[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-19":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":597},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,19,50,2960,[13,38,53,68,83,97,111,123,135,147,158,170,179,190,202,214,226,238,247,259,271,283,292,300,312,322,333,341,353,365,374,386,400,415,430,440,455,470,482,494,504,513,525,533,545,556,564,572,580,588],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},932600,2,"多选题","下列关于工业建筑附属用房的布置，正确的有（ ）。",[19,23,27,30,33],{"key":20,"text":21,"correct":22},"A","空分厂房内设置有一员工休息室，采用耐火极限不低于 3.00h 的防爆墙隔开，且设置有独立的安全出口",false,{"key":24,"text":25,"correct":26},"B","某鱼类加工厂房内设置有办公室，采用耐火极限为 3.00h 的防火隔墙和 1.00h 的楼板与厂房隔开，设置有一个独立的安全出口",true,{"key":28,"text":29,"correct":22},"C","酚醛泡沫塑料仓库内设置的办公室，采用耐火极限为 2.00h 的防火隔墙和 1.00h 的楼板与库房分隔，设置有独立的安全出口",{"key":31,"text":32,"correct":26},"D","锅炉房内的柴油储罐（容积为 4.8m3），设置在单独房间内，该房间采用 耐火极限不低于 3.00h 的防火隔墙和 1.50h 的楼板与其他部位分隔，房间的门采用 甲级防火门",{"key":34,"text":35,"correct":22},"E","汽车装配车间设置有一轮胎仓库，采用耐火极限为 2.00h 的防火隔墙和 1.00h 的楼板与其他部位分隔。","BD","",{"id":39,"libraryId":5,"type":15,"typeLabel":16,"stem":40,"options":41,"answer":52,"analysis":37},932601,"下列选项中，防火间距确定的原则包括（ ）。",[42,44,46,48,50],{"key":20,"text":43,"correct":26},"防止火灾蔓延",{"key":24,"text":45,"correct":26},"节约土地资源",{"key":28,"text":47,"correct":26},"保障灭火救援场地需要",{"key":31,"text":49,"correct":26},"防火间距的计算",{"key":34,"text":51,"correct":22},"加速灭火","ABCD",{"id":54,"libraryId":5,"type":15,"typeLabel":16,"stem":55,"options":56,"answer":67,"analysis":37},932602,"柴油发电机房布置在民用建筑内时应符合的规定有（ ）。",[57,59,61,63,65],{"key":20,"text":58,"correct":22},"可以布置在地下三层及以下",{"key":24,"text":60,"correct":22},"门应采用乙级防火门",{"key":28,"text":62,"correct":26},"应设置火灾报警装置",{"key":31,"text":64,"correct":26},"应采用耐火极限不低于2．00h的防火隔墙与其他部位分隔",{"key":34,"text":66,"correct":26},"应设置与柴油发电机容量和建筑规模相适应的灭火设施","CDE",{"id":69,"libraryId":5,"type":15,"typeLabel":16,"stem":70,"options":71,"answer":82,"analysis":37},932603,"下列场所中，可布置在民用建筑的地下半地下的是（）。",[72,74,76,78,80],{"key":20,"text":73,"correct":26},"商店营业厅",{"key":24,"text":75,"correct":22},"儿童游乐厅",{"key":28,"text":77,"correct":26},"歌舞厅",{"key":31,"text":79,"correct":26},"网吧",{"key":34,"text":81,"correct":26},"消防水泵房","ACDE",{"id":84,"libraryId":5,"type":15,"typeLabel":16,"stem":85,"options":86,"answer":96,"analysis":37},932604,"下列布置在民用建筑内的场所,（）不应布置在人员密集场所的上一层、下一层或贴临。",[87,89,90,92,94],{"key":20,"text":88,"correct":26},"燃气锅炉房",{"key":24,"text":81,"correct":22},{"key":28,"text":91,"correct":26},"油浸变压器室",{"key":31,"text":93,"correct":26},"柴油发电机房",{"key":34,"text":95,"correct":22},"气体灭火系统储瓶间","ACD",{"id":98,"libraryId":5,"type":99,"typeLabel":100,"stem":101,"options":102,"answer":31,"analysis":37},932605,1,"单选题","下列建筑中，不属于老年人照料设施的是（ ）。",[103,105,107,109],{"key":20,"text":104,"correct":22},"床位数为20床的敬老院",{"key":24,"text":106,"correct":22},"床位数为30床的养老院",{"key":28,"text":108,"correct":22},"床位数为21床的老年人日间照料设施",{"key":31,"text":110,"correct":26},"座位数为50个的老年人活动中心",{"id":112,"libraryId":5,"type":99,"typeLabel":100,"stem":113,"options":114,"answer":31,"analysis":37},932606,"下列关于防火间距的确定原则的说法，不正确的是（ ）。",[115,117,119,121],{"key":20,"text":116,"correct":22},"防火间距应满足消防车的最大工作回转半径和扑救场地的需要",{"key":24,"text":118,"correct":22},"火灾发生时建筑物可能产生的热辐射强度是确定防火间距应考虑的主要因素",{"key":28,"text":120,"correct":22},"确定建筑之间的防火间距，需要考虑节约用地的因素",{"key":31,"text":122,"correct":26},"防火间距应按相邻建筑物凸出的不燃构件的最近距离计算",{"id":124,"libraryId":5,"type":99,"typeLabel":100,"stem":125,"options":126,"answer":20,"analysis":37},932607,"某三级耐火等级的单层氨压缩机房与二级耐火等级的燃煤锅炉房之间的防火间距（ ）。",[127,129,131,133],{"key":20,"text":128,"correct":26},"不宜小于30m",{"key":24,"text":130,"correct":22},"不应小于12m",{"key":28,"text":132,"correct":22},"不应小于30m",{"key":31,"text":134,"correct":22},"不宜小于12m",{"id":136,"libraryId":5,"type":99,"typeLabel":100,"stem":137,"options":138,"answer":28,"analysis":37},932608,"某新建煤粉厂房在确定防火间距时，与多层公共建筑之间的间距不应小于（ ）m。",[139,141,143,145],{"key":20,"text":140,"correct":22},"15",{"key":24,"text":142,"correct":22},"20",{"key":28,"text":144,"correct":26},"25",{"key":31,"text":146,"correct":22},"50",{"id":148,"libraryId":5,"type":99,"typeLabel":100,"stem":149,"options":150,"answer":31,"analysis":37},932609,"某耐火等级为二级的多层桐油制备厂房，附近新建一座耐火等级为二级的高层住宅楼，当住宅楼外墙与厂房相邻侧均采用不开设门、窗、洞口的防火墙时，两座建筑之间的防火间距（ ）。",[151,153,155,156],{"key":20,"text":152,"correct":22},"不应小于5m",{"key":24,"text":154,"correct":22},"不应小于10m",{"key":28,"text":130,"correct":22},{"key":31,"text":157,"correct":26},"不限",{"id":159,"libraryId":5,"type":99,"typeLabel":100,"stem":160,"options":161,"answer":31,"analysis":37},932610,"下列说法中，错误的是（ ）。",[162,164,166,168],{"key":20,"text":163,"correct":22},"储存甲、乙类火灾危险性物品的储藏间严禁附设在民用建筑内",{"key":24,"text":165,"correct":22},"销售甲、乙类火灾危险性物品的商店严禁附设在民用建筑内",{"key":28,"text":167,"correct":22},"民用建筑内可设置满足使用功能的附属库房",{"key":31,"text":169,"correct":26},"民用建筑内可设置满足使用功能的附属生产车间",{"id":171,"libraryId":5,"type":99,"typeLabel":100,"stem":172,"options":173,"answer":24,"analysis":37},932611,"某印刷企业在厂区内新建一座多层印刷厂房，耐火等级为二级，则该厂房与变压器装油量为40t的室外变配电站之间的防火间距不应小于（ ）m。",[174,176,177,178],{"key":20,"text":175,"correct":22},"12",{"key":24,"text":140,"correct":26},{"key":28,"text":142,"correct":22},{"key":31,"text":144,"correct":22},{"id":180,"libraryId":5,"type":99,"typeLabel":100,"stem":181,"options":182,"answer":28,"analysis":37},932612,"某27层综合办公楼，层高4m，附近新建一座耐火等级为一级的大型高层酒店，该酒店与综合办公楼相邻一侧外墙全部设成不开设门、窗、洞口的防火墙，顶部无天窗且屋顶耐火极限不低于1．