[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-32":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":606},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,32,50,2960,[13,34,46,58,70,82,94,106,118,130,141,153,171,186,201,216,231,245,257,269,281,290,302,314,323,335,347,359,368,380,392,404,416,428,440,450,460,468,478,488,497,509,521,529,537,549,558,570,582,594],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},933254,1,"单选题","下列火灾中，不可以采用七氟丙烷气体灭火系统进行扑救的是（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","电气火灾",false,{"key":24,"text":25,"correct":22},"B","固体表面火灾",{"key":27,"text":28,"correct":22},"C","灭火前可切断气源的气体火灾",{"key":30,"text":31,"correct":32},"D","金属氢化物火灾",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},933255,"某通信机房单独划分为一个防护区，采用七氟丙烷预制灭火系统保护，则该防护区预制灭火装置数量不宜超过（ ）台。",[38,40,42,44],{"key":20,"text":39,"correct":22},"5",{"key":24,"text":41,"correct":22},"8",{"key":27,"text":43,"correct":32},"10",{"key":30,"text":45,"correct":22},"12",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},933256,"下列关于气体灭火系统防护区划分说法中，正确的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"同一区间的吊顶层和地板下需同时保护时，应划分为两个防护区",{"key":24,"text":53,"correct":32},"防护区宜以单个封闭空间划分",{"key":27,"text":55,"correct":22},"采用预制灭火系统时，一个防护区的面积不宜大于800m2，且容积不宜大于3600m3",{"key":30,"text":57,"correct":22},"采用管网灭火系统时，一个防护区的面积不宜大于500m2，且容积不宜大于1600m3",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},933257,"下列关于气体灭火系统安全要求的说法，错误的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"系统管网、壳体等金属件经过有爆炸危险及变电、配电室等场所时应设防静电接地",{"key":24,"text":65,"correct":32},"有人工作防护区的灭火设计浓度或实际使用浓度应大于有毒性反应浓度",{"key":27,"text":67,"correct":22},"防护区的门应向疏散方向开启，并能自行关闭",{"key":30,"text":69,"correct":22},"设有气体灭火系统的场所，宜配置空气呼吸器",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},933258,"某通信机房设置IG541气体灭火系统保护，当IG541混合气体灭火剂喷放至设计用量的95％时，其喷放时间不应大于（ ）S且不应小于（ ）s。",[74,76,78,80],{"key":20,"text":75,"correct":22},"60，30",{"key":24,"text":77,"correct":32},"60，48",{"key":27,"text":79,"correct":22},"30，8",{"key":30,"text":81,"correct":22},"30，10",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},933259,"低压二氧化碳储存容器的设计工作压力不应小于（ ）MPa。",[86,88,90,92],{"key":20,"text":87,"correct":32},"2．5",{"key":24,"text":89,"correct":22},"1．5",{"key":27,"text":91,"correct":22},"2．2",{"key":30,"text":93,"correct":22},"1．