[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-21":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":646},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,21,50,2960,[13,34,46,58,70,80,92,104,114,126,138,150,159,171,182,190,202,214,226,244,259,274,289,304,318,333,348,363,377,392,407,421,435,449,463,477,492,506,520,532,544,556,567,576,585,596,607,617,625,635],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},932700,1,"单选题","某市工业区新建一座铝粉加工厂房，地上7层，建筑高度为32m，该厂房的耐火等级不应低于（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","一级",true,{"key":24,"text":25,"correct":26},"B","二级",false,{"key":28,"text":29,"correct":26},"C","三级",{"key":31,"text":32,"correct":26},"D","四级","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},932701,"某建筑地上8层，首层设有多个面积为200-500m2的营业性用房，其余楼层为住宅。该建筑室外设计地面的标高为0．2m，首层室内设计地面标高为1．2m，平屋面的标高为24．1m，该建筑采用二级耐火等级，商店营业厅与住宅之间楼板的耐火极限不应低于（ ）h。",[38,40,42,44],{"key":20,"text":39,"correct":26},"1．0",{"key":24,"text":41,"correct":22},"1．5",{"key":28,"text":43,"correct":26},"2．0",{"key":31,"text":45,"correct":26},"2．5",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":28,"analysis":33},932702,"某二级耐火等级的多层饲料加工厂房，其中一个防火分区内未设置自动灭火系统的面积为500m2，该防火分区设置自动灭火系统区域的建筑面积（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":26},"最大允许为3500m2",{"key":24,"text":53,"correct":26},"最大允许为4000m2",{"key":28,"text":55,"correct":22},"最大允许为7000m2",{"key":31,"text":57,"correct":26},"不限",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":28,"analysis":33},932703,"某一级耐火等级商业综合楼，建筑高度为58m，每层建筑面积12000m2，一至三层为商场，采用不燃材料装修，四层及以上为办公楼，综合楼设置有相应的消防设施，则该商场每层至少应划分（ ）个防火分区。",[62,64,66,68],{"key":20,"text":63,"correct":26},"1",{"key":24,"text":65,"correct":26},"2",{"key":28,"text":67,"correct":22},"3",{"key":31,"text":69,"correct":26},"4",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},932704,"防火墙横截面中心线水平距离天窗端面小于（ ）m，且天窗端面为可燃性墙体时，应采取防止火势蔓延的措施。",[74,75,76,78],{"key":20,"text":65,"correct":26},{"key":24,"text":69,"correct":22},{"key":28,"text":77,"correct":26},"6",{"key":31,"text":79,"correct":26},"8",{"id":81,"libraryId":5,"type":15,"typeLabel":16,"stem":82,"options":83,"answer":24,"analysis":33},932705,"某耐火等级为一级的单层乙类厂房，层高6m，防火分区采用防火墙沿厂房南北方向分隔（长度为21m），当采用防火卷帘代替部分防火墙时，防火卷帘最多可以设置（ ）m。",[84,86,88,90],{"key":20,"text":85,"correct":26},"7",{"key":24,"text":87,"correct":22},"10",{"key":28,"text":89,"correct":26},"12",{"key":31,"text":91,"correct":26},"20",{"id":93,"libraryId":5,"type":15,"typeLabel":16,"stem":94,"options":95,"answer":31,"analysis":33},932706,"某公共建筑，每层净空高度为6m，按规范要求设置机械排烟系统，该建筑内用来划分防烟分区的挡烟垂壁的高度不应小于（ ）mm。",[96,98,100,102],{"key":20,"text":97,"correct":26},"300",{"key":24,"text":99,"correct":26},"400",{"key":28,"text":101,"correct":26},"500",{"key":31,"text":103,"correct":22},"600",{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":28,"analysis":33},932707,"某高层综合楼地下部分设有物业服务用房，建筑面积为900m2，划分为一个防火分区时，设置自动喷水灭火系统区域的面积至少为（ ）m2。",[108,109,110,112],{"key":20,"text":101,"correct":26},{"key":24,"text":99,"correct":26},{"key":28,"text":111,"correct":22},"800",{"key":31,"text":113,"correct":26},"900",{"id":115,"libraryId":5,"type":15,"typeLabel":16,"stem":116,"options":117,"answer":31,"analysis":33},932708,"下列建筑的防火分区允许采用防火卷帘或防火分隔水幕进行分隔的是（ ）。",[118,120,122,124],{"key":20,"text":119,"correct":26},"二级耐火等级植物油加工厂的浸出车间",{"key":24,"text":121,"correct":26},"二级耐火等级酒精度为48℃的白酒灌装车间",{"key":28,"text":123,"correct":26},"二级耐火等级某氯酸钾制备车间，建筑面积3000m2",{"key":31,"text":125,"correct":22},"建筑面积为6000m2的高锰酸钾制备厂房",{"id":127,"libraryId":5,"type":15,"typeLabel":16,"stem":128,"options":129,"answer":24,"analysis":33},932709,"某金融建筑，建筑高度60m，建筑内设有自动喷水灭火系统，则一个防火分区的最大允许建筑面积为（ ）m2。",[130,132,134,136],{"key":20,"text":131,"correct":26},"1500",{"key":24,"text":133,"correct":22},"3000",{"key":28,"text":135,"correct":26},"5000",{"key":31,"text":137,"correct":26},"2500",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":31,"analysis":33},932710,"某住宅与其他使用功能组合的建筑，所采取的以下防火分隔措施中不合理的是（ ）。",[142,144,146,148],{"key":20,"text":143,"correct":26},"住宅部分与非住宅部分相接处上、下层开口之间设置高度1．3m的实体墙",{"key":24,"text":145,"correct":26},"住宅部分与非住宅部分相接处上、下层开口之间设置挑出宽度1．0m、长度大于开口宽度的防火挑檐",{"key":28,"text":147,"correct":26},"建筑内设置了自动喷水灭火系统，住宅部分与非住宅部分相接处上、下层开口之间设置1．0m的实体墙",{"key":31,"text":149,"correct":22},"住宅部分相邻户开口之间的墙体宽度为0．8m，在开口之间设置凸出外墙0．5m的隔板",{"id":151,"libraryId":5,"type":15,"typeLabel":16,"stem":152,"options":153,"answer":28,"analysis":33},932711,"某二级耐火等级高层乙类厂房，4层，每层建筑面积3900m2，室内净空高度6．5m。该厂房至少应设（ ）个防烟分区。",[154,155,157,158],{"key":20,"text":77,"correct":26},{"key":24,"text":156,"correct":26},"16",{"key":28,"text":79,"correct":22},{"key":31,"text":69,"correct":26},{"id":160,"libraryId":5,"type":15,"typeLabel":16,"stem":161,"options":162,"answer":31,"analysis":33},932712,"高层建筑内的多功能厅设在四层及以上楼层时，应符合现行国家工程建设消防技术标准，下列说法中不正确的是（ ）。",[163,165,167,169],{"key":20,"text":164,"correct":26},"应设置自动喷水灭火系统",{"key":24,"text":166,"correct":26},"一个厅、室的疏散门不应少于两个",{"key":28,"text":168,"correct":26},"应设置火灾自动报警系统",{"key":31,"text":170,"correct":22},"一个厅、室的使用面积不宜超过500m2",{"id":172,"libraryId":5,"type":15,"typeLabel":16,"stem":173,"options":174,"answer":31,"analysis":33},932713,"某二级耐火等级的面粉加工厂碾磨车间，地上5层，层高4m，每层局部设置自动喷水灭火系统时可以划分为一个防火分区，其中每层未设置自动喷水灭火系统的建筑面积为1000m2，则每层设置自动喷水灭火系统的建筑面积最大允许为（ ）m2。",[175,177,179,180],{"key":20,"text":176,"correct":26},"1000",{"key":24,"text":178,"correct":26},"2000",{"key":28,"text":133,"correct":26},{"key":31,"text":181,"correct":22},"4000",{"id":183,"libraryId":5,"type":15,"typeLabel":16,"stem":184,"options":185,"answer":24,"analysis":33},932714,"某综合楼，地上6层，层高5m，每层建筑面积为6000m2，首层至二层为商店营业厅，二层以上为办公，建筑的内部装修均采用不燃或难燃材料，并设置了湿式自动喷水灭火系统和火灾自动报警系统保护，则该建筑首层至少设置（）个水流指示器。",[186,187,188,189],{"key":20,"text":63,"correct":26},{"key":24,"text":65,"correct":22},{"key":28,"text":67,"correct":26},{"key":31,"text":69,"correct":26},{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":31,"analysis":33},932715,"中庭与周围相连通的空间进行防火分隔时，下列设置不正确的是（ ）。",[194,196,198,200],{"key":20,"text":195,"correct":26},"采用防火隔墙时，其耐火极限不应低于1.00h；",{"key":24,"text":197,"correct":26},"采用防火玻璃墙时，其耐火隔热性和耐火完整性不应低于 1.00h，采用耐火完整性不低于 1.00h 的非隔热性防火玻璃墙时，应设置自动喷水灭火系统保护；",{"key":28,"text":199,"correct":26},"采用防火卷帘时，其耐火极限不应低于 3.00h，并应符合卷帘分隔的相关规定；",{"key":31,"text":201,"correct":22},"与中庭相连通的门、窗，应采用甲级防火门、窗。",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":20,"analysis":33},932716,"某多层办公楼，采用玻璃幕墙，其耐火完整性不应低于（ ）h。",[206,208,210,212],{"key":20,"text":207,"correct":22},"0.5",{"key":24,"text":209,"correct":26},"1.0",{"key":28,"text":211,"correct":26},"1.5",{"key":31,"text":213,"correct":26},"3.0",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":20,"analysis":33},932717,"当锅炉房必须在防火墙上开门时，应设置（ ）防火门。",[218,220,222,224],{"key":20,"text":219,"correct":22},"甲级",{"key":24,"text":221,"correct":26},"乙级",{"key":28,"text":223,"correct":26},"丙级",{"key":31,"text":225,"correct":26},"丁级",{"id":227,"libraryId":5,"type":228,"typeLabel":229,"stem":230,"options":231,"answer":243,"analysis":33},932718,2,"多选题","下列关于建筑防火分隔的做法，不正确的有（ ）。",[232,234,236,238,240],{"key":20,"text":233,"correct":26},"某网吧厅、室之间采用耐火极限为2．50h的防火隔墙和1．50h的不燃性楼楼板进行分隔",{"key":24,"text":235,"correct":22},"某柴油发电机房采用耐火极限为2．00h的防火隔墙和1．50h的不燃性楼板与储油间进行分隔",{"key":28,"text":237,"correct":22},"某变压器室采用耐火极限为2．00h的防火隔墙和1．00h的不燃性楼板与其他部位进行分隔",{"key":31,"text":239,"correct":22},"某常压燃油锅炉房采用耐火极限为2．50h的防火隔墙和1．50h的不燃性楼板与储油间分隔",{"key":241,"text":242,"correct":26},"E","某住宅建筑与非住宅之间采用耐火极限为3．00h的防火隔墙和1．50h的不燃性楼板分隔","BCD",{"id":245,"libraryId":5,"type":228,"typeLabel":229,"stem":246,"options":247,"answer":258,"analysis":33},932719,"防火分区是指采用具有较高耐火极限的墙和楼板等构件分隔而成的区域，能在一定时间内阻止火势向同一建筑的其他区域蔓延的防火单元，下列不属于厂房防火分区主要划分因素的有（ ）。",[248,250,252,254,256],{"key":20,"text":249,"correct":26},"生产的火灾危险性类别",{"key":24,"text":251,"correct":26},"厂房的层数",{"key":28,"text":253,"correct":22},"厂房的建筑面积",{"key":31,"text":255,"correct":22},"厂房设置消火栓系统的情况",{"key":241,"text":257,"correct":26},"厂房的耐火等级","CD",{"id":260,"libraryId":5,"type":228,"typeLabel":229,"stem":261,"options":262,"answer":273,"analysis":33},932720,"下列关于防火分区划分正确的是（ ）。",[263,265,267,269,271],{"key":20,"text":264,"correct":22},"厂房内设置自动灭火系统时，每个防火分区的最大允许建筑面积可按规定增加1．