[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-34":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":641},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,34,50,2960,[13,38,53,68,83,97,112,127,142,154,169,184,198,213,228,242,251,262,274,286,298,310,322,334,346,358,370,382,394,406,418,430,442,454,466,476,488,500,511,520,531,542,554,563,575,587,598,608,620,629],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},933354,2,"多选题","下列探测器属于感烟火灾探测器的是（ ）。",[19,23,26,30,33],{"key":20,"text":21,"correct":22},"A","离子感烟火灾探测器",true,{"key":24,"text":25,"correct":22},"B","光电感烟火灾探测器",{"key":27,"text":28,"correct":29},"C","火焰火灾探测器",false,{"key":31,"text":32,"correct":29},"D","红外紫外复合火灾探测器",{"key":34,"text":35,"correct":22},"E","红外光束感烟火灾探测器","ABE","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},933355,"根据《火灾自动报警系统设计规范》（GB50116—2013）的规定，火灾自动报警系统的形式可以分为（ ）。",[42,44,46,48,50],{"key":20,"text":43,"correct":29},"可燃气体探测报警系统",{"key":24,"text":45,"correct":22},"区域报警系统",{"key":27,"text":47,"correct":22},"集中报警系统",{"key":31,"text":49,"correct":22},"控制中心报警系统",{"key":34,"text":51,"correct":29},"消防联动控制系统","BCD",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},933356,"某建筑内设有火灾自动报警系统，在系统划分探测区域时，下列场所或部位应单独划分的有（ ）。",[57,59,61,63,65],{"key":20,"text":58,"correct":22},"防烟楼梯间",{"key":24,"text":60,"correct":22},"通信管道井",{"key":27,"text":62,"correct":29},"消防电梯",{"key":31,"text":64,"correct":22},"电气管道井",{"key":34,"text":66,"correct":22},"建筑夹层","ABDE",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":82,"analysis":37},933357,"根据《火灾自动报警系统设计规范》（GB50116—2013）的规定，（ ）应设置可直接报警的外线电话。",[72,74,76,78,80],{"key":20,"text":73,"correct":29},"消防水泵房",{"key":24,"text":75,"correct":22},"企业消防站",{"key":27,"text":77,"correct":29},"配变电室",{"key":31,"text":79,"correct":22},"消防值班室",{"key":34,"text":81,"correct":29},"发电机房","BD",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":67,"analysis":37},933358,"消防控制室图形显示装置与（ ）之间，应采用专用线路连接。",[87,89,91,93,95],{"key":20,"text":88,"correct":22},"火灾报警控制器",{"key":24,"text":90,"correct":22},"可燃气体报警控制器",{"key":27,"text":92,"correct":29},"火灾声光警报器",{"key":31,"text":94,"correct":22},"电气火灾监控器",{"key":34,"text":96,"correct":22},"消防联动控制器",{"id":98,"libraryId":5,"type":15,"typeLabel":16,"stem":99,"options":100,"answer":111,"analysis":37},933359,"下列有关消防控制室的说法中，正确的有（ ）。",[101,103,105,107,109],{"key":20,"text":102,"correct":22},"单独建造的消防控制室，其耐火等级不应低于二级",{"key":24,"text":104,"correct":22},"附设在建筑内的消防控制室，宜设置在建筑内首层或地下一层",{"key":27,"text":106,"correct":22},"消防控制室的疏散门应直通室外或安全出口",{"key":31,"text":108,"correct":22},"消防控制室不应设置在电磁场干扰较强的房间附近",{"key":34,"text":110,"correct":29},"消防控制室内可以穿过与消防设施无关的电气线路及管路，但应做好防火分隔措施","ABCD",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":126,"analysis":37},933360,"某建筑高度为68m的综合楼设有裙房，裙房地上3层，净空高度为6．