[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-22":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":590},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,22,50,2960,[13,34,45,56,68,80,92,101,111,123,135,147,157,169,181,193,205,217,229,241,253,265,275,287,299,311,323,335,346,355,365,373,385,397,409,421,433,443,455,467,479,491,503,513,524,536,548,560,569,578],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},932750,1,"单选题","某一级耐火等级的教学楼，建筑高度28m，共7层，教室疏散门外为敞开式外廊，封闭楼梯间位于教学楼两侧，则该教室内任意一点至最近的疏散楼梯间的直线距离不应大于（ ）m。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","15",false,{"key":24,"text":25,"correct":22},"B","30",{"key":27,"text":28,"correct":22},"C","45",{"key":30,"text":31,"correct":32},"D","50",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},932751,"某一级耐火等级的商业综合楼，建筑高度54m，地上5层，地下1层，地上一至三层为商场，四层为游艺场，地下一层为超市，按现行国家工程建设消防技术标准设置了相应消防设施，游艺场位于袋形走道尽端的厅、室疏散门至最近安全出口之间的直线距离不应大于（ ）m。",[38,40,42,44],{"key":20,"text":39,"correct":22},"9",{"key":24,"text":41,"correct":32},"11．25",{"key":27,"text":43,"correct":22},"9．25",{"key":30,"text":21,"correct":22},{"id":46,"libraryId":5,"type":15,"typeLabel":16,"stem":47,"options":48,"answer":24,"analysis":33},932752,"某二级耐火等级的住宅楼，建筑高度36m，设置自动喷水灭火系统，位于袋形走道尽端的户门至最近安全出口的直线距离不应大于（ ）m。",[49,51,53,55],{"key":20,"text":50,"correct":22},"20",{"key":24,"text":52,"correct":32},"25",{"key":27,"text":54,"correct":22},"48",{"key":30,"text":31,"correct":22},{"id":57,"libraryId":5,"type":15,"typeLabel":16,"stem":58,"options":59,"answer":30,"analysis":33},932753,"下列关于疏散楼梯间的说法中，不正确的是（ ）。",[60,62,64,66],{"key":20,"text":61,"correct":22},"楼梯间内不应设置甲、乙、丙类液体管道",{"key":24,"text":63,"correct":22},"烧水间、可燃材料储藏室、垃圾道不应设置在楼梯间内",{"key":27,"text":65,"correct":22},"封闭楼梯间、防烟楼梯间及其前室，不应设置防火卷帘",{"key":30,"text":67,"correct":32},"当住宅的封闭楼梯间确需设置可燃气体管道时，应采用金属管和设置切断气源的阀门",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":20,"analysis":33},932754,"下列建筑中，可以设置1个安全出口或1部疏散楼梯的是（ ）。",[72,74,76,78],{"key":20,"text":73,"correct":32},"单层木结构医疗诊所，建筑面积为150m2，人数为10人",{"key":24,"text":75,"correct":22},"二级耐火等级的网吧，地上2层，每层建筑面积200m2，一层可容纳10人，二层可容纳30人",{"key":27,"text":77,"correct":22},"一级耐火等级的商店，地上3层，每层建筑面积200m2，第二层和第三层人数之和为60人",{"key":30,"text":79,"correct":22},"一级耐火等级的多层建筑，首层为建筑面积190m2的幼儿园",{"id":81,"libraryId":5,"type":15,"typeLabel":16,"stem":82,"options":83,"answer":24,"analysis":33},932755,"下列关于住宅建筑设置1个安全出口的做法，正确的是（ ）。",[84,86,88,90],{"key":20,"text":85,"correct":22},"某建筑高度26m的住宅楼，每层建筑面积700m2，户门采用乙级防火门，任一户门至最近安全出口的距离为10m，设置1部疏散楼梯疏通楼梯可以通过屋面连通相邻",{"key":24,"text":87,"correct":32},"某建筑高度54m的住宅楼，每层建筑面积500m2，户门采用乙级防火门，任一户门至最近安全出口的距离为9m，设置1部疏散楼梯，疏通楼梯可以通过屋面连通相邻单元",{"key":27,"text":89,"correct":22},"某建筑高度32m的住宅楼，每层建筑面积400m2，户门采用甲级防火门，任一户门至最近安全出口的距离为12m，设置1部疏散楼梯，疏散楼梯无法连通屋面",{"key":30,"text":91,"correct":22},"某建筑高度62m的住宅楼，每层建筑面积600m2，户门采用乙级防火门，任一户门至最近安全出口的距离为9m，设置1部疏散楼梯，疏通楼梯可以通过屋面连通相邻单元",{"id":93,"libraryId":5,"type":15,"typeLabel":16,"stem":94,"options":95,"answer":30,"analysis":33},932756,"某独立建造的泡沫塑料工厂的成型车间，地上2层，每层建筑面积200m2，当同时工作人数不超过（ ）人时，可设置1个安全出口。",[96,97,98,100],{"key":20,"text":52,"correct":22},{"key":24,"text":25,"correct":22},{"key":27,"text":99,"correct":22},"40",{"key":30,"text":50,"correct":32},{"id":102,"libraryId":5,"type":15,"typeLabel":16,"stem":103,"options":104,"answer":20,"analysis":33},932757,"某戏剧场观众厅，可容纳观众3000人，则该剧场观众厅的疏散门不应少于（ ）个。",[105,107,109,110],{"key":20,"text":106,"correct":32},"11",{"key":24,"text":108,"correct":22},"13",{"key":27,"text":21,"correct":22},{"key":30,"text":50,"correct":22},{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":30,"analysis":33},932758,"高层丁、戊类厂房，当工作平台上人数满足一定的条件时，其疏散楼梯可采用敞开楼梯或金属梯。当采用金属梯时，其倾斜角度最大为（ ）。",[115,117,119,121],{"key":20,"text":116,"correct":22},"30°",{"key":24,"text":118,"correct":22},"45°",{"key":27,"text":120,"correct":22},"50°",{"key":30,"text":122,"correct":32},"60°",{"id":124,"libraryId":5,"type":15,"typeLabel":16,"stem":125,"options":126,"answer":27,"analysis":33},932759,"下列关于封闭楼梯间的说法，不正确的是（ ）。",[127,129,131,133],{"key":20,"text":128,"correct":22},"除楼梯间的出入口和外窗外，楼梯间的墙上不应开设其他门、窗、洞口",{"key":24,"text":130,"correct":22},"封闭楼梯间自然通风不能满足要求时，应设置机械加压送风系统或采用防烟楼梯间",{"key":27,"text":132,"correct":32},"封闭楼梯间的门必须采用乙级防火门",{"key":30,"text":134,"correct":22},"楼梯间的首层可采用乙级防火门将走道和门厅包括在楼梯间内形成扩大的封闭楼梯间",{"id":136,"libraryId":5,"type":15,"typeLabel":16,"stem":137,"options":138,"answer":24,"analysis":33},932760,"某建筑高度36m的电视机生产厂房，耐火等级为二级，每层建筑面积3000m2，工作人数为160人，下列关于该厂房楼梯间的说法不正确的是（ ）。",[139,141,143,145],{"key":20,"text":140,"correct":22},"楼梯间应采用防烟楼梯间",{"key":24,"text":142,"correct":32},"防烟楼梯间前室与消防电梯前室合用时，建筑面积不应小于10m2",{"key":27,"text":144,"correct":22},"可以采用室外疏散楼梯",{"key":30,"text":146,"correct":22},"厂房疏散走道开向前室的门，前室开向防烟楼梯间的门均应采用乙级防火门",{"id":148,"libraryId":5,"type":15,"typeLabel":16,"stem":149,"options":150,"answer":24,"analysis":33},932761,"住宅单元的疏散楼梯，当分散设置确有困难且任一户门至最近疏散楼梯间入口的距离不大于（ ）m时，可采用剪刀楼梯间。",[151,153,155,156],{"key":20,"text":152,"correct":22},"5",{"key":24,"text":154,"correct":32},"10",{"key":27,"text":21,"correct":22},{"key":30,"text":50,"correct":22},{"id":158,"libraryId":5,"type":15,"typeLabel":16,"stem":159,"options":160,"answer":20,"analysis":33},932762,"下列关于建筑安全出口和疏散楼梯的做法，正确的是（ ）。",[161,163,165,167],{"key":20,"text":162,"correct":32},"高层病房楼每层使用人数为120人，设置2部防烟疏散楼梯，每部楼梯的宽度为1．