[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-28":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":558},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,28,50,2960,[13,34,46,58,70,82,94,106,118,128,140,152,164,174,186,195,207,219,229,241,253,265,277,286,294,303,311,323,335,344,353,361,373,381,393,401,412,424,432,441,449,457,469,478,490,502,514,526,538,547],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},933054,1,"单选题","某耐火等级为二级的6层建筑，高度为28m，每层建筑面积为12000m2，首层设有净空高度为6．2m的商店营业厅。建筑内全部采用不燃或难燃材料进行装修，并设置了湿式自动喷水灭火系统和火灾自动报警系统保护，该商店营业厅内至少应设置（ ）个水流指示器。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","20",false,{"key":24,"text":25,"correct":26},"B","3",true,{"key":28,"text":29,"correct":22},"C","4",{"key":31,"text":32,"correct":22},"D","18","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},933055,"关于末端试水装置设置的说法，错误的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"末端试水装置和试水阀应设在便于操作的部位",{"key":24,"text":41,"correct":22},"每个报警阀组控制的最不利点喷头处应设置末端试水装置",{"key":28,"text":43,"correct":22},"末端试水装置的出水，应采用孔口出流的方式排入排水管道",{"key":31,"text":45,"correct":26},"末端试水装置出水口的流量数，应大于与系统同楼层选用的喷头数",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},933056,"某地下商场，设置的自动喷水灭火系统采用直立型喷头，当喷头无障碍物遮挡时，符合规定的喷头溅水盘与顶板的距离是（ ）mm。",[50,52,54,56],{"key":20,"text":51,"correct":22},"65",{"key":24,"text":53,"correct":26},"135",{"key":28,"text":55,"correct":22},"165",{"key":31,"text":57,"correct":22},"170",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},933057,"自动喷水灭火系统报警阀组宜设在安全且易于操作、检修的地点，环境温度不低于4℃且不高于70℃，距地面的距离宜为（ ）m。",[62,64,66,68],{"key":20,"text":63,"correct":22},"1．0",{"key":24,"text":65,"correct":26},"1．2",{"key":28,"text":67,"correct":22},"1．5",{"key":31,"text":69,"correct":22},"2．0",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},933058,"下列场所设置自动喷水灭火系统进行保护，在进行喷头选型时，做法错误的是（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":26},"某未做吊项的场所，设置湿式系统保护，配水支管布置在梁下，采用了下垂型喷头",{"key":24,"text":77,"correct":22},"某设置吊顶的场所，设置湿式系统保护，在吊顶下布置喷头，采用了下垂型喷头",{"key":28,"text":79,"correct":22},"某顶板为水平面的单位办公楼，设置湿式系统保护，办公室采用了边墙型喷头",{"key":31,"text":81,"correct":22},"某工厂设备间，设置预作用系统保护，采用了干式下垂型喷头",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":24,"analysis":33},933059,"按照防护冷却系统设计的基本参数,防护冷却系统保护防火卷帘的喷水点高度为 8m ,喷水强度应该是（ ）L\u002F（s.m）",[86,88,90,92],{"key":20,"text":87,"correct":22},"0.5",{"key":24,"text":89,"correct":26},"0.9",{"key":28,"text":91,"correct":22},"1.0",{"key":31,"text":93,"correct":22},"2.0",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},933060,"某印刷厂，火灾危险等级为严重Ⅰ级，设湿式自动喷水灭火系统全保护，则配水支管控制的喷头数量最多为（ ）个。",[98,100,102,104],{"key":20,"text":99,"correct":22},"9",{"key":24,"text":101,"correct":22},"10",{"key":28,"text":103,"correct":22},"8",{"key":31,"text":105,"correct":26},"6",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":20,"analysis":33},933061,"下列建筑中，自动喷水灭火系统设置场所的火灾危险等级为中危险级Ⅰ级的是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":26},"建筑高度50m的办公楼",{"key":24,"text":113,"correct":22},"汽车停车场（库）",{"key":28,"text":115,"correct":22},"2000个座位剧场的舞台",{"key":31,"text":117,"correct":22},"总建筑面积5500m2的商场",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":28,"analysis":33},933062,"自动喷水灭火系统报警阀组宜设在安全及易于操作的地点，报警阀距地面的高度宜为（ ）m。",[122,124,126,127],{"key":20,"text":123,"correct":22},"0．