2m，每层建筑面积为6800m2，与主体建筑之间设防火墙分隔，一到二层为商场，三层为美食城，裙房吊顶采用镂空设计，镂空面积为吊顶的总面积之比为35％，设有自动喷水灭火系统、防排烟系统、火灾自动报警系统保护，每个防火分区划分为一个报警区域。下列关于商场的设计中，符合规定的是（ ）。",[116,118,120,122,124],{"key":20,"text":117,"correct":22},"每层划分为2个报警区域",{"key":24,"text":119,"correct":29},"点型感烟火灾探测器应设在吊顶下方",{"key":27,"text":121,"correct":22},"每层划分4个防烟分区",{"key":31,"text":123,"correct":29},"可以采用类型为B型点型感温火灾探测器",{"key":34,"text":125,"correct":29},"美食城走道内设置的点型感烟火灾探测器距墙水平距离为0．3m","AC",{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":141,"analysis":37},933361,"火灾自动报警系统相关联动控制设计要求中，正确的是（ ）。",[131,133,135,137,139],{"key":20,"text":132,"correct":22},"消防联动控制器应具有切断火灾区域及相关区域的非消防电源的功能",{"key":24,"text":134,"correct":29},"当需要切断正常照明时， 宜在自动喷淋系统、 消火栓系统动作后方可切断",{"key":27,"text":136,"correct":22},"消防联动控制器应具有自动打开涉及疏散的电动栅杆等的功能",{"key":31,"text":138,"correct":22},"宜开启相关区域安全技术防范系统的摄像机监视火灾现场",{"key":34,"text":140,"correct":22},"消防联动控制器应具有打开疏散通道上由门禁系统控制的门和庭院电动大门的功能， 并应具有打开停车场出入口挡杆的功能。","ACDE",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":141,"analysis":37},933362,"火灾自动报警系统由（ ）组成。",[146,147,149,151,153],{"key":20,"text":51,"correct":22},{"key":24,"text":148,"correct":29},"自动灭火系统",{"key":27,"text":150,"correct":22},"电气火灾监控系统",{"key":31,"text":152,"correct":22},"火灾探测报警系统",{"key":34,"text":43,"correct":22},{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":168,"analysis":37},933363,"某5层宾馆，每层层高为4m，东西长60m，南北宽20m，建筑内“一”字形疏散走道沿东西方向布置，长度为60m，宽度为2m，走道两侧房间的进深均为9m，建筑设有室内消火栓系统、自动喷水灭火系统、火灾自动报警系统和防烟排烟系统等，宾馆每层划分为一个防火分区和一个报警区域。下列关于该宾馆的设计中，符合现行国家工程建设消防技术标准的是（ ）。",[158,160,162,164,166],{"key":20,"text":159,"correct":22},"宾馆内安装点型感烟火灾探测器",{"key":24,"text":161,"correct":22},"每层设置一台区域显示器",{"key":27,"text":163,"correct":29},"当确认宾馆三层发生火灾后，消防联动控制器控制该层所有的声光警报器动作",{"key":31,"text":165,"correct":29},"每层设置一只手动火灾报警按钮，位置在疏散走道的中间部位",{"key":34,"text":167,"correct":29},"设置在房间内的点型感烟火灾探测器距空调送风口的水平距离为1．0m","AB",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":183,"analysis":37},933364,"关于预作用自动喷水灭火系统联动控制，可以作为预作用阀组开启的联动触发信号有（ ）。",[173,175,177,179,181],{"key":20,"text":174,"correct":22},"同一报警区域内两只独立的感烟火灾探测器",{"key":24,"text":176,"correct":29},"同一报警区域内两只独立的感温火灾探测器",{"key":27,"text":178,"correct":29},"同一报警区域内一只感温火灾探测器和一只感烟探测器",{"key":31,"text":180,"correct":22},"同一报警区域内一只感烟火灾探测器与一只手动火灾报警按钮",{"key":34,"text":182,"correct":29},"同一报警区域内一只感温火灾探测器与一只手动火灾报警按钮","AD",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":126,"analysis":37},933365,"当自动控制的水幕系统用于保护防火卷帘时，不可作为水幕阀组联动触发信号的有（）。",[188,190,192,194,196],{"key":20,"text":189,"correct":22},"防火卷帘下落到距离地面1．