[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-38":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":629},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,38,50,2960,[13,34,46,58,70,82,94,104,114,126,144,158,172,187,202,217,229,238,247,259,271,283,294,306,318,326,338,346,358,370,385,397,412,426,441,456,470,485,497,509,519,531,539,551,563,575,584,593,605,617],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},933554,1,"单选题","应急照明控制器备用电源应至少能保证应急照明控制器正常工作（ ）h。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","1",false,{"key":24,"text":25,"correct":22},"B","2",{"key":27,"text":28,"correct":22},"C","2．5",{"key":30,"text":31,"correct":32},"D","3",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},933555,"A型应急照明配电箱的输出回路不超过（ ）路。",[38,40,42,44],{"key":20,"text":39,"correct":22},"6",{"key":24,"text":41,"correct":32},"8",{"key":27,"text":43,"correct":22},"10",{"key":30,"text":45,"correct":22},"15",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":30,"analysis":33},933556,"除二类居住建筑外，高层建筑的（ ）和安全出口处应设灯光疏散指示标志。",[50,52,54,56],{"key":20,"text":51,"correct":22},"电梯前室",{"key":24,"text":53,"correct":22},"设备用房",{"key":27,"text":55,"correct":22},"地下室",{"key":30,"text":57,"correct":32},"疏散走道",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},933557,"绝大多数建筑内都应设置疏散照明，在不同的部位设置疏散照明的地面最低水平照度的要求有所不同。下列场所中的疏散照明的地面最低水平照度不符合规定的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"某多层针织品厂厂房内疏散走道的疏散照明的地面最低水平照度为 1.0lx",{"key":24,"text":65,"correct":22},"某超高层建筑中的避难走道的疏散照明的地面最低水平照度为 5.0lx",{"key":27,"text":67,"correct":32},"某老年人照料设施的楼梯间的地面最低水平照度为 5.0lx",{"key":30,"text":69,"correct":22},"某三级甲等医院的住院楼避难间的疏散照明的地面最低水平照度为 10.0lx",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},933558,"下列应急照明灯具中，属于按照工作方式分类的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"消防应急标志灯具",{"key":24,"text":77,"correct":32},"持续型消防应急灯具",{"key":27,"text":79,"correct":22},"自带电源型消防应急灯具",{"key":30,"text":81,"correct":22},"集中控制型消防应急灯具",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":27,"analysis":33},933559,"下列关于消防应急灯具的说法，正确的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"自带电源非集中控制型系统，通过应急照明分配电装置为消防应急灯具供电",{"key":24,"text":89,"correct":22},"集中电源非集中控制型系统连接的消防应急灯具自身带电源",{"key":27,"text":91,"correct":32},"集中电源集中控制型系统连接的消防应急灯具的电源由应急照明集中电源提供",{"key":30,"text":93,"correct":22},"自带电源集中控制型系统消防应急灯具由应急照明分配电装置供电",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},933560,"某建筑使用自带电源集中控制型消防应急照明和疏散指示系统，该系统在应急转换时，应急照明配电箱应保证转换时间不大于（ ）s。",[98,100,102,103],{"key":20,"text":99,"correct":32},"5",{"key":24,"text":101,"correct":22},"1．