[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-18":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":625},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,18,50,2960,[13,34,46,58,70,82,94,104,116,128,140,152,164,176,188,200,212,221,233,245,257,269,277,289,301,310,322,334,346,358,370,378,390,402,413,423,435,447,459,469,481,491,509,524,539,554,567,580,595,610],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":24,"analysis":33},932550,1,"单选题","下列关于商店营业厅平面布置的说法中，错误的是（ ）。",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","商店营业厅可设置在一、二级耐火等级的地上建筑的任一层",false,{"key":24,"text":25,"correct":26},"B","商店营业厅不应设置在地下三层及以下或室内地面与室外出入口地坪高差大于10m的地下楼层",true,{"key":28,"text":29,"correct":22},"C","商店营业厅设置在三级耐火等级的民用建筑内时，可设置在首层或二层",{"key":31,"text":32,"correct":22},"D","设置在地下或半地下的商店营业厅，当设置自动喷水灭火系统时，也不应经营、储存和展示甲、乙类火灾危险性物品","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":28,"analysis":33},932551,"下列关于儿童游乐厅平面布置的说法中，正确的是（ ）。",[38,40,42,44],{"key":20,"text":39,"correct":22},"设置在一、二级耐火等级的建筑内时，不应布置在三层及三层以上楼层",{"key":24,"text":41,"correct":22},"设置在耐火等级为一级的多层建筑内时，应设置2个及以上独立的安全出口和疏散楼梯",{"key":28,"text":43,"correct":26},"设置在建筑内的儿童游乐厅应采用耐火极限不低于2．00h的防火隔墙和1．00h的楼板与其他场所或部位分隔",{"key":31,"text":45,"correct":22},"儿童游乐厅与其他场所或部位分隔的隔墙上确需设置门、窗时，应采用甲级防火门、窗",{"id":47,"libraryId":5,"type":15,"typeLabel":16,"stem":48,"options":49,"answer":31,"analysis":33},932552,"下列关于老年人照料设施的说法中，错误的是（ ）。",[50,52,54,56],{"key":20,"text":51,"correct":22},"老年人照料设施宜独立设置",{"key":24,"text":53,"correct":22},"老年人照料设施与其他建筑上、下组合时，老年人照料设施宜设置在建筑的下部",{"key":28,"text":55,"correct":22},"采用一级耐火等级且独立建造的老年人照料设施，其建筑高度不应大于54m",{"key":31,"text":57,"correct":26},"独立建造的老年人照料设施，当采用三级耐火等级时，应为单层",{"id":59,"libraryId":5,"type":15,"typeLabel":16,"stem":60,"options":61,"answer":31,"analysis":33},932553,"老年人照料设施中的老年人公共活动用房指用于老年人集中休闲、娱乐、健身等用途的房间，如公共休息室、阅览室、棋牌室、书画室、健身房等。下列老年人公共活动用房中，可布置在地下一层或地上四层及以上的是（ ）。",[62,64,66,68],{"key":20,"text":63,"correct":22},"每间用房的建筑面积为300m2且使用人数为25人",{"key":24,"text":65,"correct":22},"每间用房的建筑面积为240m2且使用人数为20人",{"key":28,"text":67,"correct":22},"每间用房的建筑面积为150m2且使用人数为35人",{"key":31,"text":69,"correct":26},"每间用房的建筑面积为200m2且使用人数为30人",{"id":71,"libraryId":5,"type":15,"typeLabel":16,"stem":72,"options":73,"answer":28,"analysis":33},932554,"两座耐火等级为二级的丙类固体多层仓库，占地面积均为6500m2，当相邻较高一面外墙为无门、窗、洞口的防火墙时，两座仓库之间的间距（ ）。",[74,76,78,80],{"key":20,"text":75,"correct":22},"不应小于4m",{"key":24,"text":77,"correct":22},"不应小于6m",{"key":28,"text":79,"correct":26},"不应小于10m",{"key":31,"text":81,"correct":22},"不限",{"id":83,"libraryId":5,"type":15,"typeLabel":16,"stem":84,"options":85,"answer":20,"analysis":33},932555,"某高层综合楼的裙房与另一座高层商场裙房之间的防火间距不应小于（ ）m。",[86,88,90,92],{"key":20,"text":87,"correct":26},"6",{"key":24,"text":89,"correct":22},"7",{"key":28,"text":91,"correct":22},"9",{"key":31,"text":93,"correct":22},"13",{"id":95,"libraryId":5,"type":15,"typeLabel":16,"stem":96,"options":97,"answer":31,"analysis":33},932556,"某高层住宅小区，住宅楼耐火等级为二级，为节省土地资源，开发商将相邻高度相同的住宅楼之间的墙均设为防火墙，屋顶耐火极限均设为1．