[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-2":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":625},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,2,50,2960,[13,34,46,58,70,82,99,111,123,135,147,156,166,178,190,202,214,225,237,249,261,273,285,300,312,327,339,347,361,376,388,402,416,424,436,451,463,475,487,499,511,520,532,541,549,561,575,589,601,613],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":30,"analysis":33},931727,1,"单选题","（2020年真题）某学校有甲、乙两座教学楼，甲教学楼一起火灾的消防用水设计流量为30L\u002Fs，乙教学楼一起火灾的消防用水设计流量为40L\u002Fs，两座教学楼共用消防给水系统，该系统一起火灾的消防用水设计流量至少应为（ ）L\u002Fs。",[19,23,26,29],{"key":20,"text":21,"correct":22},"A","60",false,{"key":24,"text":25,"correct":22},"B","70",{"key":27,"text":28,"correct":22},"C","80",{"key":30,"text":31,"correct":32},"D","40",true,"",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":30,"analysis":33},931728,"（2020年真题）下列建筑或场所中,可不设置室外消火栓系统的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"耐火等级为一级、建筑体积为2700m3的酚醛泡沫加工厂房",{"key":24,"text":41,"correct":22},"耐火等级为二级、建筑体积为2500m3的钢铁热轧厂房",{"key":27,"text":43,"correct":22},"居住总人数为500人、建筑层数均为3层的住宅小区",{"key":30,"text":45,"correct":32},"耐火等级为二级、建筑体积为2900m3的汽车装配厂房",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":24,"analysis":33},931729,"（2020年真题）下列场所中，应设置消防洒水软管或轻便消防水龙的是（ ）",[50,52,54,56],{"key":20,"text":51,"correct":22},"建筑高度为30m的丙类厂房",{"key":24,"text":53,"correct":32},"建筑高度为24m的商场",{"key":27,"text":55,"correct":22},"建筑高度为28m的住宅",{"key":30,"text":57,"correct":22},"建筑面积为180㎡的商业服务网点",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":24,"analysis":33},931730,"（2020年真题）某建筑高度为25m的5层工业厂房，设有室内消火栓系统，该厂房最不利点室内消火栓的栓口动压至少应为（ ）MPa。",[62,64,66,68],{"key":20,"text":63,"correct":22},"0.10",{"key":24,"text":65,"correct":32},"0.35",{"key":27,"text":67,"correct":22},"0.15",{"key":30,"text":69,"correct":22},"0.25",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":24,"analysis":33},931731,"（2020年真题）某石化厂工艺装置区的周边道路平面布局为矩形，两条东西方向道路的长度均为360m,两条南北方向道路的长度均为120m，根据现行国家标准《消防给水及消防栓系统技术规范》（GB50974）,该道路上至少应布置（ ）个室外消火栓。",[74,76,78,80],{"key":20,"text":75,"correct":22},"8",{"key":24,"text":77,"correct":32},"16",{"key":27,"text":79,"correct":22},"12",{"key":30,"text":81,"correct":22},"20",{"id":83,"libraryId":5,"type":9,"typeLabel":84,"stem":85,"options":86,"answer":98,"analysis":33},931733,"多选题","（2016真题）某高层建筑，建筑高度50m，设有3台湿式报警阀。