4m",{"key":24,"text":164,"correct":22},"位于地下一层，总建筑面积为900m2的录像厅，设置4个净宽度均为2m的安全出口",{"key":27,"text":166,"correct":22},"某7层普通办公楼，每层使用人数为750人，设置3部防烟疏散楼梯间，每个楼梯间的净宽度为2．1m",{"key":30,"text":168,"correct":22},"地上2层印刷厂，每层建筑面积1200m2，使用人数不大于240人，设置2部封闭楼梯间，首层设一个疏散外门，宽度为1．2m",{"id":170,"libraryId":5,"type":15,"typeLabel":16,"stem":171,"options":172,"answer":20,"analysis":33},932763,"某建筑高度86m的大楼，使用功能为办公、宾馆、商业和娱乐。一至四层设有餐厅和商场，四层以上为旅馆和办公室，沿疏散走道两侧和尽端布置，地下一层疏散走道尽端设有3个KTV小包间，餐厅的2个疏散门需要通过疏散走道至疏散楼梯间。该建筑按照规范要求设置消防设施。下列建筑内疏散走道的设计中，错误的是（ ）。",[173,175,177,179],{"key":20,"text":174,"correct":32},"室内面积较大的餐厅的疏散门至最近的安全出口的直线走道长度为14m",{"key":24,"text":176,"correct":22},"高层旅馆位于疏散走道尽端疏散门至最近安全出口的疏散距离为16m",{"key":27,"text":178,"correct":22},"KTV疏散走道尽端房间内任一点至最近的安全出口的直线距离为21m",{"key":30,"text":180,"correct":22},"高层办公室袋形疏散走道两端的房间疏散门至最近安全出口的直线距离为21m",{"id":182,"libraryId":5,"type":15,"typeLabel":16,"stem":183,"options":184,"answer":27,"analysis":33},932764,"某二级耐火等级的民用建筑，地上11层，首层为商业服务网点，层高4m，每个分隔单元260m2，二层及以上为住宅，层高3m，每层建筑面积1200m2，“一”字形疏散内走道的东、西端外墙上均设置采光、通风窗，在走道的两端各设置了一座疏散楼梯间，下列关于该建筑的设计，正确的是（ ）。",[185,187,189,191],{"key":20,"text":186,"correct":22},"每个商业服务网点首层设一个安全出口",{"key":24,"text":188,"correct":22},"住宅建筑设置封闭楼梯间",{"key":27,"text":190,"correct":32},"商业服务网点内任意一点到安全出口的疏散的距离为22m",{"key":30,"text":192,"correct":22},"住宅与商业服务网点之间采用耐火极限为2．00h的防火隔墙和耐火极限为1．00h的不燃性楼板分隔",{"id":194,"libraryId":5,"type":15,"typeLabel":16,"stem":195,"options":196,"answer":30,"analysis":33},932765,"某建筑高度为86m的大楼，标准层建筑面积为6000m2，使用功能为办公、商业和娱乐。裙房标准层建筑面积为12000m2，裙房一二层为商店营业厅，三层至四层为餐饮场所，装修材料采用难燃材料，裙房与主体之间采用防火墙分隔，并按现行国家规范要求设有相应的消防设施。下列关于该裙房的说法，不符合规定的是（ ）。",[197,199,201,203],{"key":20,"text":198,"correct":22},"首层商店营业厅应至少划分为3个防火分区",{"key":24,"text":200,"correct":22},"裙房的疏散楼梯间可根据多层建筑确定",{"key":27,"text":202,"correct":22},"餐饮场所在三层应至少划分为3个防火分区",{"key":30,"text":204,"correct":32},"裙房的耐火等级为二级",{"id":206,"libraryId":5,"type":15,"typeLabel":16,"stem":207,"options":208,"answer":27,"analysis":33},932766,"某二级耐火等级的服装加工厂房，地上5层，建筑高度24m，每层建筑面积9000m2，每层使用人数为360人，按照现行国家规定设置相应的消防设施，下列做法不符合规范要求的是（ ）。",[209,211,213,215],{"key":20,"text":210,"correct":22},"采用室外疏散楼梯",{"key":24,"text":212,"correct":22},"厂房内最不利点到最近安全出口的直线距离为58m",{"key":27,"text":214,"correct":32},"每层划分1个防火分区",{"key":30,"text":216,"correct":22},"设置消防电梯，消防电梯的前室使用面积为7m2",{"id":218,"libraryId":5,"type":15,"typeLabel":16,"stem":219,"options":220,"answer":20,"analysis":33},932767,"某一级耐火等级的工业建筑，地上4层，地下1层，层高均为5．