[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-23":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":633},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,23,50,2960,[13,34,46,58,70,82,94,106,118,130,142,154,165,173,185,195,207,218,230,242,252,264,276,288,300,312,324,336,348,358,370,380,392,404,416,427,439,447,459,471,483,495,513,528,543,558,573,588,603,618],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},932800,1,"单选题","下列关于住宅建筑安全出口的设置要求说法正确的是（ ）。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","一类高层住宅建筑，每个单元每层的安全出口不应少于1个",false,{"key":24,"text":25,"correct":22},"B","建筑高度不大于27m的住宅建筑每个单元每层设置一个安全出口",{"key":27,"text":28,"correct":22},"C","二类高层住宅建筑每个单元设置一座疏散楼梯时，疏散楼梯应相互连通且户门防火门等级应为丙级",{"key":30,"text":31,"correct":32},"D","二类高层住宅建筑每单元任一层的建筑面积大于650m2，或任一户门至最近安全出口的距离大于10m时，每个单元每层安全出口不应少于2个",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":27,"analysis":33},932801,"下列关于室外楼梯作为疏散楼梯的说法错误的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"楼梯和疏散出口平台均应采取不燃材料制作",{"key":24,"text":41,"correct":22},"倾斜度不应大于45°",{"key":27,"text":43,"correct":32},"栏杆扶手的高度和楼梯的净宽度不应小于1．0m",{"key":30,"text":45,"correct":22},"通向室外楼梯的门宜采用乙级防火门，并应向外开启",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":27,"analysis":33},932802,"建筑高度超过（ ）的公共建筑和住宅建筑应设置避难层。",[50,52,54,56],{"key":20,"text":51,"correct":22},"50m",{"key":24,"text":53,"correct":22},"80m",{"key":27,"text":55,"correct":32},"100m",{"key":30,"text":57,"correct":22},"120m",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},932803,"在进行疏散楼梯的平面布置时，下列不属于应满足的防火要求的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"疏散楼梯宜设置在标准层的两端",{"key":24,"text":65,"correct":32},"疏散楼梯宜靠中间设置",{"key":27,"text":67,"correct":22},"疏散楼梯宜靠近电梯设置",{"key":30,"text":69,"correct":22},"疏散楼梯宜靠外墙设置",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":20,"analysis":33},932804,"室外楼梯的适用范围不包括（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":32},"商场",{"key":24,"text":77,"correct":22},"甲、乙、丙类厂房",{"key":27,"text":79,"correct":22},"建筑高度大于32m且任一层人数超过10人的厂房",{"key":30,"text":81,"correct":22},"辅助防烟楼梯",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":30,"analysis":33},932805,"某一级耐火等级的医疗中心，建筑高度25m，疏散走道采用双面布房，则该医院疏散走道的最小净宽度不应小于（ ）m。",[86,88,90,92],{"key":20,"text":87,"correct":22},"1．2",{"key":24,"text":89,"correct":22},"1．3",{"key":27,"text":91,"correct":22},"1． 4",{"key":30,"text":93,"correct":32},"1．5",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":24,"analysis":33},932806,"某二级耐火等级的教学楼，全部设置了自动喷水灭火系统，建筑高度21m，在疏散走道居中部位设两座封闭楼梯间。该走道尽端的教室内任一点至疏散楼梯间入口的最大允许距离为（ ）m。",[98,100,102,104],{"key":20,"text":99,"correct":22},"44",{"key":24,"text":101,"correct":32},"55",{"key":27,"text":103,"correct":22},"49．5",{"key":30,"text":105,"correct":22},"40",{"id":107,"libraryId":5,"type":15,"typeLabel":16,"stem":108,"options":109,"answer":27,"analysis":33},932807,"某民用建筑，地上12层，层高4．