[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-24":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":636},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,24,50,2960,[13,38,52,64,76,88,100,112,121,133,145,157,169,181,193,205,217,228,240,250,262,274,286,298,310,322,334,346,358,368,380,392,404,416,428,440,452,462,474,484,499,514,529,544,558,573,588,600,612,624],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},932850,2,"多选题","在对人员疏散时间预测计算中必须确定疏散时关于（ ）等相关参数。",[19,23,26,29,32],{"key":20,"text":21,"correct":22},"A","人员数量",true,{"key":24,"text":25,"correct":22},"B","人员的行走速度",{"key":27,"text":28,"correct":22},"C","出口处人流的比流量",{"key":30,"text":31,"correct":22},"D","通道的有效宽度",{"key":33,"text":34,"correct":35},"E","人员的 心理因素",false,"ABCD","",{"id":39,"libraryId":5,"type":40,"typeLabel":41,"stem":42,"options":43,"answer":27,"analysis":37},932851,1,"单选题","耐火电缆应考虑自身在火灾时的机械强度，明敷的耐火电缆截面积应不小于（ ）mm2。",[44,46,48,50],{"key":20,"text":45,"correct":35},"0．5",{"key":24,"text":47,"correct":35},"1．5",{"key":27,"text":49,"correct":22},"2．5",{"key":30,"text":51,"correct":35},"3．5",{"id":53,"libraryId":5,"type":40,"typeLabel":41,"stem":54,"options":55,"answer":24,"analysis":37},932852,"下列关于电线电缆绝缘材料选择的说法，错误的是（ ）。",[56,58,60,62],{"key":20,"text":57,"correct":35},"普通电缆包括交联聚乙烯、普通聚氯乙烯电线电缆、橡胶电线电缆",{"key":24,"text":59,"correct":22},"阻燃电缆按燃烧时的阻燃特性可分为一般阻燃电缆、低烟低卤阻燃和无卤阻燃电缆三大类",{"key":27,"text":61,"correct":35},"阻燃电缆是指在规定试验条件下被燃烧，能使火焰蔓延仅在限定范围内，撤去火源后，残焰和残灼能在限定时间内自行熄灭的电缆",{"key":30,"text":63,"correct":35},"耐火电缆按绝缘材质可分为有机型和无机型两种",{"id":65,"libraryId":5,"type":40,"typeLabel":41,"stem":66,"options":67,"answer":30,"analysis":37},932853,"电气照明是现代照明的主要方式，电气照明往往伴随着大量的热和高温，如果安装或使用不当，极易引发火灾事故。下列关于用电设备防火的说法，正确的是（ ）。",[68,70,72,74],{"key":20,"text":69,"correct":35},"火灾危险场所照明装置可选的防护结构有隔爆型、防爆型",{"key":24,"text":71,"correct":35},"携带式照明灯具如在金属容器内及特别潮湿的场所内作业，行灯电压不得超过24V",{"key":27,"text":73,"correct":35},"每一个照明单相分支回路的电流不宜超过25A",{"key":30,"text":75,"correct":22},"可燃物品库房不应设置卤钨灯等高温照明灯具",{"id":77,"libraryId":5,"type":40,"typeLabel":41,"stem":78,"options":79,"answer":20,"analysis":37},932854,"特别潮湿场所内，行灯电压不得超过（ ）V。",[80,82,84,86],{"key":20,"text":81,"correct":22},"12",{"key":24,"text":83,"correct":35},"24",{"key":27,"text":85,"correct":35},"36",{"key":30,"text":87,"correct":35},"220",{"id":89,"libraryId":5,"type":40,"typeLabel":41,"stem":90,"options":91,"answer":27,"analysis":37},932855,"电气线路的防火对电线电缆导体材料的选择有一定的要求，非熟练人员容易接触的线路，如公共建筑与居住建筑，线芯截面面积为（ ）mm2及以下的线缆不宜选用铝芯线缆。",[92,94,96,98],{"key":20,"text":93,"correct":35},"3",{"key":24,"text":95,"correct":35},"5",{"key":27,"text":97,"correct":22},"6",{"key":30,"text":99,"correct":35},"10",{"id":101,"libraryId":5,"type":40,"typeLabel":41,"stem":102,"options":103,"answer":27,"analysis":37},932856,"浴池内设置的电气照明灯具，应采用（ ）灯具。",[104,106,108,110],{"key":20,"text":105,"correct":35},"闭合型",{"key":24,"text":107,"correct":35},"封闭型",{"key":27,"text":109,"correct":22},"密闭型",{"key":30,"text":111,"correct":35},"开放型",{"id":113,"libraryId":5,"type":40,"typeLabel":41,"stem":114,"options":115,"answer":20,"analysis":37},932857,"在特别潮湿的作业场所内，携带式照明灯具的供电电压不得超过（ ）V。",[116,117,118,119],{"key":20,"text":81,"correct":22},{"key":24,"text":83,"correct":35},{"key":27,"text":85,"correct":35},{"key":30,"text":120,"correct":35},"72",{"id":122,"libraryId":5,"type":40,"typeLabel":41,"stem":123,"options":124,"answer":24,"analysis":37},932858,"下列关于照明灯具的设置要求错误的是（ ）。",[125,127,129,131],{"key":20,"text":126,"correct":35},"照明与动力合用一电源时，应有各自的分支回路，所有照明线路均应有短路保护装置",{"key":24,"text":128,"correct":22},"携带式照明灯具（俗称行灯）的供电电压不应超过24V",{"key":27,"text":130,"correct":35},"36V以下和220V以上的电源插座应有明显区别，低压插头应无法插入较高电压的插座内",{"key":30,"text":132,"correct":35},"插座不宜和照明灯接在同一分支回路",{"id":134,"libraryId":5,"type":40,"typeLabel":41,"stem":135,"options":136,"answer":24,"analysis":37},932859,"电线电缆成束敷设时，应采用（ ）。",[137,139,141,143],{"key":20,"text":138,"correct":35},"普通电线电缆",{"key":24,"text":140,"correct":22},"阻燃型电线电缆",{"key":27,"text":142,"correct":35},"耐火电线电缆",{"key":30,"text":144,"correct":35},"矿物绝缘电线电缆",{"id":146,"libraryId":5,"type":40,"typeLabel":41,"stem":147,"options":148,"answer":24,"analysis":37},932860,"电气线路的保护措施有（ ）、过负载保护和接地故障保护。",[149,151,153,155],{"key":20,"text":150,"correct":35},"电压控制",{"key":24,"text":152,"correct":22},"短路保护",{"key":27,"text":154,"correct":35},"温度控制",{"key":30,"text":156,"correct":35},"耐火保护",{"id":158,"libraryId":5,"type":40,"typeLabel":41,"stem":159,"options":160,"answer":27,"analysis":37},932861,"关于建筑电气防火，不符合规范要求的是（）",[161,163,165,167],{"key":20,"text":162,"correct":35},"建筑供电线路应采用铜芯电缆，特殊场所可以采用铝芯电缆",{"key":24,"text":164,"correct":35},"电气线路应设置短路保护",{"key":27,"text":166,"correct":22},"照明电压不大于220v.行灯电压不大于36v.