[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-25":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":622},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,25,50,2960,[13,34,46,58,70,82,100,115,127,139,151,163,175,187,199,211,223,235,247,259,271,283,295,305,317,325,335,350,365,377,388,398,410,422,434,446,458,470,482,494,502,517,532,547,559,570,582,594,606,614],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":27,"analysis":33},932901,1,"单选题","下列不属于爆炸性物质分类的是（ ）。",[19,23,26,30],{"key":20,"text":21,"correct":22},"A","矿井甲烷",false,{"key":24,"text":25,"correct":22},"B","爆炸性气体混合物",{"key":27,"text":28,"correct":29},"C","爆炸性液体",true,{"key":31,"text":32,"correct":22},"D","爆炸性粉尘","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":31,"analysis":33},932902,"正常运行条件下，不能够点燃周围的爆炸性气体环境，也不大可能发生引起点燃的故障，该类型设备仅适用于2区危险环境的电器设备指的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"增安型",{"key":24,"text":41,"correct":22},"本质安全型",{"key":27,"text":43,"correct":22},"特殊型",{"key":31,"text":45,"correct":29},"无火花型",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},932904,"厂房内设置甲、乙类中间仓库时，其储量不宜超过（ ）的需要量。",[50,52,54,56],{"key":20,"text":51,"correct":22},"一天",{"key":24,"text":53,"correct":22},"两天",{"key":27,"text":55,"correct":22},"一夜",{"key":31,"text":57,"correct":29},"一昼夜",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":27,"analysis":33},932905,"下列可划为1区的情况是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"油、水分离器等直接与空间接触的易燃液体的表面",{"key":24,"text":65,"correct":22},"正常运行时不能出现释放可燃物质的泵、压缩机和阀门的密封处",{"key":27,"text":67,"correct":29},"储存有可燃液体的容器上的排水口处，在正常运行中，当水排掉时，该处可能会向空间释放可燃物质",{"key":31,"text":69,"correct":22},"正常运行时不能向空间释放可燃物质的安全阀、排气孔和其他孔口",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":27,"analysis":33},932906,"为防止液体流散，在桶装仓库门洞处修筑漫坡，该漫坡高度为（ ）mm。",[74,76,78,80],{"key":20,"text":75,"correct":22},"50～150",{"key":24,"text":77,"correct":22},"100～300",{"key":27,"text":79,"correct":29},"150～300",{"key":31,"text":81,"correct":22},"300～450",{"id":83,"libraryId":5,"type":84,"typeLabel":85,"stem":86,"options":87,"answer":99,"analysis":33},932907,2,"多选题","下列防爆电气设备适用于1区危险环境的有（ ）。",[88,90,92,94,96],{"key":20,"text":89,"correct":29},"隔爆型（d）",{"key":24,"text":91,"correct":22},"粉尘防爆型",{"key":27,"text":93,"correct":29},"本质安全型（ib）",{"key":31,"text":95,"correct":22},"本质安全型（i",{"key":97,"text":98,"correct":29},"E","油浸型（o）","ACE",{"id":101,"libraryId":5,"type":84,"typeLabel":85,"stem":102,"options":103,"answer":114,"analysis":33},932908,"建筑防爆的预防性技术措施包括消除或控制能引起爆炸的各种火源，主要是指（ ）。",[104,106,108,110,112],{"key":20,"text":105,"correct":29},"防止撞击、摩擦产生火花",{"key":24,"text":107,"correct":29},"防止高温表面成为点火源",{"key":27,"text":109,"correct":29},"防止日光照射",{"key":31,"text":111,"correct":29},"防止电气火灾及明火",{"key":97,"text":113,"correct":22},"加强通风除尘","ABCD",{"id":116,"libraryId":5,"type":15,"typeLabel":16,"stem":117,"options":118,"answer":31,"analysis":33},932909,"下列关于干式除尘器设置的说法，不正确的是（ ）。",[119,121,123,125],{"key":20,"text":120,"correct":22},"净化有爆炸危险粉尘的干式除尘器和过滤器宜布置在厂房外的独立建筑内，建筑外墙与所属厂房的防火间距不应小于10m",{"key":24,"text":122,"correct":22},"具备连续清灰功能干式除尘器的设备房布置在厂房内时，采用耐火极限3．00h的防火隔墙和1．50h的楼板与其他部位分隔",{"key":27,"text":124,"correct":22},"净化有爆炸危险粉尘和碎屑的除尘器均应设置泄压装置",{"key":31,"text":126,"correct":29},"净化有爆炸危险粉尘的干式除尘器应布置在系统的正压段上",{"id":128,"libraryId":5,"type":15,"typeLabel":16,"stem":129,"options":130,"answer":31,"analysis":33},932910,"下列厂房中，可以采用湿式除尘器的是（ ）。",[131,133,135,137],{"key":20,"text":132,"correct":22},"碳化钙厂房",{"key":24,"text":134,"correct":22},"锌粉加工车间",{"key":27,"text":136,"correct":22},"铝镁合金加工车间",{"key":31,"text":138,"correct":29},"煤粉厂房",{"id":140,"libraryId":5,"type":15,"typeLabel":16,"stem":141,"options":142,"answer":27,"analysis":33},932911,"排除、输送温度超过80℃的空气或其他气体以及容易起火的碎屑的管道，与可燃或难燃物体之间应采取一定措施。下列做法中符合规定的是（ ）。",[143,145,147,149],{"key":20,"text":144,"correct":22},"与难燃物体之间应保持不小于100mm的间隙",{"key":24,"text":146,"correct":22},"采用厚度为10mm的不燃材料隔热",{"key":27,"text":148,"correct":29},"与可燃物体之间保持不小于160mm的间隙",{"key":31,"text":150,"correct":22},"采用厚度为20mm的不燃材料隔热",{"id":152,"libraryId":5,"type":15,"typeLabel":16,"stem":153,"options":154,"answer":20,"analysis":33},932912,"电加热设备与送风设备的电气开关应有（ ），以防风机停转时，电加热设备仍单独继续加热，温度过高而引起火灾。",[155,157,159,161],{"key":20,"text":156,"correct":29},"联锁装置",{"key":24,"text":158,"correct":22},"防爆装置",{"key":27,"text":160,"correct":22},"隔热装置",{"key":31,"text":162,"correct":22},"隔温装置",{"id":164,"libraryId":5,"type":15,"typeLabel":16,"stem":165,"options":166,"answer":24,"analysis":33},932913,"关于采暖设备的防火防爆措施，说法错误的是（ ）。",[167,169,171,173],{"key":20,"text":168,"correct":22},"采暖管道与建筑物的可燃构件保持一定的距离",{"key":24,"text":170,"correct":29},"车库内采用火炉采暖方式",{"key":27,"text":172,"correct":22},"电加热设备与送风设备的电气开关装有联锁装置",{"key":31,"text":174,"correct":22},"存在与采暖管道接触能引起燃烧爆炸的气体的房间内必须敷设采暖管道时，应采用不燃材料隔热",{"id":176,"libraryId":5,"type":15,"typeLabel":16,"stem":177,"options":178,"answer":31,"analysis":33},932914,"燃油或燃气锅炉房采用机械通风设施时，该机械通风设备应设置导除静电的接地装置。