2m，一至三层为商场，四层及以上为住宅，下列关于该建筑防火设计的做法，正确的是（ ）。",[110,112,114,116],{"key":20,"text":111,"correct":22},"该建筑为二类高层住宅建筑",{"key":24,"text":113,"correct":22},"该商场与住宅建筑之间采用不低于2．00h且无门、窗、洞口的防火隔墙与1．50h的不燃性楼板进行完全分隔",{"key":27,"text":115,"correct":32},"该商场的防火分区建筑面积为2500m2",{"key":30,"text":117,"correct":22},"住宅部分与商场共用2部防烟楼梯间",{"id":119,"libraryId":5,"type":15,"typeLabel":16,"stem":120,"options":121,"answer":20,"analysis":33},932808,"某民用建筑，地上12层，一层到三层为商场，四层为网吧，四层以上为住宅建筑，商业建筑层高5m，住宅建筑层高3m。下列关于该建筑设计的说法，正确的是（ ）。",[122,124,126,128],{"key":20,"text":123,"correct":32},"住宅部分与非住宅部分的疏散楼梯分别独立设置，住宅部分设防烟楼梯间，非住宅部分设封闭楼梯间",{"key":24,"text":125,"correct":22},"住宅采用一级消防负荷用电，商业建筑采用二级消防负荷用电",{"key":27,"text":127,"correct":22},"住宅部分与商业部分之间采用2．00h的防火隔墙与1．50h的楼板分隔",{"key":30,"text":129,"correct":22},"网吧设置火灾自动报警系统与自动喷水灭火系统，每个厅、室面积为400m2",{"id":131,"libraryId":5,"type":15,"typeLabel":16,"stem":132,"options":133,"answer":24,"analysis":33},932809,"某独立建造的地下家具商场，其地下一层的人员密度应按（ ）人／m2确定。",[134,136,138,140],{"key":20,"text":135,"correct":22},"0．168",{"key":24,"text":137,"correct":32},"0．18",{"key":27,"text":139,"correct":22},"0．56",{"key":30,"text":141,"correct":22},"0．60",{"id":143,"libraryId":5,"type":15,"typeLabel":16,"stem":144,"options":145,"answer":30,"analysis":33},932810,"在计算歌舞娱乐游艺放映场所的疏散总净宽度时，网吧的疏散人数应按厅、室的建筑面积不小于（ ）m2／人计算。",[146,148,150,152],{"key":20,"text":147,"correct":22},"0．5",{"key":24,"text":149,"correct":22},"0．6",{"key":27,"text":151,"correct":22},"1．0",{"key":30,"text":153,"correct":32},"2",{"id":155,"libraryId":5,"type":15,"typeLabel":16,"stem":156,"options":157,"answer":27,"analysis":33},932811,"某二级耐火等级的乙类厂房，地上2层，地上一、二层的设计疏散人数分别为100人、110人，则厂房二层疏散走道的总净宽度不应小于（ ）m。",[158,160,161,163],{"key":20,"text":159,"correct":22},"1．1",{"key":24,"text":87,"correct":22},{"key":27,"text":162,"correct":32},"1．4",{"key":30,"text":164,"correct":22},"1．6",{"id":166,"libraryId":5,"type":15,"typeLabel":16,"stem":167,"options":168,"answer":20,"analysis":33},932812,"某建筑高度为27m的综合楼，办公室沿疏散走道两侧布置，则该综合楼的首层疏散外门的最小疏散净宽度不应小于（ ）m。",[169,170,171,172],{"key":20,"text":87,"correct":32},{"key":24,"text":89,"correct":22},{"key":27,"text":162,"correct":22},{"key":30,"text":93,"correct":22},{"id":174,"libraryId":5,"type":15,"typeLabel":16,"stem":175,"options":176,"answer":30,"analysis":33},932813,"某一级耐火等级的剧场，建筑高度16m，共3层，可容纳2000人，则该剧场供观众疏散的楼梯最小疏散总净宽度不应小于（ ）m。",[177,179,181,183],{"key":20,"text":178,"correct":22},"9",{"key":24,"text":180,"correct":22},"12",{"key":27,"text":182,"correct":22},"14",{"key":30,"text":184,"correct":32},"15",{"id":186,"libraryId":5,"type":15,"typeLabel":16,"stem":187,"options":188,"answer":20,"analysis":33},932814,"某一级耐火等级综合楼，地上4层，地下2层，层高4m，首层设计疏散人数为800人，地下一层设计疏散人数为1200人，地下二层设计疏散人数为1500人，则地下一层到首层疏散楼梯的最小疏散总净宽度不应小于（ ）m。",[189,191,193,194],{"key":20,"text":190,"correct":32},"11．