[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-27":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":669},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,27,50,2960,[13,34,46,58,70,82,94,106,118,130,142,160,175,190,205,220,232,244,256,268,279,289,301,310,321,333,348,362,377,392,404,416,428,440,455,470,485,500,514,529,543,557,572,586,601,613,625,633,645,657],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},933004,1,"单选题","下列建筑中应设置消防电梯的是（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","某住宅建筑 11 层，层高 3.0m,首层室内地面标高为±0.000,室外地坪标高-0.600m",false,{"key":24,"text":25,"correct":22},"B","附设在高层建筑内第 5 层的总建筑面积 2800 ㎡的老年人照料设施",{"key":27,"text":28,"correct":22},"C","埋深为 8m 的地下建筑,地下建筑总面积为 5000 ㎡",{"key":30,"text":31,"correct":32},"D","建筑高度 34m 的综合楼",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},933005,"室外消火栓的保护半径在（ ）m左右，按规定一般设在城市道路两旁，故消防车道间距应为（ ）m。",[38,40,42,44],{"key":20,"text":39,"correct":22},"150，150",{"key":24,"text":41,"correct":32},"150，160",{"key":27,"text":43,"correct":22},"150，140",{"key":30,"text":45,"correct":22},"140，160",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":27,"analysis":33},933006,"建筑高度不大于50m的建筑，连续布置消防车登高操作场地有困难时，可间隔布置，但间隔距离不宜大于（ ）m。",[50,52,54,56],{"key":20,"text":51,"correct":22},"20",{"key":24,"text":53,"correct":22},"25",{"key":27,"text":55,"correct":32},"30",{"key":30,"text":57,"correct":22},"35",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},933007,"消防电梯井与相邻电梯井之间应设置耐火极限不低于（ ）h的防火隔墙，隔墙上的门应采用（ ）防火门。",[62,64,66,68],{"key":20,"text":63,"correct":22},"3．0，乙级",{"key":24,"text":65,"correct":22},"1．5，甲级",{"key":27,"text":67,"correct":32},"2．0，甲级",{"key":30,"text":69,"correct":22},"2．5，乙级",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},933008,"某建筑高度为58m的高层建筑，其裙房建筑高度为16m，当消防车登高操作场地沿该建筑长边设置时，该范围内的裙房进深不应大于（ ）m。",[74,76,78,80],{"key":20,"text":75,"correct":32},"4",{"key":24,"text":77,"correct":22},"5",{"key":27,"text":79,"correct":22},"6",{"key":30,"text":81,"correct":22},"8",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":27,"analysis":33},933009,"下列有关建筑救援场地设置的说法中，错误的是（ ）。",[86,88,90,92],{"key":20,"text":87,"correct":22},"对于建筑高度大于50m的建筑，场地的长度和宽度分别不应小于20m和10m",{"key":24,"text":89,"correct":22},"救援场地的坡度不宜大于3%",{"key":27,"text":91,"correct":32},"场地及其下面的建筑结构、管道和暗沟等，应能承受消防车的压力",{"key":30,"text":93,"correct":22},"建筑物与消防车登高操作场地相对应的范围内，应设置直通室外的楼梯或直通楼梯间的入口",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":30,"analysis":33},933010,"某住宅建筑，二级耐火等级，室内设计地面标高为±0．000m，室外设计地面标高-0．700m，平屋面面层标高50．