[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-33":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":615},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,33,50,2960,[13,34,46,58,66,78,90,102,114,124,136,154,166,179,194,209,224,236,248,260,272,284,295,307,319,329,341,351,363,373,382,394,406,418,430,439,451,463,475,487,499,511,523,534,546,558,570,582,594,604],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},933304,1,"单选题","（ ）是泡沫从储罐底部注入，并通过软管浮升到燃烧液体表面进行喷放的泡沫灭火系统。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","半固定式系统",false,{"key":24,"text":25,"correct":22},"B","液上喷射系统",{"key":27,"text":28,"correct":22},"C","液下喷射系统",{"key":30,"text":31,"correct":32},"D","半液下喷射系统",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},933305,"某储罐区采用外浮顶储罐存储非水溶性液体，储罐上设置的固定式泡沫灭火系统的泡沫混合液连续供给时间为30min，系统混合液供给强度不应小于（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":32},"12．5L／（minm2）",{"key":24,"text":41,"correct":22},"12L／（minm2）",{"key":27,"text":43,"correct":22},"11L／（minm2）",{"key":30,"text":45,"correct":22},"10L／（minm2）",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},933306,"某储存石油、轻石脑油的储蓄罐，采用内浮顶罐，储罐上所设置的固定式泡沫灭火系统的泡沫混合液供给强度为12．5L／（min·m2），连续供给时间不应小于（ ）min。",[50,52,54,56],{"key":20,"text":51,"correct":22},"25",{"key":24,"text":53,"correct":32},"30",{"key":27,"text":55,"correct":22},"40",{"key":30,"text":57,"correct":22},"45",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},933307,"某中型化工厂储存重油的储罐区，采用固定顶罐，储罐上所设置的固定式液下喷射泡沫灭火系统的泡沫混合液供给强度为5.0L\u002F（minm2），连续供给时间不应小于（ ）min。",[62,63,64,65],{"key":20,"text":51,"correct":22},{"key":24,"text":53,"correct":22},{"key":27,"text":55,"correct":32},{"key":30,"text":57,"correct":22},{"id":67,"libraryId":5,"type":15,"typeLabel":16,"stem":68,"options":69,"answer":27,"analysis":33},933308,"发泡倍数为20～200、在实际工程中多用作辅助灭火设施的泡沫灭火系统是（ ）。",[70,72,74,76],{"key":20,"text":71,"correct":22},"泡沫枪系统",{"key":24,"text":73,"correct":22},"低倍数泡沫灭火系统",{"key":27,"text":75,"correct":32},"中倍数泡沫灭火系统",{"key":30,"text":77,"correct":22},"高倍数泡沫灭火系统",{"id":79,"libraryId":5,"type":15,"typeLabel":16,"stem":80,"options":81,"answer":27,"analysis":33},933309,"下列关于泡沫灭火系统泡沫液选择的说法中，不正确的是（ ）。",[82,84,86,88],{"key":20,"text":83,"correct":22},"水溶性甲、乙、丙类液体必须选用抗溶泡沫液",{"key":24,"text":85,"correct":22},"保护非水溶性液体的泡沫液的选择，当采用非吸气型喷射装置时，应选用水成膜或成膜氟蛋白泡沫液",{"key":27,"text":87,"correct":32},"一套系统同时保护水溶性和非水溶性甲、乙、丙类液体的，可选用非抗溶泡沫液",{"key":30,"text":89,"correct":22},"对普通泡沫有破坏作用的甲、乙、丙类液体必须选用抗溶泡沫液",{"id":91,"libraryId":5,"type":15,"typeLabel":16,"stem":92,"options":93,"answer":30,"analysis":33},933310,"下列关于泡沫灭火系统泡沫液泵的说法中，不正确的是（）。",[94,96,98,100],{"key":20,"text":95,"correct":22},"应设置备用泵，备用泵的规格型号应与工作泵相同，且工作泵故障时应能自动与手动切换到备用泵",{"key":24,"text":97,"correct":22},"泡沫液泵应能耐受不低于10min的空载运转",{"key":27,"text":99,"correct":22},"泡沫液泵的工作压力和流量应满足系统最大设计要求，同时应保证在设计流量范围内泡沫液供给压力大于最大水压力",{"key":30,"text":101,"correct":32},"泡沫液泵的动力源设置应符合相关规范要求，且宜与系统泡沫消防水泵的动力源一致",{"id":103,"libraryId":5,"type":15,"typeLabel":16,"stem":104,"options":105,"answer":30,"analysis":33},933311,"移动式高倍数泡沫灭火系统不能应用于下列（ ）场所。",[106,108,110,112],{"key":20,"text":107,"correct":22},"发生火灾的部位难以确定或人员难以接近的火灾场所",{"key":24,"text":109,"correct":22},"流淌的 B 类火灾场",{"key":27,"text":111,"correct":22},"发生火灾时需要排烟、降温或排除有害气体的封闭场所",{"key":30,"text":113,"correct":32},"天然气液化站与接收站的集液池或储罐围堰区",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":20,"analysis":33},933312,"低倍数泡沫灭火系统是指发泡倍数小于（ ）的泡沫灭火系统。",[118,120,121,122],{"key":20,"text":119,"correct":32},"20",{"key":24,"text":53,"correct":22},{"key":27,"text":55,"correct":22},{"key":30,"text":123,"correct":22},"50",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":20,"analysis":33},933313,"局部应用式中倍数泡沫灭火系统不可用于（ ）。",[128,130,132,134],{"key":20,"text":129,"correct":32},"四周完全封闭的A类火灾场所",{"key":24,"text":131,"correct":22},"四周不完全封闭的A类火灾场所",{"key":27,"text":133,"correct":22},"限定位置的流散B类火灾场所",{"key":30,"text":135,"correct":22},"固定位置面积不大于100m2的流淌B类火灾场所",{"id":137,"libraryId":5,"type":138,"typeLabel":139,"stem":140,"options":141,"answer":153,"analysis":33},933314,2,"多选题","泡沫灭火系统是通过机械作用将泡沫灭火剂、水与空气充分混合并产生泡沫实施灭火的灭火系统。下列属于泡沫灭火系统主要灭火机理的是（ ）。",[142,144,146,148,150],{"key":20,"text":143,"correct":32},"隔氧窒息",{"key":24,"text":145,"correct":32},"吸热冷却",{"key":27,"text":147,"correct":22},"稀释",{"key":30,"text":149,"correct":32},"辐射热阻隔",{"key":151,"text":152,"correct":22},"E","化学抑制","ABD",{"id":155,"libraryId":5,"type":138,"typeLabel":139,"stem":156,"options":157,"answer":165,"analysis":33},933315,"泡沫灭火系统的灭火机理有（ ）作用。",[158,159,161,162,164],{"key":20,"text":149,"correct":32},{"key":24,"text":160,"correct":22},"乳化阻隔",{"key":27,"text":143,"correct":32},{"key":30,"text":163,"correct":22},"浸湿作用",{"key":151,"text":145,"correct":32},"ACE",{"id":167,"libraryId":5,"type":138,"typeLabel":139,"stem":168,"options":169,"answer":178,"analysis":33},933316,"下列选项中，属于干粉灭火系统主要灭火机理的有（ ）。",[170,171,172,174,176],{"key":20,"text":152,"correct":32},{"key":24,"text":147,"correct":22},{"key":27,"text":173,"correct":32},"隔离",{"key":30,"text":175,"correct":32},"冷却窒息",{"key":151,"text":177,"correct":22},"乳化","ACD",{"id":180,"libraryId":5,"type":138,"typeLabel":139,"stem":181,"options":182,"answer":193,"analysis":33},933317,"下列关于干粉灭火系统储存装置的说法，正确的有（ ）。",[183,185,187,189,191],{"key":20,"text":184,"correct":22},"干粉储存容器应符合国家现行标准《气瓶安全监察规程》的规定",{"key":24,"text":186,"correct":22},"驱动气体储瓶及其充装系数应符合国家现行标准《压力容器安全技术监察规程》的规定",{"key":27,"text":188,"correct":32},"干粉储存容器设计压力可取1．