25",{"key":24,"text":192,"correct":22},"9．0",{"key":27,"text":184,"correct":22},{"key":30,"text":180,"correct":22},{"id":196,"libraryId":5,"type":15,"typeLabel":16,"stem":197,"options":198,"answer":27,"analysis":33},932815,"某建材商场建筑高度为15m，地上3层，耐火等级为二级，主要经营瓷砖、家具和各种灯饰，每层建筑面积为6000m2，建筑内全部设置了自动喷水灭火系统，建材商场人员密度按0．20人／m2计算。利用防火墙将该建材商场第二层平均划分为 A、B两个防火分区，A防火分区利用通向B防火分区的甲级防火门，则A防火分区直通室外的安全出口的最小净宽度为（ ）m。",[199,201,203,205],{"key":20,"text":200,"correct":22},"4．5",{"key":24,"text":202,"correct":22},"1．35",{"key":27,"text":204,"correct":32},"3．15",{"key":30,"text":206,"correct":22},"6",{"id":208,"libraryId":5,"type":15,"typeLabel":16,"stem":209,"options":210,"answer":30,"analysis":33},932816,"住宅建筑每层相邻两个疏散门最近边缘之间的水平距离符合规定的是（ ）m。",[211,212,214,216],{"key":20,"text":153,"correct":22},{"key":24,"text":213,"correct":22},"3",{"key":27,"text":215,"correct":22},"4",{"key":30,"text":217,"correct":32},"5",{"id":219,"libraryId":5,"type":15,"typeLabel":16,"stem":220,"options":221,"answer":24,"analysis":33},932817,"某教学建筑位于两个安全出口之间的房间仅设置1个疏散门时，该房间的建筑面积不应大于（ ）m2。",[222,224,226,228],{"key":20,"text":223,"correct":22},"50",{"key":24,"text":225,"correct":32},"75",{"key":27,"text":227,"correct":22},"90",{"key":30,"text":229,"correct":22},"120",{"id":231,"libraryId":5,"type":15,"typeLabel":16,"stem":232,"options":233,"answer":20,"analysis":33},932818,"下列建筑中，可采用敞开楼梯间的是（ ）。",[234,236,238,240],{"key":20,"text":235,"correct":32},"某建筑高度33m住宅楼，户门采用乙级防火门",{"key":24,"text":237,"correct":22},"某建筑高度27m丙类厂房，疏散门采用乙级防火门",{"key":27,"text":239,"correct":22},"某裙房，采用防火卷帘与高屋建筑主体分隔，其疏散门采用乙级防火门",{"key":30,"text":241,"correct":22},"某多层乙类厂房，疏散门采用乙级防火门",{"id":243,"libraryId":5,"type":15,"typeLabel":16,"stem":244,"options":245,"answer":30,"analysis":33},932819,"某二级耐火等级的展览厅，地上3层，每层建筑面积2500m2，采用自动喷水灭火系统、火灾自动报警系统保护，每层在建筑两侧均设有安全出口，则该展览厅室内任意一点到最近安全出口的直线距离不应大于（ ）m。",[246,248,250,251],{"key":20,"text":247,"correct":22},"10",{"key":24,"text":249,"correct":22},"30",{"key":27,"text":105,"correct":22},{"key":30,"text":223,"correct":32},{"id":253,"libraryId":5,"type":15,"typeLabel":16,"stem":254,"options":255,"answer":24,"analysis":33},932820,"某二级耐火等级的多层沥青加工厂房，地上4层，每层建筑面积2300m2，使用人数不超过140人，下列关于该厂房安全疏散的设计，错误的是（ ）。",[256,258,260,262],{"key":20,"text":257,"correct":22},"设置2部楼梯净宽度为1．3m的封闭楼梯间",{"key":24,"text":259,"correct":32},"首层疏散门靠外墙采用防火卷帘门",{"key":27,"text":261,"correct":22},"厂房内任一点至最近安全出口的直线距离为31m",{"key":30,"text":263,"correct":22},"厂房疏散走道的总净宽度为2．8m",{"id":265,"libraryId":5,"type":15,"typeLabel":16,"stem":266,"options":267,"answer":20,"analysis":33},932821,"下列关于疏散宽度的说法，错误的是（ ）。",[268,270,272,274],{"key":20,"text":269,"correct":32},"某3层剧场，其建筑内部疏散门、安全出口、疏散走道和疏散楼梯的百人疏散宽度指标均按0．75选取",{"key":24,"text":271,"correct":22},"礼堂的出入大厅，其疏散总净宽应按照计算确定，但其最小净宽度不应小于1．4m",{"key":27,"text":273,"correct":22},"某KTV设置在地下一层，其与地面出入口的高差为3．