600m，矩形平面尺寸为60m×40m，沿建筑周边设置环形消防车道，下列关于布置消防救援场地的说法，正确的是（ ）。",[98,100,102,104],{"key":20,"text":99,"correct":22},"可间隔布置，但间隔距离不宜大于10m",{"key":24,"text":101,"correct":22},"可间隔布置，但间隔距离不宜大于30m",{"key":27,"text":103,"correct":22},"可间隔布置，但间隔距离不宜大于40m",{"key":30,"text":105,"correct":32},"不可间隔布置",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":30,"analysis":33},933011,"某一级耐火等级宾馆，建筑高度52m，东西长80m，南北宽60m。下列关于该酒店消防车登高操作场地布置的做法，正确的是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"消防车登高操作场地与该建筑之间种有一排橡树",{"key":24,"text":113,"correct":22},"消防车登高操作场地下面的建筑结构、管道和暗沟可以承受普通消防车的压力",{"key":27,"text":115,"correct":22},"消防车登高操作场地与宾馆建筑外墙的边缘距离为12m",{"key":30,"text":117,"correct":32},"该建筑消防车登高操作场地的坡度为1％",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":30,"analysis":33},933012,"下列关于消防电梯设置要求的说法错误的是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":22},"消防电梯应分别设置在不同防火分区内，且每个防火分区不应少于1台",{"key":24,"text":125,"correct":22},"消防电梯应设置前室或与防烟楼梯间合用的前室",{"key":27,"text":127,"correct":22},"消防电梯井、机房与相邻电梯井、机房之间应设置耐火极限不低于2．00h的防火隔墙",{"key":30,"text":129,"correct":32},"电梯轿厢的内部装修应采用难燃材料",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":27,"analysis":33},933013,"下列有关消防电梯设置规定的说法中，错误的是（ ）。",[134,136,138,140],{"key":20,"text":135,"correct":22},"消防电梯应能每层停靠",{"key":24,"text":137,"correct":22},"电梯从首层至顶层的运行时间不宜大于1min",{"key":27,"text":139,"correct":32},"在各层的消防电梯入口处应设置供消防队员专用的操作按钮",{"key":30,"text":141,"correct":22},"电梯轿厢的内部装修应采用不燃材料",{"id":143,"libraryId":5,"type":144,"typeLabel":145,"stem":146,"options":147,"answer":159,"analysis":33},933014,2,"多选题","下列关于消防电梯前室的做法，错误的是（ ）。",[148,150,152,154,156],{"key":20,"text":149,"correct":32},"某住宅建筑设置消防电梯前室其前室的使用面积为4．5m2",{"key":24,"text":151,"correct":22},"某公共建筑设置消防电梯前室，其前室的使用面积为6．0m2，且短边不应小于2.4m",{"key":27,"text":153,"correct":32},"某住宅建筑设置剪刀楼梯间共用前室与消防电梯的前室合用的使用面积为12．0m2",{"key":30,"text":155,"correct":32},"某公共建筑设置剪刀楼梯间共用前室与消防电梯的前室的使用面积为12．0m2",{"key":157,"text":158,"correct":32},"E","某仓库的消防电梯前室设置耐火极限为3．00h的防火卷帘","ACDE",{"id":161,"libraryId":5,"type":144,"typeLabel":145,"stem":162,"options":163,"answer":174,"analysis":33},933015,"某一级耐火等级的服装加工厂房，地上6层，层高6m，每层建筑面积为5000m2，消防电梯前室独立设置，并按照现行国家规定设置了相应的消防设施：下列关于消防电梯的做法，不符合规范要求的是（）。",[164,166,168,170,172],{"key":20,"text":165,"correct":32},"前室使用面积为4．5m2",{"key":24,"text":167,"correct":22},"设置1台消防电梯",{"key":27,"text":169,"correct":22},"在前室人口处设置乙级防火门",{"key":30,"text":171,"correct":32},"首层前室通过35m的通道通向室外",{"key":157,"text":173,"correct":22},"消防电梯兼做货梯","AD",{"id":176,"libraryId":5,"type":144,"typeLabel":145,"stem":177,"options":178,"answer":189,"analysis":33},933016,"对于高层建筑，设置消防电梯能节省消防员的体力，使消防员能快速接近着火区域，提高战斗力和灭火救援效果。