0倍",{"key":24,"text":266,"correct":22},"储存丙类1项火灾危险性类别物品的地下仓库，仓库耐火等级为二级时，其防火分区的建筑面积为150m2",{"key":28,"text":268,"correct":26},"某位于地下设置自动灭火系统和火灾自动报警系统并采用不燃或难燃装修材料的二级耐火等级的营业厅单个防火分区允许的最大建筑面积为2000m2",{"key":31,"text":270,"correct":26},"隧道内附设的地下设备用房每个防火分区最大的允许建筑面积不应大于2000m2",{"key":241,"text":272,"correct":26},"采用木结构建筑的机动车车库建筑面积不应大于100m2","AB",{"id":275,"libraryId":5,"type":228,"typeLabel":229,"stem":276,"options":277,"answer":288,"analysis":33},932721,"下列关于防火墙的构造要求说法不正确的是（ ）。",[278,280,282,284,286],{"key":20,"text":279,"correct":26},"防火墙横截面中心线水平距离天窗端面小于4m，且天窗端面为可燃性墙体时，应采取防止火势蔓延的设施",{"key":24,"text":281,"correct":22},"防火墙内可以设置排气道",{"key":28,"text":283,"correct":26},"建筑物内的防火墙不宜设在转角处",{"key":31,"text":285,"correct":26},"防火墙应直接设置在基础上或钢筋混凝土框架上",{"key":241,"text":287,"correct":22},"建筑物外墙如为难燃性墙体时，防火墙应凸出墙的外表面30cm","BE",{"id":290,"libraryId":5,"type":228,"typeLabel":229,"stem":291,"options":292,"answer":303,"analysis":33},932722,"下列关于建筑中疏散门设置的做法，正确的有（ ）。",[293,295,297,299,301],{"key":20,"text":294,"correct":22},"建筑面积为900m2的2层重油仓库，在首层靠墙的外侧使用2个卷帘门作为疏散门",{"key":24,"text":296,"correct":26},"剧场首层大厅490m2，在东西两侧设置2个净宽2．0m的玻璃转门作为疏散门",{"key":28,"text":298,"correct":26},"建筑面积为90m2的办公室，核定人数为50人，设置一个净宽为1．5m向内开启的平开门",{"key":31,"text":300,"correct":26},"建筑面积250m2的单层氨压缩机房，设置2个净宽为1．6m的推拉门",{"key":241,"text":302,"correct":22},"地上6层建筑高度为24m的办公楼，采用封闭楼梯间，楼梯间采用双向弹簧门","AE",{"id":305,"libraryId":5,"type":228,"typeLabel":229,"stem":306,"options":307,"answer":288,"analysis":33},932723,"下列厂房的安全出口可以仅设置1个的有（ ）。",[308,310,312,314,316],{"key":20,"text":309,"correct":26},"某单层白兰地蒸馏车间，建筑面积为120m2，且同一时间的作业人数为5人",{"key":24,"text":311,"correct":22},"某地上3层煤粉厂房，每层建筑面积为130m2，且同一时间的作业人数为10人",{"key":28,"text":313,"correct":26},"某多层石棉加工车间，每层建筑面积350m2，且同一时间的作业人数为45人",{"key":31,"text":315,"correct":26},"某多层饲料加工厂，每层建筑面积260m2，且同一时间的作业人数为20人",{"key":241,"text":317,"correct":22},"某地下电子仪表维修厂房，每层建筑面积为50m2，且同一时间作业人数为15人",{"id":319,"libraryId":5,"type":228,"typeLabel":229,"stem":320,"options":321,"answer":332,"analysis":33},932724,"下列民用建筑内房间不可以仅设一个疏散门的有（ ）。",[322,324,326,328,330],{"key":20,"text":323,"correct":26},"某单独建造的一级耐火等级的幼儿园，地上3层，位于袋形走道两侧，建筑面积为50m2的房间",{"key":24,"text":325,"correct":26},"某位于两个安全出口之间的医院病房，建筑面积为60m2",{"key":28,"text":327,"correct":22},"某位于袋形走道尽端的教室，建筑面积为140m2，疏散门净宽度为1．3m，教室内任一点至最近的疏散门之间的直线距离为12m",{"key":31,"text":329,"correct":22},"某附设在一级耐火等级建筑内的托儿所，位于袋形走道尽端，建筑面积45m2，疏散门宽度为1．6m，疏散门至最近安全出口的直线距离为10m",{"key":241,"text":331,"correct":22},"某医院门诊楼房间，位于两个安全出口之间，建筑面积为150m2","CDE",{"id":334,"libraryId":5,"type":228,"typeLabel":229,"stem":335,"options":336,"answer":347,"analysis":33},932725,"下列关于避难走道的说法，不正确的有（ ）。",[337,339,341,343,345],{"key":20,"text":338,"correct":22},"防火分区至避难走道入口处应设置防烟前室，前室的建筑面积不应小于6．0m2",{"key":24,"text":340,"correct":22},"避难走道防火隔墙的耐火极限不应低于3．00h，楼板的耐火极限不应低于2．