8",{"key":24,"text":125,"correct":22},"1．1",{"key":28,"text":65,"correct":26},{"key":31,"text":67,"correct":22},{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":20,"analysis":33},933063,"对于自动喷水灭火干式系统，应采用（ ）喷头。",[132,134,136,138],{"key":20,"text":133,"correct":26},"直立型",{"key":24,"text":135,"correct":22},"边墙型",{"key":28,"text":137,"correct":22},"扩大覆盖面积洒水",{"key":31,"text":139,"correct":22},"吊顶型",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":24,"analysis":33},933064,"不具备直接灭火能力，用于防火分隔和冷却保护分隔物的防火系统为（ ）。",[144,146,148,150],{"key":20,"text":145,"correct":22},"雨淋系统",{"key":24,"text":147,"correct":26},"水幕系统",{"key":28,"text":149,"correct":22},"自动喷水—泡沫联用系统",{"key":31,"text":151,"correct":22},"湿式系统",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":28,"analysis":33},933065,"在准工作状态时配水管道内不充水，发生火灾时，由火灾报警系统、充气管道上的压力开关联锁控制预作用装置和启动消防水泵，并转换为湿式系统的灭火系统为（ ）灭火系统。",[156,158,160,162],{"key":20,"text":157,"correct":22},"湿式自动喷水",{"key":24,"text":159,"correct":22},"干式自动喷水",{"key":28,"text":161,"correct":26},"预作用自动喷水",{"key":31,"text":163,"correct":22},"雨淋",{"id":165,"libraryId":5,"type":15,"typeLabel":16,"stem":166,"options":167,"answer":28,"analysis":33},933066,"某4层地上商店建筑，每层建筑面积为8500m2，所设置的湿式自动喷水灭火系统共使用了2960只闭式喷头，该系统应设置（ ）个末端试水装置。",[168,170,171,172],{"key":20,"text":169,"correct":22},"2",{"key":24,"text":25,"correct":22},{"key":28,"text":29,"correct":26},{"key":31,"text":173,"correct":22},"5",{"id":175,"libraryId":5,"type":15,"typeLabel":16,"stem":176,"options":177,"answer":20,"analysis":33},933067,"早期抑制快速响应喷头指流量系数K≥161，某洒水喷头的响应时间指数为RTI",[178,180,182,184],{"key":20,"text":179,"correct":26},"早期抑制快速响应喷头",{"key":24,"text":181,"correct":22},"快速响应洒水喷头",{"key":28,"text":183,"correct":22},"特殊响应洒水喷头",{"key":31,"text":185,"correct":22},"标准响应洒水喷头",{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":28,"analysis":33},933068,"某玻璃瓶制品厂房设置自动喷水灭火系统，则DN50的配水支管控制的标准喷头数最大为（ ）只。",[190,191,192,193],{"key":20,"text":29,"correct":22},{"key":24,"text":105,"correct":22},{"key":28,"text":103,"correct":26},{"key":31,"text":194,"correct":22},"12",{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":24,"analysis":33},933069,"防护冷却系统和防护冷却水幕系统描述错误的是（）。",[199,201,203,205],{"key":20,"text":200,"correct":22},"使用的喷头类型不同",{"key":24,"text":202,"correct":26},"防护冷却系统是开式系统，防护冷却水幕系统是闭式系统",{"key":28,"text":204,"correct":22},"喷头最大设置点高度不同",{"key":31,"text":206,"correct":22},"持续喷水时间与系统保护部位的耐火极限有关",{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":24,"analysis":33},933070,"自动喷水灭火系统设置场所的火灾危险等级，共分为4类8级，其中（ ）指可燃物数量、火灾放热速率为中等，火灾初期不会引起剧烈燃烧的场所。",[211,213,215,217],{"key":20,"text":212,"correct":22},"轻危险级",{"key":24,"text":214,"correct":26},"中危险级",{"key":28,"text":216,"correct":22},"严重危险级",{"key":31,"text":218,"correct":22},"仓库火灾危险级",{"id":220,"libraryId":5,"type":15,"typeLabel":16,"stem":221,"options":222,"answer":31,"analysis":33},933071,"某总建筑面积为5000m2的商场，其自动喷水灭火系统的设计参数应按火灾危险等级不低于（ ）确定。",[223,224,226,227],{"key":20,"text":212,"correct":22},{"key":24,"text":225,"correct":22},"中危险Ⅰ级",{"key":28,"text":216,"correct":22},{"key":31,"text":228,"correct":26},"中危险Ⅱ级",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":24,"analysis":33},933072,"下列选项中，自动喷水灭火系统设置场所的火灾危险等级为中危险级Ⅰ级的是（ ）。",[233,235,237,239],{"key":20,"text":234,"correct":22},"建筑高度为24m的旅馆",{"key":24,"text":236,"correct":26},"建筑高度为25m的医院",{"key":28,"text":238,"correct":22},"仅在走道设置闭式系统的办公楼",{"key":31,"text":240,"correct":22},"舞台（葡萄架除外）",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":24,"analysis":33},933073,"某总建筑面积为5000m2的商场，采用干式自动喷水灭火系统，该系统的作用面积不应小于（ ）m2。",[245,247,249,251],{"key":20,"text":246,"correct":22},"160",{"key":24,"text":248,"correct":26},"208",{"key":28,"text":250,"correct":22},"260",{"key":31,"text":252,"correct":22},"338",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":28,"analysis":33},933074,"设置自动喷水灭火系统的仓库及类似场所，当采用货架储存时应采用钢制货架，并应采用通透层板，且层板中通透部分的面积不应小于层板总面积的（ ）。",[257,259,261,263],{"key":20,"text":258,"correct":22},"10％",{"key":24,"text":260,"correct":22},"30％",{"key":28,"text":262,"correct":26},"50％",{"key":31,"text":264,"correct":22},"70％",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":24,"analysis":33},933075,"下列建筑可采用局部应用湿式自动喷水灭火系统的是（ ）。",[269,271,273,275],{"key":20,"text":270,"correct":22},"室内净空高度为7m，总建筑面积为800m2的厂房",{"key":24,"text":272,"correct":26},"室内净空高度为7m，总建筑面积为800m2的民用建筑",{"key":28,"text":274,"correct":22},"室内净空高度为9m，总建筑面积为1000m2的厂房建筑",{"key":31,"text":276,"correct":22},"室内净空高度为9m，总建筑面积为1000m2的民用建筑",{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":20,"analysis":33},933076,"自动喷水灭火系统的持续喷水时间，一般按火灾延续时间不小于（ ）h确定。",[281,282,284,285],{"key":20,"text":63,"correct":26},{"key":24,"text":283,"correct":22},"0．5",{"key":28,"text":67,"correct":22},{"key":31,"text":69,"correct":22},{"id":287,"libraryId":5,"type":15,"typeLabel":16,"stem":288,"options":289,"answer":28,"analysis":33},933077,"局部应用湿式自动喷水灭火系统采用快速响应洒水喷头时，系统持续喷水时间不应低于（ ）h。",[290,291,292,293],{"key":20,"text":67,"correct":22},{"key":24,"text":63,"correct":22},{"key":28,"text":283,"correct":26},{"key":31,"text":69,"correct":22},{"id":295,"libraryId":5,"type":15,"typeLabel":16,"stem":296,"options":297,"answer":28,"analysis":33},933078,"对于预作用自动喷水灭火系统来说，系统在选择洒水喷头时应选择（ ）洒水喷头。",[298,299,300,301],{"key":20,"text":139,"correct":22},{"key":24,"text":135,"correct":22},{"key":28,"text":133,"correct":26},{"key":31,"text":302,"correct":22},"下垂型",{"id":304,"libraryId":5,"type":15,"typeLabel":16,"stem":305,"options":306,"answer":24,"analysis":33},933079,"某地下商场设有湿式自动喷水灭火系统，该系统在选择洒水喷头时宜选择（ ）。",[307,308,309,310],{"key":20,"text":179,"correct":22},{"key":24,"text":181,"correct":26},{"key":28,"text":183,"correct":22},{"key":31,"text":185,"correct":22},{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":20,"analysis":33},933080,"下垂型标准喷头安装在顶板下方时，其溅水盘与顶板的距离不应小于（ ）mm且不大于（ ）mm。",[315,317,319,321],{"key":20,"text":316,"correct":26},"75．