8",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":30,"analysis":33},933260,"某计算机主机房设置组合分配式七氟丙烷灭火系统保护，下列关于该系统的做法中，错误的是（）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"系统设置自动控制、手动控制和机械应急控制三种启动方式",{"key":24,"text":101,"correct":22},"选择阀设计在容器阀开启前打开",{"key":27,"text":103,"correct":22},"集流管上设有安全泄压装置",{"key":30,"text":105,"correct":32},"机械应急操作装置设置在防护区内",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":30,"analysis":33},933261,"某通信机房，划分为 A、 B、C三个防护区，设置组合分配式七氟丙烷气体灭火系统保护，启动气体采用氮气，下列关于该系统组件的说法中，不正确的是（）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"通向每个防护区的主管道上都应设置压力讯号器",{"key":24,"text":113,"correct":22},"输送氮气的管道宜采用铜管",{"key":27,"text":115,"correct":22},"B防护区选择阀的公称直径应与通向B防护区的主管道的公称直径相等",{"key":30,"text":117,"correct":32},"在集流管和选择阀之间应设置单向阀",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":24,"analysis":33},933262,"下列关于气体灭火系统的灭火机理及适用范围，说法错误的是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"七氟丙烷可用于保护精密仪器设备",{"key":24,"text":125,"correct":32},"IG541 混合气体灭火系统适用于扑救以液体为燃料的火灾",{"key":27,"text":127,"correct":22},"IG541 混合气体灭火属于物理灭火方式",{"key":30,"text":129,"correct":22},"二氧化碳可用于扑救部分固体深位火灾",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":30,"analysis":33},933263,"采用气体灭火系统保护的防护区，两个或两个以上的防护区采用组合分配系统时，一个组合分配系统所保护的防护区不应超过（ ）个。",[134,136,138,140],{"key":20,"text":135,"correct":22},"2",{"key":24,"text":137,"correct":22},"4",{"key":27,"text":139,"correct":22},"6",{"key":30,"text":41,"correct":32},{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":20,"analysis":33},933264,"下列气体灭火系统，可以采用局部应用系统的是（）。",[145,147,149,151],{"key":20,"text":146,"correct":32},"二氧化碳灭火系统",{"key":24,"text":148,"correct":22},"细水雾灭火系统",{"key":27,"text":150,"correct":22},"IG541气体灭火系统",{"key":30,"text":152,"correct":22},"七氟丙烷气体灭火系统",{"id":154,"libraryId":5,"type":155,"typeLabel":156,"stem":157,"options":158,"answer":170,"analysis":33},933265,2,"多选题","下列关于七氟丙烷灭火系统设计的说法中，符合规范要求的有（ ）。",[159,161,163,165,167],{"key":20,"text":160,"correct":22},"用于保护通信机房时，系统设计喷放时间不应大于10s",{"key":24,"text":162,"correct":22},"防护区内包括泄压口在内的开口应在灭火剂喷放前自行关闭",{"key":27,"text":164,"correct":22},"系统不能用于扑救固体表面火灾",{"key":30,"text":166,"correct":32},"系统储存容器的设计与使用应符合国家现行《气瓶安全监察规程》的规定",{"key":168,"text":169,"correct":32},"E","系统设置的机械应急操作装置应设在储瓶间内或防护区疏散出口门外便于操作的地方","DE",{"id":172,"libraryId":5,"type":155,"typeLabel":156,"stem":173,"options":174,"answer":185,"analysis":33},933266,"下列关于气体灭火系统的说法中，正确的是（）。",[175,177,179,181,183],{"key":20,"text":176,"correct":22},"同一防护区设置多台预制灭火装置时，其动作响应时差不应大于5s",{"key":24,"text":178,"correct":32},"对于平时无人工作的防护区，可设置为无延迟的喷射",{"key":27,"text":180,"correct":32},"防护区内外应设手动、自动控制状态的显示装置",{"key":30,"text":182,"correct":32},"采用气体灭火系统的防护区，应设置火灾自动报警系统，并应选用灵敏度级别高的火灾探测器",{"key":168,"text":184,"correct":32},"手动与自动转换装置应设在防护区疏散出口的门外便于操作的地方","BCDE",{"id":187,"libraryId":5,"type":155,"typeLabel":156,"stem":188,"options":189,"answer":200,"analysis":33},933267,"IG—541混合气体灭火剂是由（ ）等气体按一定比例混合而成的气体，从环保角度看，是一种较为理想的灭火剂。",[190,192,194,196,198],{"key":20,"text":191,"correct":32},"二氧化碳",{"key":24,"text":193,"correct":32},"氮气",{"key":27,"text":195,"correct":22},"氦气",{"key":30,"text":197,"correct":22},"氖气",{"key":168,"text":199,"correct":32},"氩气","ABE",{"id":202,"libraryId":5,"type":155,"typeLabel":156,"stem":203,"options":204,"answer":215,"analysis":33},933268,"泡沫灭火系统按发泡倍数分为低倍数泡沫灭火系统、中倍数泡沫灭火系统、高倍数泡沫灭火系统。