[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-40":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":604},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,40,50,2960,[13,34,46,58,70,82,94,106,124,136,148,160,172,184,196,208,220,232,244,256,268,280,292,303,315,326,336,346,358,370,378,390,399,411,423,432,444,456,468,480,492,504,516,528,537,549,558,568,580,592],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},933655,1,"单选题","下列场所的消防用电应按一级负荷供电的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","室外消防用水量大于30L／s的厂房（仓库）",false,{"key":24,"text":25,"correct":26},"B","建筑高度大于50m的乙、丙类生产厂房",true,{"key":28,"text":29,"correct":22},"C","室外消防用水量大于35L／s的可燃材料堆场",{"key":31,"text":32,"correct":22},"D","座位数超过3000个的体育馆","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},933656,"某建筑消防用电按一级负荷供电，下列供电方式不能视为一级负荷供电的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"建筑一路电源来自一个区域变电站，同时设置一台自备发电机组",{"key":24,"text":41,"correct":26},"建筑两路电源来自同一个区域变电站",{"key":28,"text":43,"correct":22},"建筑电源来自两个不同的发电厂",{"key":31,"text":45,"correct":22},"建筑电源来自两个区域变电站",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},933657,"下列关于厂房仓库消防供电负荷等级选取的说法，错误的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"建筑高度为60m的丙类厂房应采用一级消防负荷供电",{"key":24,"text":53,"correct":22},"建筑高度为52m的丙类库房应采用一级消防负荷供电",{"key":28,"text":55,"correct":22},"建筑高度为52m的乙类厂房应采用一级消防负荷供电",{"key":31,"text":57,"correct":26},"建筑高度为60m的戊类厂房应采用一级消防负荷供电",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},933658,"下列建筑中，消防用电应按一级负荷供电的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"建筑高度为25m的医院",{"key":24,"text":65,"correct":22},"建筑高度为54m的住宅建筑",{"key":28,"text":67,"correct":22},"建筑高度为50m的写字楼",{"key":31,"text":69,"correct":22},"建筑高度为14m的2层礼堂",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},933659,"下列关于一级负荷和二级负荷的电源供电方式的说法，错误的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"一级负荷应由两个电源供电，且两个电源之间无联系",{"key":24,"text":77,"correct":22},"二级负荷的供电系统宜采用两回线路供电",{"key":28,"text":79,"correct":26},"二级负荷的供电系统在负荷较小或地区供电条件较困难的条件下，允许有一回10kV以上专线架空线或电缆供电",{"key":31,"text":81,"correct":22},"一级负荷应由两个电源供电，且两个电源有直接联系时，任一电源发生故障，两个电源的任何部分均不会同时损坏",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":28,"analysis":33},933660,"当采用柴油发电机组作消防备用电源时，下列说法中正确的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"供电半径大于400m时，宜采用低压柴油发电机组",{"key":24,"text":89,"correct":22},"供电半径不大于400m时，宜采用中压柴油发电机组",{"key":28,"text":91,"correct":26},"线路电压降应不大于供电电压的5％",{"key":31,"text":93,"correct":22},"线路电压降应不大于供电电压的10％",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},933661,"下列建筑及设施中消防用电负荷应按二级负荷供电的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":26},"首层建筑面积 4000 ㎡的四层商业楼",{"key":24,"text":101,"correct":22},"建筑高度为 55m 的住宅建筑",{"key":28,"text":103,"correct":22},"六层市公安厅办公楼",{"key":31,"text":105,"correct":22},"座位数 1800 个的体育馆",{"id":107,"libraryId":5,"type":108,"typeLabel":109,"stem":110,"options":111,"answer":123,"analysis":33},933662,2,"多选题","消防电源指在火灾时能保证消防用电设备继续正常运行的独立电源。