0h",{"key":28,"text":342,"correct":26},"避难走道直通地面的出口不应少于2个，并应设置在不同方向",{"key":31,"text":344,"correct":22},"开向前室的门应采用乙级防火门，前室开向避难走道的门应采用甲级防火门",{"key":241,"text":346,"correct":22},"任一防火分区通向避难走道的门至该避难走道最近直通地面的出口的距离不应小于60m","ABDE",{"id":349,"libraryId":5,"type":228,"typeLabel":229,"stem":350,"options":351,"answer":362,"analysis":33},932726,"下列建筑中，不需要设置防烟楼梯间的有（ ）。",[352,354,356,358,360],{"key":20,"text":353,"correct":22},"建筑高度32m的旅馆",{"key":24,"text":355,"correct":26},"建筑高度32m的医院病房楼",{"key":28,"text":357,"correct":22},"地上部分设置防烟楼梯间的地下建筑",{"key":31,"text":359,"correct":22},"建筑高度33m的住宅",{"key":241,"text":361,"correct":22},"建筑高度33m的丙类厂房","ACDE",{"id":364,"libraryId":5,"type":228,"typeLabel":229,"stem":365,"options":366,"answer":258,"analysis":33},932727,"下列关于室外疏散楼梯的说法，不正确的有（ ）。",[367,369,371,373,375],{"key":20,"text":368,"correct":26},"室外疏散楼梯倾斜角度不应大于45°",{"key":24,"text":370,"correct":26},"室外疏散楼梯栏杆扶手的高度不应小于1．10m，楼梯的净宽度不应小于0．90m",{"key":28,"text":372,"correct":22},"梯段和平台均应采用不燃材料制作，平台的耐火极限不应低于0．25h，梯段的耐火极限不应低于0．5h",{"key":31,"text":374,"correct":22},"通向室外楼梯的门应采用乙级防火门，并应向外开启，正对梯段",{"key":241,"text":376,"correct":26},"除疏散门外，楼梯周围2m内的墙面上不应设置门、窗、洞口",{"id":378,"libraryId":5,"type":228,"typeLabel":229,"stem":379,"options":380,"answer":391,"analysis":33},932728,"某建筑高度为160m的办公建筑，首层室内地面标高为±0．000m，消防车登高操作场地的地面标高为-0．200m，首层层高8．0m，地上其余楼层的层高均为4．9m。下列关于该建筑避难层的做法中，错误的有（ ）。",[381,383,385,387,389],{"key":20,"text":382,"correct":22},"将第一个避难层设置在第十一层",{"key":24,"text":384,"correct":22},"采用耐火极限为1．5h的不燃性楼板",{"key":28,"text":386,"correct":26},"第二个避难层与第一个避难层相距10层设置",{"key":31,"text":388,"correct":26},"第二个避难层的避难净面积按0．2m2／人计算确定",{"key":241,"text":390,"correct":22},"避难层设有独立的排烟设施，外窗采用甲级防火窗","ABE",{"id":393,"libraryId":5,"type":228,"typeLabel":229,"stem":394,"options":395,"answer":406,"analysis":33},932729,"下列关于建筑内消防应急照明灯具照度的说法中，正确的有（ ）。",[396,398,400,402,404],{"key":20,"text":397,"correct":26},"商场疏散走道的地面最低水平照度不应低于1．0lx",{"key":24,"text":399,"correct":22},"避难走道地面最低水平照度不应低于5．0lx",{"key":28,"text":401,"correct":26},"避难层（间）的地面最低水平照度不应低于5．0lx",{"key":31,"text":403,"correct":22},"手术部的避难间地面最低水平照度不应低于10．0lx",{"key":241,"text":405,"correct":22},"普通办公楼楼梯间的地面最低水平照度不应低于5．0lx","BDE",{"id":408,"libraryId":5,"type":228,"typeLabel":229,"stem":409,"options":410,"answer":406,"analysis":33},932730,"某医院病房楼，地上8层，层高4m，每层建筑面积1200m2，每层设置30个病房，每间病房最多容纳4人。病房在“一”字形疏散内走道双面布置，疏散楼梯间位于建筑两端，按照现行国家规定设置了相应的消防设施，下列关于该病房楼安全疏散设施的说法，正确的是（）。",[411,413,415,417,419],{"key":20,"text":412,"correct":26},"病房楼应设置封闭楼梯间，楼梯间的门应为乙级防火门",{"key":24,"text":414,"correct":22},"病房内最远点距最近楼梯间的直线距离不应大于45m",{"key":28,"text":416,"correct":26},"病房楼每层至少设2部净宽度为1．2m的疏散楼梯",{"key":31,"text":418,"correct":22},"病房楼内疏散走道宽度不应低于1．5m",{"key":241,"text":420,"correct":22},"首层至少设置2个净宽度为1．