[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-26":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":623},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,26,50,2960,[13,34,46,58,70,81,93,104,116,128,140,148,160,168,178,186,198,210,228,243,258,272,287,302,316,326,337,349,357,369,381,392,404,416,428,436,451,466,480,495,506,518,530,542,554,566,578,587,599,611],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},932952,1,"单选题","下列关于建筑设置基层墙体与装饰层之间无空腔的建筑外墙体外保温系统的做法中，不符合现行国家消防技术标准的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","建筑高度为18m的图书馆，保温系统采用燃烧性能为B1级的保温材料",true,{"key":24,"text":25,"correct":26},"B","建筑高度为27m设置商业服务网点的住宅，保温系统采用燃烧性能为B2级的保温材料",false,{"key":28,"text":29,"correct":26},"C","建筑高度为60m的办公楼，保温系统采用燃烧性能为A级的保温材料",{"key":31,"text":32,"correct":26},"D","建筑高度为50m的办公楼，保温系统采用燃烧性能为B1级的保温材料","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":20,"analysis":33},932954,"某歌舞厅，设置在一级耐火等级建筑的地下一层，则其室内装修的做法符合规范最低要求的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"顶棚采用A级装修材料，墙面采用A级装修材料",{"key":24,"text":41,"correct":26},"顶棚采用A级装修材料，墙面采用B1级装修材料",{"key":28,"text":43,"correct":26},"顶棚采用B1级装修材料，地面采用A级装修材料",{"key":31,"text":45,"correct":26},"顶棚采用B1级装修材料，地面采用B1级装修材料",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":20,"analysis":33},932955,"下列关于建筑内特殊功能部位和用房装修防火要求的说法，错误的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"消防控制室的顶棚、墙面、地面均应采用A级装修材料",{"key":24,"text":53,"correct":26},"建筑内厨房的顶棚、墙面、地面均应采用A级装修材料",{"key":28,"text":55,"correct":26},"疏散楼梯间和前室的顶棚、墙面、地面均应采用A级装修材料",{"key":31,"text":57,"correct":26},"消防水泵房的顶棚、墙面、地面均应采用A级装修材料",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},932956,"下列关于建筑内部装修防火的说法，不符合规定的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":26},"地上疏散走道的顶棚装修材料必须采用A级装修材料",{"key":24,"text":65,"correct":26},"地下疏散走道的墙面装修材料必须采用A级装修材料",{"key":28,"text":67,"correct":22},"变形缝两侧基层的表面装修材料必须采用A级装修材料",{"key":31,"text":69,"correct":26},"地上安全出口的门厅顶棚装修材料必须采用A级装修材料",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},932957,"某一级耐火等级的宾馆，建筑高度56m，每层建筑面积6000m2，采用自动喷水灭火系统和火灾自动报警系统保护，则该宾馆房间的顶棚应采用燃烧性能不低于（ ）级的材料装修。",[74,75,77,79],{"key":20,"text":20,"correct":22},{"key":24,"text":76,"correct":26},"B1",{"key":28,"text":78,"correct":26},"B2",{"key":31,"text":80,"correct":26},"B3",{"id":82,"libraryId":5,"type":15,"typeLabel":16,"stem":83,"options":84,"answer":24,"analysis":33},932958,"当建筑外墙的内保温系统采用燃烧性能等级为B1级的保温材料时，其防护层的厚度不应小于（ ）mm。",[85,87,89,91],{"key":20,"text":86,"correct":26},"5",{"key":24,"text":88,"correct":22},"10",{"key":28,"text":90,"correct":26},"20",{"key":31,"text":92,"correct":26},"50",{"id":94,"libraryId":5,"type":15,"typeLabel":16,"stem":95,"options":96,"answer":28,"analysis":33},932959,"建筑外墙的装饰层应采用燃烧性能为A级的材料，但建筑高度不大于（ ）m时，可采用B1级材料。",[97,99,101,102],{"key":20,"text":98,"correct":26},"27",{"key":24,"text":100,"correct":26},"24",{"key":28,"text":92,"correct":22},{"key":31,"text":103,"correct":26},"100",{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":28,"analysis":33},932960,"办公建筑，建筑高度为48m，耐火等级为二级，屋面板的耐火极限为1.00h，采用与基层墙体、装饰层之间无空腔的建筑外墙外保温系统，其中外墙保温材料的燃烧性能为B1级，屋面保温材料的燃烧性能为B2。下列有关该建筑外保温系统的说法中，错误的是（ ）。",[108,110,112,114],{"key":20,"text":109,"correct":26},"建筑外墙上门、窗的耐火完整性不应低于0.50h",{"key":24,"text":111,"correct":26},"应在保温系统中每层设置防火隔离带，防火隔离带的高度不应小于300mm",{"key":28,"text":113,"correct":22},"屋面与外墙之间应采用宽度不小于450mm的不燃材料设置防火隔离带进行分隔",{"key":31,"text":115,"correct":26},"应在保温系统中每层设置防火隔离带，防火隔离带所用材料的燃烧性能应为A级",{"id":117,"libraryId":5,"type":15,"typeLabel":16,"stem":118,"options":119,"answer":31,"analysis":33},932961,"下列关于与基层墙体、装饰层之间无空腔的建筑外墙外保温系统的说法，错误的是（）。",[120,122,124,126],{"key":20,"text":121,"correct":26},"建筑高度为100m的住宅建筑采用B1级保温材料时，外墙上门、窗的耐火完整性不应低于0．50h且每层应设置防火隔离带",{"key":24,"text":123,"correct":26},"建筑高度为27m的住宅建筑采用A级保温材料时可不设置防火隔离带",{"key":28,"text":125,"correct":26},"建筑高度为50m的普通单位办公楼采用B1级保温材料时，外墙上门、窗的耐火完整性不应低于0．50h且每层应设置防火隔离带",{"key":31,"text":127,"correct":22},"建筑高度为24m的普通单位办公楼采用B1级保温材料时，外墙上门、窗的耐火完整性不应低于0．50h且每层应设置防火隔离带",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":24,"analysis":33},932962,"建筑内部的配电箱不应直接安装在低于（ ）级的装修材料上。",[132,134,136,138],{"key":20,"text":133,"correct":26},"A级",{"key":24,"text":135,"correct":22},"B1级",{"key":28,"text":137,"correct":26},"B2级",{"key":31,"text":139,"correct":26},"B3级",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":20,"analysis":33},932963,"消防控制室的顶棚和墙面应采用（ ）装修材料。",[144,145,146,147],{"key":20,"text":133,"correct":22},{"key":24,"text":135,"correct":26},{"key":28,"text":137,"correct":26},{"key":31,"text":139,"correct":26},{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":24,"analysis":33},932964,"某商场，地上6层，建筑高度32m，第一至四层为商业营业厅，第五层为餐饮场所。第六层为电影院。建筑采用与基层墙体、装饰层之间有空腔的外墙外保温系统。下列关于该系统的做法中，错误的是（）。",[152,154,156,158],{"key":20,"text":153,"correct":26},"采用不燃材料在其外面设置完全覆盖的防护层",{"key":24,"text":155,"correct":22},"外墙外保温材料采用难燃材料",{"key":28,"text":157,"correct":26},"在每层楼板处，采用防火封堵材料封堵该系统与基层墙体、装饰层之间的空腔",{"key":31,"text":159,"correct":26},"屋面外保温材料采用难燃材料",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":28,"analysis":33},932965,"某独立建造的教学楼，地上5层，建筑高度为20m，每层6个教室，每个教室面积为90m2，教室之间采用不开设门、窗、洞口且耐火极限为3．