[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-42":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":623},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,42,50,2960,[13,34,46,58,70,81,90,108,123,138,153,168,183,195,210,225,239,254,266,278,290,301,313,324,334,346,356,368,380,392,404,416,428,440,449,460,472,481,491,503,515,527,539,551,563,575,584,594,606,614],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},933755,1,"单选题","消防水泵是通过叶轮的旋转将能量传递给水，从而增加了水的动能、压力能，并将其输送到灭火设备处，以满足各种灭火设备的水量、水压要求，它是消防给水系统的心脏。目前消防给水系统中使用的水泵大多为（）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","容积式水泵",false,{"key":24,"text":25,"correct":22},"B","轴流泵",{"key":27,"text":28,"correct":22},"C","混流泵",{"key":30,"text":31,"correct":32},"D","离心泵",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},933756,"下列关于分区供水应符合条件的说法，错误的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"系统的工作压力大于2．4MPa",{"key":24,"text":41,"correct":22},"消火栓栓口处静压大于1．0MPa",{"key":27,"text":43,"correct":32},"自动水灭火系统报警阀处的工作压力大于1．50MPa",{"key":30,"text":45,"correct":22},"自动水灭火系统喷头处的工作压力大于1．20MPa",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},933757,"室内消防用水直接由室外消防给水管网提供，构造简单、投资少的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"分区消防给水方式",{"key":24,"text":53,"correct":32},"直接给水方式",{"key":27,"text":55,"correct":22},"不分区消防给水方式",{"key":30,"text":57,"correct":22},"设有水泵和消防水箱给水方式",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},933758,"某商业建筑，东西长100m，南北宽60m，建筑高度26m，室外消火栓设计流量为40L／s，南侧布置消防扑救面。沿该建筑南侧消防扑救面设置的室外消火栓数量，不宜少于（ ）个。",[62,64,66,68],{"key":20,"text":63,"correct":22},"1",{"key":24,"text":65,"correct":32},"2",{"key":27,"text":67,"correct":22},"3",{"key":30,"text":69,"correct":22},"4",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},933759,"室内消火栓栓口的安装高度应便于消防水龙带的连接和使用，其距地高度宜为（ ）m，出水方向宜向下或与设置消火栓的墙面成90°角。",[74,76,78,80],{"key":20,"text":75,"correct":22},"0．8",{"key":24,"text":77,"correct":32},"1．1",{"key":27,"text":79,"correct":22},"1．5",{"key":30,"text":65,"correct":22},{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":24,"analysis":33},933760,"市政消火栓应布置在消防车易于接近的人行道和绿地等地点，且不应妨碍交通。距路边不宜小于0．5m，并不应大于（）m。",[85,86,87,88],{"key":20,"text":63,"correct":22},{"key":24,"text":65,"correct":32},{"key":27,"text":67,"correct":22},{"key":30,"text":89,"correct":22},"5",{"id":91,"libraryId":5,"type":92,"typeLabel":93,"stem":94,"options":95,"answer":107,"analysis":33},933761,2,"多选题","某一级耐火等级多层丙类仓库，建筑总体积5000m3，建筑高度24m，设有室内消火栓系统。下列关于该系统设置的做法，错误的有（ ）。",[96,98,100,102,104],{"key":20,"text":97,"correct":32},"该仓库消火栓栓口动压为0．20MPa",{"key":24,"text":99,"correct":22},"该仓库内消火栓的布置间距为50m",{"key":27,"text":101,"correct":32},"配备长度为30m的消防水带",{"key":30,"text":103,"correct":22},"采用DN65的室内消火栓",{"key":105,"text":106,"correct":32},"E","消防水枪充实水柱为7m","ACE",{"id":109,"libraryId":5,"type":92,"typeLabel":93,"stem":110,"options":111,"answer":122,"analysis":33},933762,"某多层商业楼，室内、外消火栓系统的设计流量均为15L／s，自动喷水灭火系统的设计流量为10L／s。