下列关于通风量的确定，不符合规定的是（ ）。",[179,181,183,185],{"key":20,"text":180,"correct":22},"燃油锅炉房的正常通风量按换气次数4次／h确定",{"key":24,"text":182,"correct":22},"燃油锅炉房的事故排风量按换气次数7次／h确定",{"key":27,"text":184,"correct":22},"燃气锅炉房的正常通风量按换气次数7次／h确定",{"key":31,"text":186,"correct":29},"燃气锅炉房的事故排风量按换气次数9次／h确定",{"id":188,"libraryId":5,"type":15,"typeLabel":16,"stem":189,"options":190,"answer":24,"analysis":33},932915,"一座建筑在建设时，外部除了要考虑城市规划和在城市中的设置位置，以及内部除了考虑满足功能需求的划分外，还应对建筑物内部空间进行合理布置。下列建筑内部的布置不符合规范要求的是（ ）。",[191,193,195,197],{"key":20,"text":192,"correct":22},"常压燃气锅炉房设置在建筑的地下二层靠外墙部位",{"key":24,"text":194,"correct":29},"锅炉房与其他部位之间采用耐火极限不低于2．50h的防火隔墙和1．00h的不燃性楼板隔开",{"key":27,"text":196,"correct":22},"变压器室与配电室之间，采用耐火极限2．00h的防火隔墙隔开",{"key":31,"text":198,"correct":22},"锅炉房内设置储油间时，其总储存量为0．5m3",{"id":200,"libraryId":5,"type":15,"typeLabel":16,"stem":201,"options":202,"answer":27,"analysis":33},932916,"下列关于电力变压器的防火防爆措施检查，不符合规范要求的是（ ）。",[203,205,207,209],{"key":20,"text":204,"correct":22},"油浸变压器室、高压配电装置室的耐火等级为二级",{"key":24,"text":206,"correct":22},"10kV及以下的预装式变电站与民用建筑的防火间距为5．00m",{"key":27,"text":208,"correct":29},"油浸电力变压器布置在民用建筑内时，变压器室与其他部位之间应采用耐火极限不低于2．00h的不燃性隔墙和1．00h的不燃性楼板隔开",{"key":31,"text":210,"correct":22},"油浸电力变压器布置在民用建筑内时，变压器室与配电室之间，应采用耐火极限不低于2．00h的防火隔墙隔开",{"id":212,"libraryId":5,"type":15,"typeLabel":16,"stem":213,"options":214,"answer":24,"analysis":33},932917,"限制变压器接地电阻是电力变压器本体防火防爆措施之一，容量在100kVA以下的变压器接地电阻应不大于（ ）Ω。",[215,217,219,221],{"key":20,"text":216,"correct":22},"5",{"key":24,"text":218,"correct":29},"10",{"key":27,"text":220,"correct":22},"15",{"key":31,"text":222,"correct":22},"20",{"id":224,"libraryId":5,"type":15,"typeLabel":16,"stem":225,"options":226,"answer":27,"analysis":33},932918,"下列关于布置在建筑内的柴油发电机房的防火设计做法，不正确的是（）。",[227,229,231,233],{"key":20,"text":228,"correct":22},"柴油发电机房内设有储油间，其总储存量为0．5m3",{"key":24,"text":230,"correct":22},"柴油发电机房的储油间采用耐火极限为3．00h的防火隔墙与发电机间分隔，隔墙上开甲级防火门",{"key":27,"text":232,"correct":29},"柴油发电机房设置有火灾报警装置，并采用耐火极限为2．50h的防火隔墙和1．50h的不燃性楼板与其他部位分隔，连通处采用乙级防火门",{"key":31,"text":234,"correct":22},"柴油发电机房储油间的油箱密闭且设置有通向室外的通气管，通气管设置有带阻火器的呼吸阀",{"id":236,"libraryId":5,"type":15,"typeLabel":16,"stem":237,"options":238,"answer":24,"analysis":33},932919,"某煤粉加工厂设有净化厂房空气中煤粉的干式除尘器和过滤器等设备，下列说法中错误的是（ ）。",[239,241,243,245],{"key":20,"text":240,"correct":22},"干式除尘器和过滤器宜布置在厂房外的独立建筑内，且与所属厂房的防火间距不应小于10m",{"key":24,"text":242,"correct":29},"干式除尘器和过滤器布置在厂房内的单独房间内时，应采用耐火极限不低于2．00h的防火隔墙和1．