50h，则两座住宅建筑之间的防火间距（ ）。",[98,100,102,103],{"key":20,"text":99,"correct":22},"不应小于13m",{"key":24,"text":101,"correct":22},"不应小于3．5m",{"key":28,"text":75,"correct":22},{"key":31,"text":81,"correct":26},{"id":105,"libraryId":5,"type":15,"typeLabel":16,"stem":106,"options":107,"answer":28,"analysis":33},932557,"下列关于厂房防火间距的说法，不正确的是（ ）。",[108,110,112,114],{"key":20,"text":109,"correct":22},"总容量为15m3的丙类液体储罐，当直埋于厂房外墙外，且面向储罐一面4．0m范围内的外墙为防火墙时，其防火间距不限",{"key":24,"text":111,"correct":22},"甲类厂房与重要公共建筑的防火间距不应小于50m",{"key":28,"text":113,"correct":26},"为厂房服务而单独设置的生活用房应按民用建筑确定，与所属厂房的防火间距不应小于6m",{"key":31,"text":115,"correct":22},"耐火等级低于四级的既有厂房，其耐火等级可按四级确定",{"id":117,"libraryId":5,"type":15,"typeLabel":16,"stem":118,"options":119,"answer":28,"analysis":33},932558,"下列建筑中，当为三级耐火等级时，其建筑层数可采用3层的是（ ）。",[120,122,124,126],{"key":20,"text":121,"correct":22},"教学楼",{"key":24,"text":123,"correct":22},"食堂",{"key":28,"text":125,"correct":26},"办公楼",{"key":31,"text":127,"correct":22},"菜市场",{"id":129,"libraryId":5,"type":15,"typeLabel":16,"stem":130,"options":131,"answer":24,"analysis":33},932559,"下列有关会议厅、多功能厅等人员密集场所防火设计的说法中，正确的是（ ）。",[132,134,136,138],{"key":20,"text":133,"correct":22},"会议室、多功能厅等人员密集场所可设置在地下或半地下任意楼层",{"key":24,"text":135,"correct":26},"会议室、多功能厅等人员密集场所可布置在三级耐火等级的首层或二层",{"key":28,"text":137,"correct":22},"会议室、多功能厅等人员密集场所布置在一、二级耐火等级建筑内时，应设置火灾自动报警系统和自动喷水灭火系统等自动灭火系统",{"key":31,"text":139,"correct":22},"会议室、多功能厅等人员密集场所布置在一、二级耐火等级建筑内的四层及以上楼层时，当其建筑面积不大于400m2时，可设置1个疏散门",{"id":141,"libraryId":5,"type":15,"typeLabel":16,"stem":142,"options":143,"answer":20,"analysis":33},932560,"下列关于设备用房的说法，不正确的是（ ）。",[144,146,148,150],{"key":20,"text":145,"correct":26},"常压燃气锅炉房设置在屋顶，距安全出口距离为4m",{"key":24,"text":147,"correct":22},"单独建造的变压器室耐火等级为二级",{"key":28,"text":149,"correct":22},"燃油锅炉房的储油间采用3．00h的防火隔墙与锅炉间分隔",{"key":31,"text":151,"correct":22},"柴油发电机房布置在建筑首层",{"id":153,"libraryId":5,"type":15,"typeLabel":16,"stem":154,"options":155,"answer":24,"analysis":33},932561,"三级耐火等级的商店，建筑层数不应超过（ ）层。",[156,158,160,162],{"key":20,"text":157,"correct":22},"1",{"key":24,"text":159,"correct":26},"2",{"key":28,"text":161,"correct":22},"3",{"key":31,"text":163,"correct":22},"4",{"id":165,"libraryId":5,"type":15,"typeLabel":16,"stem":166,"options":167,"answer":31,"analysis":33},932562,"某高层建筑的第六层为多功能厅，下列关于该多功能厅的防火设计要求的说法，不正确的是（ ）。",[168,170,172,174],{"key":20,"text":169,"correct":22},"多功能厅应设置火灾自动报警系统和自动喷水灭火系统",{"key":24,"text":171,"correct":22},"一个厅、室的疏散门不应少于2个，且建筑面积不宜大于400m2",{"key":28,"text":173,"correct":22},"每个厅、室的建筑面积不宜大于400m2",{"key":31,"text":175,"correct":26},"厅、室之间应采用2．