0h，则该酒店与综合楼之间的防火间距（ ）。",[183,185,187,189],{"key":20,"text":184,"correct":22},"不应小于3．5m",{"key":24,"text":186,"correct":22},"不应小于4m",{"key":28,"text":188,"correct":26},"不应小于13m",{"key":31,"text":157,"correct":22},{"id":191,"libraryId":5,"type":99,"typeLabel":100,"stem":192,"options":193,"answer":31,"analysis":37},932613,"某建筑高度为28m的肿瘤医院主楼，一级耐火等级，地上6层，地下2层，主楼内设有门诊房、住院部和药房等，下列说法中错误的是（ ）。",[194,196,198,200],{"key":20,"text":195,"correct":22},"该医院主楼的住院部分不应设置在地下楼层",{"key":24,"text":197,"correct":22},"该医院主楼的疏散楼梯间应采用防烟楼梯间",{"key":28,"text":199,"correct":22},"疏散走道在防火分区处设置的防火门应采用常开甲级防火门",{"key":31,"text":201,"correct":26},"病房之间的隔墙应采用耐火极限不低于2．50h的防火隔墙",{"id":203,"libraryId":5,"type":99,"typeLabel":100,"stem":204,"options":205,"answer":31,"analysis":37},932614,"某商场地上6层，建筑高度为27m，采用一级耐火等级，首层为服装商场，二至三层为电影院，四层至六层为游戏厅和KTV，下列关于电影院防火设计的说法中，错误的是（ ）。",[206,208,210,212],{"key":20,"text":207,"correct":22},"该电影院应采用耐火等级不低于2．00h的防火隔墙和甲级防火门与其他区域分隔",{"key":24,"text":209,"correct":22},"该电影院应设置火灾自动报警系统和自动喷水灭火系统",{"key":28,"text":211,"correct":22},"该电影院至少应设置1个独立的安全出口和疏散楼梯",{"key":31,"text":213,"correct":26},"该电影院每个观众厅的建筑面积不宜大于400m2",{"id":215,"libraryId":5,"type":99,"typeLabel":100,"stem":216,"options":217,"answer":24,"analysis":37},932615,"下列有关桑拿房防火设计的说法中，正确的是（ ）。",[218,220,222,224],{"key":20,"text":219,"correct":22},"桑拿房不应布置在地下楼层",{"key":24,"text":221,"correct":26},"桑拿房不宜在袋形走道的两侧",{"key":28,"text":223,"correct":22},"桑拿房每个厅、室的建筑面积不应大于200m2",{"key":31,"text":225,"correct":22},"桑拿房不宜布置在靠外墙部位",{"id":227,"libraryId":5,"type":99,"typeLabel":100,"stem":228,"options":229,"answer":31,"analysis":37},932616,"下列关于电影院防火设计的说法，不正确的是（ ）。",[230,232,234,236],{"key":20,"text":231,"correct":22},"电影院设置在民用建筑内，与其他区域应采用耐火极限2．00h的防火隔墙和甲级防火门分隔",{"key":24,"text":233,"correct":22},"电影院设置在民用建筑内时，宜布置在一、二级耐火等级建筑内首层、二层和三层",{"key":28,"text":235,"correct":22},"电影院设置在民用建筑内时，应设置至少1个独立的安全出口和疏散楼梯",{"key":31,"text":237,"correct":26},"电影院不应布置在建筑地下二层及以下楼层",{"id":239,"libraryId":5,"type":99,"typeLabel":100,"stem":240,"options":241,"answer":31,"analysis":37},932617,"某单层油浸变压器室，建筑面积400m2，柱的耐火极限为2．00h，与建筑高度为32m住宅之间的防火间距不应低于（ ）m。",[242,244,245,246],{"key":20,"text":243,"correct":22},"10",{"key":24,"text":175,"correct":22},{"key":28,"text":142,"correct":22},{"key":31,"text":140,"correct":26},{"id":248,"libraryId":5,"type":99,"typeLabel":100,"stem":249,"options":250,"answer":28,"analysis":37},932618,"下列有关燃油锅炉房的说法中，错误的是（ ）。",[251,253,255,257],{"key":20,"text":252,"correct":22},"常（负）压燃油锅炉房可设置在地下二层",{"key":24,"text":254,"correct":22},"燃油锅炉房与其储油间之间应采用耐火极限不低于3．