[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-29":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":632},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,29,50,2960,[13,34,46,58,70,82,93,105,117,127,139,151,163,175,186,198,210,222,234,246,258,270,282,294,306,318,330,342,353,363,373,385,394,404,416,432,447,462,477,492,506,521,535,549,563,575,587,599,611,622],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},933104,1,"单选题","防火分隔水幕的喷头布置，应保证水幕的宽度不小于6m，采用水幕喷头时，喷头不应少于（ ）排，采用开式洒水喷头时，喷头不应少于（ ）排。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","2，3",false,{"key":24,"text":25,"correct":22},"B","1，2",{"key":27,"text":28,"correct":29},"C","3，2",true,{"key":31,"text":32,"correct":22},"D","3，1","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},933105,"某剧场的座位数为2000个，剧场舞台口拟采用防火分隔水幕分隔，下列关于该防火分隔水幕设计的做法，不正确的是（）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"采用防火分隔水幕的宽度为20m",{"key":24,"text":41,"correct":29},"该防火分隔水幕的设计喷水强度为1．0L／s·m",{"key":27,"text":43,"correct":22},"该防火分隔水幕喷头的设计工作压力为0．1MPa",{"key":31,"text":45,"correct":22},"该防火分隔水幕的设计喷水点高度为10m",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},933106,"根据《自动喷水灭火系统设计规范》GB50084—2017的规定，下列用于保护建筑物中局部场所的系统，不可串联接入同一建筑物内湿式系统的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"雨淋系统",{"key":24,"text":53,"correct":29},"细水雾系统",{"key":27,"text":55,"correct":22},"预作用系统",{"key":31,"text":57,"correct":22},"自动喷水-泡沫联用系统",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},933107,"某商场中庭设置的防火卷帘采用水幕系统冷却，当喷头设置高度为6m时，系统喷水强度应为（ ）L／sm）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"0．5",{"key":24,"text":65,"correct":29},"0．7",{"key":27,"text":67,"correct":22},"1．0",{"key":31,"text":69,"correct":22},"2．0",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},933108,"某商场设置在地下一层，建筑面积为5600m2，建筑内设置湿式自动喷水灭火系统保护，下列关于该系统的说法，正确的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":29},"系统宜采用快速响应洒水喷头",{"key":24,"text":77,"correct":22},"系统参数应按中危险级Ⅰ级设计",{"key":27,"text":79,"correct":22},"系统可以采用消防洒水软管",{"key":31,"text":81,"correct":22},"系统不能选择两个厂家生产的同一规格、型号的洒水喷头",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":27,"analysis":33},933109,"下列属于开式自动喷水灭火系统的是（ ）。",[86,88,90,91],{"key":20,"text":87,"correct":22},"干式自动喷水灭火系统",{"key":24,"text":89,"correct":22},"预作用喷水灭火系统",{"key":27,"text":51,"correct":29},{"key":31,"text":92,"correct":22},"湿式自动喷水灭火系统",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":27,"analysis":33},933110,"下列选项中，不属于湿式自动喷水灭火系统组件的是（ ）。",[97,99,101,103],{"key":20,"text":98,"correct":22},"水流指示器",{"key":24,"text":100,"correct":22},"压力开关",{"key":27,"text":102,"correct":29},"加速器",{"key":31,"text":104,"correct":22},"闭式喷头",{"id":106,"libraryId":5,"type":15,"typeLabel":16,"stem":107,"options":108,"answer":31,"analysis":33},933111,"下列有关湿式系统、干式系统和预作用系统的说法，正确的是（ ）。",[109,111,113,115],{"key":20,"text":110,"correct":22},"湿式系统在准工作状态下，报警阀后的管道中充满有压气体",{"key":24,"text":112,"correct":22},"干式系统在准工作状态下，报警阀前后的管道中都充满水",{"key":27,"text":114,"correct":22},"预作用系统在准工作状态下，报警阀前后的管道中都充满有压气体",{"key":31,"text":116,"correct":29},"干式系统的启动原理与湿式系统相似，只是将传输喷头开放信号的介质由有压水改为有压气体",{"id":118,"libraryId":5,"type":15,"typeLabel":16,"stem":119,"options":120,"answer":24,"analysis":33},933112,"下列系统中不具备直接灭火能力的是（ ）。",[121,123,125,126],{"key":20,"text":122,"correct":22},"预作用自动喷水灭火系统",{"key":24,"text":124,"correct":29},"水幕系统",{"key":27,"text":51,"correct":22},{"key":31,"text":87,"correct":22},{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":31,"analysis":33},933113,"下列厂房中，需要设置自动灭火系统并宜设置自动喷水灭火系统的是（ ）。",[131,133,135,137],{"key":20,"text":132,"correct":22},"总建筑面积为3000m2的2层服装厂房",{"key":24,"text":134,"correct":22},"占地面积为1500m2单层木器厂房",{"key":27,"text":136,"correct":22},"建筑面积800m2的单层玩具厂房",{"key":31,"text":138,"correct":29},"建筑高度为25m的纺织厂厂房",{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":141,"options":142,"answer":24,"analysis":33},933114,"某单层会展中心，室内净空高度为9m，设置湿式自动喷水灭火系统保护，室内安装网格类吊顶，该系统的设计喷水强度不应小于（ ）L／minm2。",[143,145,147,149],{"key":20,"text":144,"correct":22},"8",{"key":24,"text":146,"correct":29},"15",{"key":27,"text":148,"correct":22},"20",{"key":31,"text":150,"correct":22},"19．5",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":20,"analysis":33},933115,"某场所安装橙色的闭式玻璃球洒水喷头，则该场所最高环境温度约为（ ）℃。",[155,157,159,161],{"key":20,"text":156,"correct":29},"28",{"key":24,"text":158,"correct":22},"38",{"key":27,"text":160,"correct":22},"50",{"key":31,"text":162,"correct":22},"57",{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":165,"options":166,"answer":27,"analysis":33},933116,"水力警铃与报警阀连接的管道管径应为（ ）mm，总长度不宜大于（ ）m。",[167,169,171,173],{"key":20,"text":168,"correct":22},"20，15",{"key":24,"text":170,"correct":22},"15，20",{"key":27,"text":172,"correct":29},"20，20",{"key":31,"text":174,"correct":22},"25，20",{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":24,"analysis":33},933117,"某建筑高度为32m的8层办公楼，每层建筑面积为6000m2，建筑内全部设置自动喷水系统，所设置的自动喷水灭火系统应至少设置（ ）个水流指示器。",[179,180,182,184],{"key":20,"text":144,"correct":22},{"key":24,"text":181,"correct":29},"16",{"key":27,"text":183,"correct":22},"24",{"key":31,"text":185,"correct":22},"32",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":27,"analysis":33},933118,"某单层公共建筑面积为3000m2，设有预作用自动喷水灭火系统保护，系统的设计参数按照火灾危险等级的中危险级Ⅱ级考虑，建筑内安装直立型标准覆盖面积洒水喷头，则该场所内至少应安装（ ）只喷头。",[190,192,194,196],{"key":20,"text":191,"correct":22},"186",{"key":24,"text":193,"correct":22},"253",{"key":27,"text":195,"correct":29},"261",{"key":31,"text":197,"correct":22},"304",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":27,"analysis":33},933119,"下列有关水流指示器的说法，正确的是（ ）。",[202,204,206,208],{"key":20,"text":203,"correct":22},"水流指示器的叶片应与水流方向平行",{"key":24,"text":205,"correct":22},"水流指示器的功能是将水流信号转换成电信号，并启动报警阀",{"key":27,"text":207,"correct":29},"报警阀组控制喷头只保护同层面积不超过防火分区时，可不设置水流指示器",{"key":31,"text":209,"correct":22},"当水流指示器前端设置控制阀时，应采用自锁蝶阀",{"id":211,"libraryId":5,"type":15,"typeLabel":16,"stem":212,"options":213,"answer":27,"analysis":33},933120,"某二级耐火等级的写字楼，地上6层，层高为4m，每层建筑面积为1000m2，建筑内全部设置了湿式自动喷水灭火系统，洒水喷头设置在格栅吊顶上部。