[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-41":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":626},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,41,50,2960,[13,34,46,58,70,82,94,106,118,130,142,153,165,177,188,197,209,221,233,241,259,274,289,304,318,333,345,357,369,381,391,403,415,427,439,451,461,473,485,497,509,521,530,542,554,566,578,590,602,614],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},933705,1,"单选题","根据《消防给水及消火栓系统技术规范》GB50974—2014的规定，下列关于不同场所消火栓系统火灾延续时间的说法，不正确的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","建筑高度为34m的丁类厂房，其火灾延续时间不应小于2．0h",false,{"key":24,"text":25,"correct":26},"B","建筑面积为2000m2的人防工程，其火灾延续时间不应小于2．0h",true,{"key":28,"text":29,"correct":22},"C","建筑高度为54m的住宅，其火灾延续时间不应小于2．0h",{"key":31,"text":32,"correct":22},"D","建筑高度为50m的综合楼，其火灾延续时间不应小于3．0h","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},933706,"根据《消防给水及消火栓系统技术规范》GB50974—2014的规定，下列场所不需要设置消防水泵接合器的是（）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"占地面积为1000m2的5层丁类厂房",{"key":24,"text":41,"correct":22},"建筑高度为18m，每层建筑面积为1200m2的4层展览建筑",{"key":28,"text":43,"correct":22},"建筑高度为33m的住宅",{"key":31,"text":45,"correct":26},"建筑高度为22m，每层建筑面积为500m2的5层宾馆",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},933707,"某高层公共建筑，室外消火栓的设计流量为40L／s，下列关于该建筑室外消火栓的做法（不考虑市政消火栓），不正确的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"建筑东南西北四个方向分别设置1个室外消火栓",{"key":24,"text":53,"correct":22},"采用进水口公称通径为DN150的室外消火栓",{"key":28,"text":55,"correct":22},"室外地上式消火栓设有一个直径为100mm和两个直径为65mm的栓口",{"key":31,"text":57,"correct":22},"室外消火栓距离建筑外墙的距离为7m",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},933708,"下列关于消防水泵的说法中错误的是（）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"当采用离心泵时，水泵启动时其叶轮必须浸没在水中",{"key":24,"text":65,"correct":22},"为保证消防水泵及时、可靠地启动，吸水管应采用自灌式吸水",{"key":28,"text":67,"correct":26},"消防水泵的吸水管变径时，可采用同心异径管",{"key":31,"text":69,"correct":22},"消防水泵吸水口的淹没深度应满足消防水泵在最低水位运行安全的要求",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},933709,"某消防水泵房内设有3台消防水泵，每台消防水泵出水管上应设置（ ）的试水管，并应采取排水措施。",[74,76,78,80],{"key":20,"text":75,"correct":22},"DN50",{"key":24,"text":77,"correct":26},"DN65",{"key":28,"text":79,"correct":22},"DN80",{"key":31,"text":81,"correct":22},"DN100",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},933710,"某综合楼为 60m 的一类公建，室内外消火栓设计流量及湿式自喷设计流量均为 40L\u002Fs，当消防水池采用一路供水，且火灾延续时间内补水 50 立方米，该建筑 40m 范围内有枝状布置的市政消火栓 3 套，消防水池的有效容积为（ ）立方米。",[86,88,90,92],{"key":20,"text":87,"correct":26},"846",{"key":24,"text":89,"correct":22},"472",{"key":28,"text":91,"correct":22},"954",{"key":31,"text":93,"correct":22},"1008",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},933711,"某高层公共建筑，设置由高位消防水箱稳压的临时高压系统，消防水泵和消防水池均设在地下一层，高位消防水箱最低水位与最不利点消火栓的高差为 8m，与地下室消火栓高差为 42m，消防水泵吸水口与消防水池最高水位之间的高差为 2m，消防水泵零流量时扬程为 120m，该给水系统工作压力为（ ）MPa。",[98,100,102,104],{"key":20,"text":99,"correct":22},"1.2",{"key":24,"text":101,"correct":26},"1.22",{"key":28,"text":103,"correct":22},"1.62",{"key":31,"text":105,"correct":22},"1.28",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":28,"analysis":33},933712,"某综合楼建筑，高度 59m，采用临时高压消防给水系统。