[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-43":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":608},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,43,50,2960,[13,38,53,68,82,94,106,118,130,142,154,166,177,189,201,212,222,233,244,253,264,276,288,300,311,323,333,345,357,369,379,387,398,410,421,436,450,462,474,486,498,510,522,532,544,556,566,578,587,596],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},933805,2,"多选题","地铁车站疏散楼梯和疏散通道的宽度应满足（ ）的要求。",[19,23,26,30,33],{"key":20,"text":21,"correct":22},"A","公共区单向通行人行楼梯宽度不应小于1．8m，双向通行不应小于2．4m",true,{"key":24,"text":25,"correct":22},"B","设备、管理区房间单面布置时，疏散通道宽度不应小于1．2m；双面布置时，不应小于1．5m",{"key":27,"text":28,"correct":29},"C","区间通向站台的人行楼梯宽度，不应小于1．2m",false,{"key":31,"text":32,"correct":22},"D","区间风井内的疏散楼梯及消防专用通道的宽度，不应小于1．2m",{"key":34,"text":35,"correct":22},"E","乘客出入口通道的疏散路线应各自独立，不得重叠，也不得设置尽端式袋形走道、门槛和有碍疏散的物体。当两出入口汇集合用同一个疏散通道出地面时，应视为一个安全疏散口","ABDE","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},933806,"地下车站中，应设置机械防烟排烟设施的是（ ）。",[42,44,46,48,50],{"key":20,"text":43,"correct":22},"站台",{"key":24,"text":45,"correct":22},"站厅",{"key":27,"text":47,"correct":22},"防烟楼梯间",{"key":31,"text":49,"correct":29},"连续长度大于150m的区间隧道",{"key":34,"text":51,"correct":22},"连续长度大于200m的全封闭车道","ABCE",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},933807,"下列关于地铁防火的相关描述错误的有 （ ）。",[57,59,61,63,65],{"key":20,"text":58,"correct":22},"地铁安全疏散应按一条线路、一座换乘车站及其区间同一时间内各发生一处火灾事故考虑",{"key":24,"text":60,"correct":22},"车站的安全出口应分散设置，当同方向设置时，两个安全出口通道口部之间净距不应小于5m",{"key":27,"text":62,"correct":29},"地上的车站站厅公共区采用机械排烟时，防火分区的最大允许建筑面积不应大于5000m2，其他部位每个防火分区的最大允许建筑面积不应大于2500m2",{"key":31,"text":64,"correct":29},"地下换乘车站当共用一个站厅时，站厅公共区面积不应大于5000m2",{"key":34,"text":66,"correct":29},"重要设备用房应以耐火极限不低于2．00h的防火隔墙和耐火极限不低于1．50h的楼板与其他部位隔开","AB",{"id":69,"libraryId":5,"type":70,"typeLabel":71,"stem":72,"options":73,"answer":24,"analysis":37},933808,1,"单选题","下列关于地铁车站疏散走道长度的说法，正确的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":29},"当设备与管理用房房间疏散门位于两个安全出口之间时，疏散门与最近安全出口的距离不应大于30m",{"key":24,"text":77,"correct":22},"当设备与管理用房房间位于袋形走道两侧或尽端时，其疏散门与最近安全出口的距离不应大于22m",{"key":27,"text":79,"correct":29},"地下出入口通道的长度不宜超过50m",{"key":31,"text":81,"correct":29},"设备与管理用房房间内任意一点到最近疏散门的距离不应大于9m",{"id":83,"libraryId":5,"type":70,"typeLabel":71,"stem":84,"options":85,"answer":31,"analysis":37},933809,"关于地铁建筑防火的疏散宽度和距离，叙述正确的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":29},"当房间位于袋形走道两侧或尽端时，其疏散门与最近安全出口的距离不应大于15m",{"key":24,"text":89,"correct":29},"地下出入口通道的长度不宜超过90m，超过时应采取满足人员消防疏散要求的措施",{"key":27,"text":91,"correct":29},"当房间疏散门位于两个安全出口之间时，疏散门与最近安全出口的距离不应大于35m",{"key":31,"text":93,"correct":22},"当设备与管理用房区的房间单面布置时，疏散通道宽度不得小于1．