[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-31":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":621},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,31,50,2960,[13,34,46,58,70,81,93,105,117,129,141,152,170,185,200,215,230,245,260,275,290,304,318,330,340,352,364,373,385,397,409,417,429,441,453,462,474,486,495,507,517,525,536,548,557,565,577,589,601,613],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},933204,1,"单选题","闭式细水雾灭火系统的作用面积不宜小于（）m2，每套泵组所带喷头数量不应超过（）只。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","260，500",false,{"key":24,"text":25,"correct":26},"B","140，100",true,{"key":28,"text":29,"correct":22},"C","160，500",{"key":31,"text":32,"correct":22},"D","160，100","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},933205,"细水雾灭火系统的设计应当综合考虑保护对象的火灾危险性及其火灾特性、防护目标和环境条件等因素，合理的选择适当的类型。以下关于细水雾灭火系统的选择错误的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"某采用非密集柜储存的图书馆采用闭式系统",{"key":24,"text":41,"correct":26},"某柴油机发电房采用局部应用方式的闭式系统",{"key":28,"text":43,"correct":22},"某配电室采用全淹没的开式细水雾灭火系统",{"key":31,"text":45,"correct":22},"某油浸变压器室采用局部应用的开式系统",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},933206,"在细水雾灭火系统中，按雾化介质划分的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"双流体系统",{"key":24,"text":53,"correct":22},"泵组式系统",{"key":28,"text":55,"correct":22},"瓶组式系统",{"key":31,"text":57,"correct":22},"瓶组与泵组结合式系统",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},933207,"下列关于细水雾系统成雾原理的说法中，属于双流体异管系统射流成雾原理的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"液体以很高的速度被释放出来，由于液体与周围空气的速度差而被撕碎成为细水雾",{"key":24,"text":65,"correct":22},"两股成分类似的液体射流相互碰撞，将液体射流打散成细水雾",{"key":28,"text":67,"correct":22},"液体在压力容器中被加热到高于沸点，突然被释放到大气压力状态形成细水雾",{"key":31,"text":69,"correct":26},"由一套管道向喷头提供灭火介质，另外一套管道提供雾化介质，两种在分离管道系统中传输的物质在喷头处混合后相互碰撞，从而产生细水雾",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},933208,"细水雾灭火系统主要按工作压力、应用方式、动作方式、雾化介质和供水方式进行分类，下列属于按应用方式分类的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"中压系统",{"key":24,"text":77,"correct":26},"全淹没式系统",{"key":28,"text":79,"correct":22},"开式系统",{"key":31,"text":53,"correct":22},{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":24,"analysis":33},933209,"细水雾灭火系统按照动作方式可以分为闭式系统和开式系统，其中开式细水雾灭火系统包括（ ）。",[85,87,89,91],{"key":20,"text":86,"correct":22},"湿式、干式和预作用三种形式",{"key":24,"text":88,"correct":26},"全淹没应用方式、局部应用方式",{"key":28,"text":90,"correct":22},"单元独立系统、组合分配系统",{"key":31,"text":92,"correct":22},"管网灭火系统、无管网灭火系统",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":31,"analysis":33},933210,"下列火灾中，适合采用细水雾灭火系统进行扑救的是（ ）。",[97,99,101,103],{"key":20,"text":98,"correct":22},"液化天然气火灾",{"key":24,"text":100,"correct":22},"可燃固体深位火灾",{"key":28,"text":102,"correct":22},"碳化钙火灾",{"key":31,"text":104,"correct":26},"可燃液体火灾",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":28,"analysis":33},933211,"当细水雾灭火系统设置在有爆炸危险的环境中时，其管网和组件应采取（ ）措施。",[109,111,113,115],{"key":20,"text":110,"correct":22},"泄压",{"key":24,"text":112,"correct":22},"干式除尘",{"key":28,"text":114,"correct":26},"静电导除",{"key":31,"text":116,"correct":22},"防爆除尘",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":28,"analysis":33},933212,"采用全淹没应用方式的瓶组式细水雾灭火系统，当同一防护区内采用多组瓶组时，各瓶组必须能同时启动，其动作响应时差不应大于（ ）s。",[121,123,125,127],{"key":20,"text":122,"correct":22},"5",{"key":24,"text":124,"correct":22},"15",{"key":28,"text":126,"correct":26},"2",{"key":31,"text":128,"correct":22},"30",{"id":130,"libraryId":5,"type":15,"typeLabel":16,"stem":131,"options":132,"answer":28,"analysis":33},933213,"高压细水雾灭火系统的控制阀组通常采用（ ）。",[133,135,137,139],{"key":20,"text":134,"correct":22},"雨淋阀",{"key":24,"text":136,"correct":22},"选择阀",{"key":28,"text":138,"correct":26},"分配阀",{"key":31,"text":140,"correct":22},"湿式报警阀组",{"id":142,"libraryId":5,"type":15,"typeLabel":16,"stem":143,"options":144,"answer":20,"analysis":33},933214,"细水雾灭火系统的闭式喷头的公称动作温度宜高于环境最高温度（ ）℃。",[145,146,148,150],{"key":20,"text":128,"correct":26},{"key":24,"text":147,"correct":22},"40",{"key":28,"text":149,"correct":22},"50",{"key":31,"text":151,"correct":22},"60",{"id":153,"libraryId":5,"type":154,"typeLabel":155,"stem":156,"options":157,"answer":169,"analysis":33},933215,2,"多选题","下列场所或建筑采用开式细水雾灭火系统保护时，宜采用局部应用方式的开式系统的有（ ）。",[158,160,162,164,166],{"key":20,"text":159,"correct":26},"柴油发电机房",{"key":24,"text":161,"correct":26},"油浸变压器室",{"key":28,"text":163,"correct":26},"润滑油站",{"key":31,"text":165,"correct":22},"配电室",{"key":167,"text":168,"correct":22},"E","液压站","ABC",{"id":171,"libraryId":5,"type":154,"typeLabel":155,"stem":172,"options":173,"answer":184,"analysis":33},933216,"下列关于细水雾灭火系统控制的说法中，错误的是（ ）。",[174,176,178,180,182],{"key":20,"text":175,"correct":26},"在消防控制室入口处和防护区内，应设置系统手动启动装置",{"key":24,"text":177,"correct":22},"瓶组系统应具有自动、手动和机械应急操作控制方式",{"key":28,"text":179,"correct":26},"泵组系统应具有自动、手动和机械应急操作控制方式",{"key":31,"text":181,"correct":22},"手动启动装置和机械应急操作装置应能在一处完成系统启动的全部操作",{"key":167,"text":183,"correct":22},"闭式系统的自动控制应能在喷头动作后，由动作信号反馈装置直接联锁自动启动","AC",{"id":186,"libraryId":5,"type":154,"typeLabel":155,"stem":187,"options":188,"answer":199,"analysis":33},933217,"下列物质中，可以采用二氧化碳灭火系统进行扑救的有（ ）。",[189,191,193,195,197],{"key":20,"text":190,"correct":26},"石蜡",{"key":24,"text":192,"correct":22},"硝化纤维",{"key":28,"text":194,"correct":26},"沥青",{"key":31,"text":196,"correct":26},"煤油",{"key":167,"text":198,"correct":22},"氢化钾","ACD",{"id":201,"libraryId":5,"type":154,"typeLabel":155,"stem":202,"options":203,"answer":214,"analysis":33},933218,"某防护区采用全淹没式七氟丙烷灭火系统保护，室内净高4m，下列关于该防护区的做法，不符合规定的有（ ）。",[204,206,208,210,212],{"key":20,"text":205,"correct":26},"防护区门窗耐火极限为0．25h",{"key":24,"text":207,"correct":22},"防护区吊顶耐火极限为0．5h",{"key":28,"text":209,"correct":22},"防护区泄压口高度为2．