5",{"key":27,"text":31,"correct":22},{"key":30,"text":43,"correct":22},{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":30,"analysis":33},933561,"沿电气竖井垂直方向为不同楼层的灯具供电时，应急照明配电箱的每个输出回路在住宅建筑中的供电范围不宜超过（ ）层。",[108,109,110,112],{"key":20,"text":41,"correct":22},{"key":24,"text":43,"correct":22},{"key":27,"text":111,"correct":22},"12",{"key":30,"text":113,"correct":32},"18",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":30,"analysis":33},933562,"采用吸顶或吊装 式安装时，标志灯距安全出口或疏散门所在墙面不宜大于（）mm。",[118,120,122,124],{"key":20,"text":119,"correct":22},"100",{"key":24,"text":121,"correct":22},"20",{"key":27,"text":123,"correct":22},"30",{"key":30,"text":125,"correct":32},"50",{"id":127,"libraryId":5,"type":128,"typeLabel":129,"stem":130,"options":131,"answer":143,"analysis":33},933563,2,"多选题","下列关于消防应急照明和疏散指示系统灯具配电回路中，符合要求的（ ）。",[132,134,136,138,140],{"key":20,"text":133,"correct":32},"AC220V 或 DC216V 灯具的供电回路工作电流不宜大于10A",{"key":24,"text":135,"correct":22},"安全电压灯具的供电回路工作电流不宜大于10A",{"key":27,"text":137,"correct":32},"每个应急供电回路所配接的灯具数量不宜超过 60个",{"key":30,"text":139,"correct":32},"应急照明集中电源应经应急照明分配电装置配接消防应急灯具",{"key":141,"text":142,"correct":32},"E","应急照明集中电源、应急照明分配电装置及应急照明配电箱的输入及输出配电回路中不应装设剩余电流动作脱扣保护装置","ACDE",{"id":145,"libraryId":5,"type":128,"typeLabel":129,"stem":146,"options":147,"answer":157,"analysis":33},933564,"消防应急灯具是为人员疏散、灭火救援提供帮助的各类灯具，其包括（ ）。",[148,150,152,153,155],{"key":20,"text":149,"correct":32},"消防应急照明灯具",{"key":24,"text":151,"correct":22},"消防应急避难灯具",{"key":27,"text":75,"correct":32},{"key":30,"text":154,"correct":22},"消防应急照明标志复合灯具",{"key":141,"text":156,"correct":22},"消防应急救援灯具","AC",{"id":159,"libraryId":5,"type":128,"typeLabel":129,"stem":160,"options":161,"answer":143,"analysis":33},933565,"城市消防远程监控系统由（ ）组成。",[162,164,166,168,170],{"key":20,"text":163,"correct":32},"用户信息传输装置",{"key":24,"text":165,"correct":22},"用户服务系统",{"key":27,"text":167,"correct":32},"报警传输网络",{"key":30,"text":169,"correct":32},"监控中心",{"key":141,"text":171,"correct":32},"火警信息终端",{"id":173,"libraryId":5,"type":128,"typeLabel":129,"stem":174,"options":175,"answer":186,"analysis":33},933566,"城市消防远程监控系统的设计应能保证系统具有（ ）。",[176,178,180,182,184],{"key":20,"text":177,"correct":32},"实时性",{"key":24,"text":179,"correct":32},"可扩展性",{"key":27,"text":181,"correct":32},"安全性",{"key":30,"text":183,"correct":22},"全面性",{"key":141,"text":185,"correct":32},"适用性","ABCE",{"id":188,"libraryId":5,"type":128,"typeLabel":129,"stem":189,"options":190,"answer":201,"analysis":33},933567,"当城市消防远程监控系统采用有线通信方式传输时可选择（ ）接入方式。",[191,193,195,197,199],{"key":20,"text":192,"correct":32},"用户信息传输装置和报警受理系统通过电话用户线或电话中继线接入公用电话网",{"key":24,"text":194,"correct":32},"用户信息传输装置和报警受理系统通过电话用户线或光纤接入公用宽带网",{"key":27,"text":196,"correct":22},"用户信息传输装置和报警受理系统通过移动通信模块接入公用移动网",{"key":30,"text":198,"correct":32},"用户信息传输装置和报警受理系统通过模拟专线或数据专线接入专用通信网",{"key":141,"text":200,"correct":22},"用户信息传输装置和报警受理系统通过无线电收发设备接入无线专用通信网络","ABD",{"id":203,"libraryId":5,"type":128,"typeLabel":129,"stem":204,"options":205,"answer":216,"analysis":33},933568,"下列关于城市消防远程监控系统的性能要求，描述正确的有（ ）。",[206,208,210,212,214],{"key":20,"text":207,"correct":22},"监控中心能同时接收和处理不少于5个联网用户的火灾报警信息",{"key":24,"text":209,"correct":22},"监控中心向城市消防通信指挥中心或其他接处警中心转发经确认的火灾报警信息的时间不大于10s",{"key":27,"text":211,"correct":32},"监控中心与用户信息传输装置之间通信巡检周期不大于2h",{"key":30,"text":213,"correct":32},"监控中心的火灾报警信息和建筑消防设施运行状态信息的保存周期不少于1年",{"key":141,"text":215,"correct":32},"录音文件保存周期不少于6个月","CDE",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":27,"analysis":33},933569,"城市消防远程监控系统内监控中心的火灾报警信息、建筑消防设施运行状态信息等记录应进行备份，其保存周期不应少于（），录音文件的保存周期不应少于（）。",[221,223,225,227],{"key":20,"text":222,"correct":22},"6个月，1年",{"key":24,"text":224,"correct":22},"5年，1年",{"key":27,"text":226,"correct":32},"1年，6个月",{"key":30,"text":228,"correct":22},"1年，5年",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":24,"analysis":33},933571,"监控中心能同时接收和处理不少于（ ）个联网用户的火灾报警信息。",[233,234,235,236],{"key":20,"text":21,"correct":22},{"key":24,"text":31,"correct":32},{"key":27,"text":39,"correct":22},{"key":30,"text":237,"correct":22},"9",{"id":239,"libraryId":5,"type":15,"typeLabel":16,"stem":240,"options":241,"answer":30,"analysis":33},933572,"城市消防远程监控系统用户信息传输装置应具有主、备电源自动切换功能，备用电源的容量应能保证用户信息传输装置连续正常工作时间不小于（ ）h。",[242,243,245,246],{"key":20,"text":25,"correct":22},{"key":24,"text":244,"correct":22},"4",{"key":27,"text":39,"correct":22},{"key":30,"text":41,"correct":32},{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":27,"analysis":33},933573,"下列关于城市消防远程监控系统的电源要求的说法，错误的是（ ）。",[251,253,255,257],{"key":20,"text":252,"correct":22},"监控中心的电源应按所在建筑物的最高负荷等级配置，且不低于二级负荷",{"key":24,"text":254,"correct":22},"用户信息传输装置应有主电源与备用电源之间的自动切换装置",{"key":27,"text":256,"correct":32},"用户信息传输装置的主电源应有明显标识，并应直接使用电源插头，间接与消防电源连接",{"key":30,"text":258,"correct":22},"主电源与备电源的切换不应使传输装置产生误动作",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":27,"analysis":33},933574,"下列属于远程监控系统的网络安全应符合的要求是（ ）。",[263,265,267,269],{"key":20,"text":264,"correct":22},"数据库服务器应有备份功能",{"key":24,"text":266,"correct":22},"监控中心应有火灾报警信息接收的应急备份功能",{"key":27,"text":268,"correct":32},"对远程监控系统资源的访问应有身份认证和授权",{"key":30,"text":270,"correct":22},"应有系统运行记录",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":24,"analysis":33},933575,"日常防火巡查信息和消防设施定期检查信息应在检查完毕后的当日内发送至监控中心，其他发生变化的消防安全管理信息应在（ ）发送至监控中心。",[275,277,279,281],{"key":20,"text":276,"correct":22},"隔日",{"key":24,"text":278,"correct":32},"3日内",{"key":27,"text":280,"correct":22},"6日内",{"key":30,"text":282,"correct":22},"7日内",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":20,"analysis":33},933576,"用于接收、处理联网用户端的用户信息传输装置传输的火灾报警、建筑消防设施运行状态等信息，并能向城市消防通信指挥中心或其他接处警中心发送火灾报警信息的系统，为城市消防远程监控中心的（ ）。",[287,289,291,292],{"key":20,"text":288,"correct":32},"报警受理系统",{"key":24,"text":290,"correct":22},"信息查询系统",{"key":27,"text":165,"correct":22},{"key":30,"text":293,"correct":22},"通信服务系统",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":27,"analysis":33},933577,"城市消防远程监控系统监控中心的电源应按所在建筑物的最高负荷等级配置，且不低于（ ）级负荷。",[298,300,302,304],{"key":20,"text":299,"correct":22},"四级",{"key":24,"text":301,"correct":22},"三级",{"key":27,"text":303,"correct":32},"二级",{"key":30,"text":305,"correct":22},"一级",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":24,"analysis":33},933578,"城市消防远程监控系统的监控中心的电源应按所在建筑物的最高等级配置，且不应低于（ ）级负荷，并应保证不间断供电。",[310,312,314,316],{"key":20,"text":311,"correct":22},"一",{"key":24,"text":313,"correct":32},"二",{"key":27,"text":315,"correct":22},"三",{"key":30,"text":317,"correct":22},"四",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":24,"analysis":33},933579,"可以为城市消防通信指挥系统、重点单位信息管理系统提供联网单位的动态数据体现了城市消防远程监控系统的（ ）原则。",[322,323,324,325],{"key":20,"text":177,"correct":22},{"key":24,"text":185,"correct":32},{"key":27,"text":181,"correct":22},{"key":30,"text":179,"correct":22},{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":20,"analysis":33},933580,"下列关于监控中心内各系统功能的说法，错误的是（ ）。",[330,332,334,336],{"key":20,"text":331,"correct":32},"信息查询系统设置在城市消防通信指挥中心或其他接处警中心，用于接收并显示监控中心发送的火灾报警信息",{"key":24,"text":333,"correct":22},"用户服务系统能够为联网用户提供火灾报警、建筑消防设施运行状态、消防安全管理等相关信息服务",{"key":27,"text":335,"correct":22},"报警受理系统是用于接收、处理联网用户端的用户信息传输装置传输的火灾报警、建筑消防设施运行状态等信息，并能向城市消防通信指挥中心或其他接处警中心发送火灾报警信息的系统",{"key":30,"text":337,"correct":22},"数据库服务器用于存储和管理监控中心的各类信息数据",{"id":339,"libraryId":5,"type":15,"typeLabel":16,"stem":340,"options":341,"answer":24,"analysis":33},933581,"监控中心与用户信息传输装置之间通信巡检周期不大于（ ）h。",[342,343,344,345],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":32},{"key":27,"text":31,"correct":22},{"key":30,"text":244,"correct":22},{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":27,"analysis":33},933582,"某远程监控系统从用户信息传输装置获取火灾报警信息到监控中心接收显示的响应时间不应大于（ ）s，监控中心向城市消防通信指挥中心或其他接处警中心转发经确认的火灾报警信息的时间不应大于（ ）s。",[350,352,354,356],{"key":20,"text":351,"correct":22},"10；3",{"key":24,"text":353,"correct":22},"10；5",{"key":27,"text":355,"correct":32},"20；3",{"key":30,"text":357,"correct":22},"20；5",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":27,"analysis":33},933583,"城市消防远程监控系统能够对系统内各联网用户的火灾自动报警信息和建筑消防设施运行状态等信息进行数据采集、传输、接收、显示和（ ）。",[362,364,366,368],{"key":20,"text":363,"correct":22},"分析",{"key":24,"text":365,"correct":22},"解读",{"key":27,"text":367,"correct":32},"处理",{"key":30,"text":369,"correct":22},"消除",{"id":371,"libraryId":5,"type":128,"typeLabel":129,"stem":372,"options":373,"answer":384,"analysis":33},933584,"下列城市消防远程监控系统的分类中，按照信息传输方式分类有（ ）。",[374,376,378,380,382],{"key":20,"text":375,"correct":32},"有线城市消防远程监控系统",{"key":24,"text":377,"correct":22},"公用通信网的城市消防远程监控系统",{"key":27,"text":379,"correct":32},"无线城市消防远程监控系统",{"key":30,"text":381,"correct":22},"基于专用通信网的城市消防远程监控系统",{"key":141,"text":383,"correct":32},"有线／无线兼容的城市消防远程监控系统","ACE",{"id":386,"libraryId":5,"type":128,"typeLabel":129,"stem":387,"options":388,"answer":396,"analysis":33},933585,"城市消防远程监控系统的信息传输可采用有线通信或无线通信方式，当城市消防远程监控系统采用有线通信方式传输时可选择的接入方式有（ ）。",[389,390,391,393,394],{"key":20,"text":196,"correct":22},{"key":24,"text":194,"correct":32},{"key":27,"text":392,"correct":32},"用户信息传输装置和报警受理系统通过模拟专线或数据专线接入专用通信网络",{"key":30,"text":200,"correct":22},{"key":141,"text":395,"correct":22},"用户信息传输装置和报警受理系统通过集群语音通路或数据通路接入无线电集群专用通信网络","BC",{"id":398,"libraryId":5,"type":128,"typeLabel":129,"stem":399,"options":400,"answer":411,"analysis":33},933586,"目前常用灭火器类型有（ ）。",[401,403,405,407,409],{"key":20,"text":402,"correct":32},"干粉灭火器",{"key":24,"text":404,"correct":32},"二氧化碳灭火器",{"key":27,"text":406,"correct":22},"酸碱型灭火器",{"key":30,"text":408,"correct":22},"四氯化碳灭火器",{"key":141,"text":410,"correct":32},"洁净气体灭火器","ABE",{"id":413,"libraryId":5,"type":128,"typeLabel":129,"stem":414,"options":415,"answer":411,"analysis":33},933587,"下列灭火器中，适合扑灭电气类火灾的灭火器有（ ）。",[416,418,420,422,424],{"key":20,"text":417,"correct":32},"碳酸氢钠干粉灭火器",{"key":24,"text":419,"correct":32},"磷酸铵盐干粉灭火器",{"key":27,"text":421,"correct":22},"清水灭火器",{"key":30,"text":423,"correct":22},"泡沫灭火器",{"key":141,"text":425,"correct":32},"不带金属喇叭喷筒的二氧化碳灭火器",{"id":427,"libraryId":5,"type":128,"typeLabel":129,"stem":428,"options":429,"answer":440,"analysis":33},933588,"下列场所中，灭火器配置场所的火灾危险等级为中危险级的有（ ）。",[430,432,434,436,438],{"key":20,"text":431,"correct":22},"建筑面积为200m2的网吧",{"key":24,"text":433,"correct":32},"体育馆的观众厅",{"key":27,"text":435,"correct":22},"礼堂的舞台",{"key":30,"text":437,"correct":32},"建筑面积为1500m2的阅览室",{"key":141,"text":439,"correct":22},"汽车加油站","BD",{"id":442,"libraryId":5,"type":128,"typeLabel":129,"stem":443,"options":444,"answer":455,"analysis":33},933589,"灭火器的基本参数主要反映在灭火器的铭牌上，灭火器铭牌应包含的内容有（ ）。",[445,447,449,451,453],{"key":20,"text":446,"correct":32},"灭火器的生产年份",{"key":24,"text":448,"correct":32},"灭火器的使用温度范围",{"key":27,"text":450,"correct":32},"灭火器的灭火种类和灭火级别",{"key":30,"text":452,"correct":22},"灭火器的兼容性",{"key":141,"text":454,"correct":22},"灭火器的保护距离","ABC",{"id":457,"libraryId":5,"type":128,"typeLabel":129,"stem":458,"options":459,"answer":201,"analysis":33},933590,"下列关于灭火器配置场所计算单元的划分说法正确的是（ ）。",[460,462,464,466,468],{"key":20,"text":461,"correct":32},"对于不相邻的灭火器配置场所，应分别作为一个计算单元进行灭火器的配置设计计算",{"key":24,"text":463,"correct":32},"灭火器配置场所的危险等级和火灾种类均相同的相邻场所，可将一个楼层或一个防火分区作为一个计算单元",{"key":27,"text":465,"correct":22},"同一计算单元可以跨越防火分区和楼层",{"key":30,"text":467,"correct":32},"灭火器配置场所的危险等级或火灾种类不相同的场所，应分别作为一个计算单元 ．",{"key":141,"text":469,"correct":22},"一个计算单元只能含有一个灭火器配置场所",{"id":471,"libraryId":5,"type":128,"typeLabel":129,"stem":472,"options":473,"answer":484,"analysis":33},933591,"按照灭火器配置场所危险等级划分，下列属于中危险级的是（）。",[474,476,478,480,482],{"key":20,"text":475,"correct":22},"电影摄影棚",{"key":24,"text":477,"correct":22},"专用电子计算机房",{"key":27,"text":479,"correct":32},"机场检票厅",{"key":30,"text":481,"correct":32},"大型超市",{"key":141,"text":483,"correct":22},"普通住宅","CD",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":27,"analysis":33},933592,"变压器等设备的电气火灾属于（ ）。",[489,491,493,495],{"key":20,"text":490,"correct":22},"C类火灾",{"key":24,"text":492,"correct":22},"D类火灾",{"key":27,"text":494,"correct":32},"E类火灾",{"key":30,"text":496,"correct":22},"F类火灾",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":27,"analysis":33},933593,"某2层网吧，每层建筑面积为600m2，网吧内严格按照现行国家工程建设消防技术标准设置了各种消防设施，该网吧每层划分为一个计算单元，每层设置3个灭火器设置点，则下列说法中正确的是（）。",[501,503,505,507],{"key":20,"text":502,"correct":22},"每个计算单元的最小需配灭火级别为8.4A",{"key":24,"text":504,"correct":22},"每个灭火器设置点的最小需配灭火级别为6A",{"key":27,"text":506,"correct":32},"每个灭火器设置点可以配置2具MF／ABC5",{"key":30,"text":508,"correct":22},"每个灭火器设置点可以配置4具MF／ABC4",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":27,"analysis":33},933594,"某住宅建筑的下部为经营零食、水果、蔬菜的商业服务网点，该商业服务网点在选择灭火器时，不应选择（）。",[513,514,516,517],{"key":20,"text":419,"correct":22},{"key":24,"text":515,"correct":22},"水基型泡沫灭火器",{"key":27,"text":417,"correct":32},{"key":30,"text":518,"correct":22},"水基型水雾灭火器",{"id":520,"libraryId":5,"type":15,"typeLabel":16,"stem":521,"options":522,"answer":24,"analysis":33},933595,"灭火器内驱动气体的压力一般通过压力表显示出来，以便判断灭火器是否失效。下列灭火器中，不是通过压力表来显示压力的是（ ）。",[523,525,527,529],{"key":20,"text":524,"correct":22},"手提式干粉灭火器",{"key":24,"text":526,"correct":32},"手提式二氧化碳灭火器",{"key":27,"text":528,"correct":22},"手提式水基型灭火器（水雾）",{"key":30,"text":530,"correct":22},"手提式水基型灭火器（泡沫）",{"id":532,"libraryId":5,"type":15,"typeLabel":16,"stem":533,"options":534,"answer":24,"analysis":33},933596,"使用手提式干粉灭火器时，应在距燃烧处（ ）m左右，放下灭火器，先拔出保险销，一手握住开启压把，另一手握在喷射软管前端的喷嘴处。",[535,536,537,538],{"key":20,"text":25,"correct":22},{"key":24,"text":31,"correct":32},{"key":27,"text":99,"correct":22},{"key":30,"text":39,"correct":22},{"id":540,"libraryId":5,"type":15,"typeLabel":16,"stem":541,"options":542,"answer":24,"analysis":33},933597,"手提式二氧化碳灭火器要求每年至少检查一次，低于额定充装量的（ ）就应进行检修。",[543,545,547,549],{"key":20,"text":544,"correct":22},"90％",{"key":24,"text":546,"correct":32},"95％",{"key":27,"text":548,"correct":22},"80％",{"key":30,"text":550,"correct":22},"85％",{"id":552,"libraryId":5,"type":15,"typeLabel":16,"stem":553,"options":554,"answer":27,"analysis":33},933598,"手提式干粉灭火器设置在托架上时，其底部距地面的高度不宜小于（ ）m。",[555,557,559,561],{"key":20,"text":556,"correct":22},"0．