[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-4":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":628},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,4,50,2960,[13,34,46,58,70,82,100,112,121,133,145,157,169,181,193,205,217,229,241,253,265,277,289,301,313,325,337,349,361,373,385,397,409,424,436,448,460,472,484,496,508,520,535,550,559,570,582,594,608,620],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},931831,1,"单选题","（2017真题）某总建筑面积为900㎡的办公建筑，地上3层，地下1层，地上部分为办公用房，地下一层为自行车库和设备用房，该建筑地下部分最低耐火等级为（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","二级",false,{"key":24,"text":25,"correct":26},"B","一级",true,{"key":28,"text":29,"correct":22},"C","三级",{"key":31,"text":32,"correct":22},"D","四级","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},931832,"（2017真题）采用非吸气型喷射装置的泡沫喷淋保护非水溶性甲，乙，丙类液体时，应选用（ ）",[38,40,42,44],{"key":20,"text":39,"correct":26},"水成膜泡沫液或成膜氟蛋白泡沫液",{"key":24,"text":41,"correct":22},"蛋白泡沫液",{"key":28,"text":43,"correct":22},"氟蛋白泡沫液",{"key":31,"text":45,"correct":22},"抗溶性泡沫液",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},931833,"（2017真题）闭式泡沫—水喷淋系统的供给强度不应小于（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"4.5",{"key":24,"text":53,"correct":26},"6.5",{"key":28,"text":55,"correct":22},"5.0",{"key":31,"text":57,"correct":22},"6.0",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":20,"analysis":33},931835,"（2019年真题）关于泡沫灭火系统的说法，错误的是（）",[62,64,66,68],{"key":20,"text":63,"correct":26},"半固定系统是移动式泡沫产生器，固定的泡沫消防水泵或泡沫混合液泵，泡沫比例混合器（装置），用管线或水带连接组成的灭火系统",{"key":24,"text":65,"correct":22},"泡沫混合液泵是为采用环泵式比例混合器的泡沫灭火系统供给泡沫混合液的水泵",{"key":28,"text":67,"correct":22},"泡沫消防水泵是为采用压力式等比例混合装置的泡沫灭火系统供水的水泵",{"key":31,"text":69,"correct":22},"当采用压力式比例混合装置时，泡沫液储罐的单罐容积不应大于10m3",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},931836,"（2019年真题）某单罐容积为60000m3的轻柴油内浮顶储罐，设置低倍数泡沫灭灭系统时，应选用（）?",[74,76,78,80],{"key":20,"text":75,"correct":22},"半固定式液上喷射系统",{"key":24,"text":77,"correct":22},"固定式半液下喷射系统",{"key":28,"text":79,"correct":22},"固定式液下喷射系统",{"key":31,"text":81,"correct":26},"固定式液上喷射系统",{"id":83,"libraryId":5,"type":84,"typeLabel":85,"stem":86,"options":87,"answer":99,"analysis":33},931837,2,"多选题","（2019年真题）某储罐区共有7个直径32m的非水溶性丙类液体固定顶储罐，均设置固定式液上喷射低倍数泡沫灭火系统。关于该灭火系统设计的说法，正确的有（）",[88,90,92,94,96],{"key":20,"text":89,"correct":26},"泡沫灭火系统应具备半固定式系统功能",{"key":24,"text":91,"correct":22},"每个储罐的泡沫产生器不应少于3个",{"key":28,"text":93,"correct":22},"泡沫混合液供给强度不应小于4L\u002F（min?