消防水池储存室内消火栓和自动喷水灭火系统的用水量，消防水池有符合要求的补水措施，两路补水量均为35m3／h。下列关于该建筑消防水池有效容积的设置，符合规定的有（ ）m3。",[112,114,116,118,120],{"key":20,"text":113,"correct":22},"50",{"key":24,"text":115,"correct":22},"93",{"key":27,"text":117,"correct":32},"100",{"key":30,"text":119,"correct":32},"128",{"key":105,"text":121,"correct":32},"140","CDE",{"id":124,"libraryId":5,"type":92,"typeLabel":93,"stem":125,"options":126,"answer":137,"analysis":33},933763,"下列关于室内消火栓的设置说法正确的是（ ）。",[127,129,131,133,135],{"key":20,"text":128,"correct":32},"设置室内消火栓的建筑，包括设备层在内的各层均应设置消火栓",{"key":24,"text":130,"correct":22},"室内消火栓的布置应保证有1支水枪的充实水柱同时到达室内任何部位",{"key":27,"text":132,"correct":32},"消防电梯前室应设室内消火栓",{"key":30,"text":134,"correct":32},"建筑室内消火栓栓口中心距地面高度宜为1．1m",{"key":105,"text":136,"correct":32},"消火栓应采用同一型号规格","ACDE",{"id":139,"libraryId":5,"type":92,"typeLabel":93,"stem":140,"options":141,"answer":152,"analysis":33},933764,"下列建筑应设室内消火栓系统的是（ ）。",[142,144,146,148,150],{"key":20,"text":143,"correct":32},"建筑占地面积大于300m2的厂房（仓库）",{"key":24,"text":145,"correct":32},"体积大于5000m3的车站、码头、机场的候车（船、机）楼以及展览建筑、商店、旅馆、病房楼、门诊楼、图书馆等",{"key":27,"text":147,"correct":32},"建筑高度大于15m或体积大于10000m3的办公楼、教学楼",{"key":30,"text":149,"correct":22},"耐火等级为三、四级且建筑体积小于等于5000m3的戊类厂房（仓库）",{"key":105,"text":151,"correct":32},"建筑高度大于21m的住宅","ABCE",{"id":154,"libraryId":5,"type":92,"typeLabel":93,"stem":155,"options":156,"answer":167,"analysis":33},933765,"下列哪些建筑物应设消防水池（）。",[157,159,161,163,165],{"key":20,"text":158,"correct":22},"市政给水管网两路供水，并采用两条引入管，室外消火栓设计流量为25L\u002Fs",{"key":24,"text":160,"correct":32},"市政给水管网一路供水，室外消火栓设计流量为25L\u002Fs",{"key":27,"text":162,"correct":32},"市政给水管网一路供水，室外消火栓设计流量为15L\u002Fs，建筑高度为60m",{"key":30,"text":164,"correct":32},"市政消防给水设计流量小于建筑的消防给水设计流量时",{"key":105,"text":166,"correct":32},"生产、生活用水量达到最大时，市政给水管网不能满足室内、外消防用水量","BCDE",{"id":169,"libraryId":5,"type":92,"typeLabel":93,"stem":170,"options":171,"answer":182,"analysis":33},933766,"某居民住宅楼，地上20层，地下1层，建筑高度58m，采用临时高压消防给水系统，屋顶设置消防水箱。下列关于消防水箱设置的说法中，正确的是（）。",[172,174,176,178,180],{"key":20,"text":173,"correct":22},"水箱的有效容积不应小于12m3",{"key":24,"text":175,"correct":32},"水箱的有效容积不应小于18m3",{"key":27,"text":177,"correct":22},"水箱的最低有效水位应满足最不利点处的静水压力不低于0．1MPa",{"key":30,"text":179,"correct":22},"水箱的最低有效水位应满足最不利点处的静水压力不低于0．15MPa",{"key":105,"text":181,"correct":32},"水箱的最低有效水位应满足最不利点处的静水压力不低于0．