下列属于消防电源的基本要求的有（ ）。",[112,114,116,118,120],{"key":20,"text":113,"correct":26},"可靠性",{"key":24,"text":115,"correct":26},"耐火性",{"key":28,"text":117,"correct":22},"节能性",{"key":31,"text":119,"correct":26},"安全性",{"key":121,"text":122,"correct":26},"E","有效性","ABDE",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":31,"analysis":33},933663,"下列关于消防水泵的选择和应用的说法，错误的是（ ）。",[128,130,132,134],{"key":20,"text":129,"correct":22},"泵轴的密封方式和材料应满足消防水泵在低流量时运转的要求",{"key":24,"text":131,"correct":22},"多台消防水泵并联时，应校核流量叠加时对消防水泵出口压力的影响",{"key":28,"text":133,"correct":22},"消防水泵的性能应满足消防给水系统所需流量和压力的要求",{"key":31,"text":135,"correct":26},"消防给水同一泵组的消防水泵型号宜一致，且工作泵不宜超过5台",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":28,"analysis":33},933664,"下列关于柴油机消防水泵的说法，正确的是（ ）。",[140,142,144,146],{"key":20,"text":141,"correct":22},"柴油机消防水泵应具备连续工作性能，试验运行时间不应小于12h",{"key":24,"text":143,"correct":22},"柴油机消防水泵应采用火花塞式点火型柴油机",{"key":28,"text":145,"correct":26},"柴油机消防水泵的蓄电池应满足消防水泵随时自动启泵的要求",{"key":31,"text":147,"correct":22},"柴油机消防泵的额定功率不受外界环境和海拔影响",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":20,"analysis":33},933665,"下列关于消防水泵的串联和并联的说法，正确的是（ ）。",[152,154,156,158],{"key":20,"text":153,"correct":26},"消防水泵的串联是将一台泵的出水口与另一台泵的吸水管连接",{"key":24,"text":155,"correct":22},"消防水泵的串联在扬程不变的情况下可以增加流量",{"key":28,"text":157,"correct":22},"消防水泵的并联在流量不变的情况下可以增加扬程",{"key":31,"text":159,"correct":22},"消防水泵的并联是将一台泵的出水口与另一台泵的吸水管连接",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":28,"analysis":33},933666,"下列关于消防水泵管路布置的说法中，错误的是（ ）。",[164,166,168,170],{"key":20,"text":165,"correct":22},"消防水泵出水管路应能承受一定的压力，保证不漏水",{"key":24,"text":167,"correct":22},"消防水泵吸水管应保证不漏气",{"key":28,"text":169,"correct":26},"消防水泵出水管的直径大于DN250时，其流速宜为1．5～2．0m／s",{"key":31,"text":171,"correct":22},"消防水泵吸水管的直径小于DN250时，其流速宜为1．0～1．2m／s",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":24,"analysis":33},933667,"某建筑设有两组消防水泵，并在水泵房设有流量和压力测试装置，每台消防水泵出水管上均设有试水管，试水管管径应为（ ）。",[176,178,180,182],{"key":20,"text":177,"correct":22},"DN32",{"key":24,"text":179,"correct":26},"DN65",{"key":28,"text":181,"correct":22},"DN100",{"key":31,"text":183,"correct":22},"DN150",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":24,"analysis":33},933668,"消防水泵在正常工作状态下，从接到启泵信号到正常运转的自动启动时间不应大于（ ）s。",[188,190,192,194],{"key":20,"text":189,"correct":22},"60",{"key":24,"text":191,"correct":26},"120",{"key":28,"text":193,"correct":22},"150",{"key":31,"text":195,"correct":22},"200",{"id":197,"libraryId":5,"type":15,"typeLabel":16,"stem":198,"options":199,"answer":31,"analysis":33},933669,"下列关于消防水泵控制柜的说法，正确的是（ ）。",[200,202,204,206],{"key":20,"text":201,"correct":22},"消防水泵控制柜应具备自动巡检可调、显示巡检状态和信号等功能，对话界面应有英汉双语介绍，图标应便于识别和操作",{"key":24,"text":203,"correct":22},"消防水泵控制柜平时应使消防水泵处于手动启泵状态",{"key":28,"text":205,"correct":22},"消防水泵控制柜与消防水泵设置在同一空间时，防护等级不应低于IP56",{"key":31,"text":207,"correct":26},"消防水泵控制柜设置在专用消防水泵控制室时，防护等级不应低于IP30",{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":28,"analysis":33},933670,"下列关于消防给水应采用环状给水管网的说法，不正确的是（ ）。",[212,214,216,218],{"key":20,"text":213,"correct":22},"向两栋或两座及以上建筑供水时",{"key":24,"text":215,"correct":22},"向两种及以上水灭火系统供水时",{"key":28,"text":217,"correct":26},"采用低压消防给水系统时",{"key":31,"text":219,"correct":22},"向两个及以上报警阀控制的自动水灭火系统供水时",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":20,"analysis":33},933671,"下列关于室外消防给水管网的说法，正确的是（ ）。",[224,226,228,230],{"key":20,"text":225,"correct":26},"室外消防给水采用两路消防供水时应布置成环状管网，但当采用一路消防供水时可布置成枝状",{"key":24,"text":227,"correct":22},"管道的直径应根据流量、流速和压力要求经计算确定，但不应小于DN65",{"key":28,"text":229,"correct":22},"向环状管网输水的进水管不应少于两条，当其中一条发生故障时，剩余输水干管仅满足生活用水量即可",{"key":31,"text":231,"correct":22},"给水管道应采用阀门分成若干独立段，每段室外消火栓的数量不宜超过6个",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":24,"analysis":33},933672,"下列有关室内消防给水管道的说法，错误的是（ ）。",[236,238,240,242],{"key":20,"text":237,"correct":22},"室内消火栓竖管直径应根据竖管最低流量经计算确定，但不应小于DN100",{"key":24,"text":239,"correct":26},"室内消火栓系统与自动喷水灭火系统合用消防泵时，供水管路应沿水流方向在报警阀后分开设置",{"key":28,"text":241,"correct":22},"室内消防给水管道每根竖管与供水横干管相接处应设置阀门",{"key":31,"text":243,"correct":22},"室内消火栓竖管应保证检修管道时关闭停用的竖管不超过1根，当竖管超过4根时，可关闭不相邻的2根",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":28,"analysis":33},933673,"墙壁消防水泵接合器的安装高度距地面宜为（ ）m，与墙面上的门、窗、孔、洞的净距离不应小于（ ）m。",[248,250,252,254],{"key":20,"text":249,"correct":22},"0．70，4．0",{"key":24,"text":251,"correct":22},"1．10，2．0",{"key":28,"text":253,"correct":26},"0．70．2．0",{"key":31,"text":255,"correct":22},"1．10．4．0",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":28,"analysis":33},933674,"某建筑室内消火栓系统设计流量为45L／s，根据消防水泵接合器流量计算，该建筑的消防水泵接合器数量不应少于（ ）个。",[260,262,264,266],{"key":20,"text":261,"correct":22},"1",{"key":24,"text":263,"correct":22},"2",{"key":28,"text":265,"correct":26},"3",{"key":31,"text":267,"correct":22},"4",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":28,"analysis":33},933675,"某采用临时高压给消防水系统的建筑设有稳压泵和气压水罐，在对气压水罐调节容积进行计算时，应根据稳压泵启泵次数不大于（ ）次／h计算。",[272,274,276,278],{"key":20,"text":273,"correct":22},"5",{"key":24,"text":275,"correct":22},"10",{"key":28,"text":277,"correct":26},"15",{"key":31,"text":279,"correct":22},"20",{"id":281,"libraryId":5,"type":15,"typeLabel":16,"stem":282,"options":283,"answer":28,"analysis":33},933676,"稳压泵的设计压力应保持系统最不利点处水灭火设施在准工作状态时的静水压力应大于（ ）MPa。",[284,286,288,290],{"key":20,"text":285,"correct":22},"0．