下列关于该系统的说法，正确的是（ ）。",[214,216,218,220],{"key":20,"text":215,"correct":22},"系统设计参数应按火灾危险等级不低于中危险级1级设计",{"key":24,"text":217,"correct":22},"系统的喷水强度不应低于4L／（minm2）",{"key":27,"text":219,"correct":29},"系统的作用面积不小于160m2",{"key":31,"text":221,"correct":22},"采用了下垂型标准覆面积洒水喷头，喷头的最大保护面积为12．5m2",{"id":223,"libraryId":5,"type":15,"typeLabel":16,"stem":224,"options":225,"answer":31,"analysis":33},933121,"某商场地上6层，层高为6m，每层建筑面积为9600m2，建筑内装修材料全部采用不燃材料，并按现行国家消防技术标准设置了预作用自动喷水灭火系统、火灾自动报警系统和防烟排烟系统等。下列关于该商场建筑防火设计的说法中，正确的是（ ）。",[226,228,230,232],{"key":20,"text":227,"correct":22},"每层至少划分为2个防火分区",{"key":24,"text":229,"correct":22},"至少设置24个水流指示器",{"key":27,"text":231,"correct":22},"至少设置6个预作用报警阀组",{"key":31,"text":233,"correct":29},"至少设置7个末端试水装置",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":20,"analysis":33},933122,"下列有关防火分隔水幕系统的说法，正确的是（ ）。",[238,240,242,244],{"key":20,"text":239,"correct":29},"防火分隔水幕系统采用的是开式喷头或水幕喷头",{"key":24,"text":241,"correct":22},"防火分隔水幕系统喷头设置点高度不应超过4m",{"key":27,"text":243,"correct":22},"防火分隔水幕系统喷头的工作压力不应小于0．15MPa",{"key":31,"text":245,"correct":22},"防火分隔水幕系统持续喷水时间不应大于系统设置部位的耐火极限的要求",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":27,"analysis":33},933123,"下列有关自动喷水灭火系统报警阀组设置要求的说法，不正确的是（ ）。",[250,252,254,256],{"key":20,"text":251,"correct":22},"保护室内钢屋架等建筑构件的闭式系统，应设独立的报警阀组",{"key":24,"text":253,"correct":22},"水幕系统应设独立的报警阀组或感温雨淋报警阀",{"key":27,"text":255,"correct":29},"雨淋报警阀组的电磁阀入口前不应设过滤器",{"key":31,"text":257,"correct":22},"设置报警阀组的部位应设有排水设施",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":31,"analysis":33},933124,"某单层印刷厂，净空高度为8m，建筑面积为1800m2，设有室内消火栓系统和预作用自动喷水灭火系统，预作用系统采用由火灾自动报警系统和充气管道上设置的压力开关开启预作用装置。下列关于该预作用自动喷水灭火系统设计的说法中，不正确的是（ ）。",[262,264,266,268],{"key":20,"text":263,"correct":22},"系统的作用面积不应小于338m2",{"key":24,"text":265,"correct":22},"系统喷水强度不应小于12L／（minm2）",{"key":27,"text":267,"correct":22},"系统配水管道充水时间不宜大于1min",{"key":31,"text":269,"correct":29},"系统可以选择扩大覆盖面积的下垂型洒水喷头",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":27,"analysis":33},933125,"下列场所或部位可以不设置自动喷水灭火系统的是（ ）。",[274,276,278,280],{"key":20,"text":275,"correct":22},"占地面积为2000m2的木器厂房",{"key":24,"text":277,"correct":22},"建筑高度为30m的高锰酸钾厂房",{"key":27,"text":279,"correct":29},"建筑高度为18m且占地面积为1500m2的木器厂房",{"key":31,"text":281,"correct":22},"建筑高度为15m泡沫塑料厂的预发、成型部位",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":27,"analysis":33},933126,"某商业中心，总建筑面积为9000m2，顶部采用网格类通透性吊顶进行装饰。