下列属于中倍数泡沫灭火系统的是（ ）。",[205,207,209,211,213],{"key":20,"text":206,"correct":22},"发泡倍数在10倍的泡沫灭火系统",{"key":24,"text":208,"correct":32},"发泡倍数在30倍的泡沫灭火系统",{"key":27,"text":210,"correct":32},"发泡倍数在50倍的泡沫灭火系统",{"key":30,"text":212,"correct":32},"发泡倍数在100倍的泡沫灭火系统",{"key":168,"text":214,"correct":22},"发泡倍数在300倍的泡沫灭火系统","BCD",{"id":217,"libraryId":5,"type":155,"typeLabel":156,"stem":218,"options":219,"answer":230,"analysis":33},933269,"泡沫灭火系统按系统结构分为（ ）。",[220,222,224,226,228],{"key":20,"text":221,"correct":22},"全淹没式",{"key":24,"text":223,"correct":22},"局部应用式",{"key":27,"text":225,"correct":32},"固定式",{"key":30,"text":227,"correct":32},"半固定式",{"key":168,"text":229,"correct":32},"移动式","CDE",{"id":232,"libraryId":5,"type":155,"typeLabel":156,"stem":233,"options":234,"answer":230,"analysis":33},933270,"泡沫炮灭火系统是一种以泡沫炮为泡沫产生与喷射装置的低倍数泡沫系统。下列场所中，可以使用泡沫炮系统作为主要灭火设施的是（ ）。",[235,237,239,241,243],{"key":20,"text":236,"correct":22},"直径为20m的原油储罐",{"key":24,"text":238,"correct":22},"甲醇储罐区",{"key":27,"text":240,"correct":32},"直径为15m的液化烃储罐",{"key":30,"text":242,"correct":32},"建筑面积为2000m2的飞机库",{"key":168,"text":244,"correct":32},"建筑面积为10000m2的飞机库",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":24,"analysis":33},933271,"下列关于非水溶性液体火灾的说法，错误的是（ ）。",[249,251,253,255],{"key":20,"text":250,"correct":22},"非水溶性液体火灾可以采用液上喷射蛋白泡沫液扑救",{"key":24,"text":252,"correct":32},"非水溶性液体火灾可以采用液下喷射蛋白泡沫液扑救",{"key":27,"text":254,"correct":22},"非水溶性液体火灾可以采用液上喷射氟蛋白泡沫液扑救",{"key":30,"text":256,"correct":22},"非水溶性液体火灾可以采用液下喷射成膜氟蛋白泡沫液扑救",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":30,"analysis":33},933272,"某工厂建有乙醇储罐区，采用泡沫灭火系统保护时，应选用（ ）。",[261,263,265,267],{"key":20,"text":262,"correct":22},"蛋白泡沫液",{"key":24,"text":264,"correct":22},"氟蛋白泡沫液",{"key":27,"text":266,"correct":22},"水成膜泡沫液",{"key":30,"text":268,"correct":32},"抗溶泡沫液",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":27,"analysis":33},933273,"下列储罐火灾可以用半液下喷射方式扑救的是（ ）。",[273,275,277,279],{"key":20,"text":274,"correct":22},"水溶性丙类液体外浮顶储罐火灾",{"key":24,"text":276,"correct":22},"水溶性乙类液体内浮顶储罐火灾",{"key":27,"text":278,"correct":32},"水溶性乙类液体固定顶储罐火灾",{"key":30,"text":280,"correct":22},"非水溶性丙类液体外浮顶储罐火灾",{"id":282,"libraryId":5,"type":15,"typeLabel":16,"stem":283,"options":284,"answer":30,"analysis":33},933274,"固定式泡沫灭火系统的设计应满足在泡沫混合液泵启动后，将泡沫混合液输送到保护对象的时间不大于（ ）min。",[285,286,288,289],{"key":20,"text":135,"correct":22},{"key":24,"text":287,"correct":22},"3",{"key":27,"text":137,"correct":22},{"key":30,"text":39,"correct":32},{"id":291,"libraryId":5,"type":15,"typeLabel":16,"stem":292,"options":293,"answer":20,"analysis":33},933275,"储罐区泡沫灭火系统扑救一次火灾的泡沫混合液设计用量应按（ ）。",[294,296,298,300],{"key":20,"text":295,"correct":32},"罐内用量、该罐辅助泡沫枪用量、管道剩余量三者之和最大的储罐确定",{"key":24,"text":297,"correct":22},"罐内用量、该罐辅助泡沫枪用量、管道剩余量三者之和最小的储罐确定",{"key":27,"text":299,"correct":22},"罐内用量、管道剩余量二者之和最小的储罐确定",{"key":30,"text":301,"correct":22},"罐内用量、管道剩余量二者之和最大的储罐确定",{"id":303,"libraryId":5,"type":15,"typeLabel":16,"stem":304,"options":305,"answer":20,"analysis":33},933276,"某钢制双盘式内浮顶储罐储存有非水溶性液体，储罐采用低倍数泡沫灭火系统进行保护，该泡沫灭火系统的设计保护面积应按（ ）确定。",[306,308,310,312],{"key":20,"text":307,"correct":32},"罐壁与泡沫堰板间的环形面积",{"key":24,"text":309,"correct":22},"储罐外表面积",{"key":27,"text":311,"correct":22},"储罐横截面面积",{"key":30,"text":313,"correct":22},"储罐内表面积",{"id":315,"libraryId":5,"type":15,"typeLabel":16,"stem":316,"options":317,"answer":27,"analysis":33},933277,"当泡沫灭火系统采用环泵式比例混合器时，该比例混合器吸液口不应高于泡沫液储罐最低液面（ ）m。",[318,319,320,322],{"key":20,"text":287,"correct":22},{"key":24,"text":135,"correct":22},{"key":27,"text":321,"correct":32},"1",{"key":30,"text":137,"correct":22},{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":24,"analysis":33},933278,"高背压泡沫产生器是从储罐内底部液下喷射空气泡沫扑救油罐火灾的主要设备。下列属于高背压泡沫产生器发泡倍数范围的是（ ）。",[327,329,331,333],{"key":20,"text":328,"correct":22},"发泡倍数为1倍",{"key":24,"text":330,"correct":32},"发泡倍数为3倍",{"key":27,"text":332,"correct":22},"发泡倍数为5倍",{"key":30,"text":334,"correct":22},"发泡倍数为7倍",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":20,"analysis":33},933279,"泡沫混合液泵应选择特性曲线平缓的离心泵，当采用环泵式比例混合器时，泡沫混合液泵的额定流量应为系统设计流量的（ ）。",[339,341,343,345],{"key":20,"text":340,"correct":32},"1．1倍",{"key":24,"text":342,"correct":22},"1．5倍",{"key":27,"text":344,"correct":22},"2倍",{"key":30,"text":346,"correct":22},"2．5倍",{"id":348,"libraryId":5,"type":15,"typeLabel":16,"stem":349,"options":350,"answer":20,"analysis":33},933280,"下列储罐区适宜采用低倍数液下喷射泡沫灭火系统保护的是（ ）。",[351,353,355,357],{"key":20,"text":352,"correct":32},"非水溶性乙类液体固定顶储罐",{"key":24,"text":354,"correct":22},"水溶性甲类液体外浮顶储罐",{"key":27,"text":356,"correct":22},"水溶性丙类液体内浮顶储罐",{"key":30,"text":358,"correct":22},"非水溶性甲类液体内浮顶储罐",{"id":360,"libraryId":5,"type":15,"typeLabel":16,"stem":361,"options":362,"answer":27,"analysis":33},933281,"泡沫—水喷淋系统保护非水溶性液体时，若采用非吸气型泡沫喷射装置，则下列泡沫可选用的是（ ）。",[363,364,365,366],{"key":20,"text":262,"correct":22},{"key":24,"text":264,"correct":22},{"key":27,"text":266,"correct":32},{"key":30,"text":367,"correct":22},"抗溶性泡沫液",{"id":369,"libraryId":5,"type":15,"typeLabel":16,"stem":370,"options":371,"answer":20,"analysis":33},933282,"下列关于泡沫灭火系统系统选型的说法，不正确的是（ ）。",[372,374,376,378],{"key":20,"text":373,"correct":32},"水溶性乙类液体立式储罐，可以选用泡沫炮作为主要灭火设施",{"key":24,"text":375,"correct":22},"外浮顶和内浮顶储罐应采用液上喷射系统",{"key":27,"text":377,"correct":22},"天然气液化站与接收站的集液池或储罐围堰区可以选用局部应用式高倍数泡沫灭火系统",{"key":30,"text":379,"correct":22},"非水溶性甲类液体固定顶储罐，可以选用液下喷射系统",{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":30,"analysis":33},933283,"泡沫灭火系统的灭火机理不包括（ ）。",[384,386,388,390],{"key":20,"text":385,"correct":22},"隔氧窒息作用",{"key":24,"text":387,"correct":22},"辐射热阻隔作用",{"key":27,"text":389,"correct":22},"吸热冷却作用",{"key":30,"text":391,"correct":32},"乳化作用",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":20,"analysis":33},933284,"当泡沫灭火系统采用（ ）时，泡沫混合液泵的额定流量应为系统设计流量的1．1倍。",[396,398,400,402],{"key":20,"text":397,"correct":32},"环泵式泡沫比例混合器",{"key":24,"text":399,"correct":22},"压力式泡沫比例混合器",{"key":27,"text":401,"correct":22},"平衡压力比例混合器",{"key":30,"text":403,"correct":22},"管线式比例混合器",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":30,"analysis":33},933285,"某罐区采用泡沫灭火系统，下列关于泡沫比例混合器和泡沫产生装置不正确的是（ ）。",[408,410,412,414],{"key":20,"text":409,"correct":22},"环泵式比例混合器适用于规格比较单一的甲乙丙类储罐，并且泡沫比例混合器泡沫液入口不应高于泡沫液最低液面 1m",{"key":24,"text":411,"correct":22},"平衡压力式的比例混合器的泡沫进口压力应大于水的进口压力，压差不应大于 0.2MPa",{"key":27,"text":413,"correct":22},"高背压泡沫产生器本质属于低倍泡沫产生器",{"key":30,"text":415,"correct":32},"中倍泡沫泡沫产生器分固定式和手提式的，固定式目前有 PZ3 和 PZ4，手提式的有 PZ5 和 PZ6",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":20,"analysis":33},933286,"下列叙述哪些是不正确的（ ）。",[420,422,424,426],{"key":20,"text":421,"correct":32},"对于水溶性甲、乙、丙类液体火灾,必须采用液上喷射泡沫方式,且必须选用抗溶性泡沫液",{"key":24,"text":423,"correct":22},"对于非水溶性甲、乙、丙类液体火灾,当采用固定顶储罐时,可以采用液上喷射泡沬方式,也可以采用液下或半液下喷射泡沫方式",{"key":27,"text":425,"correct":22},"对于非水溶性甲、乙、丙类液体火灾,采用液上喷射泡沫方式时,可以选用蛋白、氟蛋白、水成膜或成膜氟蛋白泡沬液",{"key":30,"text":427,"correct":22},"内浮顶储罐和外浮顶储罐不应选用液下喷射泡沫方式",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":24,"analysis":33},933287,"全淹没式高倍数泡沫灭火系统和局部应用式高倍数泡沫灭火系统,自接到火灾信号至开始喷放泡沫的延时不宜超过（ ）。",[432,434,436,438],{"key":20,"text":433,"correct":22},"30s",{"key":24,"text":435,"correct":32},"1min",{"key":27,"text":437,"correct":22},"3min",{"key":30,"text":439,"correct":22},"5min",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":24,"analysis":33},933288,"当用于扑救A类火灾时，高倍数泡沫灭火全淹没系统泡沫淹没深度不应小于最高保护对象高度的（ ）倍。",[444,445,447,449],{"key":20,"text":321,"correct":22},{"key":24,"text":446,"correct":32},"1．1",{"key":27,"text":448,"correct":22},"1．