50h的楼板与其他部位分隔",{"key":27,"text":244,"correct":22},"干式除尘器、过滤器和管道上均应设置泄压设施",{"key":31,"text":246,"correct":22},"干式除尘器和过滤器应布置在系统的负压段上",{"id":248,"libraryId":5,"type":15,"typeLabel":16,"stem":249,"options":250,"answer":20,"analysis":33},932920,"下列关于直燃机房的防火防爆措施的说法，错误的是（ ）。",[251,253,255,257],{"key":20,"text":252,"correct":29},"主机房应设置可靠的送风、排风系统，室内不应出现正压",{"key":24,"text":254,"correct":22},"应设置双回路供电，并应在末端配电箱处设置自动切换装置",{"key":27,"text":256,"correct":22},"从机房最远点到安全出口的距离不应超过 35m",{"key":31,"text":258,"correct":22},"机房内的电气设备应采用防爆型",{"id":260,"libraryId":5,"type":15,"typeLabel":16,"stem":261,"options":262,"answer":20,"analysis":33},932921,"某丙类厂房的通风管道，输送 83℃的空气，该管道与可燃物之间应保持（ ）的间隙或采用厚度（ ）的不燃材料隔热。",[263,265,267,269],{"key":20,"text":264,"correct":29},"不小于 150mm，不小于 50mm",{"key":24,"text":266,"correct":22},"不小于 100mm，不小于 50mm",{"key":27,"text":268,"correct":22},"不小于 100mm，不小于 100mm",{"key":31,"text":270,"correct":22},"不小于 150mm，不小于 150mm",{"id":272,"libraryId":5,"type":15,"typeLabel":16,"stem":273,"options":274,"answer":27,"analysis":33},932922,"某铝粉生产厂房内可以采用（ ）采暖。",[275,277,279,281],{"key":20,"text":276,"correct":22},"明火",{"key":24,"text":278,"correct":22},"表面平均温度不超过 82.5℃的电散热器",{"key":27,"text":280,"correct":29},"不循环使用的热风",{"key":31,"text":282,"correct":22},"电散热器",{"id":284,"libraryId":5,"type":15,"typeLabel":16,"stem":285,"options":286,"answer":27,"analysis":33},932923,"当采暖管道温度大于100℃时，管道与可燃构件之间的距离不小于（ ）mm。",[287,289,291,293],{"key":20,"text":288,"correct":22},"50",{"key":24,"text":290,"correct":22},"70",{"key":27,"text":292,"correct":29},"100",{"key":31,"text":294,"correct":22},"150",{"id":296,"libraryId":5,"type":15,"typeLabel":16,"stem":297,"options":298,"answer":20,"analysis":33},932924,"通风、空气调节系统的风管在穿越通风、空气调节机房的房间隔墙和楼板处应设置公称动作温度为（ ）℃的防火阀。",[299,300,302,303],{"key":20,"text":290,"correct":29},{"key":24,"text":301,"correct":22},"80",{"key":27,"text":292,"correct":22},{"key":31,"text":304,"correct":22},"120",{"id":306,"libraryId":5,"type":15,"typeLabel":16,"stem":307,"options":308,"answer":27,"analysis":33},932925,"为防止纤维或粉尘积聚在管道和散热器上受热自燃，散热器表面平均温度不应超过（ ）。",[309,311,313,315],{"key":20,"text":310,"correct":22},"90℃",{"key":24,"text":312,"correct":22},"70℃",{"key":27,"text":314,"correct":29},"82．