[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-36":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":657},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,36,50,2960,[13,34,46,58,70,82,94,106,118,130,142,154,166,177,187,199,211,223,233,245,257,275,288,303,318,333,348,362,377,392,407,421,436,450,465,479,494,508,523,535,547,555,567,579,589,601,613,621,633,645],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},933454,1,"单选题","下列不属于不宜选择点型离子感烟火灾探测器的是（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","相对湿度经常大于95％的场所",false,{"key":24,"text":25,"correct":22},"B","在正常情况下有烟滞留的场所",{"key":27,"text":28,"correct":22},"C","有大量粉尘、水雾滞留的场所",{"key":30,"text":31,"correct":32},"D","高海拔地区",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},933455,"点型火灾探测器是火灾报警系统中使用最广泛的一种探测器，下列关于点型火灾探测器设置的说法中，错误的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":32},"在有梁的顶棚上设置点型感烟火灾探测器，安装高度10m，梁高180mm，此时在确定一只探测器的保护面积时应考虑梁的影响",{"key":24,"text":41,"correct":22},"一个房间室内净高4m，该房间被高大书架分隔出一个小区域，书架距屋顶的距离为0．15m，此分隔出的小区域至少安装一只点型探测器",{"key":27,"text":43,"correct":22},"点型探测器宜接近回风口安装",{"key":30,"text":45,"correct":22},"点型探测器确需倾斜安装时，倾斜角度不应大于45。",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},933456,"当消防控制室内的设备面盘排列长度大于（ ）m时，应在其两端设置宽度不小于（ ）m的通道。",[50,52,54,56],{"key":20,"text":51,"correct":22},"3，0．5",{"key":24,"text":53,"correct":32},"4，1．0",{"key":27,"text":55,"correct":22},"2，1．5",{"key":30,"text":57,"correct":22},"3，1．0",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},933457,"在湿式自动喷水灭火系统中，下列方式不能启动喷淋消防泵的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"湿式报警阀压力开关的动作信号",{"key":24,"text":65,"correct":32},"两个探测器的动作信号",{"key":27,"text":67,"correct":22},"在消防联动控制器上的手动控制盘直接手动操作",{"key":30,"text":69,"correct":22},"在泵房内水泵控制柜上手动操作",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":30,"analysis":33},933458,"关于可燃气体探测器的设置，叙述错误的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"线型可燃气体探测器的保护区域长度不宜大于60m",{"key":24,"text":77,"correct":22},"可燃气体探测器宜设置在可能产生可燃气体的部位附近",{"key":27,"text":79,"correct":22},"点型可燃气体探测器的保护半径，应符合现行国家标准《石油化工可燃气体和有毒气体检测报警设计规范》（GB 50493--2009）的有关规定",{"key":30,"text":81,"correct":32},"探测气体密度与空气密度相当的可燃气体探测器可设置在被保护空间的下部",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":30,"analysis":33},933459,"设有火灾自动报警系统时，（ ）的报警信息和故障信息应在消防控制室图形显示装置或集中火灾报警控制器上显示。",[86,88,90,92],{"key":20,"text":87,"correct":22},"剩余电流式电气火灾监控探测器",{"key":24,"text":89,"correct":22},"测温式电气火灾监控探测器",{"key":27,"text":91,"correct":22},"测烟式电气火灾监控探测器",{"key":30,"text":93,"correct":32},"独立式电气火灾监控探测器",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},933460,"不符合手动火灾报警按钮设置要求的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"列车上设置的手动火灾报警按钮，应设置在每节车厢的出入口和中间部位",{"key":24,"text":101,"correct":32},"从一个防火分区内的任何位置到最邻近的手动火灾报警按钮的步行距离可以是50m",{"key":27,"text":103,"correct":22},"手动火灾报警按钮宜设置在疏散通道或出入口处",{"key":30,"text":105,"correct":22},"每个防火分区应至少设置一只手动火灾报警按钮",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":27,"analysis":33},933461,"下列关于线型光束感烟火灾探测器的安装，不符合规范要求的是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"探测器的光束轴线至顶棚的垂直距离为0．7m",{"key":24,"text":113,"correct":22},"探测器距地高度为15m",{"key":27,"text":115,"correct":32},"相邻两组探测器的水平距离为15m",{"key":30,"text":117,"correct":22},"探测器至侧墙水平距离为5m",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":30,"analysis":33},933462,"点型感烟火灾探测器的最大适用高度为（ ）m。",[122,124,126,128],{"key":20,"text":123,"correct":22},"6",{"key":24,"text":125,"correct":22},"8",{"key":27,"text":127,"correct":22},"10",{"key":30,"text":129,"correct":32},"12",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":30,"analysis":33},933463,"由于分期建设而采用了不同企业的产品，则火灾自动报警系统应选择（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"消防联动报警系统",{"key":24,"text":137,"correct":22},"区域报警系统",{"key":27,"text":139,"correct":22},"集中报警系统",{"key":30,"text":141,"correct":32},"控制中心报警系统",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":27,"analysis":33},933464,"下列场所不适合选择感温火灾探测器的是（ ）。",[146,148,150,152],{"key":20,"text":147,"correct":22},"相对湿度经常大于95％",{"key":24,"text":149,"correct":22},"厨房",{"key":27,"text":151,"correct":32},"计算机房",{"key":30,"text":153,"correct":22},"锅炉房",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":30,"analysis":33},933465,"根据《火灾自动报警系统设计规范》GB50116—2013的规定，安全出口指示标志灯具不宜与（）设置在同一面墙上。",[158,160,162,164],{"key":20,"text":159,"correct":22},"手动火灾报警按钮",{"key":24,"text":161,"correct":22},"消防应急广播扬声器",{"key":27,"text":163,"correct":22},"壁挂式区域显示器",{"key":30,"text":165,"correct":32},"火灾光警报器",{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":27,"analysis":33},933466,"某探测区域建筑面积为240m2，设置点型感烟火灾探测器，探测器的保护面积为60m2，修正系数为1．0，则该探测区域至少需要设置（）个探测器。",[170,172,174,176],{"key":20,"text":171,"correct":22},"1",{"key":24,"text":173,"correct":22},"2",{"key":27,"text":175,"correct":32},"4",{"key":30,"text":123,"correct":22},{"id":178,"libraryId":5,"type":15,"typeLabel":16,"stem":179,"options":180,"answer":24,"analysis":33},933467,"某多功能厅设置了火灾自动报警系统。该多功能厅地面面积为 360 平方米，房间高度为 5m，可同时容纳 300 人，屋顶为平屋顶。该多功能厅内设置点型感烟火灾探测器，则该多功能厅内至少需要设置（ ）只感烟火灾探测器。",[181,183,184,186],{"key":20,"text":182,"correct":22},"7",{"key":24,"text":123,"correct":32},{"key":27,"text":185,"correct":22},"5",{"key":30,"text":175,"correct":22},{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":24,"analysis":33},933468,"仅需要报警，不需要联动自动消防设备的保护对象宜采用（ ）报警系统。",[191,193,195,197],{"key":20,"text":192,"correct":22},"集中",{"key":24,"text":194,"correct":32},"区域",{"key":27,"text":196,"correct":22},"控制中心",{"key":30,"text":198,"correct":22},"分散",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":30,"analysis":33},933469,"线型光束感烟火灾探测器的光束轴线至顶棚的垂直距离宜为（ ）。",[203,205,207,209],{"key":20,"text":204,"correct":22},"0．