07MPa","BE",{"id":184,"libraryId":5,"type":15,"typeLabel":16,"stem":185,"options":186,"answer":30,"analysis":33},933767,"其他建筑、场所防火的基本要求不包括（ ）",[187,189,191,193],{"key":20,"text":188,"correct":22},"合理进行总体规划布局",{"key":24,"text":190,"correct":22},"采取针对性的防火技术措施",{"key":27,"text":192,"correct":22},"配置有效的消防设施",{"key":30,"text":194,"correct":32},"工作人员安全培训",{"id":196,"libraryId":5,"type":92,"typeLabel":93,"stem":197,"options":198,"answer":209,"analysis":33},933768,"下列选择属于其他建筑和场所火灾危险特性的是（ ）",[199,201,203,205,207],{"key":20,"text":200,"correct":32},"具有火灾爆炸的高危性",{"key":24,"text":202,"correct":32},"具有火灾危险源的流动性",{"key":27,"text":204,"correct":32},"具有火灾规模大的危险性",{"key":30,"text":206,"correct":32},"灭火救援困难",{"key":105,"text":208,"correct":22},"火灾损失容易估量","ABCD",{"id":211,"libraryId":5,"type":92,"typeLabel":93,"stem":212,"options":213,"answer":224,"analysis":33},933769,"收藏陈列珍贵文物的古建筑，宜选择的火灾自动报警系统有（ ）。",[214,216,218,220,222],{"key":20,"text":215,"correct":22},"火焰探测器",{"key":24,"text":217,"correct":22},"红外线光束感烟探测器",{"key":27,"text":219,"correct":32},"吸气式早期火灾探测器",{"key":30,"text":221,"correct":32},"线型光纤感温探测器",{"key":105,"text":223,"correct":22},"缆式线型定温探测器","CD",{"id":226,"libraryId":5,"type":92,"typeLabel":93,"stem":227,"options":228,"answer":209,"analysis":33},933770,"石油化工企业的火灾特点有（ ）。",[229,231,233,235,237],{"key":20,"text":230,"correct":32},"爆炸与燃烧并存，易造成人员伤亡",{"key":24,"text":232,"correct":32},"燃烧速度快、火势发展迅猛",{"key":27,"text":234,"correct":32},"易形成立体火灾",{"key":30,"text":236,"correct":32},"火灾扑救困难",{"key":105,"text":238,"correct":22},"人员疏散困难",{"id":240,"libraryId":5,"type":92,"typeLabel":93,"stem":241,"options":242,"answer":253,"analysis":33},933771,"根据《石油库设计规范》规定，下列作业场所中，应设消除人体静电装置的有（）。",[243,245,247,249,251],{"key":20,"text":244,"correct":22},"润滑油泵房的门外2m范围内",{"key":24,"text":246,"correct":32},"轻柴油储罐的上罐扶梯入口处",{"key":27,"text":248,"correct":32},"重柴油储罐的上罐扶梯入口处",{"key":30,"text":250,"correct":32},"石脑油装卸码头的上下船出入口处",{"key":105,"text":252,"correct":22},"100号重油装卸作业区内操作平台的扶梯入口处","BCD",{"id":255,"libraryId":5,"type":15,"typeLabel":16,"stem":256,"options":257,"answer":24,"analysis":33},933772,"下列关于石油化工企业总平面布置的说法，错误的是（ ）。",[258,260,262,264],{"key":20,"text":259,"correct":22},"采用架空电力线路进出厂区的总变电所应布置在厂区边缘",{"key":24,"text":261,"correct":32},"罐区泡沫站应布置在罐组防火堤内的非防爆区，与可燃液体罐的防火间距不宜小于20m",{"key":27,"text":263,"correct":22},"全厂性污水处理场设施宜布置在人员集中场所及明火或散发火花地点的全年最小频率风向的上风侧",{"key":30,"text":265,"correct":22},"液化烃罐组或可燃液体罐组不宜紧靠排洪沟布置",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":24,"analysis":33},933773,"下列关于石油化工企业消防车道设置的说法中，错误的是（ ）。",[270,272,274,276],{"key":20,"text":271,"correct":22},"可燃气体的罐区内，任何储罐的中心距至少两条消防车道的距离均不应大于120m",{"key":24,"text":273,"correct":32},"消防车道的路面宽度和高度不应小于4m×4m",{"key":27,"text":275,"correct":22},"路面内缘转弯半径不宜小于12m",{"key":30,"text":277,"correct":22},"总容积大于或等于120000m3的两个或两个以上可燃液体罐组应设环形消防车道",{"id":279,"libraryId":5,"type":15,"typeLabel":16,"stem":280,"options":281,"answer":30,"analysis":33},933774,"直径大于20m的可燃液体固定顶罐储罐消防冷却用水的延续时间为（ ）h。",[282,284,286,288],{"key":20,"text":283,"correct":22},"2．00",{"key":24,"text":285,"correct":22},"3．00",{"key":27,"text":287,"correct":22},"4．