㎡）",{"key":31,"text":95,"correct":26},"泡沫混合液泵启动后，将泡沫混合液输送到保护对象的时间不应不大于5min",{"key":97,"text":98,"correct":26},"E","泡沫混合液连续供给时间不应小于30min","ADE",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":24,"analysis":33},931838,"（2020年真题）按系统形式划分，泡沫灭火系统不包括（ ）。",[104,106,108,110],{"key":20,"text":105,"correct":22},"全淹没系统",{"key":24,"text":107,"correct":26},"半固定式系统",{"key":28,"text":109,"correct":22},"局部应用系统",{"key":31,"text":111,"correct":22},"移动系统",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":28,"analysis":33},931839,"（2020年真题）某容积为2000m3的乙醇固定顶储罐设置低倍数泡沫灭火系统时，应选用（ ）。",[116,117,119,120],{"key":20,"text":75,"correct":22},{"key":24,"text":118,"correct":22},"半固定式半液下喷射系统",{"key":28,"text":81,"correct":26},{"key":31,"text":79,"correct":22},{"id":122,"libraryId":5,"type":15,"typeLabel":16,"stem":123,"options":124,"answer":28,"analysis":33},931840,"（2015真题）下列关于干粉灭火系统组件及其设置要求的说法中，正确的是（）。",[125,127,129,131],{"key":20,"text":126,"correct":22},"储存装置的驱动气体应选用压缩空气",{"key":24,"text":128,"correct":22},"储存装置可设在耐火等级为三级的房间内",{"key":28,"text":130,"correct":26},"干粉储存容器设计压力可取1.6MPa或2.5MPa压力级",{"key":31,"text":132,"correct":22},"驱动压力应大于储存容器的最高工作压力",{"id":134,"libraryId":5,"type":15,"typeLabel":16,"stem":135,"options":136,"answer":31,"analysis":33},931841,"（2016真题）某大型钢铁企业设置了预制干粉灭火装置。下列关于该装置设置要求的说法中正确的是（）。",[137,139,141,143],{"key":20,"text":138,"correct":22},"一个防护区或保护对象所用预制干粉灭火装置最多不得超过4套，并应同时启动，其动作响应时间差不得大于4s",{"key":24,"text":140,"correct":22},"一个防护区或保护对象所用预制干粉灭火装置最多不得超过8套，并应同时启动，其动作响应时间差不得大于2s",{"key":28,"text":142,"correct":22},"一个防护区或保护对象所用预制干粉灭火装置最多不得超过8套，并应同时启动，其动作响应时间差不得大于4s",{"key":31,"text":144,"correct":26},"一个防护区或保护对象所用预制干粉灭火装置最多不得超过4套，并应同时启动，其动作响应时间差不得大于2s",{"id":146,"libraryId":5,"type":15,"typeLabel":16,"stem":147,"options":148,"answer":28,"analysis":33},931842,"（2018真题）磷酸铵盐干粉灭火剂不适合扑救（ ）火灾。",[149,151,153,155],{"key":20,"text":150,"correct":22},"汽油",{"key":24,"text":152,"correct":22},"石蜡",{"key":28,"text":154,"correct":26},"钠",{"key":31,"text":156,"correct":22},"木制家具",{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":31,"analysis":33},931843,"（2016真题）下列灭火器中，灭火剂的灭火机理为化学抑制作用的是（ ）",[161,163,165,167],{"key":20,"text":162,"correct":22},"泡沫灭火器",{"key":24,"text":164,"correct":22},"二氧化碳灭火器",{"key":28,"text":166,"correct":22},"水基型灭火器",{"key":31,"text":168,"correct":26},"干粉灭火器",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":20,"analysis":33},931844,"（2019年真题）关于干粉灭火系统的说法，正确的是（）",[173,175,177,179],{"key":20,"text":174,"correct":26},"管道分支不应使用四通管件心",{"key":24,"text":176,"correct":22},"干粉储存器设计压力可取2.5Mpa或4.2MPa压力级",{"key":28,"text":178,"correct":22},"官网中阀门之间的封闭管段不应设置任何开口和装置",{"key":31,"text":180,"correct":22},"干粉储存容器的装量系数不应大于0.75",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":31,"analysis":33},931846,"（2018真题）某文物库采用细水雾灭火系统进行保护，系统选型为全淹没应用方式的开式系统。