5m，设计总人数为200人，其独立设置的疏散楼梯净宽度为2.2m",{"key":30,"text":275,"correct":22},"某三级甲等医院病房楼，建筑高度为64m，采用双面布房，其内部的疏散走道的疏散总净宽应按照计算确定，但其最小宽度不应小于1．5m",{"id":277,"libraryId":5,"type":15,"typeLabel":16,"stem":278,"options":279,"answer":30,"analysis":33},932822,"某建筑高度为96m的五星级酒店，集休闲娱乐、餐饮、住宿为一体，其中首层和二层为大堂和酒店奢侈品专卖店，三层和四层为酒店办公区域，地下一层设置了KTV，其内部卡拉OK包间均需要通过疏散走道通至疏散楼梯间。下列建筑内设计做法中，错误的是（ ）。",[280,282,284,286],{"key":20,"text":281,"correct":22},"客房楼层疏散走道的吊顶采用耐火极限为0．25h的不燃性石膏板",{"key":24,"text":283,"correct":22},"办公区疏散走道两侧墙体采用轻质混凝土砌块，耐火极限为2．0h",{"key":27,"text":285,"correct":22},"客房部分疏散走道百人疏散宽度指标按1m／百人确定",{"key":30,"text":287,"correct":32},"KTV袋形疏散走道两侧的疏散门至最近安全出口的距离为15m",{"id":289,"libraryId":5,"type":15,"typeLabel":16,"stem":290,"options":291,"answer":30,"analysis":33},932823,"为了满足高层病房楼和手术室中难以在火灾时及时疏散的人员的避难需要和保证其避难安全，高层病房楼层需要按照要求设置避难间，下列关于避难间的说法中符合现行国家消防技术标准的是（ ）。",[292,294,296,298],{"key":20,"text":293,"correct":22},"避难间应靠近楼梯间，并应采用耐火极限不低于2．0h的防火隔墙和乙级防火门与其他部位分隔",{"key":24,"text":295,"correct":22},"避难间服务的护理单元不应超过3个，其净面积应按每个护理单元不小于25．0m2确定",{"key":27,"text":297,"correct":22},"避难间应设置直接对外的可开启窗口或独立的机械排烟设施，外窗应采用乙级防火窗",{"key":30,"text":299,"correct":32},"避难间兼作其他用途，可以利用电梯前室，只要不减少可供避难的净面积就可以",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":30,"analysis":33},932824,"下列建筑中其内疏散走道和主要疏散路线的地面上需要增设能保持视觉连续的灯光疏散指示标志或蓄光疏散指示标志的是（ ）。",[304,306,308,310],{"key":20,"text":305,"correct":22},"总建筑面积为5000m2的展览建筑",{"key":24,"text":307,"correct":22},"总建筑面积为3000m2的地上商店",{"key":27,"text":309,"correct":22},"座位数为1500个的电影院",{"key":30,"text":311,"correct":32},"某建筑面积仅为500m2的夜总会",{"id":313,"libraryId":5,"type":15,"typeLabel":16,"stem":314,"options":315,"answer":30,"analysis":33},932825,"某多功能建筑，建筑高度为54．8m，2座楼梯间分别位于“一”字形内走廊的尽端，楼梯间形式和疏散宽度符合相关规范规定。地下一层建筑面积为2600m2，用途为餐厅、设备房；地上共14层，建筑面积为24000m2，用途为歌舞娱乐、宾馆、办公。该建筑按照规范要求设置建筑消防设施。下列关于该建筑房间疏散门的设置中，错误的是（ ）。",[316,318,320,322],{"key":20,"text":317,"correct":22},"九至十四层每层的会议室相邻两个疏散门最近边缘之间的水平距离为6m",{"key":24,"text":319,"correct":22},"位于地下一层的一个建筑面积为50m2、使用人数为10人的小餐厅，设置1个向内开启的疏散门",{"key":27,"text":321,"correct":22},"位于三层的一个建筑面积为80m2、使用人数为50人的会议室，设置2个向内开启的疏散门",{"key":30,"text":323,"correct":32},"位于一层的一个建筑面积为60m2、使用人数为37人的录像厅，设置1个向内开启的疏散门",{"id":325,"libraryId":5,"type":15,"typeLabel":16,"stem":326,"options":327,"answer":27,"analysis":33},932826,"某高层病房楼在二层及以上的病房楼层和洁净手术室设置有避难间，避难间靠近楼梯间，除了采用甲级防火门与其他部位分隔外，还应采用（ ）与其他部位分隔。",[328,330,332,334],{"key":20,"text":329,"correct":22},"耐火极限不低于1．50h的不燃性楼板",{"key":24,"text":331,"correct":22},"耐火极限不低于3．00h的防火墙",{"key":27,"text":333,"correct":32},"耐火极限不低于2．00h的防火隔墙",{"key":30,"text":335,"correct":22},"耐火极限不低于1．00h的不燃性楼板",{"id":337,"libraryId":5,"type":15,"typeLabel":16,"stem":338,"options":339,"answer":27,"analysis":33},932827,"下列关于疏散门设置要求的描述中，正确的是（ ）。",[340,342,344,346],{"key":20,"text":341,"correct":22},"除甲、乙类生产车间和储存仓库外，人数不超过60人且每樘门的平均疏散人数不超过20人的房间，其疏散门的开启方向不限",{"key":24,"text":343,"correct":22},"乙类仓库首层靠墙的外侧可采用推拉门或卷帘门",{"key":27,"text":345,"correct":32},"疏散走道在防火分区处应设置常开甲级防火门",{"key":30,"text":347,"correct":22},"厂房的疏散门的总净宽度应经计算确定，门的最小净宽度不宜小于1．