8m处的信号与本报警区域内一只感烟火灾探测器的信号",{"key":24,"text":191,"correct":29},"防火卷帘下落到楼板面的动作信号与本报警区域内一只感温火灾探测器的信号",{"key":27,"text":193,"correct":22},"防火卷帘下落到距离地面1．8m处的信号与本报警区域内一只感温火灾探测器的信号",{"key":31,"text":195,"correct":29},"防火卷帘下落到楼板面的动作信号与本报警区域内一只感烟火灾探测器的信号",{"key":34,"text":197,"correct":29},"防火卷帘下落到楼板面的动作信号与本报警区域内一只手动火灾报警按钮的信号",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":212,"analysis":37},933366,"下列防烟、排烟系统的联动控制设计做法中，不正确的是（）。",[202,204,206,208,210],{"key":20,"text":203,"correct":29},"触发加压送风口所在防火分区内两只独立的火灾探测器，联动控制器控制控制加压送风口开启，启动送风机",{"key":24,"text":205,"correct":29},"触发同一防烟分区内两只独立的火灾探测器，联动控制器联动开启排烟口",{"key":27,"text":207,"correct":29},"触发加压送风口所在防火分区内一只独立的火灾探测器，按下同一防火分区内一只手动火灾报警按钮，联动控制器控制控制加压送风口开启，启动送风机",{"key":31,"text":209,"correct":22},"按下同一防烟分区内两只独立的手动火灾报警按钮，联动控制器联动开启排烟口",{"key":34,"text":211,"correct":22},"触发同一防火分区内任两只独立的火灾探测器，联动控制器联动开启排烟口","DE",{"id":214,"libraryId":5,"type":15,"typeLabel":16,"stem":215,"options":216,"answer":227,"analysis":37},933367,"在消火栓系统中，下列信号可以联动启动消防水泵的有（）。",[217,219,221,223,225],{"key":20,"text":218,"correct":22},"消火栓按钮的动作信号与该消火栓按钮所在报警区域内一只感温火灾探测器的报警信号",{"key":24,"text":220,"correct":29},"同一报警区域内一只感烟火灾探测器和一只手动报警按钮的报警信号",{"key":27,"text":222,"correct":22},"消火栓按钮的动作信号与该消火栓按钮所在报警区域内一只手动报警按钮的报警信号",{"key":31,"text":224,"correct":29},"同一报警区域内任一只火灾感温探测器和一只手动报警按钮的报警信号",{"key":34,"text":226,"correct":22},"消火栓按钮的动作信号与该消火栓按钮所在报警区域内一只感烟火灾探测器的报警信号","ACE",{"id":229,"libraryId":5,"type":230,"typeLabel":231,"stem":232,"options":233,"answer":24,"analysis":37},933368,1,"单选题","下列探测器的安装，符合现行国家消防技术标准要求的是（ ）。",[234,236,238,240],{"key":20,"text":235,"correct":29},"C类的点型感温火灾探测器安装高度为6m",{"key":24,"text":237,"correct":22},"A2类的点型感温火灾探测器安装高度为8m",{"key":27,"text":239,"correct":29},"B类的点型感温火灾探测器安装高度为7m",{"key":31,"text":241,"correct":29},"D类的点型感温火灾探测器安装高度为5m",{"id":243,"libraryId":5,"type":230,"typeLabel":231,"stem":244,"options":245,"answer":24,"analysis":37},933369,"下列部件属于集中报警系统，但不属于区域报警系统的是（ ）。",[246,248,249,250],{"key":20,"text":247,"correct":29},"火灾探测器",{"key":24,"text":96,"correct":22},{"key":27,"text":92,"correct":29},{"key":31,"text":88,"correct":29},{"id":252,"libraryId":5,"type":230,"typeLabel":231,"stem":253,"options":254,"answer":24,"analysis":37},933370,"火灾联动控制系统中，通过接收火灾报警控制器发出的火灾报警信息，按预设逻辑对建筑中设置的自动消防系统设施进行控制指的是（ ）。",[255,257,258,260],{"key":20,"text":256,"correct":29},"火灾报警装置",{"key":24,"text":96,"correct":22},{"key":27,"text":259,"correct":29},"消防控制室图形显示装置",{"key":31,"text":261,"correct":29},"消防电气控制装置",{"id":263,"libraryId":5,"type":230,"typeLabel":231,"stem":264,"options":265,"answer":31,"analysis":37},933371,"下列有关集中报警系统和控制中心报警系统的说法，错误的是（ ）。",[266,268,270,272],{"key":20,"text":267,"correct":29},"集中报警系统应设置消防控制室",{"key":24,"text":269,"correct":29},"控制中心报警系统应至少设置一个主消防控制室",{"key":27,"text":271,"correct":29},"集中报警系统中起到集中控制作用的消防设备，都应设置在消防控制室内",{"key":31,"text":273,"correct":22},"控制中心报警系统各分控制室内消防设备之间可以互相传输信息、相互控制",{"id":275,"libraryId":5,"type":230,"typeLabel":231,"stem":276,"options":277,"answer":24,"analysis":37},933372,"下列关于火灾自动报警系统探测区域划分的说法错误的是（ ）。",[278,280,282,284],{"key":20,"text":279,"correct":29},"探测区域应按独立房间划分",{"key":24,"text":281,"correct":22},"一个探测区域的面积不宜超过1000m2",{"key":27,"text":283,"correct":29},"缆式线型感温火灾探测器的探测区域的长度，不宜超过100m",{"key":31,"text":285,"correct":29},"空气管差温火灾探测器的探测区域长度宜为20m～100m",{"id":287,"libraryId":5,"type":230,"typeLabel":231,"stem":288,"options":289,"answer":24,"analysis":37},933373,"下列关于火灾自动报警系统报警区域的划分，说法正确的是（ ）。",[290,292,294,296],{"key":20,"text":291,"correct":29},"电缆隧道的一个报警区域宜由一个封闭长度区间组成，一个报警区域不应超过相连的2个封闭长度区间",{"key":24,"text":293,"correct":22},"甲、乙、丙类液体储罐区的报警区域应由一个储罐区组成，每个50000m3及以上的外浮顶储罐应单独划分为一个报警区域",{"key":27,"text":295,"correct":29},"道路隧道的报警区域应根据排烟系统或灭火系统的联动需要确定，且不宜超过100m",{"key":31,"text":297,"correct":29},"列车的报警区域应按车厢划分，每三节车厢应划分为一个报警区域",{"id":299,"libraryId":5,"type":230,"typeLabel":231,"stem":300,"options":301,"answer":27,"analysis":37},933374,"下列关于火灾探测器选择的说法，不符合规定的是（ ）。",[302,304,306,308],{"key":20,"text":303,"correct":29},"对火灾发展迅速，可产生大量热、烟和火焰辐射的场所，可选择火焰探测器",{"key":24,"text":305,"correct":29},"对使用、生产可燃气体或可燃蒸气的场所，应选择可燃气体探测器",{"key":27,"text":307,"correct":22},"对火灾初期有阴燃阶段，且需要早期探测的场所，宜增设二氧化碳火灾探测器",{"key":31,"text":309,"correct":29},"对火灾发展迅速，有强烈的火焰辐射和少量烟、热的场所，应选择火焰探测器",{"id":311,"libraryId":5,"type":230,"typeLabel":231,"stem":312,"options":313,"answer":24,"analysis":37},933375,"下列场所或地区可以选择点型离子感烟火灾探测器的是（ ）。",[314,316,318,320],{"key":20,"text":315,"correct":29},"气流速度大于5m／s的场所",{"key":24,"text":317,"correct":22},"高海拔地区",{"key":27,"text":319,"correct":29},"产生醇类、醚类、酮类等有机物质的场所",{"key":31,"text":321,"correct":29},"相对湿度经常大于95％的场所",{"id":323,"libraryId":5,"type":230,"typeLabel":231,"stem":324,"options":325,"answer":24,"analysis":37},933376,"根据《火灾自动报警系统设计规范》（GB50116—2013）的规定，消防控制室内的设备面盘前的操作距离，单列布置时不应小于（ ）m，双列布置时不应小于（ ）m。",[326,328,330,332],{"key":20,"text":327,"correct":29},"1．5，3",{"key":24,"text":329,"correct":22},"1．