04",{"key":24,"text":558,"correct":22},"0．06",{"key":27,"text":560,"correct":32},"0．08",{"key":30,"text":562,"correct":22},"0．05",{"id":564,"libraryId":5,"type":15,"typeLabel":16,"stem":565,"options":566,"answer":20,"analysis":33},933599,"下列关于机动车交易市场灭火器配置的说法，正确的是（ ）。",[567,569,571,573],{"key":20,"text":568,"correct":32},"机动车交易市场单具灭火器最小配置灭火级别为3A",{"key":24,"text":570,"correct":22},"机动车交易市场单具灭火器最小配置灭火级别为2A",{"key":27,"text":572,"correct":22},"机动车交易市场单具灭火器最小配置灭火级别为1A",{"key":30,"text":574,"correct":22},"机动车交易市场单位灭火级别最大保护面积为80m2／A",{"id":576,"libraryId":5,"type":15,"typeLabel":16,"stem":577,"options":578,"answer":27,"analysis":33},933600,"某高度为16m的4层建筑，耐火等级为二级，每层划分为6个计算单元，则该建筑最低应配备（ ）具灭火器。",[579,580,581,583],{"key":20,"text":39,"correct":22},{"key":24,"text":111,"correct":22},{"key":27,"text":582,"correct":32},"48",{"key":30,"text":244,"correct":22},{"id":585,"libraryId":5,"type":15,"typeLabel":16,"stem":586,"options":587,"answer":30,"analysis":33},933601,"某多层民用建筑的第三层为网吧，建筑面积600m2，该场所设有室内消火栓、自动喷水灭火系统、火灾自动报警系统及防排烟系统，该网吧的最小需配灭火级别为（ ）A。",[588,589,591,592],{"key":20,"text":45,"correct":22},{"key":24,"text":590,"correct":22},"16",{"key":27,"text":39,"correct":22},{"key":30,"text":41,"correct":32},{"id":594,"libraryId":5,"type":15,"typeLabel":16,"stem":595,"options":596,"answer":20,"analysis":33},933602,"某二级耐火等级的3层旅馆，客房数为40间，设有室内消火栓系统、自动喷水灭火系统、火灾自动报警系统等，下列关于该场所公共活动用房中配置手提式灭火器的说法。正确的是（ ）。",[597,599,601,603],{"key":20,"text":598,"correct":32},"单具灭火器的最大保护距离为20m",{"key":24,"text":600,"correct":22},"单具灭火器的最低配置基准应为3A",{"key":27,"text":602,"correct":22},"单具灭火器的最大保护距离为40m",{"key":30,"text":604,"correct":22},"单具灭火器的最低配置基准应为4A",{"id":606,"libraryId":5,"type":15,"typeLabel":16,"stem":607,"options":608,"answer":27,"analysis":33},933603,"某推车式多功能灭火剂的充装量为20kg，该灭火器的型号可表示为（ ）。",[609,611,613,615],{"key":20,"text":610,"correct":22},"MFT20",{"key":24,"text":612,"correct":22},"MF／ABC20",{"key":27,"text":614,"correct":32},"MFT／ABC20",{"key":30,"text":616,"correct":22},"MST20",{"id":618,"libraryId":5,"type":15,"typeLabel":16,"stem":619,"options":620,"answer":30,"analysis":33},933604,"下列不是灭火器选择应考虑的因素是（ ）。",[621,623,625,627],{"key":20,"text":622,"correct":22},"灭火器配置场所的火灾种类",{"key":24,"text":624,"correct":22},"灭火器设置点的环境温度",{"key":27,"text":626,"correct":22},"使用灭火器人员的体能",{"key":30,"text":628,"correct":32},"灭火器设置点的数量",[630,633,636,639,642,645],{"id":15,"name":631,"category":7,"favorite":632},"领导干部任职前廉政法规知识测试题",92,{"id":634,"name":635,"category":7,"favorite":15},595,"建筑结构与设备",{"id":637,"name":638,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":640,"name":641,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":643,"name":644,"category":7,"favorite":8},534,"BIM工程师",{"id":646,"name":644,"category":7,"favorite":8},535]