20m",{"id":349,"libraryId":5,"type":15,"typeLabel":16,"stem":350,"options":351,"answer":27,"analysis":33},932828,"步行街是近几年各地流行建设的一种商业模式，根据现行国家工程建设消防技术标准，步行街两侧建筑二层及以上各层商铺的疏散门至该层最近疏散楼梯口或其他安全出口的直线距离不应大于（ ）m。",[352,354,355,357],{"key":20,"text":353,"correct":22},"25",{"key":24,"text":249,"correct":22},{"key":27,"text":356,"correct":32},"37.5",{"key":30,"text":105,"correct":22},{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":24,"analysis":33},932829,"下列关于建筑内可设置1个安全出口或1部疏散楼梯的说法，正确的是（）。",[362,364,366,368],{"key":20,"text":363,"correct":22},"某地上3层印刷厂，每层建筑面积200m2，每层同一时间的作业人数为30人，设1个安全出口",{"key":24,"text":365,"correct":32},"某地上2层建筑，首层为KTV，建筑面积200m2，可容纳40人，该层设1个安全出口",{"key":27,"text":367,"correct":22},"某独立建造的门诊楼，耐火等级为一级，地上3层，每层建筑面积250m2，使用人数20人，设1个安全出口",{"key":30,"text":369,"correct":22},"某单独建造的3层幼儿园，首层建筑面积为150m2，使用人数为35人，设1个安全出口",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":27,"analysis":33},932830,"某二级耐火等级的7层教学楼，层高4m，设有自动喷水灭火系统，教室通过敞开式外廊连接位于楼层两侧疏散楼梯间，其中一部楼梯间紧靠西侧外墙，另一座与东侧外墙有一定距离。该走道东侧尽端的房间门至最近安全出口的直线距离不应大于（）m。",[374,375,377,379],{"key":20,"text":184,"correct":22},{"key":24,"text":376,"correct":22},"20",{"key":27,"text":378,"correct":32},"23.75",{"key":30,"text":353,"correct":22},{"id":381,"libraryId":5,"type":15,"typeLabel":16,"stem":382,"options":383,"answer":30,"analysis":33},932831,"下列厂房的每个楼层至少需要设置 2 个安全出口的是（ ）。",[384,386,388,390],{"key":20,"text":385,"correct":22},"某赛璐珞厂房，耐火等级一级，2 层，高度 8 米，每层建筑面积 98 平方米，每层同一时间的作业人数5 人",{"key":24,"text":387,"correct":22},"某甲酚厂房，耐火等级二级，单层，高度 3.5 米，每层建筑面积 150 平方米，同一时间的作业人数 8人",{"key":27,"text":389,"correct":22},"某服装加工厂房，耐火等级二级，4 层，高度 15.2 米，每层建筑面积 220 平方米，每层同一时间的作业人数 20 人",{"key":30,"text":391,"correct":32},"某石棉加工车间，耐火等级三级，单层，高度 4.3 米，每层建筑面积 500 平方米，同一时间的作业人数 28 人",{"id":393,"libraryId":5,"type":15,"typeLabel":16,"stem":394,"options":395,"answer":20,"analysis":33},932832,"下列关于建筑内疏散楼梯间的做法中，错误的是（ ）。",[396,398,400,402],{"key":20,"text":397,"correct":32},"建筑高度为 30m 的医院，设置有 2 部净宽度均为 1.20m 的防烟楼梯间",{"key":24,"text":399,"correct":22},"建筑高度为 15m 的 3 层公共建筑，总建筑面积为 3000 ㎡，一至三层均为卡拉 OK 厅和舞厅，设置 2 座梯段净宽度均为 2.50m 的封闭疏散楼梯间",{"key":27,"text":401,"correct":22},"某木器加工厂房，建筑高度为 33m，每层作业人数 9 人，设置 2 座净宽度 均为 1.20m 的封闭楼梯间",{"key":30,"text":403,"correct":22},"建筑高度为 21m 的住宅建筑，每个单元的建筑面积为 600 ㎡，户门至楼 梯间的最大水平距离为 11m，每个单元设置一座梯段净宽度为 1.10m 的敞开楼梯间",{"id":405,"libraryId":5,"type":15,"typeLabel":16,"stem":406,"options":407,"answer":20,"analysis":33},932833,"避难走道是指采用防烟设施且两侧设置耐火极限不低于 3.00h 的防火隔墙，用于人员安全通行至室外的走道。下列属于避难走道设置要求的为（ ）。",[408,410,412,414],{"key":20,"text":409,"correct":32},"走道的净宽度不应小于任一防火分区通向走道的设计疏散总净宽度",{"key":24,"text":411,"correct":22},"走道楼板的耐火极限不应小于 1. 