1～0．5m",{"key":24,"text":206,"correct":22},"0．1～1．0m",{"key":27,"text":208,"correct":22},"0．3～0．5m",{"key":30,"text":210,"correct":32},"0．3～1．0m",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":24,"analysis":33},933470,"下列场所不宜选择线型光束感烟火灾探测器的是（ ）。",[215,217,219,221],{"key":20,"text":216,"correct":22},"无遮挡的大空间",{"key":24,"text":218,"correct":32},"可能产生蒸气和油雾的场所",{"key":27,"text":220,"correct":22},"有特殊要求的房间",{"key":30,"text":222,"correct":22},"电缆隧道",{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":30,"analysis":33},933471,"消防控制室内值班人员经常工作的一面，设备面盘至墙的距离不应小于（ ）m。",[227,228,230,231],{"key":20,"text":171,"correct":22},{"key":24,"text":229,"correct":22},"1．5",{"key":27,"text":173,"correct":22},{"key":30,"text":232,"correct":32},"3",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":27,"analysis":33},933472,"某建筑物内设有火灾自动报警系统，下列关于火灾探测器的安装质量检查结果中，不符合安装要求的是（）。",[237,239,241,243],{"key":20,"text":238,"correct":22},"安装在顶棚上的点型感烟探测器距多孔送风顶棚口的水平距离为1m",{"key":24,"text":240,"correct":22},"安装在宽度为2m的内走道顶棚上的点型感温探测器的间距为9m",{"key":27,"text":242,"correct":32},"在中庭安装的一对红外光束感烟探测器距地面的垂直距离为21m，且在这一高度上没有任何遮挡物",{"key":30,"text":244,"correct":22},"会议室内感烟探测器的报警确认灯朝向会议室的门口",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":24,"analysis":33},933473,"某商场中庭开口部位设置用作防火分隔的防火卷帘。根据《火灾自动报警系统设计规范》（GB50116—2013）规定，关于该防火卷帘联动控制的说法，正确的是（）。",[249,251,253,255],{"key":20,"text":250,"correct":22},"应由设置在防火卷帘所在防火分区内任一专门联动防火卷帘的感温火灾探测器的报警信号作为联动触发信号，联动控制防火卷帘直接下降到楼板面",{"key":24,"text":252,"correct":32},"防火卷帘下降到楼板面的动作信号和直接与防火卷帘控制器连接的火灾探测器报警信号，应反馈至消防控制室内的消防联动控制器",{"key":27,"text":254,"correct":22},"应由防火卷帘一侧距卷帘纵深0．5～5m内设置的感温火灾探测器报警信号作为联动触发信号，联动控制防火卷帘直接下降到楼板面",{"key":30,"text":256,"correct":22},"防火卷帘两侧设置的手动控制按钮应能控制防火卷帘的升降，在消防控制室内消防联动控制器上不得手动控制防火卷帘的降落",{"id":258,"libraryId":5,"type":259,"typeLabel":260,"stem":261,"options":262,"answer":274,"analysis":33},933474,2,"多选题","根据《火灾自动报警系统设计规范》（GB50116—2013）的规定，控制设备除应采用消防联动控制方式外，还应在消防控制室设置手动直接控制装置的有（ ）。",[263,265,267,269,271],{"key":20,"text":264,"correct":32},"消防水泵",{"key":24,"text":266,"correct":32},"防烟风机",{"key":27,"text":268,"correct":22},"挡烟垂壁",{"key":30,"text":270,"correct":22},"防火卷帘",{"key":272,"text":273,"correct":32},"E","排烟风机","ABE",{"id":276,"libraryId":5,"type":259,"typeLabel":260,"stem":277,"options":278,"answer":287,"analysis":33},933475,"电气火灾监控探测器按照不同的分类方式可以分为不同的种类，按照工作原理分类可分为（ ）。",[279,280,281,283,285],{"key":20,"text":93,"correct":22},{"key":24,"text":89,"correct":32},{"key":27,"text":282,"correct":22},"非独立式电气火灾监控探测器",{"key":30,"text":284,"correct":32},"故障电弧式电气火灾监控探测器",{"key":272,"text":286,"correct":32},"剩余电流保护式电气火灾监控探测器","BDE",{"id":289,"libraryId":5,"type":259,"typeLabel":260,"stem":290,"options":291,"answer":302,"analysis":33},933476,"下列建筑或场所中，应设置火灾自动报警系统的有（ ）。",[292,294,296,298,300],{"key":20,"text":293,"correct":22},"总建筑面积为3000m2的制衣厂房",{"key":24,"text":295,"correct":32},"歌舞娱乐放映游艺场所",{"key":27,"text":297,"correct":32},"中型幼儿园的儿童用房",{"key":30,"text":299,"correct":32},"层数为3层，每层建筑面积为1200m2的电子厂房",{"key":272,"text":301,"correct":32},"单层占地面积为800m2的卷烟仓库","BCDE",{"id":304,"libraryId":5,"type":259,"typeLabel":260,"stem":305,"options":306,"answer":317,"analysis":33},933477,"下列关于线型光束感烟火灾探测器的做法中，错误的有（ ）。",[307,309,311,313,315],{"key":20,"text":308,"correct":32},"探测器的光束轴线至顶棚的垂直距离为1．2m",{"key":24,"text":310,"correct":32},"探测器距地高度为24m",{"key":27,"text":312,"correct":32},"探测器的设接收端能受到日光和人工光源直接照射",{"key":30,"text":314,"correct":32},"探测器的发射器和接收器之间的距离为120m",{"key":272,"text":316,"correct":22},"探测器至侧墙水平距离为6m","ABCD",{"id":319,"libraryId":5,"type":259,"typeLabel":260,"stem":320,"options":321,"answer":332,"analysis":33},933478,"某房间划分为一个探测区域，房间内设置点型感烟火灾探测器，则该房间内设置探测器的数量与哪些因素有关（ ）。",[322,324,326,328,330],{"key":20,"text":323,"correct":32},"探测区域面积",{"key":24,"text":325,"correct":32},"探测器的安装高度",{"key":27,"text":327,"correct":22},"房间疏散门的数量",{"key":30,"text":329,"correct":32},"房间顶棚的坡度",{"key":272,"text":331,"correct":22},"房间有无排烟窗","ABD",{"id":334,"libraryId":5,"type":259,"typeLabel":260,"stem":335,"options":336,"answer":347,"analysis":33},933479,"某信息机房设置二氧化碳气体灭火系统进行保护，防护区内平时无人工作。下列有关该防护区系统设计及设备动作的说法，不正确的有（ ）。",[337,339,341,343,345],{"key":20,"text":338,"correct":22},"防护区内一只感烟火灾探测器和与感烟火灾探测器相邻的一只感温火灾探测器发出的报警信号可以作为系统的联动触发信号",{"key":24,"text":340,"correct":32},"系统收到首个联动触发信号后，防护区气体放指示灯动作",{"key":27,"text":342,"correct":32},"系统收到后续联动触发信号后，系统联动关闭防护区的送、排风机，停止通风空气调节系统",{"key":30,"text":344,"correct":22},"系统设置无延迟的喷射",{"key":272,"text":346,"correct":32},"系统联动控制应可以关闭该防护区与相邻防护区内的门、窗","BCE",{"id":349,"libraryId":5,"type":259,"typeLabel":260,"stem":350,"options":351,"answer":317,"analysis":33},933480,"下列关于火灾警报器和消防应急广播的说法，正确的有（ ）。",[352,354,356,358,360],{"key":20,"text":353,"correct":32},"火灾声警报器设置带有语音提示功能时，应同时设置语音同步器",{"key":24,"text":355,"correct":32},"控制中心报警系统应设置消防应急广播",{"key":27,"text":357,"correct":32},"在控制中心报警系统中，火灾声警报应与消防应急广播交替循环播放",{"key":30,"text":359,"correct":32},"同一建筑内设置多个火灾声警报器时，火灾自动报警系统应能同时启动和停止所有火灾声警报器工作",{"key":272,"text":361,"correct":22},"公共场所宜设置具有多种火灾变调声的火灾声警报器",{"id":363,"libraryId":5,"type":259,"typeLabel":260,"stem":364,"options":365,"answer":376,"analysis":33},933481,"火灾报警与消防联动控制系统的布线可选择（ ）。",[366,368,370,372,374],{"key":20,"text":367,"correct":32},"铜芯绝缘电线",{"key":24,"text":369,"correct":32},"铜芯电缆",{"key":27,"text":371,"correct":22},"同轴电缆",{"key":30,"text":373,"correct":22},"铝芯电缆",{"key":272,"text":375,"correct":22},"铝芯绝缘电线","AB",{"id":378,"libraryId":5,"type":259,"typeLabel":260,"stem":379,"options":380,"answer":391,"analysis":33},933482,"下列关于防火卷帘的消防联动控制设计描述正确的是（ ）",[381,383,385,387,389],{"key":20,"text":382,"correct":32},"防火卷帘控制器直接连接在火灾探测器上时，防火卷帘控制器在接收到满足逻辑关系的联动触发信号后，可以直接控制防火卷帘的下降，不论消防联动控制器是否处于自动状态",{"key":24,"text":384,"correct":22},"当防火卷帘设置在疏散通道上时，由防火分区内任两只独立的感烟火灾探测器或任一只专门用于联动防火卷帘的感温火灾探测器的报警信号作为防火卷帘下降的首个联动触发信号，联动控制防火卷帘下降至距楼板1．8m处",{"key":27,"text":386,"correct":32},"任一只专门用于联动防火卷帘的感温火灾探测器的报警信号作为防火卷帘下降的后续联动触发信号，联动防火卷帘下降到楼板",{"key":30,"text":388,"correct":32},"在防火卷帘任一侧距卷帘纵深0．5～5m内应设置不少于2只专门用于联动防火卷帘的感温火灾探测器",{"key":272,"text":390,"correct":32},"非疏散通道上设置的防火卷帘，由防火卷帘所在防火分区内任两只独立的火灾探测器的报警信号，作为防火卷帘下降的联动触发信号，联动控制防火卷帘下降至楼板","ACDE",{"id":393,"libraryId":5,"type":259,"typeLabel":260,"stem":394,"options":395,"answer":406,"analysis":33},933483,"下列关于火灾自动报警系统说法正确的是（）。",[396,398,400,402,404],{"key":20,"text":397,"correct":22},"火灾自动报警系统应设置火灾声光警报器，并应在确认火灾后启动发生火灾的防火分区内所有的火灾声光警报器",{"key":24,"text":399,"correct":32},"消防联动控制器应具有发出联动控制信号强制所有电梯停于首层或电梯转换层的功能。",{"key":27,"text":401,"correct":22},"在疏散通道上设置的防火卷帘的任一侧距卷帘纵深0.5-5m内应设置不少于两只专门用于联动防火卷帘的感烟火灾探测器",{"key":30,"text":403,"correct":32},"排烟风机入口处的总管上设置的280℃排烟防火阀在关闭后应直接联锁控制风机停止",{"key":272,"text":405,"correct":22},"消防联动控制器应具有切断火灾区域及相关区域的所有电源的功能，当需要切断正常照明时，宜在自动喷淋系统、消火栓系统动作前切断。","BD",{"id":408,"libraryId":5,"type":259,"typeLabel":260,"stem":409,"options":410,"answer":391,"analysis":33},933484,"某单位拟新建图书馆，委托某设计单位进行图书馆防烟排烟系统的工程设计，下列关于加压送风机和排烟风机的启动方式的设计方案中，正确的有（）。",[411,413,415,417,419],{"key":20,"text":412,"correct":32},"通过现场的风机控制柜直接手动启动",{"key":24,"text":414,"correct":22},"同一防火分区内不同防烟分区的2只独立感烟探测器报警后，直接联动启动排烟风机",{"key":27,"text":416,"correct":32},"同一防火分区内2只独立感烟探测器，探测器报警后，联动启动楼梯间的加压送风机",{"key":30,"text":418,"correct":32},"同一防火分区内2只独立感温探测器，探测器报警后，联动启动楼梯间的加压送风机",{"key":272,"text":420,"correct":32},"通过消防控制室的消防联动控制器的手动控制盘直接启动",{"id":422,"libraryId":5,"type":259,"typeLabel":260,"stem":423,"options":424,"answer":435,"analysis":33},933485,"关于自动控制的水幕系统的联动控制设计的说法，符合规范要求的有（）。",[425,427,429,431,433],{"key":20,"text":426,"correct":32},"自动控制的水幕系统用于防火卷帘的保护时，由防火卷帘下落到楼地面的动作信号与本报警区域内任一火灾探测器或手动火灾报警按钮的报警信号（“与”逻辑）作为水幕阀组启动的联动触发信号",{"key":24,"text":428,"correct":22},"自动控制的水幕系统用于防火卷帘的保护时，由该报警区域内任意两只感温火灾探测器的火灾报警信号（“与”逻辑）作为水幕阀组启动的联动触发信号",{"key":27,"text":430,"correct