[{"data":1,"prerenderedAt":-1},["ShallowReactive",2],{"q-934492":3},{"question":4,"library":26},{"id":5,"libraryId":6,"type":7,"typeLabel":8,"stem":9,"options":10,"answer":12,"analysis":25},934492,604,1,"单选题","高层建筑中的多功能厅设在三层以上时应符合的规定，以下不正确的是（ ）。",[11,15,19,22],{"key":12,"text":13,"correct":14},"A","一个厅室的使用面积不宜超过500m2",true,{"key":16,"text":17,"correct":18},"B","一个厅、室的疏散门不应少于两个",false,{"key":20,"text":21,"correct":18},"C","应设置自动报警系统",{"key":23,"text":24,"correct":18},"D","应设置自动灭火系统","参考《建规》5.4.8：“建筑内的会议厅、多功能厅等人员密集的场所，宜布置在首层、二层或三层。设置在三级耐火等级的建筑内时，不应布置在三层及以上楼层。确需布置在一、二级耐火等级建筑的其他楼层时，应符合下列规定：1一个厅、室的疏散门不应少于2个，且建筑面积不宜大于400m2：2设置在高层建筑内时，应设置火灾自动报警系统和自动喷水灭火系统等自动灭火系统。”故A错误。",{"id":6,"name":27,"category":28,"favorite":29},"消防安全技术实务(一级)","建筑工程",0]