correct":22},"飞机库与机场油库的防火间距不应小于100m",{"key":28,"text":463,"correct":22},"飞机库与丙类物品库房的防火间距不应小于14m",{"key":31,"text":465,"correct":22},"飞机库与重要的公共建筑的防火间距不应小于50m",{"id":467,"libraryId":5,"type":15,"typeLabel":16,"stem":468,"options":469,"answer":28,"analysis":33},933942,"Ⅲ类飞机库飞机停放和维修区内设置的主要灭火设施为（ ）。",[470,472,474,476],{"key":20,"text":471,"correct":22},"泡沫一水雨淋系统",{"key":24,"text":473,"correct":22},"自动喷水灭火系统",{"key":28,"text":475,"correct":26},"泡沫枪",{"key":31,"text":477,"correct":22},"低倍数泡沫自动灭火系统",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":24,"analysis":33},933943,"仅能停放和维修1～2架中型飞机的飞机库为（ ）。",[482,483,484,485],{"key":20,"text":342,"correct":22},{"key":24,"text":344,"correct":26},{"key":28,"text":346,"correct":22},{"key":31,"text":486,"correct":22},"停机库",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":28,"analysis":33},933944,"下列可以判定为Ⅱ类飞机库的是（ ）。",[491,493,495,497],{"key":20,"text":492,"correct":22},"飞机库停放和维修区的防火分区的最大允许建筑面积为1000m2",{"key":24,"text":494,"correct":22},"飞机停放和维修区的防火分区的最大允许建筑面积为3000m2",{"key":28,"text":496,"correct":26},"飞机停放和维修区的防火分区的最大允许建筑面积为4000m2",{"key":31,"text":498,"correct":22},"飞机停放和维修区的防火分区的最大允许建筑面积为8000m2",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":24,"analysis":33},933945,"下列关于Ⅰ类飞机库的说法，正确的是（ ）。",[503,505,507,509],{"key":20,"text":504,"correct":22},"飞机库内飞机停放和维修区的防火分区最大允许建筑面积为10000m2",{"key":24,"text":506,"correct":26},"飞机停放和维修区与单层维修工作间之间应采用耐火极限不低于2．00h的不燃烧墙体分隔",{"key":28,"text":508,"correct":22},"飞机库内防火分区之间应采用防火墙分隔，设置防火墙确有困难时可用耐火极限不低于3．00h的防火卷帘全部代替",{"key":31,"text":510,"correct":22},"飞机库的耐火等级不应低于二级",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":24,"analysis":33},933946,"关于飞机库总平面布局和平面布置，下列说法中不正确的是（ ）。",[515,517,519,521],{"key":20,"text":516,"correct":22},"两座相邻的飞机库，当较高一面外墙为防火墙时，其防火间距不限",{"key":24,"text":518,"correct":26},"危险品库房不应设置在飞机库的地下部分，但可以设置在飞机库的地上部分",{"key":28,"text":520,"correct":22},"飞机库与喷漆机库贴邻建造时，应采用防火墙分隔",{"key":31,"text":522,"correct":22},"Ⅱ类飞机库应设置环形消防车道",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":20,"analysis":33},933947,"某飞机库为Ⅱ类飞机库，下列有关该飞机库安全疏散和供配电的说法中，不正确的是（ ）。",[527,529,531,533],{"key":20,"text":528,"correct":26},"飞机停放和维修区内的地下通行地沟应至少设有1个通向室外的安全出口",{"key":24,"text":530,"correct":22},"消防电源负荷等级应为一级",{"key":28,"text":532,"correct":22},"飞机停放和维修区内疏散用应急照明的地面照度不应低于1．0lx",{"key":31,"text":534,"correct":22},"飞机停放和维修区的地面上应设置标示疏散方向和疏散通道宽度的永久性标线",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":31,"analysis":33},933948,"消防设施的配置对于飞机库的防火至关重要，下列关于飞机库设置的消防设施的说法，不正确的是（ ）。",[539,541,543,545],{"key":20,"text":540,"correct":22},"飞机停放和维修区内的排水系统可以采用排水沟，也可以采用地下管道",{"key":24,"text":542,"correct":22},"消防泵房内设置的内燃机采用集中的油箱供油时，应设置储油间",{"key":28,"text":544,"correct":22},"消防泵房内可以设置自动喷水灭火系统或其他灭火设施",{"key":31,"text":546,"correct":26},"Ⅰ类飞机库设置自动喷水灭火系统时，系统作用面积不应大于1400m2",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":28,"analysis":33},933949,"飞机库的长边长度大于220．