6MPa或2．5MPa压力级",{"key":30,"text":190,"correct":32},"安全泄压装置的动作压力及额定排放量应按现行国家标准《干粉灭火系统部件通用技术条件》GB16668执行",{"key":151,"text":192,"correct":32},"干粉储存容器应满足驱动气体系数、干粉储存量、输出容器阀出口干粉输送速率和压力的要求","CDE",{"id":195,"libraryId":5,"type":138,"typeLabel":139,"stem":196,"options":197,"answer":208,"analysis":33},933318,"干粉灭火系统预制灭火装置应符合的规定有（ ）。",[198,200,202,204,206],{"key":20,"text":199,"correct":22},"灭火剂储存量不得大于100kg",{"key":24,"text":201,"correct":32},"灭火剂储存量不得大于150kg",{"key":27,"text":203,"correct":22},"管道长度不得大于15m",{"key":30,"text":205,"correct":32},"管道长度不得大于20m",{"key":151,"text":207,"correct":32},"工作压力不得大于2．5MPa","BDE",{"id":210,"libraryId":5,"type":138,"typeLabel":139,"stem":211,"options":212,"answer":223,"analysis":33},933319,"下列火灾类型中，不可以采用干粉灭火系统的是（）。",[213,215,217,219,221],{"key":20,"text":214,"correct":22},"灭火前可切断气源的气体火灾",{"key":24,"text":216,"correct":22},"易燃、可燃液体和可熔化固体火灾",{"key":27,"text":218,"correct":32},"硝化纤维火灾",{"key":30,"text":220,"correct":22},"带电设备火灾",{"key":151,"text":222,"correct":32},"氢化钾火灾","CE",{"id":225,"libraryId":5,"type":15,"typeLabel":16,"stem":226,"options":227,"answer":30,"analysis":33},933320,"驱动气体（氮气或二氧化碳）单独储存在储气瓶中，灭火使用时，再将驱动气体充入干粉储罐，进而携带驱动干粉喷射实施灭火是（ ）的作用过程。",[228,230,232,234],{"key":20,"text":229,"correct":22},"储压式干粉灭火系统",{"key":24,"text":231,"correct":22},"燃气式干粉灭火系统",{"key":27,"text":233,"correct":22},"设计型干粉灭火系统",{"key":30,"text":235,"correct":32},"储气式干粉灭火系统",{"id":237,"libraryId":5,"type":15,"typeLabel":16,"stem":238,"options":239,"answer":27,"analysis":33},933321,"某建筑内一防护区，采用全淹没式干粉灭火系统保护，下列做法中不符合《干粉灭火系统设计规范》（GB50347--2004）规定的是（ ）。",[240,242,244,246],{"key":20,"text":241,"correct":22},"防护区门窗耐火极限为0．50h",{"key":24,"text":243,"correct":22},"防护区吊顶耐火极限为0．50h",{"key":27,"text":245,"correct":32},"防护区底面设有多个换气通风口",{"key":30,"text":247,"correct":22},"围护结构的允许压力为1500Pa",{"id":249,"libraryId":5,"type":15,"typeLabel":16,"stem":250,"options":251,"answer":30,"analysis":33},933322,"某建筑设置了组合分配干粉灭火系统。下列关于该系统的保护对象数量的说法，正确的是（ ）。",[252,254,256,258],{"key":20,"text":253,"correct":22},"防护区与保护对象之和不得超过4个",{"key":24,"text":255,"correct":22},"防护区与保护对象之和不应少于4个",{"key":27,"text":257,"correct":22},"防护区与保护对象之和不应少于8个",{"key":30,"text":259,"correct":32},"防护区与保护对象之和不得超过8个",{"id":261,"libraryId":5,"type":15,"typeLabel":16,"stem":262,"options":263,"answer":30,"analysis":33},933323,"组合分配干粉灭火系统中，当防护区与保护对象之和超过（ ）个时，或者在喷放后（ ）h内不能恢复到正常工作状态时，灭火剂应有备用量。",[264,266,268,270],{"key":20,"text":265,"correct":22},"4，24",{"key":24,"text":267,"correct":22},"5，24",{"key":27,"text":269,"correct":22},"4，48",{"key":30,"text":271,"correct":32},"5，48",{"id":273,"libraryId":5,"type":15,"typeLabel":16,"stem":274,"options":275,"answer":24,"analysis":33},933324,"当采用局部应用干粉灭火系统保护室外或有复燃危险的室内场所时，该灭火系统的干粉喷射时间不应小于（ ）min。",[276,278,280,282],{"key":20,"text":277,"correct":22},"0．