150",{"key":24,"text":318,"correct":22},"75．300",{"key":28,"text":320,"correct":22},"25，100",{"key":31,"text":322,"correct":22},"25，550",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":20,"analysis":33},933081,"下列关于湿式自动灭火系统洒水喷头选取的说法中，错误的是（ ）。",[327,329,331,333],{"key":20,"text":328,"correct":26},"不做吊顶的场所，当配水支管布置在梁下时，应采用下垂型洒水喷头",{"key":24,"text":330,"correct":22},"顶板为水平面的轻危险级旅馆，可采用边墙型喷头",{"key":28,"text":332,"correct":22},"易受碰撞的部位，应采用带保护罩的洒水喷头或吊顶型洒水喷头",{"key":31,"text":334,"correct":22},"吊顶下布置的洒水喷头，应采用下垂型洒水喷头或吊顶型洒水喷头",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":28,"analysis":33},933082,"某6层建筑，每层划分三个防火分区，建筑内设置湿式自动喷水灭火系统，则该系统应至少设置（ ）个水流指示器。",[339,340,341,342],{"key":20,"text":105,"correct":22},{"key":24,"text":194,"correct":22},{"key":28,"text":32,"correct":26},{"key":31,"text":343,"correct":22},"24",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":20,"analysis":33},933083,"由火灾自动报警系统和充气管道上设置的压力开关开启预作用装置的预作用系统，配水管道充水时间不宜大于（ ）min。",[348,350,351,352],{"key":20,"text":349,"correct":26},"1",{"key":24,"text":169,"correct":22},{"key":28,"text":25,"correct":22},{"key":31,"text":173,"correct":22},{"id":354,"libraryId":5,"type":15,"typeLabel":16,"stem":355,"options":356,"answer":24,"analysis":33},933084,"某综合楼，建筑高度26m，总建筑面积为12000m2，室内全部设有湿式自动喷水灭火系统，系统选择直立型标准覆盖面积洒水喷头，则该系统应至少设置（ ）个湿式报警阀组。",[357,358,359,360],{"key":20,"text":349,"correct":22},{"key":24,"text":169,"correct":26},{"key":28,"text":25,"correct":22},{"key":31,"text":29,"correct":22},{"id":362,"libraryId":5,"type":15,"typeLabel":16,"stem":363,"options":364,"answer":31,"analysis":33},933085,"下列选项中，不属于湿式报警阀组组件的是（ ）。",[365,367,369,371],{"key":20,"text":366,"correct":22},"湿式报警阀",{"key":24,"text":368,"correct":22},"延迟器",{"key":28,"text":370,"correct":22},"水力警铃",{"key":31,"text":372,"correct":26},"水流指示器",{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":28,"analysis":33},933086,"防火分隔水幕洒水喷头的布置，应保证水幕的宽度不小于（ ）m。",[377,378,379,380],{"key":20,"text":169,"correct":22},{"key":24,"text":29,"correct":22},{"key":28,"text":105,"correct":26},{"key":31,"text":103,"correct":22},{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":24,"analysis":33},933087,"下列关于自动喷水灭火系统采用氯化聚氯乙烯管材及管件要满足条件的说法，错误的是（ ）。",[385,387,389,391],{"key":20,"text":386,"correct":22},"设置场所的火灾危险等级应为轻危险级或中危险级I级",{"key":24,"text":388,"correct":26},"系统应为湿式系统，并采用特殊响应洒水喷头",{"key":28,"text":390,"correct":22},"应用于公称直径不超过DN80的配水管及配水支管",{"key":31,"text":392,"correct":22},"不应穿越防火分区",{"id":394,"libraryId":5,"type":15,"typeLabel":16,"stem":395,"options":396,"answer":20,"analysis":33},933088,"某建筑高度为23．5m，耐火等级为一级，首层为商店营业厅，上部为办公，每层建筑面积为12000m2。