[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-35":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":597},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,35,50,2960,[13,34,46,58,70,82,94,106,118,128,140,148,157,169,181,193,205,217,229,241,253,265,277,289,301,313,321,333,345,357,369,381,389,401,413,425,437,449,461,473,484,496,508,520,532,544,556,568,576,588],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},933404,1,"单选题","根据《火灾自动报警系统设计规范》（GB50116-2013）的要求，剩余电流式电气火灾监控探测器应设置在（ ）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","低压配电系统的末端",false,{"key":24,"text":25,"correct":22},"B","高压配电系统的首端",{"key":27,"text":28,"correct":29},"C","低压配电系统的首端",true,{"key":31,"text":32,"correct":22},"D","高压配电系统的末端","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},933405,"下列关于剩余电流式电气火灾监控探测器设置的做法，正确的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"IT系统配电线路上采用剩余电流式电气火灾监控探测器",{"key":24,"text":41,"correct":22},"消防配电线路的最末一级配电箱处设置剩余电流式电气火灾监控探测器",{"key":27,"text":43,"correct":22},"消防配电线路中采用剩余电流式电气火灾监控探测器",{"key":31,"text":45,"correct":29},"剩余电流式电气火灾监控探测器的探测器报警值设置为380mA",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},933406,"下列消防设备中，无需在消防控制室火灾报警控制器（联动型）或消防联动控制器的手动控制盘设置直接手动控制功能的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"采用分区给水的转输泵",{"key":24,"text":53,"correct":29},"稳压泵",{"key":27,"text":55,"correct":22},"消防水泵",{"key":31,"text":57,"correct":22},"排烟风机",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},933407,"下列关于消防控制室的说法中，不正确的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"消防控制室内严禁穿过与消防设施无关的电气线路及管路",{"key":24,"text":65,"correct":29},"消防控制室内不应设置其他弱电系统",{"key":27,"text":67,"correct":22},"疏散门应直通室外或安全出口",{"key":31,"text":69,"correct":22},"单独建造的消防控制室的耐火等级不应低于二级",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},933408,"在火灾报警后经逻辑确认，消防联动控制器应在（ ）s内按设定的控制逻辑准确发出联动控制信号给相应的消防设备。",[74,76,78,80],{"key":20,"text":75,"correct":22},"10",{"key":24,"text":77,"correct":22},"5",{"key":27,"text":79,"correct":22},"2",{"key":31,"text":81,"correct":29},"3",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},933409,"下列有关疏散通道上设置的防火卷帘的联动控制设计的做法，正确的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"报警区域内任两只独立的感烟火灾探测器的报警信号联动控制防火卷帘下降至距楼板面1．8m处；专门用于联动防火卷帘的感温火灾探测器的报警信号联动控制防火卷帘下降到楼板面",{"key":24,"text":89,"correct":29},"防火分区内专门用于联动防火卷帘的感烟火灾探测器的报警信号联动控制防火卷帘下降至距楼板面1．8m处；专门用于联动防火卷帘的感温火灾探测器的报警信号联动控制防火卷帘下降到楼板面",{"key":27,"text":91,"correct":22},"防火分区内任两只独立的感温火灾探测器的报警信号联动控制防火卷帘下降至距楼板面1．8m处；专门用于联动防火卷帘的感温火灾探测器的报警信号联动控制防火卷帘下降到楼板面",{"key":31,"text":93,"correct":22},"报警区域内专门用于联动防火卷帘的感烟火灾探测器的报警信号联动控制防火卷帘下降至距楼板面1．