00",{"key":30,"text":289,"correct":32},"6．00",{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":20,"analysis":33},933775,"甲、乙类可燃气体的高大构架和设备群应设置水炮保护，其设置位置距保护对象不宜小于（ ）m。",[294,296,298,299],{"key":20,"text":295,"correct":32},"15",{"key":24,"text":297,"correct":22},"30",{"key":27,"text":113,"correct":22},{"key":30,"text":300,"correct":22},"60",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":20,"analysis":33},933776,"液化石油气储罐区宜布置在全年最小频率风向的（ ）。",[305,307,309,311],{"key":20,"text":306,"correct":32},"上风侧",{"key":24,"text":308,"correct":22},"下风侧",{"key":27,"text":310,"correct":22},"侧风向",{"key":30,"text":312,"correct":22},"上风或侧风向",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":30,"analysis":33},933777,"液体运输中，只有对闪点高及沸点在（ ）℃以上的可燃液体才用空气压送。",[317,319,320,322],{"key":20,"text":318,"correct":22},"35",{"key":24,"text":117,"correct":22},{"key":27,"text":321,"correct":22},"120",{"key":30,"text":323,"correct":32},"130",{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":27,"analysis":33},933778,"距石油化工生产装置的火炬筒（ ）m范围内严禁可燃气体防空。",[328,330,332,333],{"key":20,"text":329,"correct":22},"20",{"key":24,"text":331,"correct":22},"25",{"key":27,"text":297,"correct":32},{"key":30,"text":318,"correct":22},{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":27,"analysis":33},933779,"某石油化工企业的厂区设置有办公区、动力设备用房、消防站、甲类和乙类液体储罐组、装卸设施等。下列关于该化工企业总平面布置的做法中，正确的是（ ）。",[338,340,342,344],{"key":20,"text":339,"correct":22},"消防站布置在厂区全年最小频率风向的上风侧",{"key":24,"text":341,"correct":22},"液体罐组布置在办公区全年最小频率风向的下风侧",{"key":27,"text":343,"correct":32},"全厂性的高架火炬布置在生产区全年最小频率风向的上风侧",{"key":30,"text":345,"correct":22},"采用架空电力线路进出厂区的总变电所应布置在厂区中心",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":27,"analysis":33},933780,"全厂性火炬应布置在可燃气体的贮罐区、装卸区，以及全厂性重要辅助生产设施及人员集中场所的（ ）。",[350,352,353,355],{"key":20,"text":351,"correct":22},"全年最小频率风向的下风侧",{"key":24,"text":308,"correct":22},{"key":27,"text":354,"correct":32},"全年最小频率风向的上风侧",{"key":30,"text":306,"correct":22},{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":30,"analysis":33},933781,"常用可燃气体或蒸气的排放系统可以利用专门的设施，或利用通常的工艺管道和容器进行排放。大型的石油化工生产装置都是通过（ ）来排放易燃易爆气体的。",[360,362,364,366],{"key":20,"text":361,"correct":22},"泄压阀",{"key":24,"text":363,"correct":22},"防爆阀",{"key":27,"text":365,"correct":22},"放空管",{"key":30,"text":367,"correct":32},"火炬",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":30,"analysis":33},933782,"下列关于石油化工厂区内储罐区储罐防火的说法，错误的是（）。",[372,374,376,378],{"key":20,"text":373,"correct":22},"钢制储罐必须做防雷接地，接地点不应少于两处",{"key":24,"text":375,"correct":22},"钢质储罐接地点沿储罐周长的间距，不宜大于30m，接地电阻不宜大于10Ω",{"key":27,"text":377,"correct":22},"装有阻火器的地上卧式储罐的壁厚和地上固定顶钢质储罐的顶板厚度等于或大于4mm时，不应装设接闪杆（网）",{"key":30,"text":379,"correct":32},"外浮顶罐不应装设接闪杆（网），内浮顶罐应装设接闪杆（网），但应将浮顶与罐体用两根导线做电气连接",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":20,"analysis":33},933783,"下列关于可燃液体储罐布置的说法，不正确的是（ ）。",[384,386,388,390],{"key":20,"text":385,"correct":32},"在同一罐组内，单罐容积大于或等于1000m3时，火灾危险性类别不同的储罐不可同组布置",{"key":24,"text":387,"correct":22},"沸溢性液体的储罐不应与非沸溢性液体储罐同组布置",{"key":27,"text":389,"correct":22},"可燃液体的压力储罐可与液化烃的全压力储罐同组布置",{"key":30,"text":391,"correct":22},"可燃液体的低压储罐可与常压储罐同组布置",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":24,"analysis":33},933784,"下列关于石油化工企业室内消火栓设置的说法，不正确的是（ ）。",[396,398,400,402],{"key":20,"text":397,"correct":22},"单层甲、乙、丙类厂房（仓库）长度小于30m时，可不设室内消火栓系统",{"key":24,"text":399,"correct":32},"甲、乙类厂房（仓库），高层厂房及高架仓库的室内消火栓间距不应超过50m",{"key":27,"text":401,"correct":22},"消防竖管的管径不小于100mm，其接口应设在室外便于操作的地点",{"key":30,"text":403,"correct":22},"室内消火栓给水管网与自动喷水灭火系统的管网可引自同一消防给水系统，但应在报警阀前分开设置",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":30,"analysis":33},933785,"（ ）在容量相同的情况下，液体蒸发面对所储油料的体积之比值较小，能将储罐产生的应力均匀地分布在金属结构上，应力分布较为合理，能承受较高的压力。",[408,410,412,414],{"key":20,"text":409,"correct":22},"固定顶储罐",{"key":24,"text":411,"correct":22},"活动顶储罐",{"key":27,"text":413,"correct":22},"卧式储罐",{"key":30,"text":415,"correct":32},"特殊形状储罐",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":27,"analysis":33},933786,"下列关于公路油品装卸车场防火设计要求的说法，错误的是（ ）。",[420,422,424,426],{"key":20,"text":421,"correct":22},"装卸车场应布置在石油天然气站场、石油化工企业和石油库的边缘地带，并用围墙和其他区域隔开",{"key":24,"text":423,"correct":22},"装卸车场要设有单独的出入口和能保证消防车辆顺利接近火灾场地的消防车道",{"key":27,"text":425,"correct":32},"装卸车鹤管之间的距离，一般不小于6m",{"key":30,"text":427,"correct":22},"汽车装油鹤管与其装油泵房属同一操作单元，其间距可适当缩小",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":20,"analysis":33},933787,"某厂为满足生产要求，拟建设一个总储量为1500m3的液化石油气储罐区。所在地区的全年最小频率风向为东北风。在其他条件均满足规范要求的情况下，该储罐区宜布置在厂区的（ ）。",[432,434,436,438],{"key":20,"text":433,"correct":32},"东北侧",{"key":24,"text":435,"correct":22},"西北侧",{"key":27,"text":437,"correct":22},"西南侧",{"key":30,"text":439,"correct":22},"东南侧",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":24,"analysis":33},933788,"石油化工生产装置可以通过火炬排放易燃易爆气体，这要求在火炬筒周边（ ）m范围内严禁可燃气体放空。",[444,445,446,448],{"key":20,"text":329,"correct":22},{"key":24,"text":297,"correct":32},{"key":27,"text":447,"correct":22},"40",{"key":30,"text":113,"correct":22},{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":27,"analysis":33},933789,"石油化工企业内的液化石油气储罐（区）宜布置在地势平坦、开阔等不易积存液化石油气的地带，四周应设置高度不小于（ ）m的不燃烧体实体防护墙。",[453,455,457,459],{"key":20,"text":454,"correct":22},"2．0",{"key":24,"text":456,"correct":22},"0．5",{"key":27,"text":458,"correct":32},"1．0",{"key":30,"text":79,"correct":22},{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":24,"analysis":33},933790,"某地拟新建一座大型石油化工企业，该地的全年最小频率风向为东北风，全年最大频率风向为南风。