0h的防火隔墙，该教室墙面可以采用燃烧性能等级不低于（ ）级的材料装修。",[164,165,166,167],{"key":20,"text":20,"correct":26},{"key":24,"text":76,"correct":26},{"key":28,"text":78,"correct":22},{"key":31,"text":80,"correct":26},{"id":169,"libraryId":5,"type":15,"typeLabel":16,"stem":170,"options":171,"answer":24,"analysis":33},932966,"建筑外墙采用保温材料与两侧墙体构成无空腔复合保温结构体时，当保温材料的燃烧性能为B1级时，保温材料两侧的墙体应采用不燃材料且厚度均不应小于（ ）mm。",[172,174,175,177],{"key":20,"text":173,"correct":26},"30",{"key":24,"text":92,"correct":22},{"key":28,"text":176,"correct":26},"80",{"key":31,"text":103,"correct":26},{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":28,"analysis":33},932967,"建筑的内、外保温系统，不宜采用（ ）级保温材料。",[182,183,184,185],{"key":20,"text":20,"correct":26},{"key":24,"text":76,"correct":26},{"key":28,"text":78,"correct":22},{"key":31,"text":80,"correct":26},{"id":187,"libraryId":5,"type":15,"typeLabel":16,"stem":188,"options":189,"answer":28,"analysis":33},932968,"下列建筑的屋面外保温系统的设置中，不符合规范要求的是（ ）",[190,192,194,196],{"key":20,"text":191,"correct":26},"屋面板的耐火极限为 0.50h 时，采用燃烧性能为 B1 级的保温材料",{"key":24,"text":193,"correct":26},"屋面板的耐火极限为 1.0h 时，采用燃烧性能为 B2 级的保温材料",{"key":28,"text":195,"correct":22},"屋面板的耐火极限为 0.75h 时，采用燃烧性能为 B2 级的保温材料",{"key":31,"text":197,"correct":26},"采用B2 级保温材料时，用不燃材料做防护层，防护层厚度为 10mm",{"id":199,"libraryId":5,"type":15,"typeLabel":16,"stem":200,"options":201,"answer":31,"analysis":33},932969,"下列关于装修材料分级的说法中，错误的是（ ）。",[202,204,206,208],{"key":20,"text":203,"correct":26},"安装在钢龙骨上，能达到 B1 级的纸面石膏板，可作为 A 级装修材料使用",{"key":24,"text":205,"correct":26},"单位面积质量小于 300g\u002F㎡的纸质、布质壁纸，当直接粘贴在 A 级基材上时，可作为 B1 级装修材料使用",{"key":28,"text":207,"correct":26},"施涂于 A 级基材上，湿涂覆比小于 1.5kg\u002F㎡，且涂层干膜厚度不大于 1.0mm的有机装修涂料，可作为B1级装修材料使用",{"key":31,"text":209,"correct":22},"施涂于 A 级基材上的有机装饰涂料，可做为 A 级装修材料使用",{"id":211,"libraryId":5,"type":212,"typeLabel":213,"stem":214,"options":215,"answer":227,"analysis":33},932971,2,"多选题","下列房间中，地面内部装修应采用A级装修材料的有（ ）。",[216,218,220,222,224],{"key":20,"text":217,"correct":26},"消防控制室",{"key":24,"text":219,"correct":22},"变压器室",{"key":28,"text":221,"correct":22},"机械加压送风机房",{"key":31,"text":223,"correct":22},"消防水泵房",{"key":225,"text":226,"correct":22},"E","通风和空调机房","BCDE",{"id":229,"libraryId":5,"type":212,"typeLabel":213,"stem":230,"options":231,"answer":242,"analysis":33},932972,"某建筑高度为34m的财贸金融楼，每层建筑面积为3000m2，设置火灾自动报警系统和自动灭火系统等，下列关于该建筑有窗办公室内部装修的做法中，正确的有（ ）。",[232,234,236,238,240],{"key":20,"text":233,"correct":26},"墙面采用墙布",{"key":24,"text":235,"correct":22},"地面铺装水泥木丝板",{"key":28,"text":237,"correct":22},"窗帘采用纯毛装饰布",{"key":31,"text":239,"correct":26},"顶棚采用矿棉板",{"key":225,"text":241,"correct":22},"隔断采用玻璃钢","BCE",{"id":244,"libraryId":5,"type":212,"typeLabel":213,"stem":245,"options":246,"answer":257,"analysis":33},932973,"建筑内部装修材料燃烧性能为 B1 的是（ ）。",[247,249,251,253,255],{"key":20,"text":248,"correct":26},"马赛克",{"key":24,"text":250,"correct":22},"多彩涂料",{"key":28,"text":252,"correct":22},"矿棉板",{"key":31,"text":254,"correct":22},"难燃聚氯乙烯塑料",{"key":225,"text":256,"correct":26},"半硬质 PVC 塑料地板","BCD",{"id":259,"libraryId":5,"type":212,"typeLabel":213,"stem":260,"options":261,"answer":227,"analysis":33},932974,"装修材料按实际应用分为（ ）。",[262,264,266,268,270],{"key":20,"text":263,"correct":26},"顶棚装修材料",{"key":24,"text":265,"correct":22},"装饰件",{"key":28,"text":267,"correct":22},"隔断",{"key":31,"text":269,"correct":22},"大型家具",{"key":225,"text":271,"correct":22},"装饰织物",{"id":273,"libraryId":5,"type":212,"typeLabel":213,"stem":274,"options":275,"answer":286,"analysis":33},932975,"下列关于特殊功能部位与用房装修防火要求说法正确的是（ ）。",[276,278,280,282,284],{"key":20,"text":277,"correct":22},"歌舞厅设置在一、二级耐火等级建筑的四层及四层以上时，室内装修的顶棚材料应采用A级装修材料",{"key":24,"text":279,"correct":22},"除地下建筑外，无窗房间内部装修材料的燃烧性能等级，除A级外，应在原规定基础上提高一级",{"key":28,"text":281,"correct":26},"图书馆、资料室的顶棚、墙面应采用A级装修材料，地面应使用不低于B2级的装修材料",{"key":31,"text":283,"correct":22},"设备机房内部所有装修均应采用A级装修材料",{"key":225,"text":285,"correct":22},"建筑内部装修不应遮挡消防设施、疏散指示标志及安全出口，并且不应妨碍消防设施和疏散走道的正常使用","ABDE",{"id":288,"libraryId":5,"type":212,"typeLabel":213,"stem":289,"options":290,"answer":301,"analysis":33},932976,"某8层住宅建筑，层高3m，首层地面标高±0．000m，室外地坪标高-0．600m，平屋面面层标高24．200mm。对该建筑外墙进行保温设计，下列选用的保温材料和方式中，符合规范的有（）。",[291,293,295,297,299],{"key":20,"text":292,"correct":26},"除楼梯间外，内保温材料采用燃烧性能为B1级的聚氨酯泡沫板",{"key":24,"text":294,"correct":22},"外保温体系与基层墙体无空腔，保温材料采用矿棉板",{"key":28,"text":296,"correct":26},"除楼梯间外，内保温材料采用燃烧性能为B2级的聚乙烯泡沫板",{"key":31,"text":298,"correct":22},"外保温体系与基层墙体无空腔，保温材料采用燃烧性能为B1级的聚氨酯泡沫板",{"key":225,"text":300,"correct":22},"外保温体系与基层墙体无空腔，保温材料采用燃烧性能为B1级的聚苯乙烯泡沫板","BDE",{"id":303,"libraryId":5,"type":212,"typeLabel":213,"stem":304,"options":305,"answer":227,"analysis":33},932977,"某住宅建筑，二级耐火等级，首层地面标高为±0．000m，室外地坪标高为-0．600m，平屋面面层标高为24．600m。对该住宅外墙保温系统进行防火设计时，选用的保温材料和方式中，符合规范要求的有（ ）。",[306,308,310,312,314],{"key":20,"text":307,"correct":26},"外保温体系与基层墙体有空腔，保温材料采用燃烧性能为B1级的聚氨酯泡沫板",{"key":24,"text":309,"correct":22},"外保温体系与基层墙体有空腔，保温材料采用泡沫玻璃",{"key":28,"text":311,"correct":22},"内保温材料采用岩棉",{"key":31,"text":313,"correct":22},"外保温体系与基层墙体无空腔，保温材料采用燃烧性能为B1级的聚氨酯泡沫板，每层设置防火隔离带",{"key":225,"text":315,"correct":22},"外保温体系与基层墙体无空腔，保温材料采用燃烧性能为B2级的聚苯乙烯泡沫板，每层设置防火隔离带，墙上门、窗的耐火完整性不低于0.5h",{"id":317,"libraryId":5,"type":15,"typeLabel":16,"stem":318,"options":319,"answer":20,"analysis":33},932978,"某酒吧在进行内部装修时，采用到顶的储酒壁柜分隔多个区域。