5，2",{"key":27,"text":331,"correct":29},"2，3",{"key":31,"text":333,"correct":29},"2，4",{"id":335,"libraryId":5,"type":230,"typeLabel":231,"stem":336,"options":337,"answer":27,"analysis":37},933377,"根据《火灾自动报警系统设计规范》（GB50116—2013）的规定，每只总线短路隔离器保护的消防设备的总数不应超过（ ）点。",[338,340,342,344],{"key":20,"text":339,"correct":29},"12",{"key":24,"text":341,"correct":29},"26",{"key":27,"text":343,"correct":22},"32",{"key":31,"text":345,"correct":29},"48",{"id":347,"libraryId":5,"type":230,"typeLabel":231,"stem":348,"options":349,"answer":27,"analysis":37},933378,"某办公建筑，内走道宽度为2．8m，长度为22m，该走道顶棚至少应设置（ ）只点型感温火灾探测器。",[350,352,354,356],{"key":20,"text":351,"correct":29},"1",{"key":24,"text":353,"correct":29},"2",{"key":27,"text":355,"correct":22},"3",{"key":31,"text":357,"correct":29},"4",{"id":359,"libraryId":5,"type":230,"typeLabel":231,"stem":360,"options":361,"answer":24,"analysis":37},933379,"当点型探测器倾斜安装时，倾斜角不应大于（ ）。",[362,364,366,368],{"key":20,"text":363,"correct":29},"15°",{"key":24,"text":365,"correct":22},"45°",{"key":27,"text":367,"correct":29},"30°",{"key":31,"text":369,"correct":29},"60°",{"id":371,"libraryId":5,"type":230,"typeLabel":231,"stem":372,"options":373,"answer":24,"analysis":37},933380,"某房间净空高度为4m，设计采用书架将房间分隔为多个区域，当书架顶部至顶棚小于（ ）m时，应在每个被隔开的部分至少安装一只点型探测器。",[374,376,378,380],{"key":20,"text":375,"correct":29},"0．1",{"key":24,"text":377,"correct":22},"0．2",{"key":27,"text":379,"correct":29},"0．3",{"key":31,"text":381,"correct":29},"0．4",{"id":383,"libraryId":5,"type":230,"typeLabel":231,"stem":384,"options":385,"answer":20,"analysis":37},933381,"某展览建筑，建筑面积为3000m2，层高为6m，室内设有格栅吊顶，吊顶镂空面积与吊顶总面积之比为35％，该建筑室内感烟火灾探测器应设置的位置是（ ）。",[386,388,390,392],{"key":20,"text":387,"correct":22},"吊顶上方",{"key":24,"text":389,"correct":29},"吊顶下方",{"key":27,"text":391,"correct":29},"吊顶上方和吊顶下方",{"key":31,"text":393,"correct":29},"根据实际试验结果确定",{"id":395,"libraryId":5,"type":230,"typeLabel":231,"stem":396,"options":397,"answer":27,"analysis":37},933382,"手动火灾报警按钮当采用壁挂方式安装时，其底边距地高度宜为（ ）。",[398,400,402,404],{"key":20,"text":399,"correct":29},"0.8m～1.3m",{"key":24,"text":401,"correct":29},"1.2m～1.5m",{"key":27,"text":403,"correct":22},"1.3m～1.5m",{"key":31,"text":405,"correct":29},"1.5m～1.8m",{"id":407,"libraryId":5,"type":230,"typeLabel":231,"stem":408,"options":409,"answer":20,"analysis":37},933383,"下列关于手动火灾报警设置的说法，错误的是（ ）。",[410,412,414,416],{"key":20,"text":411,"correct":22},"任一防火分区内任一点到最邻近防火分区内的手动火灾报警按钮的步行距离不应大于30m",{"key":24,"text":413,"correct":29},"手动火灾报警按钮宜设置在疏散通道或出入口处",{"key":27,"text":415,"correct":29},"每个防火分区应至少设置一只手动火灾报警按钮",{"key":31,"text":417,"correct":29},"列车上设置的手动火灾报警按钮，应设置在每节车厢的出入口和中间部位",{"id":419,"libraryId":5,"type":230,"typeLabel":231,"stem":420,"options":421,"answer":27,"analysis":37},933384,"某工厂加工车间，环境噪声为65d