[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-12":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":642},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,12,50,2960,[13,34,46,64,76,88,100,112,124,136,148,160,172,184,196,211,226,234,246,258,270,282,294,309,321,333,344,356,368,382,397,409,421,433,445,457,468,478,493,508,522,534,546,558,570,582,594,606,618,630],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":20,"analysis":33},932245,1,"单选题","（2018真题）根据现行国家标准《地铁设计规范》(GB50157),下列场所中,可按二级耐火等级设计的是（ ）",[19,23,27,30],{"key":20,"text":21,"correct":22},"A","高架车站",true,{"key":24,"text":25,"correct":26},"B","地下车站疏散楼梯间",false,{"key":28,"text":29,"correct":26},"C","控制中心",{"key":31,"text":32,"correct":26},"D","地下车站风道","",{"id":35,"libraryId":5,"type":15,"typeLabel":16,"stem":36,"options":37,"answer":24,"analysis":33},932246,"（2019年真题）地铁工程中防火隔墙的设置，正确的是（）",[38,40,42,44],{"key":20,"text":39,"correct":26},"隔墙上的窗口应采用固定式甲级防火窗或火灾时能自行关闭的甲级防火窗",{"key":24,"text":41,"correct":22},"隔墙上的窗口应采用固定式乙级防火窗或火灾时能行关闭的乙级防火窗",{"key":28,"text":43,"correct":26},"多线同层站台平行换乘车站的各站台之间的防火隔墙，应延伸至站台有效长",{"key":31,"text":45,"correct":26},"管道穿越防火隔墙处两侧各0.5m范围内的管道保温材料应采用不燃",{"id":47,"libraryId":5,"type":48,"typeLabel":49,"stem":50,"options":51,"answer":63,"analysis":33},932247,2,"多选题","（2019年真题）下列防烟分区划分设计要求中，适用于地铁站厅公共区的有（）",[52,54,56,58,60],{"key":20,"text":53,"correct":22},"防烟分区不应跨越防火分区",{"key":24,"text":55,"correct":26},"防烟分区的最大允许面积与空间净高相关",{"key":28,"text":57,"correct":26},"防烟分区的长边最大允许长度与空间净高相关",{"key":31,"text":59,"correct":26},"当空间高度大于规定值时，防烟分区之间可不设置挡烟设施",{"key":61,"text":62,"correct":22},"E","采用挡烟垂壁或建筑结构划分防烟分区","AE",{"id":65,"libraryId":5,"type":15,"typeLabel":16,"stem":66,"options":67,"answer":24,"analysis":33},932248,"（2019年真题）地铁车站的下列区域中，可设置报刊亭的是（）",[68,70,72,74],{"key":20,"text":69,"correct":26},"站厅付费区",{"key":24,"text":71,"correct":22},"站厅非付费区乘客疏散区外",{"key":28,"text":73,"correct":26},"出入口通道乘客集散区",{"key":31,"text":75,"correct":26},"站台层有人值守的设备管理区外",{"id":77,"libraryId":5,"type":15,"typeLabel":16,"stem":78,"options":79,"answer":28,"analysis":33},932249,"（2019年真题）地铁两条单线载客运营地下区间质检应按规定设置于联络通道，相邻两条联络通道之间的最小水平距离不应大于()",[80,82,84,86],{"key":20,"text":81,"correct":26},"1200m",{"key":24,"text":83,"correct":26},"1000m",{"key":28,"text":85,"correct":22},"600m",{"key":31,"text":87,"correct":26},"500m",{"id":89,"libraryId":5,"type":15,"typeLabel":16,"stem":90,"options":91,"answer":28,"analysis":33},932250,"（2019年真题）某地铁地上车站，建筑高度为18m，站台层与站厅层之间设有建筑面积为100㎡的商场，各层均能满足自然排烟条件。