00h的防火隔墙分隔",{"key":28,"text":256,"correct":26},"燃油锅炉房内设置储油间时，其总储存量不应大于5m3",{"key":31,"text":258,"correct":22},"燃油锅炉房不应与其他设备用房共用通风系统",{"id":260,"libraryId":5,"type":99,"typeLabel":100,"stem":261,"options":262,"answer":20,"analysis":37},932619,"某耐火等级为一级的地下商场，总建筑面积为6000m2，其中1000m2设置为网吧，其余为超市。该商场全部设置自动喷水灭火系统和火灾自动报警系统保护，且装修材料全部为不燃材料，则该网吧的每个厅、室的建筑面积不应大于（ ）m2。",[263,265,267,269],{"key":20,"text":264,"correct":26},"200",{"key":24,"text":266,"correct":22},"500",{"key":28,"text":268,"correct":22},"1000",{"key":31,"text":270,"correct":22},"2000",{"id":272,"libraryId":5,"type":99,"typeLabel":100,"stem":273,"options":274,"answer":31,"analysis":37},932620,"下列关于儿童活动场所布置的说法，错误的是（ ）。",[275,277,279,281],{"key":20,"text":276,"correct":22},"托儿所、幼儿园的儿童用房和儿童游乐厅等儿童活动场所宜设置在独立的建筑内，且不应设置在地下或是半地下",{"key":24,"text":278,"correct":22},"托儿所、幼儿园的儿童用房和儿童游乐厅等儿童活动场所设置在一、二级耐火等级的多层和高层建筑内时，应设置在建筑物的首层或二、三层",{"key":28,"text":280,"correct":22},"托儿所、幼儿园的儿童用房和儿童游乐厅等儿童活动场所设置在三级耐火等级的建筑内时，应设置在首层及二层",{"key":31,"text":282,"correct":26},"托儿所、幼儿园的儿童用房和儿童游乐厅等儿童活动场所设置在四级耐火等级的建筑内时，应当设置在首层及二层，并均宜设置独立的出口",{"id":284,"libraryId":5,"type":99,"typeLabel":100,"stem":285,"options":286,"answer":31,"analysis":37},932621,"某粮食加工厂有一个6层的面粉碾磨厂房，建筑高度为24.8m，与其相邻有一座三级耐火等级的3层丁类厂房，这两个建筑之间的防火间距不应小于（ ）m。",[287,288,289,291],{"key":20,"text":243,"correct":22},{"key":24,"text":175,"correct":22},{"key":28,"text":290,"correct":22},"13",{"key":31,"text":140,"correct":26},{"id":293,"libraryId":5,"type":99,"typeLabel":100,"stem":294,"options":295,"answer":28,"analysis":37},932622,"某桐油制备厂房，耐火等级二级，建筑高度为34m，拟在旁边新建一座耐火等级为二级的成品仓库，建筑高度为12m，屋顶无天窗，耐火极限为1．00h，如该厂房的外墙采用无任何开口的防火墙时，则两座建筑之间的防火间距（ ）。",[296,297,298,299],{"key":20,"text":186,"correct":22},{"key":24,"text":184,"correct":22},{"key":28,"text":157,"correct":26},{"key":31,"text":154,"correct":22},{"id":301,"libraryId":5,"type":99,"typeLabel":100,"stem":302,"options":303,"answer":28,"analysis":37},932623,"某民用建筑，地上12层，首层为商业服务网点，每个分隔单元180m2，二层及以上为住宅，下列关于该建筑防火设计说法，不正确的是（ ）。",[304,306,308,310],{"key":20,"text":305,"correct":22},"住宅与商业服务网点之间应采用耐火极限不低于2．00h且无门、窗、洞口的防火隔墙和1．50h的不燃性楼板完全分隔",{"key":24,"text":307,"correct":22},"住宅部分的疏散楼梯应独立设置",{"key":28,"text":309,"correct":26},"每个分隔单元至少设两个安全出口",{"key":31,"text":311,"correct":22},"每个分隔单元之间应采用耐火极限不低于2．