[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"lib-604-1":3},{"library":4,"page":9,"limit":10,"total":11,"questions":12,"related":628},{"id":5,"name":6,"category":7,"favorite":8},604,"消防安全技术实务(一级)","建筑工程",0,1,50,2960,[13,38,51,66,78,90,102,114,126,138,152,164,174,186,198,210,222,234,249,259,271,279,291,305,317,329,344,356,368,380,392,400,412,424,436,448,460,472,482,494,506,521,533,548,560,570,582,597,606,617],{"id":14,"libraryId":5,"type":15,"typeLabel":16,"stem":17,"options":18,"answer":36,"analysis":37},931676,2,"多选题","（2015真题）某化工企业拟采用安全检查表法对甲醇合成车间进行火灾风险评估。编制安全检查表的主要步骤应包括（ ）。",[19,23,26,30,33],{"key":20,"text":21,"correct":22},"A","确定检查对象",true,{"key":24,"text":25,"correct":22},"B","找出危险点",{"key":27,"text":28,"correct":29},"C","预案演练",false,{"key":31,"text":32,"correct":22},"D","确定检查内容",{"key":34,"text":35,"correct":22},"E","编制检查表","ABDE","",{"id":39,"libraryId":5,"type":9,"typeLabel":40,"stem":41,"options":42,"answer":31,"analysis":37},931677,"单选题","（2018真题）关于火灾风险评估方法的说法,正确的是（ ）。",[43,45,47,49],{"key":20,"text":44,"correct":29},"在评估对象运营之前，采用表格方式对潜在火灾危险性进行评估的方法采用安全检查表法",{"key":24,"text":46,"correct":29},"运用事故树方法进行火灾风险评估时，每一事件可能的后续事件只能取完全对立的两种状态之一",{"key":27,"text":48,"correct":29},"运用运筹学原理，对火灾事故原因和结果进行逻辑分析的方法属于事件树分析方法",{"key":31,"text":50,"correct":22},"运用安全检查表法进行火灾风险评估时，可通过事故树进行定性分析出评估对象的薄弱环节，将其作为安全检查的重点",{"id":52,"libraryId":5,"type":15,"typeLabel":16,"stem":53,"options":54,"answer":65,"analysis":37},931678,"（2016真题）在进行火灾风险评估中采用事件树分析法进行分析时，确切初始事件的方法有（ ）",[55,57,59,61,63],{"key":20,"text":56,"correct":22},"根据系统设计确定",{"key":24,"text":58,"correct":22},"很掘系统危险性评价确定",{"key":27,"text":60,"correct":22},"根据系统运行经验或事故经验确定",{"key":31,"text":62,"correct":22},"根据系统事故树分析，从其中间事件或初始时间中选择",{"key":34,"text":64,"correct":29},"根据结果时间确定","ABCD",{"id":67,"libraryId":5,"type":9,"typeLabel":40,"stem":68,"options":69,"answer":24,"analysis":37},931679,"（2015真题）进行火灾风险识别中，需判定火灾危险源。下列火灾危险源因素中，属于人为因素的是(）。",[70,72,74,76],{"key":20,"text":71,"correct":29},"人员应急反应能力",{"key":24,"text":73,"correct":22},"吸烟起火",{"key":27,"text":75,"correct":29},"消防安全责任",{"key":31,"text":77,"correct":29},"可燃油浸变压器油温过高引起起火",{"id":79,"libraryId":5,"type":9,"typeLabel":40,"stem":80,"options":81,"answer":31,"analysis":37},931680,"（2016真题）对某石油库迸行火灾风险评估，辨识火灾危险源时，下列因素中，应确定为第一类危险源的是（ ）。",[82,84,86,88],{"key":20,"text":83,"correct":29},"雷电",{"key":24,"text":85,"correct":29},"油罐呼吸阀故障",{"key":27,"text":87,"correct":29},"操作人员在卸油时打手机",{"key":31,"text":89,"correct":22},"2000m3的柴油罐",{"id":91,"libraryId":5,"type":9,"typeLabel":40,"stem":92,"options":93,"answer":20,"analysis":37},931681,"（2017真题）影响公共建筑疏散设计指标的主要因素是()。",[94,96,98,100],{"key":20,"text":95,"correct":22},"人员密度",{"key":24,"text":97,"correct":29},"人员对环境的熟知度",{"key":27,"text":99,"correct":29},"人员心理承受能力",{"key":31,"text":101,"correct":29},"人员身体状况",{"id":103,"libraryId":5,"type":9,"typeLabel":40,"stem":104,"options":105,"answer":20,"analysis":37},931682,"（2020年真题）根据火灾风险源分析原理，下列设备、设施中，属于被动防火系统的是（ ）。",[106,108,110,112],{"key":20,"text":107,"correct":22},"消防电梯",{"key":24,"text":109,"correct":29},"灭火器",{"key":27,"text":111,"correct":29},"火灾探测器",{"key":31,"text":113,"correct":29},"疏散走道",{"id":115,"libraryId":5,"type":9,"typeLabel":40,"stem":116,"options":117,"answer":24,"analysis":37},931683,"（2016真题）在开展建筑消防性能化设计与评估时，预测自动喷水灭火系统洒水喷头的启动时间，主要应考虑火灾的（ ）。",[118,120,122,124],{"key":20,"text":119,"correct":29},"阴燃",{"key":24,"text":121,"correct":22},"增长",{"key":27,"text":123,"correct":29},"全面发展",{"key":31,"text":125,"correct":29},"衰退",{"id":127,"libraryId":5,"type":9,"typeLabel":40,"stem":128,"options":129,"answer":20,"analysis":37},931684,"（2015真题）对建筑进行性能化防火设计时，火灾数值模拟软件FDS采用的火灾模型是（）",[130,132,134,136],{"key":20,"text":131,"correct":22},"场模型",{"key":24,"text":133,"correct":29},"局部模型",{"key":27,"text":135,"correct":29},"区域模型",{"key":31,"text":137,"correct":29},"混合模型",{"id":139,"libraryId":5,"type":15,"typeLabel":16,"stem":140,"options":141,"answer":151,"analysis":37},931685,"（2015真题）对建筑进行性能化防火设计评估中，在计算人员安全疏散时间时，应确定人员密度、疏散宽度、行走速度等相关参数。行走速度的确定需要考虑影响行走速度的因素。影响行走速度的因素主要包括( )。",[142,144,146,148,150],{"key":20,"text":143,"correct":29},"灭火器设置",{"key":24,"text":145,"correct":22},"人员自身条件",{"key":27,"text":147,"correct":29},"报警时间",{"key":31,"text":149,"correct":22},"建筑情况",{"key":34,"text":95,"correct":22},"BDE",{"id":153,"libraryId":5,"type":9,"typeLabel":40,"stem":154,"options":155,"answer":24,"analysis":37},931686,"（2016真题）下列情形中，有利于火灾时缩短人员疏散时间的是（ ）。",[156,158,160,162],{"key":20,"text":157,"correct":29},"正常照明转换为应急照明",{"key":24,"text":159,"correct":22},"背景音乐转为火灾应急广播",{"key":27,"text":161,"correct":29},"疏散通道上的防火卷帘落下",{"key":31,"text":163,"correct":29},"自动喷水灭火系统喷头启动洒水",{"id":165,"libraryId":5,"type":9,"typeLabel":40,"stem":166,"options":167,"answer":31,"analysis":37},931688,"（2017真题）将计算空间划分为众多相互关联的体积元，通过求解质量，能量和动量方程，获得空间热参数在设定时间步长内变化情况的预测，以描述火灾发展过程的模型属于（ ）",[168,170,171,173],{"key":20,"text":169,"correct":29},"经验模型",{"key":24,"text":135,"correct":29},{"key":27,"text":172,"correct":29},"不确定模型",{"key":31,"text":131,"correct":22},{"id":175,"libraryId":5,"type":9,"typeLabel":40,"stem":176,"options":177,"answer":27,"analysis":37},931689,"（2017真题）按下图估算，200人按疏散指示有序通过一个净宽度为2m且直接对外的疏散出口疏散至室外，其最快疏散时间约为（ ）s。",[178,180,182,184],{"key":20,"text":179,"correct":29},"40",{"key":24,"text":181,"correct":29},"60",{"key":27,"text":183,"correct":22},"80",{"key":31,"text":185,"correct":29},"100",{"id":187,"libraryId":5,"type":9,"typeLabel":40,"stem":188,"options":189,"answer":27,"analysis":37},931690,"（2017真题）采用燃烧性能为A级，耐火极限≥1h的秸秆纤维板材组装的预测环保塑板房，可广泛用于施工工地和灾区过道设置，在静风状态下，对板房进行实体火灾试验，测得距着火板房外墙各测点的最大热辐射如下表所示，据此可判定，该板房安全经济的防火间距时（ ）",[190,192,194,196],{"key":20,"text":191,"correct":29},"1.0",{"key":24,"text":193,"correct":29},"2.0",{"key":27,"text":195,"correct":22},"3.0",{"key":31,"text":197,"correct":29},"4.0",{"id":199,"libraryId":5,"type":9,"typeLabel":40,"stem":200,"options":201,"answer":27,"analysis":37},931691,"（2019年真题）某仓库储存一定量的可燃材料，火源热释放速率达 1MW时。火灾发展所需时间为292S， 库内未设置自动喷水灭火系统，若不考虑火灾初明的点燃过程，则仓库储存的材料可能是（）?",[202,204,206,208],{"key":20,"text":203,"correct":29},"塑料料泡",{"key":24,"text":205,"correct":29},"堆放的木架",{"key":27,"text":207,"correct":22},"聚酯床垫",{"key":31,"text":209,"correct":29},"易燃的装饰家具",{"id":211,"libraryId":5,"type":9,"typeLabel":40,"stem":212,"options":213,"answer":31,"analysis":37},931692,"（2017真题）下列建筑场所中，可不设置室外消火栓的是()。",[214,216,218,220],{"key":20,"text":215,"correct":29},"用于消防救援和消防车停靠的屋面上",{"key":24,"text":217,"correct":29},"高层民用建筑",{"key":27,"text":219,"correct":29},"3层居住区，居住人数≤500人",{"key":31,"text":221,"correct":22},"耐火等级不低于二级，且建筑物体积≤3000m3的戊类厂房",{"id":223,"libraryId":5,"type":9,"typeLabel":40,"stem":224,"options":225,"answer":24,"analysis":37},931693,"（2015真题）某可燃物堆场，室外消火栓的设计流量为55L\u002Fs，室外消火栓选用DN150，其出流量为15L\u002Fs。根据室外消火栓设计流量，该堆场的室外消火栓数量不应少于（）个。",[226,228,230,232],{"key":20,"text":227,"correct":29},"6",{"key":24,"text":229,"correct":22},"4",{"key":27,"text":231,"correct":29},"5",{"key":31,"text":233,"correct":29},"3",{"id":235,"libraryId":5,"type":15,"typeLabel":16,"stem":236,"options":237,"answer":248,"analysis":37},931694,"（2017真题）关于消防水泵控制的说法，正确的有（）。",[238,240,242,244,246],{"key":20,"text":239,"correct":22},"消防水泵出水干管上设置的压力开关应能控制消防水泵的启动",{"key":24,"text":241,"correct":29},"消防水泵出水干管上设置的压力开关应能控制消防水泵的停止",{"key":27,"text":243,"correct":22},"消防控制室应能控制消防水泵启动",{"key":31,"text":245,"correct":22},"消防水泵控制柜应能控制消防水泵启动，停止",{"key":34,"text":247,"correct":29},"手动火灾报警按钮信号应能直接启动消防水泵","ACD",{"id":250,"libraryId":5,"type":9,"typeLabel":40,"stem":251,"options":252,"answer":24,"analysis":37},931695,"（2015真题）某商业建筑，东西长为100m、南北宽为60m、建筑高度26m，室外消火栓设计流量为40L\u002Fs，南侧布置消防扑救面。沿该建筑南侧消防扑救面设置的室外消火栓数量，不应少于（ ）个。",[253,255,256,257],{"key":20,"text":254,"correct":29},"1",{"key":24,"text":233,"correct":22},{"key":27,"text":229,"correct":29},{"key":31,"text":258,"correct":29},"2",{"id":260,"libraryId":5,"type":9,"typeLabel":40,"stem":261,"options":262,"answer":31,"analysis":37},931696,"（2015真题）某建筑采用临时高压消防给水系统，经计算消防水泵设计扬程为0.90MPa。