00h的防火隔墙和乙级防火门分隔",{"id":177,"libraryId":5,"type":15,"typeLabel":16,"stem":178,"options":179,"answer":20,"analysis":33},932563,"某高层商场，计划在商场第四层分隔一片区域作为KTV，下列关于该KTV防火设计的说法，错误的是（ ）。",[180,182,184,186],{"key":20,"text":181,"correct":26},"小于50m2厅、室至少设置两个疏散门",{"key":24,"text":183,"correct":22},"KTV与商场相通的门应采用乙级防火门",{"key":28,"text":185,"correct":22},"采用耐火极限为2．00h的防火隔墙与1．00h的不燃性楼板与其他场所分隔",{"key":31,"text":187,"correct":22},"KTV应设置火灾自动报警系统和自动灭火系统",{"id":189,"libraryId":5,"type":15,"typeLabel":16,"stem":190,"options":191,"answer":28,"analysis":33},932564,"某单层樟脑油提炼厂房外贴临建造的办公室应采用耐火极限不低于（ ）与厂房分隔。",[192,194,196,198],{"key":20,"text":193,"correct":22},"3．00h的防火墙",{"key":24,"text":195,"correct":22},"2．50h的防火墙",{"key":28,"text":197,"correct":26},"3．00h的防爆墙",{"key":31,"text":199,"correct":22},"4．00h的防火墙",{"id":201,"libraryId":5,"type":15,"typeLabel":16,"stem":202,"options":203,"answer":20,"analysis":33},932565,"某一级耐火等级的多层木器厂房，首层设有办公室、休息室时应采用（ ）与其他部位分隔。",[204,206,208,210],{"key":20,"text":205,"correct":26},"2．50h的防火隔墙与1．50h的不燃性楼板",{"key":24,"text":207,"correct":22},"3．00h的防火隔墙与0．50h的不燃性楼板",{"key":28,"text":209,"correct":22},"2．50h的防火隔墙与0．50h的不燃性楼板",{"key":31,"text":211,"correct":22},"2．00h的防火隔墙与1．00h的不燃性楼板",{"id":213,"libraryId":5,"type":15,"typeLabel":16,"stem":214,"options":215,"answer":31,"analysis":33},932566,"某耐火等级为一级的多层焦化厂，顶部设有独立房间储存焦油，其储罐容积不应大于（ ）m3。",[216,217,218,219],{"key":20,"text":157,"correct":22},{"key":24,"text":159,"correct":22},{"key":28,"text":163,"correct":22},{"key":31,"text":220,"correct":26},"5",{"id":222,"libraryId":5,"type":15,"typeLabel":16,"stem":223,"options":224,"answer":28,"analysis":33},932567,"下列关于工业建筑平面布置的做法，不符合规定的是（ ）。",[225,227,229,231],{"key":20,"text":226,"correct":22},"单独建造的柴油发电机房设总储量为15m3的柴油中间储罐，平均存储在三个独立房间，房间采用耐火极限为3．00h的防火隔墙与1．50h的不燃性楼板与其他部位分隔，房间门采用甲级防火门",{"key":24,"text":228,"correct":22},"某多层白兰地成品仓库内设有办公室，采用耐火极限为3．00h的防爆墙与1．00h的不燃性楼板分隔，墙上开乙级防火门",{"key":28,"text":230,"correct":26},"某多层金属抛光车间，设有丙类中间仓库，采用耐火极限为3．00h的防火隔墙与1．50h的楼板分隔",{"key":31,"text":232,"correct":22},"某玉米油浸出车间，设乙类中间仓库，采用防火墙和耐火极限不低于1．50h的不燃性楼板分隔",{"id":234,"libraryId":5,"type":15,"typeLabel":16,"stem":235,"options":236,"answer":31,"analysis":33},932568,"某油浸变压器设置在高层商店建筑外的专用房间内，该变压器装油量为20t，下列说法中，正确的是（ ）。",[237,239,241,243],{"key":20,"text":238,"correct":22},"油浸变压器室与商店建筑的防火间距不应小于20m",{"key":24,"text":240,"correct":22},"油浸变压器室与商店建筑的防火间距不应小于30m",{"key":28,"text":242,"correct":22},"油浸变压器室专用房间的耐火等级不应低于一级",{"key":31,"text":244,"correct":26},"油浸变压器室专用房间的耐火等级不应低于二级",{"id":246,"libraryId":5,"type":15,"typeLabel":16,"stem":247,"options":248,"answer":24,"analysis":33},932569,"关于在公共建筑内设置变压器室的做法，错误的是（ ）。",[249,251,253,255],{"key":20,"text":250,"correct":22},"变压器室与配电室之间设置耐火极限为3．