5m，每层建筑面积500m2，首层为汽车装配车间，二层为仪表装配车间，三层为车载导航电子装配车间，地下一层为器械装配车间，该建筑按照国家工程建设相关规定设置了消防设施，下列关于该建筑设计的说法中，不符合规定的是（ ）。",[221,223,225,227],{"key":20,"text":222,"correct":32},"该厂房的火灾危险性应划分为丁类",{"key":24,"text":224,"correct":22},"该厂房每层可划分为1个防火分区",{"key":27,"text":226,"correct":22},"地上厂房应设置封闭楼梯间，其防火门应采用乙级防火门",{"key":30,"text":228,"correct":22},"地下一层厂房室内任一点至最近安全出口的直线距离不应大于30m",{"id":230,"libraryId":5,"type":15,"typeLabel":16,"stem":231,"options":232,"answer":24,"analysis":33},932768,"某图书馆，地上5层，地下1层，耐火等级为一级，第5层设计人数均为600人，二至三层设计人数均为700人，首层为借阅大厅，设计人数为250人，所有楼层人员均通过一层进行疏散，则一层直通室外安全出口的最小总净宽度应是（ ）m。",[233,235,237,239],{"key":20,"text":234,"correct":22},"6",{"key":24,"text":236,"correct":32},"7",{"key":27,"text":238,"correct":22},"2．5",{"key":30,"text":240,"correct":22},"3．85",{"id":242,"libraryId":5,"type":15,"typeLabel":16,"stem":243,"options":244,"answer":30,"analysis":33},932769,"下列关于安全出口和疏散门的说法正确的是（ ）。",[245,247,249,251],{"key":20,"text":246,"correct":22},"疏散门应向疏散方向开启，但人数不超过60人的房间且每樘门的平均疏散人数不超过30人时，其疏散门的开启方向不限",{"key":24,"text":248,"correct":22},"某单层白酒液态法酿酒车间，采用卷帘门作为疏散门",{"key":27,"text":250,"correct":22},"高层建筑直通室外的安全出口上方，应设置挑出宽度不小于1．2m的防护挑檐",{"key":30,"text":252,"correct":32},"某单层印刷品仓库，为便于运输，在靠墙的外侧设置卷帘门，同时兼作疏散门",{"id":254,"libraryId":5,"type":15,"typeLabel":16,"stem":255,"options":256,"answer":24,"analysis":33},932770,"下列关于设置一个安全出口或疏散门的说法正确的是（ ）。",[257,259,261,263],{"key":20,"text":258,"correct":22},"某2层幼儿园，首层建筑面积200m2，主要功能为晨检室、办公室，核定人数为25人，在首层设置一个安全出口",{"key":24,"text":260,"correct":32},"某单层占地面积为280m2的仓库设置一个安全出口",{"key":27,"text":262,"correct":22},"某座老年人全日照料中心位于袋形走道尽端的房间，建筑面积为25m2，设置一个疏散门",{"key":30,"text":264,"correct":22},"某办公楼内的一个房间，位于走道尽端，房间内最远点至疏散门的直线距离为12m，建筑面积为200m2，疏散门的净宽度为1．1 m，该房间设置一个疏散门",{"id":266,"libraryId":5,"type":15,"typeLabel":16,"stem":267,"options":268,"answer":24,"analysis":33},932771,"某城市人民大礼堂，属于该市标志性建筑之一，其观众厅设计核定人数为4000人，该观众厅设置的疏散门个数最少为（ ）个。",[269,271,272,273],{"key":20,"text":270,"correct":22},"12",{"key":24,"text":108,"correct":32},{"key":27,"text":106,"correct":22},{"key":30,"text":274,"correct":22},"8",{"id":276,"libraryId":5,"type":15,"typeLabel":16,"stem":277,"options":278,"answer":24,"analysis":33},932772,"下列关于避难走道的说法，错误的是（ ）。",[279,281,283,285],{"key":20,"text":280,"correct":22},"防火分区开向前室的门采用甲级防火门",{"key":24,"text":282,"correct":32},"避难走道的净宽度不应大于任一防火分区通向该避难走道的设计疏散总净宽度",{"key":27,"text":284,"correct":22},"前室开向避难走道的门采用乙级防火门",{"key":30,"text":286,"correct":22},"避难走道直通地面的出口不应少于2个",{"id":288,"libraryId":5,"type":15,"typeLabel":16,"stem":289,"options":290,"answer":27,"analysis":33},932773,"下列关于建筑内楼梯间设置的做法，不符合现行国家消防技术标准的是（ ）。",[291,293,295,297],{"key":20,"text":292,"correct":22},"某商业综合体建筑，裙房与主楼连通部位采用防火卷帘分隔，裙房使用功能为商店和歌舞厅，裙房的疏散楼梯间采用封闭楼梯间",{"key":24,"text":294,"correct":22},"某采用敞开式外廊的4层小学教学楼，每层高3m，其疏散楼梯间采用敞开楼梯间",{"key":27,"text":296,"correct":32},"某老年人照料设施建筑，建筑高度为30m，其疏散楼梯间采用封闭楼梯间",{"key":30,"text":298,"correct":22},"建筑高度为33m的住宅建筑，每户的入户门均采用乙级防火门，其疏散楼梯间采用敞开楼梯间",{"id":300,"libraryId":5,"type":15,"typeLabel":16,"stem":301,"options":302,"answer":30,"analysis":33},932774,"下列关于建筑内疏散楼梯间设置的做法，错误的是（ ）。",[303,305,307,309],{"key":20,"text":304,"correct":22},"某2层服装加工厂，层高5．