00h",{"key":27,"text":413,"correct":22},"走道内部装修材料的燃烧性能应为 B1 级",{"key":30,"text":415,"correct":22},"防火分区至避难走道入口处应设置防烟前室，前室的占地面积不应小于 6.0 m",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":30,"analysis":33},932834,"两个避难层之间的高度不大于（ ）。",[420,422,424,426],{"key":20,"text":421,"correct":22},"25m",{"key":24,"text":423,"correct":22},"30m",{"key":27,"text":425,"correct":22},"45m",{"key":30,"text":51,"correct":32},{"id":428,"libraryId":5,"type":15,"typeLabel":16,"stem":429,"options":430,"answer":27,"analysis":33},932835,"商店营业厅地上第一、二层的人员密度为（ ）。",[431,433,435,437],{"key":20,"text":432,"correct":22},"0．39～0．54",{"key":24,"text":434,"correct":22},"0．30～0．42",{"key":27,"text":436,"correct":32},"0．43～0．60",{"key":30,"text":438,"correct":22},"0．45～0．60",{"id":440,"libraryId":5,"type":15,"typeLabel":16,"stem":441,"options":442,"answer":24,"analysis":33},932836,"对于住宅建筑而言，与防烟楼梯间合用的消防电梯前室的使用面积不应小于（ ）m2。",[443,444,445,446],{"key":20,"text":200,"correct":22},{"key":24,"text":206,"correct":32},{"key":27,"text":178,"correct":22},{"key":30,"text":247,"correct":22},{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":24,"analysis":33},932837,"缓降器是高层建筑的下滑自救器具，由于其操作简单，下滑平稳，是目前市场上应用最广泛的辅助安全疏散产品，其中，自救绳绳长为38m的缓降器适用于（ ）层。",[451,453,455,457],{"key":20,"text":452,"correct":22},"3～5",{"key":24,"text":454,"correct":32},"6～10",{"key":27,"text":456,"correct":22},"11～16",{"key":30,"text":458,"correct":22},"17～20",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":24,"analysis":33},932838,"下列公共建筑中，应采用防烟楼梯间的是（）。",[463,465,467,469],{"key":20,"text":464,"correct":22},"建筑高度为22m的裙房",{"key":24,"text":466,"correct":32},"建筑高度为28m的重要公共建筑",{"key":27,"text":468,"correct":22},"建筑高度为32m的办公建筑",{"key":30,"text":470,"correct":22},"建筑高度为24m的医疗建筑",{"id":472,"libraryId":5,"type":15,"typeLabel":16,"stem":473,"options":474,"answer":24,"analysis":33},932839,"某综合楼耐火等级为一级，地上4层，地下1层，每层建筑面积3000㎡，一层是服装商场，二层为家具商场，三层为录像厅，其疏散走道和辅助用房面积为1000㎡，四层为KTV，其疏散走道和辅助用房面积为900㎡，管理人员100人。该建筑各层疏散宽度最小设计总净宽度，下列正确的是（）。",[475,477,479,481],{"key":20,"text":476,"correct":22},"三层疏散楼梯设置宽度11m",{"key":24,"text":478,"correct":32},"二层疏散楼梯设置宽度20m",{"key":27,"text":480,"correct":22},"一层疏散楼梯设置宽度12.9m",{"key":30,"text":482,"correct":22},"首层疏散走道设置宽度12m",{"id":484,"libraryId":5,"type":15,"typeLabel":16,"stem":485,"options":486,"answer":27,"analysis":33},932840,"根据《建筑设计防火规范》GB50016—2014（2018年版）规定，下列场所中，每个防火分区可设置一个人员安全出口的是（）。",[487,489,491,493],{"key":20,"text":488,"correct":22},"每层建筑面积为90m2的甲类厂房，同一时间的生产人数为7人",{"key":24,"text":490,"correct":22},"设置在单层建筑内的建筑面积为180m2且人数为40人的托儿所",{"key":27,"text":492,"correct":32},"停车数量为40辆的汽车库",{"key":30,"text":494,"correct":22},"建筑面积为200m2的地下仓库",{"id":496,"libraryId":5,"type":497,"typeLabel":498,"stem":499,"options":500,"answer":512,"analysis":33},932841,2,"多选题","某建筑地上16层，首层至三层为商场，四层及以上为住宅，商场部分每层建筑面积为4800m2，住宅部分每层建筑面积为1200m2。