选择消防水泵时，消防水泵零流量时的压力应在（）MPa之间。",[263,265,267,269],{"key":20,"text":264,"correct":29},"0.90~1.08",{"key":24,"text":266,"correct":29},"1.26~1.35",{"key":27,"text":268,"correct":29},"1.26~1.44",{"key":31,"text":270,"correct":22},"1.08~1.26",{"id":272,"libraryId":5,"type":9,"typeLabel":40,"stem":273,"options":274,"answer":24,"analysis":37},931697,"（2015真题）某高层办公楼，建筑高度为32m，内走廊为“一”字形，设置两座防烟楼梯间，其前室入口的中心线间距为15m，走廊两端的袋形走道长度为3m,走廊两侧房间进深均为6m。该办公楼每层设置的室内消火栓竖管数量不应少于（）。",[275,276,277,278],{"key":20,"text":254,"correct":29},{"key":24,"text":258,"correct":22},{"key":27,"text":233,"correct":29},{"key":31,"text":229,"correct":29},{"id":280,"libraryId":5,"type":9,"typeLabel":40,"stem":281,"options":282,"answer":20,"analysis":37},931698,"（2016真题）建筑高度为48m的16层住宅建筑，一梯3户，每户建筑面积为120㎡，每单元设置一座防烟楼梯间，一部消防电梯和一部客梯。该建筑每个单元需设置的室内消火栓总数不应少于（）个。",[283,285,287,289],{"key":20,"text":284,"correct":22},"16",{"key":24,"text":286,"correct":29},"8",{"key":27,"text":288,"correct":29},"32",{"key":31,"text":290,"correct":29},"48",{"id":292,"libraryId":5,"type":15,"typeLabel":16,"stem":293,"options":294,"answer":151,"analysis":37},931699,"（2016真题）下列关于消防水泵选用的说法中，正确的有（）。",[295,297,299,301,303],{"key":20,"text":296,"correct":29},"柴油机消防水泵应采用火花塞点火型柴油机",{"key":24,"text":298,"correct":22},"消防水泵流量一扬程性能曲线应平滑，无拐点，无驼峰",{"key":27,"text":300,"correct":29},"消防给水同一泵组的消防水泵型号应一致，且工作泵不宜超过5台",{"key":31,"text":302,"correct":22},"消防水泵泵轴的密封方式和材料应满足消防水泵在低流量时运转的要求",{"key":34,"text":304,"correct":22},"电动机驱动的消防水泵，应选择电动机干式安装的消防水泵",{"id":306,"libraryId":5,"type":9,"typeLabel":40,"stem":307,"options":308,"answer":20,"analysis":37},931700,"（2016真题）下列关于室外消火栓设置的说法中，错误的是（）。",[309,311,313,315],{"key":20,"text":310,"correct":22},"室外消火栓应集中布置在建筑消防扑救面一侧，且不小于2个",{"key":24,"text":312,"correct":29},"室外消火栓的保护半径不应大于150m",{"key":27,"text":314,"correct":29},"地下民用建筑应在入口附近设置室外消火栓，且距离出入口不宜小于5m，不宜大于40m",{"key":31,"text":316,"correct":29},"停车场的室外消火栓与最近一排汽车的距离不宜小于7m",{"id":318,"libraryId":5,"type":9,"typeLabel":40,"stem":319,"options":320,"answer":24,"analysis":37},931701,"（2016真题）下列关于建筑室内消火栓设置的说法中，错误的是（）。",[321,323,325,327],{"key":20,"text":322,"correct":29},"消防电梯前室应设置室内消火栓，并应计入消火拴使用数量",{"key":24,"text":324,"correct":22},"设置室内消火栓的建筑，超过2.2m的设备层宜设置室内消火栓",{"key":27,"text":326,"correct":29},"冷库的室内消火栓应设置在常温穿堂或楼梯间内",{"key":31,"text":328,"correct":29},"屋顶设置直升机停机坪的建筑，应在停机坪出入口处设置消火栓",{"id":330,"libraryId":5,"type":15,"typeLabel":16,"stem":331,"options":332,"answer":343,"analysis":37},931702,"（2015真题）某建筑高度为23.8m的4层商业建筑，对其进行室内消火栓的配置和设计中，正确的有（）。",[333,335,337,339,341],{"key":20,"text":334,"correct":22},"选用DN65的室内消火栓",{"key":24,"text":336,"correct":29},"消火栓栓口动压大于0.5MPa",{"key":27,"text":338,"correct":22},"消火栓栓口动压不小于0.25MPa",{"key":31,"text":340,"correct":29},"配置直径65