5m，每层作业人数200人，设置2座净宽1．1m的封闭楼梯间",{"key":24,"text":306,"correct":22},"某一级耐火等级的3层卫生院门诊楼，层高3．3m，每层核定人数150人，采用敞开式外廊，设置2座净宽为1．1m的敞开楼梯间与外廊相连",{"key":27,"text":308,"correct":22},"建筑高度为26m的住宅建筑，该建筑只有一个单元，每层建筑面积为450m2，户门均为乙级防火门，至楼梯间的最大水平距离为3m，设置一座净宽度为1．1m的敞开楼梯间",{"key":30,"text":310,"correct":32},"某KTV，位于地下一层，距室外出入口地坪高差4．5m，建筑面积为600m2，由于无法自然通风和采光，设置了两部净宽度为1．2m的防烟楼梯间",{"id":312,"libraryId":5,"type":15,"typeLabel":16,"stem":313,"options":314,"answer":27,"analysis":33},932775,"下列关于建筑内设置应急照明灯具地面照度的做法中，符合现行消防技术要求的是（ ）。",[315,317,319,321],{"key":20,"text":316,"correct":22},"某二类高层办公楼，其楼梯间设置急照明灯具，地面最低水平照度为3．0lx",{"key":24,"text":318,"correct":22},"某地上四层电影院的观众厅内防烟楼梯间前室设置急照明灯具，地面最低水平照度为3．0lx",{"key":27,"text":320,"correct":32},"某建筑高度22m医院病房楼的楼梯间设置急照明灯具，地面最低水平照度为10．0lx",{"key":30,"text":322,"correct":22},"某地下一层网吧的疏散走道设置应急照明灯具，地面的最低水平照度为5．0lx",{"id":324,"libraryId":5,"type":15,"typeLabel":16,"stem":325,"options":326,"answer":24,"analysis":33},932776,"下列建筑中的消防应急照明备用电源的连续供电时间不符合规范要求的是（ ）。",[327,329,331,333],{"key":20,"text":328,"correct":22},"总建筑面积12000m2的地下超市，消防应急照明备用电源的连续供电时间0．5h",{"key":24,"text":330,"correct":32},"总建筑面积120000m2的市民公共活动中心消防应急照明备用电源的连续供电时间0．5h",{"key":27,"text":332,"correct":22},"建筑高度大于100m的住宅建筑消防应急照明备用电源的连续供电时间1．5h",{"key":30,"text":334,"correct":22},"老年人照料设施的消防应急照明备用电源的连续供电时间1．0h",{"id":336,"libraryId":5,"type":15,"typeLabel":16,"stem":337,"options":338,"answer":24,"analysis":33},932777,"某综合楼办公楼，建筑高度为150m，设有消防应急照明和疏散指示系统等消防设施，则该建筑消防应急照明系统蓄电池连续供电时间不应小于（ ）min。",[339,341,343,345],{"key":20,"text":340,"correct":22},"60",{"key":24,"text":342,"correct":32},"90",{"key":27,"text":344,"correct":22},"180",{"key":30,"text":25,"correct":22},{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":24,"analysis":33},932778,"大型地下商场，总建筑面积为21000m2，则该建筑内消防应急照明备用电源的连续供电时间不应低于（ ）min。",[350,351,352,354],{"key":20,"text":25,"correct":22},{"key":24,"text":340,"correct":32},{"key":27,"text":353,"correct":22},"120",{"key":30,"text":344,"correct":22},{"id":356,"libraryId":5,"type":15,"typeLabel":16,"stem":357,"options":358,"answer":20,"analysis":33},932779,"歌舞娱乐放映游艺场所的疏散出口不应少于两个，当其建筑面积不大于（）m2，经常停留人数不超过15人时可设置一个疏散出口。",[359,360,361,363],{"key":20,"text":31,"correct":32},{"key":24,"text":340,"correct":22},{"key":27,"text":362,"correct":22},"75",{"key":30,"text":364,"correct":22},"80",{"id":366,"libraryId":5,"type":15,"typeLabel":16,"stem":367,"options":368,"answer":24,"analysis":33},932780,"某单层面粉碾磨厂房，耐火等级为一级，建筑面积为140m2，设置一个安全出口，该厂房同一时间的作业人数不应超过（ ）人。",[369,370,371,372],{"key":20,"text":152,"correct":22},{"key":24,"text":154,"correct":32},{"key":27,"text":21,"correct":22},{"key":30,"text":50,"correct":22},{"id":374,"libraryId":5,"type":15,"typeLabel":16,"stem":375,"options":376,"answer":27,"analysis":33},932781,"会议室分中小会议室和大会议室，中小会议室每人使用面积要求：有会议桌的不应小于（ ）m2，无会议桌的不应小于（ ）m2。",[377,379,381,383],{"key":20,"text":378,"correct":22},"1．50，0．50",{"key":24,"text":380,"correct":22},"1．60，0．80",{"key":27,"text":382,"correct":32},"1．80，0．80",{"key":30,"text":384,"correct":22},"1．80，1．00",{"id":386,"libraryId":5,"type":15,"typeLabel":16,"stem":387,"options":388,"answer":20,"analysis":33},932782,"录像厅的疏散人数应根据厅、室的建筑面积按不小于（ ）人／m2计算。",[389,391,393,395],{"key":20,"text":390,"correct":32},"1．0",{"key":24,"text":392,"correct":22},"3．0",{"key":27,"text":394,"correct":22},"4．0",{"key":30,"text":396,"correct":22},"5．0",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":30,"analysis":33},932783,"一、二级耐火等级公共建筑内，当一个防火分区的安全出口全部直通室外确有困难时，防火分区可利用通向相邻防火分区的甲级防火门作为安全出口。下列说法错误的是（ ）。",[401,403,405,407],{"key":20,"text":402,"correct":22},"采用防火墙与相邻防火分区进行分隔",{"key":24,"text":404,"correct":22},"建筑面积大于1000m2的防火分区，直通室外的安全出口数量不应少于2个",{"key":27,"text":406,"correct":22},"建筑面积不大于1000m2的防火分区，直通室外的安全出口数量不应少于1个",{"key":30,"text":408,"correct":32},"该防火分区通向相邻防火分区的疏散净宽度，不应小于计算所需总净宽度的30％",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":30,"analysis":33},932784,"关于厂房疏散宽度的说法，错误的是（ ）。",[413,415,417,419],{"key":20,"text":414,"correct":22},"疏散走道的净宽度不宜小于1．4m",{"key":24,"text":416,"correct":22},"厂房内疏散出口的最小净宽度不宜小于0．9m",{"key":27,"text":418,"correct":22},"疏散楼梯的最小净宽度不宜小于1．1m",{"key":30,"text":420,"correct":32},"首层外门的总净宽度应按该层的疏散人数计算，且该门的最小净宽应不小于1．20m",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":24,"analysis":33},932785,"下列关于避难走道的设置，不符合规范要求的是（ ）。",[425,427,429,431],{"key":20,"text":426,"correct":22},"避难走道楼板的耐火极限不应低于1．50h",{"key":24,"text":428,"correct":32},"避难走道内部装修材料的燃烧性能不应低于B1级",{"key":27,"text":430,"correct":22},"避难走道直通地面的出口不应少于2个，并应设置在不同方向",{"key":30,"text":432,"correct":22},"避难防火分区至避难走道入口处应设置防烟前室，前室的使用面积8．0m2",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":27,"analysis":33},932786,"某单位一栋5层办公楼，总建筑面积为4500m2，采用采用敞开式外廊，楼内设置了送回风道（管）的集中空气调节系统，并按照消防要求设置了自动喷水灭火系统。其位于两个安全出口之间的房间疏散门至最近安全出口的疏散距离不应大于（ ）m。",[437,438,439,441],{"key":20,"text":99,"correct":22},{"key":24,"text":28,"correct":22},{"key":27,"text":440,"correct":32},"55",{"key":30,"text":442,"correct":22},"37.5",{"id":444,"libraryId":5,"type":15,"typeLabel":16,"stem":445,"options":446,"answer":20,"analysis":33},932787,"某乡镇企业利用原有木结构2层楼房改建成手工陶瓷艺品厂房，一层工作人数为75人，二层工作人数为160人。