8m",{"key":31,"text":211,"correct":22},"防护区最低温度为4℃",{"key":167,"text":213,"correct":26},"防护区围护结构能够承受的压强为1100Pa","AE",{"id":216,"libraryId":5,"type":154,"typeLabel":155,"stem":217,"options":218,"answer":229,"analysis":33},933219,"某防护区平时有人工作，采用全淹没式二氧化碳气体灭火系统保护，下列关于该系统控制与操作的说法中，错误的有（ ）。",[219,221,223,225,227],{"key":20,"text":220,"correct":22},"当采用火灾探测器时，灭火系统的自动控制应在接收到两个独立的火灾信号后才能启动",{"key":24,"text":222,"correct":22},"系统宜延迟启动，但延迟时间不应大于30s",{"key":28,"text":224,"correct":26},"手动操作装置应设在防护区内便于操作的地方",{"key":31,"text":226,"correct":22},"防护区入口处应设置手动、自动转换控制装置",{"key":167,"text":228,"correct":26},"手动、自动转换控制应置于自动控制状态","CE",{"id":231,"libraryId":5,"type":154,"typeLabel":155,"stem":232,"options":233,"answer":244,"analysis":33},933220,"某场所设置在建筑的地下一层，采用IG541气体灭火系统保护，下列关于该气体灭火系统安全要求的说法，符合规范要求的有（ ）。",[234,236,238,240,242],{"key":20,"text":235,"correct":26},"防护区应有保证人员在30s内疏散完毕的通道和出口",{"key":24,"text":237,"correct":26},"防护区内应设置火灾声警报器",{"key":28,"text":239,"correct":22},"防护区的入口处应设置灭火剂释放指示灯，指示灯信号在灭火剂释放完毕后自动消除",{"key":31,"text":241,"correct":26},"防护区内应设置机械排风装置",{"key":167,"text":243,"correct":26},"防护区用于疏散的门必须能从防护区内打开","ABDE",{"id":246,"libraryId":5,"type":154,"typeLabel":155,"stem":247,"options":248,"answer":259,"analysis":33},933221,"下列有关IG541气体灭火系统储存装置的说法中，正确的有（ ）。",[249,251,253,255,257],{"key":20,"text":250,"correct":26},"IG541预制灭火系统的储存装置没有集流管",{"key":24,"text":252,"correct":26},"IG541管网灭火系统的储存装置宜设置在专用的储瓶间内",{"key":28,"text":254,"correct":26},"储存装置的公称工作压力，不应小于在最高环境温度下所承受的工作压力",{"key":31,"text":256,"correct":26},"储存装置上应设耐久的固定铭牌，并应标明每个容器的编号、容积、皮重、灭火剂名称等",{"key":167,"text":258,"correct":22},"储存装置应设置在阳光充足的地方","ABCD",{"id":261,"libraryId":5,"type":154,"typeLabel":155,"stem":262,"options":263,"answer":274,"analysis":33},933222,"对于组合分配二氧化碳灭火系统而言，在下列哪些情况下要设置备用量（ ）。",[264,266,268,270,272],{"key":20,"text":265,"correct":26},"保护5个防护区",{"key":24,"text":267,"correct":22},"保护3个防护区",{"key":28,"text":269,"correct":26},"保护6个防护区",{"key":31,"text":271,"correct":26},"72h内不能恢复",{"key":167,"text":273,"correct":26},"48h内不能恢复","ACDE",{"id":276,"libraryId":5,"type":154,"typeLabel":155,"stem":277,"options":278,"answer":289,"analysis":33},933223,"气体灭火系统根据其灭火剂种类、灭火机理不同，其适用范围也各不相同，下列火灾中，用二氧化碳灭火系统和七氟丙烷灭火系统均可扑灭的有（ ）。",[279,281,283,285,287],{"key":20,"text":280,"correct":26},"灭火前可切断气源的气体火灾",{"key":24,"text":282,"correct":26},"电气火灾",{"key":28,"text":284,"correct":22},"金属火灾",{"key":31,"text":286,"correct":26},"固体表面火灾",{"key":167,"text":288,"correct":22},"棉毛、织物、纸张等部分固体深位火灾","ABD",{"id":291,"libraryId":5,"type":154,"typeLabel":155,"stem":292,"options":293,"answer":303,"analysis":33},933224,"二氧化碳灭火系统是以二氧化碳作为灭火介质的气体灭火系统，下列火灾中，不可以采用二氧化碳气体灭火系统进行扑救的是（ ）。",[294,295,297,299,301],{"key":20,"text":282,"correct":22},{"key":24,"text":296,"correct":26},"活泼金属火灾",{"key":28,"text":298,"correct":26},"金属氢化物火灾",{"key":31,"text":300,"correct":22},"石蜡火灾",{"key":167,"text":302,"correct":26},"不可能切断气源的气体火灾","BCE",{"id":305,"libraryId":5,"type":154,"typeLabel":155,"stem":306,"options":307,"answer":259,"analysis":33},933225,"某地铁车站设有高压二氧化碳气体灭火系统，该系统共保护3个防护区域，下列关于该系统消防设计的说法中，正确的是（）。",[308,310,312,314,316],{"key":20,"text":309,"correct":26},"系统应设有自动控制、手动控制和机械应急操作三种启动方式",{"key":24,"text":311,"correct":26},"根据人员疏散要求，系统宜延迟启动，但延迟时间不应大于30s",{"key":28,"text":313,"correct":26},"手动操作装置应设在防护区外便于操作的地方",{"key":31,"text":315,"correct":26},"系统的动作信号及相关警报信号、工作状态和控制状态均应能在火灾报警控制器上显示",{"key":167,"text":317,"correct":22},"系统应设有自动控制和机械应急操作两种启动方式",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":24,"analysis":33},933226,"某建筑设有IG-541组合分配灭火系统，则该系统所保护的防护区不应超过（ ）个。",[322,324,326,328],{"key":20,"text":323,"correct":22},"6",{"key":24,"text":325,"correct":26},"8",{"key":28,"text":327,"correct":22},"10",{"key":31,"text":329,"correct":22},"12",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":20,"analysis":33},933227,"某4层电子信息机房，层高4m，每层面积为1600m2，设置七氟丙烷预制灭火系统保护，则该建筑的防护区最少划分为（ ）个。",[334,336,337,339],{"key":20,"text":335,"correct":26},"16",{"key":24,"text":325,"correct":22},{"key":28,"text":338,"correct":22},"20",{"key":31,"text":329,"correct":22},{"id":341,"libraryId":5,"type":15,"typeLabel":16,"stem":342,"options":343,"answer":20,"analysis":33},933228,"某场所划分为一个防护区，防护区内设置多台七氟丙烷预制灭火装置保护，下列关于该系统的说法，不正确的是（ ）。",[344,346,348,350],{"key":20,"text":345,"correct":26},"不宜设置10台及以上预制灭火装置",{"key":24,"text":347,"correct":22},"预制灭火装置必须能同时启动，动作响应时差不得大于2s",{"key":28,"text":349,"correct":22},"防护区内应设置泄压口，泄压口高度应位于防护区净高2／3以上",{"key":31,"text":351,"correct":22},"应设置自动控制和手动控制两种启动方式",{"id":353,"libraryId":5,"type":15,"typeLabel":16,"stem":354,"options":355,"answer":24,"analysis":33},933229,"下列关于气体灭火系统设计的说法中，错误的是（ ）。",[356,358,360,362],{"key":20,"text":357,"correct":22},"管网上不应采用四通管件进行分流",{"key":24,"text":359,"correct":26},"同一防护区，当设计两套或三套管网时，系统启动装置可分别设置",{"key":28,"text":361,"correct":22},"同一集流管上的储存容器，其规格、充压压力和充装量应相同",{"key":31,"text":363,"correct":22},"灭火系统的灭火剂储存量，应为防护区设计用量与储存容器的剩余量和管网内的剩余量之和",{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":28,"analysis":33},933230,"某通讯机房采用七氟丙烷灭火系统保护时，设计喷放时间不应大于（ ）s。",[368,370,371,372],{"key":20,"text":369,"correct":22},"4",{"key":24,"text":323,"correct":22},{"key":28,"text":325,"correct":26},{"key":31,"text":327,"correct":22},{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":28,"analysis":33},933231,"某防护区内设有IG-541预制灭火系统，该系统的充装压力不应大于（ ）。",[377,379,381,383],{"key":20,"text":378,"correct":22},"1．2MPa",{"key":24,"text":380,"correct":22},"2．4MPa",{"key":28,"text":382,"correct":26},"2．5MPa",{"key":31,"text":384,"correct":22},"3．