07",{"key":24,"text":287,"correct":22},"0．10",{"key":28,"text":289,"correct":26},"0．15",{"key":31,"text":291,"correct":22},"0．25",{"id":293,"libraryId":5,"type":15,"typeLabel":16,"stem":294,"options":295,"answer":31,"analysis":33},933677,"根据《消防给水及消火栓系统技术规范》（GB50974--2014）的规定要求，下列关于消防水池取水井与采取辐射热保护措施的液化石油气储罐区之间距离符合规定的是（ ）m。",[296,297,299,301],{"key":20,"text":279,"correct":22},{"key":24,"text":298,"correct":22},"30",{"key":28,"text":300,"correct":22},"35",{"key":31,"text":302,"correct":26},"40",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":28,"analysis":33},933678,"下列关于消防给水系统采用减压阀减压分区供水的说法，不正确的是（ ）。",[307,309,311,313],{"key":20,"text":308,"correct":22},"每一供水分区应设不少于两组减压阀组，每组减压阀组宜设置备用减压阀",{"key":24,"text":310,"correct":22},"减压阀宜采用比例式减压阀，当超过1．20MPa时，宜采用先导式减压阀",{"key":28,"text":312,"correct":26},"当采用两级减压阀串联减压时，第二级减压阀宜采用比例式减压阀",{"key":31,"text":314,"correct":22},"减压阀仅应设置在单向流动的供水管上，不应设置在有双向流动的输水干管上",{"id":316,"libraryId":5,"type":15,"typeLabel":16,"stem":317,"options":318,"answer":28,"analysis":33},933679,"某采用高压消防给水系统的高层民用建筑在顶部设有高位消防水池，火灾时补水可靠，该建筑室内消防用水总量为450m3，则该高位消防水池最小有效容积不应小于（ ）m3。",[319,320,322,324],{"key":20,"text":191,"correct":22},{"key":24,"text":321,"correct":22},"198",{"key":28,"text":323,"correct":26},"225",{"key":31,"text":325,"correct":22},"328",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":31,"analysis":33},933680,"轴流深井泵安装于水井时，其淹没深度应满足其可靠运行的要求，在水泵出流量为150％设计流量时，其最低淹没深度应是第一个水泵叶轮底部水位线以上不少于（ ）m。",[330,331,333,334],{"key":20,"text":263,"correct":22},{"key":24,"text":332,"correct":22},"2．5",{"key":28,"text":265,"correct":22},{"key":31,"text":335,"correct":26},"3．2",{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":28,"analysis":33},933681,"当市政给水管网设有市政消火栓时，其平时运行工作压力不应小于（ ）MPa。",[340,341,343,345],{"key":20,"text":287,"correct":22},{"key":24,"text":342,"correct":22},"0．12",{"key":28,"text":344,"correct":26},"0．14",{"key":31,"text":289,"correct":22},{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":31,"analysis":33},933682,"下列关于市政消火栓设置要求的说法，正确的是（ ）。",[350,352,354,356],{"key":20,"text":351,"correct":22},"市政消火栓距路边不应大于5．0m",{"key":24,"text":353,"correct":22},"市政消火栓距路边不宜小于0．2m处",{"key":28,"text":355,"correct":22},"市政消火栓距建筑外墙或外墙边缘不宜小于2．0m",{"key":31,"text":357,"correct":26},"市政桥桥头和城市交通隧道出入口等市政公用设施处，应设置市政消火栓",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":31,"analysis":33},933683,"稳压泵设有三个压力控制点，分别为p1、p2、p3，其中p1为稳压上限，p2为稳压下限，p3为消防主泵启动压力点。