在改造时，需注意首层安全出口的总净宽度不应小于（ ）m。",[447,449,451,453],{"key":20,"text":448,"correct":32},"2.40",{"key":24,"text":450,"correct":22},"1.35",{"key":27,"text":452,"correct":22},"1.40",{"key":30,"text":454,"correct":22},"1.50",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":20,"analysis":33},932788,"下列场所中，设置1个安全出口或1部疏散楼梯说法正确的是（ ）。",[459,461,463,465],{"key":20,"text":460,"correct":32},"某单层砖混结构网吧，建筑面积为200m!，可容纳人数为20人，设置一个安全出口",{"key":24,"text":462,"correct":22},"某耐火等级为二级的地上2层KTV，每层建筑面积均为200m2，每层均可容纳20人，设置一部疏散楼梯",{"key":27,"text":464,"correct":22},"某耐火等级为一级的地上4层办公楼，每层建筑面积200m2，每层使用人数为20人，设置一部疏散楼梯",{"key":30,"text":466,"correct":22},"某耐火等级为一级的多层建筑，首层建筑面积为200m2的幼儿园设置一个安全出口",{"id":468,"libraryId":5,"type":15,"typeLabel":16,"stem":469,"options":470,"answer":27,"analysis":33},932789,"某地上26层、地下3层的商业综合楼，层高4m（室内净空高为3．5m），每层建筑面积为1500m2，首层为大堂，二层至五层为商场，其中四层设有录像厅，地上六层及以上为办公区，每层划分为一个防火分区。下列关于该录像厅的防火设计中，不符合规范要求的是（）。",[471,473,475,477],{"key":20,"text":472,"correct":22},"采用耐火极限为2．00h的防火隔墙划分多个建筑面积为40m2—120m2不等的厅、室",{"key":24,"text":474,"correct":22},"建筑面积为50m2的厅、室（可容纳10人）设置1个向疏散方向开启的疏散门",{"key":27,"text":476,"correct":32},"与商场之间采用耐火极限为2．00h的防火隔墙和1．50h的不燃性楼板分隔，隔墙上的门采用乙级防火门",{"key":30,"text":478,"correct":22},"录像厅所在楼层划分3个防烟分区，设置一套独立的机械排烟系统",{"id":480,"libraryId":5,"type":15,"typeLabel":16,"stem":481,"options":482,"answer":27,"analysis":33},932790,"下列场所可不设置防烟设施的是（）。",[483,485,487,489],{"key":20,"text":484,"correct":22},"防烟楼梯间",{"key":24,"text":486,"correct":22},"避难层",{"key":27,"text":488,"correct":32},"疏散走道",{"key":30,"text":490,"correct":22},"消防电梯前室",{"id":492,"libraryId":5,"type":15,"typeLabel":16,"stem":493,"options":494,"answer":24,"analysis":33},932791,"体育馆观众厅座位的布置，纵走道之间每排座位不宜超过（ ）个，横走道之间的排数不宜超过（ ）排。",[495,497,499,501],{"key":20,"text":496,"correct":22},"20,22",{"key":24,"text":498,"correct":32},"26,20",{"key":27,"text":500,"correct":22},"22,22",{"key":30,"text":502,"correct":22},"20,20",{"id":504,"libraryId":5,"type":15,"typeLabel":16,"stem":505,"options":506,"answer":20,"analysis":33},932792,"某设置商业服务网点的住宅建筑,二级耐火等级,其商业服务网点每个分隔单元内设置有自动喷水灭火系统,服务网点单元内的疏散距离不大于（ ）m。",[507,509,510,512],{"key":20,"text":508,"correct":32},"27.5",{"key":24,"text":52,"correct":22},{"key":27,"text":511,"correct":22},"22",{"key":30,"text":50,"correct":22},{"id":514,"libraryId":5,"type":15,"typeLabel":16,"stem":515,"options":516,"answer":27,"analysis":33},932793,"某二级耐火等级的多层公共建筑的首层设置了两个防火分区，分别为防火分区一和防火分区二，两个防火分区之间用防火墙分隔，防火分区二有两个直通室外的安全出口。由于条件所限，防火分区一只设置了一个直通室外的安全出口，为符合规范要求，在两个防火分区之间的防火墙上开设了一个甲级防火门可供防火分区一内的人员进行疏散。