下列关于末端试水装置设置的说法中，正确的有（ ）。",[87,89,91,93,95],{"key":20,"text":88,"correct":22},"每层最不利点喷头处均应设施末端试水设置",{"key":24,"text":90,"correct":22},"末端试水装置的出流量应由系统流量系数最大的喷头确定",{"key":27,"text":92,"correct":32},"末端试水装置应由试水阀、压力表、试水接头组成",{"key":30,"text":94,"correct":32},"末端试水装置的出水应采取孔口出流的方式排入排水管道",{"key":96,"text":97,"correct":32},"E","末端试水装置处排水管道的直径不宜小于DN75","CDE",{"id":100,"libraryId":5,"type":15,"typeLabel":16,"stem":101,"options":102,"answer":27,"analysis":33},931734,"（2017真题）下列自动喷水灭灭系统中,属于开式系统的是（ ）。",[103,105,107,109],{"key":20,"text":104,"correct":22},"湿式系统",{"key":24,"text":106,"correct":22},"干式系统",{"key":27,"text":108,"correct":32},"雨淋系统",{"key":30,"text":110,"correct":22},"预作用系统",{"id":112,"libraryId":5,"type":15,"typeLabel":16,"stem":113,"options":114,"answer":27,"analysis":33},931735,"（2017真题）湿式自动喷水灭火系统的喷淋泵,应由（ ）信号直接控制启动。",[115,117,119,121],{"key":20,"text":116,"correct":22},"信号阀",{"key":24,"text":118,"correct":22},"水流指示器",{"key":27,"text":120,"correct":32},"压力开关",{"key":30,"text":122,"correct":22},"消防联动控制器",{"id":124,"libraryId":5,"type":15,"typeLabel":16,"stem":125,"options":126,"answer":20,"analysis":33},931736,"（2015真题）某消防技术服务机构承接了某仓库干式自动喷水灭火系统维保工作，在对差动式干式报警阀进行检查时，发现安装在通往延迟器管道上的小孔排水阀偶尔有水滴滴出，但报警阀启动后就不滴了。下列关于此情况的说法中，正确的是（ ）。",[127,129,131,133],{"key":20,"text":128,"correct":32},"报警阀正常",{"key":24,"text":130,"correct":22},"报警阀故障，应拆下报警组进行检修",{"key":27,"text":132,"correct":22},"报警阀故障，应立即堵住排水阀出口",{"key":30,"text":134,"correct":22},"报警阀故障，但影响不大，暂不采取措施",{"id":136,"libraryId":5,"type":15,"typeLabel":16,"stem":137,"options":138,"answer":27,"analysis":33},931737,"（2015真题）某座3100个座位的大剧院，地下车库采用预作用自动喷水灭火系统，演员化妆间等采用湿式自动喷水灭火系统，舞台葡萄架下采用雨淋系统，舞台口采用防护冷却水幕系统。该建筑的自动喷水灭火系统应选用（）种报警阀组。",[139,141,143,145],{"key":20,"text":140,"correct":22},"1",{"key":24,"text":142,"correct":22},"2",{"key":27,"text":144,"correct":32},"3",{"key":30,"text":146,"correct":22},"4",{"id":148,"libraryId":5,"type":15,"typeLabel":16,"stem":149,"options":150,"answer":27,"analysis":33},931738,"（2015真题）某3层商业建筑，采用湿式自动喷水灭火系统保护，共设计有2800个喷头保护吊顶下方空间。该建筑自动喷水灭火系统报警阀组的设置数量不应少于（ ）个。",[151,152,153,154],{"key":20,"text":142,"correct":22},{"key":24,"text":144,"correct":22},{"key":27,"text":146,"correct":32},{"key":30,"text":155,"correct":22},"5",{"id":157,"libraryId":5,"type":15,"typeLabel":16,"stem":158,"options":159,"answer":27,"analysis":33},931739,"（2017真题）发生火灾时，湿式喷水灭火系统的湿式报警阀由（ ）开启。",[160,162,163,165],{"key":20,"text":161,"correct":22},"火灾探测器",{"key":24,"text":118,"correct":22},{"key":27,"text":164,"correct":32},"闭式喷头",{"key":30,"text":120,"correct":22},{"id":167,"libraryId":5,"type":15,"typeLabel":16,"stem":168,"options":169,"answer":24,"analysis":33},931740,"（2015真题）在环境温度低于4℃的地区，建设一座地下车库，采用干式自动喷水灭火系统保护，系统的设计参数按照火灾危险等级的中危险级Ⅱ级确定，其作用面积不应小于（ ）m2。",[170,172,174,176],{"key":20,"text":171,"correct":22},"160",{"key":24,"text":173,"correct":32},"208",{"key":27,"text":175,"correct":22},"192",{"key":30,"text":177,"correct":22},"260",{"id":179,"libraryId":5,"type":15,"typeLabel":16,"stem":180,"options":181,"answer":20,"analysis":33},931741,"（2016真题）下列关于自动喷水灭火系统的说法中，错误的是（）。",[182,184,186,188],{"key":20,"text":183,"correct":32},"雨淋系统与预作用系统均应采用开式洒水喷头",{"key":24,"text":185,"correct":22},"干式系统和预作用系统的配水管道应设置快速排气阀",{"key":27,"text":187,"correct":22},"雨淋系统应能有由套的火灾自动报警系统或传动管控制并启动雨淋系统",{"key":30,"text":189,"correct":22},"预作用系统应由火灾自动报警系统自动开启雨淋报警阀，并转换为湿式系统",{"id":191,"libraryId":5,"type":15,"typeLabel":16,"stem":192,"options":193,"answer":27,"analysis":33},931742,"（2016真题）下列关于干式自动喷水灭火系统的说法中，错误的是（ ）。",[194,196,198,200],{"key":20,"text":195,"correct":22},"在准工作状态下，由稳压系统维持干式报警阀入口前管道内的充水压力",{"key":24,"text":197,"correct":22},"在准工作状态下，干式报警阀出口后的配水管道内应充满有压气体",{"key":27,"text":199,"correct":32},"当发生火灾后，干式报警阀开启，压力开关动作后管网开始排气充水",{"key":30,"text":201,"correct":22},"当发生火灾后，配水管道排气充水后，开启的喷头开始喷水",{"id":203,"libraryId":5,"type":15,"typeLabel":16,"stem":204,"options":205,"answer":20,"analysis":33},931743,"（2015真题）某单层工业厂房，建筑面积10000m2，室内最大净高为8m，屋面坡度为2%，未设置吊顶。该建筑按中危险级Ⅱ级设置自动喷水灭火系统，应选择（ ）喷头。",[206,208,210,212],{"key":20,"text":207,"correct":32},"直立型",{"key":24,"text":209,"correct":22},"隐蔽型",{"key":27,"text":211,"correct":22},"吊顶型",{"key":30,"text":213,"correct":22},"边墙型",{"id":215,"libraryId":5,"type":15,"typeLabel":16,"stem":216,"options":217,"answer":20,"analysis":33},931744,"（2015真题）设置湿式自动喷水灭火系统的房间，起火时喷头动作喷水，水流指示器动作并报警，报警阀动作，延迟器充水，启泵装置动作报警并直接启动消防水泵，该系统应选择的启泵装置是（ ）。",[218,219,221,223],{"key":20,"text":120,"correct":32},{"key":24,"text":220,"correct":22},"电接点压力表",{"key":27,"text":222,"correct":22},"流量开关",{"key":30,"text":224,"correct":22},"水位仪",{"id":226,"libraryId":5,"type":15,"typeLabel":16,"stem":227,"options":228,"answer":20,"analysis":33},931745,"（2015真题）自动喷水灭火系统设置场所的危险等级应根据建筑规模、高度以及火灾危险性、火灾荷载和保护对象的特点等确定。下列建筑中，自动喷水灭火系统设置场所的火灾危险等级为中危险级I级的是（ ）。",[229,231,233,235],{"key":20,"text":230,"correct":32},"建筑高度为50m的办公楼",{"key":24,"text":232,"correct":22},"建筑高度为23m的四星级旅馆",{"key":27,"text":234,"correct":22},"2000个座位剧场的舞台",{"key":30,"text":236,"correct":22},"总建筑面积5600㎡的商场",{"id":238,"libraryId":5,"type":15,"typeLabel":16,"stem":239,"options":240,"answer":27,"analysis":33},931746,"（2018真题）某剧场舞台设有雨淋系统，雨淋报警阀采用充水传动管控制。