[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-30":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":588},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,30,50,2960,[13,34,46,58,70,82,94,106,118,130,142,153,163,175,187,199,208,220,231,243,255,266,274,286,296,308,316,324,333,344,353,364,372,387,402,413,428,440,452,464,473,485,497,509,520,532,544,552,564,576],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},933154,1,"单选题","某厂房内设有水喷雾灭火系统，当系统响应时间为125s时，该系统应至少有（ ）种控制方式。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","1",false,{"key":24,"text":25,"correct":26},"B","2",true,{"key":28,"text":29,"correct":22},"C","3",{"key":31,"text":32,"correct":22},"D","4","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},933155,"下列关于水喷雾灭火系统喷头设置的说法，错误的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"水喷雾灭火系统保护卧式储罐时，水雾喷头的布置应使水雾完全覆盖裸露表面，罐体液位计、阀门等处也应设水雾喷头保护",{"key":24,"text":41,"correct":22},"水喷雾灭火系统保护电缆时，水雾喷头的布置应使水雾完全包围电缆",{"key":28,"text":43,"correct":26},"水喷雾灭火系统保护燃油锅炉时，宜布置在保护对象的底部周围",{"key":31,"text":45,"correct":22},"水喷雾灭火系统保护输送机皮带时，水雾喷头的布置应使水雾完全包络着火输送机的机头、机尾和上行皮带上表面",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},933156,"下列关于水喷雾灭火系统中水雾喷头的说法中，正确的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"扑救电气火灾，应选用撞击型水雾喷头",{"key":24,"text":53,"correct":26},"离心雾化型水雾喷头应带柱状过滤网",{"key":28,"text":55,"correct":22},"室内粉尘场所设置的水雾喷头宜带防尘帽，室外设置的水雾喷头应带防尘帽",{"key":31,"text":57,"correct":22},"保护对象为油浸式电力变压器时，水雾喷头之间的水平距离与垂直距离无需满足水雾锥相交的要求",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},933157,"水喷雾灭火系统给水管道的工作压力不应大于（ ）MPa。",[62,64,66,68],{"key":20,"text":63,"correct":22},"1．0",{"key":24,"text":65,"correct":22},"1．2",{"key":28,"text":67,"correct":22},"1．4",{"key":31,"text":69,"correct":26},"1．6",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":31,"analysis":33},933158,"水喷雾灭火系统以灭火为目的时，不适用的火灾类型是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"固体火灾",{"key":24,"text":77,"correct":22},"丙类液体火灾",{"key":28,"text":79,"correct":22},"电气火灾",{"key":31,"text":81,"correct":26},"气体火灾",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},933159,"下列选项中，属于电动启动水喷雾灭火系统的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":26},"系统利用感烟火灾探测器探测火灾",{"key":24,"text":89,"correct":22},"系统利用闭式喷头探测火灾",{"key":28,"text":91,"correct":22},"雨淋阀通过充液传动管开启",{"key":31,"text":93,"correct":22},"雨淋阀通过充气传动管开启",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":20,"analysis":33},933160,"响应时间是指由火灾报警设备发出信号至系统中最不利点水雾喷头喷出水雾的时间。用于灭火目的时，系统的响应时间不应大于（ ）s。",[98,100,102,104],{"key":20,"text":99,"correct":26},"60",{"key":24,"text":101,"correct":22},"120",{"key":28,"text":103,"correct":22},"250",{"key":31,"text":105,"correct":22},"300",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":24,"analysis":33},933161,"直通雨淋阀与角式雨淋阀相比，其突出的优点是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"功能完善",{"key":24,"text":113,"correct":26},"水力摩阻损失小",{"key":28,"text":115,"correct":22},"耐蚀性好",{"key":31,"text":117,"correct":22},"维护方便",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":28,"analysis":33},933162,"某柴油发电机采用水喷雾灭火系统进行保护，水雾喷头距离柴油发电机的距离为1m，雾化角为120 