根据《建筑内部装修设计防火规范》（GB 50222—2017）的规定和实际应用分类，该壁柜可划分为（ ）。",[320,321,323,324],{"key":20,"text":269,"correct":22},{"key":24,"text":322,"correct":26},"固定家具",{"key":28,"text":267,"correct":26},{"key":31,"text":325,"correct":26},"隔断装修材料",{"id":327,"libraryId":5,"type":15,"typeLabel":16,"stem":328,"options":329,"answer":24,"analysis":33},932979,"下列装修材料中，燃烧性能不属于B1级的是（ ）。",[330,332,334,335],{"key":20,"text":331,"correct":26},"纸面石膏板",{"key":24,"text":333,"correct":22},"木质人造板",{"key":28,"text":250,"correct":26},{"key":31,"text":336,"correct":26},"珍珠岩板",{"id":338,"libraryId":5,"type":15,"typeLabel":16,"stem":339,"options":340,"answer":24,"analysis":33},932980,"下列关于消防控制室建筑内部装修防火的说法，不正确的是（ ）。",[341,343,345,347],{"key":20,"text":342,"correct":26},"消防控制室的地面可以采用B1级装修材料",{"key":24,"text":344,"correct":22},"消防控制室的墙面可以采用B1级装修材料",{"key":28,"text":346,"correct":26},"消防控制室的顶棚必须采用A级装修材料",{"key":31,"text":348,"correct":26},"消防控制室的顶棚和墙面均应采用A级装修材料",{"id":350,"libraryId":5,"type":15,"typeLabel":16,"stem":351,"options":352,"answer":24,"analysis":33},932981,"某独立建造的地下餐饮场所的地上休息室，其地面应采用燃烧性能不低于（ ）级的材料装修。",[353,354,355,356],{"key":20,"text":20,"correct":26},{"key":24,"text":76,"correct":22},{"key":28,"text":78,"correct":26},{"key":31,"text":80,"correct":26},{"id":358,"libraryId":5,"type":15,"typeLabel":16,"stem":359,"options":360,"answer":28,"analysis":33},932982,"下列关于建筑外保温材料的说法，不正确的是（ ）。",[361,363,365,367],{"key":20,"text":362,"correct":26},"岩棉在建筑外保温材料中代表无机保温材料，通常被认定为不燃材料",{"key":24,"text":364,"correct":26},"聚氨酯是在建筑外保温材料中代表有机保温材料，通常被认定为可燃材料",{"key":28,"text":366,"correct":22},"EPS板在建筑外保温材料中代表有机一无机复合型保温材料，通常被认定为难燃材料",{"key":31,"text":368,"correct":26},"泡沫玻璃在建筑外保温材料中的燃烧性能等级为A级",{"id":370,"libraryId":5,"type":15,"typeLabel":16,"stem":371,"options":372,"answer":20,"analysis":33},932983,"某高层办公楼，当建筑的屋面与外墙外保温系统均采用胶粉聚苯颗粒保温浆料作为保温材料时，屋面与外墙之间应采用宽度不小于（ ）m的不燃材料设置防火隔离带进行分隔。",[373,375,377,379],{"key":20,"text":374,"correct":22},"0．5",{"key":24,"text":376,"correct":26},"1",{"key":28,"text":378,"correct":26},"1．5",{"key":31,"text":380,"correct":26},"0．1",{"id":382,"libraryId":5,"type":15,"typeLabel":16,"stem":383,"options":384,"answer":24,"analysis":33},932984,"下列装修材料的燃烧性能为B1级的是（ ）。",[385,387,388,390],{"key":20,"text":386,"correct":26},"石膏板",{"key":24,"text":331,"correct":22},{"key":28,"text":389,"correct":26},"PVC卷材地板",{"key":31,"text":391,"correct":26},"塑料贴面装饰板",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":28,"analysis":33},932985,"下列关于建筑外保温材料选择的说法，不正确的是（）。",[396,398,400,402],{"key":20,"text":397,"correct":26},"当采用建筑外墙与基层墙体、装饰层之间无空腔的外墙外保温系统时，建筑高度为33m的住宅采用胶粉聚苯颗粒浆料作为外保温材料",{"key":24,"text":399,"correct":26},"当采用建筑外墙与基层墙体、装饰层之间无空腔的外墙外保温系统时，建筑高度为95m的住宅采用岩棉板作为外保温材料",{"key":28,"text":401,"correct":22},"当采用建筑外墙与基层墙体、装饰层之间无空腔的外墙外保温系统时，建筑高度50m的办公楼采用EPS板作为外保温材料",{"key":31,"text":403,"correct":26},"当采用建筑外墙与基层墙体、装饰层之间有空腔的外墙外保温系统时，建筑高度24m的办公楼采用岩棉板作为外保温材料",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":31,"analysis":33},932986,"某建筑高度为27m的办公建筑，耐火等级为二级，屋面板的耐火极限为1．