5",{"key":24,"text":279,"correct":32},"1",{"key":27,"text":281,"correct":22},"1．5",{"key":30,"text":283,"correct":22},"2",{"id":285,"libraryId":5,"type":15,"typeLabel":16,"stem":286,"options":287,"answer":27,"analysis":33},933325,"某场所内部设置了预制干粉灭火装置，下列关于该装置的说法中，正确的是（ ）。",[288,290,292,293],{"key":20,"text":289,"correct":22},"灭火剂储存量不得大于120kg",{"key":24,"text":291,"correct":22},"管道长度不得大于25m",{"key":27,"text":207,"correct":32},{"key":30,"text":294,"correct":22},"一个防护区或保护对象宜用多套预制灭火装置保护",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":24,"analysis":33},933326,"某场所采用干粉灭火系统保护，当采用全淹没系统时，该系统的灭火剂设计浓度不得小于（ ）kg／m3。",[299,301,303,305],{"key":20,"text":300,"correct":22},"0．55",{"key":24,"text":302,"correct":32},"0．65",{"key":27,"text":304,"correct":22},"0．75",{"key":30,"text":306,"correct":22},"0．85",{"id":308,"libraryId":5,"type":15,"typeLabel":16,"stem":309,"options":310,"answer":30,"analysis":33},933327,"干粉灭火系统的驱动气体应优先选用（ ）。",[311,313,315,317],{"key":20,"text":312,"correct":22},"卤代烷",{"key":24,"text":314,"correct":22},"二氧化碳",{"key":27,"text":316,"correct":22},"氩气",{"key":30,"text":318,"correct":32},"氮气",{"id":320,"libraryId":5,"type":15,"typeLabel":16,"stem":321,"options":322,"answer":27,"analysis":33},933328,"干粉灭火系统的干粉储存容器，其干粉灭火剂的装量系数不应大于（ ）。",[323,324,326,327],{"key":20,"text":304,"correct":22},{"key":24,"text":325,"correct":22},"0．8",{"key":27,"text":306,"correct":32},{"key":30,"text":328,"correct":22},"0．9",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":24,"analysis":33},933329,"下列关于选择阀的说法，错误的是（ ）。",[333,335,337,339],{"key":20,"text":334,"correct":22},"在组合分配系统中，每个防护区或保护对象应设一个选择阀",{"key":24,"text":336,"correct":32},"选择阀的位置宜远离干粉储存容器，并便于自动操作，方便检查和维护",{"key":27,"text":338,"correct":22},"选择阀上应设有标明防护区的永久性铭牌",{"key":30,"text":340,"correct":22},"选择阀应采用快开型阀门，其公称直径应与连接管道的公称直径相等",{"id":342,"libraryId":5,"type":15,"typeLabel":16,"stem":343,"options":344,"answer":20,"analysis":33},933330,"某场所采用火灾自动报警系统和干粉灭火系统保护，当干粉灭火系统启动时，该系统的延迟喷射时间不应大于（ ）s。",[345,346,347,349],{"key":20,"text":53,"correct":32},{"key":24,"text":57,"correct":22},{"key":27,"text":348,"correct":22},"60",{"key":30,"text":350,"correct":22},"90",{"id":352,"libraryId":5,"type":15,"typeLabel":16,"stem":353,"options":354,"answer":24,"analysis":33},933331,"下列关于干粉灭火系统组件设置的说法，错误的是（ ）。",[355,357,359,361],{"key":20,"text":356,"correct":22},"全淹没灭火系统的手动启动装置应设置在防护区外邻近出口或疏散通道便于操作的地方",{"key":24,"text":358,"correct":32},"局部应用灭火系统的手动启动装置应设在疏散通道便于操作的地方",{"key":27,"text":360,"correct":22},"手动启动装置的安装高度宜使其中心位置距地面1．