该车站的下列防火设计方案中，错误的是（）。",[92,94,96,98],{"key":20,"text":93,"correct":26},"车站站厅顶棚采用硅酸钙板，墙面采用烤瓷铝板、地面采用硬质PVC塑料地板进行装修，广告灯箱及座椅采用难燃聚氯乙烯塑料",{"key":24,"text":95,"correct":26},"沿车站的一个长边设置消防车道",{"key":28,"text":97,"correct":22},"车站站台至站厅的楼梯穿越商场的部位周围，设置耐火极限3.00h的防火墙分隔，且在商场疏散平台处开设的门洞采用甲级防火门分隔",{"key":31,"text":99,"correct":26},"车站的站厅公共区相邻两个安全出口之间的最小水平距离为20m",{"id":101,"libraryId":5,"type":15,"typeLabel":16,"stem":102,"options":103,"answer":31,"analysis":33},932251,"（2020年真题）地铁车辆基地建筑的上部建有10栋高层住宅建筑，下列说法错误的是（ ）。",[104,106,108,110],{"key":20,"text":105,"correct":26},"车辆基地建筑的承重构件的耐火极限不应低于3.00h",{"key":24,"text":107,"correct":26},"车辆基地建筑的楼板的耐火极限不应低于2.00h",{"key":28,"text":109,"correct":26},"车辆基地与住宅建筑的人员安全出口不应相互借",{"key":31,"text":111,"correct":22},"车辆基地与住宅建筑之间应采用耐火极限不低于2.50h的楼板分隔",{"id":113,"libraryId":5,"type":15,"typeLabel":16,"stem":114,"options":115,"answer":31,"analysis":33},932252,"（2020年真题）关于地铁火灾危险性和特点的说法，错误的是（ ）。",[116,118,120,122],{"key":20,"text":117,"correct":26},"地下区间火灾救援难度大",{"key":24,"text":119,"correct":26},"地铁站内动态火灾隐患多",{"key":28,"text":121,"correct":26},"地铁站内排烟排热难度大",{"key":31,"text":123,"correct":22},"地铁站台公共区火灾蔓延具有跳跃性",{"id":125,"libraryId":5,"type":15,"typeLabel":16,"stem":126,"options":127,"answer":20,"analysis":33},932253,"（2015真题）某地区有一条城市交通隧道，长度1500m，按照防火规范要求，隧道内设置了各种消防设施，下列关于隧道设置机械排烟系统的说法中，正确的是（）。",[128,130,132,134],{"key":20,"text":129,"correct":22},"采用纵向排烟方式时，排烟风速纵向气流的速度不应小于2m\u002FS",{"key":24,"text":131,"correct":26},"排烟风机应能在280°C下连续正常工作不小于2. 00h",{"key":28,"text":133,"correct":26},"排烟管道的耐火极限不应低于2.0h",{"key":31,"text":135,"correct":26},"机械排烟系统与隧道的通风系统应共用",{"id":137,"libraryId":5,"type":15,"typeLabel":16,"stem":138,"options":139,"answer":20,"analysis":33},932254,"（2016真题）某长度为1400m的城市交通隧道，顶棚悬挂有若干射流风机，该隧道的排烟方 式属于（ ）方式。",[140,142,144,146],{"key":20,"text":141,"correct":22},"纵向排烟",{"key":24,"text":143,"correct":26},"重点排烟",{"key":28,"text":145,"correct":26},"横向排烟",{"key":31,"text":147,"correct":26},"半横向排烟",{"id":149,"libraryId":5,"type":15,"typeLabel":16,"stem":150,"options":151,"answer":28,"analysis":33},932255,"（2018真题）某城市交通隧道，封闭段长度为1500m，可通行危险化学品车，该隧道的下列防火设计方案中，正确的是（ ）。",[152,154,156,158],{"key":20,"text":153,"correct":26},"隧道内的地下设备用房按二级耐火等级确定构件的燃烧性能和耐火极限",{"key":24,"text":155,"correct":26},"隧道的消防用房按二级负荷要求供电",{"key":28,"text":157,"correct":22},"采用耐火极限不低于2.00h的防火隔墙将隧道内设置的10Kv高压电缆与其它区域分隔",{"key":31,"text":159,"correct":26},"采用防火墙和甲级防火门将隧道内设置的可燃气体管道与其他区域分隔",{"id":161,"libraryId":5,"type":15,"typeLabel":16,"stem":162,"options":163,"answer":31,"analysis":33},932257,"（2019年真题）某单向通行的城市交通隧道，长度为3100m。根据现行国家标准《消防给水及消火栓系统技术规范》（GB 50974）， 其室内消火栓系统的下列设计方案中，错误的是（）。",[164,166,168,170],{"key":20,"text":165,"correct":26},"设置独立的临时高压消防给水系统",{"key":24,"text":167,"correct":26},"在用水量达到最大时，消火栓管道的最低供水压力为0.35MPa",{"key":28,"text":169,"correct":26},"消火栓间距为30m",{"key":31,"text":171,"correct":22},"消火栓栓口出水压力大于0.8MPa时，设置减压设施",{"id":173,"libraryId":5,"type":15,"typeLabel":16,"stem":174,"options":175,"answer":31,"analysis":33},932258,"（2019年真题）某单孔单向城市交通隧道，封闭段长度为1600m，仅限通行非危险化学品机动车。