下列关于这三个压力控制点的说法，正确的是（ ）。",[362,364,366,368],{"key":20,"text":363,"correct":22},"当压力达到p2时，稳压泵停止",{"key":24,"text":365,"correct":22},"当压力达到p1时，稳压泵启动",{"key":28,"text":367,"correct":22},"当压力达到p3时，稳压泵启动，消防主泵也同时启动",{"key":31,"text":369,"correct":26},"以上说法都不对",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":28,"analysis":33},933684,"某办公楼建筑高度为48m，其消防扑救面一侧的室外消火栓的数量不宜少于（ ）个。",[374,375,376,377],{"key":20,"text":273,"correct":22},{"key":24,"text":265,"correct":22},{"key":28,"text":263,"correct":26},{"key":31,"text":267,"correct":22},{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":31,"analysis":33},933685,"室内消火栓设计流量的确定与下列因素无关的是（ ）。",[382,384,386,388],{"key":20,"text":383,"correct":22},"建筑耐火等级",{"key":24,"text":385,"correct":22},"建筑体积",{"key":28,"text":387,"correct":22},"建筑功能性质",{"key":31,"text":389,"correct":26},"建筑防火间距",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":20,"analysis":33},933686,"某采用临时高压消防给水系统的工艺装置区周围设有室外消火栓，根据《消防给水及消火栓系统技术规范》（GB50974—2014）的规定，其间距不应大于（ ）m。",[394,395,397,398],{"key":20,"text":189,"correct":26},{"key":24,"text":396,"correct":22},"80",{"key":28,"text":191,"correct":22},{"key":31,"text":193,"correct":22},{"id":400,"libraryId":5,"type":15,"typeLabel":16,"stem":401,"options":402,"answer":24,"analysis":33},933687,"某建筑高度为62m的办公楼，地上12层，采用临时高压消防给水形式，设有室内外消火栓系统，当系统工作压力为3．2MPa时，应采用（ ）方式减压。",[403,405,407,409],{"key":20,"text":404,"correct":22},"减压阀",{"key":24,"text":406,"correct":26},"消防水泵串联",{"key":28,"text":408,"correct":22},"节流管",{"key":31,"text":410,"correct":22},"减压孔板",{"id":412,"libraryId":5,"type":15,"typeLabel":16,"stem":413,"options":414,"answer":24,"analysis":33},933688,"根据《消防给水及消火栓系统技术规范》（GB50974—2014）的规定，自动喷水灭火系统报警阀处的工作压力大于（ ）MPa或喷头处的工作压力大于（ ）MPa时，消防给水系统应分区供水。",[415,417,419,421],{"key":20,"text":416,"correct":22},"1．2，1．0",{"key":24,"text":418,"correct":26},"1．6，1．2",{"key":28,"text":420,"correct":22},"2．4，1．2",{"key":31,"text":422,"correct":22},"2．4，1．0",{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":24,"analysis":33},933689,"某住宅，建筑高度为120m，设有高位消防水箱，则该建筑室内消火栓系统最不利点处静水压力不应低于（ ）MPa。",[427,429,430,431],{"key":20,"text":428,"correct":22},"0．05",{"key":24,"text":285,"correct":26},{"key":28,"text":287,"correct":22},{"key":31,"text":289,"correct":22},{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":31,"analysis":33},933690,"室内消火栓栓口静压大于（ ）MPa时应采取分区供水。",[436,438,440,442],{"key":20,"text":437,"correct":22},"0．35",{"key":24,"text":439,"correct":22},"0．5",{"key":28,"text":441,"correct":22},"0．7",{"key":31,"text":443,"correct":26},"1．