度，菱形布置水雾喷头，则应该选取（ ）类型的喷头，喷头间距（ ）m。",[122,124,126,128],{"key":20,"text":123,"correct":22},"撞击，2.9",{"key":24,"text":125,"correct":22},"离心雾化，3",{"key":28,"text":127,"correct":26},"离心雾化，2.9",{"key":31,"text":129,"correct":22},"撞击，3",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},933163,"下列关于水喷雾灭火系统保护对象的保护面积说法错误的是（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"当保护对象外形不规则时，应按包容保护对象的最小规则形体的外表面面积确定",{"key":24,"text":137,"correct":26},"分层敷设的电缆的保护面积应按整体包容电缆的最大规则形体的外表面面积确定",{"key":28,"text":139,"correct":22},"变压器的保护面积除应按扣除底面面积以外的变压器油箱外表面面积确定外，还应包括散热器的外表面面积和油枕及集油坑的投影面积",{"key":31,"text":141,"correct":22},"输送机皮带的保护面积应按上行皮带的上表面面积确定",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":24,"analysis":33},933164,"某火力发电厂输煤栈桥输送皮带总长550m，采用水喷雾灭火系统保护时，该输煤栈桥最多可划分为（ ）段分段进行保护。",[146,147,149,151],{"key":20,"text":32,"correct":22},{"key":24,"text":148,"correct":26},"5",{"key":28,"text":150,"correct":22},"6",{"key":31,"text":152,"correct":22},"7",{"id":154,"libraryId":5,"type":15,"typeLabel":16,"stem":155,"options":156,"answer":20,"analysis":33},933165,"雨淋阀组宜设在环境温度不低于（ ）℃且不高于70℃，并有排水设施的室内，其位置宜靠近保护对象并便于操作。",[157,158,159,161],{"key":20,"text":32,"correct":26},{"key":24,"text":148,"correct":22},{"key":28,"text":160,"correct":22},"10",{"key":31,"text":162,"correct":22},"30",{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":165,"options":166,"answer":31,"analysis":33},933166,"传动管启动水喷雾灭火系统比较适用于下列场所（）。",[167,169,171,173],{"key":20,"text":168,"correct":22},"冰冻场所",{"key":24,"text":170,"correct":22},"高危场所",{"key":28,"text":172,"correct":22},"安装有普通火灾探测器的场所",{"key":31,"text":174,"correct":26},"不适合安装普通火灾探测器的场所",{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":24,"analysis":33},933167,"水喷雾灭火系统的水雾喷头使水从连续的水流转态分解转变成不连续的细小水雾滴喷射出来，因此它具有较高的电绝缘性能和良好的灭火性能。下列不属于水喷雾灭火机理的是（ ）。",[179,181,183,185],{"key":20,"text":180,"correct":22},"冷却",{"key":24,"text":182,"correct":26},"隔离",{"key":28,"text":184,"correct":22},"窒息",{"key":31,"text":186,"correct":22},"乳化",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":20,"analysis":33},933168,"水雾喷头常见的雾化角有30°、45°、60°、90°和（ ）等规格。",[191,193,195,197],{"key":20,"text":192,"correct":26},"120°",{"key":24,"text":194,"correct":22},"150°",{"key":28,"text":196,"correct":22},"165°",{"key":31,"text":198,"correct":22},"180°",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":24,"analysis":33},933169,"水喷雾灭火系统用于液体火灾灭火目的时，系统的响应时间不应大于（ ）s。",[203,205,206,207],{"key":20,"text":204,"correct":22},"45",{"key":24,"text":99,"correct":26},{"key":28,"text":101,"correct":22},{"key":31,"text":105,"correct":22},{"id":209,"libraryId":5,"type":15,"typeLabel":16,"stem":210,"options":211,"answer":24,"analysis":33},933170,"某工业建筑内设置电缆夹层设置自动灭火系统，宜选用（ ）。",[212,214,216,218],{"key":20,"text":213,"correct":22},"湿式自动喷水灭火系统",{"key":24,"text":215,"correct":26},"水喷雾灭火系统",{"key":28,"text":217,"correct":22},"水幕系统",{"key":31,"text":219,"correct":22},"预作用自动喷水灭火系统",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":31,"analysis":33},933171,"下列火灾中，不适合采用水喷雾灭火系统进行灭火的是（）。",[224,226,227,229],{"key":20,"text":225,"correct":22},"沥青火灾",{"key":24,"text":79,"correct":22},{"key":28,"text":228,"correct":22},"润滑油火灾",{"key":31,"text":230,"correct":26},"樟脑油火灾",{"id":232,"libraryId":5,"type":15,"typeLabel":16,"stem":233,"options":234,"answer":28,"analysis":33},933172,"某民用建筑内的柴油发电机房设置了水喷雾灭火系统进行保护，该系统设计响应时间为60s，则该系统宜采用（）报警阀组。",[235,237,239,241],{"key":20,"text":236,"correct":22},"湿式",{"key":24,"text":238,"correct":22},"预作用",{"key":28,"text":240,"correct":26},"雨淋",{"key":31,"text":242,"correct":22},"干式",{"id":244,"libraryId":5,"type":15,"typeLabel":16,"stem":245,"options":246,"answer":24,"analysis":33},933173,"用于液化石油气储罐防护冷却目的时，水雾喷头的工作压力不应小于（）MPa。",[247,249,251,253],{"key":20,"text":248,"correct":22},"0．35",{"key":24,"text":250,"correct":26},"0．2",{"key":28,"text":252,"correct":22},"0．15",{"key":31,"text":254,"correct":22},"0．1",{"id":256,"libraryId":5,"type":15,"typeLabel":16,"stem":257,"options":258,"answer":28,"analysis":33},933174,"某厂房采用水喷雾灭火系统保护，下列不属于水喷雾灭火系统灭火机理的是（ ）。",[259,260,262,264],{"key":20,"text":184,"correct":22},{"key":24,"text":261,"correct":22},"表面冷却",{"key":28,"text":263,"correct":26},"辐射热阻隔",{"key":31,"text":265,"correct":22},"稀释",{"id":267,"libraryId":5,"type":15,"typeLabel":16,"stem":268,"options":269,"answer":24,"analysis":33},933175,"水喷雾灭火系统按照启动方式分类，有（ ）种。",[270,271,272,273],{"key":20,"text":21,"correct":22},{"key":24,"text":25,"correct":26},{"key":28,"text":29,"correct":22},{"key":31,"text":32,"correct":22},{"id":275,"libraryId":5,"type":15,"typeLabel":16,"stem":276,"options":277,"answer":28,"analysis":33},933176,"充液传动管启动水喷雾灭火系统中，充液传动管的最高点应安装（ ）。",[278,280,282,284],{"key":20,"text":279,"correct":22},"冷凝器",{"key":24,"text":281,"correct":22},"气水分离器",{"key":28,"text":283,"correct":26},"自动排气阀",{"key":31,"text":285,"correct":22},"试水阀",{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":28,"analysis":33},933177,"水喷雾灭火系统用于液化石油气灌瓶间防护冷却时，水雾喷头的工作压力不应小于（ ）MPa。",[290,292,293,295],{"key":20,"text":291,"correct":22},"0．10",{"key":24,"text":252,"correct":22},{"key":28,"text":294,"correct":26},"0．20",{"key":31,"text":248,"correct":22},{"id":297,"libraryId":5,"type":15,"typeLabel":16,"stem":298,"options":299,"answer":31,"analysis":33},933178,"水喷雾灭火系统保护球罐时，关于水雾喷头布置的说法，错误的是（ ）。",[300,302,304,306],{"key":20,"text":301,"correct":22},"水雾喷头的喷口应朝向球心",{"key":24,"text":303,"correct":22},"水雾锥沿纬线方向应相交，沿经线方向应相接",{"key":28,"text":305,"correct":22},"无防护层的球罐钢支柱和罐体液位计、阀门等处应设水雾喷头保护",{"key":31,"text":307,"correct":26},"容积为1200m3的球罐，赤道以上环管之间的距离不应大于3．2m",{"id":309,"libraryId":5,"type":15,"typeLabel":16,"stem":310,"options":311,"answer":28,"analysis":33},933179,"某储存丙类液体的储罐区共有6座单座容积为1000m3的地上固定顶罐，分二排布置。每排三座，设置水喷雾灭火系统进行防护冷却。