该商业中心在设置自动喷水灭火系统时，系统的设计喷水强度和作用面积分别不应低于（ ）。",[286,288,290,292],{"key":20,"text":287,"correct":22},"6和160",{"key":24,"text":289,"correct":22},"8和208",{"key":27,"text":291,"correct":29},"10.4和160",{"key":31,"text":293,"correct":22},"10.4和208",{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":20,"analysis":33},933127,"下列有关自动喷水灭火系统设计流量的说法，不正确的是（ ）。",[298,300,302,304],{"key":20,"text":299,"correct":29},"防护冷却系统保护防火卷帘时，系统的设计流量应按计算长度内一只喷头的喷水流量确定",{"key":24,"text":301,"correct":22},"雨淋系统的设计流量，应按雨淋报警阀控制的洒水喷头的流量之和确定",{"key":27,"text":303,"correct":22},"水幕系统的设计流量，应按雨淋报警阀控制的洒水喷头的流量之和确定",{"key":31,"text":305,"correct":22},"设置货架内置喷头的仓库，顶板下喷头与货架内喷头应分别计算设计流量，并应按其设计流量之和确定系统的设计流量",{"id":307,"libraryId":5,"type":15,"typeLabel":16,"stem":308,"options":309,"answer":27,"analysis":33},933128,"某商场的中庭与周围连通空间采用防火卷帘进行分隔，并采用防护冷却水幕保护该防火卷帘，水幕喷水点的高度为5m，下列关于该防护冷却水幕的说法中，不正确的是（）。",[310,312,314,316],{"key":20,"text":311,"correct":22},"该防护冷却水幕的喷头宜布置成单排",{"key":24,"text":313,"correct":22},"该防护冷却水幕的喷头工作压力不应低于0．1MPa",{"key":27,"text":315,"correct":29},"该防护冷却水幕的喷水强度不应小于0．5L／（s·m）",{"key":31,"text":317,"correct":22},"该防护冷却水幕系统的持续喷水时间不应小于3．00h",{"id":319,"libraryId":5,"type":15,"typeLabel":16,"stem":320,"options":321,"answer":24,"analysis":33},933129,"下列建筑或场所中，应设置自动灭火系统并宜采用自动喷水灭火系统的是（ ）。",[322,324,326,328],{"key":20,"text":323,"correct":22},"某建筑高度为5．6m的2层网吧，每层建筑面积为300m2",{"key":24,"text":325,"correct":29},"某总建筑面积为400m2的单层老年人照料设施",{"key":27,"text":327,"correct":22},"某建筑高度为15．8m的3层商店，每层建筑面积为1000m2",{"key":31,"text":329,"correct":22},"某座位数为1500个的单层礼堂",{"id":331,"libraryId":5,"type":15,"typeLabel":16,"stem":332,"options":333,"answer":27,"analysis":33},933130,"喷头是自动喷水灭火系统的主要组件之一，根据其灵敏性，响应时间指数RTI≤50（m·s）0.5的喷头属于（ ）。",[334,336,338,340],{"key":20,"text":335,"correct":22},"标准响应喷头",{"key":24,"text":337,"correct":22},"早期抑制快速响应喷头",{"key":27,"text":339,"correct":29},"快速响应喷头",{"key":31,"text":341,"correct":22},"特殊响应喷头",{"id":343,"libraryId":5,"type":15,"typeLabel":16,"stem":344,"options":345,"answer":31,"analysis":33},933131,"某新建商场总建筑面积为 6000 ㎡，室内净空 4.0m，采用石膏板吊顶，设计采用预作用自动喷水灭火系统进行保护，则其设计喷水强度不应小于（ ）L\u002Fmin·㎡。",[346,348,350,352],{"key":20,"text":347,"correct":22},"6",{"key":24,"text":349,"correct":22},"10",{"key":27,"text":351,"correct":22},"4",{"key":31,"text":144,"correct":29},{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":31,"analysis":33},933132,"（ ）的功能是能够及时报告发生火灾的部位。",[357,358,360,362],{"key":20,"text":100,"correct":22},{"key":24,"text":359,"correct":22},"水力警铃",{"key":27,"text":361,"correct":22},"延迟器",{"key":31,"text":98,"correct":29},{"id":364,"libraryId":5,"type":15,"typeLabel":16,"stem":365,"options":366,"answer":31,"analysis":33},933133,"防火分隔水幕宽度不宜小于（ ）m。",[367,369,370,372],{"key":20,"text":368,"correct":22},"3",{"key":24,"text":351,"correct":22},{"key":27,"text":371,"correct":22},"5",{"key":31,"text":347,"correct":29},{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":24,"analysis":33},933134,"水力警铃的工作压力不应小于（ ）。",[377,379,381,383],{"key":20,"text":378,"correct":22},"0．