5m",{"key":30,"text":362,"correct":22},"所有手动启动装置都应明显地标示出其对应的防护区或保护对象的名称",{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":27,"analysis":33},933332,"干粉灭火系统启动方式应有（ ）种。",[367,368,369,371],{"key":20,"text":279,"correct":22},{"key":24,"text":283,"correct":22},{"key":27,"text":370,"correct":32},"3",{"key":30,"text":372,"correct":22},"4",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":27,"analysis":33},933333,"全淹没系统干粉灭火剂喷射时间一般不大于（ ）s。",[377,379,380,381],{"key":20,"text":378,"correct":22},"10",{"key":24,"text":119,"correct":22},{"key":27,"text":53,"correct":32},{"key":30,"text":55,"correct":22},{"id":383,"libraryId":5,"type":15,"typeLabel":16,"stem":384,"options":385,"answer":27,"analysis":33},933334,"下列场所发生火灾不能使用干粉灭火系统的是（ ）。",[386,388,390,392],{"key":20,"text":387,"correct":22},"石油储罐",{"key":24,"text":389,"correct":22},"油泵房",{"key":27,"text":391,"correct":32},"镁粉厂房",{"key":30,"text":393,"correct":22},"发电机房",{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":30,"analysis":33},933335,"采用全淹没干粉灭火系统的防护区，不符合规定的是（ ）。",[398,400,402,404],{"key":20,"text":399,"correct":22},"防护区的围护结构及门、窗的耐火极限不应小于0．50h",{"key":24,"text":401,"correct":22},"围护结构及门、窗的允许压力不宜小于1200Pa",{"key":27,"text":403,"correct":22},"采用全淹没式的组合分配系统保护的防护区与保护对象之和不得超过8个",{"key":30,"text":405,"correct":32},"喷放干粉时不能自动关闭的防护区开口，其总面积不应大于该防护区总内表面积的20％",{"id":407,"libraryId":5,"type":15,"typeLabel":16,"stem":408,"options":409,"answer":20,"analysis":33},933336,"为了保证干粉实际喷射的灭火效果， 下列关于干粉灭火系统设置要求的说法中，错误的是（ ）。",[410,412,414,416],{"key":20,"text":411,"correct":32},"全淹没灭火系统的干粉喷射时间不应小于 30s",{"key":24,"text":413,"correct":22},"室内局部应用灭火系统的干粉喷射时间不应小于 30s",{"key":27,"text":415,"correct":22},"室外或有复燃危险的室内局部应用灭火系统的干粉喷射时间不应小于 60s",{"key":30,"text":417,"correct":22},"一个防护区或保护对象所用多套预制灭火装置其动作响应时间差不得大于 2s",{"id":419,"libraryId":5,"type":15,"typeLabel":16,"stem":420,"options":421,"answer":30,"analysis":33},933337,"对于储压型系统，当釆用全淹没灭火系统时，喷头的最大安装高度不大于（ ）m；当采用局部应用系统时，喷头最大安装高度不大于（ ）m。",[422,424,426,428],{"key":20,"text":423,"correct":22},"5 6",{"key":24,"text":425,"correct":22},"6 5",{"key":27,"text":427,"correct":22},"8 7",{"key":30,"text":429,"correct":32},"7 6",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":24,"analysis":33},933338,"室外或有复燃危险的室内局部应用灭火系统的干粉喷射时间不应小于（ ）s。",[434,435,436,437],{"key":20,"text":53,"correct":22},{"key":24,"text":348,"correct":32},{"key":27,"text":350,"correct":22},{"key":30,"text":438,"correct":22},"120",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":27,"analysis":33},933339,"储存装置宜设在专用的储存装置间内，专用储存装置间的设置不正确的是（ ）。",[443,445,447,449],{"key":20,"text":444,"correct":22},"靠近防护区",{"key":24,"text":446,"correct":22},"出口直接通向室外或疏散通道",{"key":27,"text":448,"correct":32},"耐火等级为三级",{"key":30,"text":450,"correct":22},"宜保持干燥和良好通风，并应设应急照明",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":20,"analysis":33},933340,"常用的普通干粉灭火剂不能用于扑灭（ ）火灾。",[455,457,459,461],{"key":20,"text":456,"correct":32},"A类",{"key":24,"text":458,"correct":22},"B类",{"key":27,"text":460,"correct":22},"C类",{"key":30,"text":462,"correct":22},"E类",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":20,"analysis":33},933341,"干粉灭火系统储存装置宜设在专用的储存装置间内。专用储存装置间的设置应符合规定的说法错误的是（ ）。",[467,469,471,473],{"key":20,"text":468,"correct":32},"应靠近消防控制室",{"key":24,"text":470,"correct":22},"出口应直接通向室外或疏散通道",{"key":27,"text":472,"correct":22},"耐火等级不应低于二级",{"key":30,"text":474,"correct":22},"宜保持干燥和良好通风",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":24,"analysis":33},933342,"下列关于干粉灭火系统的设置，不符合规范要求的是（ ）。",[479,481,483,485],{"key":20,"text":480,"correct":22},"一个防护区或保护对象所用预制灭火装置4套，且同时启动其动作响应时间差为2s",{"key":24,"text":482,"correct":32},"采用预制灭火系统时，管道长度为25m",{"key":27,"text":484,"correct":22},"组合分配选择阀采用快开型阀门，其公称直径与连接管道的公称直径相等",{"key":30,"text":486,"correct":22},"干粉喷头的单孔直径为8mm",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":30,"analysis":33},933343,"下列不属于普通干粉灭火剂的是（ ）。",[491,493,495,497],{"key":20,"text":492,"correct":22},"以碳酸氢钠为基料的钠盐干粉灭火剂",{"key":24,"text":494,"correct":22},"以氯化钾为基料的超级钾盐干粉灭火剂",{"key":27,"text":496,"correct":22},"以硫酸钾为基料的钾盐干粉灭火剂",{"key":30,"text":498,"correct":32},"以磷酸铵和硫酸铵混合物为基料的干粉灭火剂",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":30,"analysis":33},933344,"多用途干粉灭火剂不适宜扑救的火灾是（ ）。",[503,505,507,509],{"key":20,"text":504,"correct":22},"A类火灾",{"key":24,"text":506,"correct":22},"B类火灾",{"key":27,"text":508,"correct":22},"C类火灾",{"key":30,"text":510,"correct":32},"D类火灾",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":27,"analysis":33},933345,"干粉灭火系统由干粉灭火设备和自动控制两大部分组成，下列属于自动控制组成部分的是（ ）。",[515,517,519,521],{"key":20,"text":516,"correct":22},"干粉储存容器",{"key":24,"text":518,"correct":22},"驱动气体瓶组",{"key":27,"text":520,"correct":32},"信号反馈装置",{"key":30,"text":522,"correct":22},"减压阀",{"id":524,"libraryId":5,"type":15,"typeLabel":16,"stem":525,"options":526,"answer":20,"analysis":33},933346,"干粉灭火系统根据其应用方式、系统保护情况、驱动气体储存方式等不同可分为多种类型，下列属于按应用方式分类的是（ ）。",[527,529,531,533],{"key":20,"text":528,"correct":32},"全淹没干粉灭火系统",{"key":24,"text":530,"correct":22},"预制型干粉灭火系统",{"key":27,"text":532,"correct":22},"组合分配系统",{"key":30,"text":235,"correct":22},{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":20,"analysis":33},933347,"下列关于局部应用式干粉灭火系统的说法，错误的是（ ）。",[538,540,542,544],{"key":20,"text":539,"correct":32},"保护对象周围的空气流动速度不应大于3m／s",{"key":24,"text":541,"correct":22},"喷头和保护对象之间，喷头喷射角范围内不应有遮挡物",{"key":27,"text":543,"correct":22},"保护对象为可燃液体时，液面至容器缘口的距离不得小于150mm",{"key":30,"text":545,"correct":22},"保护对象有可燃气体，易燃、可燃液体供应源时，启动干粉灭火系统之前或同时，必须切断气体、液体的供应源",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":20,"analysis":33},933348,"干粉灭火系统按灭火方式分类，包括（ ）。",[550,552,554,556],{"key":20,"text":551,"correct":32},"全淹没干粉灭火系统、局部应用干粉灭火系统",{"key":24,"text":553,"correct":22},"储气式干粉灭火系统、储压式干粉灭火系统、燃气式干粉灭火系统",{"key":27,"text":555,"correct":22},"设计型干粉灭火系统、预制型干粉灭火系统",{"key":30,"text":557,"correct":22},"组合分配系统、单元独立系统",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":24,"analysis":33},933349,"某中型变电站内的油浸变压器采用局部应用干粉灭火装置进行保护，下列关于该装置设置要求中，错误的是（ ）。",[562,564,566,568],{"key":20,"text":563,"correct":22},"系统设置的手动启动装置应设在保护对象附近的安全位置",{"key":24,"text":565,"correct":32},"手动启动装置的安装高度宜使其中心位置距地面1.6m",{"key":27,"text":567,"correct":22},"应设置火灾声光警报器",{"key":30,"text":569,"correct":22},"保护对象周围的空气流动速度不应大于2m\u002Fs",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":30,"analysis":33},933350,"下列关于灭火剂的相容性，说法正确的是（ ）。",[574,576,578,580],{"key":20,"text":575,"correct":22},"碳酸氢钠灭火剂与蛋白泡沫相容",{"key":24,"text":577,"correct":22},"蛋白泡沫灭火剂与水成膜泡沫灭火剂相容",{"key":27,"text":579,"correct":22},"碳酸氢钠灭火剂与磷酸铵盐灭火剂相容",{"key":30,"text":581,"correct":32},"磷酸铵盐灭火剂与蛋白泡沫灭火剂相容",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":20,"analysis":33},933351,"可燃气体，易燃、可燃液体和可熔化固体火灾宜采用（ ）干粉灭火剂。",[586,588,590,592],{"key":20,"text":587,"correct":32},"碳酸氢钠",{"key":24,"text":589,"correct":22},"磷酸铵盐",{"key":27,"text":591,"correct":22},"氯化钠",{"key":30,"text":593,"correct":22},"硫酸钾",{"id":595,"libraryId":5,"type":15,"typeLabel":16,"stem":596,"options":597,"answer":27,"analysis":33},933352,"全淹没干粉灭火系统应均匀分布，喷头与墙的距离不大于（ ）m。",[598,599,601,602],{"key":20,"text":277,"correct":22},{"key":24,"text":600,"correct":22},"0．7",{"key":27,"text":279,"correct":32},{"key":30,"text":603,"correct":22},"1．2",{"id":605,"libraryId":5,"type":138,"typeLabel":139,"stem":606,"options":607,"answer":614,"analysis":33},933353,"多用途干粉灭火剂可用于扑灭（ ）火灾。",[608,609,610,611,613],{"key":20,"text":456,"correct":32},{"key":24,"text":458,"correct":32},{"key":27,"text":460,"correct":32},{"key":30,"text":612,"correct":22},"D类",{"key":151,"text":462,"correct":32},"ABCE",[616,619,622,625,628,631],{"id":15,"name":617,"category":7,"favorite":618},"领导干部任职前廉政法规知识测试题",92,{"id":620,"name":621,"category":7,"favorite":15},595,"建筑结构与设备",{"id":623,"name":624,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":626,"name":627,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":629,"name":630,"category":7,"favorite":8},534,"BIM工程师",{"id":632,"name":630,"category":7,"favorite":8},535]