":22},"仅用水幕系统作为防火分隔时，由该报警区域内任意两只感烟火灾探测器的火灾报警信号（“与”逻辑）作为水幕阀组启动的联动触发信号",{"key":30,"text":432,"correct":22},"仅用水幕系统作为防火分隔时，由任一火灾探测器或手动火灾报警按钮的报警信号（“与”逻辑）作为水幕阀组启动的联动触发信号",{"key":272,"text":434,"correct":32},"仅用水幕系统作为防火分隔时，由该报警区域内两只独立的感温火灾探测器的火灾报警信号（“与”逻辑）作为水幕阀组启动的联动触发信号","AE",{"id":437,"libraryId":5,"type":259,"typeLabel":260,"stem":438,"options":439,"answer":347,"analysis":33},933486,"下列材料可以用来制作挡烟垂壁的有（ ）。",[440,442,444,446,448],{"key":20,"text":441,"correct":22},"纸面石膏板",{"key":24,"text":443,"correct":32},"防火玻璃",{"key":27,"text":445,"correct":32},"不燃无机复合板",{"key":30,"text":447,"correct":22},"矿棉板",{"key":272,"text":449,"correct":32},"钢板",{"id":451,"libraryId":5,"type":259,"typeLabel":260,"stem":452,"options":453,"answer":464,"analysis":33},933487,"下列关于排烟管道的说法，正确的有（ ）。",[454,456,458,460,462],{"key":20,"text":455,"correct":22},"排烟管道采用土建管道时，管道设计风速不应大于15m／s",{"key":24,"text":457,"correct":22},"当吊顶内有可燃物时，吊顶内的排烟管道应采用难燃材料进行隔热，并应与可燃物保持不小于150mm的距离",{"key":27,"text":459,"correct":32},"排烟管道井应采用耐火极限不小于1．00h的隔墙与相邻区域分隔",{"key":30,"text":461,"correct":22},"排烟管道井，当墙上必须设置检修门时，应采用丙级防火门",{"key":272,"text":463,"correct":32},"竖向设置的排烟管道应设置在独立的管道井内，排烟管道的耐火极限不应低于0．50h","CE",{"id":466,"libraryId":5,"type":259,"typeLabel":260,"stem":467,"options":468,"answer":406,"analysis":33},933488,"汽车库、修车库防烟排烟设置要求，排烟风机可采用（ ）．并应保证280℃时能连续工作30min。",[469,471,473,475,477],{"key":20,"text":470,"correct":22},"防爆风机",{"key":24,"text":472,"correct":32},"离心风机",{"key":27,"text":474,"correct":22},"混流风机",{"key":30,"text":476,"correct":32},"排烟轴流风机",{"key":272,"text":478,"correct":22},"吊装风机",{"id":480,"libraryId":5,"type":259,"typeLabel":260,"stem":481,"options":482,"answer":493,"analysis":33},933489,"下列关于机械加压送风的设置要求的说法正确的是（ ）。",[483,485,487,489,491],{"key":20,"text":484,"correct":32},"机械加压送风机的进风口宜直通室外",{"key":24,"text":486,"correct":22},"采用机械加压送风的场所可以设置百叶窗",{"key":27,"text":488,"correct":32},"机械加压送风口的风速不宜大于7m／s",{"key":30,"text":490,"correct":22},"机械加压送风管道应独立设置在管道井内",{"key":272,"text":492,"correct":32},"未设置在管道井内的加压送风管，其耐火极限不应小于1．0h","ACE",{"id":495,"libraryId":5,"type":259,"typeLabel":260,"stem":496,"options":497,"answer":317,"analysis":33},933490,"下列厂房或仓库应设置排烟设施的是（ ）。",[498,500,502,504,506],{"key":20,"text":499,"correct":32},"人员或可燃物较多的丙类生产场所，丙类厂房内建筑面积大于300m2且经常有人停留或可燃物较多的地上房间",{"key":24,"text":501,"correct":32},"建筑面积大于5000m2的丁类生产车间",{"key":27,"text":503,"correct":32},"占地面积大于1000m2的丙类仓库",{"key":30,"text":505,"correct":32},"高度33m的厂房内长度25m的疏散走道",{"key":272,"text":507,"correct":22},"高度20m的仓库内长度30m的疏散走道",{"id":509,"libraryId":5,"type":259,"typeLabel":260,"stem":510,"options":511,"answer":522,"analysis":33},933491,"下列建筑中，防烟楼梯间可不设置防烟系统的是（ ）。",[512,514,516,518,520],{"key":20,"text":513,"correct":22},"建筑高度为35m的丙类厂房，楼梯间独立前室设置的不同朝向可开启外窗的面积之和为3m2",{"key":24,"text":515,"correct":32},"建筑高度为32m的综合楼，楼梯间独立前室的两个方向分别设有一个面积为3m2的可开启外窗",{"key":27,"text":517,"correct":32},"建筑高度为28m的医院病房楼，楼梯间与消防电梯的合用前室采用全敞开的凹廊",{"key":30,"text":519,"correct":22},"建筑高度为54m的商店建筑，楼梯间的独立前室采用全敞开的阳台",{"key":272,"text":521,"correct":22},"建筑高度为36m的住宅，楼梯间与消防电梯的合用前室设有一个面积为3m2的可开启外窗","BC",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":24,"analysis":33},933492,"某二级耐火等级单层丙类厂房，室内净空高度为5．5m，设置机械排烟系统，根据《建筑防烟排烟系统技术标准》GB51251—2017的规定，该厂房内一个防烟分区的最大允许建筑面积不应大于（ ）m2。",[527,529,531,533],{"key":20,"text":528,"correct":22},"500",{"key":24,"text":530,"correct":32},"1000",{"key":27,"text":532,"correct":22},"2000",{"key":30,"text":534,"correct":22},"3000",{"id":536,"libraryId":5,"type":15,"typeLabel":16,"stem":537,"options":538,"answer":24,"analysis":33},933493,"下列关于防烟系统的说法中，正确的是（ ）。",[539,541,543,545],{"key":20,"text":540,"correct":22},"某综合办公楼，建筑高度为60m，合用前室顶部设置机械加压送风口，防烟楼梯间可只采用自然通风的防烟方式",{"key":24,"text":542,"correct":32},"某底部为商业服务网点的住宅，建筑高度为60m，防烟前室顶部设置机械加压送风口，防烟楼梯间可只采用自然通风的防烟方式",{"key":27,"text":544,"correct":22},"某丙类厂房，建筑高度为60m，合用前室顶部设置机械加压送风口，防烟楼梯间可只采用自然通风的防烟方式",{"key":30,"text":546,"correct":22},"某公寓，建筑高度为60m，合用前室顶部设置机械加压送风口，防烟楼梯间可只采用自然通风的防烟方式",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":30,"analysis":33},933494,"某办公综合楼，建筑高度160m，设置防烟排烟系统，排烟系统竖向独立分段设置时，最少应分成（ ）段。",[551,552,553,554],{"key":20,"text":171,"correct":22},{"key":24,"text":173,"correct":22},{"key":27,"text":232,"correct":22},{"key":30,"text":175,"correct":32},{"id":556,"libraryId":5,"type":15,"typeLabel":16,"stem":557,"options":558,"answer":27,"analysis":33},933495,"为了保证防烟楼梯间及其前室、消防电梯间前室和合用前室的正压值，防止正压值过大而导致疏散门难以推开，应在防烟楼梯间与前室，前室与走道之间设置余压阀，控制余压阀两侧正压间的压力差不超过（ ）Pa。",[559,561,563,565],{"key":20,"text":560,"correct":22},"30",{"key":24,"text":562,"correct":22},"40",{"key":27,"text":564,"correct":32},"50",{"key":30,"text":566,"correct":22},"55",{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":27,"analysis":33},933496,"人防工程下列部位可以不设置机械排烟设施的是（ ）。",[571,573,575,577],{"key":20,"text":572,"correct":22},"建筑面积大于50m2，且经常有人停留或可燃物较多的房间、大厅",{"key":24,"text":574,"correct":22},"丙、丁类生产车间",{"key":27,"text":576,"correct":32},"总长度10m的疏散走道",{"key":30,"text":578,"correct":22},"电影放映间、舞台等",{"id":580,"libraryId":5,"type":15,"typeLabel":16,"stem":581,"options":582,"answer":24,"analysis":33},933497,"相邻防烟分区之间应设置挡烟垂壁，其中顶板下凸出不小于（ ）mm的结构梁，可作为挡烟垂壁。",[583,585,586,588],{"key":20,"text":584,"correct":22},"300",{"key":24,"text":528,"correct":32},{"key":27,"text":587,"correct":22},"600",{"key":30,"text":530,"correct":22},{"id":590,"libraryId":5,"type":15,"typeLabel":16,"stem":591,"options":592,"answer":30,"analysis":33},933498,"下列场所中，需要设置排烟设施的有（ ）。",[593,595,597,599],{"key":20,"text":594,"correct":22},"建筑面积为3000m2的酚醛泡沫塑料加工厂房",{"key":24,"text":596,"correct":22},"占地面积为500m2的面粉仓库",{"key":27,"text":598,"correct":22},"建筑高度为28m的空分机房内长度为25m的内走道",{"key":30,"text":600,"correct":32},"占地面积为1500m2的棉花仓库",{"id":602,"libraryId":5,"type":15,"typeLabel":16,"stem":603,"options":604,"answer":27,"analysis":33},933499,"有关自然排烟和自然通风的说法，正确的是（ ）。",[605,607,609,611],{"key":20,"text":606,"correct":22},"自然排烟不属于排烟方式",{"key":24,"text":608,"correct":22},"自然通风不属于防烟方式",{"key":27,"text":610,"correct":32},"自然排烟是简单、不消耗动力的排烟方式",{"key":30,"text":612,"correct":22},"自然通风不易受外部条件的影响，是一种理想的排烟方式",{"id":614,"libraryId":5,"type":15,"typeLabel":16,"stem":615,"options":616,"answer":20,"analysis":33},933500,"某公共建筑，建筑高度为34m，防烟楼梯间采用自然通风，则应在防烟楼梯间的最高部位设置面积不应小于（ ）m2的开口。",[617,618,619,620],{"key":20,"text":171,"correct":32},{"key":24,"text":173,"correct":22},{"key":27,"text":232,"correct":22},{"key":30,"text":175,"correct":22},{"id":622,"libraryId":5,"type":15,"typeLabel":16,"stem":623,"options":624,"answer":24,"analysis":33},933501,"下列建筑可采用自然通风方式防烟的是（ ）。",[625,627,629,631],{"key":20,"text":626,"correct":22},"建筑高度为62m的公共建筑",{"key":24,"text":628,"correct":32},"建筑高度为99m的住宅建筑",{"key":27,"text":630,"correct":22},"建筑高度为58m的仓库",{"key":30,"text":632,"correct":22},"建筑高度为60m的厂房",{"id":634,"libraryId":5,"type":15,"typeLabel":16,"stem":635,"options":636,"answer":24,"analysis":33},933502,"防烟系统是防止烟气进入前室、楼梯间等空间的系统，当前室或合用前室满足一定的条件时，楼梯间可不设置防烟系统。下列建筑的楼梯间内可不设置防烟系统的是（ ）。",[637,639,641,643],{"key":20,"text":638,"correct":22},"建筑高度为120m的住宅，防烟楼梯间前室具有不同朝向且满足自然排烟口面积要求的可开启外窗",{"key":24,"text":640,"correct":32},"建筑高度为50m的宾馆，防烟楼梯间前室采用敞开的凹廊",{"key":27,"text":642,"correct":22},"建筑高度为90m的住宅，防烟楼梯间前室不具备自然通风条件",{"key":30,"text":644,"correct":22},"建筑高度为58m的综合楼，防烟楼梯间前室采用敞开的阳台",{"id":646,"libraryId":5,"type":15,"typeLabel":16,"stem":647,"options":648,"answer":30,"analysis":33},933503,"某办公楼设置的机械排烟管道采用不锈钢材料制作，管道的设计风速不应大于（ ）m\u002Fs，排烟口的风速不宜大于（ ）m\u002Fs。",[649,651,653,655],{"key":20,"text":650,"correct":22},"15，10",{"key":24,"text":652,"correct":22},"20，7",{"key":27,"text":654,"correct":22},"10，7",{"key":30,"text":656,"correct":32},"20，10",[658,661,664,667,670,673],{"id":15,"name":659,"category":7,"favorite":660},"领导干部任职前廉政法规知识测试题",92,{"id":662,"name":663,"category":7,"favorite":15},595,"建筑结构与设备",{"id":665,"name":666,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":668,"name":669,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":671,"name":672,"category":7,"favorite":8},534,"BIM工程师",{"id":674,"name":672,"category":7,"favorite":8},535]