8m处；专门用于联动防火卷帘的感温火灾探测器的报警信号联动控制防火卷帘下降到楼板面",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},933410,"某公共建筑6层，设置集中控制火灾自动报警系统，下列关于该建筑火灾警报和消防应急广播系统的联动控制设计的说法中，不正确的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"火灾确认后，消防联动控制器应控制建筑内所有火灾声光警报器动作",{"key":24,"text":101,"correct":22},"火灾确认后，消防联动控制器应控制消防应急广播向全楼进行广播",{"key":27,"text":103,"correct":22},"消防应急广播的单次语音播放时间宜为10s～30s，可采取1次火灾声警报器播放、2次消防应急广播播放的交替工作方式循环播放",{"key":31,"text":105,"correct":29},"火灾声警报器单次发出火灾警报时间宜为10s～20s，可采取1次火灾声警报器播放、1次消防应急广播播放的交替工作方式循环播放",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},933411,"某场所室内的火灾自动报警系统供电线路采用明敷设的方式，下列关于对供电线路进行保护的做法，错误的是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"采用金属管保护",{"key":24,"text":113,"correct":29},"采用塑料封闭式线槽保护",{"key":27,"text":115,"correct":22},"采用可挠电气导管保护",{"key":31,"text":117,"correct":22},"采用金属封闭线槽保护",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":31,"analysis":33},933412,"某办公楼，地上6层，层高4m，办公室沿疏散走道两边“一”字布置，每个办公室建筑面积为200m2，室内为不设吊顶的平屋面，当每个办公室作为一个探测区域设置探测器时，每个办公室应至少设置（ ）个点型感烟火灾探测器。",[122,124,125,126],{"key":20,"text":123,"correct":22},"1",{"key":24,"text":79,"correct":22},{"key":27,"text":81,"correct":22},{"key":31,"text":127,"correct":29},"4",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":31,"analysis":33},933413,"某电子计算机房设置七氟丙烷气体灭火系统保护，当系统收到同一防护区内第二个联动触发信号后应发出联动控制信号，下列不属于联动控制信号内容的是（ ）。",[132,134,136,138],{"key":20,"text":133,"correct":22},"关闭防护区域的送风机及送风阀门",{"key":24,"text":135,"correct":22},"停止通风和空气调节系统",{"key":27,"text":137,"correct":22},"关闭设置在该防护区域的电动防火阀",{"key":31,"text":139,"correct":29},"启动防护区内的火灾声光警报器",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":24,"analysis":33},933414,"某建筑设置了火灾自动报警系统，其中一个报警回路穿过了三个防火分区，A防火分区连接3个探测器，B防火分区连接4个探测器，C防火分区连接35个探测器，则该回路至少需要设置（ ）个总线短路隔离器。",[144,145,146,147],{"key":20,"text":81,"correct":22},{"key":24,"text":127,"correct":29},{"key":27,"text":77,"correct":22},{"key":31,"text":123,"correct":22},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":24,"analysis":33},933415,"某工厂烘干车间，其内部设置“一”字形内疏散走道，宽2．2m，长度为45m，该走道顶棚上至少应设置（ ）只点型感温火灾探测器。",[152,153,154,155],{"key":20,"text":127,"correct":22},{"key":24,"text":77,"correct":29},{"key":27,"text":81,"correct":22},{"key":31,"text":156,"correct":22},"6",{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":31,"analysis":33},933416,"集中报警控制系统和控制中心报警系统的区域火灾报警控制器在满足一定的条件时，可以设置在无人值班的场所，下列不属于该条件内容的是（ ）。",[161,163,165,167],{"key":20,"text":162,"correct":22},"无人值班的场所只有值班人员可以进人",{"key":24,"text":164,"correct":22},"报警区域内没有需要手动控制的消防联动设备",{"key":27,"text":166,"correct":22},"区域火灾报警控制器上的所有信息均在集中火灾报警控制器上有显示",{"key":31,"text":168,"correct":29},"报警区域内没有安装火灾警报装置",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":31,"analysis":33},933417,"下列关于火灾探测器设置的说法中，不正确的是（ ）。",[173,175,177,179],{"key":20,"text":174,"correct":22},"火焰探测器应避免光源直接照射在探测器的探测窗口",{"key":24,"text":176,"correct":22},"线型光束感烟火灾探测器至侧墙水平距离不应大于7m，且不应小于0．5m，探测器的发射器和接收器之间的距离不宜超过100m",{"key":27,"text":178,"correct":22},"设置在顶棚下方的线型感温火灾探测器，至顶棚的距离宜为0．1m",{"key":31,"text":180,"correct":29},"线型光束感烟火灾探测器的光束轴线至顶棚的垂直距离宜为0．3m～1．0m，距地高度不宜超过15m",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":24,"analysis":33},933418,"某展览管采用格栅式吊顶进行装修，吊顶的镂空面积与吊顶的总面积之比为35％，下列关于感烟探测器安装位置的说法中，正确的是（ ）。",[185,187,189,191],{"key":20,"text":186,"correct":22},"应安装在吊顶下方",{"key":24,"text":188,"correct":29},"应安装在吊顶上方",{"key":27,"text":190,"correct":22},"应同时安装在吊顶上方和下方",{"key":31,"text":192,"correct":22},"安装在吊顶上方和下方均可",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":31,"analysis":33},933419,"根据《火灾自动报警系统设计规范》GB50116—2013的规定，火灾自动报警系统的下列部件中，安装高度与其他选项不一致的是（ ）。",[197,199,201,203],{"key":20,"text":198,"correct":22},"手动火灾报警按钮",{"key":24,"text":200,"correct":22},"火灾显示盘",{"key":27,"text":202,"correct":22},"消防专用电话插孔",{"key":31,"text":204,"correct":29},"电动防火门手动控制按钮",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":24,"analysis":33},933420,"根据《火灾自动报警系统设计规范》GB50116—2013的规定，下列线路应采用耐火铜芯电线电缆的是（ ）。",[209,211,213,215],{"key":20,"text":210,"correct":22},"报警总线",{"key":24,"text":212,"correct":29},"消防联动控制线路",{"key":27,"text":214,"correct":22},"消防应急广播线路",{"key":31,"text":216,"correct":22},"消防专用电话线路",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":27,"analysis":33},933421,"下列关于水幕系统的联动控制设计的说法错误的是（ ）。",[221,223,225,227],{"key":20,"text":222,"correct":22},"用于防火卷帘保护的水幕系统，应由防火卷帘下落到楼板面的动作信号与本报警区域内任一火灾探测器的报警信号作为水幕阀组启动的联动触发信号",{"key":24,"text":224,"correct":22},"用于防火卷帘保护的水幕系统，应由防火卷帘下落到楼板面的动作信号与本报警区域内任一手动火灾报警按钮的报警信号作为水幕阀组启动的联动触发信号",{"key":27,"text":226,"correct":29},"用于防火分隔的水幕系统，应由该报警区域内两只独立的感烟火灾探测器的火灾报警信号作为水幕阀组启动的联动触发信号",{"key":31,"text":228,"correct":22},"压力开关、探制阀组和消防泵的启停信号应反馈至消防联动控制器",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":20,"analysis":33},933422,"某建筑内设有湿式消火栓系统、自动喷水灭火系统和火灾自动报警系统等，下列关于湿式消火栓系统联动控制的说法，不正确是（ ）。",[233,235,237,239],{"key":20,"text":234,"correct":29},"高位消防水箱的水位信号作为触发信号直接启泵",{"key":24,"text":236,"correct":22},"消火栓按钮的动作信号作为启动消火栓泵的联动触发信号",{"key":27,"text":238,"correct":22},"出水干管上的低压压力开关的动作信号作为触发信号直接启泵",{"key":31,"text":240,"correct":22},"出水干管上的低压压力开关的动作信号直接启泵不受消防联动控制器处于自动或手动状态影响",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":24,"analysis":33},933423,"下列关于防烟排烟系统联动控制设计的说法，错误的是（ ）。",[245,247,249,251],{"key":20,"text":246,"correct":22},"应由加压送风口所在防火分区内的两只独立的火灾探测器或一只火灾探测器与一只手动火灾报警按钮的报警信号，作为送风口开启和加压送风机启动的联动触发信号",{"key":24,"text":248,"correct":29},"应由同一防烟分区内且位于电动挡烟垂壁附近的两只独立的感温火灾探测器的报警信号，作为电动挡烟垂壁降落的联动触发信号",{"key":27,"text":250,"correct":22},"应由同一防烟分区内的两只独立的火灾探测器的报警信号，作为排烟口、排烟窗或排烟阀开启的联动触发信号，并应由消防联动控制器联动控制排烟口、排烟窗或排烟阀的开启，同时停止该防烟分区的空气调节系统",{"key":31,"text":252,"correct":22},"送风口和排烟口的动作信号应反馈至消防联动控制器",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":27,"analysis":33},933424,"某建筑面积为2000m2的展厅，层高为7m，设置了格栅吊顶，吊顶距离楼地面6m。镂空面积与吊顶的总面积之比为10％。该展厅内感烟火灾探测器应设置的位置是（ ）。",[257,259,261,263],{"key":20,"text":258,"correct":22},"吊顶上方",{"key":24,"text":260,"correct":22},"吊顶上方和下方",{"key":27,"text":262,"correct":29},"吊顶下方",{"key":31,"text":264,"correct":22},"根据实际试验结果确定",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":24,"analysis":33},933425,"火灾探测器根据其（ ）分类，分为点型火灾探测器和线型火灾探测器。",[269,271,273,275],{"key":20,"text":270,"correct":22},"探测火灾特征参数",{"key":24,"text":272,"correct":29},"监视范围不同",{"key":27,"text":274,"correct":22},"是否具有可拆卸性",{"key":31,"text":276,"correct":22},"是否具有复位功能",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":31,"analysis":33},933426,"手动火灾报警按钮是火灾自动报警系统中不可缺少的一种手动触发器件，它通过手动操作报警按钮向火灾报警控制器发出火灾报警信号。下列有关手动火灾报警按钮设置要求的说法中，错误的是（ ）。",[281,283,285,287],{"key":20,"text":282,"correct":22},"每个防火分区应至少设置一只手动火灾报警按钮",{"key":24,"text":284,"correct":22},"从一个防火分区内的任何位置到最邻近的手动火灾报警按钮的步行距离不应大于30m",{"key":27,"text":286,"correct":22},"手动火灾报警按钮采用擘挂方式安装时，底边距地面高度宜为1.3m～1.5m",{"key":31,"text":288,"correct":29},"列车上设置的手动火灾报警按钮，应设置在每节车厢的中间部位",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":20,"analysis":33},933427,"下列关于火灾自动报警系统消防联动控制的说法中，错误的是（ ）。",[293,295,297,299],{"key":20,"text":294,"correct":29},"消防联动控制器的电压控制输出应采用直流36V",{"key":24,"text":296,"correct":22},"消防水泵的控制设备，除应采用联动控制方式外，还应在消防控制室设置手动直接控制装置",{"key":27,"text":298,"correct":22},"防烟和排烟风机的控制设备，除应采用联动控制方式外，还应在消防控制室设置手动直接控制装置",{"key":31,"text":300,"correct":22},"启动电流较大的消防设备宜分时启动",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":27,"analysis":33},933428,"由消防控制室接地板引至各消防电子设备的专用接地线应选用铜芯绝缘导线，其线芯横截面面积不应小于（ ）平方毫米；消防控制室接地板与建筑接地体之间，应采用线芯截面面积不小于（ ）平方毫米的铜芯绝缘导线连接。",[305,307,309,311],{"key":20,"text":306,"correct":22},"4，20",{"key":24,"text":308,"correct":22},"5，20",{"key":27,"text":310,"correct":29},"4，25",{"key":31,"text":312,"correct":22},"5，25",{"id":314,"libraryId":5,"type":15,"typeLabel":16,"stem":315,"options":316,"answer":27,"analysis":33},933429,"某电缆隧道内设置了火灾自动报警系统，该电缆隧道共有8个封闭长度区间，每个封闭长度区间长100m，则该电缆隧道至少应划分（ ）个报警区域。",[317,318,319,320],{"key":20,"text":123,"correct":22},{"key":24,"text":79,"correct":22},{"key":27,"text":81,"correct":29},{"key":31,"text":127,"correct":22},{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":27,"analysis":33},933430,"下列关于可燃气体探测器的说法，正确的是（ ）。",[325,327,329,331],{"key":20,"text":326,"correct":22},"可燃气体探测器应接入火灾自动报警系统的探测回路",{"key":24,"text":328,"correct":22},"线型可燃气体探测器的保护区域长度为80m",{"key":27,"text":330,"correct":29},"可燃气体报警控制器将报警信号传输至消防控制室的图形显示装置或集中火灾报警控制器，但其显示应与火灾报警信息有区别",{"key":31,"text":332,"correct":22},"石化行业涉及过程控制的可燃气体探测器，不可接入DCS等生产控制系统，要直接将其报警信号接入消防控制室",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":20,"analysis":33},933431,"下列关于火灾自动报警系统布线设计要求的说法中，不正确的是（）。",[337,339,341,343],{"key":20,"text":338,"correct":29},"采用穿管水平敷设时，不同防火分区的线路均不应穿入同一根管内",{"key":24,"text":340,"correct":22},"不同电压等级的线缆不应穿入同一根保护管内，当合用同一线槽时，线槽内应有隔板分隔",{"key":27,"text":342,"correct":22},"火灾探测器的传输线路，宜选择不同颜色的绝缘导线或电缆",{"key":31,"text":344,"correct":22},"供电线路和传输线路设置在室外时，应埋地敷设",{"id":346,"libraryId":5,"type":15,"typeLabel":16,"stem":347,"options":348,"answer":31,"analysis":33},933432,"下列关于地铁列车上设置火灾自动报警系统的说法，不正确的是（）。",[349,351,353,355],{"key":20,"text":350,"correct":22},"系统应能通过无线网络将列车上发生火灾部位的信息传输给消防控制器",{"key":24,"text":352,"correct":22},"列车的报警区域应按车厢划分，每节车厢应划分为一个报警区域",{"key":27,"text":354,"correct":22},"手动火灾报警按钮应设置在每节车厢的出入口和中间部位",{"key":31,"text":356,"correct":29},"车厢内宜设置点型感温火灾探测器",{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":20,"analysis":33},933433,"火灾自动报警系统的布线包括供电线路、信号传输线路和控制线路，这些线路是火灾自动报警系统完成报警和控制功能的重要组成部分，下列关于布线设计要求的说法中，不正确的是（）。",[361,363,365,367],{"key":20,"text":362,"correct":29},"火灾自动报警系统的供电线路应采用阻燃耐火电线电缆",{"key":24,"text":364,"correct":22},"报警总线应采用阻燃或阻燃耐火电线电缆",{"key":27,"text":366,"correct":22},"消防联动控制线路应采用耐火铜芯电线电缆",{"key":31,"text":368,"correct":22},"消防应急广播应采用阻燃或阻燃耐火电线电缆",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":27,"analysis":33},933434,"根据《火灾自动报警系统设计规范》（GB 50116-2013）规定，在宽度小于3m的内走道顶棚上设置火灾探测器，下列有关火灾探测器安装间距要求的说法，正确的是（）。",[373,375,377,379],{"key":20,"text":374,"correct":22},"点型探测器周围1m范围内，不应有遮挡物",{"key":24,"text":376,"correct":22},"点型探测器至墙壁、梁边的水平距离，不应小于1m",{"key":27,"text":378,"correct":29},"感温火灾探测器的安装间距不应超过10m",{"key":31,"text":380,"correct":22},"点型探测器宜接近送风口安装",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":31,"analysis":33},933435,"某建筑高度为28m的工业建筑，层高为4m，层数为7层，每层建筑面积为1200m2，其“一”字型内走道的宽度为2．