00h的防火隔墙",{"key":24,"text":252,"correct":26},"变压器室设置在地下一层的靠中间部位",{"key":28,"text":254,"correct":22},"设置在地下一层的变压器室的疏散门直通疏散楼梯间",{"key":31,"text":256,"correct":22},"变压器室和建筑内其他部分设有自动喷水灭火系统",{"id":258,"libraryId":5,"type":15,"typeLabel":16,"stem":259,"options":260,"answer":31,"analysis":33},932570,"下列有关柴油发电机房防火设计的说法中，错误的是（ ）。",[261,263,265,267],{"key":20,"text":262,"correct":22},"柴油发电机房内设置的储油间，其总储存量不应大于1m3",{"key":24,"text":264,"correct":22},"与建筑内其他部位分隔的门及储油间的门均应设置甲级防火门",{"key":28,"text":266,"correct":22},"柴油发电机房应设置备用照明",{"key":31,"text":268,"correct":26},"当采用七氟丙烷气体灭火系统进行保护时，灭火设计浓度宜采用10％",{"id":270,"libraryId":5,"type":15,"typeLabel":16,"stem":271,"options":272,"answer":24,"analysis":33},932571,"对于四级耐火等级的民用建筑，其最多允许建筑层数为（ ）层。",[273,274,275,276],{"key":20,"text":157,"correct":22},{"key":24,"text":159,"correct":26},{"key":28,"text":161,"correct":22},{"key":31,"text":163,"correct":22},{"id":278,"libraryId":5,"type":15,"typeLabel":16,"stem":279,"options":280,"answer":20,"analysis":33},932572,"某一级耐火等级的商场，地上6层，四层为KTV，设置自动喷水灭火系统、火灾自动报警报警系统保护，则该KTV厅、室的建筑面积不应大于（ ）m2。",[281,283,285,287],{"key":20,"text":282,"correct":26},"200",{"key":24,"text":284,"correct":22},"400",{"key":28,"text":286,"correct":22},"600",{"key":31,"text":288,"correct":22},"800",{"id":290,"libraryId":5,"type":15,"typeLabel":16,"stem":291,"options":292,"answer":31,"analysis":33},932573,"某甲酚厂房的办公室贴邻该厂房建造，办公室与甲酚厂房之间应采用（ ）与其他部位分隔。",[293,295,297,299],{"key":20,"text":294,"correct":22},"耐火极限不低于3．00h的防火墙",{"key":24,"text":296,"correct":22},"耐火极限不低于2．00h的防火隔墙",{"key":28,"text":298,"correct":22},"耐火极限不低于3．00h的防火隔墙",{"key":31,"text":300,"correct":26},"耐火极限不低于3．00h的防爆墙",{"id":302,"libraryId":5,"type":15,"typeLabel":16,"stem":303,"options":304,"answer":28,"analysis":33},932574,"某建筑高度为105m的高级酒店，拟在其正东侧建造一栋建筑高度为60m的写字楼，已知该酒店与写字楼相邻一侧为防火墙，根据《建筑设计防火规范》GB 50016—2014（2018年版）规定，该酒店与写字楼之间的最小防火间距应为（ ）m。",[305,306,308,309],{"key":20,"text":91,"correct":22},{"key":24,"text":307,"correct":22},"10",{"key":28,"text":93,"correct":26},{"key":31,"text":81,"correct":22},{"id":311,"libraryId":5,"type":15,"typeLabel":16,"stem":312,"options":313,"answer":24,"analysis":33},932575,"下列关于建筑防火分类的做法中，错误的是（ ）。",[314,316,318,320],{"key":20,"text":315,"correct":22},"卡拉OK厅各厅室之间采用耐火极限为2．00h的防火墙面和1．5h的不燃性楼板和乙级防火门分隔",{"key":24,"text":317,"correct":26},"锅炉房内的储油间（柴油储量为0．8m3）。采用防火极限为2．