该雨淋系统消防水泵的下列控制方案中，错误的是（ ）。",[241,243,245,247],{"key":20,"text":242,"correct":22},"由报警阀组压力开关信号直接连锁启动消防喷淋泵",{"key":24,"text":244,"correct":22},"由高位水箱出水管上设置的流量开关直接自动启动消防喷淋泵",{"key":27,"text":246,"correct":32},"由火灾自动报警系统报警信号直接自动启动消防喷淋泵",{"key":30,"text":248,"correct":22},"由消防水泵出水干管上设置的压力开关直接自动启动消防喷淋泵",{"id":250,"libraryId":5,"type":15,"typeLabel":16,"stem":251,"options":252,"answer":30,"analysis":33},931747,"（2018真题）某场所内设置自动喷水灭火系统，洒水喷头玻璃球工作液色标为黄色，则该洒水喷头公称动作温度为（ ）",[253,255,257,259],{"key":20,"text":254,"correct":22},"57℃",{"key":24,"text":256,"correct":22},"68℃",{"key":27,"text":258,"correct":22},"93℃",{"key":30,"text":260,"correct":32},"79℃",{"id":262,"libraryId":5,"type":15,"typeLabel":16,"stem":263,"options":264,"answer":24,"analysis":33},931748,"（2018真题）某百货商场，地上4层，每层建筑面积均为1500m3，层高均为5.2m，该商场的营业厅设置自动喷水灭火系统，该自动喷水灭火系统最低喷水强度应为（ ）。",[265,267,269,271],{"key":20,"text":266,"correct":22},"4L\u002F（min.m3）",{"key":24,"text":268,"correct":32},"8L\u002F（min.m3）",{"key":27,"text":270,"correct":22},"6L\u002F（min.m3）",{"key":30,"text":272,"correct":22},"12L\u002F（min m3）",{"id":274,"libraryId":5,"type":15,"typeLabel":16,"stem":275,"options":276,"answer":24,"analysis":33},931749,"（2018真题）某冷库冷藏室室内净高为4.5m，设计温度为5℃，冷藏间内设有自动喷水灭火系统，该冷藏间自动喷水灭火系统的下列设计方案中，正确的是（ ）。",[277,279,281,283],{"key":20,"text":278,"correct":22},"采用干式系统，选用公称动作温度为68℃的喷头",{"key":24,"text":280,"correct":32},"采用湿式系统，选用公称动作温为57℃的喷头",{"key":27,"text":282,"correct":22},"采用预作用系统，选用公称动作温度为79℃的喷头",{"key":30,"text":284,"correct":22},"采用雨淋系统，选用水幕喷头",{"id":286,"libraryId":5,"type":9,"typeLabel":84,"stem":287,"options":288,"answer":299,"analysis":33},931750,"（2015真题）某地下车库，设置的自动喷水灭火系统采用直立型喷头，下列关于喷头溅水盘与车库顶板的垂直距离的说法，符合规范规定的有（ ）。",[289,291,293,295,297],{"key":20,"text":290,"correct":22},"喷头无障碍物遮挡时，不应小于25mm，不应大于150mm",{"key":24,"text":292,"correct":22},"喷头有障碍物遮挡时，不应大于850mm",{"key":27,"text":294,"correct":32},"喷头无障碍物遮挡时，不应小于75mm，不应大于150mm",{"key":30,"text":296,"correct":22},"喷头有障碍物遮挡时，不应大于650mm",{"key":96,"text":298,"correct":32},"喷头有障碍物遮挡时，不应大于550mm","CE",{"id":301,"libraryId":5,"type":15,"typeLabel":16,"stem":302,"options":303,"answer":20,"analysis":33},931751,"（2018真题）根据现行国家标准《自动喷水灭火系统设计规范》（GB 50084），下列自动喷水灭火系统组件中，可组成防护冷却系统的是（ ）。",[304,306,308,310],{"key":20,"text":305,"correct":32},"闭式洒水喷头、湿式报警阀组",{"key":24,"text":307,"correct":22},"开式洒水喷头，雨淋报警阀组",{"key":27,"text":309,"correct":22},"水幕喷头、雨淋报警阀组",{"key":30,"text":311,"correct":22},"闭式洒水喷头、干式报警阀组",{"id":313,"libraryId":5,"type":9,"typeLabel":84,"stem":314,"options":315,"answer":326,"analysis":33},931752,"（2016真题）某建筑高度为25M的办公建筑，地上部分全部为办公，地下2层为汽车库，建筑内部全部设置自动喷水灭火系统，下列关于该自动喷水灭火系统的做法中，正确的有（ ）",[316,318,320,322,324],{"key":20,"text":317,"correct":32},"办公楼层采用玻璃球色标为红色的喷头",{"key":24,"text":319,"correct":22},"办公楼采用边墙型喷头",{"key":27,"text":321,"correct":32},"汽车库内一只喷头的最大保护面积为11.5㎡",{"key":30,"text":323,"correct":32},"汽车库采用直立型喷头",{"key":96,"text":325,"correct":22},"办公楼层内一只喷头的最大保护面积为20.0㎡","ACD",{"id":328,"libraryId":5,"type":15,"typeLabel":16,"stem":329,"options":330,"answer":20,"analysis":33},931753,"（2016真题）某总建筑面积为5200㎡的百货商场，其营业厅的室内净高为5.8m，所设置的自动喷水灭火系统的设计参数应按火灾危险等级不低于（ ）确定。",[331,333,335,337],{"key":20,"text":332,"correct":32},"中危险Ⅱ级",{"key":24,"text":334,"correct":22},"严重危险Ⅱ级",{"key":27,"text":336,"correct":22},"严重危险I级",{"key":30,"text":338,"correct":22},"中危险I级",{"id":340,"libraryId":5,"type":15,"typeLabel":16,"stem":341,"options":342,"answer":27,"analysis":33},931754,"（2016真题）某2层地上商店建筑，每层建筑而积为6000㎡，所设置的自动喷水灭火系统应至少设置（ ）个水流指示器。",[343,344,345,346],{"key":20,"text":142,"correct":22},{"key":24,"text":144,"correct":22},{"key":27,"text":146,"correct":32},{"key":30,"text":155,"correct":22},{"id":348,"libraryId":5,"type":9,"typeLabel":84,"stem":349,"options":350,"answer":98,"analysis":33},931755,"（2016真题）某3层图书馆,建筑面积为12000m2,室内最大净空高度为4.5m,图书馆内全部设置自动喷水灭火系统等,下列关于该自动喷水灭火系统的法中,正确的有（ ）。",[351,353,355,357,359],{"key":20,"text":352,"correct":22},"系统的喷水强度为4L\u002F（min.m2）",{"key":24,"text":354,"correct":22},"共设置1套湿式报警阀组",{"key":27,"text":356,"correct":32},"来用流量系数K=80的洒水喷头",{"key":30,"text":358,"correct":32},"系统的作用面积为160m2",{"key":96,"text":360,"correct":32},"系统最不利点处喷头的工作压力为0.1MP",{"id":362,"libraryId":5,"type":9,"typeLabel":84,"stem":363,"options":364,"answer":375,"analysis":33},931756,"（2018真题）根据现行国家标准《自动喷水灭火系统设计规范》(GB 50084)，下列湿式自动喷水灭火系统消防水泵控制方案中，正确的有（）。",[365,367,369,371,373],{"key":20,"text":366,"correct":22},"由消防水泵出水干管上设置的压力开关动作信号与高位水箱出水管，上设置的流量开关信号作为联动与触发信号，自动启动消防喷淋泵",{"key":24,"text":368,"correct":22},"由高位水箱出水管上设置的流量开关动作信号与火灾自动报警系统报警信号作为联动与触发信号，自动启动消防喷淋泵",{"key":27,"text":370,"correct":22},"由消防水泵出水干管上设置的压力开关动作信号与火灾自动报警系统报警信号作为联动与触发信号，直接自动启动消防喷淋泵",{"key":30,"text":372,"correct":32},"火灾自动报警联动控制器处于手动状态时，由报警阀组压力开关动作信号作为触发信号，直接控制启动消防喷淋泵",{"key":96,"text":374,"correct":32},"火灾自动报警联动控制器处于自动状态时，由高位水箱出水管上设置的流量开关信号作为触发信号，直接自动启动消防喷淋泵","DE",{"id":377,"libraryId":5,"type":9,"typeLabel":84,"stem":378,"options":379,"answer":387,"analysis":33},931757,"（2017真题）末端试水装置开启后，（ ）等组件和喷淋泵应动作。",[380,381,383,384,385],{"key":20,"text":118,"correct":32},{"key":24,"text":382,"correct":32},"水力警铃",{"key":27,"text":164,"correct":22},{"key":30,"text":120,"correct":32},{"key":96,"text":386,"correct":32},"湿式报警阀","ABDE",{"id":389,"libraryId":5,"type":9,"typeLabel":84,"stem":390,"options":391,"answer":387,"analysis":33},931758,"（2018真题）下列建筑场所湿式自动喷水灭火系统喷头选型方案中，正确的有（ ）。",[392,394,396,398,400],{"key":20,"text":393,"correct":32},"办公楼附建的地下汽车库，选用直立型洒水喷头",{"key":24,"text":395,"correct":32},"装有非通透性吊项的商场；选用下垂型洒水喷头",{"key":27,"text":397,"correct":22},"总建筑面积为 5000 ㎡的地下商场；选用隐蔽式洒水喷头",{"key":30,"text":399,"correct":32},"多层旅馆客房；选用边墙型洒水喷头",{"key":96,"text":401,"correct":32},"工业园区员工集体宿舍；选用家用喷头",{"id":403,"libraryId":5,"type":9,"typeLabel":84,"stem":404,"options":405,"answer":98,"analysis":33},931759,"（2018真题）下列民用建筑（场所）自动喷水灭火系统参数设计方案中，正确的有（ ）。 {图}",[406,408,410,412,414],{"key":20,"text":407,"correct":22},"方案 4",{"key":24,"text":409,"correct":22},"方案 5",{"key":27,"text":411,"correct":32},"方案 1",{"key":30,"text":413,"correct":32},"方案 2",{"key":96,"text":415,"correct":32},"方案 3",{"id":417,"libraryId":5,"type":15,"typeLabel":16,"stem":418,"options":419,"answer":20,"analysis":33},931760,"（2019年真题）某油漆喷涂车间， 拟采用自动喷水灭火系统，该灭火系统应采用（）",[420,421,422,423],{"key":20,"text":108,"correct":32},{"key":24,"text":104,"correct":22},{"key":27,"text":106,"correct":22},{"key":30,"text":110,"correct":22},{"id":425,"libraryId":5,"type":15,"typeLabel":16,"stem":426,"options":427,"answer":20,"analysis":33},931761,"（2019年真题）某商场内的防火卷帘采用水幕系统进行防护冷却，喷头设置高度为7m,水幕系统的喷水强度不应小于()。",[428,430,432,434],{"key":20,"text":429,"correct":32},"0.8L\u002F(s.m)",{"key":24,"text":431,"correct":22},"0.9L\u002F(s.m)",{"key":27,"text":433,"correct":22},"0.6L\u002F(s.m)",{"key":30,"text":435,"correct":22},"0.7L\u002F(s.m)",{"id":437,"libraryId":5,"type":9,"typeLabel":84,"stem":438,"options":439,"answer":450,"analysis":33},931762,"（2019年真题）某单层非密集柜式档案馆，建筑高度为71， 自动喷水灭火系统采用预作用系统，该预作用系统的喷头应采用()",[440,442,444,446,448],{"key":20,"text":441,"correct":22},"下垂型标准响应喷头",{"key":24,"text":443,"correct":32},"直立型标准响应喷头",{"key":27,"text":445,"correct":22},"下垂型快速响应喷头",{"key":30,"text":447,"correct":32},"干式下垂型标准响应喷头",{"key":96,"text":449,"correct":22},"直立型快速响应喷头","BD",{"id":452,"libraryId":5,"type":15,"typeLabel":16,"stem":453,"options":454,"answer":20,"analysis":33},931763,"（2019年真题）某酒店地上11层，地下2层，每层1个防火分区，该酒店设置了1套自动喷水灭火系统，在第十一层设有两种喷头，流量系数分别为80和115。该系统末端试水装备的设置，错误的是()",[455,457,459,461],{"key":20,"text":456,"correct":32},"末端试水装置的出水采用软管连接排入排水管道",{"key":24,"text":458,"correct":22},"未端试水装备设置在第十一层",{"key":27,"text":460,"correct":22},"未端试水装置选用出水口流量系数为80的试水接头",{"key":30,"text":462,"correct":22},"未端试水装置由试水阀，压力表和试水接头组成",{"id":464,"libraryId":5,"type":15,"typeLabel":16,"stem":465,"options":466,"answer":24,"analysis":33},931764,"（2019年真题）某地下商场，总建筑面积为2500㎡，净高7m,装有网格吊顶，吊顶通透面积占吊顶总面积的75%，采用的自动喷水灭火系统为湿式系统，该系列的下列喷头选型中，正确的是（）",[467,469,471,473],{"key":20,"text":468,"correct":22},"选用隐蔽型洒水喷头",{"key":24,"text":470,"correct":32},"选用RTI为28 (m.s) ^0. 5的直立型酒水喷头",{"key":27,"text":472,"correct":22},"选用吊顶型洒水喷头",{"key":30,"text":474,"correct":22},"靠近端墙的部位，选用边墙型洒水喷头",{"id":476,"libraryId":5,"type":15,"typeLabel":16,"stem":477,"options":478,"answer":24,"analysis":33},931765,"（2019年真题）某剧院舞台葡萄架下设有雨淋系统，雨淋报警阀组设置在舞台附近；距离消防泵房30m处。