8m，长度为31m，该走道顶棚上至少应设置（）只点型感温火灾探测器。",[385,386,387,388],{"key":20,"text":79,"correct":22},{"key":24,"text":81,"correct":22},{"key":27,"text":77,"correct":22},{"key":31,"text":127,"correct":29},{"id":390,"libraryId":5,"type":15,"typeLabel":16,"stem":391,"options":392,"answer":31,"analysis":33},933436,"根据《火灾自动报警系统设计规范》GB50116—2013的规定，下列关于消防控制室内设备的设置要求说法中，正确的是（）。",[393,395,397,399],{"key":20,"text":394,"correct":22},"设备面盘的排列长度大于3m时，其两端应设置宽度不小于1m的通道",{"key":24,"text":396,"correct":22},"设备面盘前的操作距离，单列布置时不应小于1m",{"key":27,"text":398,"correct":22},"设备面盘的排列长度大于4m时，设备面盘后的维修距离不宜小于1m",{"key":31,"text":400,"correct":29},"设备面盘前的操作距离，双列布置时不应小于2m",{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":31,"analysis":33},933437,"火灾探测器根据其探测火灾特征参数的不同，可以分为感烟、感温、感光、气体、复合五种基本类型，其中感光火灾探测器又被称为（ ）。",[405,407,409,411],{"key":20,"text":406,"correct":22},"缆式线性探测器",{"key":24,"text":408,"correct":22},"红外火灾探测器",{"key":27,"text":410,"correct":22},"点型火灾探测器",{"key":31,"text":412,"correct":29},"火焰探测器",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":20,"analysis":33},933438,"（ ）是指响应悬浮在大气中的燃烧和或热解产生的固体或液体微粒的探测器。",[417,419,421,423],{"key":20,"text":418,"correct":29},"感烟火灾探测器",{"key":24,"text":420,"correct":22},"感温火灾探测器",{"key":27,"text":422,"correct":22},"气体火灾探测器",{"key":31,"text":424,"correct":22},"感光火灾探测器",{"id":426,"libraryId":5,"type":15,"typeLabel":16,"stem":427,"options":428,"answer":31,"analysis":33},933439,"某场所设置两个消防控制室，在选则火灾自动报警系统形式的时候，应采用（ ）。",[429,431,433,435],{"key":20,"text":430,"correct":22},"区域报警系统",{"key":24,"text":432,"correct":22},"消防联动控制系统",{"key":27,"text":434,"correct":22},"集中报警系统",{"key":31,"text":436,"correct":29},"控制中心报警系统",{"id":438,"libraryId":5,"type":15,"typeLabel":16,"stem":439,"options":440,"answer":24,"analysis":33},933440,"火灾探测报警系统由火灾报警控制器、触发器件和火灾警报装置等组成，其中触发器件指的是（ ）。",[441,443,445,447],{"key":20,"text":442,"correct":22},"火灾声警报器",{"key":24,"text":444,"correct":29},"火灾探测器",{"key":27,"text":446,"correct":22},"消防电话",{"key":31,"text":448,"correct":22},"消防应急广播",{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":24,"analysis":33},933441,"下列关于消防电话的说法，错误的是（ ）。",[453,455,457,459],{"key":20,"text":454,"correct":22},"消防电话的总机设在消防控制室",{"key":24,"text":456,"correct":29},"消防电话是用于消防控制室与外部联系的报警电话",{"key":27,"text":458,"correct":22},"消防电话插孔安装在建筑物各处，插上电话手柄就可以和消防电话总机通信",{"key":31,"text":460,"correct":22},"消防电话一般采用集中式对讲电话",{"id":462,"libraryId":5,"type":15,"typeLabel":16,"stem":463,"options":464,"answer":27,"analysis":33},933442,"下列选项中，不宜安装点型感烟火灾探测器的场所是（ ）。",[465,467,469,471],{"key":20,"text":466,"correct":22},"计算机房",{"key":24,"text":468,"correct":22},"书库",{"key":27,"text":470,"correct":29},"烘干车间",{"key":31,"text":472,"correct":22},"通信机房",{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":27,"analysis":33},933443,"根据《火灾自动报警系统设计规范》（GB50116—2013）的规定，火灾报警控制器和消防联动控制器安装在墙上时，其正面操作距离不应小于（ ）m。",[477,479,481,483],{"key":20,"text":478,"correct":22},"1．