则该企业宜布置在城镇的（ ），全厂性火炬宜布置在生产区的（ ）。",[464,466,468,470],{"key":20,"text":465,"correct":22},"西南侧，西南侧",{"key":24,"text":467,"correct":32},"东北侧，东北侧",{"key":27,"text":469,"correct":22},"西南侧，东北侧",{"key":30,"text":471,"correct":22},"东北侧，西南侧",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":30,"analysis":33},933791,"石油化工厂区内高架火炬（）m范围内，不应设置可燃气体放空。",[476,478,479,480],{"key":20,"text":477,"correct":22},"10",{"key":24,"text":295,"correct":22},{"key":27,"text":329,"correct":22},{"key":30,"text":297,"correct":32},{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":24,"analysis":33},933792,"油品装卸时严禁使用铁器敲击罐口，同时要控制油品流速，不应超过（ ）m／s。",[485,486,488,489],{"key":20,"text":67,"correct":22},{"key":24,"text":487,"correct":32},"4．5",{"key":27,"text":89,"correct":22},{"key":30,"text":490,"correct":22},"6",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":24,"analysis":33},933793,"下列关于全厂性的高架火炬总平面布置的说法，正确的是（ ）。",[495,497,499,501],{"key":20,"text":496,"correct":22},"全厂性的高架火炬宜位于厂房全年最小频率风向的上风侧",{"key":24,"text":498,"correct":32},"全厂性的高架火炬宜位于生产区全年最小频率风向的上风侧",{"key":27,"text":500,"correct":22},"全厂性的高架火炬宜位于厂房全年主导风向的下风侧",{"key":30,"text":502,"correct":22},"全厂性的高架火炬宜位于生产区全年主导风向的下风侧",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":30,"analysis":33},933794,"下列说法中，正确的是（ ）。",[507,509,511,513],{"key":20,"text":508,"correct":22},"在封闭的储罐内安装浮舱顶的储罐，又称为外浮顶罐",{"key":24,"text":510,"correct":22},"火炬系统是通过燃烧方式或冷却方式处理排放可燃气体的一种设施，其分为高架火炬、地面火炬",{"key":27,"text":512,"correct":22},"第一类全厂性重要设施指的是发生火灾时影响全厂生产的设施",{"key":30,"text":514,"correct":32},"区域性重要设施指的是发生火灾时影响部分装置生产或可能造成局部区域人身伤亡的设施",{"id":516,"libraryId":5,"type":15,"typeLabel":16,"stem":517,"options":518,"answer":20,"analysis":33},933795,"下列关于石油化工企业区域规划的说法，错误的是（ ）。",[519,521,523,525],{"key":20,"text":520,"correct":32},"公路和地区架空电力线路不宜穿越生产区",{"key":24,"text":522,"correct":22},"石油化工企业应采取防止泄漏的可燃液体和受污染的消防水排出厂外的措施",{"key":27,"text":524,"correct":22},"在山区或丘陵地区，石油化工企业的生产区应避免布置在窝风地带",{"key":30,"text":526,"correct":22},"石油化工企业的生产区宜位于邻近城镇或居民区全年最小频率风向的上风侧",{"id":528,"libraryId":5,"type":15,"typeLabel":16,"stem":529,"options":530,"answer":24,"analysis":33},933796,"下列关于石油化工企业消防站位置的选择，错误的是（ ）。",[531,533,535,537],{"key":20,"text":532,"correct":22},"企业消防站宜位于生产区全年最小频率风向的下风侧",{"key":24,"text":534,"correct":32},"企业消防站四周应交通便利并宜布置在工厂主要人流道路上",{"key":27,"text":536,"correct":22},"企业消防站应便于消防车迅速通往工艺装置区和罐区",{"key":30,"text":538,"correct":22},"企业消防站宜远离噪声场所",{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":27,"analysis":33},933797,"下列关于石油化工厂内铁路布置的说法，正确的是（ ）。",[543,545,547,549],{"key":20,"text":544,"correct":22},"厂内铁路为方便运输宜集中布置在厂区中心区域",{"key":24,"text":546,"correct":22},"当液化烃装卸栈台与可燃液体装卸栈台布置在同一装卸区时，液化烃栈台应布置在装卸区的两侧",{"key":27,"text":548,"correct":32},"可燃液体的铁路装卸线不得兼作走行线",{"key":30,"text":550,"correct":22},"工艺装置的固体产品铁路装卸线可布置在该装置的仓库或储存场（池）的中心区域",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":553,"options":554,"answer":20,"analysis":33},933798,"可燃液体地上固定顶罐组的总容积不应大于（ ）m3。",[555,557,559,561],{"key":20,"text":556,"correct":32},"120000",{"key":24,"text":558,"correct":22},"600000",{"key":27,"text":560,"correct":22},"240000",{"key":30,"text":562,"correct":22},"320000",{"id":564,"libraryId":5,"type":15,"typeLabel":16,"stem":565,"options":566,"answer":20,"analysis":33},933799,"下列关于防火堤及隔堤设置的说法，错误的是（ ）。",[567,569,571,573],{"key":20,"text":568,"correct":32},"隔堤所分隔的沸溢性液体储罐不应超过4个",{"key":24,"text":570,"correct":22},"立式储罐至防火堤内堤脚线的距离不应小于罐壁高度的一半",{"key":27,"text":572,"correct":22},"卧式储罐至防火堤内堤脚线的距离不应小于3m",{"key":30,"text":574,"correct":22},"相邻罐组防火堤的外堤脚线之间应留有宽度不小于7m的消防空地",{"id":576,"libraryId":5,"type":15,"typeLabel":16,"stem":577,"options":578,"answer":30,"analysis":33},933800,"甲、乙类装置区周围和罐组四周道路边应设置手动火灾报警按钮，其间距不宜大于（ ）m。",[579,580,581,583],{"key":20,"text":297,"correct":22},{"key":24,"text":113,"correct":22},{"key":27,"text":582,"correct":22},"80",{"key":30,"text":117,"correct":32},{"id":585,"libraryId":5,"type":15,"typeLabel":16,"stem":586,"options":587,"answer":30,"analysis":33},933801,"某一油罐区，内部设有2个2000m3、1个5000m3的汽油罐，罐径分别为10m、15m，储罐采用固定顶形式，罐组内相邻储罐的防火间距应不小于（ ）m。",[588,589,590,592],{"key":20,"text":89,"correct":22},{"key":24,"text":490,"correct":22},{"key":27,"text":591,"correct":22},"7．5",{"key":30,"text":593,"correct":32},"9",{"id":595,"libraryId":5,"type":15,"typeLabel":16,"stem":596,"options":597,"answer":24,"analysis":33},933802,"下列关于罐区防火设计要求说法错误的是（ ）。",[598,600,602,604],{"key":20,"text":599,"correct":22},"甲、乙、丙类液体储罐区，应布置在城市（区域）的边缘或相对独立的安全地带",{"key":24,"text":601,"correct":32},"可燃、助燃气体储罐区和可燃材料堆场等，宜布置在城市（区域）全年最小频率风向的下风侧",{"key":27,"text":603,"correct":22},"甲、乙、丙类液体储罐（区）宜布置在地势较低的地带",{"key":30,"text":605,"correct":22},"液化石油气储罐（区）宜布置在地势平坦、开阔等不易积存液化石油气的地带",{"id":607,"libraryId":5,"type":15,"typeLabel":16,"stem":608,"options":609,"answer":20,"analysis":33},933803,"放空管一般应设在设备或容器的顶部。间歇排放的放空管口应高出（ ）m范围内的平台或建筑物顶3．5m以上。",[610,611,612,613],{"key":20,"text":477,"correct":32},{"key":24,"text":329,"correct":22},{"key":27,"text":297,"correct":22},{"key":30,"text":447,"correct":22},{"id":615,"libraryId":5,"type":15,"typeLabel":16,"stem":616,"options":617,"answer":20,"analysis":33},933804,"工艺装置内露天布置的塔、容器等，当顶板厚度等于或大于（ ）mm时，可不设避雷针。",[618,619,620,622],{"key":20,"text":69,"correct":32},{"key":24,"text":490,"correct":22},{"key":27,"text":621,"correct":22},"8",{"key":30,"text":477,"correct":22},[624,627,630,633,636,639],{"id":15,"name":625,"category":7,"favorite":626},"领导干部任职前廉政法规知识测试题",92,{"id":628,"name":629,"category":7,"favorite":15},595,"建筑结构与设备",{"id":631,"name":632,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":634,"name":635,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":637,"name":638,"category":7,"favorite":8},534,"BIM工程师",{"id":640,"name":638,"category":7,"favorite":8},535]