5℃",{"key":31,"text":316,"correct":22},"80℃",{"id":318,"libraryId":5,"type":15,"typeLabel":16,"stem":319,"options":320,"answer":31,"analysis":33},932926,"排除和输送温度超过80℃的空气或其他气体以及易燃碎屑的管道，与可燃或难燃物体之间的间隙不应小于（ ）mm。",[321,322,323,324],{"key":20,"text":288,"correct":22},{"key":24,"text":301,"correct":22},{"key":27,"text":292,"correct":22},{"key":31,"text":294,"correct":29},{"id":326,"libraryId":5,"type":15,"typeLabel":16,"stem":327,"options":328,"answer":20,"analysis":33},932927,"车库的通风、空调系统风管穿墙处设置的防火阀的动作温度宜为（ ）。",[329,330,331,333],{"key":20,"text":312,"correct":29},{"key":24,"text":310,"correct":22},{"key":27,"text":332,"correct":22},"150℃",{"key":31,"text":334,"correct":22},"280℃",{"id":336,"libraryId":5,"type":84,"typeLabel":85,"stem":337,"options":338,"answer":349,"analysis":33},932928,"下列关于电力变压器的说法，不正确的是（ ）。",[339,341,343,345,347],{"key":20,"text":340,"correct":22},"油浸电力变压器下面应设置储存变压器全部油量的事故储油设施",{"key":24,"text":342,"correct":22},"变、配电所不应设置在甲、乙类厂房内或贴邻建造",{"key":27,"text":344,"correct":29},"10kV及以下的预装式变电站与民用建筑贴邻时应采用耐火极限不低于3．00h的防火墙分隔",{"key":31,"text":346,"correct":22},"独立建造的浸变压器室、高压配电装置室的耐火等级不应低于二级",{"key":97,"text":348,"correct":29},"变压器室设置在建筑内时应设置在首层或地下一层或地下二层靠外墙部位","CE",{"id":351,"libraryId":5,"type":84,"typeLabel":85,"stem":352,"options":353,"answer":364,"analysis":33},932929,"直燃机组应布置在（ ）。",[354,356,358,360,362],{"key":20,"text":355,"correct":29},"首层",{"key":24,"text":357,"correct":29},"地下一层靠外墙部位",{"key":27,"text":359,"correct":22},"人员密集场所的上一层",{"key":31,"text":361,"correct":22},"人员密集场所的下一层",{"key":97,"text":363,"correct":22},"贴邻人员密集场所","AB",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":31,"analysis":33},932930,"下列工业建筑中，可以使用明火和电热散热器采暖的是（ ）。",[369,371,373,375],{"key":20,"text":370,"correct":22},"白兰地蒸馏车间",{"key":24,"text":372,"correct":22},"成品油纸库房",{"key":27,"text":374,"correct":22},"氨压缩机房",{"key":31,"text":376,"correct":29},"白兰地成品库",{"id":378,"libraryId":5,"type":15,"typeLabel":16,"stem":379,"options":380,"answer":31,"analysis":33},932931,"输煤廊的散热器表面平均温度不应超过（ ）℃。",[381,382,384,386],{"key":20,"text":290,"correct":22},{"key":24,"text":383,"correct":22},"82．5",{"key":27,"text":385,"correct":22},"90",{"key":31,"text":387,"correct":29},"130",{"id":389,"libraryId":5,"type":15,"typeLabel":16,"stem":390,"options":391,"answer":27,"analysis":33},932932,"供暖管道与可燃物之间应保持一定距离，当供暖管道的表面温度为100℃时，其间距不应小于（ ）mm。",[392,394,396,397],{"key":20,"text":393,"correct":22},"30",{"key":24,"text":395,"correct":22},"40",{"key":27,"text":288,"correct":29},{"key":31,"text":292,"correct":22},{"id":399,"libraryId":5,"type":15,"typeLabel":16,"stem":400,"options":401,"answer":24,"analysis":33},932933,"下列关于通风、空调系统的布置说法中，正确的是（ ）。",[402,404,406,408],{"key":20,"text":403,"correct":22},"通风和空气调节系统，横向宜按楼层设置",{"key":24,"text":405,"correct":29},"排除含有比空气轻的可燃气体的与空气的混合物时，其排风管道应顺气流方向向上坡度敷设",{"key":27,"text":407,"correct":22},"通风和空气调节系统，竖向不宜超过6层",{"key":31,"text":409,"correct":22},"镁粉厂房循环使用净化处理后的空气，使空气中的含尘浓度低于其爆炸下限的25％之后，可再循环使用",{"id":411,"libraryId":5,"type":15,"typeLabel":16,"stem":412,"options":413,"answer":31,"analysis":33},932934,"通风和空气调节系统的排风口设置的位置应根据可燃气体、蒸气的密度不同而有所区别。