建筑中设有一个总建筑面积为 35000 平方米的百货商场，则该综合楼的高位消防水箱的有效容积不应小于（ ）立方米。",[110,112,114,116],{"key":20,"text":111,"correct":22},"18",{"key":24,"text":113,"correct":22},"36",{"key":28,"text":115,"correct":26},"50",{"key":31,"text":117,"correct":22},"100",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":20,"analysis":33},933713,"下列建筑中可仅采用 1 支消防水枪的 1 股充实水柱到达室内任何部位即可满足规范要求的是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":26},"三层钢构件仓库，长 15m，宽 12m，高 22m",{"key":24,"text":125,"correct":22},"高度 57m 住宅，每单元设置了一部疏散楼梯",{"key":28,"text":127,"correct":22},"高度 23m 办公楼，长 12m，宽 10m",{"key":31,"text":129,"correct":22},"人防工程中体积为 1200m3的影院",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},933714,"市政消火栓或消防车从消防水池吸水向建筑物供应室外消防用水时，下列说法不符合规范要求的是（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"室外消防水池的每个取水口宜按一个室外消火栓计算,且其保护半径不应大于150m",{"key":24,"text":137,"correct":26},"为消防水泵结合器供水时,距建筑外缘5m~150m 范围的市政消火栓可计入室外消火栓的数量",{"key":28,"text":139,"correct":22},"当市政给水管网为环状时,满足距离要求的市政消火栓出流量宜计入建筑室外消火栓设计流量",{"key":31,"text":141,"correct":22},"当市政给水管网为枝状,且满足距离要求,计入建筑室外消火栓设计流量的不宜超过 1 个市政消火栓的出流量",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":20,"analysis":33},933715,"室内消火栓的布置间距应由计算确定，对于消火栓按1支消防水枪的1股充实水柱布置的建筑物，消火栓的布置间距不应大于（ ）m。",[146,147,149,151],{"key":20,"text":115,"correct":26},{"key":24,"text":148,"correct":22},"40",{"key":28,"text":150,"correct":22},"30",{"key":31,"text":152,"correct":22},"20",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":28,"analysis":33},933716,"当消防水池的有效总容积大于2000m3时，其补水时间不应大于（ ）。",[157,159,161,163],{"key":20,"text":158,"correct":22},"48h",{"key":24,"text":160,"correct":22},"72h",{"key":28,"text":162,"correct":26},"96h",{"key":31,"text":164,"correct":22},"118h",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":20,"analysis":33},933717,"高层建筑室内消火栓给水系统的给水方式包括（ ）。",[169,171,173,175],{"key":20,"text":170,"correct":26},"分区消防给水方式",{"key":24,"text":172,"correct":22},"直接给水方式",{"key":28,"text":174,"correct":22},"设有消防水箱的给水方式",{"key":31,"text":176,"correct":22},"设有水泵和消防水箱给水方式",{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":31,"analysis":33},933718,"同一建筑物内应采用统一规格的消火栓、水枪和水带，其中每根水带的长度不应超过（ ）m。",[181,183,185,186],{"key":20,"text":182,"correct":22},"10",{"key":24,"text":184,"correct":22},"15",{"key":28,"text":152,"correct":22},{"key":31,"text":187,"correct":26},"25",{"id":189,"libraryId":5,"type":15,"typeLabel":16,"stem":190,"options":191,"answer":28,"analysis":33},933719,"建筑高度为88m的办公建筑的高位消防水箱储水量应不小于（ ）m3。",[192,194,195,196],{"key":20,"text":193,"correct":22},"12",{"key":24,"text":111,"correct":22},{"key":28,"text":113,"correct":26},{"key":31,"text":115,"correct":22},{"id":198,"libraryId":5,"type":15,"typeLabel":16,"stem":199,"options":200,"answer":20,"analysis":33},933720,"水泵接合器的位置应该在距室外消火栓或消防水池（ ）m范围内。",[201,203,205,207],{"key":20,"text":202,"correct":26},"15～40",{"key":24,"text":204,"correct":22},"25～50",{"key":28,"text":206,"correct":22},"10～25",{"key":31,"text":208,"correct":22},"5～150",{"id":210,"libraryId":5,"type":15,"typeLabel":16,"stem":211,"options":212,"answer":31,"analysis":33},933721,"下列关于室外消火栓的设置要求说法错误的是（ ）。",[213,215,217,219],{"key":20,"text":214,"correct":22},"室外消火栓应沿道路设置，当道路宽度大于60m时，宜在道路两侧交叉错落设置消火栓，并宜靠近十字路口",{"key":24,"text":216,"correct":22},"室外消火栓的间距不应大于120m",{"key":28,"text":218,"correct":22},"消火栓距路边不应大于2m，距房屋外墙不宜小于5m",{"key":31,"text":220,"correct":26},"室外消火栓宜集中布置在建筑一侧",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":31,"analysis":33},933722,"下列可以不设置室外消防给水系统的是（ ）。",[225,227,229,231],{"key":20,"text":226,"correct":22},"居住区人数1000人",{"key":24,"text":228,"correct":22},"耐火等级为三级",{"key":28,"text":230,"correct":22},"建筑物体积大于3000m3的戊类厂房",{"key":31,"text":232,"correct":26},"居住区人数不超过500人且建筑物层数不超过两层的居住区",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":28,"analysis":33},933723,"某采用临时高压消防给水系统的商场，地上7层，建筑高度28m，每层平面尺寸为30m×80m，在对高位消防水箱进行选取时，其有效容积不应小于（ ）m3。",[237,238,239,240],{"key":20,"text":193,"correct":22},{"key":24,"text":111,"correct":22},{"key":28,"text":113,"correct":26},{"key":31,"text":115,"correct":22},{"id":242,"libraryId":5,"type":243,"typeLabel":244,"stem":245,"options":246,"answer":258,"analysis":33},933724,2,"多选题","根据《消防给水及消火栓系统技术规范》GB50974—2014，关于消防水泵房设计规定，下列说法不正确的有（ ）。",[247,249,251,253,255],{"key":20,"text":248,"correct":26},"寒冷地区无人值守的消防水泵房采暖温度不应低于3℃",{"key":24,"text":250,"correct":22},"消防水泵房的通风宜按6次／h设计",{"key":28,"text":252,"correct":26},"附设在建筑物内的消防水泵房，开向疏散走道的门应采用乙级防火门",{"key":31,"text":254,"correct":22},"消防水泵房应设置排水设施",{"key":256,"text":257,"correct":26},"E","附设在建筑物内的消防水泵房，不应设置在地下二层及以下楼层","ACE",{"id":260,"libraryId":5,"type":243,"typeLabel":244,"stem":261,"options":262,"answer":273,"analysis":33},933725,"下列建筑中应设置消防软管卷盘或轻便消防水龙的有（ ）。",[263,265,267,269,271],{"key":20,"text":264,"correct":26},"住宅建筑首层的商业服务网点，建筑面积260m2",{"key":24,"text":266,"correct":26},"综合办公楼，地上30层，层高4m",{"key":28,"text":268,"correct":22},"建筑高度62m的办公楼，每层建筑面积3200m2",{"key":31,"text":270,"correct":26},"24m的医院门诊楼，每层建筑面积1200m2",{"key":256,"text":272,"correct":22},"建筑高度为27m的住宅建筑，每层建筑面积530m2","ABD",{"id":275,"libraryId":5,"type":243,"typeLabel":244,"stem":276,"options":277,"answer":288,"analysis":33},933726,"下列（ ）场所的消火栓系统应设置水泵接合器。",[278,280,282,284,286],{"key":20,"text":279,"correct":26},"高层民用建筑",{"key":24,"text":281,"correct":22},"地下两层的公共建筑",{"key":28,"text":283,"correct":26},"高层工业建筑",{"key":31,"text":285,"correct":22},"四层的多层工业建筑",{"key":256,"text":287,"correct":22},"四层的多层公共建筑","AC",{"id":290,"libraryId":5,"type":243,"typeLabel":244,"stem":291,"options":292,"answer":303,"analysis":33},933727,"下列关于消防给水设施的说法不正确的是（ ）。",[293,295,297,299,301],{"key":20,"text":294,"correct":22},"消防水泵直接从市政管网直接吸水时，应在消防水泵出水管上设置有空气隔断的倒流防止器",{"key":24,"text":296,"correct":26},"消防水泵吸水管布置应避免形成气囊，吸水管变径连接时采用的同心异径管必须采用管顶平接",{"key":28,"text":298,"correct":26},"环状管道应采用阀门分成若干独立段，每段内室外消火栓的数量不宜超过 3 个",{"key":31,"text":300,"correct":22},"消防给水系统管网的正常泄漏量应根据管道材质、接口形式等确定，当没有管网泄漏量数据时，稳压泵的设计流量宜按消防给水设计流量的 1%~3%计，且不宜小于1L\u002Fs",{"key":256,"text":302,"correct":26},"稳压泵吸水管应设置消声止回阀和明杆闸阀，稳压泵出水管应设置明杆闸阀","BCE",{"id":305,"libraryId":5,"type":243,"typeLabel":244,"stem":306,"options":307,"answer":258,"analysis":33},933728,"下列关于串联分区供水的说法，正确的有（ ）。",[308,310,312,314,316],{"key":20,"text":309,"correct":26},"转输水箱可以兼做高位水箱，有效储水容积不应小于 60m3",{"key":24,"text":311,"correct":22},"串联分区宜采用直接串联的方式",{"key":28,"text":313,"correct":26},"直接串联时，应先启动低区消防水泵，再启动高区消防水泵",{"key":31,"text":315,"correct":22},"采用转输水箱间接串联时，应先启动转输泵，再启动高区泵",{"key":256,"text":317,"correct":26},"转输水箱的溢流管宜接至消防水池",{"id":319,"libraryId":5,"type":243,"typeLabel":244,"stem":320,"options":321,"answer":332,"analysis":33},933729,"以下关于消防给水系统管网、管道管径说法正确的有（ ）。",[322,324,326,328,330],{"key":20,"text":323,"correct":22},"某城镇人口 10 万人，市政消火栓采用环状给水管网，管径为 DN100",{"key":24,"text":325,"correct":26},"某北方城市消防水鹤管径为 DN200",{"key":28,"text":327,"correct":26},"室内消火栓管径应计算确定，且不应小于DN100",{"key":31,"text":329,"correct":26},"消防水池进水管管径应经计算确定，最小不应小于DN100",{"key":256,"text":331,"correct":22},"高位消防水箱进水管应满足 8h 补水要求，管径不应小于 DN36","BCD",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":24,"analysis":33},933730,"下列选项中，不属于消防通信设施的是（ ）。",[337,339,341,343],{"key":20,"text":338,"correct":22},"火灾事故广播系统",{"key":24,"text":340,"correct":26},"声光警报器",{"key":28,"text":342,"correct":22},"消防专用电话系统",{"key":31,"text":344,"correct":22},"消防电话插孔",{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":24,"analysis":33},933731,"某采用临时高压消防给水系统的建筑设有两台消防水泵，设计流量分别为15L／s和30L／s，则该建筑在选用备用泵时流量不应低于（ ）。",[349,351,353,355],{"key":20,"text":350,"correct":22},"10L／s",{"key":24,"text":352,"correct":26},"30L／s",{"key":28,"text":354,"correct":22},"15L／s",{"key":31,"text":356,"correct":22},"25L／s",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":24,"analysis":33},933732,"根据《消防给水及消火栓系统技术规范》（GB50974--2014）的规定，下列建筑应设备用泵的是（ ）。",[361,363,365,367],{"key":20,"text":362,"correct":22},"建筑高度为53m的住宅",{"key":24,"text":364,"correct":26},"建筑高度为51m的办公楼",{"key":28,"text":366,"correct":22},"室外消防给水设计流量为25L／s的单层图书馆",{"key":31,"text":368,"correct":22},"容纳900人的中型剧场",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":24,"analysis":33},933733,"某建筑底部设有消防水池，为保证消防水泵在最低水位时运行安全，在吸水口设有旋流防止器，则该旋流防止器的淹没深度不应小于（ ）。",[373,375,377,379],{"key":20,"text":374,"correct":22},"100mm",{"key":24,"text":376,"correct":26},"200mm",{"key":28,"text":378,"correct":22},"300mm",{"key":31,"text":380,"correct":22},"600mm",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":31,"analysis":33},933734,"消防水泵的供电应符合现行国家标准《供配电系统设计规范》（GB50052--2009）的要求，消防水泵双电源切换时，一路电源与柴油发电机的切换时间不应大于（ ）s。",[385,387,389,390],{"key":20,"text":386,"correct":22},"2",{"key":24,"text":388,"correct":22},"5",{"key":28,"text":182,"correct":22},{"key":31,"text":184,"correct":26},{"id":392,"libraryId":5,"type":15,"typeLabel":16,"stem":393,"options":394,"answer":20,"analysis":33},933735,"下列有关稳压泵选取的说法，错误的是（ ）。",[395,397,399,401],{"key":20,"text":396,"correct":26},"稳压泵一般选用大流量、高扬程的水泵",{"key":24,"text":398,"correct":22},"稳压泵宜采用离心泵，泵外壳和叶轮等主要部件的材质宜采用不锈钢",{"key":28,"text":400,"correct":22},"稳压泵的设计压力需要满足系统自动启动和管网充满水的要求",{"key":31,"text":402,"correct":22},"稳压泵的设计流量应满足消防给水系统管网的正常泄漏量和系统自动启动流量",{"id":404,"libraryId":5,"type":15,"typeLabel":16,"stem":405,"options":406,"answer":28,"analysis":33},933736,"下列关于消防水池的说法，错误的是（ ）。",[407,409,411,413],{"key":20,"text":408,"correct":22},"消防水池应设置就地水位显示装置，并应在消防控制中心或值班室等地点设置显示消防水池水位的装置",{"key":24,"text":410,"correct":22},"消防用水与其他用水合用时，消防水池应有保证消防用水不被他用的技术措施",{"key":28,"text":412,"correct":26},"消防水池的总蓄水有效容积大于1000m3时，宜设两格能独立使用的消防水池",{"key":31,"text":414,"correct":22},"消防水池进水管应根据其有效容积和补水时间确定，补水时间不宜大于48h",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":31,"analysis":33},933737,"下列关于建筑设置高位消防水箱有效容积的说法，错误的是（ ）。",[419,421,423,425],{"key":20,"text":420,"correct":22},"建筑高度为55m的办公楼，高位消防水箱的有效容积不应小于36m3",{"key":24,"text":422,"correct":22},"建筑高度为27m的医院住院部，高位消防水箱的有效容积不应小于36m3",{"key":28,"text":424,"correct":22},"建筑高度为25m的邮政大楼，高位消防水箱的有效容积不应小于18m3",{"key":31,"text":426,"correct":26},"首层为商业服务网点的住宅建筑，建筑高度为25m，高位消防水箱的有效容积不应小于12m3",{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":20,"analysis":33},933738,"高位消防水箱的进水管管径应满足消防水箱（ ）h充满水的要求，但管径不应小于DN（ ）。",[431,433,435,437],{"key":20,"text":432,"correct":26},"8，32",{"key":24,"text":434,"correct":22},"8，100",{"key":28,"text":436,"correct":22},"24，32",{"key":31,"text":438,"correct":22},"24，100",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":20,"analysis":33},933739,"下列关于消防水泵接合器设置要求的说法，错误的是（ ）。",[443,445,447,449],{"key":20,"text":444,"correct":26},"墙壁消防水泵接合器的安装高度距地面宜为1．10m",{"key":24,"text":446,"correct":22},"水泵接合器处应设置永久性标志铭牌，并应标明供水系统、供水范围和额定压力",{"key":28,"text":448,"correct":22},"墙壁消防水泵接合器与墙面上的门、窗、孔、洞的净距离不应小于2m，且不应安装在玻璃幕墙下方",{"key":31,"text":450,"correct":22},"水泵接合器应设在室外便于消防车使用的地点",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":28,"analysis":33},933740,"高位消防水箱的最低有效水位应根据出水管喇叭口和防止旋流器的淹没深度确定，当采用防止旋流器时最低有效水位的保护高度不应小于（ ）mm。",[455,456,457,459],{"key":20,"text":115,"correct":22},{"key":24,"text":117,"correct":22},{"key":28,"text":458,"correct":26},"150",{"key":31,"text":460,"correct":22},"200",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":24,"analysis":33},933741,"某高层综合楼，室内、外消火栓的设计流量均为20L／s，自动喷水灭火系统的设计流量为15L／s。市政给水管网能够保证室外消防用水，消防水池储存室内消火栓和自动喷水灭火系统的用水量，消防水池有符合要求的补水措施，两路补水量均为30m3／h。