2",{"key":30,"text":89,"correct":22},{"id":451,"libraryId":5,"type":15,"typeLabel":16,"stem":452,"options":453,"answer":20,"analysis":33},933289,"某甲类可燃液体储罐设置固定液上喷射低倍数泡沫灭火器系统，当采用环泵式泡沫比例混合器时，泡沫比例混合器泡沫液入口不应高于泡沫液储罐最低液面（ ）m。",[454,455,457,458],{"key":20,"text":321,"correct":32},{"key":24,"text":456,"correct":22},"0．5",{"key":27,"text":89,"correct":22},{"key":30,"text":459,"correct":22},"0．15",{"id":461,"libraryId":5,"type":15,"typeLabel":16,"stem":462,"options":463,"answer":27,"analysis":33},933290,"对于局部应用系统的高倍数泡沫灭火系统，其高倍数泡沫的供给速率应按达到规定覆盖厚度的时间不应大于（ ）min来确定。",[464,465,466,467],{"key":20,"text":456,"correct":22},{"key":24,"text":321,"correct":22},{"key":27,"text":135,"correct":32},{"key":30,"text":287,"correct":22},{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":30,"analysis":33},933291,"高度大于7m或直径大于（ ）m的固定顶储罐，不得选用泡沫枪作为主要灭火设施。",[472,473,474,476],{"key":20,"text":287,"correct":22},{"key":24,"text":39,"correct":22},{"key":27,"text":475,"correct":22},"7",{"key":30,"text":477,"correct":32},"9",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":24,"analysis":33},933292,"某汽油仓库采用泡沫—水喷雾联用系统，则系统的泡沫供给时间不应小于（ ）min。",[482,483,484,486],{"key":20,"text":39,"correct":22},{"key":24,"text":43,"correct":32},{"key":27,"text":485,"correct":22},"15",{"key":30,"text":487,"correct":22},"20",{"id":489,"libraryId":5,"type":15,"typeLabel":16,"stem":490,"options":491,"answer":24,"analysis":33},933293,"下列不属于泡沫灭火系统灭火机理的是（）。",[492,493,495,496],{"key":20,"text":385,"correct":22},{"key":24,"text":494,"correct":32},"浸湿作用",{"key":27,"text":387,"correct":22},{"key":30,"text":389,"correct":22},{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":20,"analysis":33},933294,"新建一个内浮顶原油储罐，容量为6000m3，采用中倍数泡沫灭火系统时，宜选用（ ）泡沫灭火系统。",[501,503,505,507],{"key":20,"text":502,"correct":32},"固定",{"key":24,"text":504,"correct":22},"移动",{"key":27,"text":506,"correct":22},"半固定",{"key":30,"text":508,"correct":22},"半移动",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":24,"analysis":33},933295,"下列有关泡沫灭火系统型式选择基本要求的说法中，正确的是（ ）。",[513,515,517,519],{"key":20,"text":514,"correct":22},"烃类固定顶储罐不可以采用液下喷射系统",{"key":24,"text":516,"correct":32},"外浮顶和内浮顶储罐应采用液上喷射泡沫系统",{"key":27,"text":518,"correct":22},"水溶性液体的立式储罐可采用泡沫炮作为主要灭火设施",{"key":30,"text":520,"correct":22},"油罐中倍数泡沫系统应选用液下喷射泡沫系统",{"id":522,"libraryId":5,"type":15,"typeLabel":16,"stem":523,"options":524,"answer":27,"analysis":33},933296,"某钢制单盘式内浮顶储罐，储罐直径为 40m，在浮顶上采用泡沫产生器进行保护，至少设置（ ）个泡沫产生器。",[525,526,527,528],{"key":20,"text":135,"correct":22},{"key":24,"text":137,"correct":22},{"key":27,"text":139,"correct":32},{"key":30,"text":41,"correct":22},{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":24,"analysis":33},933297,"高倍数泡沫灭火系统当用于扑救A类火灾时，泡沫淹没深度不应小于最高保护对象高度的（ ）倍。",[533,534,535,536],{"key":20,"text":456,"correct":22},{"key":24,"text":446,"correct":32},{"key":27,"text":135,"correct":22},{"key":30,"text":87,"correct":22},{"id":538,"libraryId":5,"type":15,"typeLabel":16,"stem":539,"options":540,"answer":24,"analysis":33},933298,"当局部应用式高倍数泡沫灭火系统用于扑救B类火灾时，其泡沫连续供给时间不应小于（ ）。",[541,543,545,547],{"key":20,"text":542,"correct":22},"10min",{"key":24,"text":544,"correct":32},"12min",{"key":27,"text":546,"correct":22},"15min",{"key":30,"text":548,"correct":22},"16min",{"id":550,"libraryId":5,"type":15,"typeLabel":16,"stem":551,"options":552,"answer":20,"analysis":33},933299,"某化工厂固定顶油罐采用液下喷射泡沫灭火系统，下列不可以作为备选泡沫液的是（ ）。",[553,554,555,557],{"key":20,"text":262,"correct":32},{"key":24,"text":264,"correct":22},{"key":27,"text":556,"correct":22},"成膜氟蛋白泡沫液",{"key":30,"text":266,"correct":22},{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":30,"analysis":33},933300,"下列选项中，不属于泡沫灭火系统组件的是（ ）。",[562,564,566,568],{"key":20,"text":563,"correct":22},"泡沫液储罐",{"key":24,"text":565,"correct":22},"泡沫比例混合器",{"key":27,"text":567,"correct":22},"泡沫产生装置",{"key":30,"text":569,"correct":32},"水流指示器",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":30,"analysis":33},933301,"泡沫灭火系统由于其保护对象的特性或储罐形式的特殊要求，有多种分类形式。下列属于按系统形式分类的是（ ）。",[574,576,578,580],{"key":20,"text":575,"correct":22},"中倍数泡沫灭火系统",{"key":24,"text":577,"correct":22},"液上喷射系统",{"key":27,"text":579,"correct":22},"固定式系统",{"key":30,"text":581,"correct":32},"全淹没式系统",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":27,"analysis":33},933302,"某储罐区共有5个外浮顶轻柴油储罐，该储罐区应选用的泡沫灭火系统是（ ）。",[586,588,590,592],{"key":20,"text":587,"correct":22},"液上喷射中倍数泡沫灭火系统",{"key":24,"text":589,"correct":22},"液下中倍数泡沫灭火系统",{"key":27,"text":591,"correct":32},"液上低倍数泡沫灭火系统",{"key":30,"text":593,"correct":22},"液下低倍数泡沫灭火系统",{"id":595,"libraryId":5,"type":15,"typeLabel":16,"stem":596,"options":597,"answer":24,"analysis":33},933303,"泡沫灭火系统按系统结构分为固定式、半固定式和移动式，其中移动式系统是（ ）。",[598,600,602,604],{"key":20,"text":599,"correct":22},"由固定的泡沫消防泵、泡沫比例混合器、泡沫产（发）生装置和管道等组成的灭火系统",{"key":24,"text":601,"correct":32},"由消防车、机动消防泵、泡沫比例混合器、移动式泡沫产（发）生装置，用水带连接组成的灭火系统",{"key":27,"text":603,"correct":22},"泡沫从储罐底部注入，并通过软管浮升到液体燃料表面进行灭火的泡沫灭火系统",{"key":30,"text":605,"correct":22},"由固定的泡沫产生装置及部分连接管道、泡沫消防车或机动泵，用水带连接组成的灭火系统",[607,610,613,616,619,622],{"id":15,"name":608,"category":7,"favorite":609},"领导干部任职前廉政法规知识测试题",92,{"id":611,"name":612,"category":7,"favorite":15},595,"建筑结构与设备",{"id":614,"name":615,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":617,"name":618,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":620,"name":621,"category":7,"favorite":8},534,"BIM工程师",{"id":623,"name":621,"category":7,"favorite":8},535]