6MPa",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":24,"analysis":33},933232,"下列关于气体灭火系统操作与控制的说法，错误的是（ ）。",[389,391,393,395],{"key":20,"text":390,"correct":22},"气体灭火系统的电源，应符合现行国家有关消防技术标准的规定",{"key":24,"text":392,"correct":26},"组合分配系统启动时，选择阀应在容器阀开启后打开",{"key":28,"text":394,"correct":22},"气体灭火系统的操作与控制，应包括对开口封闭装置、通风机械和防火阀等设备的联动操作与控制",{"key":31,"text":396,"correct":22},"设有消防控制室的场所，各防护区灭火控制系统的有关信息应传送给消防控制室",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":28,"analysis":33},933233,"某油浸式电力变压器室，设置了局部应用式二氧化碳气体灭火系统保护，下列有关该系统在设计时应注意问题的说法中，不正确的是（ ）。",[401,403,405,407],{"key":20,"text":402,"correct":22},"确保保护对象周围空气流动速度不宜大于3m／s",{"key":24,"text":404,"correct":22},"确保喷头与保护对象之间，喷头喷射角范围内不应有遮挡物",{"key":28,"text":406,"correct":26},"确保油浸式电力变压器室的外墙上应设置泄压口",{"key":31,"text":408,"correct":22},"确保手动操作装置应设置在保护对象附近",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":28,"analysis":33},933234,"某电子计算机房划分为一个防护区，防护区内设置七氟丙烷灭火系统，该系统的设计喷放时间不应大于（ ）s。",[413,414,415,416],{"key":20,"text":323,"correct":22},{"key":24,"text":327,"correct":22},{"key":28,"text":325,"correct":26},{"key":31,"text":329,"correct":22},{"id":418,"libraryId":5,"type":15,"typeLabel":16,"stem":419,"options":420,"answer":28,"analysis":33},933235,"下列关于二氧化碳气体灭火系统的说法，错误的是（ ）。",[421,423,425,427],{"key":20,"text":422,"correct":22},"启动释放二氧化碳之前或同时，必须切断可燃、助燃气体的气源",{"key":24,"text":424,"correct":22},"组合分配系统的二氧化碳储存量，不应小于所需储存量最大一个防护区的储存量",{"key":28,"text":426,"correct":26},"组合分配系统保护8个及以上的防护区或保护对象时，二氧化碳应有备用量",{"key":31,"text":428,"correct":22},"组合分配系统储存量48h内不能恢复时，二氧化碳应有备用量",{"id":430,"libraryId":5,"type":15,"typeLabel":16,"stem":431,"options":432,"answer":28,"analysis":33},933236,"某建筑内通信机房设置二氧化碳气体灭火系统保护，二氧化碳气体灭火系统设有专用的储存容器间，该储存容器间内设有机械排风装置。下列关于储存容器间的做法，不符合规定的是（ ）。",[433,435,437,439],{"key":20,"text":434,"correct":22},"储存容器间靠近防护区，出口直接通向室外",{"key":24,"text":436,"correct":22},"储存容器间室内干燥",{"key":28,"text":438,"correct":26},"机械排风装置的排风口距储存容器间地面高度为0．6m",{"key":31,"text":440,"correct":22},"储存容器间耐火等级为二级",{"id":442,"libraryId":5,"type":15,"typeLabel":16,"stem":443,"options":444,"answer":20,"analysis":33},933237,"适用于局部应用系统的灭火系统有（ ）。",[445,447,449,451],{"key":20,"text":446,"correct":26},"二氧化碳灭火系统",{"key":24,"text":448,"correct":22},"七氟丙烷灭火系统",{"key":28,"text":450,"correct":22},"IG541 灭火系统",{"key":31,"text":452,"correct":22},"热气溶胶灭火系统",{"id":454,"libraryId":5,"type":15,"typeLabel":16,"stem":455,"options":456,"answer":20,"analysis":33},933238,"气体灭火系统不适用于扑救（ ）火灾。",[457,458,459,461],{"key":20,"text":198,"correct":26},{"key":24,"text":282,"correct":22},{"key":28,"text":460,"correct":22},"液体火灾",{"key":31,"text":286,"correct":22},{"id":463,"libraryId":5,"type":15,"typeLabel":16,"stem":464,"options":465,"answer":28,"analysis":33},933239,"IG—541混合气体灭火系统的灭火设计浓度不应小于灭火浓度的（ ）倍。",[466,468,470,472],{"key":20,"text":467,"correct":22},"1．1",{"key":24,"text":469,"correct":22},"1．2",{"key":28,"text":471,"correct":26},"1．3",{"key":31,"text":473,"correct":22},"1．