00h且无门、窗、洞口的防火隔墙相互分隔",{"id":313,"libraryId":5,"type":99,"typeLabel":100,"stem":314,"options":315,"answer":24,"analysis":37},932624,"乙类厂房与明火或散发火花地点的防火间距不宜小于（ ）m。",[316,317,319,321],{"key":20,"text":142,"correct":22},{"key":24,"text":318,"correct":26},"30",{"key":28,"text":320,"correct":22},"40",{"key":31,"text":146,"correct":22},{"id":323,"libraryId":5,"type":99,"typeLabel":100,"stem":324,"options":325,"answer":24,"analysis":37},932625,"两座厂房相邻较高一面外墙为防火墙时，其防火间距不限，但对于甲类厂房之间，防火间距不应小于（ ）m。",[326,328,330,332],{"key":20,"text":327,"correct":22},"2",{"key":24,"text":329,"correct":26},"4",{"key":28,"text":331,"correct":22},"5",{"key":31,"text":243,"correct":22},{"id":334,"libraryId":5,"type":99,"typeLabel":100,"stem":335,"options":336,"answer":24,"analysis":37},932626,"两相邻两座民用高层建筑中，其较低一座建筑的耐火等级不低于二级，屋面板的耐火极限不低于1．00h，屋顶无天窗且相邻较低一面外墙为防火墙时，其防火间距不应小于（ ）m。",[337,338,339,340],{"key":20,"text":327,"correct":22},{"key":24,"text":329,"correct":26},{"key":28,"text":331,"correct":22},{"key":31,"text":243,"correct":22},{"id":342,"libraryId":5,"type":99,"typeLabel":100,"stem":343,"options":344,"answer":20,"analysis":37},932627,"下图两个建筑均为单多层，耐火等级二级，下列防火间距符合规范要求的是（）",[345,347,349,351],{"key":20,"text":346,"correct":26},"①不小于10m",{"key":24,"text":348,"correct":22},"②不大于10m",{"key":28,"text":350,"correct":22},"①不小于7.5m",{"key":31,"text":352,"correct":22},"②不大于7.5m",{"id":354,"libraryId":5,"type":99,"typeLabel":100,"stem":355,"options":356,"answer":24,"analysis":37},932628,"天津某危化厂区所在地区的年最小频率风向为西南风，最大频率风向为西北风，该液化石油厂的下列选址位置中，符合防火要求的是（）。",[357,359,361,363],{"key":20,"text":358,"correct":22},"应放在地势较低的位置",{"key":24,"text":360,"correct":26},"放在厂区的西南侧",{"key":28,"text":362,"correct":22},"放在厂区的西北侧",{"key":31,"text":364,"correct":22},"放在厂区的东北侧",{"id":366,"libraryId":5,"type":99,"typeLabel":100,"stem":367,"options":368,"answer":28,"analysis":37},932629,"某家具仓库占地1200㎡，三层，建筑高度12m，耐火等级为二级，西侧有耐火等级二级的一座木器仓库，占地面积300㎡,两层,建筑高度6m，低侧屋顶耐火极限为1h，高侧设防火墙。则两座建筑物的防火间距最小可为（）m。",[369,370,372,373],{"key":20,"text":243,"correct":22},{"key":24,"text":371,"correct":22},"6",{"key":28,"text":157,"correct":26},{"key":31,"text":329,"correct":22},{"id":375,"libraryId":5,"type":99,"typeLabel":100,"stem":376,"options":377,"answer":28,"analysis":37},932630,"某工厂有一座三层真皮大衣生产厂房，高12米。耐火等级为二级，以下关于厂房平面布置的说法中，正确的是（）。",[378,380,382,384],{"key":20,"text":379,"correct":22},"办公室、休息室可设置在厂房内，并采用耐火极限不低于2.0h的防火隔墙和1.0h的楼板与其他部位分隔",{"key":24,"text":381,"correct":22},"在车间内部方便的地方设置员工宿舍",{"key":28,"text":383,"correct":26},"若设置喷漆车间，喷漆车间应设置在三层靠外墙的位置，且采用防火墙与厂房分隔，并设置门斗，门斗的隔墙为耐火极限不低于2.0h的防火隔墙，门采用甲级防火门",{"key":31,"text":385,"correct":22},"该厂房可采用敞开楼梯间或室外楼梯",{"id":387,"libraryId":5,"type":15,"typeLabel":16,"stem":388,"options":389,"answer":82,"analysis":37},932631,"下列关于锅炉房设置的说法，不符合规定的是（ ）。",[390,392,394,396,398],{"key":20,"text":391,"correct":26},"常压燃气锅炉房设置在屋顶，距安全出口的距离为5m",{"key":24,"text":393,"correct":22},"燃煤锅炉房与煤堆场之间的防火间距为7m",{"key":28,"text":395,"correct":26},"采用相对密度（与空气密度的比值）为1的可燃气体为燃料的锅炉房设置在地下二层",{"key":31,"text":397,"correct":26},"地下锅炉房采用耐火极限不低于2．