该隧道的下列设计方案中，正确的是（）。",[176,178,180,182],{"key":20,"text":177,"correct":26},"消防用电按二级负荷供电",{"key":24,"text":179,"correct":26},"在隧道两侧均设置ABC类灭火器，每个设置点2具",{"key":28,"text":181,"correct":26},"机械排烟系统采用纵向排烟方式，纵向气流速度小于临界风速",{"key":31,"text":183,"correct":22},"通风机房与车行隧道之间采用耐火极限2.00的防火隔墙和乙级防火门分隔",{"id":185,"libraryId":5,"type":15,"typeLabel":16,"stem":186,"options":187,"answer":31,"analysis":33},932259,"（2015真题）某加油站设置了 1个容积为30m3的93#汽油罐，1个容积为30m3的95#汽油罐。1个 容积为20m3的97#汽油罐，1个容积为50m3的柴油罐。按照《汽油加油加气站设计与施 工规范》GB 50156-2012 (2014年版）的规定，该加油站的等级应是（）。",[188,190,192,194],{"key":20,"text":189,"correct":26},"一级",{"key":24,"text":191,"correct":26},"三级",{"key":28,"text":193,"correct":26},"四级",{"key":31,"text":195,"correct":22},"二级",{"id":197,"libraryId":5,"type":48,"typeLabel":49,"stem":198,"options":199,"answer":210,"analysis":33},932260,"（2016真题）下列汽车加油加气站中，不应在城市中心建设的有（ ）",[200,202,204,206,208],{"key":20,"text":201,"correct":22},"一级加油站",{"key":24,"text":203,"correct":26},"LVG加油站",{"key":28,"text":205,"correct":26},"CNG常规加油站",{"key":31,"text":207,"correct":22},"一级加气站",{"key":61,"text":209,"correct":22},"一级加油加气合建站","ADE",{"id":212,"libraryId":5,"type":48,"typeLabel":49,"stem":213,"options":214,"answer":225,"analysis":33},932261,"（2015真题）下列城市汽车加油加气站中，应设消防给水系统的有（）。",[215,217,219,221,223],{"key":20,"text":216,"correct":26},"—级加油站",{"key":24,"text":218,"correct":26},"压缩天然气储罐埋地设置的加气站",{"key":28,"text":220,"correct":22},"二级液化石油气加气站",{"key":31,"text":222,"correct":22},"加油和液化石油气加气合建站",{"key":61,"text":224,"correct":26},"压缩天然气储罐埋地设置的加油加气合建站","CD",{"id":227,"libraryId":5,"type":15,"typeLabel":16,"stem":228,"options":229,"answer":31,"analysis":33},932262,"（2016真题）某汽车加油站2个单罐容积为30m3的汽油罐，1个单罐容积为50m3柴油罐。该加油站的等级是（ ）",[230,231,232,233],{"key":20,"text":189,"correct":26},{"key":24,"text":195,"correct":26},{"key":28,"text":193,"correct":26},{"key":31,"text":191,"correct":22},{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":28,"analysis":33},932263,"（2016真题）下列关于汽车加油加气站的消防设施设置和灭火器材配置的说法中，错误的是（ ）",[238,240,242,244],{"key":20,"text":239,"correct":26},"加气机应配置手提干粉灭火器",{"key":24,"text":241,"correct":26},"合建站中地上LPG设施应设置消防给水系统",{"key":28,"text":243,"correct":22},"二级加油站应配置灭火毯3块、沙子2m3",{"key":31,"text":245,"correct":26},"合建站中地上LNG储罐总容积不大于60m3可不设置消防给水",{"id":247,"libraryId":5,"type":15,"typeLabel":16,"stem":248,"options":249,"answer":31,"analysis":33},932264,"（2015真题）某新建的汽车加油、加气合建站，设置消防设施时，下列说法中，错误的是( )。",[250,252,254,256],{"key":20,"text":251,"correct":26},"在LNG储存和加气站应设置可燃气体检测报警系统",{"key":24,"text":253,"correct":26},"设置2台消防水泵时，可不设备用消防水泵",{"key":28,"text":255,"correct":26},"在加油站的罩棚下应设置事故照明",{"key":31,"text":257,"correct":22},"可燃气体检测器的一级报警值应设定为天然气爆炸下限的30%",{"id":259,"libraryId":5,"type":15,"typeLabel":16,"stem":260,"options":261,"answer":20,"analysis":33},932265,"（2017真题）下列加油加气站组合中，允许联合建站的是（ ）",[262,264,266,268],{"key":20,"text":263,"correct":22},"LPG加气站与加油站",{"key":24,"text":265,"correct":26},"CNG加气母站与加油站",{"key":28,"text":267,"correct":26},"CNG加气母站与LNG加气站",{"key":31,"text":269,"correct":26},"LPG加气站与CNG加气站",{"id":271,"libraryId":5,"type":15,"typeLabel":16,"stem":272,"options":273,"answer":28,"analysis":33},932266,"（2018真题）根据现行国家标准《汽车加油加气站设计与施工规范》(GB50156),LPG加气站内加气机与学生人数为560人的中学教学楼的最小安全间距应为( )。",[274,276,278,280],{"key":20,"text":275,"correct":26},"18m",{"key":24,"text":277,"correct":26},"25",{"key":28,"text":279,"correct":22},"100m",{"key":31,"text":281,"correct":26},"50",{"id":283,"libraryId":5,"type":15,"typeLabel":16,"stem":284,"options":285,"answer":24,"analysis":33},932267,"（2019年真题）某大型石油化工企业，设有甲类厂房及工艺装置生产区，液化罐经组区、可燃液体耀组区，全厂性高架火矩等。该企业选址及总平面布置的下列设计方案中，正确的是（）",[286,288,290,292],{"key":20,"text":287,"correct":26},"将该石油化工企业布置在四面环山，人稀少的压地带",{"key":24,"text":289,"correct":22},"在可燃液体罐组防火提内种植生长高度不超过15cm，含水分多的四季常青的草皮",{"key":28,"text":291,"correct":26},"当地一条公路穿越该企业生产区，与甲类厂房及工艺装置、液化烃储罐、可燃液体储罐均保持50m的防火间距，与高架火矩保持80m的防火间距",{"key":31,"text":293,"correct":26},"将液化烃罐组临布置在高于工艺装置的山坡平台上，井严格核相关要求设置防火堤，防止可燃液体漏流散",{"id":295,"libraryId":5,"type":48,"typeLabel":49,"stem":296,"options":297,"answer":308,"analysis":33},932268,"（2019年真题）为了 节约用地，减少管线投资并方便操作管理，满足一定安全条件的甲、乙、丙类液体储罐可成组布置。关于液化烃地上储罐成组布置的说法，正确的有（）",[298,300,302,304,306],{"key":20,"text":299,"correct":26},"组内全冷式结罐不应多于10个",{"key":24,"text":301,"correct":22},"组内的储罐不应超过2排",{"key":28,"text":303,"correct":22},"全冷冻式储罐应单独成组布置",{"key":31,"text":305,"correct":26},"组内全压力式储罐不应多于10个",{"key":61,"text":307,"correct":22},"储罐不能适应罐组内任一介质泄漏所产生的最低温度时，不应布置在同一罐组内","BCE",{"id":310,"libraryId":5,"type":15,"typeLabel":16,"stem":311,"options":312,"answer":24,"analysis":33},932269,"（2020年真题）某市计划修建1座一级加油与压缩天然气加气合建站，加油种类有0#柴油和92#、95#、98#汽油，压缩天然气采用储气井储气。下列防火设计方案中，错误的是（ ）。",[313,315,317,319],{"key":20,"text":314,"correct":26},"加油加气站选址在城市建成区之外",{"key":24,"text":316,"correct":22},"储气井容积为18m3，同时站内停放一辆容积为8m3的车载储气瓶组拖车",{"key":28,"text":318,"correct":26},"加油加气站设有卸油和加油油气回收装置",{"key":31,"text":320,"correct":26},"站内柴油储罐总容积为100m3，汽油储罐总容积为70m3",{"id":322,"libraryId":5,"type":15,"typeLabel":16,"stem":323,"options":324,"answer":24,"analysis":33},932270,"（2016真题）某燃煤火力发电厂，单机容量为200MW，总容量为1000MW。