该建筑消防水池的最小有效容积为（ ）m3。",[465,467,469,471],{"key":20,"text":466,"correct":22},"104",{"key":24,"text":468,"correct":26},"180",{"key":28,"text":470,"correct":22},"240",{"key":31,"text":472,"correct":22},"270",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":28,"analysis":33},933742,"当工艺装置区、储罐区、堆场等构筑物采用临时高压消防给水系统时，室外消火栓宜配置（ ）。",[477,479,481,483],{"key":20,"text":478,"correct":22},"消防水带和轻便水龙",{"key":24,"text":480,"correct":22},"消防水带和消防软管卷盘",{"key":28,"text":482,"correct":26},"消防水带和消防水枪",{"key":31,"text":484,"correct":22},"消防水枪和轻便水龙",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":20,"analysis":33},933743,"某建筑采用临时高压消防给水系统供水，室内消火栓系统的设计流量为30L／s，设计扬程为0．9MPa。下列关于该系统消防水泵的做法中，正确的是（ ）。",[489,491,493,495],{"key":20,"text":490,"correct":26},"消防水泵的吸水管喇叭口在消防水池内最低有效水位下的淹没深度为1000mm",{"key":24,"text":492,"correct":22},"消防水泵零流量时的压力为1．4MPa",{"key":28,"text":494,"correct":22},"消防水泵从市政管网直接抽水，在水泵出水管上设置有旋流防止器",{"key":31,"text":496,"correct":22},"消防水泵的出流量达到45L／s时，水泵出口的压力为0．45MPa",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":31,"analysis":33},933744,"下列场所或建筑中，应设置室内消火栓系统的是（ ）。",[501,503,505,507],{"key":20,"text":502,"correct":22},"占地面积为300m2的丙类厂房",{"key":24,"text":504,"correct":22},"体积为5000m3的单层图书馆",{"key":28,"text":506,"correct":22},"设有1000个座位的单层礼堂",{"key":31,"text":508,"correct":26},"建筑高度为16m的多层教学楼",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":28,"analysis":33},933745,"某公共建筑高度为43m，总建筑面积为10000m2，顶部设有高位消防水箱，建筑内设有自动喷水灭火系统和消火栓系统，为满足最不利点灭火设备的水压要求，在该建筑顶部设了增稳压装置。下列有关该建筑灭火设备最不利点处静水压力的说法，正确的是（ ）。",[513,515,517,519],{"key":20,"text":514,"correct":22},"消火栓系统管网最低点静水压力为0．1MPa",{"key":24,"text":516,"correct":22},"自动喷水灭火系统喷头静水压力为0．12MPa",{"key":28,"text":518,"correct":26},"消火栓系统管网最不利点处的静水压力为0．16MPa",{"key":31,"text":520,"correct":22},"自动喷水灭火系统喷头最不利点处的静水压力为0．07MPa",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":28,"analysis":33},933746,"某建筑采用消防水泵转输水箱串联方式分区供水，根据规定转输水箱的有效容积不应小于（ ）m3。",[525,526,527,529],{"key":20,"text":111,"correct":22},{"key":24,"text":113,"correct":22},{"key":28,"text":528,"correct":26},"60",{"key":31,"text":117,"correct":22},{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":28,"analysis":33},933747,"某公共建筑，消防水池的有效容积为850m3。下列关于该消防水池的说法中，错误的是（ ）。",[534,536,538,540],{"key":20,"text":535,"correct":22},"消防水池补水时间不宜大于48h",{"key":24,"text":537,"correct":22},"宜设置两格能独立使用的消防水池",{"key":28,"text":539,"correct":26},"消防水池溢流管采用直接排水方式",{"key":31,"text":541,"correct":22},"消防水池应设置就地水位显示装置",{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":544,"options":545,"answer":31,"analysis":33},933748,"下列关于消防软管卷盘和轻便水龙的说法，正确的是（ ）。",[546,548,550,552],{"key":20,"text":547,"correct":22},"消防软管卷盘的长度宜为25m",{"key":24,"text":549,"correct":22},"消防软管卷盘和轻便水龙应配置当量喷嘴直径为11mm的消防水枪",{"key":28,"text":551,"correct":22},"轻便水龙应配置公称直径19mm有内衬里的消防水带",{"key":31,"text":553,"correct":26},"消防软管卷盘和轻便水龙的用水量可不计入消防用水总量",{"id":555,"libraryId":5,"type":15,"typeLabel":16,"stem":556,"options":557,"answer":31,"analysis":33},933749,"下列关于室内消火栓设置要求的说法，错误的是（ ）。",[558,560,562,564],{"key":20,"text":559,"correct":22},"消火栓按2支消防水枪的2股充实水柱布置的建筑物，消火栓的布置间距不应大于30．