2m，双面布置时不得小于1．5m",{"id":95,"libraryId":5,"type":70,"typeLabel":71,"stem":96,"options":97,"answer":31,"analysis":37},933810,"地铁的火灾危险性不包括（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":29},"空间小、人员密度和流量大",{"key":24,"text":101,"correct":29},"用电设施、设备繁多",{"key":27,"text":103,"correct":29},"动态火灾隐患多",{"key":31,"text":105,"correct":22},"救援困难",{"id":107,"libraryId":5,"type":70,"typeLabel":71,"stem":108,"options":109,"answer":31,"analysis":37},933811,"下列关于地铁防火分隔措施的说法，正确的是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":29},"地铁车站两个防火分区之间应采用无门、窗、洞口且耐火极限不低于3．00h的防火墙分隔",{"key":24,"text":113,"correct":29},"地铁车站两个防火分区之间应采用耐火极限不低于3．00h的防火墙，防火墙设有观察窗时，应采用乙级防火窗",{"key":27,"text":115,"correct":29},"地铁车站两个防火分区之间应采用耐火极限不低于3．00h的防火墙分隔和乙级防火门分隔",{"key":31,"text":117,"correct":22},"地铁车站两个防火分区之间应采用耐火极限不低于3．00h的防火墙分隔，其楼板采用耐火极限不低于1．50h的楼板",{"id":119,"libraryId":5,"type":70,"typeLabel":71,"stem":120,"options":121,"answer":27,"analysis":37},933812,"地铁车站重要设备用房应以耐火极限不低于（ ）h的隔墙和耐火极限不低于（ ）h的楼板与其他部位隔开。",[122,124,126,128],{"key":20,"text":123,"correct":29},"3．0，1．5",{"key":24,"text":125,"correct":29},"2．5，1．0",{"key":27,"text":127,"correct":22},"2．0，1．5",{"key":31,"text":129,"correct":29},"3．0，1．0",{"id":131,"libraryId":5,"type":70,"typeLabel":71,"stem":132,"options":133,"answer":24,"analysis":37},933813,"地下线路应急照明的连续供电时间不应小于（ ）min。",[134,136,138,140],{"key":20,"text":135,"correct":29},"30",{"key":24,"text":137,"correct":22},"60",{"key":27,"text":139,"correct":29},"120",{"key":31,"text":141,"correct":29},"180",{"id":143,"libraryId":5,"type":70,"typeLabel":71,"stem":144,"options":145,"answer":27,"analysis":37},933814,"地铁车站两个防火分区之间应采用耐火极限不低于（ ）h的防火墙和（ ）防火门分隔。",[146,148,150,152],{"key":20,"text":147,"correct":29},"1．50，甲级",{"key":24,"text":149,"correct":29},"2．00，乙级",{"key":27,"text":151,"correct":22},"3．00，甲级",{"key":31,"text":153,"correct":29},"2．50，乙级",{"id":155,"libraryId":5,"type":70,"typeLabel":71,"stem":156,"options":157,"answer":27,"analysis":37},933815,"地铁车站站台、站厅公共区内的疏散指示标志应采用电光源型，并设置在柱面或墙面上。标志上边缘距地面不应大于（ ）m，间距不应大于（ ）m或不应超过二跨柱间距。",[158,160,162,164],{"key":20,"text":159,"correct":29},"0．5，10",{"key":24,"text":161,"correct":29},"0．5，20",{"key":27,"text":163,"correct":22},"1，20",{"key":31,"text":165,"correct":29},"2．