00h，采用与基层墙体、装饰层之间无空腔的建筑外墙外保温和屋面外保温系统，下列说法中不正确的是（）。",[408,410,412,414],{"key":20,"text":409,"correct":26},"当屋面与外墙均采用B1级保温材料时，屋面与外墙之间应采用宽度不小于500mm的不燃材料做防火隔离带",{"key":24,"text":411,"correct":26},"屋面板可以采用B2级保温材料",{"key":28,"text":413,"correct":26},"当外墙采用B1级保温材料时，建筑外墙上门、窗的耐火完整性不应低于0．50h",{"key":31,"text":415,"correct":22},"外墙和屋面保温系统均采用B1级保温材料时，其防护层的厚度均不应小于10mm",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":24,"analysis":33},932987,"单位面积质量小于（ ）g／m2的纸质、布质壁纸，当直接粘贴在A级基材上时，可作为B1级装修材料使用。",[420,422,424,426],{"key":20,"text":421,"correct":26},"150",{"key":24,"text":423,"correct":22},"300",{"key":28,"text":425,"correct":26},"400",{"key":31,"text":427,"correct":26},"500",{"id":429,"libraryId":5,"type":15,"typeLabel":16,"stem":430,"options":431,"answer":24,"analysis":33},932988,"座位数3000的体育馆地面最低应采用（ ）装修材料。",[432,433,434,435],{"key":20,"text":133,"correct":26},{"key":24,"text":135,"correct":22},{"key":28,"text":137,"correct":26},{"key":31,"text":139,"correct":26},{"id":437,"libraryId":5,"type":212,"typeLabel":213,"stem":438,"options":439,"answer":450,"analysis":33},932989,"下列关于单、多层民用建筑内部装修的做法，正确的有（ ）。",[440,442,444,446,448],{"key":20,"text":441,"correct":22},"某酒店内的封闭楼梯间，全部采用A级装修材料",{"key":24,"text":443,"correct":22},"某总建筑面积为2900m2的通讯营业厅，其地面和墙面均采用B1级装修材料",{"key":28,"text":445,"correct":22},"某大型室内体育馆的座位数量为3100个，当馆内同时装有自动喷水灭火系统和火灾自动报警系统时，其顶棚采用B1级装修材料",{"key":31,"text":447,"correct":26},"某办公楼设置自动喷水灭火系统和火灾自动报警系统的地上水平疏散走道，顶棚采用B1级装修材料",{"key":225,"text":449,"correct":26},"某商场的通风和空调机房，墙面采用B1级装修材料","ABC",{"id":452,"libraryId":5,"type":212,"typeLabel":213,"stem":453,"options":454,"answer":465,"analysis":33},932990,"某图书馆建筑，建筑高度为18m，屋面板的耐火极限为1．5h，对图书馆的外墙进行保温设计，下列不符合规范要求的是（ ）。",[455,457,459,461,463],{"key":20,"text":456,"correct":22},"采用外墙内保温时，建筑内疏散楼梯使用燃烧性能为B1级的保温材料",{"key":24,"text":458,"correct":26},"保温材料的防护层使用不燃烧材料",{"key":28,"text":460,"correct":22},"采用外墙外保温时，使用燃烧性能为B1级的保温材料",{"key":31,"text":462,"correct":26},"对建筑的外墙装饰层，采用燃烧性能为B1级的材料",{"key":225,"text":464,"correct":26},"建筑屋面的外保温系统，使用燃烧性能为B2级的保温材料","AC",{"id":467,"libraryId":5,"type":212,"typeLabel":213,"stem":468,"options":469,"answer":227,"analysis":33},932991,"下列关于建筑外墙保温系统的说法中，正确的是（）。",[470,472,474,476,478],{"key":20,"text":471,"correct":26},"建筑高度为50m的办公建筑，采用与基层墙体、装饰层之间有空腔的外墙外保温系统，当采用燃烧性能为B1级的保温材料时，外墙上门、窗的耐火完整性不应低于0．