50h的防火隔墙和1．50h的不燃性楼板和甲级防火门与其他部位分隔",{"key":28,"text":319,"correct":22},"高层住宅建筑下部设置的商业服务网点，采用耐火极限为3．00h且无门、窗、洞口的防火隔墙和2.00h的不燃性楼板与其他部位分隔",{"key":31,"text":321,"correct":22},"医院病房内相邻护理单元之间采用耐火极限为2．00h的防火隔墙和乙级防火门分隔",{"id":323,"libraryId":5,"type":15,"typeLabel":16,"stem":324,"options":325,"answer":28,"analysis":33},932576,"厂房内严禁设置（ ）。",[326,328,330,332],{"key":20,"text":327,"correct":22},"休息室",{"key":24,"text":329,"correct":22},"办公室",{"key":28,"text":331,"correct":26},"员工宿舍",{"key":31,"text":333,"correct":22},"会议室",{"id":335,"libraryId":5,"type":15,"typeLabel":16,"stem":336,"options":337,"answer":20,"analysis":33},932577,"下列用房通常可以设置在地下室的是（ ）。",[338,340,342,344],{"key":20,"text":339,"correct":26},"游艺厅",{"key":24,"text":341,"correct":22},"医院病房",{"key":28,"text":343,"correct":22},"幼儿园",{"key":31,"text":345,"correct":22},"儿童游乐厅",{"id":347,"libraryId":5,"type":15,"typeLabel":16,"stem":348,"options":349,"answer":28,"analysis":33},932578,"住宅建筑与其他使用功能的建筑合建时，下列防火分隔的说法中，错误的是（ ）。",[350,352,354,356],{"key":20,"text":351,"correct":22},"住宅部分与非住宅部分之间，应采用耐火极限不低于1．50h的不燃性楼板和耐火极限不低于2．00h且无门、窗、洞口的防火隔墙完全分隔",{"key":24,"text":353,"correct":22},"住宅部分与非住宅部分相接处上下层开口之间应设置挑出宽度不小于1．0m、长度不小于开口宽度的防火挑檐",{"key":28,"text":355,"correct":26},"当室内设置自动喷水灭火系统时，上下层开口之间的实体墙高度不应小于0．5m",{"key":31,"text":357,"correct":22},"设置商业服务网点的住宅建筑，居住部分与商业服务网点之间应采用耐火极限不低于1．50h的不燃性楼板和耐火极限不低于2．00h且无门、窗、洞口的防火隔墙完全分隔",{"id":359,"libraryId":5,"type":15,"typeLabel":16,"stem":360,"options":361,"answer":24,"analysis":33},932579,"下列关于建筑选址的说法，不正确的是（ ）。",[362,364,366,368],{"key":20,"text":363,"correct":22},"甲、乙、丙类液体的仓库，宜布置在地势较低的地方",{"key":24,"text":365,"correct":26},"散发可燃蒸气和可燃粉尘的车间、装置宜布置在明火或散发火花地点的全年最小频率下风侧",{"key":28,"text":367,"correct":22},"生产和储存爆炸物品的企业应选择在多面环山、附近没有建筑的地方",{"key":31,"text":369,"correct":22},"生产、储存易燃易爆危险物品的工厂、仓库必须设置在城市的边缘或者相对独立的安全地带",{"id":371,"libraryId":5,"type":15,"typeLabel":16,"stem":372,"options":373,"answer":31,"analysis":33},932580,"某建筑高度为24m的丙类厂房，耐火等级为二级，拟在其旁边新建一座5层难燃铝塑材料加工厂房、建筑高度为25m，难燃铝塑材料加工厂房外墙上的门、窗、洞口均采用甲级防火门、窗，则两座厂房之间的防火间距不应小于（）m。",[374,375,376,377],{"key":20,"text":307,"correct":22},{"key":24,"text":87,"correct":22},{"key":28,"text":93,"correct":22},{"key":31,"text":163,"correct":26},{"id":379,"libraryId":5,"type":15,"typeLabel":16,"stem":380,"options":381,"answer":20,"analysis":33},932581,"某大型化工企业,进行总平面设计,企业消防站的位置设置应便于消防车方便出入的主要道路旁,宜位于生产区全年最小频率风向的（ ）。",[382,384,386,388],{"key":20,"text":383,"correct":26},"下风侧",{"key":24,"text":385,"correct":22},"上风侧",{"key":28,"text":387,"correct":22},"侧风侧",{"key":31,"text":389,"correct":22},"同风侧",{"id":391,"libraryId":5,"type":15,"typeLabel":16,"stem":392,"options":393,"answer":31,"analysis":33},932582,"地下、半地下营业厅、展览厅可以经营、储存和展示下列（ ）物品。",[394,396,398,400],{"key":20,"text":395,"correct":22},"金属罐等原浆散装且酒精度数为 38 度以上的白酒",{"key":24,"text":397,"correct":22},"乒乓球",{"key":28,"text":399,"correct":22},"定型发胶",{"key":31,"text":401,"correct":26},"固体酒精炉",{"id":403,"libraryId":5,"type":15,"typeLabel":16,"stem":404,"options":405,"answer":24,"analysis":33},932583,"下列关于厂房的防火间距说法错误的是（ ）。",[406,408,410,411],{"key":20,"text":407,"correct":22},"乙类厂房与重要公共建筑的防火间距不宜小于50m",{"key":24,"text":409,"correct":26},"两座厂房相邻较高一面外墙为防火墙时，其防火间距不限，但甲类厂房之间不应小于3m",{"key":28,"text":115,"correct":22},{"key":31,"text":412,"correct":22},"发电厂内的主变压器，其油量可按单台确定",{"id":414,"libraryId":5,"type":15,"typeLabel":16,"stem":415,"options":416,"answer":24,"analysis":33},932584,"下列关于防火间距的说法错误的是（ ）。",[417,418,420,422],{"key":20,"text":111,"correct":22},{"key":24,"text":419,"correct":26},"两座仓库的相邻外墙均为防火墙时，防火间距可以减小，但丙类不应小于5m",{"key":28,"text":421,"correct":22},"为丙、丁、戊类厂房服务而单独设置的生活用房应按民用建筑确定，与所属厂房的防火间距不应小于6m",{"key":31,"text":115,"correct":22},{"id":424,"libraryId":5,"type":15,"typeLabel":16,"stem":425,"options":426,"answer":24,"analysis":33},932585,"下列关于柴油发电机房的布置说法错误的是（ ）。",[427,429,431,433],{"key":20,"text":428,"correct":22},"布置在办公楼的地下一层",{"key":24,"text":430,"correct":26},"布置在地下商场旁边",{"key":28,"text":432,"correct":22},"布置在医院的地下二层",{"key":31,"text":434,"correct":22},"机房内设置储油间时，其总储存量不应大于1m3",{"id":436,"libraryId":5,"type":15,"typeLabel":16,"stem":437,"options":438,"answer":24,"analysis":33},932586,"下列符合建筑平面布置规范要求的是（ ）。",[439,441,443,445],{"key":20,"text":440,"correct":22},"锅炉房、变压器室与其他部位之间采用耐火极限为2．00h的防火隔墙和1．00h的不燃性楼板隔开",{"key":24,"text":442,"correct":26},"单独建造的消防控制室其耐火等级为二级",{"key":28,"text":444,"correct":22},"柴油发电机房布置在某商场的地下一层",{"key":31,"text":446,"correct":22},"电影院观影厅布置在某商场6层，建筑面积为400m2并设置了1个疏散门",{"id":448,"libraryId":5,"type":15,"typeLabel":16,"stem":449,"options":450,"answer":20,"analysis":33},932587,"甲类厂房与明火或散发火花地点的防火间距最小应为（ ）。",[451,453,455,457],{"key":20,"text":452,"correct":26},"30m",{"key":24,"text":454,"correct":22},"40m",{"key":28,"text":456,"correct":22},"50m",{"key":31,"text":458,"correct":22},"60m",{"id":460,"libraryId":5,"type":15,"typeLabel":16,"stem":461,"options":462,"answer":24,"analysis":33},932588,"厂房内设置不超过一昼夜需要量的甲、乙类中间仓库时，中间仓库应靠外墙布置，并应采用防火墙和耐火极限不低于（ ）h的不燃烧性楼板与其他部分隔开。",[463,464,466,468],{"key":20,"text":157,"correct":22},{"key":24,"text":465,"correct":26},"1． 5",{"key":28,"text":467,"correct":22},"2．