在计算该储罐区的消防冷却用水量时，应最终考虑同时冷却（ ）座储罐。",[312,313,314,315],{"key":20,"text":25,"correct":22},{"key":24,"text":32,"correct":22},{"key":28,"text":29,"correct":26},{"key":31,"text":148,"correct":22},{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":28,"analysis":33},933180,"水喷雾灭火系统用于灭火时，其响应时间不应大于（）s。",[320,321,322,323],{"key":20,"text":162,"correct":22},{"key":24,"text":101,"correct":22},{"key":28,"text":99,"correct":26},{"key":31,"text":105,"correct":22},{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":24,"analysis":33},933181,"水喷雾灭火系统用于柴油储罐的防护冷却时，水雾喷头的工作压力不应低于（ ）MPa。",[328,329,330,331],{"key":20,"text":248,"correct":22},{"key":24,"text":252,"correct":26},{"key":28,"text":250,"correct":22},{"key":31,"text":332,"correct":22},"0．4",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":20,"analysis":33},933182,"某丙类液体固定顶储罐，储罐容积为200m3，直径为20m。采用水喷雾灭火系统进行防护冷却，则水雾喷头与保护储罐外壁之间的距离不应大于（ ）。",[337,339,341,343],{"key":20,"text":338,"correct":26},"0.7",{"key":24,"text":340,"correct":22},"0.5",{"key":28,"text":342,"correct":22},"0.9",{"key":31,"text":21,"correct":22},{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":28,"analysis":33},933183,"水雾喷头的工作压力，当用于灭火时不应小于（ ）MPa。",[348,349,350,351],{"key":20,"text":252,"correct":22},{"key":24,"text":250,"correct":22},{"key":28,"text":248,"correct":26},{"key":31,"text":352,"correct":22},"0．5",{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":24,"analysis":33},933184,"下列不属于以灭火控火为目的的水喷雾系统适用范围的是（ ）。",[357,359,361,363],{"key":20,"text":358,"correct":22},"固体灭火",{"key":24,"text":360,"correct":26},"气体灭火",{"key":28,"text":362,"correct":22},"可燃液体灭火",{"key":31,"text":79,"correct":22},{"id":365,"libraryId":5,"type":15,"typeLabel":16,"stem":366,"options":367,"answer":28,"analysis":33},933185,"某液化石油气储罐，储罐容积900m3，罐体设有水喷雾灭火系统进行防护冷却，根据《水喷雾灭火系统技术规范》规定，水雾喷头的工作压力不应小于（）MPa。",[368,369,370,371],{"key":20,"text":248,"correct":22},{"key":24,"text":252,"correct":22},{"key":28,"text":250,"correct":26},{"key":31,"text":352,"correct":22},{"id":373,"libraryId":5,"type":374,"typeLabel":375,"stem":376,"options":377,"answer":386,"analysis":33},933186,2,"多选题","水喷雾灭火系统用于油浸变压器灭火保护时，系统响应时间符合规定的有（ ）s。",[378,379,381,383,384],{"key":20,"text":162,"correct":26},{"key":24,"text":380,"correct":26},"40",{"key":28,"text":382,"correct":26},"50",{"key":31,"text":99,"correct":26},{"key":385,"text":101,"correct":22},"E","ABCD",{"id":388,"libraryId":5,"type":374,"typeLabel":375,"stem":389,"options":390,"answer":401,"analysis":33},933187,"对于细水雾灭火系统，泵组系统的供水装置由储水箱、水泵、水泵控制柜（盘）、安全阀等部件组成，下列有关泵组系统供水装置的说法，正确的有（ ）。",[391,393,395,397,399],{"key":20,"text":392,"correct":22},"安全阀的动作压力应为系统最大工作压力的1．5倍",{"key":24,"text":394,"correct":26},"水泵采用柴油机作为动力时，应保证其能持续运行60min",{"key":28,"text":396,"correct":22},"水泵控制柜的防护等级不应低于IP55",{"key":31,"text":398,"correct":26},"储水箱应设置液位显示、高低液位报警装置和溢流、透气及放空装置",{"key":385,"text":400,"correct":26},"水泵应具有自动和手动启动功能以及巡检功能","BDE",{"id":403,"libraryId":5,"type":374,"typeLabel":375,"stem":404,"options":405,"answer":412,"analysis":33},933188,"根据使用场所的不同，闭式细水雾灭火系统又可以分为（ ）种形式。",[406,407,408,409,410],{"key":20,"text":236,"correct":26},{"key":24,"text":242,"correct":26},{"key":28,"text":238,"correct":26},{"key":31,"text":240,"correct":22},{"key":385,"text":411,"correct":22},"水幕","ABC",{"id":414,"libraryId":5,"type":374,"typeLabel":375,"stem":415,"options":416,"answer":427,"analysis":33},933189,"细水雾灭火系统的喷头按细水雾产生的原理可分为（ ）。",[417,419,421,423,425],{"key":20,"text":418,"correct":26},"撞击式",{"key":24,"text":420,"correct":22},"开式",{"key":28,"text":422,"correct":26},"离心式",{"key":31,"text":424,"correct":22},"闭式",{"key":385,"text":426,"correct":22},"通用式","AC",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":20,"analysis":33},933190,"下列有关开式细水雾灭火系统的说法中，错误的是（ ）。",[432,434,436,438],{"key":20,"text":433,"correct":26},"开式系统采用局部应用方式时，保护对象周围的气流速度不宜大于2m／s",{"key":24,"text":435,"correct":22},"开式系统采用全淹没应用方式时，防护区内影响灭火有效性的开口宜在系统动作时联动关闭",{"key":28,"text":437,"correct":22},"开式系统采用全淹没应用方式时，当防护区内的开口不能在系统启动时自动关闭时．宜在该开口部位的上方增设喷头",{"key":31,"text":439,"correct":22},"电缆夹层采用细水雾灭火系统保护时宜选择全淹没应用方式的开式系统",{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":20,"analysis":33},933191,"下列不属于细水雾灭火系统主要特性的是（ ）。",[444,446,448,450],{"key":20,"text":445,"correct":26},"化学抑制作用",{"key":24,"text":447,"correct":22},"电气绝缘性",{"key":28,"text":449,"correct":22},"节能环保性",{"key":31,"text":451,"correct":22},"烟雾消除作用",{"id":453,"libraryId":5,"type":15,"typeLabel":16,"stem":454,"options":455,"answer":20,"analysis":33},933192,"某设置在室内的油浸变压器采用开式细水雾灭火系统保护，当系统采用局部应用方式时，下列关于细水雾喷头布置的说法，错误的是（ ）。",[456,458,460,462],{"key":20,"text":457,"correct":26},"喷头布置应能保证细水雾完全包络或覆盖保护对象或部位，喷头与保护对象的距离不宜小于0．7m",{"key":24,"text":459,"correct":22},"当变压器高度超过4m时，喷头宜分层布置",{"key":28,"text":461,"correct":22},"当变压器下方设置集油坑时，喷头布置应能使细水雾完全覆盖集油坑",{"key":31,"text":463,"correct":22},"冷却器距变压器本体超过0．7m时，应在其间隙内增设喷头",{"id":465,"libraryId":5,"type":15,"typeLabel":16,"stem":466,"options":467,"answer":31,"analysis":33},933193,"某场所采用细水雾灭火系统保护，某型号细水雾喷头设计使用数量为200只，则该喷头备用量不应少于（ ）只。",[468,470,471,472],{"key":20,"text":469,"correct":22},"8",{"key":24,"text":29,"correct":22},{"key":28,"text":32,"correct":22},{"key":31,"text":148,"correct":26},{"id":474,"libraryId":5,"type":15,"typeLabel":16,"stem":475,"options":476,"answer":31,"analysis":33},933194,"下列关于闭式细水雾灭火系统喷头布置的说法中，错误的是（ ）。",[477,479,481,483],{"key":20,"text":478,"correct":22},"喷头布置应能保证细水雾喷放均匀、完全覆盖保护区域",{"key":24,"text":480,"correct":22},"喷头与其他遮挡物的距离应保证遮挡物不影响喷头正常喷放细水雾，当无法避免时，应采取补偿措施",{"key":28,"text":482,"correct":22},"喷头的感温组件与顶棚或梁底的距离不宜小于75mm，并不宜大于150mm，当场所内设置吊顶时，喷头可贴临吊顶布置",{"key":31,"text":484,"correct":26},"喷头与墙壁的距离不应小于喷头最大布置间距的1／2",{"id":486,"libraryId":5,"type":15,"typeLabel":16,"stem":487,"options":488,"answer":31,"analysis":33},933195,"下列关于细水雾灭火系统组件设置的说法中，正确的是（ ）。",[489,491,493,495],{"key":20,"text":490,"correct":22},"闭式系统应按防护区设置分区控制阀",{"key":24,"text":492,"correct":22},"开式系统应按楼层或防火分区设置分区控制阀",{"key":28,"text":494,"correct":22},"系统管网的最低点处应设置手动排气阀",{"key":31,"text":496,"correct":26},"闭式系统每个分区控制阀后的管网应设置试水阀",{"id":498,"libraryId":5,"type":15,"typeLabel":16,"stem":499,"options":500,"answer":28,"analysis":33},933196,"某场所采用细水雾灭火系统保护，该系统管网工作压力为3．