3m的疏散门",{"id":422,"libraryId":5,"type":228,"typeLabel":229,"stem":423,"options":424,"answer":347,"analysis":33},932731,"以下对高层病房楼设置避难间的规定，说法错误的是（ ）。",[425,427,429,431,433],{"key":20,"text":426,"correct":22},"避难间服务的护理单元不应超过 2 个，其建筑面积应按每个护理单元不小于 25m2确定",{"key":24,"text":428,"correct":22},"避难间应采用耐火极限不低于 2.5h 的防火隔墙和甲级防火门与其他部位分隔",{"key":28,"text":430,"correct":26},"避难间应设置消防专线电话和消防应急广播",{"key":31,"text":432,"correct":22},"避难间的出口处应设置明显的指示标志",{"key":241,"text":434,"correct":22},"避难间应设置直接对外的可开启窗口或独立的机械防烟设施，外窗应采用甲级防火窗",{"id":436,"libraryId":5,"type":228,"typeLabel":229,"stem":437,"options":438,"answer":303,"analysis":33},932732,"某综合楼地上 21 层，地下 3 层，建筑高度为 68m ，采用钢筋混凝土结构，耐火等级为一级，其中1-4 层为商业卖场，5 层为 KTV 、酒吧，6 层为电影院， 7-12 层为大型企业的集中办公区， 12-21 层为公寓式写字楼，该建筑按照相关规范要求设置了相应的消防设施。下列关于该建筑安全疏散说法正确的是（ ）。",[439,441,443,445,447],{"key":20,"text":440,"correct":22},"位于该建筑 3 层的某服装卖场的营业厅（设有2个安全出口）其室内任一点室最近安全出口的距离为 50m",{"key":24,"text":442,"correct":26},"该建筑 5 层的酒吧位于袋行走道尽端，该酒吧面积为 60 ㎡设置一个疏散门，该疏散门至防烟楼梯间的距离为 10m",{"key":28,"text":444,"correct":26},"位于 6 层的电影院通过该建筑的 4 部防烟楼梯间进行疏散，电影院的任一疏散门至安全出口的距离均满足规范要求",{"key":31,"text":446,"correct":26},"18 层位于疏散走道尽端的办公室建筑面积为 120 ㎡设置一个疏散门，该疏散门至最近的疏散楼梯的疏散距离为 25m",{"key":241,"text":448,"correct":22},"位于 8 层的集中办公区采用开敞式办公（设有2个安全出口），该办公区位于两个疏散楼梯间之间，办公区内任一点至最近安全出口的疏散距离为 47m",{"id":450,"libraryId":5,"type":228,"typeLabel":229,"stem":451,"options":452,"answer":462,"analysis":33},932733,"下列关于人防工程中的避难走道的设置要求，说法错误的是（ ）。",[453,454,456,458,460],{"key":20,"text":342,"correct":26},{"key":24,"text":455,"correct":22},"避难走道的装修材料燃烧性能等级应为B1级",{"key":28,"text":457,"correct":22},"防火分区至避难走道入口处应设置前室，前室使用面积不应小于5m2",{"key":31,"text":459,"correct":26},"避难走道应设置消火栓、火灾应急照明、应急广播和消防专线电话",{"key":241,"text":461,"correct":26},"通向避难走道的各防火分区人数不等时，避难走道的净宽不应小于设计容纳人数最多一个防火分区通向避难走道各安全出口最小净宽之和","BC",{"id":464,"libraryId":5,"type":228,"typeLabel":229,"stem":465,"options":466,"answer":347,"analysis":33},932734,"建筑高度大于100m的公共建筑，应设置避难层（间）。下列关于避难层（间）设置的说法中正确的是（ ）。",[467,469,471,473,475],{"key":20,"text":468,"correct":22},"两个避难层（间）之间的高度不宜大于50m",{"key":24,"text":470,"correct":22},"通向避难层（间）的疏散楼梯应在避难层分隔、同层错位或上下层断开",{"key":28,"text":472,"correct":26},"避难层（间）的净面积应能满足设计避难人数避难的要求，并宜按6．0人／m2计算",{"key":31,"text":474,"correct":22},"避难层可兼作设备层",{"key":241,"text":476,"correct":22},"应设置消火栓和消防软管卷盘",{"id":478,"libraryId":5,"type":228,"typeLabel":229,"stem":479,"options":480,"answer":491,"analysis":33},932735,"某栋建筑高度为50m的高级旅馆，采用双面布房方式，已按现行有关国家工程建设消防技术标准设置了自动喷水灭火系统和火灾自动报警系统。下列关于该建筑内疏散走道的消防设计，表述正确的是（）。",[481,483,485,487,489],{"key":20,"text":482,"correct":22},"二层及以上各层楼板采用现浇的整体式梁板，耐火极限为1．00h",{"key":24,"text":484,"correct":26},"地上部分的疏散走道采用矿棉装饰吸声板吊顶，耐火极限不限",{"key":28,"text":486,"correct":22},"位于两个安全出口之间的直通疏散走道的房间内任一点至最近安全出口的最不利直线距离为56．25m",{"key":31,"text":488,"correct":26},"双面布房的疏散走道净宽度为1．