0m",{"key":24,"text":561,"correct":22},"消火栓按1支消防水枪的1股充实水柱布置的建筑物，消火栓的布置间距不应大于50．0m",{"key":28,"text":563,"correct":22},"设有室内消火栓的建筑应设置带有压力表的试验消火栓",{"key":31,"text":565,"correct":26},"消防电梯前室应设置室内消火栓，该消火栓不应计入消火栓使用数量",{"id":567,"libraryId":5,"type":15,"typeLabel":16,"stem":568,"options":569,"answer":31,"analysis":33},933750,"下列建筑中，可采用一支消防水枪的是（ ）。",[570,572,574,576],{"key":20,"text":571,"correct":22},"5层仓库，每层建筑面积为500m2，层高为4m",{"key":24,"text":573,"correct":22},"4层厂房，每层建筑面积为1000m2，层高为5m",{"key":28,"text":575,"correct":22},"3层厂房，每层建筑面积为1200m2，层高为7m",{"key":31,"text":577,"correct":26},"2层仓库，每层建筑面积为400m2，层高为6m",{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":580,"options":581,"answer":20,"analysis":33},933751,"下列关于室外消防给水管道敷设的说法，错误的是（ ）。",[582,584,586,588],{"key":20,"text":583,"correct":26},"室外消防给水管道在布置成枝状的同时应合理设置阀门",{"key":24,"text":585,"correct":22},"室外消防给水管道的阀门宜采用耐腐蚀的明杆闸阀，设置的位置可用以控制两路水源，能保证管网中某一管段维修或发生故障时其余管段仍能保证消防用水量和水压的要求",{"key":28,"text":587,"correct":22},"当室内消防给水系统和室外消防给水系统管道合并设置的稳高压消防给水系统时，其管道应根据土质和管道荷载的情况，合理确定管道基础的做法",{"key":31,"text":589,"correct":22},"消防给水系统管道的最高点处宜设置自动排气阀",{"id":591,"libraryId":5,"type":15,"typeLabel":16,"stem":592,"options":593,"answer":28,"analysis":33},933752,"关于室内消防给水管道设置的说法，错误的是（ ）。",[594,596,598,600],{"key":20,"text":595,"correct":22},"室内消火栓竖管管径不应小于DN100",{"key":24,"text":597,"correct":22},"每根竖管与供水横干管相接处应设置阀门",{"key":28,"text":599,"correct":26},"当室外消火栓设计流量不大于20L／s，且室内消火栓不超过10个时，室内消火栓系统管网应布置成环状",{"key":31,"text":601,"correct":22},"合用消防泵时，供水管路沿水流方向应在报警阀前分开设置",{"id":603,"libraryId":5,"type":15,"typeLabel":16,"stem":604,"options":605,"answer":20,"analysis":33},933753,"下列建筑中，可不设置室内消火栓给水系统的是（ ）。",[606,608,610,612],{"key":20,"text":607,"correct":26},"耐火等级为二级，占地面积为2000 m2的单层自行车装配厂房",{"key":24,"text":609,"correct":22},"耐火等级为二级，建筑高度为16m的中学教学楼",{"key":28,"text":611,"correct":22},"耐火等级为一级，设置1500个座位的某企业礼堂",{"key":31,"text":613,"correct":22},"耐火等级为二级、建筑高度为27m的住宅建筑",{"id":615,"libraryId":5,"type":15,"typeLabel":16,"stem":616,"options":617,"answer":31,"analysis":33},933754,"下列建筑需要设置备用消防水泵的是（）。",[618,620,622,624],{"key":20,"text":619,"correct":22},"室外消防给水设计流量为25L／s的高层旅馆",{"key":24,"text":621,"correct":22},"室外消防给水设计流量为15L／s的多层商店",{"key":28,"text":623,"correct":22},"室内消防给水设计流量为10L／s的多层电影院",{"key":31,"text":625,"correct":26},"建筑高度为55m的住宅",[627,630,633,636,639,642],{"id":15,"name":628,"category":7,"favorite":629},"领导干部任职前廉政法规知识测试题",92,{"id":631,"name":632,"category":7,"favorite":15},595,"建筑结构与设备",{"id":634,"name":635,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":637,"name":638,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":640,"name":641,"category":7,"favorite":8},534,"BIM工程师",{"id":643,"name":641,"category":7,"favorite":8},535]