关于该雨淋报警阀组控制方式的说法，错误的是（）",[479,481,483,485],{"key":20,"text":480,"correct":22},"可采用火灾自动报警系统自动控制开启雨淋报警阀组",{"key":24,"text":482,"correct":32},"应能够在消防泵房远程控制开启雨淋报警阀组",{"key":27,"text":484,"correct":22},"应能够在消防控制室远程控制开启雨淋报警阀组",{"key":30,"text":486,"correct":22},"应能够在雨淋报警阀处现场手动机械开启雨淋报警阀组",{"id":488,"libraryId":5,"type":15,"typeLabel":16,"stem":489,"options":490,"answer":24,"analysis":33},931766,"（2020年真题）某液化石油气储配站，日装瓶量为4000瓶,该储配站的灌瓶间应设置（ ）。",[491,493,495,497],{"key":20,"text":492,"correct":22},"泡沫灭火系统",{"key":24,"text":494,"correct":32},"雨淋自动喷水灭火系统",{"key":27,"text":496,"correct":22},"干粉灭火系统",{"key":30,"text":498,"correct":22},"细水雾灭火系统",{"id":500,"libraryId":5,"type":15,"typeLabel":16,"stem":501,"options":502,"answer":27,"analysis":33},931767,"（2020年真题）某常年存储温度为2℃的仓库设置了预作用自动喷水灭火系统。发生火灾时，该仓库灭火系统的预作用报警阀组和消防水泵可分别由（ ）联锁控制。",[503,505,507,509],{"key":20,"text":504,"correct":22},"手动火灾报警按钮和配水管道上的水流指示器",{"key":24,"text":506,"correct":22},"消防联动控制器和配水管道上的排气阀",{"key":27,"text":508,"correct":32},"消防联动控制器和报警阀组的压力开关",{"key":30,"text":510,"correct":22},"火灾探测器和预作用装置上的电磁阀",{"id":512,"libraryId":5,"type":15,"typeLabel":16,"stem":513,"options":514,"answer":24,"analysis":33},931768,"（2020年真题）某建筑高度为24m的商场，地上5层，建筑面积36000m2,商场设有格栅吊项。吊顶的通透面积占吊顶总面积的85%，该商场设有湿式自动喷水灭火系统，系统配水支管布置在梁下，该商场设置的自动喷水灭火系统应采用（ ）洒水喷头。",[515,516,517,518],{"key":20,"text":213,"correct":22},{"key":24,"text":207,"correct":32},{"key":27,"text":209,"correct":22},{"key":30,"text":519,"correct":22},"下垂型",{"id":521,"libraryId":5,"type":15,"typeLabel":16,"stem":522,"options":523,"answer":27,"analysis":33},931769,"（2020年真题）预作用自动喷水灭火系统灭火流程包括以下环节:①压力开关或流量开关动作;②喷淋泵启动;③预作用报警阀打开。系统动作顺序正确的是（ ）。",[524,526,528,530],{"key":20,"text":525,"correct":22},"③②①",{"key":24,"text":527,"correct":22},"①③②",{"key":27,"text":529,"correct":32},"③①②",{"key":30,"text":531,"correct":22},"①②③",{"id":533,"libraryId":5,"type":15,"typeLabel":16,"stem":534,"options":535,"answer":27,"analysis":33},931770,"（2020年真题）某商业建筑地下一层为超市，室内净空高度为6m，物品高度为4m。超市设置的湿式自动喷水灭火系统的喷水强度至少应为（ ）L\u002F（min.m2）。",[536,537,539,540],{"key":20,"text":146,"correct":22},{"key":24,"text":538,"correct":22},"6",{"key":27,"text":79,"correct":32},{"key":30,"text":75,"correct":22},{"id":542,"libraryId":5,"type":15,"typeLabel":16,"stem":543,"options":544,"answer":20,"analysis":33},931771,"（2020年真题）某省级电视台设有一个1500m2的演播室,演播室的自动喷水灭火系统应采用（ ）。",[545,546,547,548],{"key":20,"text":108,"correct":32},{"key":24,"text":104,"correct":22},{"key":27,"text":106,"correct":22},{"key":30,"text":110,"correct":22},{"id":550,"libraryId":5,"type":9,"typeLabel":84,"stem":551,"options":552,"answer":326,"analysis":33},931772,"（2020年真题）某单层甲等剧场的办公用房设有湿式自动喷水灭火系统,该系统报警阀组的组件包括（ ）。",[553,555,557,558,559],{"key":20,"text":554,"correct":32},"报警阀",{"key":24,"text":556,"correct":22},"防复位锁止机构",{"key":27,"text":382,"correct":32},{"key":30,"text":120,"correct":32},{"key":96,"text":560,"correct":22},"泄水阀",{"id":562,"libraryId":5,"type":9,"typeLabel":84,"stem":563,"options":564,"answer":98,"analysis":33},931773,"（2020年真题）某单层硝化棉仓库，建筑面积为150m2，该仓库设置的自动喷水灭火系统报警阀组可采用的控制方式有（ ）。",[565,567,569,571,573],{"key":20,"text":566,"correct":22},"末端试水装置启动",{"key":24,"text":568,"correct":22},"电动启动",{"key":27,"text":570,"correct":32},"液动启动",{"key":30,"text":572,"correct":32},"气动启动",{"key":96,"text":574,"correct":32},"现场应急启动",{"id":576,"libraryId":5,"type":9,"typeLabel":84,"stem":577,"options":578,"answer":387,"analysis":33},931774,"（2020年真题）下列设有自动喷水灭火系统的建筑或场所中,其自动喷水灭火系统应按中危险级Ⅰ级设置的有（ ）。",[579,581,583,585,587],{"key":20,"text":580,"correct":32},"高层医院",{"key":24,"text":582,"correct":32},"单层建筑面积为500m2的网吧",{"key":27,"text":584,"correct":22},"占地面积为2000m2的木器厂房",{"key":30,"text":586,"correct":32},"总建筑面积为4000m2的商场",{"key":96,"text":588,"correct":32},"国家文物保护单位",{"id":590,"libraryId":5,"type":15,"typeLabel":16,"stem":591,"options":592,"answer":24,"analysis":33},931775,"（2015真题）水喷雾灭火系统的水雾喷头使水从连续的水流状态分解转变成不连续的细小水雾滴喷射出来，因此它具有较高的电绝缘性能和良好的灭火性能。下列不属于水喷雾灭火机理的是（）。",[593,595,597,599],{"key":20,"text":594,"correct":22},"冷却",{"key":24,"text":596,"correct":32},"隔离",{"key":27,"text":598,"correct":22},"窒息",{"key":30,"text":600,"correct":22},"乳化",{"id":602,"libraryId":5,"type":15,"typeLabel":16,"stem":603,"options":604,"answer":24,"analysis":33},931776,"（2017真题）细水雾灭火系统按供水方式分类,可分为泵组式系统、瓶组与泵组结合式系统和（）。",[605,607,609,611],{"key":20,"text":606,"correct":22},"低压系统",{"key":24,"text":608,"correct":32},"瓶组式系统",{"key":27,"text":610,"correct":22},"中压系统",{"key":30,"text":612,"correct":22},"高压系统",{"id":614,"libraryId":5,"type":15,"typeLabel":16,"stem":615,"options":616,"answer":20,"analysis":33},931777,"（2016真题）下列关于采用传动管启动水喷雾灭火系统的做法中错误的是（）。",[617,619,621,623],{"key":20,"text":618,"correct":32},"雨淋报警阀组通过电动开启",{"key":24,"text":620,"correct":22},"系统利用闭式喷头探测火灾",{"key":27,"text":622,"correct":22},"雨淋报警阀组通过气动开启",{"key":30,"text":624,"correct":22},"雨淋报警阀组通过液动开启",[626,629,632,635,638,641],{"id":15,"name":627,"category":7,"favorite":628},"领导干部任职前廉政法规知识测试题",92,{"id":630,"name":631,"category":7,"favorite":15},595,"建筑结构与设备",{"id":633,"name":634,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":636,"name":637,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":639,"name":640,"category":7,"favorite":8},534,"BIM工程师",{"id":642,"name":640,"category":7,"favorite":8},535]