该系统最不利点工作压力为（）。",[185,187,189,191],{"key":20,"text":186,"correct":22},"0.1MPa",{"key":24,"text":188,"correct":22},"1.0MPa",{"key":28,"text":190,"correct":22},"1.6MPa",{"key":31,"text":192,"correct":26},"1.2MPa",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":31,"analysis":33},931847,"（2016真题）下列关于细水喷雾灭火系统联动控制的做法中，错误的是（ ）。",[197,199,201,203],{"key":20,"text":198,"correct":22},"开式系统在接收到两个不同类型的火灾报警信号后自动启动",{"key":24,"text":200,"correct":22},"开式系统在接收到两个独立回路中相同类型的两个火灾报警信号后自动启动",{"key":28,"text":202,"correct":22},"闭式系统在喷头动作后，由压力开关直接连锁自动启动",{"key":31,"text":204,"correct":26},"闭式系统在喷头动作后，由分区控制阀启闭信号自动启动",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":24,"analysis":33},931848,"（2017真题）细水雾灭火系统按供水方式分类,可分为泵组式系统、瓶组与泵组结合式系统和()",[209,211,213,215],{"key":20,"text":210,"correct":22},"低压系统",{"key":24,"text":212,"correct":26},"瓶组式系统",{"key":28,"text":214,"correct":22},"中压系统",{"key":31,"text":216,"correct":22},"高压系统",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":31,"analysis":33},931849,"（2015真题）基于细水雾灭火系统的灭火原理，下列场所中，细水雾灭火系统不适用于扑救的是（）。",[221,223,225,227],{"key":20,"text":222,"correct":22},"电缆夹层",{"key":24,"text":224,"correct":22},"柴油发电机",{"key":28,"text":226,"correct":22},"锅炉房",{"key":31,"text":228,"correct":26},"电石仓库",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":24,"analysis":33},931850,"（2019年真题）某燃油锅炉房拟采用细水雾灭火系统。为确定设计参数，进行了实体火灾模拟实验，实验结果为：喷头安装高度为4.5m，布置间距为2.8m，喷雾强度为0.8L\u002F(min*㎡)，最不利点喷头的工作压力为9MPa。下列根据模拟实验结果确定的设计方案中，正确的是（）",[233,235,237,239],{"key":20,"text":234,"correct":22},"喷头设计安装高度为5m",{"key":24,"text":236,"correct":26},"设计喷雾强度为1.0L\u002F（min*㎡）",{"key":28,"text":238,"correct":22},"喷头设计布置间距为3m",{"key":31,"text":240,"correct":22},"喷头设计最低工作压力为8MPa",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":20,"analysis":33},931851,"（2020年真题）某档案库，地上6层，地下1层。三层的珍藏库采用非密集柜方式存储档案资料，该珍藏库设置的闭式细水雾灭火系统可选择喷头的响应时间指数（RTI）最大为（ ）（m.S）0.5",[245,247,249,251],{"key":20,"text":246,"correct":26},"50",{"key":24,"text":248,"correct":22},"40",{"key":28,"text":250,"correct":22},"60",{"key":31,"text":252,"correct":22},"70",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":20,"analysis":33},931852,"（2017真题）某酒店厨房的火灾探测器经常误报火警，最可能的原因是（ ）。",[257,259,261,263],{"key":20,"text":258,"correct":26},"厨房内安装的是感烟火灾探测器",{"key":24,"text":260,"correct":22},"厨房内的火灾探测器编码地址错误",{"key":28,"text":262,"correct":22},"火灾报警控制器供电电压不足",{"key":31,"text":264,"correct":22},"厨房内的火灾探测器通信信号总线故障",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":28,"analysis":33},931853,"（2017真题）关于火灾探测器的说法，正确的是（ ）。",[269,271,273,275],{"key":20,"text":270,"correct":22},"点型感温探测器是不可复位探测器",{"key":24,"text":272,"correct":22},"感烟型火灾探测器都是点型火灾探测器",{"key":28,"text":274,"correct":26},"既能探测烟雾又能探测温度的探测器是复合火灾探测器",{"key":31,"text":276,"correct":22},"剩余电流式电气火灾监控探测器不属于火灾探测器",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":24,"analysis":33},931854,"（2017真题）关于火灾自动报警系统组件的说法，正确的是（ ）。",[281,283,285,287],{"key":20,"text":282,"correct":22},"手动火灾报警按钮是手动产生火灾报警信号的器件，不属于火灾自动报警系统触发器件",{"key":24,"text":284,"correct":26},"火灾报警控制器可以接收、显示和传递火灾报警信号，并能发出控制信号",{"key":28,"text":286,"correct":22},"剩余电流式电气火灾监控探测器与电气火灾监控器连接，不属于火灾自动报警系统",{"key":31,"text":288,"correct":22},"火灾自动报警系统备用电源采用的蓄电池满足供电时间要求时，主电源可不采用消防电源",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":31,"analysis":33},931855,"（2017真题）关于控制中心报警系统的说法，不符合规范要求的是（ ）。",[293,295,297,299],{"key":20,"text":294,"correct":22},"控制中心报警系统至少包含两个集中报警系统",{"key":24,"text":296,"correct":22},"控制中心报警系统具备消防联动控制功能",{"key":28,"text":298,"correct":22},"控制中心报警系统至少设置一个消防主控制室",{"key":31,"text":300,"correct":26},"控制中心报警系统各分消防控制室之间可以相互传输信息并控制重要设备",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":28,"analysis":33},931856,"（2017真题）下列场所中，不宜选择感烟探测器的是（ ）。",[305,307,309,311],{"key":20,"text":306,"correct":22},"汽车库",{"key":24,"text":308,"correct":22},"计算机房",{"key":28,"text":310,"correct":26},"发电机房",{"key":31,"text":312,"correct":22},"电梯机房",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":24,"analysis":33},931857,"（2017真题）根据防排烟系统的联动控制设计要求，当（ ）时，送风口不会动作。",[317,319,321,323],{"key":20,"text":318,"correct":22},"同一防护区内一只火灾探测器和一只手动报警按钮报警",{"key":24,"text":320,"correct":26},"联动控制器接收到送风机启动的反馈信号",{"key":28,"text":322,"correct":22},"同一防护区内两只独立的感烟探测器报警",{"key":31,"text":324,"correct":22},"在联动控制器上手动控制送风口开启",{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":31,"analysis":33},931859,"（2015真题）某设置有中央空调送风系统的建筑，其火灾自动报警系统中的点型火灾探测器至空调送风口和多孔送风顶棚孔口边缘的水平距离，分别不应小于（ ）m。",[329,331,333,335],{"key":20,"text":330,"correct":22},"1.2，1.0",{"key":24,"text":332,"correct":22},"2.0，1.0",{"key":28,"text":334,"correct":22},"1.0，1.5",{"key":31,"text":336,"correct":26},"1.5，0.5",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":31,"analysis":33},931860,"（2016真题）某藏书60万册的图书馆，其条形疏散走道宽度为2.1m，长度为51m，该走道顶棚上至少应设置（ ）只点型感烟火灾探测器。",[341,343,345,347],{"key":20,"text":342,"correct":22},"2",{"key":24,"text":344,"correct":22},"3",{"key":28,"text":346,"correct":22},"5",{"key":31,"text":348,"correct":26},"4",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":24,"analysis":33},931861,"（2016真题）下列关于火灾自动报警系统组件设置的做法中，错误的是（ ）。",[353,355,357,359],{"key":20,"text":354,"correct":22},"壁挂手动火灾报警按钮的底边距离楼地面1.4m",{"key":24,"text":356,"correct":26},"壁挂紧急广播扬声器的底边距离楼地面2.2m",{"key":28,"text":358,"correct":22},"壁挂消防联动控制器的主显示屏的底边距离楼地面1.5m",{"key":31,"text":360,"correct":22},"墙上安装的消防专用电话插孔的底边距离楼地面1.3m",{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":28,"analysis":33},931862,"（2016真题）某建筑面积为2000m2的展厅，层高为7m，设置了格栅吊顶，吊顶距离楼地面6m，镂空面积与吊顶的总面积之比为10%。该展厅内感烟火灾探测器应设置的位置是（ ）。",[365,367,369,371],{"key":20,"text":366,"correct":22},"吊顶上方",{"key":24,"text":368,"correct":22},"吊顶上方和下方",{"key":28,"text":370,"correct":26},"吊顶下方",{"key":31,"text":372,"correct":22},"根据实际实验结果确定",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":24,"analysis":33},931863,"（2015真题）感烟火灾探测器是响应悬浮在空气中的燃烧和\u002F或热解产生的固体或液体微粒的探测器，可分为离子感烟、红外光束感烟、吸气型和（ ）等探测器。",[377,379,381,383],{"key":20,"text":378,"correct":22},"火焰探测",{"key":24,"text":380,"correct":26},"光电感烟",{"key":28,"text":382,"correct":22},"光纤感烟",{"key":31,"text":384,"correct":22},"缆式线型探测",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":28,"analysis":33},931864,"（2015真题）根据《火灾自动报警系统设计规范》GB50116-2013的规定，火灾自动报警系统的形式可分为区域报警系统、集中报警系统和（ ）。",[389,391,393,395],{"key":20,"text":390,"correct":22},"消防联动报警系统",{"key":24,"text":392,"correct":22},"火灾探测报警系统",{"key":28,"text":394,"correct":26},"控制中心报警系统",{"key":31,"text":396,"correct":22},"集中区域报警系统",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":31,"analysis":33},931865,"（2015真题）根据《火灾自动报警系统设计规范》GB50116—2013的规定，区域报警系统应由火灾探测器、手动火灾报警按钮、火灾报警控制器和（ ）等组成。",[401,403,405,407],{"key":20,"text":402,"correct":22},"消防应急广播",{"key":24,"text":404,"correct":22},"消防专用电话",{"key":28,"text":406,"correct":22},"气体灭火控制器",{"key":31,"text":408,"correct":26},"火灾声光警报器",{"id":410,"libraryId":5,"type":84,"typeLabel":85,"stem":411,"options":412,"answer":423,"analysis":33},931866,"（2016真题）某建筑高度为24m的商业建筑，中部设置一个面积为600m2，贯穿建筑地上5层的中庭，该中庭同时设置线型光束感烟火灾探测器和图像型火灾探测器，中庭的环廊设置点型感烟火灾探测器，环廊与中庭之间无防烟分隔，中庭顶部设置机械排烟设施。下列报警信号中，可作为中庭顶部机械排烟设施开启的联动触发信号有（ ）。",[413,415,417,419,421],{"key":20,"text":414,"correct":26},"中庭任一线型光束感火灾烟探测器和任一图像型火焰探测器的报警信号",{"key":24,"text":416,"correct":26},"中庭两个地址线型光束感烟火灾探测器的报警信号",{"key":28,"text":418,"correct":26},"中庭任一线型光束感烟火灾探测器与环廊任一点型感烟火灾探测器的报警信号",{"key":31,"text":420,"correct":26},"中庭两个地址图像型火焰探测器的报警信号",{"key":97,"text":422,"correct":22},"环廊任一点型感烟火灾探测器及其相邻商铺内任一火灾探测器的报警信号","ABCD",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":20,"analysis":33},931867,"（2015真题）在某商业建筑内的疏散走道上设置的防火卷帘，其联动控制程序应是（ ）。",[428,430,432,434],{"key":20,"text":429,"correct":26},"专门用于联动防火卷帘的感烟火灾探测器动作后，防火卷帘下降至距楼板面1.8m处；专门用于联动防火卷帘的感温火灾探测器动作后，防火卷帘下降到楼板面",{"key":24,"text":431,"correct":22},"专门用于联动防火卷帘的感温火灾探测器动作后，防火卷帘下降至距楼板面1.8m处，专门用于联动防火卷帘的感烟火灾探测器动作后，防火卷帘下降到楼板面",{"key":28,"text":433,"correct":22},"专门用于联动防火卷帘的感烟火灾探测器动作后，防火卷帘下降至距楼板面1.5m处，专门用于联动防火卷帘的感温火灾探测器动作后，防火卷帘下降到楼板面",{"key":31,"text":435,"correct":22},"专门用于联动防火卷帘的感温火灾探测器动作后，防火卷帘下降至距楼板面1.5m处；专门用于联动防火卷帘的感温火灾探测器动作后，防火卷帘下降到楼板面",{"id":437,"libraryId":5,"type":15,"typeLabel":16,"stem":438,"options":439,"answer":28,"analysis":33},931868,"（2018真题）根据现行国家标准《火灾自动报警系统设计规范》（GB50116），关于可燃气体探测器和可燃气体报警控制器设置的说法，正确的是（ ）2018真题",[440,442,444,446],{"key":20,"text":441,"correct":22},"可燃气体探测器少于8只时，可直接接入火灾报警控制器的探测回路",{"key":24,"text":443,"correct":22},"可燃气体报警控制器发出报警信号后，应由消防联动控制器启动防护区内的火灾声光警报器",{"key":28,"text":445,"correct":26},"人工煤气探测器可安装在保护区顶部",{"key":31,"text":447,"correct":22},"天然气探测器可安装在防护区的下部",{"id":449,"libraryId":5,"type":15,"typeLabel":16,"stem":450,"options":451,"answer":31,"analysis":33},931869,"（2018真题）根据现行国家标准《火灾自动报警系统设计规范》（GB50116），关于消防控制室设计的说法，正确的是（ ）。",[452,454,456,458],{"key":20,"text":453,"correct":22},"设有3个消防控制室时，各消防控制室可相互控制建筑内的消防设备",{"key":24,"text":455,"correct":22},"一类高层民用建筑的消防控制室不应与弱电系统中的中央控制室合用",{"key":28,"text":457,"correct":22},"消防控制室内双列布置的设备面板前的操作距离不应小于1.5m",{"key":31,"text":459,"correct":26},"消防控制室内的消防控制室图形显示装置应能显示消防安全管理信息",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":24,"analysis":33},931870,"（2018真题）某商场中庭开口部位设置用作置用作防火分隔的防火卷帘。根据现行国家标准《火灾自动报警系统设计规范》（GB50116）关于该防火卷帘联动控制的说法，正确的是（ ）。",[464,466,468,470],{"key":20,"text":465,"correct":22},"应由设置在防火卷帘所在防火分区内任一专门联动动防火卷帘的感温火灾探测器的报警信号作为联动触发信号，联动控制防火卷帘直接下降到楼板面",{"key":24,"text":467,"correct":26},"防火卷帘下降到楼板面的动作信号和直接与防火卷帘控制器连接的火灾探测器报警信号，应反馈至消防控制室内的消防联动控制器",{"key":28,"text":469,"correct":22},"应由防火卷一侧距卷帘纵深0.5m-5m内设置的感温火灾探测器报警信号作为联动触发信号，联动控制防火卷帘直接下降到楼板面",{"key":31,"text":471,"correct":22},"防火卷帘两侧设置的手动控制按钮应能控制防火卷帘的升降，在消防控制室内消防联动控制器上不得手动控制防火卷帘的降落",{"id":473,"libraryId":5,"type":15,"typeLabel":16,"stem":474,"options":475,"answer":24,"analysis":33},931871,"（2018真题）根据现行国家标准《火灾自动报警系统设计规范》，（ ）不属于区域火灾报警系统组成部分。",[476,478,480,482],{"key":20,"text":477,"correct":22},"火灾探测器",{"key":24,"text":479,"correct":26},"消防联动控制器",{"key":28,"text":481,"correct":22},"手动火灾报警按钮",{"key":31,"text":483,"correct":22},"火灾报警控制器",{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":31,"analysis":33},931872,"（2015真题）某商业综合体建筑，其办公区、酒店区、商业区分别设置消防控制室，并将办公区的消防控制室作为主消防控制室，其他两个作为分消防控制室。