50h且每层应设置防火隔离带",{"key":24,"text":473,"correct":22},"某建筑高度为54m的办公楼内的办公室，外墙内保温系统应采用低烟、低毒且燃烧性能不低于B1级的保温材料",{"key":28,"text":475,"correct":22},"某建筑高度为12m的独立建造的老年人日间照料设施，采用与基层墙体、装饰层之间无空腔的外墙外保温系统，外墙外保温系统应采用燃烧性能为A级的保温材料",{"key":31,"text":477,"correct":22},"某建筑高度为12m的歌舞厅建筑，采用与基层墙体、装饰层之间无空腔的形式，外墙外保温系统应采用燃烧性能为A级的保温材料",{"key":225,"text":479,"correct":22},"某建筑高度为18m的独立建造的办公楼，采用与基层墙体、装饰层之间无空腔的外墙外保温系统，当采用燃烧性能为B1级的保温材料时，层间应设置防火隔离带",{"id":481,"libraryId":5,"type":212,"typeLabel":213,"stem":482,"options":483,"answer":494,"analysis":33},932992,"下列关于地上建筑内部装修材料防火要求的叙述，正确的是（）。",[484,486,488,490,492],{"key":20,"text":485,"correct":22},"疏散走道和安全出口门厅的顶棚应采用A级装修材料，其他装修应采用不低于B1级的装修材料。",{"key":24,"text":487,"correct":22},"建筑内划分防烟分区所使用的挡烟垂壁应采用A级装修材料",{"key":28,"text":489,"correct":26},"消防控制室的顶棚和墙面应使用不低于B1级的装修材料，地面及其他装修应采用A级装修材料",{"key":31,"text":491,"correct":22},"建筑内部的配电箱不应直接安装在低于B1级的装修材料上",{"key":225,"text":493,"correct":26},"无自然采光楼梯间、封闭楼梯间、防烟楼梯间的顶棚、墙面和地面应采用不低于B1级的装修材料","ABD",{"id":496,"libraryId":5,"type":15,"typeLabel":16,"stem":497,"options":498,"answer":20,"analysis":33},932993,"供消防车取水的天然水源和消防水池应设置消防车道，消防车道的边缘距离取水点不宜大于（ ）m。",[499,501,503,505],{"key":20,"text":500,"correct":22},"2",{"key":24,"text":502,"correct":26},"3",{"key":28,"text":504,"correct":26},"4",{"key":31,"text":86,"correct":26},{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":31,"analysis":33},932994,"某建筑高度为42m的玩具厂，地上10层，耐火等级为一级，每层建筑面积为6000m2，设有消防电梯，且消防电梯与疏散楼梯间合用前室。下列做法中正确的是（ ）。",[510,512,514,516],{"key":20,"text":511,"correct":26},"在前室入口处设置耐火极限为3．00h的卷帘门",{"key":24,"text":513,"correct":26},"前室的建筑面积为10m2",{"key":28,"text":515,"correct":26},"消防电梯内部装修材料为纸面石膏板",{"key":31,"text":517,"correct":22},"设置1台消防电梯",{"id":519,"libraryId":5,"type":15,"typeLabel":16,"stem":520,"options":521,"answer":24,"analysis":33},932995,"下列有关建筑直升机停机坪设置的说法中，错误的是（ ）。",[522,524,526,528],{"key":20,"text":523,"correct":26},"建筑高度大于100m且标准层建筑面积大于2000m2的公共建筑，其屋顶宜设置直升机停机坪",{"key":24,"text":525,"correct":22},"建筑通向停机坪的出口的宽度不宜小于1.00m",{"key":28,"text":527,"correct":26},"在停机坪的适当位置应设置消火栓",{"key":31,"text":529,"correct":26},"在停机坪的四周应设置航空障碍灯，并应设置应急照明",{"id":531,"libraryId":5,"type":15,"typeLabel":16,"stem":532,"options":533,"answer":28,"analysis":33},932996,"下列消防车道设置正确的是（ ）。",[534,536,538,540],{"key":20,"text":535,"correct":26},"超过1500个座位的电影院、会堂和3000个座位的体育馆必须设置环形消防车道",{"key":24,"text":537,"correct":26},"消防水源地的消防车道，消防车道边缘距离取水点应为 2～6m",{"key":28,"text":539,"correct":22},"某 L 型建筑，两个边的长度均为 120m，则该建筑应设置穿过建筑物消防车道",{"key":31,"text":541,"correct":26},"某建筑高度为 30m 的 10 层政府大楼，其消防救援场地为10m×10m",{"id":543,"libraryId":5,"type":15,"typeLabel":16,"stem":544,"options":545,"answer":28,"analysis":33},932997,"有封闭内院或天井的建筑物沿街时，应设置连通街道和内院的人行通道（可利用楼梯间），其间距不宜大于（ ）。",[546,548,550,552],{"key":20,"text":547,"correct":26},"60m",{"key":24,"text":549,"correct":26},"70m",{"key":28,"text":551,"correct":22},"80m",{"key":31,"text":553,"correct":26},"90m",{"id":555,"libraryId":5,"type":15,"typeLabel":16,"stem":556,"options":557,"answer":28,"analysis":33},932998,"消防车的最小转弯半径是指消防车回转时消防车的前轮外侧循圆曲线行走轨迹的半径，其中普通消防车转弯半径至少为（ ）m。",[558,560,562,564],{"key":20,"text":559,"correct":26},"6",{"key":24,"text":561,"correct":26},"7",{"key":28,"text":563,"correct":22},"9",{"key":31,"text":565,"correct":26},"12",{"id":567,"libraryId":5,"type":15,"typeLabel":16,"stem":568,"options":569,"answer":24,"analysis":33},932999,"登高场地距建筑外墙不宜小于（ ），且不应大于（ ）。",[570,572,574,576],{"key":20,"text":571,"correct":26},"5m，8m",{"key":24,"text":573,"correct":22},"5m，10m",{"key":28,"text":575,"correct":26},"7m，10m",{"key":31,"text":577,"correct":26},"7m，12m",{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":580,"options":581,"answer":24,"analysis":33},933000,"某“口”形建筑，建筑高度为40m，临街长边为160m，短边为80m，内部设有内院，设置连通街道和内院的人行通道时间距不宜大于（ ）m。",[582,583,584,585],{"key":20,"text":92,"correct":26},{"key":24,"text":176,"correct":22},{"key":28,"text":421,"correct":26},{"key":31,"text":586,"correct":26},"220",{"id":588,"libraryId":5,"type":15,"typeLabel":16,"stem":589,"options":590,"answer":20,"analysis":33},933001,"某新建建筑高度为29m的住宅楼，布置消防车登高操作场地时，其最小平面尺寸为（ ）。",[591,593,595,597],{"key":20,"text":592,"correct":22},"15m×10m",{"key":24,"text":594,"correct":26},"20m×16m",{"key":28,"text":596,"correct":26},"10m×16m",{"key":31,"text":598,"correct":26},"20m×10m",{"id":600,"libraryId":5,"type":15,"typeLabel":16,"stem":601,"options":602,"answer":28,"analysis":33},933002,"下列建筑中，无须设置消防电梯的是（ ）。",[603,605,607,609],{"key":20,"text":604,"correct":26},"建筑高度为35m的住宅建筑",{"key":24,"text":606,"correct":26},"建筑高度为33m的二类高层公共建筑",{"key":28,"text":608,"correct":22},"局部建筑高度为30m，且局部高出部分的每层建筑面积为30m2的丁、戊类厂房",{"key":31,"text":610,"correct":26},"埋深12m，总建筑面积为3200m2的半地下室",{"id":612,"libraryId":5,"type":15,"typeLabel":16,"stem":613,"options":614,"answer":28,"analysis":33},933003,"下列关于灭火救援窗的现场检查，不符合规范要求的是（ ）。",[615,617,619,621],{"key":20,"text":616,"correct":26},"灭火救援窗的净高度和净宽度均为1．2m",{"key":24,"text":618,"correct":26},"灭火救援窗下沿距室内地面1．0m",{"key":28,"text":620,"correct":22},"灭火救援窗的间距为30m",{"key":31,"text":622,"correct":26},"每个防火分区在消防登高操作面设置3个灭火救援窗",[624,627,630,633,636,639],{"id":15,"name":625,"category":7,"favorite":626},"领导干部任职前廉政法规知识测试题",92,{"id":628,"name":629,"category":7,"favorite":15},595,"建筑结构与设备",{"id":631,"name":632,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":634,"name":635,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":637,"name":638,"category":7,"favorite":8},534,"BIM工程师",{"id":640,"name":638,"category":7,"favorite":8},535]