50h的不燃性隔墙和1．50h的不燃性楼板与储油间分隔开",{"key":34,"text":399,"correct":26},"燃油锅炉房内储油间总储存量为4．00m3，与锅炉房分隔的防火墙上开门时，应设置甲级防火门",{"id":401,"libraryId":5,"type":15,"typeLabel":16,"stem":402,"options":403,"answer":414,"analysis":37},932632,"下列设备用房防火分隔说法中，正确的有（ ）。",[404,406,408,410,412],{"key":20,"text":405,"correct":22},"通风空气调节机房和变配电室开向建筑内的门应采用乙级防火门",{"key":24,"text":407,"correct":22},"变压器室之间、变压器室与配电室之间，应设置耐火极限不低于1．50h的防火隔墙",{"key":28,"text":409,"correct":26},"锅炉房、变压器室等与其他部位之间应采用耐火极限不低于2．00h的防火隔墙和不低于1．50h的不燃性楼板分隔",{"key":31,"text":411,"correct":22},"设置在丁、戊类厂房内的通风机房应采用耐火极限不低于2．00h的防火隔墙和不低于1．50h的楼板与其他部位分隔",{"key":34,"text":413,"correct":26},"布置在民用建筑内的柴油发电机房应采用耐火极限不低于2．00h的防火隔墙和不低于1．50h的不燃性楼板与其他部位分隔，门应采用甲级防火门","CE",{"id":416,"libraryId":5,"type":15,"typeLabel":16,"stem":417,"options":418,"answer":429,"analysis":37},932633,"下列关于防火间距的设置中，不满足规范要求的有（ ）。",[419,421,423,425,427],{"key":20,"text":420,"correct":22},"一级氢气站（H=15m）与一级乙烯聚合厂房（H=10m）的防火间距为12m",{"key":24,"text":422,"correct":22},"一级苯合成厂房（H=10m）与三级木工厂房（H=20m）的防火间距为14m",{"key":28,"text":424,"correct":22},"一级甲醇厂房（H=20m）与一级医院（H=30m）的防火间距为55m",{"key":31,"text":426,"correct":26},"三级制砖车间（H=15m）与四级石棉加工车间（H=20m）的防火间距为13m",{"key":34,"text":428,"correct":26},"三级鱼加工车间（H=18m）与公共建筑的防火间距（H=54m）为20m","DE",{"id":431,"libraryId":5,"type":15,"typeLabel":16,"stem":432,"options":433,"answer":96,"analysis":37},932634,"下列选项中，属于防火间距确定原则的是（ ）。",[434,435,437,438,439],{"key":20,"text":43,"correct":26},{"key":24,"text":436,"correct":22},"保持火势",{"key":28,"text":47,"correct":26},{"key":31,"text":45,"correct":26},{"key":34,"text":51,"correct":22},{"id":441,"libraryId":5,"type":15,"typeLabel":16,"stem":442,"options":443,"answer":454,"analysis":37},932635,"下列关于人员密集场所的建筑平面布置的说法正确的有（ ）。",[444,446,448,450,452],{"key":20,"text":445,"correct":22},"高层建筑内的观众厅、会议厅、多功能厅等人员密集场所设在四层时，一个厅、室的安全出口不应少于3个",{"key":24,"text":447,"correct":26},"歌舞娱乐放映游艺场所不应设置在地下二层及二层以下",{"key":28,"text":449,"correct":26},"歌舞娱乐放映游艺场所一个厅、室的出口不应少于两个，当一个厅、室的建筑面积不大于50m2且经常停留人数不超过15人时，可设置一个疏散门",{"key":31,"text":451,"correct":22},"高层建筑内的观众厅、会议厅、多功能厅等人员密集场所设在六层时，一个厅、室的建筑面积不宜超过300m2",{"key":34,"text":453,"correct":26},"电影院、剧场宜设置在独立的建筑内","BCE",{"id":456,"libraryId":5,"type":15,"typeLabel":16,"stem":457,"options":458,"answer":469,"analysis":37},932636,"高层建筑内的观众厅、会议厅、多功能厅等人员密集场所，宜设在（ ）。",[459,461,463,465,467],{"key":20,"text":460,"correct":22},"地下三层",{"key":24,"text":462,"correct":26},"首层",{"key":28,"text":464,"correct":26},"二层",{"key":31,"text":466,"correct":26},"三层",{"key":34,"text":468,"correct":22},"四层","BCD",{"id":471,"libraryId":5,"type":99,"typeLabel":100,"stem":472,"options":473,"answer":31,"analysis":37},932637,"某L型建筑，地上11层，1至3层为商场，左侧高层为住宅，建筑高度为32m；右侧均为3层商场，建筑高度为15m。