5",{"id":475,"libraryId":5,"type":15,"typeLabel":16,"stem":476,"options":477,"answer":24,"analysis":33},933240,"气体灭火系统防护区的划分应根据封闭空间的结构特点和位置来划分，其中，采用预制灭火系统时，一个防护区的面积不宜大于（ ）m2。",[478,480,482,484],{"key":20,"text":479,"correct":22},"300",{"key":24,"text":481,"correct":26},"500",{"key":28,"text":483,"correct":22},"800",{"key":31,"text":485,"correct":22},"1600",{"id":487,"libraryId":5,"type":15,"typeLabel":16,"stem":488,"options":489,"answer":24,"analysis":33},933241,"七氟丙烷灭火系统的灭火设计浓度不应小于灭火浓度的（ ）倍。",[490,491,492,493],{"key":20,"text":467,"correct":22},{"key":24,"text":471,"correct":26},{"key":28,"text":473,"correct":22},{"key":31,"text":494,"correct":22},"1．7",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":28,"analysis":33},933242,"某高层公共建筑地下一层设有低压配电间，拟采用IG—541气体灭火系统保护。配电间旁边设置有气体储瓶间。以下说法错误的是（ ）。",[499,501,503,505],{"key":20,"text":500,"correct":22},"低压配电间的气体管道应设置防静电接地",{"key":24,"text":502,"correct":22},"储瓶间内应设应急照明",{"key":28,"text":504,"correct":26},"配电间应设置机械排风装置，排风口宜设在防护区的上部并应直通室外",{"key":31,"text":506,"correct":22},"地下储瓶间应设机械排风装置，排风口应设在下部，可通过排风管排出室外",{"id":508,"libraryId":5,"type":15,"typeLabel":16,"stem":509,"options":510,"answer":31,"analysis":33},933243,"某4层电子计算机房，每层有建筑面积1000m2计算机房2个、建筑面积为100m2的小计算机房4个，层高均为4m，均设置组合分配七氟丙烷气体灭火系统保护，则至少需要设置（ ）套组合分配系统。",[511,513,514,516],{"key":20,"text":512,"correct":22},"1",{"key":24,"text":126,"correct":22},{"key":28,"text":515,"correct":22},"3",{"key":31,"text":369,"correct":26},{"id":518,"libraryId":5,"type":15,"typeLabel":16,"stem":519,"options":520,"answer":28,"analysis":33},933244,"某电子计算机房设置了七氟丙烷管网灭火系统，该系统的应有（）种启动方式。",[521,522,523,524],{"key":20,"text":512,"correct":22},{"key":24,"text":126,"correct":22},{"key":28,"text":515,"correct":26},{"key":31,"text":369,"correct":22},{"id":526,"libraryId":5,"type":15,"typeLabel":16,"stem":527,"options":528,"answer":28,"analysis":33},933245,"下列（）属于二氧化碳灭火系统不能扑救的火灾。",[529,531,532,534],{"key":20,"text":530,"correct":22},"沥青火灾",{"key":24,"text":286,"correct":22},{"key":28,"text":533,"correct":26},"氢化钾火灾",{"key":31,"text":535,"correct":22},"织物深位火灾",{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":20,"analysis":33},933246,"根据《气体灭火系统设计规范》（GB 50370-2005），下列关于气体灭火系统选用的说法中，错误的是（ ）。",[540,542,544,546],{"key":20,"text":541,"correct":26},"气体灭火适用于扑救电气火灾、固体火灾和液体火灾",{"key":24,"text":543,"correct":22},"IG541混合气体灭火系统一般不提倡用于扑救主燃料为液体的火灾",{"key":28,"text":545,"correct":22},"热气溶胶预制灭火系统不应设置在酒店大堂中",{"key":31,"text":547,"correct":22},"灭火前能切断气源的气体火灾可采用气体灭火系统扑救",{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":550,"options":551,"answer":28,"analysis":33},933247,"采用管网灭火系统时，一个防护区的面积不宜大于（ ）m2，且容积不宜大于3600m3。",[552,553,554,555],{"key":20,"text":479,"correct":22},{"key":24,"text":481,"correct":22},{"key":28,"text":483,"correct":26},{"key":31,"text":556,"correct":22},"1000",{"id":558,"libraryId":5,"type":15,"typeLabel":16,"stem":559,"options":560,"answer":31,"analysis":33},933248,"全淹没二氧化碳灭火系统中的二氧化碳设计浓度不应小于灭火浓度的（ ）倍，并不得低于34％。",[561,562,563,564],{"key":20,"text":512,"correct":22},{"key":24,"text":471,"correct":22},{"key":28,"text":473,"correct":22},{"key":31,"text":494,"correct":26},{"id":566,"libraryId":5,"type":15,"typeLabel":16,"stem":567,"options":568,"answer":28,"analysis":33},933249,"某场所划分为一个防护区，防护区设置三套管网式IG541气体灭火系统保护，下列关于该系统的说法，不正确的是（ ）。",[569,571,573,575],{"key":20,"text":570,"correct":22},"三套系统的集流管可以分别设置",{"key":24,"text":572,"correct":22},"三套系统的启动装置必须共用",{"key":28,"text":574,"correct":26},"三套管网上喷头的流量可按不同灭火设计浓度设计",{"key":31,"text":576,"correct":22},"三套管网上喷头的流量应按同一喷放时间进行设计",{"id":578,"libraryId":5,"type":15,"typeLabel":16,"stem":579,"options":580,"answer":31,"analysis":33},933250,"下列关于低压二氧化碳灭火系统的说法中，不正确的是（）。",[581,583,585,587],{"key":20,"text":582,"correct":22},"储存容器的设计压力不应小于2．5MPa",{"key":24,"text":584,"correct":22},"储存容器上至少应设置两套安全泄压装置",{"key":28,"text":586,"correct":22},"储存装置的高压报警压力设定值应为2．2MPa",{"key":31,"text":588,"correct":26},"储存装置应远离热源，位置应便于再充装，其环境温度宜为0℃～49％",{"id":590,"libraryId":5,"type":15,"typeLabel":16,"stem":591,"options":592,"answer":31,"analysis":33},933251,"根据《气体灭火系统设计规范》GB50370—2005的规定，下列关于气体灭火系统的说法中，不正确的是（）。",[593,595,597,599],{"key":20,"text":594,"correct":22},"两个或两个以上的防护区采用组合分配系统时，一个组合分配系统所保护的防护区不应超过8个",{"key":24,"text":596,"correct":22},"七氟丙烷灭火系统的储存装置72小时内不能重新充装恢复工作的，应按系统原储存量的100％设置备用量",{"key":28,"text":598,"correct":22},"当IG541混合气体灭火剂喷放至设计用量的95％时，其喷放时间不应大于60s，且不应小于48s",{"key":31,"text":600,"correct":26},"七氟丙烷灭火系统用于保护电子计算机房时，其设计喷放时间不应大于10s",{"id":602,"libraryId":5,"type":15,"typeLabel":16,"stem":603,"options":604,"answer":24,"analysis":33},933252,"IG541气体灭火系统是以IG541混合气体灭火剂作为灭火介质的气体灭火系统，下列有关IG541气体的说法，不正确的是（ ）。",[605,607,609,611],{"key":20,"text":606,"correct":22},"IG541混合气体灭火剂是由氮气、氩气和二氧化碳气体按一定比例混合而成的气体",{"key":24,"text":608,"correct":26},"IG541混合气体灭火剂属于化学灭火剂",{"key":28,"text":610,"correct":22},"IG541混合气体具有无毒、无色、无味、无腐蚀性及不支持燃烧、不导电的特性",{"key":31,"text":612,"correct":22},"IG541混合气体以环保的角度来看，是一种较为理想的灭火剂",{"id":614,"libraryId":5,"type":15,"typeLabel":16,"stem":615,"options":616,"answer":28,"analysis":33},933253,"某电子信息机房设置二氧化碳灭火系统全保护，该系统应有（ ）种启动方式。",[617,618,619,620],{"key":20,"text":512,"correct":22},{"key":24,"text":126,"correct":22},{"key":28,"text":515,"correct":26},{"key":31,"text":369,"correct":22},[622,625,628,631,634,637],{"id":15,"name":623,"category":7,"favorite":624},"领导干部任职前廉政法规知识测试题",92,{"id":626,"name":627,"category":7,"favorite":15},595,"建筑结构与设备",{"id":629,"name":630,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":632,"name":633,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":635,"name":636,"category":7,"favorite":8},534,"BIM工程师",{"id":638,"name":636,"category":7,"favorite":8},535]