2，10",{"id":167,"libraryId":5,"type":70,"typeLabel":71,"stem":168,"options":169,"answer":31,"analysis":37},933816,"下列关于地铁防火防烟分区划分的说法，错误的是（ ）。",[170,172,173,175],{"key":20,"text":171,"correct":29},"地下车站站台和站厅公共区应划为一个防火分区",{"key":24,"text":64,"correct":29},{"key":27,"text":174,"correct":29},"站厅与站台的公共区每个防烟分区的建筑面积不宜超过2000m2",{"key":31,"text":176,"correct":22},"设备与管理用房每个防烟分区的建筑面积不宜超过500m2",{"id":178,"libraryId":5,"type":70,"typeLabel":71,"stem":179,"options":180,"answer":31,"analysis":37},933817,"北京地铁 9 号线和 4 号线，在国家图书馆站为地下换乘车站，共用一个站厅，该站厅公共区面积不应大于（ ）㎡。",[181,183,185,187],{"key":20,"text":182,"correct":29},"1500",{"key":24,"text":184,"correct":29},"2000",{"key":27,"text":186,"correct":29},"2500",{"key":31,"text":188,"correct":22},"5000",{"id":190,"libraryId":5,"type":70,"typeLabel":71,"stem":191,"options":192,"answer":31,"analysis":37},933818,"车站站台公共区的楼梯、自动扶梯、出入口通道，应满足当发生火灾时在（ ）min内将远期或客流控制期超高峰小时一列进站列车所载的乘客及站台上的候车人员全部撤离站台到达安全区的要求。",[193,195,197,199],{"key":20,"text":194,"correct":29},"1",{"key":24,"text":196,"correct":29},"3",{"key":27,"text":198,"correct":29},"5",{"key":31,"text":200,"correct":22},"6",{"id":202,"libraryId":5,"type":70,"typeLabel":71,"stem":203,"options":204,"answer":27,"analysis":37},933819,"某城市一条地铁车站内要设置防烟排烟设施。下列关于防烟分区划分的规定中，不正确的是（ ）。",[205,206,208,210],{"key":20,"text":174,"correct":29},{"key":24,"text":207,"correct":29},"防烟分区可设置挡烟垂壁",{"key":27,"text":209,"correct":22},"设备与管理用房每个防烟分区的建筑面积不宜超过1000m2",{"key":31,"text":211,"correct":29},"防烟分区不得跨越防火分区",{"id":213,"libraryId":5,"type":70,"typeLabel":71,"stem":214,"options":215,"answer":20,"analysis":37},933820,"地铁中两个防火分区之间应采用耐火极限不低于（ ）h的防火墙和（ ）级防火门分隔。",[216,217,218,220],{"key":20,"text":151,"correct":22},{"key":24,"text":153,"correct":29},{"key":27,"text":219,"correct":29},"2．00，丙级",{"key":31,"text":221,"correct":29},"1．50，丁级",{"id":223,"libraryId":5,"type":70,"typeLabel":71,"stem":224,"options":225,"answer":31,"analysis":37},933821,"区间火灾排烟应按单洞区间隧道断面的排烟流速不小于2m／s，且高于计算临界烟气控制流速，但排烟流速不得大于（ ）m／s设计，并应保证烟气不进入车站隧道区域。",[226,227,229,231],{"key":20,"text":198,"correct":29},{"key":24,"text":228,"correct":29},"7",{"key":27,"text":230,"correct":29},"9",{"key":31,"text":232,"correct":22},"11",{"id":234,"libraryId":5,"type":70,"typeLabel":71,"stem":235,"options":236,"answer":24,"analysis":37},933822,"根据《地铁设计防火标准》GB1298-2018，车站的每个站厅公共区均应设置不少于两个直通室外的安全出口。