65MPa，则该系统控制阀在选择时优先选择（ ）。",[501,503,505,507],{"key":20,"text":502,"correct":22},"雨淋阀",{"key":24,"text":504,"correct":22},"干式报警阀",{"key":28,"text":506,"correct":26},"分配阀",{"key":31,"text":508,"correct":22},"湿式报警阀",{"id":510,"libraryId":5,"type":15,"typeLabel":16,"stem":511,"options":512,"answer":28,"analysis":33},933197,"细水雾灭火系统的基本设计参数应根据细水雾灭火系统的特性和防护区的具体情况确定。喷头的最低设计工作压力不应小于（ ）MPa。",[513,515,516,518],{"key":20,"text":514,"correct":22},"0．05",{"key":24,"text":291,"correct":22},{"key":28,"text":517,"correct":26},"1．20",{"key":31,"text":519,"correct":22},"1．60",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":31,"analysis":33},933198,"基于细水雾灭火系统的灭火机理，下列场所中，细水雾灭火系统不适用于扑救的是（ ）。",[524,526,528,530],{"key":20,"text":525,"correct":22},"电缆夹层",{"key":24,"text":527,"correct":22},"柴油发电机",{"key":28,"text":529,"correct":22},"锅炉房",{"key":31,"text":531,"correct":26},"电石仓库",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":28,"analysis":33},933199,"采用局部应用方式的开式细水雾灭火系统，其保护面积的确定，下列说法错误的是（ ）。",[536,538,540,542],{"key":20,"text":537,"correct":22},"对于外形规则的保护对象，应为该保护对象的外表面面积",{"key":24,"text":539,"correct":22},"对于外形不规则的保护对象，应为包容该保护对象的最小规则形体的外表面面积",{"key":28,"text":541,"correct":26},"对于可能发生喷射火灾的保护对象，不应包括喷射火灾可能影响到的区域的水平投影面积",{"key":31,"text":543,"correct":22},"对于可能发生可燃液体流淌火灾的保护对象，应包括可燃液体流淌火灾可能影响到的区域的水平投影面积",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":24,"analysis":33},933200,"细水雾的灭火机理不包括（ ）",[548,549,550,551],{"key":20,"text":184,"correct":22},{"key":24,"text":265,"correct":26},{"key":28,"text":261,"correct":22},{"key":31,"text":263,"correct":22},{"id":553,"libraryId":5,"type":15,"typeLabel":16,"stem":554,"options":555,"answer":20,"analysis":33},933201,"细水雾灭火系统应按喷头的型号、规格存储备用喷头，其数量不应小于相同型号，规格喷头实际设计使用总数的（ ）。",[556,558,560,562],{"key":20,"text":557,"correct":26},"1％",{"key":24,"text":559,"correct":22},"5％",{"key":28,"text":561,"correct":22},"10％",{"key":31,"text":563,"correct":22},"15％",{"id":565,"libraryId":5,"type":15,"typeLabel":16,"stem":566,"options":567,"answer":28,"analysis":33},933202,"下列有关细水雾灭火系统设计参数的说法中，错误的是（ ）。",[568,570,572,574],{"key":20,"text":569,"correct":22},"喷头的最低设计工作压力不应小于1.20MPa",{"key":24,"text":571,"correct":22},"闭式系统的作用面积不宜小于140m2",{"key":28,"text":573,"correct":26},"采用全淹没应用方式的开式系统，其防护区数量不应大于4个",{"key":31,"text":575,"correct":22},"开式系统的设计响应时间不应大于30s",{"id":577,"libraryId":5,"type":15,"typeLabel":16,"stem":578,"options":579,"answer":20,"analysis":33},933203,"下列火灾中，可采用细水雾灭火系统进行扑救的是（ ）。",[580,582,584,586],{"key":20,"text":581,"correct":26},"汽油火灾",{"key":24,"text":583,"correct":22},"碳化钙火灾",{"key":28,"text":585,"correct":22},"纸张深位火灾",{"key":31,"text":587,"correct":22},"天然气火灾",[589,592,595,598,601,604],{"id":15,"name":590,"category":7,"favorite":591},"领导干部任职前廉政法规知识测试题",92,{"id":593,"name":594,"category":7,"favorite":15},595,"建筑结构与设备",{"id":596,"name":597,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":599,"name":600,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":602,"name":603,"category":7,"favorite":8},534,"BIM工程师",{"id":605,"name":603,"category":7,"favorite":8},535]