金属容器内及特别潮湿环境行灯不大于24v",{"key":30,"text":168,"correct":35},"插座和照明灯具不宜连接在同一分支回路上",{"id":170,"libraryId":5,"type":40,"typeLabel":41,"stem":171,"options":172,"answer":27,"analysis":37},932863,"水平高差大和垂直敷设的场所，应采用（ ）。",[173,175,177,179],{"key":20,"text":174,"correct":35},"普通聚氯乙烯电线电缆",{"key":24,"text":176,"correct":35},"特种聚氯乙烯电线电缆",{"key":27,"text":178,"correct":22},"橡胶电线电缆",{"key":30,"text":180,"correct":35},"交联聚乙烯电线电缆",{"id":182,"libraryId":5,"type":40,"typeLabel":41,"stem":183,"options":184,"answer":30,"analysis":37},932864,"阻燃电缆的性能主要用（ ）来评定。",[185,187,189,191],{"key":20,"text":186,"correct":35},"耐火时间",{"key":24,"text":188,"correct":35},"阻燃性能",{"key":27,"text":190,"correct":35},"柔韧性",{"key":30,"text":192,"correct":22},"发烟性和氧指数",{"id":194,"libraryId":5,"type":40,"typeLabel":41,"stem":195,"options":196,"answer":30,"analysis":37},932865,"火灾时若既需要求耐火又要满足阻燃，应采用（ ）。",[197,199,201,203],{"key":20,"text":198,"correct":35},"耐高温电缆",{"key":24,"text":200,"correct":35},"有机耐火电缆",{"key":27,"text":202,"correct":35},"阻燃电线电缆",{"key":30,"text":204,"correct":22},"矿物绝缘电缆",{"id":206,"libraryId":5,"type":40,"typeLabel":41,"stem":207,"options":208,"answer":24,"analysis":37},932866,"每一照明单相分支回路所接光源数不宜超过（ ）个。",[209,211,213,215],{"key":20,"text":210,"correct":35},"16",{"key":24,"text":212,"correct":22},"25",{"key":27,"text":214,"correct":35},"30",{"key":30,"text":216,"correct":35},"45",{"id":218,"libraryId":5,"type":40,"typeLabel":41,"stem":219,"options":220,"answer":24,"analysis":37},932867,"下列关于照明灯具的设置要求，说法错误的是（ ）。",[221,223,225,226],{"key":20,"text":222,"correct":35},"照明电压一般采用220V",{"key":24,"text":224,"correct":22},"各式荧光吸顶灯附带镇流器时可直接安装在可燃吊顶上",{"key":27,"text":126,"correct":35},{"key":30,"text":227,"correct":35},"携带式照明灯具（俗称行灯）的供电电压不应超过36V",{"id":229,"libraryId":5,"type":40,"typeLabel":41,"stem":230,"options":231,"answer":24,"analysis":37},932868,"引起电气线路火灾的因素不包括（ ）。",[232,234,236,238],{"key":20,"text":233,"correct":35},"短路",{"key":24,"text":235,"correct":22},"截面面积大",{"key":27,"text":237,"correct":35},"过载",{"key":30,"text":239,"correct":35},"接触电阻过大",{"id":241,"libraryId":5,"type":40,"typeLabel":41,"stem":242,"options":243,"answer":24,"analysis":37},932869,"爆炸性气体环境应根据爆炸性气体混合物出现的频繁程度和持续时间分为（ ）个区域等级。",[244,246,247,249],{"key":20,"text":245,"correct":35},"2",{"key":24,"text":93,"correct":22},{"key":27,"text":248,"correct":35},"4",{"key":30,"text":95,"correct":35},{"id":251,"libraryId":5,"type":40,"typeLabel":41,"stem":252,"options":253,"answer":27,"analysis":37},932870,"作为泄压设施的轻质屋面板和墙体的质量不宜大于（ ）kg／m2。",[254,256,258,260],{"key":20,"text":255,"correct":35},"40",{"key":24,"text":257,"correct":35},"50",{"key":27,"text":259,"correct":22},"60",{"key":30,"text":261,"correct":35},"80",{"id":263,"libraryId":5,"type":40,"typeLabel":41,"stem":264,"options":265,"answer":20,"analysis":37},932871,"下列场所中，可以与贴邻的配电站之间开设采用不燃材料制作且不能开启的甲级防火窗作为观察窗的是（ ）。",[266,268,270,272],{"key":20,"text":267,"correct":22},"氨压缩机房",{"key":24,"text":269,"correct":35},"乙炔站",{"key":27,"text":271,"correct":35},"天然气站",{"key":30,"text":273,"correct":35},"氢气站",{"id":275,"libraryId":5,"type":40,"typeLabel":41,"stem":276,"options":277,"answer":24,"analysis":37},932872,"下列关于泄压面的说法，错误的是（ ）。",[278,280,282,284],{"key":20,"text":279,"correct":35},"泄压面的设置应避开人员集中的场所和主要交通道路",{"key":24,"text":281,"correct":22},"泄压面的设置宜远离容易发生爆炸的部位",{"key":27,"text":283,"correct":35},"泄压面在材料的选择上要求质量轻",{"key":30,"text":285,"correct":35},"泄压面的材料最好具有在爆炸时易破碎成碎块的特点",{"id":287,"libraryId":5,"type":40,"typeLabel":41,"stem":288,"options":289,"answer":24,"analysis":37},932873,"有爆炸危险的区域内的楼梯间、室外楼梯或有爆炸危险的区域与相邻区域连通处，应设置门斗防护措施，门斗的门应采用（ ）。",[290,292,294,296],{"key":20,"text":291,"correct":35},"耐火完整性不低于2．00h，耐火隔热性不低于1．00h的防火门",{"key":24,"text":293,"correct":22},"耐火完整性和耐火隔热性均不低于1．50h的防火门",{"key":27,"text":295,"correct":35},"耐火完整性不低于1．00h，耐火隔热性不低于2．00h的防火门",{"key":30,"text":297,"correct":35},"耐火完整性不低于0．50h，耐火隔热性不低于1．00h的防火门",{"id":299,"libraryId":5,"type":40,"typeLabel":41,"stem":300,"options":301,"answer":24,"analysis":37},932874,"下列关于爆炸性气体混合物的分级、分组说法，错误的是（ ）。",[302,304,306,308],{"key":20,"text":303,"correct":35},"最大试验安全间隙中，间隙越小，危险性越大",{"key":24,"text":305,"correct":22},"按最小点燃电流分级，ⅡA危险性最大",{"key":27,"text":307,"correct":35},"按最小点燃电流分级，点燃电流越大，危险性越小",{"key":30,"text":309,"correct":35},"按照最大试验间隙分级，ⅡC的安全间隙最小",{"id":311,"libraryId":5,"type":40,"typeLabel":41,"stem":312,"options":313,"answer":30,"analysis":37},932875,"爆炸性气体混合物应按引燃温度分组，下列组别中引燃温度最低的是（ ）。",[314,316,318,320],{"key":20,"text":315,"correct":35},"T1",{"key":24,"text":317,"correct":35},"T3",{"key":27,"text":319,"correct":35},"T5",{"key":30,"text":321,"correct":22},"T6",{"id":323,"libraryId":5,"type":40,"typeLabel":41,"stem":324,"options":325,"answer":27,"analysis":37},932876,"爆炸性粉尘混合物根据粉尘的特性可分为Ⅲ A、Ⅲ B、ⅢC三级。下列爆炸性粉尘混合物属于ⅢB级的是（ ）。",[326,328,330,332],{"key":20,"text":327,"correct":35},"木质纤维",{"key":24,"text":329,"correct":35},"煤",{"key":27,"text":331,"correct":22},"木料粉末",{"key":30,"text":333,"correct":35},"石墨粉",{"id":335,"libraryId":5,"type":40,"typeLabel":41,"stem":336,"options":337,"answer":27,"analysis":37},932877,"某防爆电气设备的防爆标志为Ex（ib）ⅡCT5，其中T5代表（ ）。",[338,340,342,344],{"key":20,"text":339,"correct":35},"爆炸性气体的级别",{"key":24,"text":341,"correct":35},"电气设备的设备类别",{"key":27,"text":343,"correct":22},"电气设备的温度组别",{"key":30,"text":345,"correct":35},"防爆形式",{"id":347,"libraryId":5,"type":40,"typeLabel":41,"stem":348,"options":349,"answer":24,"analysis":37},932878,"仅按照释放源的级别划分，下列爆炸性气体环境的危险区域属于1区的是（ ）。",[350,352,354,356],{"key":20,"text":351,"correct":35},"油、水分离器等直接与空间接触的可燃液体的表面",{"key":24,"text":353,"correct":22},"正常运行时，会向空间中释放可燃物质的取样点",{"key":27,"text":355,"correct":35},"正常运行时不能释放可燃物质的法兰、连接件和管道接头",{"key":30,"text":357,"correct":35},"没有用惰性气体覆盖的固定顶盖储罐中的可燃液体表面",{"id":359,"libraryId":5,"type":40,"typeLabel":41,"stem":360,"options":361,"answer":27,"analysis":37},932879,"连续级释放源是指连续释放或预计长期释放的释放源。下列情况中，可划为连续级释放源的是（ ）。",[362,363,365,366],{"key":20,"text":353,"correct":35},{"key":24,"text":364,"correct":35},"正常运行时，会向空间中释放可燃物质的排气口",{"key":27,"text":351,"correct":22},{"key":30,"text":367,"correct":35},"储存有可燃液体的容器上的排水口处，在正常运行中，当水排掉时，该处可能会向空间中释放可燃物质",{"id":369,"libraryId":5,"type":40,"typeLabel":41,"stem":370,"options":371,"answer":27,"analysis":37},932880,"下列关于厂房、仓库防爆技术措施的说法，不正确的是（）。",[372,374,376,378],{"key":20,"text":373,"correct":35},"散发较空气轻的可燃气体、可燃蒸气的甲类厂房，宜采用轻质屋面板作为泄压面积",{"key":24,"text":375,"correct":35},"使用和生产甲、乙、丙类液体的厂房，其管、沟不应与相邻厂房的管、沟相通，下水道应设置隔油设施",{"key":27,"text":377,"correct":22},"甲、乙、丙类液体仓库设置地沟时，其盖板应严密",{"key":30,"text":379,"correct":35},"散发较空气重的可燃气体、可燃蒸气的甲类厂房和有粉尘、纤维爆炸危险的乙类厂房应采用不发火花的地面",{"id":381,"libraryId":5,"type":40,"typeLabel":41,"stem":382,"options":383,"answer":24,"analysis":37},932881,"下列关于有爆炸危险性区域或场所布置的说法，不正确的是（）。",[384,386,388,390],{"key":20,"text":385,"correct":35},"有爆炸危险区域内的楼梯间、室外楼梯或有爆炸危险的区域与相邻区域连通处，应设置门斗",{"key":24,"text":387,"correct":22},"有爆炸危险的多层甲、乙、丙类生产部位，宜布置在厂房靠外墙的泄压设施附近",{"key":27,"text":389,"correct":35},"有爆炸危险的设备宜避开厂房的梁、柱等主要承重构件布置",{"key":30,"text":391,"correct":35},"有爆炸危险的甲、乙类厂房的总控制室应独立设置",{"id":393,"libraryId":5,"type":40,"typeLabel":41,"stem":394,"options":395,"answer":30,"analysis":37},932882,"某镁粉厂房长宽高分别为 18m、12m、6.5m，泄压比 C=0.11 ㎡\u002Fm3，该厂房需要的泄压面积至少为（ ）。",[396,398,400,402],{"key":20,"text":397,"correct":35},"125",{"key":24,"text":399,"correct":35},"111",{"key":27,"text":401,"correct":35},"136",{"key":30,"text":403,"correct":22},"138",{"id":405,"libraryId":5,"type":40,"typeLabel":41,"stem":406,"options":407,"answer":27,"analysis":37},932883,"根据现行国家标准《爆炸危险环境电力装置设计规范》（GB50058-2014）的规定，21 区属于（ ）。",[408,410,412,414],{"key":20,"text":409,"correct":35},"在正常运行时可能出现爆炸性气体混合物的环境",{"key":24,"text":411,"correct":35},"在正常运行时不可能出现爆炸性气体混合物的环境",{"key":27,"text":413,"correct":22},"在正常运行时，空气中的可燃性粉尘云很可能偶尔出现于爆炸性环境中",{"key":30,"text":415,"correct":35},"在正常运行时，空气中的可燃性粉尘云一般不可能出现于爆炸性环境中",{"id":417,"libraryId":5,"type":40,"typeLabel":41,"stem":418,"options":419,"answer":30,"analysis":37},932884,"下列电气设备的基本防爆型式仅适用于 2 区危险环境的是（ ）",[420,422,424,426],{"key":20,"text":421,"correct":35},"隔爆型",{"key":24,"text":423,"correct":35},"油浸型",{"key":27,"text":425,"correct":35},"正压型",{"key":30,"text":427,"correct":22},"无火花型",{"id":429,"libraryId":5,"type":40,"typeLabel":41,"stem":430,"options":431,"answer":30,"analysis":37},932885,"下列不可做泄压设施的为（ ）。",[432,434,436,438],{"key":20,"text":433,"correct":35},"轻质屋面板",{"key":24,"text":435,"correct":35},"轻质墙体",{"key":27,"text":437,"correct":35},"泄压窗",{"key":30,"text":439,"correct":22},"普通玻璃",{"id":441,"libraryId":5,"type":40,"typeLabel":41,"stem":442,"options":443,"answer":27,"analysis":37},932886,"下列不属于电气防爆基本措施的是（ ）。",[444,446,448,450],{"key":20,"text":445,"correct":35},"采用防爆的电气设备",{"key":24,"text":447,"correct":35},"设置漏电火灾报警和紧急断电装置",{"key":27,"text":449,"correct":22},"严格控制电气设备的温度",{"key":30,"text":451,"correct":35},"宜将正常运行时产生火花、电弧和危险温度的电气设备和线路，布置在爆炸危险性较小或没有爆炸危险的环境内",{"id":453,"libraryId":5,"type":40,"typeLabel":41,"stem":454,"options":455,"answer":27,"analysis":37},932887,"为了减少爆炸损失，作为泄压设施的轻质屋面板的单位面积质量不宜超过（ ）kg／m2。",[456,458,459,460],{"key":20,"text":457,"correct":35},"20",{"key":24,"text":255,"correct":35},{"key":27,"text":259,"correct":22},{"key":30,"text":461,"correct":35},"100",{"id":463,"libraryId":5,"type":40,"typeLabel":41,"stem":464,"options":465,"answer":20,"analysis":37},932888,"在正常运行情况下，爆炸性气体混合物连续出现或长期出现的场所称为（ ）。",[466,468,470,472],{"key":20,"text":467,"correct":22},"0区",{"key":24,"text":469,"correct":35},"1区",{"key":27,"text":471,"correct":35},"2区",{"key":30,"text":473,"correct":35},"20区",{"id":475,"libraryId":5,"type":40,"typeLabel":41,"stem":476,"options":477,"answer":27,"analysis":37},932889,"下列选项中，适用于0区的防爆电气设备的形式是（ ）。",[478,479,481,483],{"key":20,"text":421,"correct":35},{"key":24,"text":480,"correct":35},"增安型",{"key":27,"text":482,"correct":22},"ia级本质安全型",{"key":30,"text":425,"correct":35},{"id":485,"libraryId":5,"type":15,"typeLabel":16,"stem":486,"options":487,"answer":498,"analysis":37},932890,"下列厂房的管、沟不应与相邻厂房管、沟相通的有（ ）。",[488,490,492,494,496],{"key":20,"text":489,"correct":35},"氧气站",{"key":24,"text":491,"correct":35},"空分厂房",{"key":27,"text":493,"correct":35},"车辆装配厂",{"key":30,"text":495,"correct":22},"沥青加工厂房",{"key":33,"text":497,"correct":22},"氯乙醇厂房","DE",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":513,"analysis":37},932891,"下列关于厂房仓库防爆的说法，正确的有（ ）。",[503,505,507,509,511],{"key":20,"text":504,"correct":35},"厂房内不宜设置地沟，必须设置时，其盖板应严密",{"key":24,"text":506,"correct":35},"使用和生产甲、乙、丙类液体厂房的管、沟，当满足一定设备条件时可以与相邻厂房的管、沟相通",{"key":27,"text":508,"correct":22},"散发较空气重的可燃气体、可燃蒸气的甲类厂房和有粉尘、纤维爆炸危险的乙类厂房地沟应采取防止可燃气体、可燃蒸气和粉尘、纤维在地沟积聚的有效措施",{"key":30,"text":510,"correct":22},"甲、乙、丙类液体仓库应设置防止液体流散的设施",{"key":33,"text":512,"correct":35},"使用和生产甲、乙、丙类液体厂房的下水道应设置除尘设施","CD",{"id":515,"libraryId":5,"type":15,"typeLabel":16,"stem":516,"options":517,"answer":528,"analysis":37},932892,"对于有爆炸危险的厂房和库房，选择正确的结构形式，再选用耐火性能好、抗爆能力强的框架结构，可以在发生火灾爆炸事故时有效地防止建筑结构发生倒塌破坏，减轻甚至避免造成的危害和损失。耐爆框架结构一般为（ ）。",[518,520,522,524,526],{"key":20,"text":519,"correct":22},"现浇式钢筋混凝土框架结构",{"key":24,"text":521,"correct":22},"装配式钢筋混凝土框架结构",{"key":27,"text":523,"correct":35},"砖混结构",{"key":30,"text":525,"correct":35},"砖木结构",{"key":33,"text":527,"correct":22},"钢框架结构","ABE",{"id":530,"libraryId":5,"type":15,"typeLabel":16,"stem":531,"options":532,"answer":543,"analysis":37},932893,"下列关于防爆电气设备选用原则的说法，正确的有（ ）。",[533,535,537,539,541],{"key":20,"text":534,"correct":22},"电气设备的防爆型式应与爆炸危险区域相适应",{"key":24,"text":536,"correct":22},"电气设备的防爆性能应与爆炸危险环境物质的危险性相适应",{"key":27,"text":538,"correct":35},"同时存在爆炸性气体和可燃性粉尘混合的环境，应按爆炸性气体的标准来选择电气设备的防爆性能",{"key":30,"text":540,"correct":22},"电气设备的选择应与环境条件相适应",{"key":33,"text":542,"correct":22},"应符合整体防爆的原则，安全可靠、经济合理、使用维修方便","ABDE",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":528,"analysis":37},932894,"下列关于爆炸危险性厂房、库房的布置，说法正确的是（ ）。",[548,550,552,554,556],{"key":20,"text":549,"correct":22},"有爆炸危险的甲、乙类厂房、库房宜独立设置，并宜采用敞开或半敞开式",{"key":24,"text":551,"correct":22},"甲类厂房与民用建筑裙房的防火间距不应小于25m",{"key":27,"text":553,"correct":35},"有爆炸危险的厂房平面布置最好采用矩形，与主导风向垂直或夹角不大于45°",{"key":30,"text":555,"correct":35},"相邻两个厂房之间应直接有门相通",{"key":33,"text":557,"correct":22},"在山区，宜布置在迎风山坡一面且通风良好的地方",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":572,"analysis":37},932895,"下列属于防爆墙的做法的是（ ）。",[562,564,566,568,570],{"key":20,"text":563,"correct":35},"纯混凝土墙",{"key":24,"text":565,"correct":22},"钢筋混凝土墙",{"key":27,"text":567,"correct":22},"砖墙配筋",{"key":30,"text":569,"correct":22},"夹砂钢木板",{"key":33,"text":571,"correct":35},"纯砖墙","BCD",{"id":574,"libraryId":5,"type":15,"typeLabel":16,"stem":575,"options":576,"answer":587,"analysis":37},932896,"下列关于电气防爆基本措施的叙述中，正确的是（）。",[577,579,581,583,585],{"key":20,"text":578,"correct":22},"在满足工艺生产及安全的前提下，应减少防爆电气设备的数量。