下列关于该电厂消防设施的做法中，错误的是（ ）。",[325,327,329,331],{"key":20,"text":326,"correct":26},"消防控制室与主控制室合并设置",{"key":24,"text":328,"correct":22},"贮煤场的室外消防用水量采用15L\u002Fs",{"key":28,"text":330,"correct":26},"设置控制中心火灾自动报警系统",{"key":31,"text":332,"correct":26},"主厂房周围采用环状消防给水管网",{"id":334,"libraryId":5,"type":15,"typeLabel":16,"stem":335,"options":336,"answer":31,"analysis":33},932271,"（2018真题）根据现行国家标准《火力发电厂与变电站设计防火规范》（GB50229），变电站内的总事故贮油池室外油浸变压器的最小安全间距应为（）。",[337,339,341,342],{"key":20,"text":338,"correct":26},"10m",{"key":24,"text":340,"correct":26},"15m",{"key":28,"text":275,"correct":26},{"key":31,"text":343,"correct":22},"5m",{"id":345,"libraryId":5,"type":15,"typeLabel":16,"stem":346,"options":347,"answer":24,"analysis":33},932272,"（2018真题）根据现行国家标准《火力发电厂与变电站设计防火规范》(GB50229)下列燃煤电厂内的建筑物或场所中,可以不设置室内消火栓的是（ ）",[348,350,352,354],{"key":20,"text":349,"correct":26},"网络控制楼",{"key":24,"text":351,"correct":22},"脱硫工艺楼",{"key":28,"text":353,"correct":26},"解冻室",{"key":31,"text":355,"correct":26},"集中控制楼",{"id":357,"libraryId":5,"type":15,"typeLabel":16,"stem":358,"options":359,"answer":24,"analysis":33},932273,"（2018真题）某35kv 地下变电站，设有自动灭火系统，根据现行国家标准《火力发电厂与变电站设计防火规范》（GB50229），该变电站最大防火分区建筑面积为（）。",[360,362,364,366],{"key":20,"text":361,"correct":26},"600m2",{"key":24,"text":363,"correct":22},"2000m2",{"key":28,"text":365,"correct":26},"1000m2",{"key":31,"text":367,"correct":26},"1200m2",{"id":369,"libraryId":5,"type":48,"typeLabel":49,"stem":370,"options":371,"answer":210,"analysis":33},932274,"（2017真题）某地下变电站，主变电气容量为150MV· A，该变电站的下列防火设计方案中，不符合规范要求的有（ ）",[372,374,376,378,380],{"key":20,"text":373,"correct":22},"继电器室设置感温火灾探测器",{"key":24,"text":375,"correct":26},"主控通信室设计火灾自动报警系统及疏散应急照明",{"key":28,"text":377,"correct":26},"变压器设置水喷雾灭火系统",{"key":31,"text":379,"correct":22},"电缆层设置感烟火灾探测器",{"key":61,"text":381,"correct":22},"配电装置室采用火焰探测器",{"id":383,"libraryId":5,"type":48,"typeLabel":49,"stem":384,"options":385,"answer":396,"analysis":33},932275,"（2019年真题）火力发电厂的液氨储罐区应（）",[386,388,390,392,394],{"key":20,"text":387,"correct":26},"设置不低于2.0m的不燃烧实体围墙",{"key":24,"text":389,"correct":22},"位于厂区全年最小频率风向的上风侧",{"key":28,"text":391,"correct":26},"与厂外道路保持15m以上的防火间距",{"key":31,"text":393,"correct":22},"布置在通风良好的厂区边缘地带",{"key":61,"text":395,"correct":22},"避开人员集中活动场所和主要人流出入口","BDE",{"id":398,"libraryId":5,"type":15,"typeLabel":16,"stem":399,"options":400,"answer":28,"analysis":33},932276,"（2019年真题）某燃煤电厂的汽机房按相关规定设置了火灾自动报警系统和自动灭火系统，汽机房最远工作地点到直通室外的安全出口或疏散楼梯的距离不应大于（）。",[401,403,405,407],{"key":20,"text":402,"correct":26},"30m",{"key":24,"text":404,"correct":26},"40m",{"key":28,"text":406,"correct":22},"75m",{"key":31,"text":408,"correct":26},"50m",{"id":410,"libraryId":5,"type":15,"typeLabel":16,"stem":411,"options":412,"answer":31,"analysis":33},932277,"（2019年真题）某地下变电站设有4台变压器，其中，额定容量为5MV.A的35kV铝线电力变压器2台，每台存油量2.5t；额定容量为10MV.A的110kV双卷铝线电力受压器2台，每台存油量5.0t。