下列需要设置消防电梯的有（ ）。",[179,181,183,185,187],{"key":20,"text":180,"correct":32},"建筑高度为45m的住宅建筑",{"key":24,"text":182,"correct":32},"建筑高度为25m的门诊楼",{"key":27,"text":184,"correct":32},"建筑高度为33m的公寓",{"key":30,"text":186,"correct":32},"建筑高度为51m的写字楼",{"key":157,"text":188,"correct":22},"埋深12m且总建筑面积为2500m2的地下商场","ABCD",{"id":191,"libraryId":5,"type":144,"typeLabel":145,"stem":192,"options":193,"answer":204,"analysis":33},933017,"下列建筑中，可不设消防电梯的有（ ）。",[194,196,198,200,202],{"key":20,"text":195,"correct":22},"某建筑高度为27m医院，每层建筑面积500m2",{"key":24,"text":197,"correct":32},"某综合楼建筑高度25m，每层建筑面积1600m2",{"key":27,"text":199,"correct":22},"某建筑高度为52m办公楼的地下汽车库，地下2层，层高4m",{"key":30,"text":201,"correct":32},"某独立建造的商场，地下2层，层高4m，每层建筑面积2000m2",{"key":157,"text":203,"correct":32},"某底部为商业服务网点的住宅，建筑高度32m，每层建筑面积6000m2","BDE",{"id":206,"libraryId":5,"type":144,"typeLabel":145,"stem":207,"options":208,"answer":219,"analysis":33},933018,"某综合楼，地上14层，层高4m，长和宽分别为120m、80m，地下设置了两层汽车库，该综合楼北面一侧为城市主路，主路两侧均种有梧桐树，西侧为配电室。下列关于该办公楼消防车登高操作场地的设计，符合规范要求的有（）。",[209,211,213,215,217],{"key":20,"text":210,"correct":22},"消防车登高操作场地沿建筑北侧和西侧间隔布置布置间距为5m",{"key":24,"text":212,"correct":22},"消防车登高操作场地距建筑外墙的距离为4m-8m",{"key":27,"text":214,"correct":32},"消防车登高操作场地的坡度为2％",{"key":30,"text":216,"correct":32},"消防车登高操作场地宽度为13m",{"key":157,"text":218,"correct":32},"消防车登高操作场的长度为130m","CDE",{"id":221,"libraryId":5,"type":15,"typeLabel":16,"stem":222,"options":223,"answer":24,"analysis":33},933019,"下列关于环形消防车道的说法，不正确的是（ ）。",[224,226,228,230],{"key":20,"text":225,"correct":22},"高度高、体量大、功能复杂、扑救困难的建筑应设环形消防车道",{"key":24,"text":227,"correct":32},"设置环形消防车道有困难时，可以沿着建筑两边设置消防车道",{"key":27,"text":229,"correct":22},"高层住宅建筑，可以沿建筑一个长边设置消防车道",{"key":30,"text":231,"correct":22},"环形消防车道至少有两处与其他车道连通",{"id":233,"libraryId":5,"type":15,"typeLabel":16,"stem":234,"options":235,"answer":30,"analysis":33},933020,"下列工业建筑中，应设置环形消防车道的有（ ）。",[236,238,240,242],{"key":20,"text":237,"correct":22},"占地面积为2000m2的镁粉厂",{"key":24,"text":239,"correct":22},"占地面积为2000m2的石棉加工厂房",{"key":27,"text":241,"correct":22},"占地面积为2000m2的造纸备料厂",{"key":30,"text":243,"correct":32},"占地面积为2000m2的油纸仓",{"id":245,"libraryId":5,"type":15,"typeLabel":16,"stem":246,"options":247,"answer":27,"analysis":33},933021,"下列关于设置消防车道的说法，不正确的是（ ）。",[248,250,252,254],{"key":20,"text":249,"correct":22},"L形建筑总长度260m，可以设置穿过建筑的消防车道",{"key":24,"text":251,"correct":22},"建筑高度27m的办公楼，可以设置环形型消防车道",{"key":27,"text":253,"correct":32},"某建筑高度28m的住宅建筑，沿河道边临空建造，沿建筑的一个短边设置消防车道",{"key":30,"text":255,"correct":22},"占地面积为4000m2的展览馆，确有困难时，可沿建筑的两个长边设置两条消防车道",{"id":257,"libraryId":5,"type":15,"typeLabel":16,"stem":258,"options":259,"answer":24,"analysis":33},933022,"某建筑高度为34m的办公楼，设有尽头式消防车道，并设置回车场，回车场的面积不宜小于（ ）。",[260,262,264,266],{"key":20,"text":261,"correct":22},"12m×12m",{"key":24,"text":263,"correct":32},"15m×15m",{"key":27,"text":265,"correct":22},"18m×18m",{"key":30,"text":267,"correct":22},"20m×10m",{"id":269,"libraryId":5,"type":15,"typeLabel":16,"stem":270,"options":271,"answer":24,"analysis":33},933023,"某建筑高度为82m的综合楼，无裙房，矩形平面尺寸为150m×80m，沿该建筑的一个长边和短边连续布置宽度为10m的消防车登高操作场地，沿长边布置的消防车登高操作场地的最小平面尺寸是（ ）。",[272,273,275,277],{"key":20,"text":267,"correct":22},{"key":24,"text":274,"correct":32},"70m×10m",{"key":27,"text":276,"correct":22},"80m×10m",{"key":30,"text":278,"correct":22},"150m×10m",{"id":280,"libraryId":5,"type":15,"typeLabel":16,"stem":281,"options":282,"answer":30,"analysis":33},933024,"某新建建筑高度为27m的办公建筑，正方形布置，尺寸为70m×70m，连续布置消防车登高操作场地确有困难。当间隔布置为平面尺寸15m×15m的登高操作场地时，应至少布置（ ）个。",[283,285,287,288],{"key":20,"text":284,"correct":22},"2",{"key":24,"text":286,"correct":22},"3",{"key":27,"text":75,"correct":22},{"key":30,"text":77,"correct":32},{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":20,"analysis":33},933025,"下列关于供消防救援人员进入建筑内的救援窗口的说法，错误的是（ ）。",[293,295,297,299],{"key":20,"text":294,"correct":32},"救援窗的玻璃应采用钢化防火防撞击玻璃",{"key":24,"text":296,"correct":22},"救援窗口的下沿距室内地面高度不宜大于1．2m",{"key":27,"text":298,"correct":22},"救援窗口位置应与消防车登高操作场地相对应",{"key":30,"text":300,"correct":22},"救援窗口间距不宜大于20m且每个防火分区不应少于2个",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":27,"analysis":33},933026,"尽头式消防车道应根据消防车辆的回转需要设置回车道或回车场，供重型消防车使用的回车场不宜小于（ ）。",[305,306,307,308],{"key":20,"text":261,"correct":22},{"key":24,"text":263,"correct":22},{"key":27,"text":265,"correct":32},{"key":30,"text":309,"correct":22},"9m×9m",{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":30,"analysis":33},933027,"对于公共建筑而言，消防电梯与防烟楼梯间合用前室的使用面积不应小于（ ）m2。",[314,316,317,319],{"key":20,"text":315,"correct":22},"4．5",{"key":24,"text":79,"correct":22},{"key":27,"text":318,"correct":22},"9",{"key":30,"text":320,"correct":32},"10",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":27,"analysis":33},933028,"高度高、体量大、功能复杂、扑救困难的建筑应设（ ）消防车道。",[325,327,329,331],{"key":20,"text":326,"correct":22},"方形",{"key":24,"text":328,"correct":22},"长条形",{"key":27,"text":330,"correct":32},"环形",{"key":30,"text":332,"correct":22},"尽头式",{"id":334,"libraryId":5,"type":144,"typeLabel":145,"stem":335,"options":336,"answer":347,"analysis":33},933029,"下列建筑中，应设置环形消防车道的有（ ）。",[337,339,341,343,345],{"key":20,"text":338,"correct":22},"某建筑高度为24m的住宅",{"key":24,"text":340,"correct":32},"某建筑高度为27m的公寓",{"key":27,"text":342,"correct":22},"某地上3层的商场，占地面积2000m2",{"key":30,"text":344,"correct":32},"某单层展览馆，占地面积6000m2",{"key":157,"text":346,"correct":22},"某木材厂占地面积2500m2","BD",{"id":349,"libraryId":5,"type":144,"typeLabel":145,"stem":350,"options":351,"answer":174,"analysis":33},933030,"下列关于消防电梯的说法，错误的是（ ）。",[352,354,356,358,360],{"key":20,"text":353,"correct":32},"消防电梯从首层至顶层的运行时间不宜大于2min",{"key":24,"text":355,"correct":22},"消防电梯应能每层都停靠",{"key":27,"text":357,"correct":22},"消防电梯的载重量不应小于800kg",{"key":30,"text":359,"correct":32},"消防电梯的井底应设置排水设施，排水井的容量不应大于2m3",{"key":157,"text":361,"correct":22},"消防电梯在首层的消防电梯入口处应设置供消防队员专用的操作按钮",{"id":363,"libraryId":5,"type":144,"typeLabel":145,"stem":364,"options":365,"answer":376,"analysis":33},933031,"关于消防电梯的设置范围，正确的是（ ）。",[366,368,370,372,374],{"key":20,"text":367,"correct":22},"建筑高度大于32m的住宅建筑应设消防电梯",{"key":24,"text":369,"correct":32},"一类高层公共建筑和建筑高度大于32m的二类高层公共建筑应设消防电梯",{"key":27,"text":371,"correct":32},"设置消防电梯的建筑的地下或半地下室，埋深大于10m且总建筑面积大于3000m2的其他地下或半地下建筑（室）应设消防电梯",{"key":30,"text":373,"correct":22},"建筑高度大于32m且设置电梯，任一层工作平台上的人数不超过3人的高层塔架可不设消防电梯",{"key":157,"text":375,"correct":32},"局部建筑高度大于32m，且局部高出部分的每层建筑面积不大于50m2的丁、戊类厂房可不设消防电梯","BCE",{"id":378,"libraryId":5,"type":144,"typeLabel":145,"stem":379,"options":380,"answer":391,"analysis":33},933032,"消防电梯的设置范围包括（ ）。",[381,383,385,387,389],{"key":20,"text":382,"correct":22},"建筑高度大于32m的住宅建筑",{"key":24,"text":384,"correct":32},"一类高层公共建筑和建筑高度大于32m的二类高层公共建筑",{"key":27,"text":386,"correct":32},"埋深大于10m且总建筑面积大于3000m2的地下或半地下建筑（室）",{"key":30,"text":388,"correct":22},"局部建筑高度大于32m，且局部高出部分的每层建筑面积不大于50m2的丁、戊类厂房",{"key":157,"text":390,"correct":22},"建筑高度大于32m且设置电梯，任一层工作平台上的人数不超过2人的高层塔架","BC",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":30,"analysis":33},933033,"下列不属于安全疏散设施的是（ ）。",[396,398,400,402],{"key":20,"text":397,"correct":22},"消防应急照明",{"key":24,"text":399,"correct":22},"疏散走道",{"key":27,"text":401,"correct":22},"屋顶直升机停机坪",{"key":30,"text":403,"correct":32},"自动扶梯",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":24,"analysis":33},933034,"下列不属于移动式灭火器材的是（ ）。",[408,410,412,414],{"key":20,"text":409,"correct":22},"消防斧",{"key":24,"text":411,"correct":32},"消防电梯",{"key":27,"text":413,"correct":22},"灭火器",{"key":30,"text":415,"correct":22},"安全锤",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":27,"analysis":33},933035,"建筑消防设施的使用、管理单位在受建筑消防设施的产权单位全部或局部委托或转让、租赁时，应明确建筑消防设施的日常管理责任。下列选项中不属于使用、管理单位日常管理职责的是（ ）。",[420,422,424,426],{"key":20,"text":421,"correct":22},"制定建筑消防设施管理制度和操作规程",{"key":24,"text":423,"correct":22},"建立建筑消防设施配置、运行等情况的管理档案",{"key":27,"text":425,"correct":32},"根据消防法规的规定建立专职消防队、义务消防队",{"key":30,"text":427,"correct":22},"明确专门部门和专人负责建筑消防设施的操作、检查和维护保养工作",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":30,"analysis":33},933036,"对建筑消防设施履行日常管理责任的是（ ）。",[432,434,436,438],{"key":20,"text":433,"correct":22},"各级人民政府",{"key":24,"text":435,"correct":22},"行政管理部门",{"key":27,"text":437,"correct":22},"消防机构",{"key":30,"text":439,"correct":32},"建筑消防设施的产权单位",{"id":441,"libraryId":5,"type":144,"typeLabel":145,"stem":442,"options":443,"answer":454,"analysis":33},933037,"下列关于自动喷水灭火系统操作控制的说法，正确的是（ ）。",[444,446,448,450,452],{"key":20,"text":445,"correct":32},"消防水泵除具有自动控制启动方式外，还应具备消防控制室（盘）远程控制和消防水泵房现场应急操作",{"key":24,"text":447,"correct":22},"干式系统应由消防水泵出水干管上设置的压力开关或火灾自动报警系统直接启动消防水泵",{"key":27,"text":449,"correct":22},"湿式系统应由高位消防水箱出水管上的流量开关或火灾自动报警系统直接启动消防水泵",{"key":30,"text":451,"correct":32},"快速排气阀入口前的电动阀应在启动消防水泵的同时开启",{"key":157,"text":453,"correct":32},"预作用装置处应设置现场手动应急操作","ADE",{"id":456,"libraryId":5,"type":144,"typeLabel":145,"stem":457,"options":458,"answer":469,"analysis":33},933038,"某综合楼设置了湿式自动喷水灭火系统进行保护，系统采用直立型喷头，下列关于喷头安装的说法中，符合现行国家消防技术标准的有（ ）。",[459,461,463,465,467],{"key":20,"text":460,"correct":32},"无梁或其他障碍物时，溅水盘与顶板的距离，不应小于75mm，不应大于150mm",{"key":24,"text":462,"correct":22},"有梁或其他障碍物时，溅水盘与顶板的距离，不应大于250mm",{"key":27,"text":464,"correct":32},"当在梁或其他障碍物底面下方的平面上布置洒水喷头时，溅水盘与顶板的距离不应大于300mm，同时溅水盘与梁等障碍物底面的垂直距离应为25mm~100mm",{"key":30,"text":466,"correct":22},"密肋梁板下方的喷头，溅水盘与密肋梁板底面的垂直距离，不应小于50mm，不应大于100mm",{"key":157,"text":468,"correct":32},"在梁间布置的喷头，确有困难时，溅水盘与顶板的距离，不应大于550mm","ACE",{"id":471,"libraryId":5,"type":144,"typeLabel":145,"stem":472,"options":473,"answer":484,"analysis":33},933039,"可采用闭式喷头的自动灭火系统有（ ）。",[474,476,478,480,482],{"key":20,"text":475,"correct":32},"湿式自动喷水灭火系统",{"key":24,"text":477,"correct":32},"干式自动喷水灭火系统",{"key":27,"text":479,"correct":22},"雨淋灭火系统",{"key":30,"text":481,"correct":22},"水幕系统",{"key":157,"text":483,"correct":32},"细水雾灭火系统","ABE",{"id":486,"libraryId":5,"type":144,"typeLabel":145,"stem":487,"options":488,"answer":499,"analysis":33},933040,"下列选项中，属于自动喷水灭火系统中火灾危险等级中危Ⅱ级的有（ ）。",[489,491,493,495,497],{"key":20,"text":490,"correct":32},"书库",{"key":24,"text":492,"correct":22},"舞台葡萄架部分",{"key":27,"text":494,"correct":32},"总建筑面积的1000m2的地下商场",{"key":30,"text":496,"correct":22},"印刷厂",{"key":157,"text":498,"correct":22},"24m高的旅馆","AC",{"id":501,"libraryId":5,"type":144,"typeLabel":145,"stem":502,"options":503,"answer":499,"analysis":33},933041,"下列关于自动喷水灭火系统的说法，正确的有（ ）。",[504,506,508,510,512],{"key":20,"text":505,"correct":32},"湿式系统应在开放1只洒水喷头后自动启动",{"key":24,"text":507,"correct":22},"露天场所不宜采用开式系统",{"key":27,"text":509,"correct":32},"局部应用系统的持续喷水时间不应低于0．