下列关于该建筑防火设计的说法中，错误的是（ ）。",[474,476,478,480],{"key":20,"text":475,"correct":22},"商场与住宅之间的墙体应采用无门、窗、洞口的防火墙",{"key":24,"text":477,"correct":22},"商场部分的防火分区可按单、多层公共建筑进行设计",{"key":28,"text":479,"correct":22},"该建筑商场与住宅之间楼板的耐火极限不应低于2.00h",{"key":31,"text":481,"correct":26},"该建筑的耐火等级不应低于一级",{"id":483,"libraryId":5,"type":99,"typeLabel":100,"stem":484,"options":485,"answer":24,"analysis":37},932638,"下列关于厂房防火分区的说法，不正确的是（ ）。",[486,488,490,492],{"key":20,"text":487,"correct":22},"厂房内使用人数为8人的操作平台，其面积可不计入所在防火分区的建筑面积内",{"key":24,"text":489,"correct":26},"防火分区之间应采用防火墙分隔，当设置防火墙确有困难时，可采用防火卷帘或防火分隔水幕分隔",{"key":28,"text":491,"correct":22},"设置自动灭火系统的丁、戊类的地上厂房，每个防火分区的最大允许建筑面积不限",{"key":31,"text":493,"correct":22},"二级耐火等级的多层造纸生产联合厂房，每个防火分区的最大允许建筑面积可按规定增加1．5倍",{"id":495,"libraryId":5,"type":99,"typeLabel":100,"stem":496,"options":497,"answer":28,"analysis":37},932639,"某新建三级耐火等级的蒸汽机车库，最多允许层数为（ ）层。",[498,500,501,503],{"key":20,"text":499,"correct":22},"1",{"key":24,"text":327,"correct":22},{"key":28,"text":502,"correct":26},"3",{"key":31,"text":329,"correct":22},{"id":505,"libraryId":5,"type":99,"typeLabel":100,"stem":506,"options":507,"answer":24,"analysis":37},932640,"一级耐火等级的油浸变压器室，当设置在民用建筑的地下一层不考虑自喷时，每个防火分区的最大允许建筑面积为（ ）m2。",[508,509,510,512],{"key":20,"text":266,"correct":22},{"key":24,"text":268,"correct":26},{"key":28,"text":511,"correct":22},"1500",{"key":31,"text":270,"correct":22},{"id":514,"libraryId":5,"type":99,"typeLabel":100,"stem":515,"options":516,"answer":20,"analysis":37},932641,"下列关于仓库防火分区划分的说法，正确的是（ ）。",[517,519,521,523],{"key":20,"text":518,"correct":26},"独立建造的二级耐火等级电石仓库，每座仓库的最大允许占地面积和每个防火分区的最大允许建筑面积可在规定的基础上增加1．0倍",{"key":24,"text":520,"correct":22},"甲、乙、丙类仓库不应设置在地下或半地下",{"key":28,"text":522,"correct":22},"甲、乙类仓库防火分区之间必须采用不开设门、窗、洞口的防火墙，丙、丁、戊类仓库可采用防火卷帘或防火分隔水幕分隔",{"key":31,"text":524,"correct":22},"仓库内设置自动灭火系统时，包括冷库的防火分区在内，每个防火分区的最大允许建筑面积可按规定增加1．0倍",{"id":526,"libraryId":5,"type":99,"typeLabel":100,"stem":527,"options":528,"answer":20,"analysis":37},932642,"某独立建造的二级耐火等级造纸厂成品库房，地上3层，层高5m，每层建筑面积为2400m2，该仓库每层至少应设（ ）个防火分区。",[529,530,531,532],{"key":20,"text":499,"correct":26},{"key":24,"text":327,"correct":22},{"key":28,"text":502,"correct":22},{"key":31,"text":329,"correct":22},{"id":534,"libraryId":5,"type":99,"typeLabel":100,"stem":535,"options":536,"answer":31,"analysis":37},932643,"下列关于厂房建筑层数的说法，不正确的是（ ）。",[537,539,541,543],{"key":20,"text":538,"correct":22},"二级耐火等级的空分厂房最多允许层数为6层",{"key":24,"text":540,"correct":22},"三级耐火等级的制砖厂可以设置3层",{"key":28,"text":542,"correct":22},"一级耐火等级的白酒勾兑车间宜设置成单层",{"key":31,"text":544,"correct":26},"二级耐火等级的桐油制备厂房不能设地下、半地下室",{"id":546,"libraryId":5,"type":99,"typeLabel":100,"stem":547,"options":548,"answer":31,"analysis":37},932644,"某建筑高度62m的综合楼，设有裙房，裙房与高层建筑主体之间采用防火墙分隔时，裙房的防火分区最大允许建筑面积为（ ）m2。",[549,550,552,554],{"key":20,"text":511,"correct":22},{"key":24,"text":551,"correct":22},"2500",{"key":28,"text":553,"correct":22},"3000",{"key":31,"text":555,"correct":26},"5000",{"id":557,"libraryId":5,"type":99,"typeLabel":100,"stem":558,"options":559,"answer":31,"analysis":37},932645,"某二级耐火等级商场，地上3层，地下1层，每层建筑面积均为6000m2，地下一层为超市和设备用房，则该设备用房的防火分区最大允许建筑面积不应大于（ ）m2。",[560,561,562,563],{"key":20,"text":266,"correct":22},{"key":24,"text":268,"correct":22},{"key":28,"text":511,"correct":22},{"key":31,"text":270,"correct":26},{"id":565,"libraryId":5,"type":99,"typeLabel":100,"stem":566,"options":567,"answer":20,"analysis":37},932646,"对于地下展览厅，当建筑内设置自动灭火系统时，其防火分区最大允许建筑面积可增加（ ）m2。",[568,569,570,571],{"key":20,"text":266,"correct":26},{"key":24,"text":268,"correct":22},{"key":28,"text":511,"correct":22},{"key":31,"text":270,"correct":22},{"id":573,"libraryId":5,"type":99,"typeLabel":100,"stem":574,"options":575,"answer":28,"analysis":37},932647,"某职工公寓，每层建筑面积为6000m2，室外地坪标高为-0．300m，建筑平屋面面层标高为23．6m，女儿墙顶部标高为25．6m，建筑采用耐火极限为1．00h的不燃性楼板和0．15h的难燃性吊顶，则该建筑每层应划分（ ）个防火分区。",[576,577,578,579],{"key":20,"text":327,"correct":22},{"key":24,"text":502,"correct":22},{"key":28,"text":331,"correct":26},{"key":31,"text":371,"correct":22},{"id":581,"libraryId":5,"type":99,"typeLabel":100,"stem":582,"options":583,"answer":24,"analysis":37},932648,"某商业综合楼，地上8层，每层建筑面积12000m2，一至三层为商场，每层层高6．2m，四层到八层为健身房、KTV、餐饮等场所，层高为5．8m，按照国家标准设置相应的消防设施，该综合楼装修材料全部采用不燃材料，首层商场部分至少应划分（ ）个防火分区。",[584,585,586,587],{"key":20,"text":327,"correct":22},{"key":24,"text":502,"correct":26},{"key":28,"text":329,"correct":22},{"key":31,"text":371,"correct":22},{"id":589,"libraryId":5,"type":99,"typeLabel":100,"stem":590,"options":591,"answer":31,"analysis":37},932649,"某二级耐火等级的住宅建筑，建筑高度27m，当设置自动灭火系统时，每个防火分区的最大允许建筑面积为（ ）m2。",[592,593,595,596],{"key":20,"text":511,"correct":22},{"key":24,"text":594,"correct":22},"2400",{"key":28,"text":553,"correct":22},{"key":31,"text":555,"correct":26},[598,601,604,607,610,613],{"id":99,"name":599,"category":7,"favorite":600},"领导干部任职前廉政法规知识测试题",92,{"id":602,"name":603,"category":7,"favorite":99},595,"建筑结构与设备",{"id":605,"name":606,"category":7,"favorite":99},715,"招标采购专业知识与法律法规",{"id":608,"name":609,"category":7,"favorite":99},848,"市政方向-通用基础",{"id":611,"name":612,"category":7,"favorite":8},534,"BIM工程师",{"id":614,"name":612,"category":7,"favorite":8},535]