该变电站的事故贮油池最小容量应是（?）。",[413,415,417,419],{"key":20,"text":414,"correct":26},"2.5t",{"key":24,"text":416,"correct":26},"7. 5t",{"key":28,"text":418,"correct":26},"15.0t",{"key":31,"text":420,"correct":22},"5.0t",{"id":422,"libraryId":5,"type":15,"typeLabel":16,"stem":423,"options":424,"answer":20,"analysis":33},932278,"（2019年真题）某燃煤火力发电厂，单机容量200MW，该发电厂火灾自动报警系统的下列设计方案中，正确的是（）",[425,427,429,431],{"key":20,"text":426,"correct":22},"运煤系统内的火灾探测器防护等级为IP65",{"key":24,"text":428,"correct":26},"厂区设置集中报警系统。",{"key":28,"text":430,"correct":26},"消防控制室与集中控制室分别独立设置",{"key":31,"text":432,"correct":26},"灭火过程中，消防水泵根据管网压力变化自动启停",{"id":434,"libraryId":5,"type":15,"typeLabel":16,"stem":435,"options":436,"answer":20,"analysis":33},932279,"（2020年真题）某厂区内拟布置一座10kV室内变电站，为该厂区内的1座甲类厂房和1座乙类厂房供电，变电站和两座厂房均为单层，耐火等级均为二级。该厂区变电站的布置方案正确的是（??）。",[437,439,441,443],{"key":20,"text":438,"correct":22},"变电站独立建造时，油浸变压器室设置在地下",{"key":24,"text":440,"correct":26},"受厂区平面布局限制，变电站与甲类厂房一面贴邻",{"key":28,"text":442,"correct":26},"受厂区平面布局限制，变电站与乙类厂房两面贴邻",{"key":31,"text":444,"correct":26},"变电站独立建造时，与甲类房的防火间距为10m",{"id":446,"libraryId":5,"type":15,"typeLabel":16,"stem":447,"options":448,"answer":31,"analysis":33},932280,"（2020年真题）关于电气线路选型与敷设的说法，正确的是（ ）。",[449,451,453,455],{"key":20,"text":450,"correct":26},"消防电源回路选用铝芯电线电缆",{"key":24,"text":452,"correct":26},"有爆炸危险场所的电力线路采用架空方式敷设",{"key":28,"text":454,"correct":26},"室内电气线路直接敷设在木质装修材料上",{"key":31,"text":456,"correct":22},"铜芯电线电缆成束敷设时,采用阻燃型电线电缆",{"id":458,"libraryId":5,"type":15,"typeLabel":16,"stem":459,"options":460,"answer":31,"analysis":33},932281,"（2020年真题）白炽灯的额定功率只要大于（ ）W，其引入线就能采用瓷管、矿棉等不然材料作隔热保护。",[461,462,464,466],{"key":20,"text":277,"correct":26},{"key":24,"text":463,"correct":26},"60",{"key":28,"text":465,"correct":26},"200",{"key":31,"text":467,"correct":22},"100",{"id":469,"libraryId":5,"type":15,"typeLabel":16,"stem":470,"options":471,"answer":28,"analysis":33},932282,"（2015真题）新建一座地下汽车库，建筑面积为15000m3,停车在300辆，汽车车库按规定设立了消防设施。该汽车库室内任一点至最近人员安全出口的疏散距离不应大于（）。",[472,474,475,476],{"key":20,"text":473,"correct":26},"45",{"key":24,"text":281,"correct":26},{"key":28,"text":463,"correct":22},{"key":31,"text":477,"correct":26},"80",{"id":479,"libraryId":5,"type":48,"typeLabel":49,"stem":480,"options":481,"answer":492,"analysis":33},932283,"（2015真题）某寒冷地区环境温度低于4摄氏度,有一个地上3层、建筑面积40000m2的汽车库，未设置采暖设施。