5h",{"key":30,"text":511,"correct":22},"预作用系统在满足相应的条件时，可以采用氯化聚氯乙烯管材或管件",{"key":157,"text":513,"correct":22},"自动喷水灭火系统可与消火栓系统合用高位消防水箱",{"id":515,"libraryId":5,"type":144,"typeLabel":145,"stem":516,"options":517,"answer":528,"analysis":33},933042,"下列哪些场所宜采用快速响应喷头（ ）。",[518,520,522,524,526],{"key":20,"text":519,"correct":32},"设置在建筑首层的KTV",{"key":24,"text":521,"correct":32},"建筑面积3000m2的商场中部设置的中庭环廊",{"key":27,"text":523,"correct":32},"建筑高度为18m的病房楼",{"key":30,"text":525,"correct":22},"建筑高度为30m旅馆",{"key":157,"text":527,"correct":32},"幼儿园","ABCE",{"id":530,"libraryId":5,"type":144,"typeLabel":145,"stem":531,"options":532,"answer":484,"analysis":33},933043,"下列关于自动喷水灭火系统报警阀组的说法，错误的是（ ）。",[533,535,537,539,541],{"key":20,"text":534,"correct":32},"报警阀组设置在专用的报警阀室，设置点的环境温度为0℃",{"key":24,"text":536,"correct":32},"某建筑高度60m，地下一层，地上20层，每层均设置自动喷水灭火系统，一个报警阀组设置在地下一层",{"key":27,"text":538,"correct":22},"水幕系统应设置独立的报警阀组或感温雨淋阀",{"key":30,"text":540,"correct":22},"当闭式系统保护室内钢屋架时，应单独设置独立报警阀组，不可合用",{"key":157,"text":542,"correct":32},"某货架仓库设置自动喷水灭火系统，顶板下喷头与货架内共设置一个水流指示器",{"id":544,"libraryId":5,"type":144,"typeLabel":145,"stem":545,"options":546,"answer":376,"analysis":33},933044,"对于采用充液传动管直接控制的雨淋系统，可以直接自动启动消防水泵的是（）。",[547,549,551,553,555],{"key":20,"text":548,"correct":22},"感烟火灾探测器",{"key":24,"text":550,"correct":32},"高位水箱出水管上设置的流量开关",{"key":27,"text":552,"correct":32},"消防水泵出水干管上设置的压力开关",{"key":30,"text":554,"correct":22},"水流指示器",{"key":157,"text":556,"correct":32},"雨淋报警阀组上设置的压力开关",{"id":558,"libraryId":5,"type":144,"typeLabel":145,"stem":559,"options":560,"answer":571,"analysis":33},933045,"某建筑采用预作用自动喷水灭火系统保护，系统采用火灾自动报警系统和充气管道上设置的压力开关控制，下列关于该系统的说法中，不正确的是（）。",[561,563,565,567,569],{"key":20,"text":562,"correct":22},"系统适用于准工作状态时严禁管道充水的场所",{"key":24,"text":564,"correct":32},"系统配水管道冲水时间不宜大于2min",{"key":27,"text":566,"correct":32},"系统配水管道上应设置自动排气阀",{"key":30,"text":568,"correct":32},"系统的喷水强度和作用面积应按相应规定值的1．3倍确定",{"key":157,"text":570,"correct":22},"系统应采用直立型洒水喷头或干式下垂型洒水喷头","BCD",{"id":573,"libraryId":5,"type":144,"typeLabel":145,"stem":574,"options":575,"answer":469,"analysis":33},933046,"下列场所场所应设置自动喷水灭火系统的是（）。",[576,578,580,582,584],{"key":20,"text":577,"correct":32},"建筑高度12m总高3层，占地面积1600㎡的木器厂房",{"key":24,"text":579,"correct":22},"建筑高度12m总高3层，占地面积600㎡的火柴仓库",{"key":27,"text":581,"correct":32},"建筑高度12m总高3层，藏书量为60万册的图书馆",{"key":30,"text":583,"correct":22},"建筑高度12m总高3层，每层的建筑面积200㎡的地上歌舞娱乐放映游艺场所",{"key":157,"text":585,"correct":32},"建筑高度12m总高3层，占地面积300㎡的大型幼儿园",{"id":587,"libraryId":5,"type":144,"typeLabel":145,"stem":588,"options":589,"answer":600,"analysis":33},933047,"某地下2层商场，每层建筑面积为2500m2，室内最大净空高度为4．8m，建筑内全部设置湿式自动喷水灭火系统，下列关于该自动喷水灭火系统的做法中，不正确的是（ ）。",[590,592,594,596,598],{"key":20,"text":591,"correct":22},"系统采用快速响应洒水喷头",{"key":24,"text":593,"correct":32},"系统的喷水强度为6L／min·m2",{"key":27,"text":595,"correct":32},"洒水喷头与配水管道采用消防洒水软管连接",{"key":30,"text":597,"correct":32},"部分场所采用隐蔽式洒水喷头",{"key":157,"text":599,"correct":32},"商场通道上方设有喷头，喷头的上方设有挡水板","BCDE",{"id":602,"libraryId":5,"type":15,"typeLabel":16,"stem":603,"options":604,"answer":30,"analysis":33},933048,"下列不属于防护冷却系统和防护冷却水幕系统不同之处的是（ ）。",[605,607,609,611],{"key":20,"text":606,"correct":22},"使用的喷头类型不同",{"key":24,"text":608,"correct":22},"防护冷却系统是闭式系统，防护冷却水幕系统是开式系统",{"key":27,"text":610,"correct":22},"喷头最大设置点高度不同",{"key":30,"text":612,"correct":32},"持续喷水时间都与被保护部位的耐火极限有关",{"id":614,"libraryId":5,"type":15,"typeLabel":16,"stem":615,"options":616,"answer":20,"analysis":33},933049,"下列关于自动喷水灭火系统适用范围的说法中，错误的是（ ）。",[617,619,621,623],{"key":20,"text":618,"correct":32},"室内净空高度超过一定高度且必须迅速扑救的初期火灾和属于中危险级Ⅱ级及以上的场所应采用雨淋系统",{"key":24,"text":620,"correct":22},"湿式系统适合在环境温度不低于4℃且不高于70℃的环境中使用",{"key":27,"text":622,"correct":22},"严禁系统误喷的忌水场所应采用预作用系统",{"key":30,"text":624,"correct":22},"干式系统可以适用于环境温度高于70℃的场所",{"id":626,"libraryId":5,"type":15,"typeLabel":16,"stem":627,"options":628,"answer":24,"analysis":33},933050,"某场所设置局部应用湿式自动喷水灭火系统，采用扩大覆盖面积洒水喷头，系统作用面积内开放喷头数量应按不少于（ ）只确定。",[629,630,631,632],{"key":20,"text":77,"correct":22},{"key":24,"text":79,"correct":32},{"key":27,"text":81,"correct":22},{"key":30,"text":320,"correct":22},{"id":634,"libraryId":5,"type":15,"typeLabel":16,"stem":635,"options":636,"answer":30,"analysis":33},933051,"下列有关报警阀组设置要求的说法，正确的是（ ）。",[637,639,641,643],{"key":20,"text":638,"correct":22},"报警阀组宜设在安全及易于操作的地点，报警阀距地面的高度宜为1．1m",{"key":24,"text":640,"correct":22},"连接报警阀进出口的控制阀应采用蝶阀",{"key":27,"text":642,"correct":22},"并联设置雨淋阀组的雨淋系统，其雨淋阀控制腔的入口应设明杆闸阀",{"key":30,"text":644,"correct":32},"安装报警阀的部位应设有排水设施",{"id":646,"libraryId":5,"type":15,"typeLabel":16,"stem":647,"options":648,"answer":27,"analysis":33},933052,"下列有关末端试水装置的说法中，正确的是（ ）。",[649,651,653,655],{"key":20,"text":650,"correct":22},"试水接头出水口的流量系数，应等同于同楼层或防火分区内的最大流量系数喷头",{"key":24,"text":652,"correct":22},"末端试水装置应由试水阀、压力表、水流指示器以及试水接头组成",{"key":27,"text":654,"correct":32},"每个报警阀组控制的最不利点喷头处应设末端试水装置",{"key":30,"text":656,"correct":22},"末端试水装置连接管的管径不应小于20mm",{"id":658,"libraryId":5,"type":15,"typeLabel":16,"stem":659,"options":660,"answer":20,"analysis":33},933053,"在密肋梁板下安装直立型扩大覆盖面积洒水喷头时，溅水盘与密肋梁板底面的垂直距离应为（ ）。",[661,663,665,667],{"key":20,"text":662,"correct":32},"25mm～100mm",{"key":24,"text":664,"correct":22},"50mm～100mm",{"key":27,"text":666,"correct":22},"50mm～150mm",{"key":30,"text":668,"correct":22},"100mm～250mm",[670,673,676,679,682,685],{"id":15,"name":671,"category":7,"favorite":672},"领导干部任职前廉政法规知识测试题",92,{"id":674,"name":675,"category":7,"favorite":15},595,"建筑结构与设备",{"id":677,"name":678,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":680,"name":681,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":683,"name":684,"category":7,"favorite":8},534,"BIM工程师",{"id":686,"name":684,"category":7,"favorite":8},535]