B，则该车间设置的火灾警报器的声压级不应小于（ ）dB。",[422,424,426,428],{"key":20,"text":423,"correct":29},"60",{"key":24,"text":425,"correct":29},"75",{"key":27,"text":427,"correct":22},"80",{"key":31,"text":429,"correct":29},"85",{"id":431,"libraryId":5,"type":230,"typeLabel":231,"stem":432,"options":433,"answer":31,"analysis":37},933385,"火灾警报器的设置不宜与（ ）设置在同一面墙上。",[434,436,438,440],{"key":20,"text":435,"correct":29},"区域显示器",{"key":24,"text":437,"correct":29},"消防专用电话",{"key":27,"text":439,"correct":29},"应急广播",{"key":31,"text":441,"correct":22},"安全出口指示标志灯具",{"id":443,"libraryId":5,"type":230,"typeLabel":231,"stem":444,"options":445,"answer":27,"analysis":37},933386,"下列关于消防电话分机或电话插孔设置的说法，错误的是（ ）。",[446,448,450,452],{"key":20,"text":447,"correct":29},"防排烟机房应设置消防专用电话分机",{"key":24,"text":449,"correct":29},"消防专用电话分机，应固定安装在明显且便于使用的部位",{"key":27,"text":451,"correct":22},"避难层应每隔30m设置一个消防专用电话分机",{"key":31,"text":453,"correct":29},"电话插孔在墙上安装时，其底边距地面高度宜为1．3m～1．5m",{"id":455,"libraryId":5,"type":230,"typeLabel":231,"stem":456,"options":457,"answer":20,"analysis":37},933387,"下列关于电气火灾监控系统设置的说法，正确的是（ ）。",[458,460,462,464],{"key":20,"text":459,"correct":22},"当线型感温火灾探测器用于电气火灾监控时，可接入电气火灾监控器",{"key":24,"text":461,"correct":29},"非独立式电气火灾监控探测器应接入火灾报警控制器的探测器回路",{"key":27,"text":463,"correct":29},"电气火灾监控系统的设置为不影响供电系统的正常工作，宜自动切断供电电源",{"key":31,"text":465,"correct":29},"在设置消防控制室的场所，电气火灾监控器的报警信息和故障信息应消防控制室图形显示装置上显示，信息与火灾报警信息应相同",{"id":467,"libraryId":5,"type":230,"typeLabel":231,"stem":468,"options":469,"answer":24,"analysis":37},933388,"消防应急广播设置要求，在环境噪声大于（ ）dB的场所设置的扬声器，在其播放范围内最远点的播放声压级应高于背景噪声15dB。",[470,472,473,475],{"key":20,"text":471,"correct":29},"65",{"key":24,"text":423,"correct":22},{"key":27,"text":474,"correct":29},"70",{"key":31,"text":429,"correct":29},{"id":477,"libraryId":5,"type":230,"typeLabel":231,"stem":478,"options":479,"answer":20,"analysis":37},933389,"疏散通道上设置的防火卷帘的联动控制设计规定，防火卷帘下降至距楼板面（ ）m处、下降到楼板面的动作信号和防火卷帘控制器直接连接的感烟、感温火灾探测器的报警信号，应反馈至消防联动控制器。",[480,482,484,486],{"key":20,"text":481,"correct":22},"1．8",{"key":24,"text":483,"correct":29},"1．5",{"key":27,"text":485,"correct":29},"1．3",{"key":31,"text":487,"correct":29},"1．