该建筑在建造时利用山坡地势条件和屋面层面积优势将三层的屋面层设置为停车场和消防救援操作场地。该建筑室外设计地面标高为-1．2m，首层室内设计地面标高为0．2m，三层屋面板标高为16．6m，顶层为平屋面，其标高为48．8m。下列关于该建筑防火设计的说法中，错误的是（ ）。",[501,503,505,507,509],{"key":20,"text":502,"correct":22},"住宅部分与商场部分之间的楼板应采用耐火极限不低于2．00h的不燃性楼板",{"key":24,"text":504,"correct":22},"住宅部分与商场部分不应共用疏散楼梯和安全出口",{"key":27,"text":506,"correct":22},"住宅部分可采用三层屋面层进行疏散，其疏散楼梯可采用封闭楼梯间",{"key":30,"text":508,"correct":32},"商场部分的疏散楼梯应采用防烟楼梯间",{"key":510,"text":511,"correct":32},"E","该建筑应划分为一类高层公共建筑","DE",{"id":514,"libraryId":5,"type":497,"typeLabel":498,"stem":515,"options":516,"answer":527,"analysis":33},932842,"下列关于建筑内应急照明和疏散指示标志备用电源的连续供电时间说法，正确的有（ ）。",[517,519,521,523,525],{"key":20,"text":518,"correct":32},"某建筑高度为15m的医院，备用电源连续供电时间不应小于60分钟",{"key":24,"text":520,"correct":22},"某综合办公楼建筑高度120m，备用电源连续供电时间不应小于180分钟",{"key":27,"text":522,"correct":32},"建筑高度为85m的综合楼，地上21层，每层建筑面积4800m2，备用电源连续供电时间不应小于60分钟",{"key":30,"text":524,"correct":22},"总建筑面积为110000m2的博物馆，备用电源连续供电时间不应小于90分钟",{"key":510,"text":526,"correct":22},"总建筑面积为19000m2的地下商场，备用电源连续供电时间不应小于60分钟","AC",{"id":529,"libraryId":5,"type":497,"typeLabel":498,"stem":530,"options":531,"answer":542,"analysis":33},932843,"某独立建造的单层商场营业厅，耐火等级为一级，建筑面积3200m2，平均划分为两个防火分区A和 B，由于A防火分区疏散不利，利用通向B防火分区的甲级防火门作为其一个安全出口进行疏散，下列做法不符合规定的有（人员密度取0．6人／m2）（ ）。",[532,534,536,538,540],{"key":20,"text":533,"correct":32},"防火分区A直通室外安全出口的总净宽度为4．1m",{"key":24,"text":535,"correct":22},"防火分区B直通室外安全出口的总净宽度为8．3m",{"key":27,"text":537,"correct":32},"防火分区之间采用防火墙、防火卷帘进行防火分隔",{"key":30,"text":539,"correct":32},"防火分区A直通室外的安全出口的数量为1个",{"key":510,"text":541,"correct":32},"A防火分区利用B防火分区的疏散总宽度为1．9m","ACDE",{"id":544,"libraryId":5,"type":497,"typeLabel":498,"stem":545,"options":546,"answer":557,"analysis":33},932844,"下列关于建筑内消防应急照明和灯光疏散指示标志的备用电源连续供电时间的说法，正确的有（ ）。",[547,549,551,553,555],{"key":20,"text":548,"correct":22},"老年人照料设施不应小于1．5h",{"key":24,"text":550,"correct":22},"建筑高度为90m的公共建筑不应小于3．0h",{"key":27,"text":552,"correct":32},"建筑高度为65m的医院病房楼不应小于1h",{"key":30,"text":554,"correct":22},"建筑高度为18m的教学楼不应小于0．25h",{"key":510,"text":556,"correct":32},"建筑高度为50m的住宅不应小于0．5h","CE",{"id":559,"libraryId":5,"type":497,"typeLabel":498,"stem":560,"options":561,"answer":572,"analysis":33},932845,"在下列哪些情况下，应设置防烟楼梯间（ ）",[562,564,566,568,570],{"key":20,"text":563,"correct":32},"建筑高度大于33m的住宅建筑",{"key":24,"text":565,"correct":32},"一类高层民用建筑及建筑高度大于32m的二类公共高层建筑",{"key":27,"text":567,"correct":22},"高度大于10m的三级耐火等级建筑",{"key":30,"text":569,"correct":32},"建筑高度大于32m且任一层人数超过10人的高层厂房",{"key":510,"text":571,"correct":32},"当地下层数为3层及3层以上，以及地下室内地面与室外出入口地坪高差大于10m时","ABDE",{"id":574,"libraryId":5,"type":497,"typeLabel":498,"stem":575,"options":576,"answer":587,"analysis":33},932846,"符合住宅建筑下列哪些条件时，每个单元每层可以设置1个安全出口（ ）",[577,579,581,583,585],{"key":20,"text":578,"correct":32},"建筑高度不大于27m，每个单元任一层的建筑面积小于650m2且任一套房的户门至安全出口的距离小于15m",{"key":24,"text":580,"correct":32},"建筑高度大于27m且不大于54m，每个单元任一层的建筑面积小于650m2且任一套房的户门至安全出口的距离不大于10m，户门采用乙级防火门，每个单元设置一座通向屋顶的疏散楼梯，单元之间的楼梯通过屋顶连通",{"key":27,"text":582,"correct":22},"建筑高度大于54m的多单元建筑，每个单元任一层的建筑面积小于650m2且任一套房的户门至安全出口的距离不大于10m，户门采用乙级防火门，每个单元设置一座通向屋顶的疏散楼梯，54m以上部分每层相邻单元的疏散楼梯可通过阳台或凹廊连通",{"key":30,"text":584,"correct":22},"对于一、二级耐火等级建筑，当设置不少于2部疏散楼梯且顶层局部升高层数不超过2层、人数之和不超过50人、每层建筑面积不大于200m2时，该局部高出部位可设置一部与下部主体建筑楼梯间直接连通的疏散楼梯，但至少应另设置一个直通主体建筑上人平屋面的安全出口，该上人屋面应符合人员安全疏散要求",{"key":510,"text":586,"correct":22},"建筑中位于两个安全出口之间的房间，当其建筑面积不超过60m2时，可设置一个门，门的净宽不应小于0．9m","AB",{"id":589,"libraryId":5,"type":497,"typeLabel":498,"stem":590,"options":591,"answer":602,"analysis":33},932847,"下列关于建筑安全出口和疏散楼梯的做法，错误的是（ ）。",[592,594,596,598,600],{"key":20,"text":593,"correct":32},"某地下一层建材商店，总建筑面积为2000m2，设置两个净宽度为1．5m的安全出口",{"key":24,"text":595,"correct":32},"某一级耐火等级的四层铝粉厂房，建筑高度为33m，每层建筑面积为3000m2，工作人数为100人，设置两部疏散净宽度为1．5m的封闭楼梯间",{"key":27,"text":597,"correct":22},"某一级耐火等级的商场建筑，地上三层，每层建筑面积为5000m2，建筑高度15m，每层疏散人数为1000人，设置了四部疏散净宽度为2．0m的封闭楼梯间",{"key":30,"text":599,"correct":22},"建筑高度为30m的住宅，户门采用乙级防火门，设置了两部疏散宽度为1．2m的疏散楼梯间",{"key":510,"text":601,"correct":32},"某建筑高度为50m的地上十五层办公楼，每层使用人数为300人，设置了两部疏散净宽度为1．3m的防烟楼梯间","ABE",{"id":604,"libraryId":5,"type":497,"typeLabel":498,"stem":605,"options":606,"answer":617,"analysis":33},932848,"某商业综合楼，耐火等级为一级，地上5层，地下2层，层高为4m，地上部分使用功能为商店、电影院、网吧、托儿所的儿童用房、餐厅等性质，地下为汽车库，部分为设备间，全部设置自动喷水灭火系统。下列关于该建筑内场所安全疏散设施的做法，错误的是（）。",[607,609,611,613,615],{"key":20,"text":608,"correct":32},"位于地上三层的电影院，每个观众厅设置2个疏散门，疏散门总净宽度为2．6m",{"key":24,"text":610,"correct":32},"位于地上四层网吧建筑面积为40m2（可容纳10人）的房间设置1个双向弹簧门",{"key":27,"text":612,"correct":32},"位于地上二层托儿所，位于袋形走道尽端的房间建筑面积50m2，设1个疏散门",{"key":30,"text":614,"correct":22},"地下部分，每个防火分区设有2个封闭楼梯间",{"key":510,"text":616,"correct":32},"位于地上五层的餐厅厅室设有2个疏散门，经过建筑内长度为15m的疏散走道，至楼梯间进行疏散","ABCE",{"id":619,"libraryId":5,"type":497,"typeLabel":498,"stem":620,"options":621,"answer":632,"analysis":33},932849,"下列工业建筑均未设置自动喷水灭火系统，其疏散距离判断不正确的是（）。",[622,624,626,628,630],{"key":20,"text":623,"correct":22},"建筑高度12m耐火二级的3层赤磷厂房内，任一点到安全出口的距离为22m",{"key":24,"text":625,"correct":32},"建筑高度24m耐火二级的6层氧气分离与灌装车间内，任一点到安全出口的距离为55m",{"key":27,"text":627,"correct":22},"建筑高度32m耐火二级的10层粒径为2mm的工业成型硫磺仓库，任一点到安全出口的距离为35m",{"key":30,"text":629,"correct":22},"建筑高度24m耐火二级的6层难燃包装盒加工厂，任一点到安全出口的距离为90m",{"key":510,"text":631,"correct":32},"建筑高度32m耐火二级的10层电动车组装车间的地下部分内，任一点到安全出口的距离为70m","BE",[634,637,640,643,646,649],{"id":15,"name":635,"category":7,"favorite":636},"领导干部任职前廉政法规知识测试题",92,{"id":638,"name":639,"category":7,"favorite":15},595,"建筑结构与设备",{"id":641,"name":642,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":644,"name":645,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":647,"name":648,"category":7,"favorite":8},534,"BIM工程师",{"id":650,"name":648,"category":7,"favorite":8},535]