3m",{"key":241,"text":490,"correct":22},"地上部分的疏散走道墙面可采用难燃PVC塑料护墙板装饰","ACE",{"id":493,"libraryId":5,"type":228,"typeLabel":229,"stem":494,"options":495,"answer":491,"analysis":33},932736,"以下关于防烟楼梯间的说法正确的有（）。",[496,498,500,502,504],{"key":20,"text":497,"correct":22},"防烟楼梯间可与消防电梯间前室合用前室",{"key":24,"text":499,"correct":26},"楼梯间墙体应采用耐火极限不低于3．00h的防火隔墙",{"key":28,"text":501,"correct":22},"除楼梯间和前室的出入口、楼梯间和前室内设置的正压送风口和住宅建筑的楼梯间前室外，防烟楼梯间及其前室的内墙上不应开设其他门、窗、洞口。",{"key":31,"text":503,"correct":26},"前室通向楼梯间的门必须为甲级防火门",{"key":241,"text":505,"correct":22},"楼梯间地面的装修材料必须采用不燃烧材料",{"id":507,"libraryId":5,"type":228,"typeLabel":229,"stem":508,"options":509,"answer":462,"analysis":33},932737,"高层建筑封闭楼梯间的门可以是（ ）。",[510,512,514,516,518],{"key":20,"text":511,"correct":26},"双向弹簧门",{"key":24,"text":513,"correct":22},"甲级防火门",{"key":28,"text":515,"correct":22},"乙级防火门",{"key":31,"text":517,"correct":26},"丙级防火门",{"key":241,"text":519,"correct":26},"向疏散方向开启的普通门",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":28,"analysis":33},932738,"某小型会议室，在计算有会议桌场所疏散人员密度时，下列选项符合要求的是（ ）。",[524,526,528,530],{"key":20,"text":525,"correct":26},"1.6人／m2",{"key":24,"text":527,"correct":26},"0.8人／m2",{"key":28,"text":529,"correct":22},"1.8m2／人",{"key":31,"text":531,"correct":26},"1.0m2／人",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":28,"analysis":33},932739,"某二级耐火等级的会议厅，共设有固定座位1200个，则该多功能厅的设计疏散人数不宜大于（ ）人。",[536,538,540,542],{"key":20,"text":537,"correct":26},"1100",{"key":24,"text":539,"correct":26},"1200",{"key":28,"text":541,"correct":22},"1320",{"key":31,"text":543,"correct":26},"1400",{"id":545,"libraryId":5,"type":15,"typeLabel":16,"stem":546,"options":547,"answer":24,"analysis":33},932740,"某一级耐火等级的体育馆，建筑高度24m，地上5层，有固定座位数8000个，则该体育馆供观众疏散的楼梯最小疏散总净总宽度不应小于（ ）m。",[548,550,552,554],{"key":20,"text":549,"correct":26},"40",{"key":24,"text":551,"correct":22},"34．4",{"key":28,"text":553,"correct":26},"29．6",{"key":31,"text":555,"correct":26},"50",{"id":557,"libraryId":5,"type":15,"typeLabel":16,"stem":558,"options":559,"answer":24,"analysis":33},932741,"某一级耐火等级电影院，设有6个观众厅，每个厅、室可容纳120人，则观众厅内疏散走道的净宽度不应小于（ ）m。",[560,562,563,565],{"key":20,"text":561,"correct":26},"0．72",{"key":24,"text":39,"correct":22},{"key":28,"text":564,"correct":26},"0．9",{"key":31,"text":566,"correct":26},"1．2",{"id":568,"libraryId":5,"type":15,"typeLabel":16,"stem":569,"options":570,"answer":28,"analysis":33},932742,"某办公楼，建筑高度24m，地上6层，耐火等级为二级，首层设计疏散人数为1600人，地上二层和三层的设计疏散人数均为1800人，四层及以上设计疏散人数为2000人，则该办公楼第二层疏散楼梯的最小疏散总净宽度不应小于（ ）m。",[571,572,574,575],{"key":20,"text":156,"correct":26},{"key":24,"text":573,"correct":26},"18",{"key":28,"text":91,"correct":22},{"key":31,"text":89,"correct":26},{"id":577,"libraryId":5,"type":15,"typeLabel":16,"stem":578,"options":579,"answer":31,"analysis":33},932743,"某单层地下网吧，层高5m，建筑面积1600m2，该网吧安全出口疏散总净宽度不应小于（ ）m。",[580,582,583,584],{"key":20,"text":581,"correct":26},"32",{"key":24,"text":156,"correct":26},{"key":28,"text":69,"correct":26},{"key":31,"text":79,"correct":22},{"id":586,"libraryId":5,"type":15,"typeLabel":16,"stem":587,"options":588,"answer":24,"analysis":33},932744,"某住宅建筑，建筑高度16m，疏散楼梯一侧设有栏杆，该疏散楼梯的净宽度不应小于（ ）m。",[589,591,592,594],{"key":20,"text":590,"correct":26},"0．5",{"key":24,"text":39,"correct":22},{"key":28,"text":593,"correct":26},"1．1",{"key":31,"text":595,"correct":26},"0． 9",{"id":597,"libraryId":5,"type":15,"typeLabel":16,"stem":598,"options":599,"answer":31,"analysis":33},932745,"某体育馆前后排座椅的排距为1m，靠墙侧座位仅有一侧有纵走道，该纵走道至墙之间的座位数不宜超过（ ）个。",[600,602,604,605],{"key":20,"text":601,"correct":26},"22",{"key":24,"text":603,"correct":26},"26",{"key":28,"text":555,"correct":26},{"key":31,"text":606,"correct":22},"25",{"id":608,"libraryId":5,"type":15,"typeLabel":16,"stem":609,"options":610,"answer":24,"analysis":33},932746,"某高层印刷厂，耐火等级为一级，厂房内任一点至最近安全出口的直线距离不应大于（ ）m。",[611,613,614,615],{"key":20,"text":612,"correct":26},"30",{"key":24,"text":549,"correct":22},{"key":28,"text":555,"correct":26},{"key":31,"text":616,"correct":26},"60",{"id":618,"libraryId":5,"type":15,"typeLabel":16,"stem":619,"options":620,"answer":20,"analysis":33},932747,"某一级耐火等级的单层敌敌畏合成厂房，设有自动喷水灭火系统保护，厂房内任一点至最近安全出口的直线距离不应大于（ ）m。",[621,622,623,624],{"key":20,"text":612,"correct":22},{"key":24,"text":606,"correct":26},{"key":28,"text":555,"correct":26},{"key":31,"text":616,"correct":26},{"id":626,"libraryId":5,"type":15,"typeLabel":16,"stem":627,"options":628,"answer":31,"analysis":33},932748,"某单独建造的一级耐火等级旅馆，地上6层，层高5m，每层建筑面积为1600m2，采用封闭楼梯间，设有相应的消防设施，位于两个安全出口之间的疏散门至最近的安全出口之间的距离不应大于（ ）m。",[629,630,631,633],{"key":20,"text":606,"correct":26},{"key":24,"text":612,"correct":26},{"key":28,"text":632,"correct":26},"35",{"key":31,"text":634,"correct":22},"37．5",{"id":636,"libraryId":5,"type":15,"typeLabel":16,"stem":637,"options":638,"answer":31,"analysis":33},932749,"某医院病房楼，地上5层，建筑高度25m，该建筑按现行消防技术标准设置了相应消防设施。当建筑内房间门位于两个安全出口之间时，该房间内任意一点至最近的安全出口之间的直线距离不应大于（ ）m。",[639,641,642,644],{"key":20,"text":640,"correct":26},"24",{"key":24,"text":89,"correct":26},{"key":28,"text":643,"correct":26},"36",{"key":31,"text":645,"correct":22},"45",[647,650,653,656,659,662],{"id":15,"name":648,"category":7,"favorite":649},"领导干部任职前廉政法规知识测试题",92,{"id":651,"name":652,"category":7,"favorite":15},595,"建筑结构与设备",{"id":654,"name":655,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":657,"name":658,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":660,"name":661,"category":7,"favorite":8},534,"BIM工程师",{"id":663,"name":661,"category":7,"favorite":8},535]