2",{"id":489,"libraryId":5,"type":230,"typeLabel":231,"stem":490,"options":491,"answer":24,"analysis":37},933390,"下列关于火灾自动报警系统探测器选择的说法中，符合现行国家消防技术标准的是（ ）。",[492,494,496,498],{"key":20,"text":493,"correct":29},"可能产生蒸气的无遮挡的高大空间，可以选择线型光束感烟探测器",{"key":24,"text":495,"correct":22},"具有高速气流的场所，可以选择吸气型感烟火灾探测器",{"key":27,"text":497,"correct":29},"燃气站可以选择点型一氧化碳火灾探测器",{"key":31,"text":499,"correct":29},"探测区域内正常情况下有高温物体的场所，可以选择单波段红外火焰探测器",{"id":501,"libraryId":5,"type":230,"typeLabel":231,"stem":502,"options":503,"answer":20,"analysis":37},933391,"消防控制室图形显示装置应能在接收到火灾报警信号或联动信号后（ ）s内，将相应信息按规定的通信协议格式传送给监控中心。",[504,506,508,509],{"key":20,"text":505,"correct":22},"10",{"key":24,"text":507,"correct":29},"30",{"key":27,"text":423,"correct":29},{"key":31,"text":510,"correct":29},"90",{"id":512,"libraryId":5,"type":230,"typeLabel":231,"stem":513,"options":514,"answer":31,"analysis":37},933392,"设置两个及两个以上消防控制室的保护对象，或已设置两个及两个以上集中报警系统的保护对象，应采用（ ）。",[515,516,517,519],{"key":20,"text":45,"correct":29},{"key":24,"text":47,"correct":29},{"key":27,"text":518,"correct":29},"局部报警系统",{"key":31,"text":49,"correct":22},{"id":521,"libraryId":5,"type":230,"typeLabel":231,"stem":522,"options":523,"answer":27,"analysis":37},933393,"在宽度小于3m的内走道顶棚上设置点型探测器时，感烟火灾探测器的安装间距不应超过（ ）m。",[524,526,527,529],{"key":20,"text":525,"correct":29},"8",{"key":24,"text":505,"correct":29},{"key":27,"text":528,"correct":22},"15",{"key":31,"text":530,"correct":29},"20",{"id":532,"libraryId":5,"type":230,"typeLabel":231,"stem":533,"options":534,"answer":24,"analysis":37},933394,"下列关于火灾探测器的选择正确的是（ ）。",[535,537,538,540],{"key":20,"text":536,"correct":29},"对火灾初期有阴燃阶段，产生大量的烟和少量的热，很少或没有火焰辐射的场所，应选择感温火灾探测器",{"key":24,"text":305,"correct":22},{"key":27,"text":539,"correct":29},"饭店、旅馆宜选择点型感温火灾探测器",{"key":31,"text":541,"correct":29},"可能产生腐蚀性气体的场所，应选择点型离子感烟火灾探测器",{"id":543,"libraryId":5,"type":230,"typeLabel":231,"stem":544,"options":545,"answer":20,"analysis":37},933395,"在宽度小于3m的内走道顶棚上设置点型感温火灾探测器，其安装间距不应超过（ ）。",[546,548,550,552],{"key":20,"text":547,"correct":22},"10m",{"key":24,"text":549,"correct":29},"15m",{"key":27,"text":551,"correct":29},"20m",{"key":31,"text":553,"correct":29},"25m",{"id":555,"libraryId":5,"type":230,"typeLabel":231,"stem":556,"options":557,"answer":31,"analysis":37},933396,"从一个防火分区内的任何位置到最邻近的手动火灾报警按钮的步行距离不应大于（ ）。",[558,559,560,561],{"key":20,"text":547,"correct":29},{"key":24,"text":549,"correct":29},{"key":27,"text":551,"correct":29},{"key":31,"text":562,"correct":22},"30m",{"id":564,"libraryId":5,"type":230,"typeLabel":231,"stem":565,"options":566,"answer":20,"analysis":37},933397,"在气体灭火系统中，下列动作信号属于联动反馈信号的是（ ）。",[567,569,571,573],{"key":20,"text":568,"correct":22},"选择阀开启后的动作信号",{"key":24,"text":570,"correct":29},"启动气体灭火装置的动作信号",{"key":27,"text":572,"correct":29},"关闭防护区送风机的动作信号",{"key":31,"text":574,"correct":29},"手动火灾报警按钮的动作信号",{"id":576,"libraryId":5,"type":230,"typeLabel":231,"stem":577,"options":578,"answer":31,"analysis":37},933398,"某综合楼内设置火灾自动报警系统，自动喷水灭火系统，下列关于火灾自动报警系统组件设置的做法中，不正确的是（）。",[579,581,583,585],{"key":20,"text":580,"correct":29},"区域显示器当采用壁挂方式安装时，安装高度为1．