5",{"key":31,"text":159,"correct":22},{"id":470,"libraryId":5,"type":15,"typeLabel":16,"stem":471,"options":472,"answer":28,"analysis":33},932589,"下列建筑选址符合规范的是（ ）。",[473,475,477,479],{"key":20,"text":474,"correct":22},"某烟花爆竹仓库位于某小区地下室",{"key":24,"text":476,"correct":22},"乙炔站布置在河流下游盆地水源充足的地方",{"key":28,"text":478,"correct":26},"某白酒加工厂布置在该地区全年最小频率风向的上风侧",{"key":31,"text":480,"correct":22},"液化石油气储罐区宜布置在本单位或本地区全年最小频率风向的下风侧",{"id":482,"libraryId":5,"type":15,"typeLabel":16,"stem":483,"options":484,"answer":31,"analysis":33},932590,"根据《建筑设计防火规范》GB50016—2014（2018年版）规定，下列关于厂房防火间距说法错误的是（）。",[485,487,488,489],{"key":20,"text":486,"correct":22},"乙类厂房与二类高层民用建筑的防火间距不应小于50m",{"key":24,"text":111,"correct":22},{"key":28,"text":115,"correct":22},{"key":31,"text":490,"correct":26},"两座厂房相邻较高一面外墙为防火墙，其防火间距不限，但甲类厂房之间不应小于5m",{"id":492,"libraryId":5,"type":493,"typeLabel":494,"stem":495,"options":496,"answer":508,"analysis":33},932591,2,"多选题","某二级耐火等级的多层大豆油精炼车间，其周边布置有多座二级耐火等级建筑，下列关于该车间与周边建筑物防火间距的做法中，正确的有（ ）。",[497,499,501,503,505],{"key":20,"text":498,"correct":26},"与油浸变压器室（建筑高度7m）的防火间距为10m",{"key":24,"text":500,"correct":22},"与陶瓷制品烘干厂（建筑高度26m）的防火间距为12m",{"key":28,"text":502,"correct":26},"与大豆油原料仓库（建筑高度15m）的防火间距为13m",{"key":31,"text":504,"correct":26},"与大豆油成品仓库（建筑高度21m）的防火间距为16m",{"key":506,"text":507,"correct":22},"E","与大豆油浸出车间（建筑高度6m）的防火间距为10m","ACD",{"id":510,"libraryId":5,"type":493,"typeLabel":494,"stem":511,"options":512,"answer":523,"analysis":33},932592,"下列场所中，附设在建筑内时，不应布置在地下二层的有（ ）。",[513,515,517,519,521],{"key":20,"text":514,"correct":26},"网吧",{"key":24,"text":516,"correct":22},"礼堂",{"key":28,"text":518,"correct":22},"电影院",{"key":31,"text":520,"correct":22},"多功能厅",{"key":506,"text":522,"correct":26},"录像放映厅","AE",{"id":525,"libraryId":5,"type":493,"typeLabel":494,"stem":526,"options":527,"answer":538,"analysis":33},932593,"下列设备用房，设置在民用建筑地下或半地下时，疏散门应直通室外或安全出口的有（ ）。",[528,530,532,534,536],{"key":20,"text":529,"correct":22},"柴油发电机房",{"key":24,"text":531,"correct":26},"消防控制室",{"key":28,"text":533,"correct":26},"消防水泵房",{"key":31,"text":535,"correct":26},"燃油锅炉房",{"key":506,"text":537,"correct":26},"油浸变压器室","BCDE",{"id":540,"libraryId":5,"type":493,"typeLabel":494,"stem":541,"options":542,"answer":553,"analysis":33},932594,"某经营松香油、乳香油、香蕉水等物品的商店，设置在一级耐火等级的建筑内时，可布置的楼层有（ ）。",[543,545,547,549,551],{"key":20,"text":544,"correct":22},"地下一层",{"key":24,"text":546,"correct":22},"地下二层",{"key":28,"text":548,"correct":26},"建筑首层",{"key":31,"text":550,"correct":26},"建筑二层",{"key":506,"text":552,"correct":22},"地下三层","CD",{"id":555,"libraryId":5,"type":493,"typeLabel":494,"stem":556,"options":557,"answer":566,"analysis":33},932595,"下列场所设置在建筑内时，可以布置在地下二层的有（ ）。",[558,560,561,563,565],{"key":20,"text":559,"correct":22},"医院住院部",{"key":24,"text":343,"correct":22},{"key":28,"text":562,"correct":22},"KTV",{"key":31,"text":564,"correct":26},"商店营业厅",{"key":506,"text":529,"correct":26},"DE",{"id":568,"libraryId":5,"type":493,"typeLabel":494,"stem":569,"options":570,"answer":579,"analysis":33},932596,"下列场所，布置在高层民用建筑内时，应设置独立安全出口和疏散楼梯的有（）。",[571,573,574,575,577],{"key":20,"text":572,"correct":22},"展览厅",{"key":24,"text":520,"correct":22},{"key":28,"text":345,"correct":26},{"key":31,"text":576,"correct":22},"录像厅",{"key":506,"text":578,"correct":26},"幼儿园的儿童用房","CE",{"id":581,"libraryId":5,"type":493,"typeLabel":494,"stem":582,"options":583,"answer":594,"analysis":33},932597,"下列关于防火间距确定原则的说法，错误的是（ ）。",[584,586,588,590,592],{"key":20,"text":585,"correct":26},"防火间距应按相邻建筑物外墙的最近距离计算，如外墙有凸出的不燃构件，则应从其凸出部分外缘算起",{"key":24,"text":587,"correct":26},"变压器之间的防火间距应为相邻变压器内壁的最近水平距离",{"key":28,"text":589,"correct":26},"储罐之间的防火间距应为相邻两储罐内壁的最近水平距离",{"key":31,"text":591,"correct":22},"堆场之间的防火间距应为两堆场中相邻堆垛外缘的最近水平距离",{"key":506,"text":593,"correct":22},"建筑物与堆场的防火间距，应为建筑外墙至堆场中相邻堆垛外缘的最近水平距离","ABC",{"id":596,"libraryId":5,"type":493,"typeLabel":494,"stem":597,"options":598,"answer":609,"analysis":33},932598,"某地上5层商场，耐火等级为一级，地下2层，每层建筑面积3400m2，首层为商场，二层及以上使用性质为电影院、KTV、网吧、剧场等场所，地下为汽车库，部分为设备间，下列做法中，不正确的是（）。",[599,601,603,605,607],{"key":20,"text":600,"correct":22},"第二层的电影院设置8个观众厅，每个厅建筑面积为105-420m2不等，每个厅设两个疏散门",{"key":24,"text":602,"correct":26},"第四层的KTV靠外墙设置，采用耐火极限为2．00h的防火隔墙和1．00h的不燃性楼板划分为多个建筑面积不大于120m2的房间",{"key":28,"text":604,"correct":26},"柴油发电机房设置在地下一层，采用耐火极限为3．00h的防火隔墙和1．50h的楼板与其他部位分隔",{"key":31,"text":606,"correct":22},"第三层的网吧采用耐火极限为2．50h的防火隔墙和1．50h的不燃性楼板与其他场所分隔，连通处设置乙级防火门",{"key":506,"text":608,"correct":26},"第五层的剧场，舞台与观众厅之间的隔墙采用耐火极限为2．00h的防火隔墙","BCE",{"id":611,"libraryId":5,"type":493,"typeLabel":494,"stem":612,"options":613,"answer":624,"analysis":33},932599,"某医院新建大楼，地上8层，地下1层，层高3m，每层建筑面积1600m2，首层为接待大厅，二层为手术室，三层及以上为病房，二层以上每层设有避难间，下列关于该建筑防火设计的说法，正确的是（）。",[614,616,618,620,622],{"key":20,"text":615,"correct":22},"相邻护理单元之间应采用耐火极限不低于2．00h的防火隔墙分隔，隔墙上的门应采用甲级防火门，设置在走道上的防火门应采用常开防火门",{"key":24,"text":617,"correct":26},"手术室与其他部位之间应采用耐火极限不低于2．00h的防火隔墙和1．00h的楼板与其他场所或部位分隔，墙上设置的门、窗应应采用乙级防火门、窗",{"key":28,"text":619,"correct":22},"避难间与其他部位之间应采用耐火极限为2．00h的防火隔墙和乙级防火门与其他部位分隔",{"key":31,"text":621,"correct":22},"避难间应设置独立的机械排烟设施，外窗应采用乙级防火窗",{"key":506,"text":623,"correct":26},"避难间的入口处应设置明显的指示标志","BE",[626,629,632,635,638,641],{"id":15,"name":627,"category":7,"favorite":628},"领导干部任职前廉政法规知识测试题",92,{"id":630,"name":631,"category":7,"favorite":15},595,"建筑结构与设备",{"id":633,"name":634,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":636,"name":637,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":639,"name":640,"category":7,"favorite":8},534,"BIM工程师",{"id":642,"name":640,"category":7,"favorite":8},535]