0",{"key":24,"text":480,"correct":22},"1．1",{"key":27,"text":482,"correct":29},"1．2",{"key":31,"text":79,"correct":22},{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":27,"analysis":33},933444,"某建筑设置了管路采样式吸气感烟火灾探测器，下列关于该装置设置的说法中，错误的是（ ）。",[488,490,492,494],{"key":20,"text":489,"correct":22},"一个探测单元的采样管总长不宜超过200m",{"key":24,"text":491,"correct":22},"同一根采样管不应穿越防火分区",{"key":27,"text":493,"correct":29},"单管采样孔总数不宜超过100个",{"key":31,"text":495,"correct":22},"非高灵敏型探测器的采样管网安装高度不应超过16m",{"id":497,"libraryId":5,"type":15,"typeLabel":16,"stem":498,"options":499,"answer":24,"analysis":33},933445,"下列关于火灾自动报警系统区域显示器设置的说法，错误的是（ ）。",[500,502,504,506],{"key":20,"text":501,"correct":22},"每个报警区域宜设置一台区域显示器",{"key":24,"text":503,"correct":29},"当一个报警区域包括多个楼层时，宜在其中一个楼层设置一台可以显示多个楼层的区域显示器",{"key":27,"text":505,"correct":22},"区域显示器应设置在出入口等明显和便于操作的部位",{"key":31,"text":507,"correct":22},"当区域显示器采用壁挂方式安装时，其底边距地高度宜为1．3m～1．5m",{"id":509,"libraryId":5,"type":15,"typeLabel":16,"stem":510,"options":511,"answer":31,"analysis":33},933446,"下列关于防火门监控器设置的说法，正确的是（ ）。",[512,514,516,518],{"key":20,"text":513,"correct":22},"防火门监控器应设置在防火门附近",{"key":24,"text":515,"correct":22},"电动开门器的手动控制按钮应设置在防火门外侧墙面上，距门不宜超过0．5m",{"key":27,"text":517,"correct":22},"电动开门器的手动控制按钮底边距地面高度宜为1．3m～1．5m",{"key":31,"text":519,"correct":29},"防火门监控器的设置应符合火灾报警控制器的安装设置要求",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":27,"analysis":33},933447,"某建筑设置湿式自动喷水灭火系统保护，下列关于该系统联动控制的做法，正确的是（ ）。",[524,526,528,530],{"key":20,"text":525,"correct":22},"同一报警区域内两只独立的感温火灾探测器报警信号，作为湿式报警阀组开启的联动触发信号，由消防联动控制器控制湿式报警阀组的开启",{"key":24,"text":527,"correct":22},"同一报警区域内两只独立的感烟火灾探测器报警信号，作为湿式报警阀组开启的联动触发信号，由消防联动控制器控制湿式报警阀组的开启",{"key":27,"text":529,"correct":29},"湿式报警阀压力开关的动作信号作为触发信号，直接控制启动喷淋消防泵，联动控制不应受消防联动控制器处于自动或手动状态影响",{"key":31,"text":531,"correct":22},"同一报警区域内一只感烟火灾探测器与一只手动火灾报警按钮的报警信号，作为湿式报警阀组开启的联动触发信号，由消防联动控制器控制湿式报警阀组的开启",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":27,"analysis":33},933448,"下列关于自动控制的水幕系统联动控制设计的说法中，正确的是（ ）。",[536,538,540,542],{"key":20,"text":537,"correct":22},"用于防火卷帘保护时，应由防火卷帘下落到1．