03MPa",{"key":24,"text":380,"correct":29},"0．05MPa",{"key":27,"text":382,"correct":22},"0．08MPa",{"key":31,"text":384,"correct":22},"0．1MPa",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":27,"analysis":33},933135,"发生火灾时，湿式自动喷水灭火系统是由（ ）探测火灾。",[389,391,392,393],{"key":20,"text":390,"correct":22},"火灾探测器",{"key":24,"text":98,"correct":22},{"key":27,"text":104,"correct":29},{"key":31,"text":100,"correct":22},{"id":395,"libraryId":5,"type":15,"typeLabel":16,"stem":396,"options":397,"answer":24,"analysis":33},933136,"某高层建筑，建筑高度60m，共20层，每层均安装有湿式自动喷水灭火系统，根据计算，需安装750个喷头，则此建筑最少需要安装（ ）套湿式报警阀组。",[398,400,402,403],{"key":20,"text":399,"correct":22},"1",{"key":24,"text":401,"correct":29},"2",{"key":27,"text":368,"correct":22},{"key":31,"text":351,"correct":22},{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":27,"analysis":33},933137,"北方某高档五星级宾馆设有一层地下停车库，无采暖设施。由于接待规格较高，因此在设计时需考虑地下车库消防设施不能有误动作喷水现象。则需安装（ ）自动喷水灭火系统。",[408,410,412,414],{"key":20,"text":409,"correct":22},"湿式",{"key":24,"text":411,"correct":22},"干式",{"key":27,"text":413,"correct":29},"预作用",{"key":31,"text":415,"correct":22},"雨淋",{"id":417,"libraryId":5,"type":418,"typeLabel":419,"stem":420,"options":421,"answer":431,"analysis":33},933138,2,"多选题","某商场总建筑面积为4000m2，室内高度为4．5m，建筑内全部设置了干式自动喷水灭火系统。下列关于该系统的说法，正确的有（ ）。",[422,423,424,426,428],{"key":20,"text":215,"correct":29},{"key":24,"text":217,"correct":22},{"key":27,"text":425,"correct":22},"系统的保护面积不应小于160m2",{"key":31,"text":427,"correct":29},"商场内一只喷头的保护面积为9m2",{"key":429,"text":430,"correct":29},"E","系统可采用直立型洒水喷头","ADE",{"id":433,"libraryId":5,"type":418,"typeLabel":419,"stem":434,"options":435,"answer":446,"analysis":33},933139,"下列关于自动喷水灭火系统设置场所和对应的火灾危险等级的说法，正确的有（ ）。",[436,438,440,442,444],{"key":20,"text":437,"correct":22},"二级耐火等级的造纸厂，建筑面积3000m2，火灾危险性为严重危险Ⅰ级",{"key":24,"text":439,"correct":22},"总面积为100m2的地下商场，火灾危险等级为严重危险Ⅰ级",{"key":27,"text":441,"correct":29},"地下停车场，建筑面积2600m2，火灾危险等级为中危险Ⅱ级",{"key":31,"text":443,"correct":22},"火车站候车厅，建筑面积3400m2，火灾危险等级为中危险Ⅱ级",{"key":429,"text":445,"correct":29},"国家级文物保护单位，火灾危险等级为中危险Ⅰ级","CE",{"id":448,"libraryId":5,"type":418,"typeLabel":419,"stem":449,"options":450,"answer":461,"analysis":33},933140,"下列关于水幕系统的叙述正确的是（ ）。",[451,453,455,457,459],{"key":20,"text":452,"correct":29},"由开式洒水喷头或水幕喷头、雨淋报警阀组或感温雨淋阀以及水流报警装置（水流指示器或压力开关）等组成,用于挡烟阻火和冷却分隔物的喷水系统",{"key":24,"text":454,"correct":22},"水幕系统使用的雨淋阀组可以不设水力警铃和延迟器",{"key":27,"text":456,"correct":29},"防火分隔水幕不宜用于尺寸超过 