mm长30m的消防水带",{"key":34,"text":342,"correct":22},"水枪充实水柱不小于10m","ACE",{"id":345,"libraryId":5,"type":9,"typeLabel":40,"stem":346,"options":347,"answer":24,"analysis":37},931703,"（2017真题）下列建筑或场所中，可不设置室内消火栓的是（）。",[348,350,352,354],{"key":20,"text":349,"correct":29},"占地面积500m2的丙类仓库",{"key":24,"text":351,"correct":22},"粮食仓库",{"key":27,"text":353,"correct":29},"高层公共建筑",{"key":31,"text":355,"correct":29},"建筑体积5000m3耐火等级三级的丁类厂房",{"id":357,"libraryId":5,"type":9,"typeLabel":40,"stem":358,"options":359,"answer":24,"analysis":37},931704,"（2018真题）某单层丙类厂房，室内净空高度为7m，该建筑室内消火栓系统最不利点消火栓栓口最低动压应为（ ）2018真题",[360,362,364,366],{"key":20,"text":361,"correct":29},"0.10MPa",{"key":24,"text":363,"correct":22},"0.35MPa",{"key":27,"text":365,"correct":29},"0.25MPa",{"key":31,"text":367,"correct":29},"0.50MPa",{"id":369,"libraryId":5,"type":9,"typeLabel":40,"stem":370,"options":371,"answer":27,"analysis":37},931705,"（2018真题）某工业园区地块内有5座单层丙类厂房，耐火等级为二级，其中2座厂房建筑高度为5m，占地均为1000㎡，3座高为10m，占地均为2000㎡，相邻厂房防火间距为6m，各厂房自然排烟。该工业园地块室外消火栓设计流量至少为（ ）.",[372,374,376,378],{"key":20,"text":373,"correct":29},"20L\u002Fs",{"key":24,"text":375,"correct":29},"25L\u002Fs",{"key":27,"text":377,"correct":22},"30L\u002Fs",{"key":31,"text":379,"correct":29},"40L\u002Fs",{"id":381,"libraryId":5,"type":9,"typeLabel":40,"stem":382,"options":383,"answer":24,"analysis":37},931706,"（2018真题）某2层商业建筑，呈矩形布置，建筑东西长为80m，南北宽为50m，该建筑室外消火栓设计流量为30L\u002Fs，周围无可利用的市政消火栓。该建筑周边至少应设置（ ）室外消火栓。",[384,386,388,390],{"key":20,"text":385,"correct":29},"2个",{"key":24,"text":387,"correct":22},"3个",{"key":27,"text":389,"correct":29},"4个",{"key":31,"text":391,"correct":29},"5个",{"id":393,"libraryId":5,"type":9,"typeLabel":40,"stem":394,"options":395,"answer":24,"analysis":37},931707,"（2018真题）某高层宿舍楼,标准层内走道长度为66m,走道两侧布置进深5m、建筑面积不超过20㎡的宿舍和附属用房,走道两端各设置一部疏散楼梯,室内消火栓设计流量为20L\u002Fs。该建筑每个标准层至少应设（ ）室内消火栓。",[396,397,398,399],{"key":20,"text":385,"correct":29},{"key":24,"text":389,"correct":22},{"key":27,"text":387,"correct":29},{"key":31,"text":391,"correct":29},{"id":401,"libraryId":5,"type":9,"typeLabel":40,"stem":402,"options":403,"answer":24,"analysis":37},931708,"（2018真题）某一类高层商业建筑，室内消火栓系统设计流量为30L\u002Fs。该建筑室内消火栓系统设计灭火用水量至少应为（ ）。",[404,406,408,410],{"key":20,"text":405,"correct":29},"108m3",{"key":24,"text":407,"correct":22},"324m3",{"key":27,"text":409,"correct":29},"216m3",{"key":31,"text":411,"correct":29},"432m3",{"id":413,"libraryId":5,"type":9,"typeLabel":40,"stem":414,"options":415,"answer":27,"analysis":37},931709,"（2018真题）某多层科研楼设有室内消防给水系统，消防水泵采用两台离心式消防水泵，一用一备，该组消防水泵管路的下列设计方案中，正确的是（ ）。",[416,418,420,422],{"key":20,"text":417,"correct":29},"2台消防水泵的2条DN150吸水管通过1条DN200钢管接入消防水池",{"key":24,"text":419,"correct":29},"2台消防水泵的2条DN150吸水管均采用同心异径管件与水泵相连",{"key":27,"text":421,"correct":22},"消防水泵吸水口处设置吸水井，喇叭口在消防水池最低有效水位下的淹没深度为650mm",{"key":31,"text":423,"correct":29},"消防水泵吸水口处设置旋流防止器，其在消防水池最低有效水位下的淹没深度为150mm",{"id":425,"libraryId":5,"type":9,"typeLabel":40,"stem":426,"options":427,"answer":31,"analysis":37},931710,"（2018真题）根据现行国家标准,《消防给水及消火栓系统技术规范》（GB50974）关于市政消防栓设置的说法,正确的是（ ）。",[428,430,432,434],{"key":20,"text":429,"correct":29},"市政消防栓最大保护半径应为120m",{"key":24,"text":431,"correct":29},"当市政道路宽度不超过65m时,可在道路的一侧设置市政消防栓",{"key":27,"text":433,"correct":29},"当市政消防栓距路边不宜小于0.5m不应大于5m",{"key":31,"text":435,"correct":22},"室外地下室消火栓应设置直径为100mm和65mm的栓口各一个",{"id":437,"libraryId":5,"type":9,"typeLabel":40,"stem":438,"options":439,"answer":31,"analysis":37},931711,"（2016真题）下列关于储罐区和工艺装置区室外消火栓的说法中，错误的是（ ）。",[440,442,444,446],{"key":20,"text":441,"correct":29},"可燃液体储罐区的室外消火栓，应设置在防火提外，距离罐壁15m范围内的消火栓不应计入该罐缸可使用的消火栓数量",{"key":24,"text":443,"correct":29},"采用临时高压消防给水系统的工艺装置区，室外消火栓的间距不应大于60m",{"key":27,"text":445,"correct":29},"采用高压消防给水系统且宽带大于120m的工艺装置区，宜在该工艺装置区内的路边设置室外消火栓",{"key":31,"text":447,"correct":22},"液化烃储罐区的室外消火栓，应设置在防护墙外，距离罐壁15m范围内的消火栓可计入该罐可使用的消火栓数量",{"id":449,"libraryId":5,"type":9,"typeLabel":40,"stem":450,"options":451,"answer":27,"analysis":37},931712,"（2016真题）下列关于消防给水设施的说法中，错误的是（ ）。",[452,454,456,458],{"key":20,"text":453,"correct":29},"消防水泵的串联可在流量不变的情况下增加扬程，消防水泵的并联可增加流量",{"key":24,"text":455,"correct":29},"消防水泵控制柜在平时应使消防水泵处于自动启泵状态",{"key":27,"text":457,"correct":22},"室内消火栓给水管网宜与自动喷水等其他灭火系统的管网分开设置，当合用消防水泵时，供水管路沿水流方向应在报警阀分开后设置",{"key":31,"text":459,"correct":29},"室外消防给水管道应采用阀门分成若干独立段，每段内室外消火栓数量不宜超过5个",{"id":461,"libraryId":5,"type":9,"typeLabel":40,"stem":462,"options":463,"answer":31,"analysis":37},931713,"（2015真题）下列建筑中，室内采用临时高压消防给水系统时，必须设置高位消防水箱的是（ ）。",[464,466,468,470],{"key":20,"text":465,"correct":29},"建筑面积只为5000m2的单层丙类厂房",{"key":24,"text":467,"correct":29},"建筑面积为40000m2的4层丁类厂房",{"key":27,"text":469,"correct":29},"建筑面积为5000m2的2层办公楼",{"key":31,"text":471,"correct":22},"建筑面积为30000m2的3层商业中心",{"id":473,"libraryId":5,"type":9,"typeLabel":40,"stem":474,"options":475,"answer":31,"analysis":37},931714,"（2017真题）室外消火栓距建筑物外墙不宜小于（ ）m。",[476,477,478,480],{"key":20,"text":193,"correct":29},{"key":24,"text":195,"correct":29},{"key":27,"text":479,"correct":29},"6.0",{"key":31,"text":481,"correct":22},"5.0",{"id":483,"libraryId":5,"type":9,"typeLabel":40,"stem":484,"options":485,"answer":31,"analysis":37},931715,"（2017真题）单台消防水泵的设计压力和流量分别不大于（ ）时，消防泵组应在泵房内预留流量计和压力计接口。",[486,488,490,492],{"key":20,"text":487,"correct":29},"0.50MPa、25L\u002Fs",{"key":24,"text":489,"correct":29},"1.00MPa、25L\u002Fs",{"key":27,"text":491,"correct":29},"1.00MPa、20L\u002Fs",{"key":31,"text":493,"correct":22},"0.50MPa、20L\u002Fs",{"id":495,"libraryId":5,"type":9,"typeLabel":40,"stem":496,"options":497,"answer":20,"analysis":37},931716,"（2017真题）室内消火栓栓口动压大于()Mpa时,必须设置减压装置。",[498,500,502,504],{"key":20,"text":499,"correct":22},"0.70",{"key":24,"text":501,"correct":29},"0.30",{"key":27,"text":503,"correct":29},"0.35",{"key":31,"text":505,"correct":29},"0.50",{"id":507,"libraryId":5,"type":15,"typeLabel":16,"stem":508,"options":509,"answer":520,"analysis":37},931717,"（2018真题）某多层科研楼设有室内消防给水系统，其高位消防水箱进水管管径为 DN100。该高位消防水箱溢流管的下列设置方案中，正确的有()。",[510,512,514,516,518],{"key":20,"text":511,"correct":22},"溢流水管经排水沟与建筑排水管网连接",{"key":24,"text":513,"correct":29},"溢流水管上安装用于检修的闸阀",{"key":27,"text":515,"correct":29},"溢流管采用 DN150 的钢管",{"key":31,"text":517,"correct":29},"溢流管的喇叭口直径为 250mm",{"key":34,"text":519,"correct":22},"溢流水位低于进水管口的最低点 100mm","AE",{"id":522,"libraryId":5,"type":9,"typeLabel":40,"stem":523,"options":524,"answer":27,"analysis":37},931718,"（2019年真题）某小区设有3栋16层住宅，建筑高度均为49m。3栋住宅室内消火栓系统共用一套临时高压消防给水系统。该小区消火栓系统供水设施的下列设计方案中，错误的是（）",[525,527,529,531],{"key":20,"text":526,"correct":29},"高位消防水箱的有效容积为12m3",{"key":24,"text":528,"correct":29},"当该小区室外消火栓采用低压消防给水系统，并采用市政给水管网供水时，采用两路消防供水",{"key":27,"text":530,"correct":22},"高位消防水箱最低有效水位满足室内消火栓最不利点的静水压力不低于0.05MPa",{"key":31,"text":532,"correct":29},"水泵接合器在每栋住宅附近设置，且距室外消火栓30m",{"id":534,"libraryId":5,"type":15,"typeLabel":16,"stem":535,"options":536,"answer":547,"analysis":37},931719,"（2019年真题）某办公楼地上8层，建筑高度32m，室内消火栓采用临时高压消防给水系统，并设有稳压泵。该消防给水系统稳压泵的下列设计方案中，正确的有（）",[537,539,541,543,545],{"key":20,"text":538,"correct":29},"稳压泵不设置备用泵",{"key":24,"text":540,"correct":22},"稳压泵的设计流量不小于室内消火栓系统管网的正常液漏量和系统自动启动流量",{"key":27,"text":542,"correct":22},"稳压泵采用单吸多级离心泵",{"key":31,"text":544,"correct":29},"稳压泵的设计压力保持系统最不利点处室内消火栓在准工作状态时的静水压力为0.10MPa",{"key":34,"text":546,"correct":22},"稳压泵叶轮材质采用不锈钢","BCE",{"id":549,"libraryId":5,"type":9,"typeLabel":40,"stem":550,"options":551,"answer":31,"analysis":37},931720,"（2019年真题）某石化企业工艺装置区采用高压消防给水系统。该装置成根据设计流量经计算确定，且布置间距不应大于（）。",[552,554,556,558],{"key":20,"text":553,"correct":29},"110m",{"key":24,"text":555,"correct":29},"120m",{"key":27,"text":557,"correct":29},"150m",{"key":31,"text":559,"correct":22},"60m",{"id":561,"libraryId":5,"type":9,"typeLabel":40,"stem":562,"options":563,"answer":20,"analysis":37},931721,"（2019年真题）在某一甲类液体储罐防火堤外有7个室外消火栓，消火栓与该罐罐壁的最小距离分别为160m、110m、90m、60m、40m、30m和14m，上述室外消火栓中，有（）可计入该罐的室外消火栓设计数量。",[564,565,567,569],{"key":20,"text":391,"correct":22},{"key":24,"text":566,"correct":29},"7个",{"key":27,"text":568,"correct":29},"6个",{"key":31,"text":389,"correct":29},{"id":571,"libraryId":5,"type