8m的动作信号与本防火分区内任一火灾探测器的报警信号作为水幕阀组启动的联动触发信号，并应由消防联动控制器联动控制水幕系统相关控制阀组的启动",{"key":24,"text":539,"correct":22},"用于防火卷帘保护时，应由防火卷帘下落到楼板面的动作信号与本防火分区内任一火灾探测器的报警信号作为水幕阀组启动的联动触发信号，并应由消防联动控制器联动控制水幕系统相关控制阀组的启动",{"key":27,"text":541,"correct":29},"当水幕系统仅用于防火分隔时，应由该报警区域内两只独立的感温火灾探测器的火灾报警信号作为水幕阀组启动的联动触发信号，并应由消防联动控制器联动控制水幕系统相关控制阀组的启动",{"key":31,"text":543,"correct":22},"当水幕系统仅用于防火分隔时，应由该报警区域内两只独立的感烟火灾探测器的火灾报警信号作为水幕阀组启动的联动触发信号，并应由消防联动控制器联动控制水幕系统相关控制阀组的启动",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":27,"analysis":33},933449,"下列有关雨淋系统联动控制的做法，正确的是（ ）。",[548,550,552,554],{"key":20,"text":549,"correct":22},"由同一探测区域内两只独立及以上的感温火灾探测器的报警信号，作为雨淋阀组开启的联动触发信号",{"key":24,"text":551,"correct":22},"由同一探测区域内一只感烟火灾探测器与一只感温火灾探测器的报警信号，作为雨淋阀组开启的联动触发信号",{"key":27,"text":553,"correct":29},"由同一报警区域内两只及以上独立的感温火灾探测器的报警信号，作为雨淋阀组开启的联动触发信号",{"key":31,"text":555,"correct":22},"由同一报警区域内一只感烟火灾探测器与一只感温火灾探测器的报警信号，作为雨淋阀组开启的联动触发信号",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":27,"analysis":33},933450,"电气火灾监控探测系统中具有探测线路故障电弧功能的电气火灾监控探测器，其保护线路的长度不宜大于（ ）m。",[560,562,564,566],{"key":20,"text":561,"correct":22},"50",{"key":24,"text":563,"correct":22},"60",{"key":27,"text":565,"correct":29},"100",{"key":31,"text":567,"correct":22},"120",{"id":569,"libraryId":5,"type":15,"typeLabel":16,"stem":570,"options":571,"answer":24,"analysis":33},933451,"当确认火灾后，由发生火灾的报警区域开始，消防应急照明和疏散指示系统全部投入应急状态的启动时间不应大于（ ）s。",[572,573,574,575],{"key":20,"text":79,"correct":22},{"key":24,"text":77,"correct":29},{"key":27,"text":127,"correct":22},{"key":31,"text":75,"correct":22},{"id":577,"libraryId":5,"type":15,"typeLabel":16,"stem":578,"options":579,"answer":31,"analysis":33},933452,"某民用建筑内部设置有消防应急广播，下列关于该装置设置的做法，错误的是（ ）。",[580,582,584,586],{"key":20,"text":581,"correct":22},"在该建筑环境噪声大于60dB的场所设置的扬声器，其播放范围内最远点的播放声压级高于背景噪声15dB",{"key":24,"text":583,"correct":22},"扬声器设置在走道和大厅等公共场所",{"key":27,"text":585,"correct":22},"走道末端距最近的扬声器距离为10m",{"key":31,"text":587,"correct":29},"壁挂扬声器的底边距地面高度为2．2m",{"id":589,"libraryId":5,"type":15,"typeLabel":16,"stem":590,"options":591,"answer":31,"analysis":33},933453,"下列部件不属于火灾探测报警系统中触发器件的是（ ）。",[592,594,595,596],{"key":20,"text":593,"correct":22},"感烟探测器",{"key":24,"text":420,"correct":22},{"key":27,"text":198,"correct":22},{"key":31,"text":200,"correct":29},[598,601,604,607,610,613],{"id":15,"name":599,"category":7,"favorite":600},"领导干部任职前廉政法规知识测试题",92,{"id":602,"name":603,"category":7,"favorite":15},595,"建筑结构与设备",{"id":605,"name":606,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":608,"name":609,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":611,"name":612,"category":7,"favorite":8},534,"BIM工程师",{"id":614,"name":612,"category":7,"favorite":8},535]