比空气轻者，应设在房间的（ ）。",[414,416,418,420],{"key":20,"text":415,"correct":22},"中部或底部",{"key":24,"text":417,"correct":22},"中部或顶部",{"key":27,"text":419,"correct":22},"底部",{"key":31,"text":421,"correct":29},"顶部",{"id":423,"libraryId":5,"type":15,"typeLabel":16,"stem":424,"options":425,"answer":24,"analysis":33},932935,"某公共建筑地上10层，建筑面积6000m2。燃气锅炉房采用机械通风，该风机正常排风换气次数应不少于（ ）次／h。",[426,428,430,432],{"key":20,"text":427,"correct":22},"12",{"key":24,"text":429,"correct":29},"6",{"key":27,"text":431,"correct":22},"3",{"key":31,"text":433,"correct":22},"8",{"id":435,"libraryId":5,"type":15,"typeLabel":16,"stem":436,"options":437,"answer":27,"analysis":33},932936,"关于某电石厂房通风、空调系统的做法中，不符合现行消防技术标准的是（ ）。",[438,440,442,444],{"key":20,"text":439,"correct":22},"厂房内排出的空气不循环使用，排至室外安全地点",{"key":24,"text":441,"correct":22},"排风管采用金属管道，设置良好的导除静电的接地装置",{"key":27,"text":443,"correct":29},"设置湿式除尘器，对进入排风机的空气进行处理",{"key":31,"text":445,"correct":22},"系统的除尘器、过滤器或管道设置泄压装置",{"id":447,"libraryId":5,"type":15,"typeLabel":16,"stem":448,"options":449,"answer":31,"analysis":33},932937,"关于净化有爆炸危险粉尘的干式除尘器和过滤器的设置，做法错误的是（ ）。",[450,452,454,456],{"key":20,"text":451,"correct":22},"布置在厂房之外的独立建筑内",{"key":24,"text":453,"correct":22},"与所属厂房的防火间距为10m",{"key":27,"text":455,"correct":22},"有连续清尘设备可布置在厂房的单独房间内，但应采用耐火极限分别不低于3．00h的防火隔墙和1．50h的楼板与其他部位分隔",{"key":31,"text":457,"correct":29},"风量20000m3／h，且集尘斗的储尘量50kg的定期清灰的除尘器和过滤器，可布置在厂房的单独房间内，但应采用耐火极限分别不低于3．00h的隔墙和1．50h的楼板与其他部位分隔",{"id":459,"libraryId":5,"type":15,"typeLabel":16,"stem":460,"options":461,"answer":20,"analysis":33},932938,"下列不属于电力变压器本体的防火防爆措施的是（ ）。",[462,464,466,468],{"key":20,"text":463,"correct":29},"采用铝芯绝缘",{"key":24,"text":465,"correct":22},"防止变压器过载运行",{"key":27,"text":467,"correct":22},"保证导线接触良好",{"key":31,"text":469,"correct":22},"短路保护要可靠",{"id":471,"libraryId":5,"type":15,"typeLabel":16,"stem":472,"options":473,"answer":31,"analysis":33},932939,"直燃机房应设置火灾自动报警系统，当可燃气体浓度达到爆炸下限的（ ）时，报警系统应能及时准确报警。",[474,476,478,480],{"key":20,"text":475,"correct":22},"90％",{"key":24,"text":477,"correct":22},"75％",{"key":27,"text":479,"correct":22},"50％",{"key":31,"text":481,"correct":29},"25％",{"id":483,"libraryId":5,"type":15,"typeLabel":16,"stem":484,"options":485,"answer":24,"analysis":33},932940,"锅炉房的门应直通室外或直通安全出口，外墙开口部位的上方应设置宽度不小于（ ）m的不燃性防火挑檐或高度不小于1．