建筑内全部采用不燃材料进行装修，并设置了湿式自动喷水灭火系统和火灾自动报警系统，该商店营业厅至少应设置（ ）个水流指示器。",[397,398,399,400],{"key":20,"text":169,"correct":26},{"key":24,"text":29,"correct":22},{"key":28,"text":105,"correct":22},{"key":31,"text":103,"correct":22},{"id":402,"libraryId":5,"type":15,"typeLabel":16,"stem":403,"options":404,"answer":20,"analysis":33},933089,"下列场所宜采用快速响应洒水喷头的是（ ）。",[405,407,409,411],{"key":20,"text":406,"correct":26},"设置在地上三层的KTV",{"key":24,"text":408,"correct":22},"设置在地上一层的展览馆",{"key":28,"text":410,"correct":22},"建筑高度为27m的办公楼",{"key":31,"text":234,"correct":22},{"id":413,"libraryId":5,"type":15,"typeLabel":16,"stem":414,"options":415,"answer":24,"analysis":33},933090,"下列有关防火分隔水幕喷头和防护冷却水幕喷头的说法，不正确的是（ ）。",[416,418,420,422],{"key":20,"text":417,"correct":22},"防护冷却水幕的喷头宜布置成单排",{"key":24,"text":419,"correct":26},"防火分隔水幕的喷头布置，应保证水幕的宽度不小于9m",{"key":28,"text":421,"correct":22},"防火分隔水幕采用水幕喷头时，喷头不应小于3排",{"key":31,"text":423,"correct":22},"防火分隔水幕采用开式洒水喷头时，喷头不应小于2排",{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":28,"analysis":33},933091,"某2层地上商店建筑，每层建筑面积为6000m2，所设置的自动喷水灭火系统应至少设置（ ）个水流指示器。",[428,429,430,431],{"key":20,"text":169,"correct":22},{"key":24,"text":25,"correct":22},{"key":28,"text":29,"correct":26},{"key":31,"text":173,"correct":22},{"id":433,"libraryId":5,"type":15,"typeLabel":16,"stem":434,"options":435,"answer":24,"analysis":33},933092,"某建筑高度为 33m 的公共建筑内，设置了湿式自动喷水灭火系统，该系统中一共设置了 3900 只喷头，则该湿式自动喷水灭火系统中至少应设置（ ）个湿式报警阀组。",[436,438,439,440],{"key":20,"text":437,"correct":22},"7",{"key":24,"text":173,"correct":26},{"key":28,"text":99,"correct":22},{"key":31,"text":25,"correct":22},{"id":442,"libraryId":5,"type":15,"typeLabel":16,"stem":443,"options":444,"answer":28,"analysis":33},933093,"某商业建筑，设置了预作用自动喷水灭火系统，共设计有3000个喷头保护吊顶下方空间。该建筑自动喷水灭火系统报警阀组的设置数量不应少于（ ）个。",[445,446,447,448],{"key":20,"text":169,"correct":22},{"key":24,"text":25,"correct":22},{"key":28,"text":29,"correct":26},{"key":31,"text":173,"correct":22},{"id":450,"libraryId":5,"type":15,"typeLabel":16,"stem":451,"options":452,"answer":24,"analysis":33},933094,"配水管道可采用内外壁热镀锌钢管、涂覆钢管、铜管、不锈钢管和氯化聚氯乙烯管，其工作压力不应大于（ ）MPa，并不应设置其他用水设施。",[453,454,455,456],{"key":20,"text":123,"correct":22},{"key":24,"text":65,"correct":26},{"key":28,"text":67,"correct":22},{"key":31,"text":169,"correct":22},{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":24,"analysis":33},933095,"同一场所内的喷头应布置在同一个平面上。直立型标准覆盖面积洒水喷头溅水盘与顶板的距离应在（ ）mm之间。",[461,463,465,467],{"key":20,"text":462,"correct":22},"75～100",{"key":24,"text":464,"correct":26},"75～150",{"key":28,"text":466,"correct":22},"100～150",{"key":31,"text":468,"correct":22},"150～300",{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":31,"analysis":33},933096,"某单层玩具厂房，室内净空高度为10m，设有湿式自动喷水灭火系统保护，其设计喷水强度不应小于（ ）L／minm2。",[473,474,475,476],{"key":20,"text":29,"correct":22},{"key":24,"text":105,"correct":22},{"key":28,"text":194,"correct":22},{"key":31,"text":477,"correct":26},"15",{"id":479,"libraryId":5,"type":15,"typeLabel":16,"stem":480,"options":481,"answer":31,"analysis":33},933097,"下列哪种场所不适合用雨淋灭火系统扑救（ ）。",[482,484,486,488],{"key":20,"text":483,"correct":22},"摄影棚",{"key":24,"text":485,"correct":22},"输煤栈桥转运站",{"key":28,"text":487,"correct":22},"易燃液体喷雾操作区域",{"key":31,"text":489,"correct":26},"图书馆书库",{"id":491,"libraryId":5,"type":15,"typeLabel":16,"stem":492,"options":493,"answer":31,"analysis":33},933098,"下列关于局部应用自动喷水灭火系统的说法中，不正确的是（）。",[494,496,498,500],{"key":20,"text":495,"correct":22},"应采用快速响应洒水喷头",{"key":24,"text":497,"correct":22},"保护区域总建筑面积不应超过1000m2",{"key":28,"text":499,"correct":22},"设置的场所应为轻危险级或中危险级Ⅰ级场所",{"key":31,"text":501,"correct":26},"应用于室内最大净空高度不超过8m的民用建筑和工业建筑",{"id":503,"libraryId":5,"type":15,"typeLabel":16,"stem":504,"options":505,"answer":31,"analysis":33},933099,"下列关于自动喷水灭火系统喷头选型的说法中，正确的是（）。",[506,508,510,512],{"key":20,"text":507,"correct":22},"对于湿式系统，不做吊顶的场所，当配水支管布置在梁下时，应采用下垂型洒水喷头",{"key":24,"text":509,"correct":22},"对于干式系统，应采用直立型洒水喷头或下垂型洒水喷头",{"key":28,"text":511,"correct":22},"对于湿式系统，吊顶下布置的洒水喷头，应采用吊顶型洒水喷头或干式下垂型洒水喷头",{"key":31,"text":513,"correct":26},"对于预作用系统，应采用直立型洒水喷头或干式下垂型洒水喷头",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":28,"analysis":33},933100,"某地上3层商场，设置采用自动喷水灭火系统保护，如果在设计中采用新型氯化聚氯乙烯管材及管件，则不能出现的情况是（）。",[518,520,522,524],{"key":20,"text":519,"correct":22},"商场的总建筑面积小于5000m2",{"key":24,"text":521,"correct":22},"系统为湿式自动喷水灭火系统",{"key":28,"text":523,"correct":26},"采用特殊响应洒水喷头",{"key":31,"text":525,"correct":22},"应用于管径不超过DN80的配水管或配水支管",{"id":527,"libraryId":5,"type":15,"typeLabel":16,"stem":528,"options":529,"answer":24,"analysis":33},933101,"某防火卷帘采用防护冷却系统保护，下列关于该系统的说法，正确的是（ ）。",[530,532,534,536],{"key":20,"text":531,"correct":22},"喷头的设置高度不应超过10m",{"key":24,"text":533,"correct":26},"喷头设置高度不超过4m时，喷水强度不应小于0．5L／（sm）",{"key":28,"text":535,"correct":22},"喷头的设置高度为5m时，系统应采用标准响应洒水喷头",{"key":31,"text":537,"correct":22},"喷头的溅水盘与防火卷帘的水平距离不应大于0．5m",{"id":539,"libraryId":5,"type":15,"typeLabel":16,"stem":540,"options":541,"answer":28,"analysis":33},933102,"某3层商场，每层净空高度为4．2m，总建筑面积为4800m2，采用由火灾自动报警系统和充气管道上设置的压力开关控制的预作用自动喷水灭火系统保护，则该系统的作用面积不应小于（ ）m2。",[542,543,544,545],{"key":20,"text":250,"correct":22},{"key":24,"text":246,"correct":22},{"key":28,"text":248,"correct":26},{"key":31,"text":546,"correct":22},"192",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":24,"analysis":33},933103,"某寒冷地区厂房，室内环境温度低于4℃，没有采暖设施，在设计时考虑采用自动喷水灭火系统保护，建设单位要求系统处于准工作状态时，严禁系统误喷，则该建筑设置自动喷水灭火系统时，宜采用（ ）系统。",[551,553,555,557],{"key":20,"text":552,"correct":22},"干式",{"key":24,"text":554,"correct":26},"预作用",{"key":28,"text":556,"correct":22},"水喷雾",{"key":31,"text":163,"correct":22},[559,562,565,568,571,574],{"id":15,"name":560,"category":7,"favorite":561},"领导干部任职前廉政法规知识测试题",92,{"id":563,"name":564,"category":7,"favorite":15},595,"建筑结构与设备",{"id":566,"name":567,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":569,"name":570,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":572,"name":573,"category":7,"favorite":8},534,"BIM工程师",{"id":575,"name":573,"category":7,"favorite":8},535]