15m（宽）×8m（高）的开口（舞台口除外）",{"key":31,"text":458,"correct":22},"水幕系统雨淋阀组可以向一个保护对象或多处防火分隔空间喷水",{"key":429,"text":460,"correct":29},"水幕系统喷水与报警阀动作关系为报警阀先动作,喷头随报警阀开放而喷水","ACE",{"id":463,"libraryId":5,"type":418,"typeLabel":419,"stem":464,"options":465,"answer":476,"analysis":33},933141,"自动喷水灭火系统的报警阀组可分为（ ）。",[466,468,470,472,474],{"key":20,"text":467,"correct":29},"湿式报警阀组",{"key":24,"text":469,"correct":29},"干式报警阀组",{"key":27,"text":471,"correct":22},"水幕报警阀组",{"key":31,"text":473,"correct":29},"雨淋报警阀组",{"key":429,"text":475,"correct":29},"预作用报警装置","ABDE",{"id":478,"libraryId":5,"type":418,"typeLabel":419,"stem":479,"options":480,"answer":491,"analysis":33},933142,"下列应采用自动喷水灭火预作用系统的是（ ）。",[481,483,485,487,489],{"key":20,"text":482,"correct":29},"系统处于准工作状态时严禁误喷的场所",{"key":24,"text":484,"correct":22},"火灾的水平蔓延速度快、闭式洒水喷头的开放不能及时使喷水有效覆盖着火区域的场所",{"key":27,"text":486,"correct":29},"系统处于准工作状态时严禁管道充水的场所",{"key":31,"text":488,"correct":29},"用于替代干式系统的场所",{"key":429,"text":490,"correct":22},"火灾危险等级为严重危险级Ⅱ级的场所","ACD",{"id":493,"libraryId":5,"type":418,"typeLabel":419,"stem":494,"options":495,"answer":476,"analysis":33},933143,"自动喷水灭火系统设置场所的火灾危险等级有（ ）。",[496,498,500,502,504],{"key":20,"text":497,"correct":29},"轻危险级",{"key":24,"text":499,"correct":29},"中危险级",{"key":27,"text":501,"correct":22},"重危险级",{"key":31,"text":503,"correct":29},"严重危险级",{"key":429,"text":505,"correct":29},"仓库危险级",{"id":507,"libraryId":5,"type":418,"typeLabel":419,"stem":508,"options":509,"answer":520,"analysis":33},933144,"水喷雾灭火系统的雾化效果与水雾喷头的性能参数有关，下列属于水雾喷头的主要性能参数的是（ ）。",[510,512,514,516,518],{"key":20,"text":511,"correct":29},"工作压力",{"key":24,"text":513,"correct":29},"雾化角",{"key":27,"text":515,"correct":29},"流量系数",{"key":31,"text":517,"correct":22},"安装高度",{"key":429,"text":519,"correct":29},"有效射程","ABCE",{"id":522,"libraryId":5,"type":418,"typeLabel":419,"stem":523,"options":524,"answer":446,"analysis":33},933145,"下列火灾可用水喷雾灭火系统进行扑救的有（ ）。",[525,527,529,531,533],{"key":20,"text":526,"correct":22},"过氧化钡仓库火灾",{"key":24,"text":528,"correct":22},"高温密闭容器内发生的火灾",{"key":27,"text":530,"correct":29},"充可燃油的高压电容器火灾",{"key":31,"text":532,"correct":22},"表面温度经常处于高温状态的可燃液体火灾",{"key":429,"text":534,"correct":29},"白兰地成品仓库",{"id":536,"libraryId":5,"type":418,"typeLabel":419,"stem":537,"options":538,"answer":520,"analysis":33},933146,"下列关于雨淋阀组设置要求的说法，正确的有（ ）。",[539,541,543,545,547],{"key":20,"text":540,"correct":29},"雨淋阀组宜设在环境温度不低于4℃，并有排水设施的室内，其位置宜靠近保护对象并便于操作",{"key":24,"text":542,"correct":29},"雨淋阀组设在室外时，雨淋阀组配件应具有防腐功能，设在防爆区的雨淋阀组配件应符合防爆要求",{"key":27,"text":544,"correct":29},"寒冷地区的雨淋阀组应采用电伴热或蒸汽伴热进行保温",{"key":31,"text":546,"correct":22},"并联设置的雨淋阀组，雨淋阀入口处应设安全阀",{"key":429,"text":548,"correct":29},"当水雾喷头无滤网时，雨淋阀后的管道上也应设置过滤器",{"id":550,"libraryId":5,"type":418,"typeLabel":419,"stem":551,"options":552,"answer":491,"analysis":33},933147,"下列不适宜用水扑救的是（ ）。",[553,555,557,559,561],{"key":20,"text":554,"correct":29},"过氧化钾",{"key":24,"text":556,"correct":22},"电缆井",{"key":27,"text":558,"correct":29},"金属钠",{"key":31,"text":560,"correct":29},"碳化钾",{"key":429,"text":562,"correct":22},"燃油锅炉",{"id":564,"libraryId":5,"type":15,"typeLabel":16,"stem":565,"options":566,"answer":31,"analysis":33},933148,"当水喷雾灭火系统以防护冷却为目的时，下列建筑或场所中不适用的是（ ）。",[567,569,571,573],{"key":20,"text":568,"correct":22},"甲类液体储罐区",{"key":24,"text":570,"correct":22},"液氨储罐",{"key":27,"text":572,"correct":22},"蒸馏塔",{"key":31,"text":574,"correct":29},"硫磺回收厂房",{"id":576,"libraryId":5,"type":15,"typeLabel":16,"stem":577,"options":578,"answer":27,"analysis":33},933149,"下列场所或部位，不得采用水喷雾灭火系统扑救的是（ ）。",[579,581,583,585],{"key":20,"text":580,"correct":22},"发电机油箱发生的火灾",{"key":24,"text":582,"correct":22},"油浸电力变压器室发生的火灾",{"key":27,"text":584,"correct":29},"碳化钙仓库发生的火灾",{"key":31,"text":586,"correct":22},"电缆发生的火灾",{"id":588,"libraryId":5,"type":15,"typeLabel":16,"stem":589,"options":590,"answer":27,"analysis":33},933150,"下列关于水喷雾灭火系统保护面积的说法中，错误的是（ ）。",[591,593,595,597],{"key":20,"text":592,"correct":22},"可燃气体压缩机保护面积应按相应设备的投影面积确定，且水雾应包络密封面和其他关键部位",{"key":24,"text":594,"correct":22},"开口容器的保护面积应按其液面面积确定",{"key":27,"text":596,"correct":29},"输送机皮带的保护面积应按下行皮带的下表面积确定",{"key":31,"text":598,"correct":22},"液化石油气灌瓶间的保护面积应按其使用面积确定",{"id":600,"libraryId":5,"type":15,"typeLabel":16,"stem":601,"options":602,"answer":24,"analysis":33},933151,"水喷雾系统用于冷却甲 B、乙、丙类液体储罐时，关于其冷却范围及保护面积的说法，不正确的是（ ）。",[603,605,607,609],{"key":20,"text":604,"correct":22},"着火的浮顶罐应冷却，其相邻储罐可不冷却",{"key":24,"text":606,"correct":29},"着火的浮顶罐应冷却，其相邻储罐应同时冷却",{"key":27,"text":608,"correct":22},"着火罐的保护面积应按罐壁外表面面积计算",{"key":31,"text":610,"correct":22},"着火的地上固定顶储罐及距着火储罐罐壁1．5倍着火罐直径范围内的相邻地上储罐应同时冷却",{"id":612,"libraryId":5,"type":15,"typeLabel":16,"stem":613,"options":614,"answer":27,"analysis":33},933152,"某柴油发电机房设置了水喷雾灭火系统，当以灭火为目的时，该系统的响应时间不应大于（ ）s。",[615,616,618,620],{"key":20,"text":146,"correct":22},{"key":24,"text":617,"correct":22},"45",{"key":27,"text":619,"correct":29},"60",{"key":31,"text":621,"correct":22},"90",{"id":623,"libraryId":5,"type":15,"typeLabel":16,"stem":624,"options":625,"answer":24,"analysis":33},933153,"水喷雾灭火系统保护可燃气体储罐时，水雾喷头与保护储罐外壁之间的距离不应大于（ ）m。",[626,627,628,630],{"key":20,"text":63,"correct":22},{"key":24,"text":65,"correct":29},{"key":27,"text":629,"correct":22},"0．9",{"key":31,"text":631,"correct":22},"1．2",[633,636,639,642,645,648],{"id":15,"name":634,"category":7,"favorite":635},"领导干部任职前廉政法规知识测试题",92,{"id":637,"name":638,"category":7,"favorite":15},595,"建筑结构与设备",{"id":640,"name":641,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":643,"name":644,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":646,"name":647,"category":7,"favorite":8},534,"BIM工程师",{"id":649,"name":647,"category":7,"favorite":8},535]