经计算得知，防火分区一内人员疏散所需的最小总净宽度是 3m，防火分区二内人员疏散所需的最小总净宽度是 4m，则防火分区二直通室外的两个安全出口的总净宽度不应小于（ ）m",[517,519,520,522],{"key":20,"text":518,"correct":22},"4",{"key":24,"text":236,"correct":22},{"key":27,"text":521,"correct":32},"4.9",{"key":30,"text":523,"correct":22},"6.1",{"id":525,"libraryId":5,"type":15,"typeLabel":16,"stem":526,"options":527,"answer":24,"analysis":33},932794,"公共建筑内安全出口和疏散门的净宽度不应小于（ ），疏散走道和疏散楼梯的净宽度不应小于（ ）。",[528,530,532,534],{"key":20,"text":529,"correct":22},"0．90m，1．00m",{"key":24,"text":531,"correct":32},"0．90m，1．10m",{"key":27,"text":533,"correct":22},"1．00m，0．90m",{"key":30,"text":535,"correct":22},"1．10m，0．90m",{"id":537,"libraryId":5,"type":15,"typeLabel":16,"stem":538,"options":539,"answer":30,"analysis":33},932795,"下列关于疏散楼梯间的说法正确的是（ ）。",[540,542,544,546],{"key":20,"text":541,"correct":22},"封闭楼梯间内可以设置卷帘",{"key":24,"text":543,"correct":22},"公共建筑的楼梯间内可以敷设或穿越可燃气体管道",{"key":27,"text":545,"correct":22},"建筑中的疏散楼梯间在各层的平面位置可以改变",{"key":30,"text":547,"correct":32},"疏散用楼梯和疏散通道上的阶梯不宜采用螺旋楼梯和扇形踏步",{"id":549,"libraryId":5,"type":15,"typeLabel":16,"stem":550,"options":551,"answer":27,"analysis":33},932796,"下列关于办公建筑疏散走道设置基本要求说法正确的是（ ）。",[552,554,556,558],{"key":20,"text":553,"correct":22},"走道中的门应向室内方向开启",{"key":24,"text":555,"correct":22},"疏散走道在防火分区处应设置常开乙级防火门",{"key":27,"text":557,"correct":32},"尽量避免设置袋形走道",{"key":30,"text":559,"correct":22},"走道长度小于40m且单面布房，走道净宽设置为1．0m",{"id":561,"libraryId":5,"type":15,"typeLabel":16,"stem":562,"options":563,"answer":20,"analysis":33},932797,"一个容纳人数为2800人的剧院，其需要设置的疏散门个数至少为（ ）。",[564,565,566,567],{"key":20,"text":154,"correct":32},{"key":24,"text":270,"correct":22},{"key":27,"text":108,"correct":22},{"key":30,"text":568,"correct":22},"14",{"id":570,"libraryId":5,"type":15,"typeLabel":16,"stem":571,"options":572,"answer":24,"analysis":33},932798,"布置疏散走道时，剧院、电影院、礼堂等纵走道之间的座位数，每排不宜超过（ ）个。",[573,574,575,577],{"key":20,"text":50,"correct":22},{"key":24,"text":511,"correct":32},{"key":27,"text":576,"correct":22},"26",{"key":30,"text":25,"correct":22},{"id":579,"libraryId":5,"type":15,"typeLabel":16,"stem":580,"options":581,"answer":30,"analysis":33},932799,"封闭楼梯间的适用范围不包括（ ）。",[582,584,586,588],{"key":20,"text":583,"correct":22},"医疗建筑",{"key":24,"text":585,"correct":22},"旅馆",{"key":27,"text":587,"correct":22},"图书馆",{"key":30,"text":589,"correct":32},"一类高层建筑",[591,594,597,600,603,606],{"id":15,"name":592,"category":7,"favorite":593},"领导干部任职前廉政法规知识测试题",92,{"id":595,"name":596,"category":7,"favorite":15},595,"建筑结构与设备",{"id":598,"name":599,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":601,"name":602,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":604,"name":605,"category":7,"favorite":8},534,"BIM工程师",{"id":607,"name":605,"category":7,"favorite":8},535]