0m时，应设置进出飞机停放和维修区的消防车出入口，消防车出入飞机库的门净宽不应小于车宽加1．0m，门净高度不应小于车高加0．5m，且门的净宽度和净高度均不应小于（ ）m。",[551,553,555,557],{"key":20,"text":552,"correct":22},"3．5",{"key":24,"text":554,"correct":22},"4．0",{"key":28,"text":556,"correct":26},"4．5",{"key":31,"text":558,"correct":22},"5．5",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":24,"analysis":33},933950,"下列关于飞机库防火设计中电气设计的说法错误的是（ ）。",[563,565,567,569],{"key":20,"text":564,"correct":22},"飞机停放和维修区内电源插座距地面安装高度应大于1．0m",{"key":24,"text":566,"correct":26},"飞机停放和维修区内疏散用应急照明的地面照度不应低于2．0lx",{"key":28,"text":568,"correct":22},"当应急照明采用蓄电池作电源时，其连续供电时间不应少于30min",{"key":31,"text":570,"correct":22},"消防用电设备的双路电源线路应分开敷设",{"id":572,"libraryId":5,"type":15,"typeLabel":16,"stem":573,"options":574,"answer":28,"analysis":33},933951,"飞机库的下列部位可以采用难燃烧材料的是（ ）。",[575,577,579,581],{"key":20,"text":576,"correct":22},"外围护结构",{"key":24,"text":578,"correct":22},"内部隔墙",{"key":28,"text":580,"correct":26},"大门",{"key":31,"text":582,"correct":22},"屋面保温隔热层",{"id":584,"libraryId":5,"type":93,"typeLabel":94,"stem":585,"options":586,"answer":166,"analysis":33},933952,"关于飞机库的建筑构造，说法正确的是（ ）。",[587,589,591,593,595],{"key":20,"text":588,"correct":26},"飞机库的外围结构、内部隔墙和屋面保温隔热层均应采用不燃材料",{"key":24,"text":590,"correct":26},"飞机库大门及采光材料应采用不燃或难燃材料",{"key":28,"text":592,"correct":26},"飞机库地面下的沟、坑均应采用不渗透液体的不燃材料建造",{"key":31,"text":594,"correct":22},"飞机停放和维修区的工作间壁、工作台和物品柜等均应采用难燃材料制作。飞机停放和维修区的地面应采用不燃材料",{"key":106,"text":596,"correct":26},"飞机库的防火墙应设置在基础上或相同耐火极限的承重构件上。输送可燃气体和甲、乙、丙类液体的管道严禁穿过防火墙。其他管道不宜穿过防火墙，当确需穿过时，应采用防火封堵材料将空隙填塞密实",{"id":598,"libraryId":5,"type":93,"typeLabel":94,"stem":599,"options":600,"answer":108,"analysis":33},933953,"消防用水可由（ ）供给。",[601,603,605,607,609],{"key":20,"text":602,"correct":26},"市政给水管网",{"key":24,"text":604,"correct":26},"天然水源",{"key":28,"text":606,"correct":22},"游泳池",{"key":31,"text":608,"correct":26},"消防水池",{"key":106,"text":610,"correct":22},"生活水池",{"id":612,"libraryId":5,"type":93,"typeLabel":94,"stem":613,"options":614,"answer":625,"analysis":33},933954,"下列关于汽车库之间以及汽车库与民用建筑之间防火间距的说法中，正确的有（ ）。",[615,617,619,621,623],{"key":20,"text":616,"correct":26},"一级耐火等级的多层汽车库之间的防火间距不应小于10m",{"key":24,"text":618,"correct":22},"一级耐火等级的多层汽车库与高层住宅楼之间的防火间距不应小于12m",{"key":28,"text":620,"correct":26},"甲、乙类物品运输车的车库与重要公共建筑之间的防火间距不应小于50m",{"key":31,"text":622,"correct":22},"甲类物品运输车的车库与明火或散发火花地点的防火间距不应小于25m",{"key":106,"text":624,"correct":26},"停车场的汽车宜分组停放，组与组之间的防火间距不应小于6m","ACE",[627,630,633,636,639,642],{"id":15,"name":628,"category":7,"favorite":629},"领导干部任职前廉政法规知识测试题",92,{"id":631,"name":632,"category":7,"favorite":15},595,"建筑结构与设备",{"id":634,"name":635,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":637,"name":638,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":640,"name":641,"category":7,"favorite":8},534,"BIM工程师",{"id":643,"name":641,"category":7,"favorite":8},535]