3m",{"key":24,"text":582,"correct":29},"电话插孔在墙上安装时，其底边距地面高度为1．4m",{"key":27,"text":584,"correct":29},"电动开门器的手动控制按钮安装在防火门内侧墙面上，距门的距离为0．5m",{"key":31,"text":586,"correct":22},"火灾报警控制器安装在墙上，其主显示屏高度为1．1m",{"id":588,"libraryId":5,"type":230,"typeLabel":231,"stem":589,"options":590,"answer":31,"analysis":37},933399,"火灾自动报警系统中，系统模块严禁设置在（ ）内。",[591,593,595,596],{"key":20,"text":592,"correct":29},"电梯井内",{"key":24,"text":594,"correct":29},"电缆井内",{"key":27,"text":66,"correct":29},{"key":31,"text":597,"correct":22},"配电柜",{"id":599,"libraryId":5,"type":230,"typeLabel":231,"stem":600,"options":601,"answer":31,"analysis":37},933400,"线型可燃气体探测器的保护区域长度不宜大于（ ）m。",[602,603,605,607],{"key":20,"text":507,"correct":29},{"key":24,"text":604,"correct":29},"40",{"key":27,"text":606,"correct":29},"50",{"key":31,"text":423,"correct":22},{"id":609,"libraryId":5,"type":230,"typeLabel":231,"stem":610,"options":611,"answer":27,"analysis":37},933401,"对于可能散发相对密度比空气重的可燃气体场所，可燃气体探测器应设置在该场所室内空间的（ ）。",[612,614,616,618],{"key":20,"text":613,"correct":29},"顶部",{"key":24,"text":615,"correct":29},"中间高度位置或下部",{"key":27,"text":617,"correct":22},"下部",{"key":31,"text":619,"correct":29},"中间高度",{"id":621,"libraryId":5,"type":230,"typeLabel":231,"stem":622,"options":623,"answer":27,"analysis":37},933402,"电气火灾监控系统应根据建筑物的性质及电气火灾危险性设置，在无消防控制室且电气火灾监控探测器设置数量不超过（ ）只时，可采用独立式电气火灾监控探测器。",[624,625,627,628],{"key":20,"text":357,"correct":29},{"key":24,"text":626,"correct":29},"6",{"key":27,"text":525,"correct":22},{"key":31,"text":505,"correct":29},{"id":630,"libraryId":5,"type":230,"typeLabel":231,"stem":631,"options":632,"answer":31,"analysis":37},933403,"根据《火灾自动报警系统设计规范》（GB50116—2013）的规定，当电器火灾监控系统用于保护1kV及以下配电线路时，（ ）应采用接触式布置。",[633,635,637,639],{"key":20,"text":634,"correct":29},"剩余电流火灾监控探测器",{"key":24,"text":636,"correct":29},"故障电弧式电气火灾监控探测器",{"key":27,"text":638,"correct":29},"线型感温火灾探测器",{"key":31,"text":640,"correct":22},"测温式电气火灾监控探测器",[642,645,648,651,654,657],{"id":230,"name":643,"category":7,"favorite":644},"领导干部任职前廉政法规知识测试题",92,{"id":646,"name":647,"category":7,"favorite":230},595,"建筑结构与设备",{"id":649,"name":650,"category":7,"favorite":230},715,"招标采购专业知识与法律法规",{"id":652,"name":653,"category":7,"favorite":230},848,"市政方向-通用基础",{"id":655,"name":656,"category":7,"favorite":8},534,"BIM工程师",{"id":658,"name":656,"category":7,"favorite":8},535]