安全出口应分散布置，且相邻两个安全出口之间的最小水平距离不应小于（ ）m。",[237,239,241,243],{"key":20,"text":238,"correct":29},"15",{"key":24,"text":240,"correct":22},"20",{"key":27,"text":242,"correct":29},"25",{"key":31,"text":135,"correct":29},{"id":245,"libraryId":5,"type":70,"typeLabel":71,"stem":246,"options":247,"answer":31,"analysis":37},933823,"地上车站公共区采用机械排烟时，防火分区的最大允许建筑面积不应大于（ ）m2。",[248,249,250,252],{"key":20,"text":182,"correct":29},{"key":24,"text":184,"correct":29},{"key":27,"text":251,"correct":29},"4000",{"key":31,"text":188,"correct":22},{"id":254,"libraryId":5,"type":70,"typeLabel":71,"stem":255,"options":256,"answer":27,"analysis":37},933824,"地铁建筑站厅公共区和站台计算长度内任一点到梯口或疏散通道口的最大疏散距离不应大于（ ）m。",[257,259,261,263],{"key":20,"text":258,"correct":29},"35",{"key":24,"text":260,"correct":29},"40",{"key":27,"text":262,"correct":22},"50",{"key":31,"text":137,"correct":29},{"id":265,"libraryId":5,"type":70,"typeLabel":71,"stem":266,"options":267,"answer":20,"analysis":37},933825,"根据《地铁设计规范》（GB 50157-2013），下列关于地铁防烟、排烟系统与事故通风系统功能的说法中，错误的是（ ）。",[268,270,272,274],{"key":20,"text":269,"correct":22},"当区间隧道发生火灾时，应迎着乘客主要疏散方向排烟，背着乘客疏散方向送新风",{"key":24,"text":271,"correct":29},"当地下车站的站厅、站台发生火灾时，应具备防烟、排烟、通风功能",{"key":27,"text":273,"correct":29},"当地面或高架车站发生火灾时．应具备排烟功能",{"key":31,"text":275,"correct":29},"当设备与管理用房发生火灾时，应具备防烟、排烟、通风功能",{"id":277,"libraryId":5,"type":70,"typeLabel":71,"stem":278,"options":279,"answer":24,"analysis":37},933826,"下列关于地铁车站疏散指示标志设置的说法，错误的是（ ）。",[280,282,284,286],{"key":20,"text":281,"correct":29},"疏散通道交叉口、沿通道长向每隔不大于10m处，应设置灯光疏散指示标志",{"key":24,"text":283,"correct":22},"疏散通道拐弯处应设置灯光疏散指示标志，指示标志距地面应不小于1m",{"key":27,"text":285,"correct":29},"疏散门、安全出口应设置灯光疏散指示标志，并宜设置在门洞正上方",{"key":31,"text":287,"correct":29},"车站公共区站台的地面上，以及疏散楼梯台阶侧立面，应设蓄光疏散指示标志，并应保持视觉连续",{"id":289,"libraryId":5,"type":70,"typeLabel":71,"stem":290,"options":291,"answer":27,"analysis":37},933827,"下列场所应设置机械排烟设施的是（ ）。",[292,294,296,298],{"key":20,"text":293,"correct":29},"同一个防火分区内的地下车站设备与管理用房的总面积为200m2",{"key":24,"text":295,"correct":29},"地铁车站内面积为50m2且经常有人停留的单个房间",{"key":27,"text":297,"correct":22},"地铁车站内最远点到车站公共区的直线距离为25m的内走道",{"key":31,"text":299,"correct":29},"地铁车站内连续长度为50m的地下通道和出入口通道",{"id":301,"libraryId":5,"type":70,"typeLabel":71,"stem":302,"options":303,"answer":24,"analysis":37},933828,"下列不属于地铁火灾特点的是（ ）。",[304,306,307,309],{"key":20,"text":305,"correct":29},"火情探测和扑救困难",{"key":24,"text":103,"correct":22},{"key":27,"text":308,"correct":29},"产生有毒烟气、排烟排热效果差",{"key":31,"text":310,"correct":29},"人员疏散困难",{"id":312,"libraryId":5,"type":70,"typeLabel":71,"stem":313,"options":314,"answer":24,"analysis":37},933829,"下列地铁场所建筑必须采用一级耐火等级的是（ ）。",[315,317,319,321],{"key":20,"text":316,"correct":29},"地面出入口",{"key":24,"text":318,"correct":22},"控制中心",{"key":27,"text":320,"correct":29},"高架车站",{"key":31,"text":322,"correct":29},"地面车站",{"id":324,"libraryId":5,"type":70,"typeLabel":71,"stem":325,"options":326,"answer":27,"analysis":37},933830,"下列关于地铁防火分区划分的说法，错误的是（ ）。",[327,328,329,331],{"key":20,"text":171,"correct":29},{"key":24,"text":64,"correct":29},{"key":27,"text":330,"correct":22},"地上的车站站厅公共区采用自动喷水灭火系统时，防火分区的最大允许建筑面积不应大于5000m2",{"key":31,"text":332,"correct":29},"设备与管理用房区每个防火分区的最大允许使用面积不应大于1500m2",{"id":334,"libraryId":5,"type":70,"typeLabel":71,"stem":335,"options":336,"answer":20,"analysis":37},933831,"下列关于地铁安全出口的说法，错误的是（ ）。",[337,339,341,343],{"key":20,"text":338,"correct":22},"消防专用通道、设在两侧式站台之间的过轨地道必要时可以作为安全出口",{"key":24,"text":340,"correct":29},"安全出口同方向设置时，两个安全出口通道口部之间净距不应小于20m",{"key":27,"text":342,"correct":29},"地下车站的设备与管理用房中有人值守的防火分区应有1个安全出口直通地面",{"key":31,"text":344,"correct":29},"地下换乘车站的换乘通道不应作为安全出口",{"id":346,"libraryId":5,"type":70,"typeLabel":71,"stem":347,"options":348,"answer":31,"analysis":37},933832,"下列关于地铁装修的说法，错误的是（ ）。",[349,351,353,355],{"key":20,"text":350,"correct":29},"地下车站的垃圾箱，应采用燃烧性能等级为A级的不燃材料",{"key":24,"text":352,"correct":29},"地上车站公共区墙面、顶棚的装修材料，应采用A级不燃材料，地面应采用不低于B1级难燃材料",{"key":27,"text":354,"correct":29},"地下车站公共区的广告灯箱应采用不低于B1级难燃材料",{"key":31,"text":356,"correct":22},"地下车站设备与管理用房的顶棚、墙面、地面装修材料，可以采用岩棉",{"id":358,"libraryId":5,"type":70,"typeLabel":71,"stem":359,"options":360,"answer":27,"analysis":37},933833,"地铁设备与管理用房区房间双面布置时，疏散通道宽度不得小于（ ）m。",[361,363,365,367],{"key":20,"text":362,"correct":29},"1．2",{"key":24,"text":364,"correct":29},"1．4",{"key":27,"text":366,"correct":22},"1．5",{"key":31,"text":368,"correct":29},"1．8",{"id":370,"libraryId":5,"type":70,"typeLabel":71,"stem":371,"options":372,"answer":27,"analysis":37},933834,"地下车站的公共区应划分防烟分区，站厅与站台的公共区每个防烟分区的建筑面积不宜超过（ ）㎡。",[373,375,377,378],{"key":20,"text":374,"correct":29},"500",{"key":24,"text":376,"correct":29},"1000",{"key":27,"text":184,"correct":22},{"key":31,"text":186,"correct":29},{"id":380,"libraryId":5,"type":70,"typeLabel":71,"stem":381,"options":382,"answer":27,"analysis":37},933835,"有人值守的车站设备、管理用房的门位于2个安全出口之间时，其房间门至最近安全出口的距离不应大于（ ）m。",[383,384,385,386],{"key":20,"text":240,"correct":29},{"key":24,"text":135,"correct":29},{"key":27,"text":260,"correct":22},{"key":31,"text":262,"correct":29},{"id":388,"libraryId":5,"type":70,"typeLabel":71,"stem":389,"options":390,"answer":31,"analysis":37},933836,"地下车站设置的商铺总面积超过（ ）m2时应设自动喷水灭火系统。",[391,393,395,397],{"key":20,"text":392,"correct":29},"150",{"key":24,"text":394,"correct":29},"300",{"key":27,"text":396,"correct":29},"400",{"key":31,"text":374,"correct":22},{"id":399,"libraryId":5,"type":70,"typeLabel":71,"stem":400,"options":401,"answer":24,"analysis":37},933837,"地铁车站中有人值守的设备管理区内，其每个防火分区安全出口的数量不应少于（ ）个。",[402,404,406,408],{"key":20,"text":403,"correct":29},"一",{"key":24,"text":405,"correct":22},"二",{"key":27,"text":407,"correct":29},"三",{"key":31,"text":409,"correct":29},"四",{"id":411,"libraryId":5,"type":70,"typeLabel":71,"stem":412,"options":413,"answer":20,"analysis":37},933838,"下列关于地铁防烟分区说法错误的是（ ）。",[414,416,418,420],{"key":20,"text":415,"correct":22},"地下车站站厅、站台的公共区每个防烟分区的建筑面积不宜小于750m2",{"key":24,"text":417,"correct":29},"站台至站厅的楼扶梯等开口四周的临空部位应设置挡烟垂壁",{"key":27,"text":419,"correct":29},"设备管理区每个防烟分区的建筑面积不应大于750m2",{"key":31,"text":211,"correct":29},{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":435,"analysis":37},933839,"以下场所需设置防排烟系统的有（ ）。",[425,427,429,431,433],{"key":20,"text":426,"correct":22},"地下或封闭车站的站厅公共区、站台公共区",{"key":24,"text":428,"correct":29},"同一个防火分区内的地下车站设备及管理用房的使用面积超过150m2，或面积超过50m2经常有人停留的单个房间",{"key":27,"text":430,"correct":22},"连续长度大于一列列车长度的地下区间和全封闭车道",{"key":31,"text":432,"correct":29},"连续长度大于60m，但小于等于300m的全封闭载客车行区间",{"key":34,"text":434,"correct":22},"连续长度大于60m的地下通道和出入口通道，设备管理用房门至安全出口距离大于20m的内走道","ACE",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":52,"analysis":37},933840,"下列选项属于隧道火灾特点的是（ ）",[440,442,444,446,448],{"key":20,"text":441,"correct":22},"火灾多样性",{"key":24,"text":443,"correct":22},"燃烧形式多样性",{"key":27,"text":445,"correct":22},"火灾烟气流动性",{"key":31,"text":447,"correct":29},"安全疏散具有方向性",{"key":34,"text":449,"correct":22},"灭火救援艰难性",{"id":451,"libraryId":5,"type":70,"typeLabel":71,"stem":452,"options":453,"answer":31,"analysis":37},933841,"下列选项不属于隧道火灾危害性的是（ ）",[454,456,458,460],{"key":20,"text":455,"correct":29},"人员伤亡多",{"key":24,"text":457,"correct":29},"经济损失巨大",{"key":27,"text":459,"correct":29},"次生灾害危害严重",{"key":31,"text":461,"correct":22},"火灾点的移动性",{"id":463,"libraryId":5,"type":70,"typeLabel":71,"stem":464,"options":465,"answer":20,"analysis":37},933842,"隧道采用的排烟模式通常可分为纵向、横向（半横向）及重点模式，以及由基本模式派生的各种组合模式，其中（ ）排烟方式较适用于单向行驶、交通量不高的隧道。",[466,468,470,472],{"key":20,"text":467,"correct":22},"纵向",{"key":24,"text":469,"correct":29},"横向",{"key":27,"text":471,"correct":29},"组合",{"key":31,"text":473,"correct":29},"重点",{"id":475,"libraryId":5,"type":70,"typeLabel":71,"stem":476,"options":477,"answer":31,"analysis":37},933843,"下列关于隧道内防火分区划分和防火分隔的说法，正确的是（ ）。",[478,480,482,484],{"key":20,"text":479,"correct":29},"隧道内地下设备用房的每个防火分区的最大允许建筑面积不应大于1000m2",{"key":24,"text":481,"correct":29},"隧道内的变电站应采取耐火极限不低于2．00h的防火隔墙和甲级防火门等分隔措施与车行隧道分隔",{"key":27,"text":483,"correct":29},"隧道内的专用疏散通道应采取耐火极限不低于3．00h的防火隔墙和乙级防火门等分隔措施与车行隧道分隔",{"key":31,"text":485,"correct":22},"隧道内的通风机房应采取耐火极限不低于2．00h的防火隔墙和乙级防火门等分隔措施与车行隧道分隔",{"id":487,"libraryId":5,"type":70,"typeLabel":71,"stem":488,"options":489,"answer":20,"analysis":37},933844,"下列关于消防用水量的说法，错误的是（ ）。",[490,492,494,496],{"key":20,"text":491,"correct":22},"隧道内的消火栓用水量不应小于40L／s",{"key":24,"text":493,"correct":29},"隧道外的消火栓用水量不应小于30L／s",{"key":27,"text":495,"correct":29},"对于长度小于1000m的三类隧道，隧道外的消火栓用水量可为20L／s",{"key":31,"text":497,"correct":29},"对于长度小于1000m的三类隧道，隧道内的消火栓用水量可为10L／s",{"id":499,"libraryId":5,"type":70,"typeLabel":71,"stem":500,"options":501,"answer":24,"analysis":37},933845,"下列关于城市交通隧道机械排烟系统的设置的说法，错误的是（ ）。",[502,504,506,508],{"key":20,"text":503,"correct":29},"长度大于3000m的隧道，宜采用重点排烟方式",{"key":24,"text":505,"correct":22},"长度不大于3000m的单洞单向交通隧道，宜采用分段排烟方式",{"key":27,"text":507,"correct":29},"单洞双向交通隧道，宜采用重点排烟方式",{"key":31,"text":509,"correct":29},"长度大于3000m的隧道，宜采用纵向分段排烟方式",{"id":511,"libraryId":5,"type":70,"typeLabel":71,"stem":512,"options":513,"answer":31,"analysis":37},933846,"隧道内设置的机械排烟风机应能承受设计的隧道火灾烟气排放温度，并应能在（ ）℃下连续正常运行不小于（ ）min。",[514,516,518,520],{"key":20,"text":515,"correct":29},"70，30",{"key":24,"text":517,"correct":29},"250，30",{"key":27,"text":519,"correct":29},"280，30",{"key":31,"text":521,"correct":22},"250，60",{"id":523,"libraryId":5,"type":70,"typeLabel":71,"stem":524,"options":525,"answer":27,"analysis":37},933847,"隧道行车道旁的电缆沟顶部应高于路面，且不应小于（ ）mm。",[526,528,529,531],{"key":20,"text":527,"correct":29},"100",{"key":24,"text":392,"correct":29},{"key":27,"text":530,"correct":22},"200",{"key":31,"text":394,"correct":29},{"id":533,"libraryId":5,"type":70,"typeLabel":71,"stem":534,"options":535,"answer":20,"analysis":37},933848,"某地一条城市交通隧道，长度为3000m，根据现行国家工程建设消防技术标准，下列说法中不正确的是（ ）。",[536,538,540,542],{"key":20,"text":537,"correct":22},"该隧道内的消火栓用水量不应小于15L\u002Fs",{"key":24,"text":539,"correct":29},"按照隧道长度分类标准，该隧道属于长隧道",{"key":27,"text":541,"correct":29},"隧道内的变电站应采用耐火极限不低于2.00h的防火隔墙和顶板乙级防火门等分隔措施与车行隧道分隔",{"key":31,"text":543,"correct":29},"隧道内地下设备用房的每个防火分区的最大允许建筑面积不大于1500m2",{"id":545,"libraryId":5,"type":70,"typeLabel":71,"stem":546,"options":547,"answer":24,"analysis":37},933849,"隧道入口外（ ）处，应设置隧道内发生火灾时能提示车辆禁入隧道的警报信号装置。",[548,550,552,554],{"key":20,"text":549,"correct":29},"50～100m",{"key":24,"text":551,"correct":22},"100～150m",{"key":27,"text":553,"correct":29},"150～200m",{"key":31,"text":555,"correct":29},"200～300m",{"id":557,"libraryId":5,"type":70,"typeLabel":71,"stem":558,"options":559,"answer":24,"analysis":37},933850,"一、二类隧道内疏散照明和疏散指示标志的连续供电时间不应小于（ ）h。",[560,561,562,564],{"key":20,"text":194,"correct":29},{"key":24,"text":366,"correct":22},{"key":27,"text":563,"correct":29},"2",{"key":31,"text":565,"correct":29},"2．5",{"id":567,"libraryId":5,"type":70,"typeLabel":71,"stem":568,"options":569,"answer":20,"analysis":37},933851,"为隧道供电的柴油发电机房设置的储油间，应采用防火墙和能自行关闭的（ ）防火门与发电机房和其他部位分隔开。",[570,572,574,576],{"key":20,"text":571,"correct":22},"甲级",{"key":24,"text":573,"correct":29},"乙级",{"key":27,"text":575,"correct":29},"丙级",{"key":31,"text":577,"correct":29},"丁级",{"id":579,"libraryId":5,"type":70,"typeLabel":71,"stem":580,"options":581,"answer":27,"analysis":37},933852,"隧道封闭段长度超过（ ）m的隧道宜设置消防控制室。",[582,583,585,586],{"key":20,"text":374,"correct":29},{"key":24,"text":584,"correct":29},"800",{"key":27,"text":376,"correct":22},{"key":31,"text":182,"correct":29},{"id":588,"libraryId":5,"type":70,"typeLabel":71,"stem":589,"options":590,"answer":24,"analysis":37},933853,"隧道入口外（ ）处，应设置报警信号装置。",[591,592,593,594],{"key":20,"text":549,"correct":29},{"key":24,"text":551,"correct":22},{"key":27,"text":553,"correct":29},{"key":31,"text":595,"correct":29},"250～300m",{"id":597,"libraryId":5,"type":70,"typeLabel":71,"stem":598,"options":599,"answer":24,"analysis":37},933854,"隧道内的变电站应采取耐火极限不低于（ ）h的防火隔墙和乙级防火门等分隔措施与车行隧道分隔。",[600,602,604,606],{"key":20,"text":601,"correct":29},"1．50h",{"key":24,"text":603,"correct":22},"2．00h",{"key":27,"text":605,"correct":29},"2．50h",{"key":31,"text":607,"correct":29},"3．00h",[609,612,615,618,621,624],{"id":70,"name":610,"category":7,"favorite":611},"领导干部任职前廉政法规知识测试题",92,{"id":613,"name":614,"category":7,"favorite":70},595,"建筑结构与设备",{"id":616,"name":617,"category":7,"favorite":70},715,"招标采购专业知识与法律法规",{"id":619,"name":620,"category":7,"favorite":70},848,"市政方向-通用基础",{"id":622,"name":623,"category":7,"favorite":8},534,"BIM工程师",{"id":625,"name":623,"category":7,"favorite":8},535]