2m的窗槛墙。",[486,488,490,492],{"key":20,"text":487,"correct":22},"0．5",{"key":24,"text":489,"correct":29},"1",{"key":27,"text":491,"correct":22},"1．5",{"key":31,"text":493,"correct":22},"2",{"id":495,"libraryId":5,"type":15,"typeLabel":16,"stem":496,"options":497,"answer":20,"analysis":33},932941,"净化有爆炸危险粉尘的干式除尘器和过滤器宜布置在厂房外的独立建筑内，建筑外墙与所属厂房的防火间距不应小于（ ）m。",[498,499,500,501],{"key":20,"text":218,"correct":29},{"key":24,"text":220,"correct":22},{"key":27,"text":393,"correct":22},{"key":31,"text":395,"correct":22},{"id":503,"libraryId":5,"type":84,"typeLabel":85,"stem":504,"options":505,"answer":516,"analysis":33},932942,"某综合楼，建筑高度58m，设置防排烟系统、自动喷水灭火系统、火灾自动报警系统保护，下列建筑内通风空调系统中的部位需要设置防火阀的有（ ）。",[506,508,510,512,514],{"key":20,"text":507,"correct":29},"防火分区处",{"key":24,"text":509,"correct":29},"变形缝两侧",{"key":27,"text":511,"correct":22},"办公室防火隔墙处",{"key":31,"text":513,"correct":29},"排烟机房处",{"key":97,"text":515,"correct":22},"竖向风管与每层水平风管交接处的竖向管段上","ABD",{"id":518,"libraryId":5,"type":84,"typeLabel":85,"stem":519,"options":520,"answer":531,"analysis":33},932943,"下列关于采暖系统防火防爆的说法，正确的有（）。",[521,523,525,527,529],{"key":20,"text":522,"correct":29},"黄磷制备厂房应采用不循环使用的热风采暖",{"key":24,"text":524,"correct":29},"硝化棉厂房及其应用部位严禁采用明火和电热散热器采暖",{"key":27,"text":526,"correct":22},"当采暖管道温度为100℃时，与可燃构件之间应保持不小于100mm的距离或采用不燃材料隔热",{"key":31,"text":528,"correct":22},"停车数量为100辆的汽车库需要采暖时可以采用局部采暖",{"key":97,"text":530,"correct":29},"电加热设备与送风设备的电气开关应有联锁装置，风机停转时，电加热设备也应停止工作","ABE",{"id":533,"libraryId":5,"type":84,"typeLabel":85,"stem":534,"options":535,"answer":546,"analysis":33},932944,"下列关于防火阀的说法正确的是（ ）。",[536,538,540,542,544],{"key":20,"text":537,"correct":22},"有熔断器的防火阀，其动作温度宜为280℃",{"key":24,"text":539,"correct":29},"防火阀宜靠近防火分隔处设置",{"key":27,"text":541,"correct":29},"防火阀安装时，可明装也可暗装",{"key":31,"text":543,"correct":29},"为保证防火阀能在火灾条件下发挥作用，穿过防火墙两侧各2m范围内的风管绝热材料应采用不燃材料且具备足够的刚性和抗变形能力，穿越处的空隙应用不燃材料或防火封堵材料严密填实",{"key":97,"text":545,"correct":29},"可分为防火类、防烟类、排烟类三种","BCDE",{"id":548,"libraryId":5,"type":15,"typeLabel":16,"stem":549,"options":550,"answer":20,"analysis":33},932945,"下列装修材料中，燃烧性能等级为A级的是（ ）。",[551,553,555,557],{"key":20,"text":552,"correct":29},"黏土制品",{"key":24,"text":554,"correct":22},"玻璃棉装饰吸声板",{"key":27,"text":556,"correct":22},"水泥刨花板",{"key":31,"text":558,"correct":22},"岩棉装饰板",{"id":560,"libraryId":5,"type":15,"typeLabel":16,"stem":561,"options":562,"answer":20,"analysis":33},932946,"地下汽车库进行内部装修时，隔断分隔材料应采用燃烧性能等级不低于（ ）级的材料装修。",[563,564,566,568],{"key":20,"text":20,"correct":29},{"key":24,"text":565,"correct":22},"B1",{"key":27,"text":567,"correct":22},"B2",{"key":31,"text":569,"correct":22},"B3",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":31,"analysis":33},932947,"某一级耐火等级的商场，建筑高度20m，地上4层，地下1层，一到三层为服装、珠宝购物商场，四层为KTV，全部设置自动喷水灭火系统、火灾自动报警系统保护，下列关于该KTV建筑内部装修材料选用的说法中，错误的是（ ）。",[574,576,578,580],{"key":20,"text":575,"correct":22},"顶棚可采用玻璃进行装修",{"key":24,"text":577,"correct":22},"墙面可采用纸面石膏板进行装修",{"key":27,"text":579,"correct":22},"隔断可采用难燃胶合板进行装修",{"key":31,"text":581,"correct":29},"地面可采木制人造板进行装修",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":24,"analysis":33},932948,"下列单、多层民用建筑中，当设置自动灭火系统和火灾自动报警系统时，其内部装修材料的燃烧性能等级不允许降级的是（ ）。",[586,588,590,592],{"key":20,"text":587,"correct":22},"建筑高度18m的医院病房楼房间",{"key":24,"text":589,"correct":29},"建筑高度20m的旅馆的疏散走道",{"key":27,"text":591,"correct":22},"建筑高度22m的办公楼内的办公室",{"key":31,"text":593,"correct":22},"单独建造的幼儿园午休室",{"id":595,"libraryId":5,"type":15,"typeLabel":16,"stem":596,"options":597,"answer":31,"analysis":33},932949,"某住宅建筑，建筑高度45m，与基层墙体、装饰层之间无空腔外墙外保温系统。下列保温材料中，燃烧性能符合其要求的是（ ）。",[598,600,602,604],{"key":20,"text":599,"correct":22},"EPS板",{"key":24,"text":601,"correct":22},"聚氨酯",{"key":27,"text":603,"correct":22},"XPS板",{"key":31,"text":605,"correct":29},"胶粉聚苯颗粒浆料",{"id":607,"libraryId":5,"type":15,"typeLabel":16,"stem":608,"options":609,"answer":20,"analysis":33},932950,"某建筑高度为16m的教学楼，采用与基层墙体、装饰层之间有空腔的建筑外墙外保温系统，其保温材料的燃烧性能等级不应低于（ ）级。",[610,611,612,613],{"key":20,"text":20,"correct":29},{"key":24,"text":565,"correct":22},{"key":27,"text":567,"correct":22},{"key":31,"text":569,"correct":22},{"id":615,"libraryId":5,"type":15,"typeLabel":16,"stem":616,"options":617,"answer":20,"analysis":33},932951,"某建筑高度为53m的住宅楼，采用与基层墙体、装饰层之间无空腔的外墙外保温系统，保温材料的燃烧性能为B1级，该建筑二层及以上采用不燃材料制作的防护层的厚度不应小于（ ）mm。",[618,619,620,621],{"key":20,"text":216,"correct":29},{"key":24,"text":218,"correct":22},{"key":27,"text":220,"correct":22},{"key":31,"text":222,"correct":22},[623,626,629,632,635,638],{"id":15,"name":624,"category":7,"favorite":625},"领导干部任职前廉政法规知识测试题",92,{"id":627,"name":628,"category":7,"favorite":15},595,"建筑结构与设备",{"id":630,"name":631,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":633,"name":634,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":636,"name":637,"category":7,"favorite":8},534,"BIM工程师",{"id":639,"name":637,"category":7,"favorite":8},535]