该汽车库设置自动喷水灭火系统时，可采用（）等系统。",[482,484,486,488,490],{"key":20,"text":483,"correct":22},"干式",{"key":24,"text":485,"correct":22},"预作用",{"key":28,"text":487,"correct":26},"自动喷水--泡沬联用",{"key":31,"text":489,"correct":26},"湿式",{"key":61,"text":491,"correct":26},"雨淋","AB",{"id":494,"libraryId":5,"type":48,"typeLabel":49,"stem":495,"options":496,"answer":507,"analysis":33},932284,"（2015真题）新建一座大型的商业建筑，地下一层为汽车库，可停放300辆汽车，下列设施和房间中，不应设置在该地下汽车库内的有（）。",[497,499,501,503,505],{"key":20,"text":498,"correct":22},"汽油罐",{"key":24,"text":500,"correct":22},"加油机",{"key":28,"text":502,"correct":22},"修理车位",{"key":31,"text":504,"correct":26},"丙类库房",{"key":61,"text":506,"correct":22},"充电间","ABCE",{"id":509,"libraryId":5,"type":48,"typeLabel":49,"stem":510,"options":511,"answer":210,"analysis":33},932285,"（2016真题）下列汽车库，修车库，停车场中，可不设置自动喷水灭火系统的有（ ）",[512,514,516,518,520],{"key":20,"text":513,"correct":22},"IV类地上汽车库",{"key":24,"text":515,"correct":26},"机械式汽车库",{"key":28,"text":517,"correct":26},"I类汽车库",{"key":31,"text":519,"correct":22},"屋面停车场",{"key":61,"text":521,"correct":22},"停车数量为10辆的地下停车库",{"id":523,"libraryId":5,"type":15,"typeLabel":16,"stem":524,"options":525,"answer":31,"analysis":33},932286,"（2016真题）某汽车库的建筑面积为5100m2，停车数量为150辆，该汽车库的防火分类应为（ ）。",[526,528,530,532],{"key":20,"text":527,"correct":26},"Ⅰ",{"key":24,"text":529,"correct":26},"Ⅲ",{"key":28,"text":531,"correct":26},"Ⅳ",{"key":31,"text":533,"correct":22},"Ⅱ",{"id":535,"libraryId":5,"type":15,"typeLabel":16,"stem":536,"options":537,"answer":24,"analysis":33},932287,"（2016真题）某设置110个停车位的室内无车道且无人员停留的机械式地下汽车库，下列自动灭火系统中不适用于改车库的是（ ）",[538,540,542,544],{"key":20,"text":539,"correct":26},"湿式自动喷水灭火系统",{"key":24,"text":541,"correct":22},"二氧化碳灭火系统",{"key":28,"text":543,"correct":26},"泡沫—水喷雾灭火系统",{"key":31,"text":545,"correct":26},"高倍数泡沫灭火系统",{"id":547,"libraryId":5,"type":15,"typeLabel":16,"stem":548,"options":549,"answer":31,"analysis":33},932289,"（2017真题）下列场所中，不需要设置火灾自动报警系统的是（ ）。",[550,552,554,556],{"key":20,"text":551,"correct":26},"高层建筑首层停车数为200辆的汽车库",{"key":24,"text":553,"correct":26},"采用汽车专用升降机做汽车疏散出口的汽车库",{"key":28,"text":555,"correct":26},"停车数为350辆的单层汽车库",{"key":31,"text":557,"correct":22},"采用机械设备进行垂直或水平移动形式停放汽车的敞开汽车库",{"id":559,"libraryId":5,"type":15,"typeLabel":16,"stem":560,"options":561,"answer":24,"analysis":33},932290,"（2017真题）根据《汽车库、修车库、停车场设计防火规范》GB 50967，关于室外消火栓用水量的说法，正确的是（ ）。",[562,564,566,568],{"key":20,"text":563,"correct":26},"II类汽车库、修车库、停车场室外消火栓用水量不应小于15L\u002Fs",{"key":24,"text":565,"correct":22},"I类汽车库、修车库、停车场室外消火栓用水量不应小于20L\u002Fs",{"key":28,"text":567,"correct":26},"III类汽车库修车库、停车场室外消火栓用水量不应小于10L\u002Fs",{"key":31,"text":569,"correct":26},"IV类汽车库修车库、停车场室外消火栓用水量不应小于5L\u002Fs",{"id":571,"libraryId":5,"type":15,"typeLabel":16,"stem":572,"options":573,"answer":28,"analysis":33},932291,"（2017真题）下列关于汽车库防火设计的做法中，不符合规范要求的是( )。",[574,576,578,580],{"key":20,"text":575,"correct":26},"社区幼儿园与地下车库之间采用耐火极限不低于2．