如无特殊需要，不宜采用携带式电气设备",{"key":24,"text":580,"correct":35},"散发较空气重的可燃气体、可燃蒸气的甲类厂房以及有粉尘、纤维爆炸危险的乙类厂房，应采用安装静电消除装置的地面",{"key":27,"text":582,"correct":22},"按有关电力设备接地设计技术规程规定，一般情况下不需要接地的部分，在爆炸危险区域内仍应接地，电气设备的金属外壳应可靠接地",{"key":30,"text":584,"correct":22},"设置漏电火灾报警和紧急断电装置，在电气设备可能出现故障之前，采取相应补救措施或自动切断爆炸危险区域电源",{"key":33,"text":586,"correct":22},"宜将正常运行时产生火花、电弧和危险温度的电气设备和线路，布置在爆炸危险性较小或者没有爆炸危险的环境内","ACDE",{"id":589,"libraryId":5,"type":40,"typeLabel":41,"stem":590,"options":591,"answer":27,"analysis":37},932897,"下列建筑防爆的基本措施中，属于减轻性技术措施的是（ ）。",[592,594,596,598],{"key":20,"text":593,"correct":35},"减少使用爆炸危险可燃物质",{"key":24,"text":595,"correct":35},"生产设备应尽可能保持密闭状态",{"key":27,"text":597,"correct":22},"设置泄压窗",{"key":30,"text":599,"correct":35},"消除静电火花",{"id":601,"libraryId":5,"type":40,"typeLabel":41,"stem":602,"options":603,"answer":30,"analysis":37},932898,"按照国家标准《爆炸危险环境电力装置设计规范》（GB 50058-2014）的规定，爆炸性粉尘环境按其出现的频繁程度和持续时间可分为3个区域等级，其中22区指的是在正常运行时，空气中的可燃粉尘云（ ）出现于爆炸性环境中。",[604,606,608,610],{"key":20,"text":605,"correct":35},"很可能长期",{"key":24,"text":607,"correct":35},"很可能频繁",{"key":27,"text":609,"correct":35},"很可能偶尔",{"key":30,"text":611,"correct":22},"一般不可能",{"id":613,"libraryId":5,"type":40,"typeLabel":41,"stem":614,"options":615,"answer":27,"analysis":37},932899,"甲、乙、丙类液体仓库防止液体流散的基本做法是在桶装仓库门洞处修筑漫坡，一般高为（ ）mm。",[616,618,620,622],{"key":20,"text":617,"correct":35},"200～300",{"key":24,"text":619,"correct":35},"150～200",{"key":27,"text":621,"correct":22},"150～300",{"key":30,"text":623,"correct":35},"150～400",{"id":625,"libraryId":5,"type":40,"typeLabel":41,"stem":626,"options":627,"answer":27,"analysis":37},932900,"某耐火等级为一级的煤粉厂房，地上1层，高度为6m，建筑布置为长方形，长边为50m，短边为20m，则该厂房所需的泄压面积不应小于（ ）m2。（煤粉C值≥0．055，60002\u002F3=330．19．30002\u002F3=208．01）",[628,630,632,634],{"key":20,"text":629,"correct":35},"89．741",{"key":24,"text":631,"correct":35},"114．405",{"key":27,"text":633,"correct":22},"228．81",{"key":30,"text":635,"correct":35},"324．51",[637,640,643,646,649,652],{"id":40,"name":638,"category":7,"favorite":639},"领导干部任职前廉政法规知识测试题",92,{"id":641,"name":642,"category":7,"favorite":40},595,"建筑结构与设备",{"id":644,"name":645,"category":7,"favorite":40},715,"招标采购专业知识与法律法规",{"id":647,"name":648,"category":7,"favorite":40},848,"市政方向-通用基础",{"id":650,"name":651,"category":7,"favorite":8},534,"BIM工程师",{"id":653,"name":651,"category":7,"favorite":8},535]