0",{"id":445,"libraryId":5,"type":15,"typeLabel":16,"stem":446,"options":447,"answer":28,"analysis":33},933691,"下列关于减压水箱设置的说法，错误的是（ ）。",[448,450,452,454],{"key":20,"text":449,"correct":22},"减压水箱与其他生活用水共用时应采取确保消防用水量不作他用的技术措施",{"key":24,"text":451,"correct":22},"减压水箱应设置溢流水管和排水设施，并应采用间接排水",{"key":28,"text":453,"correct":26},"减压水箱的有效容积不应小于18m3，且宜分为两座",{"key":31,"text":455,"correct":22},"减压水箱应设置就地水位显示装置",{"id":457,"libraryId":5,"type":15,"typeLabel":16,"stem":458,"options":459,"answer":28,"analysis":33},933692,"下列有关消防水泵吸水管和出水管上设置压力表的说法，不正确的是（ ）。",[460,462,464,466],{"key":20,"text":461,"correct":22},"压力表应采用直径不小于6mm的管道与消防水泵进出口管相接",{"key":24,"text":463,"correct":22},"压力表的直径不应小于100mm",{"key":28,"text":465,"correct":26},"消防水泵出水管压力表的最大量程不应低于设计工作压力的3倍，且不应低于1．6MPa",{"key":31,"text":467,"correct":22},"消防水泵吸水管上压力表的最大量程不应低于0．7MPa",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":31,"analysis":33},933693,"当室外消防给水系统因引入管设有倒流防止器，在火灾时因其水头损失导致室外消火栓的出流量和压力不能满足相应的要求时，应采取的有效措施是（ ）。",[472,474,476,478],{"key":20,"text":473,"correct":22},"增加供水时间",{"key":24,"text":475,"correct":22},"采用高压消防给水系统",{"key":28,"text":477,"correct":22},"在倒流防止器后增加室外消火栓",{"key":31,"text":479,"correct":26},"在倒流防止器前增加室外消火栓",{"id":481,"libraryId":5,"type":15,"typeLabel":16,"stem":482,"options":483,"answer":20,"analysis":33},933694,"某民用建筑，一至二层为商场，每层建筑面积为5000m2，三至十四层为住宅，每层建筑面积为1500m2，建筑首层室内地坪标高为±0．000m，室外地坪高为-0．600m，商场平屋面面层标高为10．6m，住宅平屋面面层标高为49．8m，女儿墙顶部标高为50．9m。下列关于该建筑的说法，不符合规定的是（ ）。",[484,486,488,490],{"key":20,"text":485,"correct":26},"建筑消防救援场地最小尺寸不应小于15m×10m",{"key":24,"text":487,"correct":22},"该建筑室外消火栓设计流量应按公共建筑确定，并按照建筑总高度确定",{"key":28,"text":489,"correct":22},"住宅建筑的安全疏散楼梯可根据住宅部分建筑高度确定",{"key":31,"text":491,"correct":22},"商场室内消火栓系统的设置根据商场部分的高度确定",{"id":493,"libraryId":5,"type":15,"typeLabel":16,"stem":494,"options":495,"answer":28,"analysis":33},933695,"某民用建筑，地上15层，首层为小型营业性用房，每个分隔单元面积240m2，层高4m，二层及以上为住宅，层高3m，每层建筑面积1200m2，采用临时高压消防给水系统，设有室内消火栓系统、自动喷水灭火系统保护，其高位消防水箱的有效容积不应小于（ ）m3。",[496,498,500,502],{"key":20,"text":497,"correct":22},"36",{"key":24,"text":499,"correct":22},"18",{"key":28,"text":501,"correct":26},"12",{"key":31,"text":503,"correct":22},"50",{"id":505,"libraryId":5,"type":15,"typeLabel":16,"stem":506,"options":507,"answer":24,"analysis":33},933696,"下列关于消防给水系统分区供水的说法，正确的是（ ）。",[508,510,512,514],{"key":20,"text":509,"correct":22},"当采用消防水泵转输水箱串联分区供水时，转输泵应先启动，消防水泵后启动",{"key":24,"text":511,"correct":26},"当采用消防水泵直接串联分区供水时，下区消防水泵应先启动，上区消防水泵后启动",{"key":28,"text":513,"correct":22},"当采用减压阀减压分区供水时，减压阀的阀前阀后压力比值不宜大于2：1",{"key":31,"text":515,"correct":22},"当采用减压水箱分区供水时，减压水箱的有效容积不应小于60m3",{"id":517,"libraryId":5,"type":15,"typeLabel":16,"stem":518,"options":519,"answer":20,"analysis":33},933697,"耐火等级不低于二级，且建筑物体积小于等于3000m3的戊类厂房或居住区人数不超过500人且建筑物层数不超过（ ）的居住区，可不设置室外消防给水。",[520,522,524,526],{"key":20,"text":521,"correct":26},"两层",{"key":24,"text":523,"correct":22},"三层",{"key":28,"text":525,"correct":22},"四层",{"key":31,"text":527,"correct":22},"五层",{"id":529,"libraryId":5,"type":15,"typeLabel":16,"stem":530,"options":531,"answer":31,"analysis":33},933698,"市政消火栓应沿道路一侧设置，当道路宽度大于（ ）m时，宜在道路两边交叉错落设置消火栓，并宜靠近十字路口。",[532,533,534,536],{"key":20,"text":302,"correct":22},{"key":24,"text":503,"correct":22},{"key":28,"text":535,"correct":22},"55",{"key":31,"text":189,"correct":26},{"id":538,"libraryId":5,"type":15,"typeLabel":16,"stem":539,"options":540,"answer":31,"analysis":33},933699,"水泵接合器的形式不包括（ ）。",[541,543,545,547],{"key":20,"text":542,"correct":22},"地上式",{"key":24,"text":544,"correct":22},"地下式",{"key":28,"text":546,"correct":22},"墙壁式",{"key":31,"text":548,"correct":26},"顶棚式",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":28,"analysis":33},933700,"甲、乙、丙类液体储罐区和液化石油气储罐区的消火栓应设置在防火堤或防护墙外，距罐壁（ ）m范围内的消火栓，不应计算在该罐可使用的数量内。",[553,555,556,557],{"key":20,"text":554,"correct":22},"8",{"key":24,"text":275,"correct":22},{"key":28,"text":277,"correct":26},{"key":31,"text":499,"correct":22},{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":28,"analysis":33},933701,"高层建筑、厂房、库房和室内净空高度超过8m的民用建筑等场所，其消火栓栓口动压不应小于0．35MPa，且消防水枪充实水柱应达到（ ）m。",[562,563,564,566],{"key":20,"text":554,"correct":22},{"key":24,"text":501,"correct":22},{"key":28,"text":565,"correct":26},"13",{"key":31,"text":567,"correct":22},"16",{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":28,"analysis":33},933702,"下列关于可以不设置备用消防水泵的说法中，错误的是（ ）。",[572,574,576,578],{"key":20,"text":573,"correct":22},"建筑高度为40米的住宅",{"key":24,"text":575,"correct":22},"室内消防给水设计流量为10L／s的宿舍楼",{"key":28,"text":577,"correct":26},"室外消防给水设计流量为30L／s的玻璃厂房",{"key":31,"text":579,"correct":22},"室内消防给水设计流量为10L／s的甲醇生产厂房",{"id":581,"libraryId":5,"type":15,"typeLabel":16,"stem":582,"options":583,"answer":24,"analysis":33},933703,"下列关于设置的高位消防水箱有效容积的说法中，不符合规范要求的是（ ）。",[584,586,588,590],{"key":20,"text":585,"correct":22},"建筑高度为30m的医院，40m3",{"key":24,"text":587,"correct":26},"建筑高度为30m住宅，10m3",{"key":28,"text":589,"correct":22},"建筑高度为18m地上四层商场，20m3",{"key":31,"text":591,"correct":22},"建筑高度为22m的多层住宅，10m3",{"id":593,"libraryId":5,"type":15,"typeLabel":16,"stem":594,"options":595,"answer":24,"analysis":33},933704,"除某些情况外，当室外消火栓设计流量不大于（），且室内消火栓数量不超过（）个时，室内消火栓系统管网可布置成枝状。",[596,598,600,602],{"key":20,"text":597,"correct":22},"25L／s，10",{"key":24,"text":599,"correct":26},"20L／s．10",{"key":28,"text":601,"correct":22},"15L／s，5",{"key":31,"text":603,"correct":22},"10L／s，5",[605,608,611,614,617,620],{"id":15,"name":606,"category":7,"favorite":607},"领导干部任职前廉政法规知识测试题",92,{"id":609,"name":610,"category":7,"favorite":15},595,"建筑结构与设备",{"id":612,"name":613,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":615,"name":616,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":618,"name":619,"category":7,"favorite":8},534,"BIM工程师",{"id":621,"name":619,"category":7,"favorite":8},535]