00h的楼板完全分隔，安全出口和疏散楼梯分别独立设置",{"key":24,"text":577,"correct":26},"地下二层设置汽车库、设备用房、存放丙类物品的工具库和自行车库",{"key":28,"text":579,"correct":22},"地下一层汽车房附设一个修理车位，一个喷漆间",{"key":31,"text":581,"correct":26},"地下二层设置谷物运输车、大巴车和垃圾运输车间",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":31,"analysis":33},932292,"（2018真题）某公共建筑的地下一层至地下三层为汽车库，每层建筑面积为2000㎡每层设有50车位。根据现行国家标住《汽车库、修车库、停车场设计防火规范》(GB5007）该汽车库属于（ ）车库。",[586,588,590,592],{"key":20,"text":587,"correct":26},"Ⅰ类",{"key":24,"text":589,"correct":26},"Ⅲ类",{"key":28,"text":591,"correct":26},"Ⅳ类",{"key":31,"text":593,"correct":22},"Ⅱ类",{"id":595,"libraryId":5,"type":15,"typeLabel":16,"stem":596,"options":597,"answer":24,"analysis":33},932293,"（2018真题）根据现行国家标准《汽车库、修车库、停车场设计防火规范》关于汽车库排烟设计的说法，错误的是（）。",[598,600,602,604],{"key":20,"text":599,"correct":26},"建筑面积为 1000 ㎡的地下一层汽车库应设置排烟系统",{"key":24,"text":601,"correct":22},"自然排烟口的总面积不应小于室内地面面积的 1％",{"key":28,"text":603,"correct":26},"防烟分区的建筑面积不宜大于 2000m",{"key":31,"text":605,"correct":26},"用从顶棚下突出 0.5m 的梁来划分防烟分区",{"id":607,"libraryId":5,"type":15,"typeLabel":16,"stem":608,"options":609,"answer":20,"analysis":33},932294,"（2018真题）根据现行国家标准在《汽车库、修车库、停车场设计防火规范》(GB50067)汽车库的下列防火设计方案中正确的是（ ）。",[610,612,614,616],{"key":20,"text":611,"correct":22},"汽车库外墙上、下层开口之间设置宽度为1.0m的防火挑檐",{"key":24,"text":613,"correct":26},"汽年库与商场之间采用耐火极限为3.00h的防火隔墙分隔",{"key":28,"text":615,"correct":26},"汽车库与商场之间采用耐火极限为1.50h的楼板分隔",{"key":31,"text":617,"correct":26},"汽年库外墙上、下层开口之间设置高度为1.0m的实体墙",{"id":619,"libraryId":5,"type":15,"typeLabel":16,"stem":620,"options":621,"answer":24,"analysis":33},932295,"（2018真题）为修车库服务的下列附属建筑中，可与修车库贴邻，但应采用防火隔开，并应设置直通室外的安全出口是（ ）。",[622,624,626,628],{"key":20,"text":623,"correct":26},"贮存6个标准钢瓶的乙块气瓶库",{"key":24,"text":625,"correct":22},"贮存量为1.0t的甲类物品库房",{"key":28,"text":627,"correct":26},"3个车位的封闭喷漆间",{"key":31,"text":629,"correct":26},"总安装流量为6m3\u002Fh的乙炔发生器间",{"id":631,"libraryId":5,"type":15,"typeLabel":16,"stem":632,"options":633,"answer":31,"analysis":33},932296,"（2018真题）根据现行国家标准《汽车库、修车库、停车场设计防火规范》(CB50067),附设在幼儿园建筑地下部分的汽车库的下列设计方案中,正确的是( )。",[634,636,638,640],{"key":20,"text":635,"correct":26},"汽车库与幼儿园的疏散楼梯在首层采用耐火极限为3.O0h的防火隔墙和甲级防火门分隔",{"key":24,"text":637,"correct":26},"汽车库与幼儿园的疏散楼梯在首层采用耐火极限为2.00h的防火隔墙和乙级防火门分隔",{"key":28,"text":639,"correct":26},"汽车库内设1个面积为100m2的充电间",{"key":31,"text":641,"correct":22},"汽车库与幼儿园之间采用耐火极限为2.00h的楼板完全分隔",[643,646,649,652,655,658],{"id":15,"name":644,"category":7,"favorite":645},"领导干部任职前廉政法规知识测试题",92,{"id":647,"name":648,"category":7,"favorite":15},595,"建筑结构与设备",{"id":650,"name":651,"category":7,"favorite":15},715,"招标采购专业知识与法律法规",{"id":653,"name":654,"category":7,"favorite":15},848,"市政方向-通用基础",{"id":656,"name":657,"category":7,"favorite":8},534,"BIM工程师",{"id":659,"name":657,"category":7,"favorite":8},535]