下列关于各分消防控制室内的消防设备之间的关系的说法，正确的是（ ）。",[488,490,492,494],{"key":20,"text":489,"correct":22},"不可以相互传输、显示状态信息，不应互相控制",{"key":24,"text":491,"correct":22},"不可以相互传输、显示状态信息，但应互相控制",{"key":28,"text":493,"correct":22},"可以相互传输、显示状态信息，也应互相控制",{"key":31,"text":495,"correct":26},"可以相互传输、显示状态信息，但不应互相控制",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":28,"analysis":33},931873,"（2015真题）用于保护1kV及以下的配电线路的电气火灾监控系统，其测温式电气火灾监控探测器的布置方式应采用（ ）",[500,502,504,506],{"key":20,"text":501,"correct":22},"非接触式",{"key":24,"text":503,"correct":22},"独立式",{"key":28,"text":505,"correct":26},"接触式",{"key":31,"text":507,"correct":22},"脱开式",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":31,"analysis":33},931874,"（2015真题）对于可能散发可燃气体密度小于空气密度的场所，可燃气体探测器应设置在被保护空间的（ ）。",[512,514,516,518],{"key":20,"text":513,"correct":22},"下部",{"key":24,"text":515,"correct":22},"中间部位",{"key":28,"text":517,"correct":22},"中间部位或下部",{"key":31,"text":519,"correct":26},"顶部",{"id":521,"libraryId":5,"type":84,"typeLabel":85,"stem":522,"options":523,"answer":534,"analysis":33},931875,"（2015真题）某单层洁净厂房，设有中央空调系统，用防火墙划分为两个防火分区，有一条输送带贯通两个防火分区，在输送带传过防火墙处的洞口设有专用防火闸门，厂房内设置IG 541组合分配灭火系统保护。下列关于该气体灭火系统启动联动控制的说法中，正确的有（ ）。",[524,526,528,530,532],{"key":20,"text":525,"correct":26},"应联动关闭输送带传过防火墙处的专用防火闸门",{"key":24,"text":527,"correct":26},"应联动关闭中央空调系统",{"key":28,"text":529,"correct":22},"应由一个火灾探测器动作启动系统",{"key":31,"text":531,"correct":26},"应联动打开气体灭火系统的选择阀",{"key":97,"text":533,"correct":22},"应联动打开空调系统穿越防火墙处的防火阀","ABD",{"id":536,"libraryId":5,"type":84,"typeLabel":85,"stem":537,"options":538,"answer":549,"analysis":33},931876,"（2015真题）某办公建筑设有自动喷水灭火系统、火灾自动报警系统和防排烟系统。建筑内下列消防系统中，启动联动控制不应受消防联动控制器处于自动或手动状态影响的有（ ）",[539,541,543,545,547],{"key":20,"text":540,"correct":22},"预作用式自动喷水灭火系统",{"key":24,"text":542,"correct":26},"湿式自动喷水灭火系统",{"key":28,"text":544,"correct":26},"干式自动喷水灭火系统",{"key":31,"text":546,"correct":26},"湿式室内消火栓系统",{"key":97,"text":548,"correct":22},"防排烟系统","BCD",{"id":551,"libraryId":5,"type":15,"typeLabel":16,"stem":552,"options":553,"answer":28,"analysis":33},931877,"（2016真题）某建筑高度为128m的民用建筑内设置的火灾自动报警系统，需要配备总数为1600点的联动控制模块，故应至少选择（ ）台消防联动控制器或联动型火灾报警控制器。",[554,556,557,558],{"key":20,"text":555,"correct":22},"1",{"key":24,"text":344,"correct":22},{"key":28,"text":342,"correct":26},{"key":31,"text":348,"correct":22},{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":24,"analysis":33},931878,"（2016真题）对于可能散发相对密度为1的可燃气体的场所，可燃气体探测器应设置在该场所室内空间的（ ）。",[563,565,567,568],{"key":20,"text":564,"correct":22},"中间高度位置",{"key":24,"text":566,"correct":26},"中间高度位置或顶部",{"key":28,"text":513,"correct":22},{"key":31,"text":569,"correct":22},"中间高度位置或下部",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":28,"analysis":33},931879,"（2016真题）消防控制室图形显示装置与火灾报警控制器、电气火灾监控器、消防联动控制器和（ ）应采用专用线路连接。",[574,576,578,580],{"key":20,"text":575,"correct":22},"区域显示器",{"key":24,"text":577,"correct":22},"消防应急广播扬声器",{"key":28,"text":579,"correct":26},"可燃气体报警控制器",{"key":31,"text":581,"correct":22},"火灾警报器",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":28,"analysis":33},931880,"（2016真题）下列关于电气火灾监控系统设置的做法中，错误的是（ ）。",[586,588,590,592],{"key":20,"text":587,"correct":22},"将剩余电流式电气火灾监控探测器的报警值设定为400mA",{"key":24,"text":589,"correct":22},"对于泄漏电流大于500mA的供电线路，将剩余电流式电气火灾监控探测器设置在下一级配电柜处",{"key":28,"text":591,"correct":26},"将非独立式电气火灾监控探测器接入火灾报警探测器的探测回路",{"key":31,"text":593,"correct":22},"将线型感温火灾探测器接入电气火灾监控器用于电气火灾监控",{"id":595,"libraryId":5,"type":84,"typeLabel":85,"stem":596,"options":597,"answer":534,"analysis":33},931881,"（2016真题）下列关于火灾声警报器的做法中,正确的有",[598,600,602,604,606],{"key":20,"text":599,"correct":26},"火灾自动报警系统能同时启动和停止所有火灾声警报器工作",{"key":24,"text":601,"correct":26},"火灾声警报器采用火灾报警控制器控制",{"key":28,"text":603,"correct":22},"火灾声警报与消防应急广播同步播放",{"key":31,"text":605,"correct":26},"学校阅览室，礼堂等公共场所采用具有同一种火灾变调声的火灾声警报器",{"key":97,"text":607,"correct":22},"教学楼使用警铃作为火灾声警报器",{"id":609,"libraryId":5,"type":15,"typeLabel":16,"stem":610,"options":611,"answer":28,"analysis":33},931882,"（2016真题）下列关于建筑防烟系统联动控制要求的做法中，错误的是（ ）。",[612,614,616,618],{"key":20,"text":613,"correct":22},"常闭加压送风口开启由其所在防火分区内两只独立火灾探测器的报警信号作为联动触发信号",{"key":24,"text":615,"correct":22},"加压送风机启动由其所在防火分区内的一只火灾探测器与一只手动火灾报警按钮的报警信号作为联动触发信号",{"key":28,"text":617,"correct":26},"楼梯间的前室或合用前室的加压送风系统中任一常闭加压送风口开启时，联动启动该楼梯间各楼层的前室及合用前室内的常闭加压送风口",{"key":31,"text":619,"correct":22},"对于防火分区跨越多个楼层的建筑，楼梯间的前室或合用前室内任一常闭加压送风口开启时联动启动该防火分区内全部楼层的楼梯间前室及合用前室内的常闭加压送风口",{"id":621,"libraryId":5,"type":15,"typeLabel":16,"stem":622,"options":623,"answer":31,"analysis":33},931883,"（2016真题）在有结构梁突出的顶棚上设置的点型感烟火灾探测器，当梁间净距小于（ ）m时，可忽略梁对探测器保护面积的影响。",[624,625,626,627],{"key":20,"text":342,"correct":22},{"key":24,"text":344,"correct":22},{"key":28,"text":348,"correct":22},{"key":31,"text":555,"correct":26},[629,632,635,638,641,644],{"id":15,"name":630,"category":7,"favorite":631},"领导干部任职前廉政法规知识测试题",92,{"id":633,"name":634,"category":7,"favorite":15},595,"建筑结构与设备",{"id":636,"name":637,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":639,"name":640,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":642,"name":643,"category":7,"favorite":8},534,"BIM工程师",{"id":645,"name":643,"category":7,"favorite":8},535]