":9,"typeLabel":40,"stem":572,"options":573,"answer":31,"analysis":37},931722,"（2019年真题）某工业园区拟新建的下列4座建筑中，可不设置室内消火栓系统的是（）",[574,576,578,580],{"key":20,"text":575,"correct":29},"耐火等级为三级，占地面积为600㎡，建筑体积为2900m3的丁类仓库",{"key":24,"text":577,"correct":29},"耐火等级为四级，占地面积为800㎡，建筑体积为5100m3的戊类厂房",{"key":27,"text":579,"correct":29},"耐火等级为四级，占地面积为800㎡，建筑体积为5100m3的戊类仓库",{"key":31,"text":581,"correct":22},"耐火等级为三级，占地面积为600㎡，建筑体积为2900m3的丁类厂房",{"id":583,"libraryId":5,"type":15,"typeLabel":16,"stem":584,"options":585,"answer":596,"analysis":37},931723,"（2019年真题）某商场设有火灾自动报警系统和室内消火栓系统，商场屋顶设有高位消防水箱。根据现行国家标准《火灾自动报警系统设计规范》(GB50016) ，该商场室内消火栓系统的下列控制设计方案中，错误的有()。",[586,588,590,592,594],{"key":20,"text":587,"correct":22},"消火栓按钮的动作信号直接控制消火栓泵的启动",{"key":24,"text":589,"correct":22},"消防联动控制器处于自动状态时，高位消防水箱出水干管流量开关的动作信号不能直接联锁控制消火栓泵启动",{"key":27,"text":591,"correct":22},"消防联动控制器处于自动状态时，该控制器不能手动控制消火栓泵启动",{"key":31,"text":593,"correct":29},"消防联动控制器处于手动或自动状态，高位消防水箱出水干管流量开关的动作信号均能直接联锁控制消火栓泵启动",{"key":34,"text":595,"correct":29},"消防联动控制器处于手动状态时，该控制器不能联动控制消火栓泵启动","ABC",{"id":598,"libraryId":5,"type":9,"typeLabel":40,"stem":599,"options":600,"answer":27,"analysis":37},931724,"（2019年真题）5座单层丙类工业厂房从东至西一字排开成组布置建筑体积依次为1000m3、1500m3、3000m3、1800m3、 1200m3，厂房的耐火等级均为一级，上述厂房室外消火栓的设计流量不应小于（ ）。 建筑物室外消火栓设计流量",[601,603,604,605],{"key":20,"text":602,"correct":29},"15L\u002Fs",{"key":24,"text":375,"correct":29},{"key":27,"text":373,"correct":22},{"key":31,"text":377,"correct":29},{"id":607,"libraryId":5,"type":9,"typeLabel":40,"stem":608,"options":609,"answer":24,"analysis":37},931725,"（2019年真题）某6层宾馆，建筑高度为23m,建筑体积26000m3。设有消火栓系统和自动喷水灭火系统。该宾馆室外消火栓设计流量为30L\u002Fs, 室内消火栓设计流量为20L\u002Fs，自动喷水灭火系统设计流量为20L\u002Fs。 按上述涉及参数，该宾馆一次火灾的室内外消防用水量为（）",[610,612,613,615],{"key":20,"text":611,"correct":29},"504m3",{"key":24,"text":411,"correct":22},{"key":27,"text":614,"correct":29},"522m3",{"key":31,"text":616,"correct":29},"612m3",{"id":618,"libraryId":5,"type":9,"typeLabel":40,"stem":619,"options":620,"answer":20,"analysis":37},931726,"（2020年真题）某酒店室内消火栓系统的设计工作压力为1.0MPa，设置2台消火栓泵（一用一备），消火栓泵出水管上压力表最大量程至少应为（ ）MPa。",[621,623,625,626],{"key":20,"text":622,"correct":22},"2.5",{"key":24,"text":624,"correct":29},"0.5",{"key":27,"text":191,"correct":29},{"key":31,"text":627,"correct":29},"1.6",[629,632,635,638,641,644],{"id":9,"name":630,"category":7,"favorite":631},"领导干部任职前廉政法规知识测试题",92,{"id":633,"name":634,"category":7,"favorite":9},595,"建筑结构与设备",{"id":636,"name":637,"category":7,"favorite":9},715,"招标采购专业知识与法律法规",{"id":639,"name":640,"category":7,"favorite":9},848,"市政方向-通用基础",{"id":642,"name":643,"category":7,"favorite":8},534,"BIM工程师",{"id":645,"name":643,"category":7,"favorite":8},535]